Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Nonlinearity of optoacoustic signals and a new contrast mechanism for imaging

  • Malekzadeh Najafabadi, Jaber
  • Prakash, Jaya
  • Razansky, Daniel
  • Ripoll Lorenzo, Jorge
  • Gujrati, Vipul
  • Ntziachristos, Vasilis
Optoacoustic signals behave nonlinearly at light fluences above a few mJ/cm2, which may affect the interpretation and quantification of measurements. It has been proposed that optoacoustic nonlinearity arises from the heat-induced formation of nanobubbles or changes in local thermo-physical parameters. However, such explanations are only valid at much higher fluences than typically used in biomedical optoacoustic imaging (> 20 mJ/cm2) or in the presence of materials with high absorption coefficients such as gold nanoparticles. We propose herein that electromagnetic permittivity changes in response to photon absorption are major source of optoacoustic signal nonlinearity at low fluences. We provide theoretical and experimental evidence that supports this postulation and show that optoacoustic pressure responses due to permittivity changes, which are function of thermally excited third-order nonlinear susceptibility, can explain the nonlinear behavior of the optoacoustic signal. Since different materials exhibit different thermally excited third-order nonlinear susceptibility, this property could function as a new contrast mechanism that can identify the sensitivity of a substance's dielectric constant to photon-induced temperature changes. Consequently, we propose an imaging method based on nonlinear optoacoustic signals that exploits this newly identified contrast mechanism. These findings may have far-reaching implications for improving the accuracy of optoacoustics and utilizing the proposed new contrast mechanism would advance our understanding of cellular and tissue functionality., This work was funded by the European Union under the 7th Framework Program grant agreement no 605162 (BERTI), the European Union's Horizon 2020 research and innovation programme under grant agreement no. 687866 (INNODERM) and no. 862811 (RSENSE), and the Deutsche Forschungsgemeinschaft (DFG) as part of the CRC 1123 (Z1). JR acknowledges funding from the European Commission grant agreement No 801347 (SENSITIVE), and Spanish Ministry of Economy and Competitiveness (MINECO) Grant FIS2016-77892-R. Jaya Prakash acknowledges the Alexander von Humboldt Postdoctoral Fellowship program. The authors appreciate the editing assistance of Robert Wilson, PhD and A. Chapin Rodríguez, PhD.
Biblos-e Archivo. Repositorio Institucional de la UAM
Publication Artículo científico (JournalArticle)

Quality control in clinical raster-scan optoacoustic mesoscopy

  • He, Hailong
  • Fischer, Chiara
  • Darsow, Ulf
  • Aguirre Bueno, Juan
  • Ntziachristos, Vasilis
Optoacoustic (photoacoustic) mesoscopy bridges the gap between optoacoustic microscopy and macroscopy and enables high-resolution visualization deeper than optical microscopy. Nevertheless, as images may be affected by motion and noise, it is critical to develop methodologies that offer standardization and quality control to ensure that high-quality datasets are reproducibly obtained from patient scans. Such development is particularly important for ensuring reliability in applying machine learning methods or for reliably measuring disease biomarkers. We propose herein a quality control scheme to assess the quality of data collected. A reference scan of a suture phantom is performed to characterize the system noise level before each raster-scan optoacoustic mesoscopy (RSOM) measurement. Using the recorded RSOM data, we develop a method that estimates the amount of motion in the raw data. These motion metrics are employed to classify the quality of raw data collected and derive a quality assessment index (QASIN) for each raw measurement. Using simulations, we propose a selection criterion of images with sufficient QASIN, leading to the compilation of RSOM datasets with consistent quality. Using 160 RSOM measurements from healthy volunteers, we show that RSOM images that were selected using QASIN were of higher quality and fidelity compared to non-selected images. We discuss how this quality control scheme can enable the standardization of RSOM images for clinical and biomedical applications, This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 871763 (WINTHER) and under grant agreement No 687866 (INNODERM). Dr. He would like to thank the Helmholtz Imaging Platform (HIP: Deep4OM). Dr. Aguirre would like to thank support from the Madrid Autonomous Region Talento Project 2020-T1/TIC-20661