Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 19
Encontrada(s) 1 página(s)

IRTA Pubpro. Open Digital Archive
Publication Artículo científico (JournalArticle)

A Metal-Free and Biotically Degradable Battery for Portable Single-Use Applications

  • Esquivel, Juan Pablo
  • Alday, Perla
  • Ibrahim, Omar A.
  • Fernández, Belén
  • Kjeang, Erik
  • Sabaté, Neus
This article presents a new approach for environmentally benign, low-cost batteries intended for single-use applications. The proposed battery is designed and fabricated using exclusively organic materials such as cellulose, carbon, and wax and features an integrated quinone-based redox chemistry to generate electricity within a compact form factor. This primary capillary flow battery is activated by the addition of a liquid sample and has shown continuous operation up to 100 min with an output voltage that can be conveniently scaled to match the voltage needs of portable electronic devices (1.5–3.0 V). Once depleted, the battery can be disposed of without the need for any recycling facility, as its components are nontoxic and shown to be biotically degradable in a standardized test. The practical utility of the battery is demonstrated by direct substitution of a lithium ion coin cell in a diagnostic application., info:eu-repo/semantics/publishedVersion
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Paper-based enzymatic microfluidic fuel cell: From a two-stream flow device to a single-stream lateral flow strip

  • González-Guerrero, Maria Jose
  • Campo García, Francisco Javier del
  • Esquivel Bojórquez, Juan Pablo
  • Giroud, Fabien
  • Minteer, Shelley
  • Sabaté Vizcarra, Neus
This work presents a first approach towards the development of a cost-effective enzymatic paper-based glucose/O2 microfluidic fuel cell in which fluid transport is based on capillary action. A first fuel cell configuration consists of a Y-shaped paper device with the fuel and the oxidant flowing in parallel over carbon paper electrodes modified with bioelectrocatalytic enzymes. The anode consists of a ferrocenium-based polyethyleneimine polymer linked to glucose oxidase (GOx/Fc-C6-LPEI), while the cathode contains a mixture of laccase, anthracene-modified multiwall carbon nanotubes, and tetrabutylammonium bromide-modified Nafion (MWCNTs/laccase/TBAB-Nafion). Subsequently, the Y-shaped configuration is improved to use a single solution containing both, the anolyte and the catholyte. Thus, the electrolytes pHs of the fuel and the oxidant solutions are adapted to an intermediate pH of 5.5. Finally, the fuel cell is run with this single solution obtaining a maximum open circuit of 0.55 ± 0.04 V and a maximum current and power density of 225 ± 17 μA cm−2 and 24 ± 5 μW cm−2, respectively. Hence, a power source closer to a commercial application (similar to conventional lateral flow test strips) is developed and successfully operated. This system can be used to supply the energy required to power microelectronics demanding low power consumption., F. Javier del Campo acknowledges funding from the Spanish Ministry of Economy through the DADDi2 project (TEC2013-48506-C3). Juan Pablo Esquivel would like to thank the support from Marie Curie International Outgoing Fellowship (APPOCS-328144) within the 7th European Community Framework Programme. Shelley D. Minteer and Fabien Giroud would like to thank the National Science Foundation (CHE-1057597) for funding. Neus Sabaté acknowledges funding from the European H2020 Framework Programme (Grant Agreement 648518 - SUPERCELL - ERC 2014 CoG)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Paper-based microfluidic biofuel cell operating under glucose concentrations within physiological range

