Skip to main content

INVESTIGACION DE TECNICAS COMPTON PARA APLICACIONES MEDICAS.

FPA2017-85611-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

First results with MACACO II: second prototype of a Compton telescope

  • Ros García, Ana
  • Barrientos, Luis
  • Barrio Toala, J.
  • Bernabéu, José
  • Borja-Lloret, Marina
  • Dendooven, P.
  • Etxebeste, Ane
  • Gabarda, L.
  • García López, J.
  • Jiménez-Ramos, M. C.
  • Lacasta Llácer, Carlos
  • Marco Hernández, Ricardo
  • Muñoz, Enrique
  • Oliver, Josep F.
  • Ozoemelan, I.
  • Praena, Javier
  • Roser, J.
  • Senra, C.
  • Solaz, Carles
  • Llosá, Gabriela
Trabajo presentado en el IEEE Nuclear Science Symposium and Medical Imaging Conference, celebrado en Sydney (Australia), del 10 al 17 de noviembre de 2018, The IRIS group at IFIC Valencia is developing a three-layer Compton camera for treatment monitoring in ion beam therapy. The system is composed of three detector planes, each made of a LaBr3 monolithic crystal coupled to SiPM arrays. The first prototype (MACACO) was fully characterised in the laboratory and in beam tests demonstrating the feasibility of the proposed technology. A second prototype (MACACO II), described in this work, is currently being developed to improve performance. The SiPM arrays have been replaced by newer models, leading to an improved detector energy resolution which translates into a higher spatial resolution of the telescope. A new coincidence board allows acquisition of data with any two or all three detectors simultaneously. In addition, the image reconstruction code has been improved with an accurate model of the sensitivity matrix. The device has also been tested in two accelerator facilities. The first involved a proton beam of 18 MeV impinging a graphite target. The results allowed the successful reconstruction of two target positions separated by 5 mm. The second test beam used protons of 150 MeV impinging on a PMMA target. Preliminary analysis results show prompt-gamma energy spectra as expected for these proton energies. Analysis of this data is ongoing, with the aim of reconstructing the Bragg peak profilein the PMMA target. Further improvements to the readout electronics are also underway., This work was supported in part by the European Commission's 7th Framework Programme through the ENVISION project (G. A. num 241851) and by the Spanish Ministerio de Ciencia, Innovación y Universidades (FPA2014-53599-R, FPA2017-85611-R and IFIC's Center of Excellence Severo Ochoa SEV-2014-0398). Group members are supported by Ramón y Cajal, UVEG Atraccio de Talent and Generalitat Valenciana contracts., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Experimental results with a Compton telescope prototype: MACACO II

  • Borja-Lloret, Marina
  • Barrientos, Luis
  • Barrio Toala, J.
  • Bernabéu, José
  • Dendooven, P.
  • García López, J.
  • Jiménez-Ramos, M. C.
  • Lacasta Llácer, Carlos
  • Muñoz, Enrique
  • Oliver, Josep F.
  • Ozoemelan, I.
  • Ros García, Ana
  • Roser, J.
  • Senra, C.
  • Solaz, Carles
  • Llosá, Gabriela
Trabajo presentado en el 17th Annual Meeting and Training, celebrado en Caen (Francia) del 1 al 3 de julio de 2019, Purpose Real-time monitoring is still a challenge in hadrontherapy. With this aim, a Compton telescope prototype (MACACO) has been developed by the IRIS group at IFIC-Valencia within the European project ENVISION. The second prototype MACACO II is an upgrade developed with the purpose of enhancing its performance. Material and Methods MACACO II consists of three layers of LaBr3 monolithic crystals coupled to silicon photomultiplier (SiPM) arrays. New crystals have been coupled to 8x8 pixel SiPM arrays from Hamamatsu Photonics (S13361-3050AE-08). Moreover, an improved image reconstruction code including an accurate model for the sensitivity matrix has been implemented. The telescope has been characterized in the laboratory with 22Na and 152Eu sources and tested in two accelerator centres. The first test took place at CNA (Sevilla) with a 18 MeV proton beam impinging on a graphite target in order to produce 4.4 MeV gamma rays. A second test was held in KVI-CART (Groningen) with a 150 MeV proton beam hitting a PMMA target. Monte Carlo simulations have been carried out with GATE V 7.0. Results In the laboratory, the energy resolution has been improved and an angular resolution of 4.6° has been achieved, which together with the improved reconstruction code, have led to a better image quality. The efficiency measured with two planes in coincidence at 1275 keV is 1.0x10-3. Monte Carlo simulations result in a good correlation with the experimental parameters. Regarding the In-beam experiments, two target positions separated by 5 mm have been reconstructed from the CNA test-beam. Furthermore, KVI-CART test-beam results show that Bragg distribution correlates to the PMMA position. Conclusions MACACO II has shown a better performance than the previous prototype. The testbeam results have demonstrated the ability to reconstruct different positions. Further improvements are ongoing in order to achieve the required performance for the application., This work was supported in part by the European Commission's 7th Framework Programme through the ENVISION project (G. A. num 241851), by the Spanish Ministerio de Ciencia, Innovación y Universidades (FPA2014-53599-R, FPA2017-85611-R and IFIC's Center of Excellence Severo Ochoa SEV-2014-0398) and by H2020 ENSAR2- MediNet (project number 654002). Group members are supported by Ramón y Cajal, UVEG Atraccio de Talent and Spanish Ministerio de Ciencia, Innovación y Universidades.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Results with MACACO II: A Compton telescope for hadron therapy monitoring

