Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanostructured Ti-Zr-Pd-Si-(Nb) bulk metallic composites, novel biocompatible materials with superior mechanical strength and elastic recovery

  • Hynowska, Anna
  • Blanquer, Andreu|||0000-0002-3551-1885
  • Pellicer, Eva|||0000-0002-8901-0998
  • Fornell Beringues, Jordina|||0000-0002-0909-3843
  • Suriñach, Santiago|||0000-0001-8125-0594
  • Baró, M. D.|||0000-0002-8636-1063
  • Gebert, A.
  • Calin, Mariana
  • Eckert, Jürgen|||0000-0003-4112-3181
  • Nogués, Carme|||0000-0002-6361-8559
  • Ibáñez, Elena|||0000-0002-0275-6958
  • Barrios, Leonardo|||0000-0002-6151-8503
  • Sort, Jordi|||0000-0003-1213-3639
The microstructure, mechanical behaviour, and biocompatibility (cell culture, morphology, and cell adhesion) of nanostructured Ti45 Zr15 Pd35- x Si5 Nbx with x = 0, 5 (at. %) alloys, synthesized by arc melting and subsequent Cu mould suction casting, in the form of rods with 3 mm in diameter, are investigated. Both Ti-Zr-Pd-Si-(Nb) materials show a multi-phase (composite-like) microstructure. The main phase is cubic β-Ti phase (Im3m) but hexagonal α-Ti (P63/mmc), cubic TiPd (Pm3m), cubic PdZr (Fm3m), and hexagonal (Ti, Zr)5 Si3 (P63/mmc) phases are also present. Nanoindentation experiments show that the Ti45 Zr15 Pd30 Si5 Nb5 sample exhibits lower Young's modulus than Ti45 Zr15 Pd35 Si5 . Conversely, Ti45 Zr15 Pd35 Si5 is mechanically harder. Actually, both alloys exhibit larger values of hardness when compared with commercial Ti-40Nb, (HTi-Zr-Pd-Si ≈ 14 GPa, HTi-Zr-Pd-Si-Nb ≈ 10 GPa and HTi-40Nb ≈ 2.7 GPa). Concerning the biological behaviour, preliminary results of cell viability performed on several Ti-Zr-Pd-Si-(Nb) discs indicate that the number of live cells is superior to 94% in both cases. The studied Ti-Zr-Pd-Si-(Nb) bulk metallic system is thus interesting for biomedical applications because of the outstanding mechanical properties (relatively low Young's modulus combined with large hardness), together with the excellent biocompatibility.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Designing new biocompatible glass-forming Ti₇₅ˍₓ Zr₁₀ Nbₓ Si₁₅ (x = 0, 15) alloys, corrosion, passivity, and apatite formation

  • Abdi, Somayeh
  • Oswald, Steffen
  • Gostin, Petre Flaviu
  • Helth, Arne
  • Sort, Jordi|||0000-0003-1213-3639
  • Baró, M. D.|||0000-0002-8636-1063
  • Calin, Mariana
  • Schultz, Ludwig
  • Eckert, Jürgen|||0000-0003-4112-3181
  • Gebert, Annett|||0000-0003-2748-3850
Glass-forming Ti-based alloys are considered as potential new materials for implant applications. Ti75-xZr10NbxSi15 alloys (free cytotoxic elements) can be produced as melt-spun ribbons with glassy matrix and embedded single β-type macrocrystals. The corrosion and passivation behavior of these alloys in their homogenized melt-spun states have been investigated in Ringer solution at 37º C in comparison to their cast multiphase crystalline counterparts and to cp-Ti and β-type Ti-40Nb. All tested materials showed very low corrosion rates as expressed in corrosion current densities i corr <50nA/cm2. Electrochemical and surface analytical studies revealed a high stability of the new alloys passive states in a wide potential range. This corresponds to low passive current densities. . .
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Improvement to the Corrosion Resistance of Ti-Based Implants Using Hydrothermally Synthesized Nanostructured Anatase Coatings

