First Images of a Three-layer compton Telescope prototype for Treatment Monitoring in hadron Therapy

  • Llosá, Gabriela
  • Trovato, Marco
  • Etxebeste, Ane
  • Muñoz, Enrique
  • Lacasta, C.
  • Rafecas, Magdalena
  • Solaz, Carles
  • Solevi, Paola
  • Barrio-Toala, John|||0000-0001-5181-2146
  • Oliver-Guillén, José Francisco|||0000-0002-8585-9345
[EN] A Compton telescope for dose monitoring in hadron therapy is under development at IFIC. The system consists of three layers of LaBr3 crystals coupled to silicon photomulti-plier arrays. Na-22 sources have been successfully imaged reconstructing the data with an ML-EM code. Calibration and temperature stabilization are necessary for the prototype operation at low coincidence rates. A spatial resolution of 7.8 mm FWHM has been obtained in the first imaging tests., This work was supported in part by the European Commissions 7th Framework Programme through the ENVISION (G. A. num 241851) project and the Marie Curie ITN ENTERVISION (G. A. num 264552), by the Spanish Ministerio de Economia y Competitividad (FPA2010-14891, FIS2011-14585-E, and FPA2014-53599-R), the UVEG (UV-INV-PRECOMP12-80755), and the Generalitat Valenciana (GV/2013/133 and GVISIC/ 2012/020). Group members are supported by Ramón y Cajal, UVEG Atraccio de Talent, and Generalitat Valenciana contracts.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

First tests in the application of silicon photomultiplier arrays to dose monitoring in hadron therapy

  • Llosá, G.
  • Lacasta, C.
  • Callier, S.
  • Raux, L.
  • de la Taille, C.
  • Barrio-Toala, John|||0000-0001-5181-2146
[EN] A detector head composed of a continuous LaBr3 crystal coupled to a silicon photomultiplier array has been mounted and tested, for its use in a Compton telescope for dose monitoring in hadron therapy. The LaBr3 crystal has 16 mm x 18 mm x 5 mm size, and it is surrounded with reflecting material in five faces. The SiPM array has 16 (4 x 4) elements of 3 mm x 3 mm size. The SPIROC1 ASIC has been employed as readout electronics. The detector shows a linear behavior up to 1275 keV. The energy resolution obtained at 511 keV is 7% FWHM, and it varies as one over the square root of the energy up to the energies tested. The variations among the detector channels are within 12%. A preliminary measurement of the timing resolution gives 7 ns FWHM. The spatial resolution obtained with the center of gravity method is 1.2 mm FWHM. The tests performed confirm the correct functioning of the detector., Part of this work has been carried out within the ENVISION project that is co-funded by the European Commission under FP7 Grant Agreement no. 241851.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

First Compton telescope prototype based on continuous LaBr3-SiPM detectors

  • Llosá, G.
  • Cabello, J.
  • Callier, S.
  • Gillam, J.E.
  • Lacasta, C.
  • Rafecas, M.
  • Raux, L.
  • Solaz, C.
  • Stankova, V.
  • de la Taille, C.
  • Trovato, M.
  • Barrio-Toala, John|||0000-0001-5181-2146
[EN] A first prototype of a Compton camera based on continuous scintillator crystals coupled to silicon photomultiplier (SiPM) arrays has been successfully developed and operated. The prototype is made of two detector planes. The first detector is made of a continuous 16 x 18 x 5 mm(3) LaBr3 crystal coupled to a 16-elements SiPM array. The elements have a size of 3 x 3 mm (3) in a 4.5 x 4.05 mm(2) pitch. The second detector, selected by availability, consists of a continuous 16 x 18 x 5 mm(3) LYSO crystal coupled to a similar SiPM array. The SPIROC1 ASIC is employed in the readout electronics. Data have been taken with a Na-22 source placed at different positions and images have been reconstructed with the simulated one-pass list-mode (SOPL) algorithm. Detector development for the construction of a second prototype with three detector planes is underway. LaBr3 crystals of 32 x 36 mm(2) size and 5/10 mm thickness have been acquired and tested with a PMT. The resolution obtained is 3.5% FWHM at 511 keV. Each crystal will be coupled to four MPPC arrays. Different options are being tested for the prototype readout., This work was supported in part by the ENVISION project (Grant Agreement num 241851), and ENTERVISION ITN (Grant Agreement num 264552), funded by the European Commission under FP7, and through a Research project of the Spanish Ministerio de Economia y Competitividad/Plan Nacional de IþDþi (FPA2010-14891). Several group members are supported through the Juan de la Cierva (CSIC), JAE-DOC (CSIC) and Atraccio de Talent (UV) programs.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Detector characterization and first coincidence tests of a Compton telescope based onLaBr3 crystals and SiPMs