  • Barrientos, Luis
  • Borja-Lloret, Marina
  • Dendooven, P.
  • García López, J.
  • Jiménez-Ramos, M. C.
  • Lacasta Llácer, Carlos
  • Muñoz, Enrique
  • Oliver, Josep F.
  • Ozoemelan, I.
  • Ros García, Ana
  • Roser, J.
  • Senra, C.
  • Solaz, Carles
  • Viegas, R.
  • Llosá, Gabriela
Trabajo presentado en la 24th International Conference on Medical Physics, celebrada en Santiago de Chile, del 8 al 11 de septiembre, Hadron therapy (HT) is a technique used in cancer treatment that consists in the irradiation of tumours using light ions or protons instead of photons. HT treatment monitoring in real-time is one of the main challenges addressed nowadays. The IRIS group (http://ific.uv.es/iris) at IFIC-Valencia is developing a Compton telescope with this purpose. The system is made of three LaBr3 detector planes coupled to silicon photomultipliers (SiPMs). A first prototype (MACACO: Medical Applications CompAct COmpton camera) was successfully developed, with promising results. A second version has been developed with the aim of improving the system performance, including new detectors for the first two planes and an improved image reconstruction code, improving significantly the performance tests in laboratory and accelerator facilities. The performance improvement of MACACO II was verified through experimental tests. In addition, Monte Carlo simulations were made with GATE v 7.0 getting a good correlation with the experimental measurements. In this poster we present results corresponding to the two-layer layout with the new detectors., This work has received funding from the Spanish Ministerio de Ciencia, Innovación y Universidades (FPA2017-85611-R and IFIC's Center of Excellence Severo Ochoa SEV-2014-0398) and from EC H2020 ENSAR2/MediNet (project number 654002)
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Contribución de congreso (ConferenceOutput)

Experimental characterization of MACACO III Compton telescope for hadron therapy treatment monitoring, Caracterización del telescopio Compton MACACO III para monitorización de terapia hadrónica