  • Lorenzetti, Martina
  • Pellicer, Eva|||0000-0002-8901-0998
  • Sort, Jordi|||0000-0003-1213-3639
  • Baró, M. D.|||0000-0002-8636-1063
  • Kovač, Janez
  • Novak, Saša
  • Kobe, Spomenka
The electrochemical behavior of polycrystalline TiO2 anatase coatings prepared by a one-step hydrothermal synthesis on commercially pure (CP) Ti grade 2 and a Ti13Nb13Zr alloy for bone implants was investigated in Hank's solution at 37.5 °C. The aim was to verify to what extent the in-situ-grown anatase improved the behavior of the substrate in comparison to the bare substrates. Tafel-plot extrapolations from the potentiodynamic curves revealed a substantial improvement in the corrosion potentials for the anatase coatings. Moreover, the coatings grown on titanium also exhibited lower corrosion-current densities, indicating a longer survival of the implant. The results were explained by considering the effects of crystal morphology, coating thickness and porosity. Evidence for the existing porosity was obtained from corrosion and nano-indentation tests. The overall results indicated that the hydrothermally prepared anatase coatings, with the appropriate morphology and surface properties, have attractive prospects for use in medical devices, since better corrosion protection of the implant can be expected.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Novel Ti-Zr-Hf-Fe Nanostructured Alloy for Biomedical Applications

  • Hynowska, Anna
  • Blanquer, Andreu|||0000-0002-3551-1885
  • Pellicer, Eva|||0000-0002-8901-0998
  • Fornell Beringues, Jordina|||0000-0002-0909-3843
  • Suriñach, Santiago|||0000-0001-8125-0594
  • Baró, M. D.|||0000-0002-8636-1063
  • González, Sergio
  • Ibáñez, Elena|||0000-0002-0275-6958
  • Barrios, Leonardo|||0000-0002-6151-8503
  • Nogués, Carme|||0000-0002-6361-8559
  • Sort, Jordi|||0000-0003-1213-3639
The synthesis and characterization of Ti40Zr20Hf20Fe20 (atom %) alloy, in the form of rods ( = 2 mm), prepared by arc-melting, and subsequent Cu mold suction casting, is presented. The microstructure, mechanical and corrosion properties, as well as in vitro biocompatibility of this alloy, are investigated. This material consists of a mixture of several nanocrystalline phases. It exhibits excellent mechanical behavior, dominated by high strength and relatively low Young's modulus, and also good corrosion resistance, as evidenced by the passive behavior in a wide potential window and the low corrosion current densities values. In terms of biocompatibility, this alloy is not cytotoxic and preosteoblast cells can easily adhere onto its surface and differentiate into osteoblasts.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Effect of surface modifications of Ti40Zr10Cu38Pd12 bulk metallic glass and Ti-6Al-4V alloy on human osteoblasts in vitro biocompatibility

  • Blanquer, Andreu|||0000-0002-3551-1885
  • Hynowska, Anna
  • Nogués, Carme|||0000-0002-6361-8559
  • Ibáñez, Elena|||0000-0002-0275-6958
  • Sort, Jordi|||0000-0003-1213-3639
  • Baró, M. D.|||0000-0002-8636-1063
  • Özkale, Berna|||0000-0002-3016-9363
  • Pané i Vidal, Salvador|||0000-0003-0147-8287
  • Pellicer, Eva|||0000-0002-8901-0998
  • Barrios, Leonardo|||0000-0002-6151-8503
The use of biocompatible materials, including bulk metallic glasses (BMGs), for tissue regeneration and transplantation is increasing. The good mechanical and corrosion properties of Ti40Zr10Cu38Pd12 BMG and its previously described biocompatibility makes it a potential candidate for medical applications. However, it is known that surface properties like topography might play an important role in regulating cell adhesion, proliferation and differentiation. Thus, in the present study, Ti40Zr10Cu38Pd12 BMG and Ti6-Al-4V alloy were surface-modified electrochemically (nanomesh) or physically (microscratched) to investigate the effect of material topography on human osteoblasts cells (Saos-2) adhesion, proliferation and differentiation. For comparative purposes, the effect of mirror-like polished surfaces was also studied. Electrochemical treatments led to a highly interconnected hierarchical porous structure rich in oxides, which have been described to improve corrosion resistance, whereas microscratched surfaces showed a groove pattern with parallel trenches. Cell viability was higher than 96% for the three topographies tested and for both alloy compositions. In all cases, cells were able to adhere, proliferate and differentiate on the alloys, hence indicating that surface topography plays a minor role on these processes, although a clear cell orientation was observed on microscratched surfaces. Overall, our results provide further evidence that Ti40Zr10Cu38Pd12 BMG is an excellent candidate, in the present two topographies, for bone repair purposes.