Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

First Images of a Three-layer compton Telescope prototype for Treatment Monitoring in hadron Therapy

  • Llosá, Gabriela
  • Trovato, Marco
  • Etxebeste, Ane
  • Muñoz, Enrique
  • Lacasta, C.
  • Rafecas, Magdalena
  • Solaz, Carles
  • Solevi, Paola
  • Barrio-Toala, John|||0000-0001-5181-2146
  • Oliver-Guillén, José Francisco|||0000-0002-8585-9345
[EN] A Compton telescope for dose monitoring in hadron therapy is under development at IFIC. The system consists of three layers of LaBr3 crystals coupled to silicon photomulti-plier arrays. Na-22 sources have been successfully imaged reconstructing the data with an ML-EM code. Calibration and temperature stabilization are necessary for the prototype operation at low coincidence rates. A spatial resolution of 7.8 mm FWHM has been obtained in the first imaging tests., This work was supported in part by the European Commissions 7th Framework Programme through the ENVISION (G. A. num 241851) project and the Marie Curie ITN ENTERVISION (G. A. num 264552), by the Spanish Ministerio de Economia y Competitividad (FPA2010-14891, FIS2011-14585-E, and FPA2014-53599-R), the UVEG (UV-INV-PRECOMP12-80755), and the Generalitat Valenciana (GV/2013/133 and GVISIC/ 2012/020). Group members are supported by Ramón y Cajal, UVEG Atraccio de Talent, and Generalitat Valenciana contracts.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

First Compton telescope prototype based on continuous LaBr3-SiPM detectors

  • Llosá, G.
  • Cabello, J.
  • Callier, S.
  • Gillam, J.E.
  • Lacasta, C.
  • Rafecas, M.
  • Raux, L.
  • Solaz, C.
  • Stankova, V.
  • de la Taille, C.
  • Trovato, M.
  • Barrio-Toala, John|||0000-0001-5181-2146
[EN] A first prototype of a Compton camera based on continuous scintillator crystals coupled to silicon photomultiplier (SiPM) arrays has been successfully developed and operated. The prototype is made of two detector planes. The first detector is made of a continuous 16 x 18 x 5 mm(3) LaBr3 crystal coupled to a 16-elements SiPM array. The elements have a size of 3 x 3 mm (3) in a 4.5 x 4.05 mm(2) pitch. The second detector, selected by availability, consists of a continuous 16 x 18 x 5 mm(3) LYSO crystal coupled to a similar SiPM array. The SPIROC1 ASIC is employed in the readout electronics. Data have been taken with a Na-22 source placed at different positions and images have been reconstructed with the simulated one-pass list-mode (SOPL) algorithm. Detector development for the construction of a second prototype with three detector planes is underway. LaBr3 crystals of 32 x 36 mm(2) size and 5/10 mm thickness have been acquired and tested with a PMT. The resolution obtained is 3.5% FWHM at 511 keV. Each crystal will be coupled to four MPPC arrays. Different options are being tested for the prototype readout., This work was supported in part by the ENVISION project (Grant Agreement num 241851), and ENTERVISION ITN (Grant Agreement num 264552), funded by the European Commission under FP7, and through a Research project of the Spanish Ministerio de Economia y Competitividad/Plan Nacional de IþDþi (FPA2010-14891). Several group members are supported through the Juan de la Cierva (CSIC), JAE-DOC (CSIC) and Atraccio de Talent (UV) programs.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

First Images of a Three-Layer Compton Telescope Prototype for Treatment Monitoring in Hadron Therapy

  • Llosá, Gabriela
  • Trovato, Marco
  • Barrio Toala, J.
  • Etxebeste, Ane
  • Muñoz, Enrique
  • Lacasta Llácer, Carlos
  • Oliver, Josep F.
  • Rafecas López, Magdalena
  • Solaz, Carles
  • Solevi, Paola
A Compton telescope for dose monitoring in hadron therapy is under development at IFIC. The system consists of three layers of LaBr3 crystals coupled to silicon photomultiplier arrays. 22Na sources have been successfully imaged reconstructing the data with an ML-EM code. Calibration and temperature stabilization are necessary for the prototype operation at low coincidence rates. A spatial resolution of 7.8 mm FWHM has been obtained in the first imaging tests., This work was supported in part by the European Commissions 7th Framework Programme through the ENVISION (G. A. num 241851) project and the Marie Curie ITN ENTERVISION (G. A. num 264552), by the Spanish Ministerio de Economia y Competitividad (FPA2010-14891, FIS2011-14585-E, and FPA2014-53599-R), the UVEG (UV-INV-PRECOMP12-80755), and the Generalitat Valenciana (GV/2013/133 and GVISIC/2012/020). Group members are supported by Ramón y Cajal, UVEG Atraccio de Talent, and Generalitat Valenciana contracts., Peer reviewed, Peer Reviewed