  • Barrientos, Luis
  • Borja-Lloret, Marina
  • Casaña, José Vicente
  • García López, J.
  • Hueso-González, F.
  • Jiménez-Ramos, M. C.
  • Lacasta Llácer, Carlos
  • Muñoz, Enrique
  • Ros García, Ana
  • Roser, J.
  • Senra, C.
  • Solaz, Carles
  • Viegas, R.
Trabajo presentado a las Jornadas de Física Médica, organizadas por la Real Sociedad Española de Física y el IFIC a través de la instalación de Física Médica IFIMED, celebradas virtualmente del 14 al 15 de diciembre de 2020., La terapia hadrónica es una técnica de tratamiento del cáncer consistente en la irradiación de tumores con protones u otros iones ligeros. El uso de esta técnica se ha incrementado por su ventaja de maximización de la dosis depositada sobre un tumor y de reducción de toxicidad del tratamiento comparado con la radioterapia convencional. Sin embargo, una de sus desventajas es la dificultad en la monitorización del rango del haz. Las cámaras Compton han resurgido como posibles candidatas para la monitorización de la terapia hadrónica, mediante la detección de los fotones producidos en la desexcitación de núcleos de los tejidos irradiados.El grupo IRIS del IFIC en Valencia se encuentra desarrollando un prototipo de una cámara Compton con la finalidad de ser empleada en monitorización de la terapia hadrónica. El prototipo MACACO (Medical Applications CompAct COmpton camera) se compone de cristales centelleadores de LaBr3 acoplados a una matriz de fotomultiplicadores de silicio. Con la finalidad de mejorar las prestaciones del prototipo, se ha construido una tercera versión que presenta un rendimiento mejorado respecto de sus predecesores. Los nuevos detectores de MACACO III se componen de cristales continuos de LaBr3 de 25,8 x 25,8 mm2 y 5 mm. El sistema de lectura AliVATA, desarrollado por el grupo, opera el ASIC VATA64HDR16 utilizado como electrónica de lectura. La caracterización de los detectores en el laboratorio se ha realizado utilizando fuentes radiactivas de 22Na, 152Eu y 137Cs. El mejor valor de resolución energética obtenido ha sido de 4.8 % FWHM a 662 keV, resolución angular de 6.0° FWHM a 1275 keV y eficiencia de detección en coincidencias de 1 x 10−3 a 1275 keV. A partir de los datos experimentales se han reconstruido imágenes de una fuente puntual de 22Na seleccionando eventos dobles y triples. El código de reconstrucción de MACACO III produce imágenes cuatridimensionales (energía y posición) usando eventos dobles o triples. Imágenes con la combinación de estos dos tipos de eventos ha sido recientemente conseguida. La FWHM de las imágenes reconstruidas fue de 2.4 mm y 3.3 mm FWHM a 1275 keV respectivamente a una distancia de la fuente de 70 mm. Con la finalidad de reproducir los resultados experimentales, MACACO III ha sido simulado en GATE v8.2 utilizando el módulo CCMod, obteniendo una buena correlación con los datos experimentales. MACACO III también ha sido caracterizado en aceleradores, con el fin de evaluar su respuesta en escenarios más realistas. Recientemente se ha testeado en el CNA (Sevilla) en un haz de protones de 18 MeV sobre un blanco de grafito. Los datos experimentales fueron tomados con el blanco en distintas posiciones y diferentes intensidades de haz. Imágenes con dos y tres planos fueron reconstruidas exitosamente en cada caso pudiendo distinguir distancias de 1 mm de separación del blanco. Futuras mejoras y pruebas en centros clínicos están en curso para alcanzar las prestaciones requeridas para la aplicación., This work has received funding from the Spanish Ministerio de Ciencia e Innovación (PID2019-110657RB-I00, FPA2017-85611-R and SEV-2014-0398), from Generalitat Valenciana (AICO/2019/070), from CSIC PIC 2018 programme (N2018FR0032) and from European Commission H2020 ENSAR2-MediNet (project number 654002). Group members are supported by Ramón y Cajal, SEJI and GENT programmes, UVEG Atracció de Talent, Generalitat Valenciana and Spanish Ministerio de Universidades FPU predoctoral contracts, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Proton range verification with MACACO II Compton camera enhanced by a neural network for event selection

  • Muñoz, Enrique
  • Ros, A.
  • Borja-Lloret, Marina
  • Barrio, John
  • Dendooven, P.
  • Oliver, Josep F.
  • Ozoemelam, I.
  • Roser, J.
  • Llosá, Gabriela
The applicability extent of hadron therapy for tumor treatment is currently limited by the lack of reliable online monitoring techniques. An active topic of investigation is the research of monitoring systems based on the detection of secondary radiation produced during treatment. MACACO, a multi-layer Compton camera based on LaBr scintillator crystals and SiPMs, is being developed at IFIC-Valencia for this purpose. This work reports the results obtained from measurements of a 150 MeV proton beam impinging on a PMMA target. A neural network trained on Monte Carlo simulations is used for event selection, increasing the signal to background ratio before image reconstruction. Images of the measured prompt gamma distributions are reconstructed by means of a spectral reconstruction code, through which the 4.439 MeV spectral line is resolved. Images of the emission distribution at this energy are reconstructed, allowing calculation of the distal fall-off and identification of target displacements of 3 mm.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