  • González-Guerrero, Maria Jose
  • Campo García, Francisco Javier del
  • Esquivel Bojórquez, Juan Pablo
  • Leech, Donal
  • Sabaté Vizcarra, Neus
This work addresses the development of a compact paper-based enzymatic microfluidic glucose/O2 fuel cell that can operate using a very limited sample volume (≈35 µl) and explores the energy generated by glucose at concentrations typically found in blood samples at physiological conditions (pH 7.4). Carbon paper electrodes combined with a paper sample absorption substrate all contained within a plastic microfluidic casing are used to construct the paper-based fuel cell. The anode catalysts consist of glucose dehydrogenase and [Os(4,4′-dimethoxy-2,2′-bipyridine)2(poly-vinylimidazole)10Cl]+ as mediator, while the cathode catalysts were bilirubin oxidase and [Os(2,2′-bipyridine)2(poly-vinylimidazole)10Cl]+ as mediator. The fuel cell delivered a linear power output response to glucose over the range of 2.5–30 mM, with power densities ranging from 20 to 90 µW cm−2. The quantification of the available electrical power as well as the energy density extracted from small synthetic samples allows planning potential uses of this energy to power different sensors and analysis devices in a wide variety of in-vitro applications., Peter Ó Conghaile is thanked for synthesis of the redox polymers. Neus Sabaté acknowledges funding from the European H2020 Framework Programme (Grant Agreement 648518 - SUPERCELL - ERC 2014 CoG). Juan Pablo Esquivel would like to thank the support from Marie Curie International Outgoing Fellowship (APPOCS) within the 7th European Community Framework Programme. F. Javier del Campo acknowledges funding from the Spanish Ministry of Economy through the DADDi2 project (TEC2013-48506-C3). Dónal Leech acknowledges support from Grant number 607793 under the Bioenergy FP7-PEOPLE-2013-ITN Programme., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Single-use paper-based hydrogen fuel cells for point-of-care diagnostic applications

  • Esquivel Bojórquez, Juan Pablo
  • Buser, R.S.
  • Lim, C.W.
  • Domínguez Fernández, Carlota
  • Rojas, Sergio
  • Yager, Paul
  • Sabaté Vizcarra, Neus
This work demonstrates a stand-alone power source that integrates a paper-based hydrogen fuel cell with a customized chemical heater that produces hydrogen in-situ upon the addition of a liquid. The presented approach operates by capillary action and takes advantage of the hydrogen released as a by-product of an exothermic reaction used in point-of-care diagnostics. The paper-based fuel cell produces a maximum power of 25.8 mW (103.2 mW cm−2), which is suitable for powering a diversity of electrical devices such as commercially available digital pregnancy tests and glucometers. While device shape and dimensions can be customized, here it is shown that the fuel cell can be designed in a compact form factor and footprint comparable to a lateral flow test while providing a remarkable power output. This approach holds great promise for powering portable diagnostics, as the generated electric power could enable device functionalities required for advanced assays, such as device timing, actuation, and signal quantification. Part of the same liquid sample that is to be analyzed (urine, saliva, water, etc) could be used to trigger the hydrogen generation and start the fuel cell operation., J.P. Esquivel acknowledges support from Marie Curie International Outgoing Fellowship (APPOCS - GA.328144) within the 7th European Community Framework Programme. J. Buser and P. Yager were supported by a grant from DARPA DSO/BTO--HR0011-11-2-0007, awarded to Yager at the University of Washington. P. Yager was supported in part by funds from the Department of Bioengineering at the University of Washington. S. Rojas acknowledges financial support from project ENE2013-42322R. N. Sabaté would like to thank financial support received from ERC Consolidator Grant (SUPERCELL - GA.648518)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Self-powered smart patch for sweat conductivity monitoring

  • Ortega, L.
  • Llorella, A.
  • Esquivel Bojórquez, Juan Pablo
  • Sabaté Vizcarra, Neus
A self-powered skin patch for the measurement of sweat conductivity is presented. The key component of the patch consists of a paper battery that is activated upon absorption of sweat. This body fluid acts as the battery electrolyte, the conductivity of which has a direct impact on the battery-generated output power and voltage. This particular behaviour enables the operation of a very simple and robust conductivity sensor in direct current mode without needing an external power source. The device presented in this paper takes advantage of this new measurement method to develop a sweat patch for screening cystic fibrosis that operates with an extremely simple electronic circuit that minimizes its cost and environmental impact. The patch provides an unambiguous digital result that can be read in an electrochromic display and yields 95% sensitivity and 100% specificity when tested with artificial eccrine perspiration samples.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

‘Plug-and-Power’ Point-of-Care diagnostics: A novel approach for self-powered electronic reader-based portable analytical devices