  • Llosá, G.
  • Cabello, J.
  • Crespo, A.
  • Lacasta, C.
  • Rafecas, M.
  • Callier, S.
  • de la Taille, C.
  • Raux, L.
  • Barrio-Toala, John|||0000-0001-5181-2146
[EN] A Compton telescope for dose monitoring in hadron therapy consisting of several layers of continuous LaBr3 crystals coupled to silicon photomultiplier (SiPM) arrays is under development within the ENVISION project. In order to test the possibility of employing such detectors for the telescope, a detector head consisting of a continuous 16 mm x 18 mm x 5 mm LaBr3 crystal coupled to a SiPM array has been assembled and characterized, employing the SPIROC1 ASIC as readout electronics. The best energy resolution obtained at 511 key is 6.5% FWHM and the timing resolution is 3.1 ns FWHM. A position determination method for continuous crystals is being tested, with promising results. In addition, the detector has been operated in time coincidence with a second detector layer, to determine the coincidence capabilities of the system. The first tests are satisfactory, and encourage the development of larger detectors that will compose the telescope prototype., Part of this work has been carried out within the ENVISION project, that is co-funded by the European Commission under FP7 Grant Agreement No. 241851.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Performance of VATA64HDR16 ASIC for medical physics applications based on continuous crystals and SiPMs

  • Barrio-Toala, John|||0000-0001-5181-2146
  • Oliver-Guillén, José Francisco|||0000-0002-8585-9345
  • Etxebeste, A.
  • Lacasta, C.
  • Muñoz, E.
  • Solaz, C.
  • Llosá, G.
[EN] Detectors based on Silicon Photomultipliers (SiPMs) coupled to continuous crystals are being tested in medical physics applications due to their potential high resolution and sensitivity. To cope with the high granularity required for a very good spatial resolution, SiPM matrices with a large amount of elements are needed. To be able to read the information coming from each individual channel, dedicated ASICs are employed. The VATA64HDR16 ASIC is a 64-channel, charge-sensitive amplifier that converts the collected charge into a proportional current or voltage signal. A complete assessment of the suitability of that ASIC for medical physics applications based on continuous crystals and SiPMs has been carried out. The input charge range is linear from 20 pC up to 55 pC. The energy resolution obtained at 511 keV is 10% FWHM with a LaBr3 crystal and 16% FWHM with a LYSO crystal. A coincidence timing resolution of 24 ns FWHM is obtained with two LYSO crystals., This work was supported in part by the European Commission's 7th Framework Programme through the ENVISION project (G. A. num 241851), by the Spanish Ministerio de Economia y Competitividad (FPA2014-53599-R), the UVEG (UV-INV-PRECOMP12-80755) and the Generalitat Valenciana (GV/2013/133 and GVISIC/2012/020). Group members are supported by Ramon y Cajal, UVEG Atraccio de Talent and Generalitat Valenciana contracts.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Experimental results with a Compton telescope prototype: MACACO II

  • Borja-Lloret, Marina
  • Barrientos, Luis
  • Barrio Toala, J.
  • Bernabéu, José
  • Dendooven, P.
  • García López, J.
  • Jiménez-Ramos, M. C.
  • Lacasta Llácer, Carlos
  • Muñoz, Enrique
  • Oliver, Josep F.
  • Ozoemelan, I.
  • Ros García, Ana
  • Roser, J.
  • Senra, C.
  • Solaz, Carles
  • Llosá, Gabriela
Trabajo presentado en el 17th Annual Meeting and Training, celebrado en Caen (Francia) del 1 al 3 de julio de 2019, Purpose Real-time monitoring is still a challenge in hadrontherapy. With this aim, a Compton telescope prototype (MACACO) has been developed by the IRIS group at IFIC-Valencia within the European project ENVISION. The second prototype MACACO II is an upgrade developed with the purpose of enhancing its performance. Material and Methods MACACO II consists of three layers of LaBr3 monolithic crystals coupled to silicon photomultiplier (SiPM) arrays. New crystals have been coupled to 8x8 pixel SiPM arrays from Hamamatsu Photonics (S13361-3050AE-08). Moreover, an improved image reconstruction code including an accurate model for the sensitivity matrix has been implemented. The telescope has been characterized in the laboratory with 22Na and 152Eu sources and tested in two accelerator centres. The first test took place at CNA (Sevilla) with a 18 MeV proton beam impinging on a graphite target in order to produce 4.4 MeV gamma rays. A second test was held in KVI-CART (Groningen) with a 150 MeV proton beam hitting a PMMA target. Monte Carlo simulations have been carried out with GATE V 7.0. Results In the laboratory, the energy resolution has been improved and an angular resolution of 4.6° has been achieved, which together with the improved reconstruction code, have led to a better image quality. The efficiency measured with two planes in coincidence at 1275 keV is 1.0x10-3. Monte Carlo simulations result in a good correlation with the experimental parameters. Regarding the In-beam experiments, two target positions separated by 5 mm have been reconstructed from the CNA test-beam. Furthermore, KVI-CART test-beam results show that Bragg distribution correlates to the PMMA position. Conclusions MACACO II has shown a better performance than the previous prototype. The testbeam results have demonstrated the ability to reconstruct different positions. Further improvements are ongoing in order to achieve the required performance for the application., This work was supported in part by the European Commission's 7th Framework Programme through the ENVISION project (G. A. num 241851), by the Spanish Ministerio de Ciencia, Innovación y Universidades (FPA2014-53599-R, FPA2017-85611-R and IFIC's Center of Excellence Severo Ochoa SEV-2014-0398) and by H2020 ENSAR2- MediNet (project number 654002). Group members are supported by Ramón y Cajal, UVEG Atraccio de Talent and Spanish Ministerio de Ciencia, Innovación y Universidades.