CCMod: A GATE module for Compton camera imaging simulation

  • Etxebeste, Ane
  • Dauvergne, D.
  • Fontana, M.
  • Létang, J.M.
  • Llosá, Gabriela
  • Muñoz, Enrique
  • Oliver, Josep F.
  • Testa, Etienne
  • Sarrut, D.
Compton cameras are gamma-ray imaging systems which have been proposed for a wide variety of applications such as medical imaging, nuclear decommissioning or homeland security. In the design and optimization of such a system Monte Carlo simulations play an essential role. In this work, we propose a generic module to perform Monte Carlo simulations and analyses of Compton Camera imaging which is included in the open-source GATE/Geant4 platform. Several digitization stages have been implemented within the module to mimic the performance of the most commonly employed detectors (e.g. monolithic blocks, pixelated scintillator crystals, strip detectors...). Time coincidence sorter and sequence coincidence reconstruction are also available in order to aim at providing modules to facilitate the comparison and reproduction of the data taken with different prototypes. All processing steps may be performed during the simulation (on-the-fly mode) or as a post-process of the output files (offline mode). The predictions of the module have been compared with experimental data in terms of energy spectra, angular resolution, efficiency and back-projection image reconstruction. Consistent results within a 3-sigma interval were obtained for the energy spectra except for low energies where small differences arise. The angular resolution measure for incident photons of 1275 keV was also in good agreement between both data sets with a value close to 13°. Moreover, with the aim of demonstrating the versatility of such a tool the performance of two different Compton camera designs was evaluated and compared., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A spectral reconstruction algorithm for two-plane Compton cameras

  • Muñoz, Enrique
  • Barrientos, Luis
  • Bernabeu, Jose
  • Borja-Lloret, Marina
  • Llosá, Gabriela
  • Ros, A.
  • Roser, J.
  • Oliver, Francisco Javier
One factor limiting the current applicability extent of hadron therapy is the lack of a reliable method for real time treatment monitoring. The use of Compton imaging systems as monitors requires the correct reconstruction of the distribution of prompt gamma productions during patient irradiation. In order to extract the maximum information from all the measurable events, we implemented a spectral reconstruction method that assigns to all events a probability of being either partial or total energy depositions. The method, implemented in a list-mode maximum likelihood expectation maximization algorithm, generates a four dimensional image in the joint spatial-spectral domain, in which the voxels containing the emission positions and energies are obtained. The analytical model used for the system response function is also employed to derive an analytical expression for the sensitivity, which is calculated via Monte Carlo integration. The performance of the method is evaluated through reconstruction of various experimental and simulated sources with different spatial and energy distributions. The results show that the proposed method can recover the spectral and spatial information simultaneously, but only under the assumption of ideal measurements. The analysis of the Monte Carlo simulations has led to the identification of two important degradation sources: the mispositioning of the gamma interaction point and the missing energy recorded in the interaction. Both factors are related to the high energy transferred to the recoil electrons, which can travel far from the interaction point and even escape the detector. These effects prevent the direct application of the current method in more realistic scenarios. Nevertheless, experimental point-like sources have been accurately reconstructed and the spatial distributions and spectral emission of complex simulated phantoms can be identified.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

MACACO II test-beam with high energy photons

  • Ros García, A.
  • Barrio, John
  • Etxebeste, A.
  • García López, J
  • Jiménez-Ramos, M. C.
  • Lacasta LLácer, Carlos
  • Muñoz, Enrique
  • Oliver, Josep F.
  • Roser, J.
  • Llosá, Gabriela
The IRIS group at IFIC Valencia is developing a three-layer Compton camera for treatment monitoring in proton therapy. The system is composed of three detector planes, each made of a [Formula: see text] monolithic crystal coupled to a SiPM array. Having obtained successful results with the first prototype (MACACO) that demonstrated the feasibility of the proposed technology, a second prototype (MACACO II) with improved performance has been developed, and is the subject of this work. The new system has an enhanced detector energy resolution which translates into a higher spatial resolution of the telescope. The image reconstruction method has also been improved with an accurate model of the sensitivity matrix. The device has been tested with high energy photons at the National Accelerator Centre (CNA, Seville). The tests involved a proton beam of 18 MeV impinging on a graphite target, to produce 4.4 MeV photons. Data were taken at different system positions of the telescope with the first detector at 65 and 160 mm from the target, and at different beam intensities. The measurements allowed successful reconstruction of the photon emission distribution at two target positions separated by 5 mm in different telescope configurations. This result was obtained both with data recorded in the first and second telescope planes (two interaction events) and, for the first time in beam experiments, with data recorded in the three planes (three interaction events)., This work has received funding from the Spanish Ministerio de Ciencia, Innovaci´on y Universidades (FPA2017-85611-R and IFIC’s Center of Excellence Severo Ochoa SEV-2014-0398) and from European Comission H2020 ENSAR2-MediNet (G.A. number 654002). Group members are supported by Ram´on y Cajal, Severo Ochoa Excellence postdoctoral contract, UVEG Atracci´o de Talent and Generalitat Valenciana contracts., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Performance evaluation of MACACO II Compton camera