  • Montes-Cebrián, Y.
  • del Torno-de Román, L.
  • Álvarez-Carulla, A.
  • Colomer-Farrarons, J.
  • Minteer, S.D.
  • Sabaté Vizcarra, Neus
  • Miribel-Català, P.L.
  • Esquivel Bojórquez, Juan Pablo
This paper presents an innovative approach in the portable Point-of-Care diagnostics field, the Plug-and-Power concept. In this new disposable sensor and plug-and-play reader paradigm, the energy required to perform a measurement is always available within the disposable test component. The reader unit contains all the required electronic modules to run the test, process data and display the result, but does not include any battery or power source. Instead, the disposable part acts as both the sensor and the power source. Additionally, this approach provides environmental benefits related to battery usage and disposal, as the paper-based power source has non-toxic redox chemistry that makes it eco-friendly and safe to follow the same waste stream as disposable test strips. The feasibility of this Plug-and-Power approach is demonstrated in this work with the development of a self-powered portable glucometer consisting of two parts: a test strip including a paper-based power source and a paper-based biofuel cell as a glucose sensor; and an application-specific battery-less electronic reader designed to extract the energy from the test strip, process the signal provided and show the glucose concentration on a display. The device was tested with human serum samples with glucose concentrations between 5 and 30 mM, providing quantitative results in good agreement with commercial measuring instruments. The advantages of the present approach can be extended to any kind of biosensors measuring different analytes and biological matrices, and in this way, strengthen the goals of Point-of-Care diagnostics towards laboratory decentralization, personalized medicine and improving patient compliance., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Biopolymer Electrolyte Membranes (BioPEMs) for Sustainable Primary Redox Batteries

  • Alday, P. P.
  • Barros, Sandra Cerqueira
  • Alves, R.
  • Esperança, J. M. S. S.
  • Navarro-Segarra, M.
  • Sabaté Vizcarra, Neus
  • Silva, M. M.
  • Esquivel Bojórquez, Juan Pablo
The proliferation of portable electronic devices has resulted in an increase of e-waste that is generated after their use. One of the most hazardous components in e-waste are batteries, due to their content of heavy metals and toxic chemicals. Fuel cells and redox flow batteries have been recognized as more sustainable alternatives to Li-based batteries for powering portable applications. Although they provide comparable energy and power densities, they still face some challenges because they rely on proton exchange membranes based on nonenvironmentally friendly, high-priced perfluorosulfonic acid copolymers that require energy-intense manufacturing and recycling procedures. In this work, eco-friendly and sustainable biopolymer electrolyte membranes (BioPEMs) are synthesized from biopolymers like chitosan, cellulose, and starch. These BioPEMs bring forth advantages in performance, sustainability, and cost. Additionally, they present good chemical and mechanical stability, high ionic conductivity in the same order of magnitude as Nafion membranes. Two alternatives of cellulose–chitosan based BioPEMs are successfully applied into primary redox batteries using benign eco-friendly redox chemistries, delivering open circuit voltages above 0.75 V and power output up to 2.5 mW cm. These results demonstrate BioPEMs capability to improve biodegradable batteries in sectors requiring a transient electrical energy, such as environmental monitoring, agriculture, or packaging., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Electro-fluidic timer for event control in paper-based devices

  • Llorella, A.
  • Navarro-Segarra, M.
  • Merino-Jimenez, Irene
  • Esquivel Bojórquez, Juan Pablo
  • Sabaté Vizcarra, Neus
In this paper, we present a simple yet smart electro-fluidic platform that enables automatic time control in a very affordable and simple manner. The system is based on the electric detection of a fluid front when it crosses a particular area of a paper strip. The detection can be used to trigger the sequential activation or deactivation of different electronic modules (heating of molecular diagnostics, time interval detection, or readout of test results) with an accuracy within the range of minutes. The whole system is implemented with a few number of discrete electronic components such as transistors, resistors and capacitors that, if required, can be totally fabricated using printed electronics technology. This platform opens new possible applications for paper-based point-of care (POC) diagnostic devices and enables the possibility of these devices to introduce time control functions without the need for any external instrumentation and human action.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

