Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Off-the-shelf wearable sensing devices for personalized thermal comfort models: A systematic review on their use in scientific research

  • Costantino, Andrea|||0000-0003-4298-432X
  • Ferrara, Maria
  • Arnesano, Marco
  • Fabrizio, Enrico
[EN] Human thermal comfort depends on objective variables -related to the environment- and to subjective variables, related to physiological conditions. While the former are relatively easy to be measured, the latter are difficult to be investigated since differ from person to person and they are characterized by sudden variations over time. The recent spread of off-the-shelf wearable devices for monitoring bio-signals has considerably facilitate this challenging task. The aim of this work is to provide a detailed framework about the use of off-the-shelf wearable devices for thermal comfort investigations. A systematic review of 35 scientific papers -selected over 302 results from the initial database query- was performed. The results highlight that wristbands (mainly, Empatica E4 and Fitbit), headbands (i.e., Muse 2), chest bands (mainly, BioHarness 3.0 and Polar H7), miniature data loggers (i.e., iButton), and activity sensors (i.e., Move 3) were the off-the-shelf devices whose use is predominant in thermal comfort investigations. Those devices were adopted for different purposes, namely finding correlations between physiological signals and thermal sensations, training and/or validating thermal comfort models, improving data acquisition, and controlling HVAC systems. The proposed framework could represent a solid background for future investigations which should focus on two main research streams. The first one should aim at strengthening the knowledge about statistical correlations between thermal sensations and physiological signals, as well as defining standardized procedures for the model development and validation. The second research stream should aim at integrating off-the-shelf wearable devices and personalized thermal comfort models into HVAC control systems., The research has been funded by the Italian Ministry of Research through the NEXT. COM (Prot. 20172FSCH4) "Towards the NEXT generation of Multiphysics and multidomain environmental COMfort models: theory elaboration and validation experiment" project, within the PRIN 2017 program.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Analysis of thermal energy storage tanks and PV panels combinations in different buildings controlled through model predictive control

  • Tarragona, Joan
  • Pisello, Anna Laura
  • Fernández, César
  • Cabeza, Luisa F.
  • de Gracia, Álvaro
  • Payá-Herrero, Jorge|||0000-0003-2663-3191
  • Marchante-Avellaneda, Javier|||0000-0001-5680-5033
[EN] The present study analyses the performance of a heating system controlled by a model predictive control strategy, where the impact of different combinations of thermal energy storage tank volumes and installed PV power capacities are analysed. The novelty of the paper lies in studying both economic and energy impacts of each equipment combination in different locations, buildings, and indoor occupancy schedules. The payback period, the reduction of the electricity grid consumption, and the behaviour of the coefficient of performance of the heat pump are studied in detail for all cases. Results point out that from an economic point of view, to invest in a thermal energy storage tank provides shorter payback periods in comparison to scenarios with PV panels, due to the high price of the solar elements. However, the energy performance analysis highlighted that the use of PV panels contributes to achieve up to 34%, 54%, and 90% of reduction of the electricity grid consumption in Helsinki, Strasbourg, and Athens, respectively. Finally, it is worth noting that the increase of the thermal energy storage volume improves the coefficient of performance of the heat pump., This work was partially funded by the Ministerio de Ciencia, Innovacion y Universidades de Espana (RTI2018-093849-B-C31-MCIU/AEI/FEDER, UE) and the Agencia Estatal de Investigacion (AEI) (RED2018-102431-T) . The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2017 SGR 1537) . GREiA is a certified TECNIO agent in the category of technology developers from the Government of Catalonia. This work is partially supported by ICREA under the ICREA Academia programme. A.L. Pisello's acknowledgements are due to the National Ministry of Research for supporting NEXT.COM project under the framework of PRIN 2017 (cod. 20172FSCH4_002) and the IEA EBC Annex 79 "Occupant-centric building design and operation" for inspiring human-centric research.