  • Barrientos, Luis
  • Borja-Lloret, Marina
  • Etxebeste, A.
  • Muñoz, Enrique
  • Oliver, Francisco Javier
  • Ros García, Ana
  • Roser, J.
  • Senra, C.
  • Viegas, R.
  • Llosá, Gabriela
The IRIS group at IFIC-Valencia has developed a second version of a Compton camera prototype for hadron therapy treatment monitoring, with the aim of improving the performance with respect to its predecessor. The system is composed of three Lanthanum (III) bromide (LaBr) crystals coupled to silicon photomultipliers (SiPMs). The detector energy resolution has been improved to 5.6% FWHM at 511 keV and an angular resolution of 8.0° has been obtained. Images of a Na point-like source have been reconstructed selecting two and three interaction events. Moreover, the experimental data have been reproduced with Monte Carlo simulations using a Compton camera module (CCMod) in GATE v8.2 obtaining a good correlation.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Image reconstruction for a multi-layer Compton telescope: an analytical model for three interaction events

  • Roser, Jorge
  • Muñoz, Enrique
  • Barrientos, Luis
  • Barrio, John
  • Bernabéu, José
  • Borja-Lloret, Marina
  • Etxebeste, Ane
  • Llosá, Gabriela
  • Ros García, Ana
  • Viegas, Rita
  • Oliver, Josep F.
Compton Cameras are electronically collimated photon imagers suitable for sub-MeV to few MeV gamma-ray detection. Such features are desirable to enable in vivo range verification in hadron therapy, through the detection of secondary Prompt Gammas. A major concern with this technique is the poor image quality obtained when the incoming gamma-ray energy is unknown. Compton Cameras with more than two detector planes (multi-layer Compton Cameras) have been proposed as a solution, given that these devices incorporate more signal sequences of interactions to the conventional two interaction events. In particular, three interaction events convey more spectral information as they allow inferring directly the incident gamma-ray energy. A three-layer Compton Telescope based on continuous Lanthanum (III) Bromide crystals coupled to Silicon Photomultipliers is being developed at the IRIS group of IFIC-Valencia. In a previous work we proposed a spectral reconstruction algorithm for two interaction events based on an analytical model for the formation of the signal. To fully exploit the capabilities of our prototype, we present here an extension of the model for three interaction events. Analytical expressions of the sensitivity and the System Matrix are derived and validated against Monte Carlo simulations. Implemented in a List Mode Maximum Likelihood Expectation Maximization algorithm, the proposed model allows us to obtain four-dimensional (energy and position) images by using exclusively three interaction events. We are able to recover the correct spectrum and spatial distribution of gamma-ray sources when ideal data are employed. However, the uncertainties associated to experimental measurements result in a degradation when real data from complex structures are employed. Incorrect estimation of the incident gamma-ray interaction positions, and missing deposited energy associated with escaping secondaries, have been identified as the causes of such degradation by means of a detailed Monte Carlo study. As expected, our current experimental resolution and efficiency to three interaction events prevents us from correctly recovering complex structures of radioactive sources. However, given the better spectral information conveyed by three interaction events, we expect an improvement of the image quality of conventional Compton imaging when including such events. In this regard, future development includes the incorporation of the model assessed in this work to the two interaction events model in order to allow using simultaneously two and three interaction events in the image reconstruction., This work has received funding from the Spanish Ministerio de Ciencia, Innovación y Universidades (FPA2017-85611-R and IFIC's Center of Excellence Severo Ochoa SEV-2014-0398), from CSIC PIC 2018 programme under the reference N 2018FR0032 and from European Commission H2020 ENSAR2-MediNet (project No. 654002). Group members are supported by Ramón y Cajal, Severo Ochoa Excellence postdoctoral contract, UVEG Atracció de Talent and Generalitat Valenciana contracts., With funding from the Spanish goverment through the "Severo Ochoa Centre of Excellence" accreditation (SEV-2014-0398), Peer reviewed