An Organic Redox Flow Cell‐Inspired Paper‐Based Primary Battery

  • Navarro‐Segarra, Marina
  • Alday, Perla Patricia
  • García, David
  • Ibrahim, Omar A.
  • Kjeang, Erik
  • Sabaté Vizcarra, Neus
  • Esquivel Bojórquez, Juan Pablo
A portable paper‐based organic redox flow primary battery using sustainable quinone chemistry is presented. The compact prototype relies on the capillary forces of the paper matrix to develop a quasi‐steady flow of the reactants through a pair of porous carbon electrodes without the need of external pumps. Co‐laminar capillary flow allows operation Under mixed‐media conditions, in which an alkaline anolyte and an acidic catholyte are employed. This feature enables higher electrochemical cell voltages during discharge operation and the utilization of a wider range of available species and electrolytes and provides the advantage to form a neutral or near‐neutral pH as the electrolytes neutralize at the absorbent pad, which allows a safe disposal after use. The effects of the device design parameters have been studied to enhance battery features such as power output, operational time, and fuel utilization. The device achieves a faradaic efficiency of up to 98 %, which is the highest reported in a capillary‐based electrochemical power source, as well as a cell capacity of up to 11.4 Ah L−1 cm−2, comparable to state‐of‐the‐art large‐scale redox flow cells., The funding for this research provided through the Science for Solving Society's Problems Challenge by the Electrochemical Society and the Bill & Melinda Gates Foundation is highly appreciated. P.A. acknowledges support from CONACyT through a scholarship to pursue postgraduate studies. N.S. is thankful for financial support received from ERC Consolidator Grant (SUPERCELL—GA.648518). Additional support from the Natural Sciences and Engineering Research Council of Canada (NSERC), Canada Foundation for Innovation (CFI) and British Columbia Knowledge Development Fund (BCKDF) is also acknowledged. E.K. acknowledges support from the Canada Research Chairs program., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Standalone operation of an EGOFET for ultra-sensitive detection of HIV

  • KumarSailapu, Sunil
  • Macchia, Eleonora
  • Merino-Jimenez, Irene
  • Esquivel Bojórquez, Juan Pablo
  • Sarcina, Lucia
  • Scamarcio, G.
  • Minteer, Shelley D.
  • Torsi, Luisa
  • Sabaté Vizcarra, Neus
A point-of-care (POC) device to enable de-centralized diagnostics can effectively reduce the time to treatment, especially in case of infectious diseases. However, many of the POC solutions presented so far do not comply with the ASSURED (affordable, sensitive, specific, user-friendly, rapid and robust, equipment free, and deliverable to users) guidelines that are needed to ensure their on-field deployment. Herein, we present the proof of concept of a self-powered platform that operates using the analysed fluid, mimicking a blood sample, for early stage detection of HIV-1 infection. The platform contains a smart interfacing circuit to operate an ultra-sensitive electrolyte-gated field-effect transistor (EGOFET) as a sensor and facilitates an easy and affordable readout mechanism. The sensor transduces the bio-recognition event taking place at the gate electrode functionalized with the antibody against the HIV-1 p24 capsid protein, while it is powered via paper-based biofuel cell (BFC) that extracts the energy from the analysed sample itself. The self-powered platform is demonstrated to achieve detection of HIV-1 p24 antigens in fM range, suitable for early diagnosis. From these developments, a cost-effective digital POC device able to detect the transition from “healthy” to “infected” state at single-molecule precision, with no dependency on external power sources while using minimal components and simpler approach, is foreseen., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Paper-Based Batteries as Conductivity Sensors for Single-Use Applications

  • Ortega, L.
  • Llorella, A.
  • Esquivel Bojórquez, Juan Pablo
  • Sabaté Vizcarra, Neus
We present a novel approach to measure ionic conductivity with a self-powered strategy. In particular, we propose the use of a paper-based battery as a sensor. The battery sensor unit consists of two electrodes placed side-by-side and covered by a piece of hydrophilic paper strip. The electrodes are externally connected to a resistive element. The addition of the fluid to be sensed - which acts as the electrolyte - activates the battery, which generates an output voltage that is dependent on the conductivity of the liquid sample. The device, which is conceived as a single-use disposable sensor, has been tested with different synthetic and biological liquid samples. The battery sensor effectiveness has been assessed by comparing its performance with a commercial laboratory conductometer. The device opens new avenues for conductivity monitoring in small portable and wearable devices, as it simplifies the number of electronic components and the need of additional power sources.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Nanoceria dissolution at acidic pH by breaking off the catalytic loop

  • Galyamin, Dmitry
  • Ernst, Lena M.
  • Fitó-Parera, Aina
  • Mira-Vidal, Guillem
  • Bastús, Neus G.
  • Sabaté Vizcarra, Neus
  • Puntes, Víctor F.
This manuscript proves the reproducibility and robustness of cerium oxide nanoparticles, nanoceria, employed as a chemical reagent with oxidizing capacity (as an electron sink) at acidic pH. Unlike nanoceria multi-enzyme-mimetic capabilities at neutral or high pH, nanoceria can behave as a stoichiometric reagent at low pH where insoluble Ce4+ ions transform into soluble Ce3+ in the nanocrystal that finally dissolves. This behaviour can be interpreted as enzyme-like when nanoceria is in excess with respect to the substrate. Under these conditions, the Ce3+/Ce4+ ratio in the NPs can easily be estimated by titration with ferrocyanide. This procedure could become a rapid assessment tool for evaluating nanoceria capacity in liquid environments., N. Sabaté would like to acknowledge the financial support received from ERC Consolidator Grant (SUPERCELL – GA.648518). N. G. B and V. P. acknowledge financial support from the Spanish Ministerio de Ciencia, Innovación y Universidades (MCIU) (RTI2018-099965-B-I00, AEI/FEDER,UE) proyectos de I + D + i de programación conjunta internacional MCIN/AEI (CONCORD, PCI2019-103436) cofunded by the European Union and Generalitat de Catalunya (2017-SGR-1431). ICN2 is supported by the Severo Ochoa program from Spanish MINECO (SEV-2017-0706) and is funded by the CERCA Programme/Generalitat de Catalunya. Dmitry Galyamin thanks the doctoral program “Electroquímica. Ciència i Tecnologia” of the Universitat Autònoma de Barcelona (UAB)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Immuno-battery: A single use self-powered immunosensor for REASSURED diagnostics

  • Galyamin, Dmitry
  • Liébana, Susana
  • Esquivel Bojórquez, Juan Pablo
  • Sabaté Vizcarra, Neus
In this work, we present a novel self-powered approach totally independent from any external energy source. We have developed a self-powered paper-based immunosensor that generates energy in the presence of the biomarker in the sample. In particular, the device - which has been labeled as Immuno-Battery - makes use of magnesium as anode and the widely employed HRP-labeled antibody as cathodic catalyst to detect C-reactive protein (CRP) presence in artificial samples. Feasibility of self-powered sensing is proved by submitting the immuno-battery to a resistive load. In this regime, the sensor provides operation voltages above 1.55 V and maximum power densities from 40 to 571 μW cm-2 that allow for future implementation of an electronic readout circuit. We have demonstrated that sensitivity of the system is not compromised by the self-powered mode operation, as the LOD value delivered by our battery (20 ± 2 ng mL-1) is compliant with LOD values reported for protein detection in paper-based electrochemical immunoassays with chronoamperometric methods. Moreover, as a case study, a LOD of 269 ± 39 ng mL-1 is obtained for CRP detection, in accordance with available commercial high-sensitivity CRP detection kits. This proof-of-concept opens the path towards the development of digital diagnostic devices in a sustainable and affordable manner., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Towards a REASSURED reality: A less-is-more electronic design strategy for self-powered glucose test

  • Sailapu, Sunil Kumar
  • Liébana, Susana
  • Merino-Jimenez, Irene
  • Esquivel Bojórquez, Juan Pablo
  • Sabaté, Neus
Sensing strategies adopting minimal electronic systems help in realizing REASSURED diagnostic tests. However, the challenge in developing such strategies escalates with demand in power and electronics during pursuit of reliable and accurate sensing. Herein, we present an electronic design strategy using a smart strip, operating with power generated from 3.5 μL of serum sample, to reveal glucose concentration through a response preserved in a capacitor. Further, by integrating an NFC tag alongside the strip, we devised a self-powered glucose measuring card, mobile-glucocard (or mGlucocard) for retrieving this stored digital response using smartphone, enabling 'connected mobile-health diagnostics'. The response from our device relates linearly to glucose concentration offering a sensitivity of 11.3 mV/mM and good correlation (R = 0.974) with colorimetric reference method. Interestingly, the design strategy uses only four components - two resistors, diode, and capacitor - of simple architecture likely transferable to printed technologies to deliver advanced self-powered sustainable devices., Funding text 1 The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: The authors declare no competing interests: Neus Sabate reports financial support was provided by European Research Council.The work was supported by the ERC Consolidator Grant (SUPERCELL \u2013 GA.648518). The authors thank Alliance Niyigena for help in conducting experiments; also, Claudia Delgado, Urbez Santana and David Otero from Eurecat for interesting discussions around digitization of the signal. Funding text 2 The work was supported by the ERC Consolidator Grant ( SUPERCELL \u2013 GA.648518 ). The authors thank Alliance Niyigena for help in conducting experiments; also, Claudia Delgado, Urbez Santana and David Otero from Eurecat for interesting discussions around digitization of the signal., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Research data Set de datos (Dataset)

Towards a REASSURED reality: A less-is-more electronic design strategy for self-powered glucose test

  • Sailapu, Sunil Kumar
  • Liébana, Susana
  • Merino-Jimenez, Irene
  • Esquivel Bojórquez, Juan Pablo
  • Sabaté, Neus
Sensing strategies adopting minimal electronic systems help in realizing REASSURED diagnostic tests. However, the challenge in developing such strategies escalates with demand in power and electronics during pursuit of reliable and accurate sensing. Herein, we present an electronic design strategy using a smart strip, operating with power generated from 3.5 μL of serum sample, to reveal glucose concentration through a response preserved in a capacitor. Further, by integrating an NFC tag alongside the strip, we devised a self-powered glucose measuring card, mobile-glucocard (or mGlucocard) for retrieving this stored digital response using smartphone, enabling 'connected mobile-health diagnostics'. The response from our device relates linearly to glucose concentration offering a sensitivity of 11.3 mV/mM and good correlation (R = 0.974) with colorimetric reference method. Interestingly, the design strategy uses only four components - two resistors, diode, and capacitor - of simple architecture likely transferable to printed technologies to deliver advanced self-powered sustainable devices., Funding text 1 The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: The authors declare no competing interests: Neus Sabate reports financial support was provided by European Research Council.The work was supported by the ERC Consolidator Grant (SUPERCELL \u2013 GA.648518). The authors thank Alliance Niyigena for help in conducting experiments; also, Claudia Delgado, Urbez Santana and David Otero from Eurecat for interesting discussions around digitization of the signal. Funding text 2 The work was supported by the ERC Consolidator Grant ( SUPERCELL \u2013 GA.648518 ). The authors thank Alliance Niyigena for help in conducting experiments; also, Claudia Delgado, Urbez Santana and David Otero from Eurecat for interesting discussions around digitization of the signal., No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Unveiling the effect of paper matrix on the electrochemical response of diffusive redox probes

  • Galyamin, Dmitry
  • Laborda, Eduardo
  • Esquivel Bojórquez, Juan Pablo
  • González, Joaquín
  • Sabaté, Neus
This study evaluates the influence of paper substrate selection on the electrochemical response of an electrochemical paper-based analytical device (ePAD). Various paper substrates commonly employed in this type of devices such as cellulose, nitrocellulose and glass-fibre based medical grade materials are evaluated using chronoamperometric measurements. Both theoretical modelling and experimental analyses are conducted to understand the diffusion behaviour of widely employed two redox probes, [Fe(CN)<inf>6</inf>]<sup>3−</sup> and FcMeOH. Findings show that glass fibre substrates show similar performance to liquid drop conditions while nitrocellulose cause a decrease in current after a short measurement period, mainly due to a thin-layer effect. Cellulose-based substrates decrease the diffusivity of redox species, especially for charged species, indicating potential limitations in their use for chronoamperometric measurements. The study offers valuable insights into the electrochemical behaviour of paper substrates in ePADs, laying the groundwork for future research in this area., The authors thank D. Batet for his help in the SEM inspection of paper substrates. N. Sabat\u00E9 would like to thank the financial support received from the ERC ConsolidatorGrant (SUPERCELL-GA.648518) . E. L. and J. G. greatly appreciate the financial support provided by the Ministerio de Ciencia e Innovaci\u00F3n by MCIN/AEI/10.13039/501100011033 and the European Union \u201CNextGenerationEU\u201D/PRTR\" through the project TED2021\u2013130334B-I00 ., Peer reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A Metal-Free and Biotically Degradable Battery for Portable Single-Use Applications

  • Esquivel, Juan Pablo
  • Alday, Perla
  • Ibrahim, Omar A.
  • Fernández, Belén
  • Kjeang, Erik
  • Sabaté, Neus
This article presents a new approach for environmentally benign, low-cost batteries intended for single-use applications. The proposed battery is designed and fabricated using exclusively organic materials such as cellulose, carbon, and wax and features an integrated quinone-based redox chemistry to generate electricity within a compact form factor. This primary capillary flow battery is activated by the addition of a liquid sample and has shown continuous operation up to 100 min with an output voltage that can be conveniently scaled to match the voltage needs of portable electronic devices (1.5–3.0 V). Once depleted, the battery can be disposed of without the need for any recycling facility, as its components are nontoxic and shown to be biotically degradable in a standardized test. The practical utility of the battery is demonstrated by direct substitution of a lithium ion coin cell in a diagnostic application., info:eu-repo/semantics/publishedVersion
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

A plant-like battery, a biodegradable power source ecodesigned for precision agriculture

  • Navarro-Segarra, Marina
  • Tortosa, Carles
  • Ruiz-Díez, Carlos
  • Desmaële, Denis
  • Gea, Teresa|||0000-0003-2523-4797
  • Barrena, Raquel|||0000-0002-6077-7765
  • Sabaté Vizcarra, Neus|||0000-0002-4513-7057
  • Esquivel, Juan Pablo|||0000-0002-3181-3077
The natural environment has always been a source of inspiration for the research community. Nature has evolved over thousands of years to create the most complex living systems, with the ability to leverage inner and outside energetic interactions in the most efficient way. This work presents a flow battery profoundly inspired by nature, which mimics the fluid transport in plants to generate electric power. The battery was ecodesigned to meet a life cycle for precision agriculture (PA) applications; from raw material selection to disposability considerations, the battery is conceived to minimize its environmental impact while meeting PA power requirements. The paper-based fluidic system relies on evaporation as the main pumping force to pull the reactants through a pair of porous carbon electrodes where the electrochemical reaction takes place. This naturally occurring transpiration effect enables to significantly expand the operational lifespan of the battery, overcoming the time-limitation of current capillary-based power sources. Most relevant parameters affecting the battery performance, such as evaporation flow and redox species degradation, are thoroughly studied to carry out device optimization. Flow rates and power outputs comparable to those of capillary-based power sources are achieved. The prototype practicality has been demonstrated by powering a wireless plant-caring device. Standardized biodegradability and phytotoxicity assessments show that the battery is harmless to the environment at the end of its operational lifetime. Placing sustainability as the main driver leads to the generation of a disruptive battery concept that aims to address societal needs within the planetary environmental boundaries. A biodegradable battery inspired by the transpiration pull of liquids in plants has been ecodesigned to power wireless sensors and then be safely biodegraded or composted, resembling the way a plant comes back to nature at the end of its lifecycle.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Nanoceria dissolution at acidic pH by breaking off the catalytic loop

  • Galyamin, Dmitry|||0000-0002-4301-7027
  • Ernst, Lena M.|||0000-0002-5713-7513
  • Fitó-Parera, Aina
  • Mira-Vidal, Guillem|||0000-0002-3143-1562
  • Bastús, Neus G|||0000-0002-3144-7986
  • Sabaté Vizcarra, Neus|||0000-0002-4513-7057
  • Puntes, Víctor|||0000-0001-8996-9499
This manuscript proves the reproducibility and robustness of cerium oxide nanoparticles, nanoceria, employed as a chemical reagent with oxidizing capacity (as an electron sink) at acidic pH. Unlike nanoceria multi-enzyme-mimetic capabilities at neutral or high pH, nanoceria can behave as a stoichiometric reagent at low pH where insoluble Ce4+ ions transform into soluble Ce3+ in the nanocrystal that finally dissolves. This behaviour can be interpreted as enzyme-like when nanoceria is in excess with respect to the substrate. Under these conditions, the Ce3+/Ce4+ ratio in the NPs can easily be estimated by titration with ferrocyanide. This procedure could become a rapid assessment tool for evaluating nanoceria capacity in liquid environments.