Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 19
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Automatic Segmentation of Epidermis and Hair Follicles in Optical Coherence Tomography Images of Normal Skin by Convolutional Neural Networks

  • del Amor, Rocío
  • Morales, Sandra|||0000-0003-0763-1545
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • Mogensen, Mette
  • Jensen, Mikkel
  • Israelsen, Niels M.
  • Bang, Ole
[EN] Optical coherence tomography (OCT) is a well-established bedside imaging modality that allows analysis of skin structures in a non-invasive way. Automated OCT analysis of skin layers is of great relevance to study dermatological diseases. In this paper, an approach to detect the epidermal layer along with the follicular structures in healthy human OCT images is presented. To the best of the authors' knowledge, the approach presented in this paper is the only epidermis detection algorithm that segments the pilosebaceous unit, which is of importance in the progression of several skin disorders such as folliculitis, acne, lupus erythematosus, and basal cell carcinoma. The proposed approach is composed of two main stages. The first stage is a Convolutional Neural Network based on U-Net architecture. The second stage is a robust post-processing composed by a Savitzky-Golay filter and Fourier Domain Filtering to fully define the borders belonging to the hair follicles. After validation, an average Dice of 0.83 +/- 0.06 and a thickness error of 10.25 mu mis obtained on 270 human skin OCT images. Based on these results, the proposed method outperforms other state-of-the-art methods for epidermis segmentation. It demonstrates that the proposed image segmentation method successfully detects the epidermal region in a fully automatic way in addition to defining the follicular skin structures as main novelty., This work has been partially supported by Horizon 2020, the European Union's Framework Programme for Research and Innovation, under grant agreement No. 732613 (GALAHAD Project), the Spanish Ministry of Economy and Competitiveness through project DPI2016-77869, and GVA through project PROMETEO/2019/109. The OCT system and the work of NI were funded by Innovation Fund Denmark, Grant No. 4107-00011A (ShapeOCT).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Circumpapillary OCT-Focused Hybrid Learning for Glaucoma Grading Using Tailored Prototypical Neural Networks

  • García-Pardo, José Gabriel
  • Verdú-Monedero, Rafael
  • Morales-Sanchez, Juan
  • del Amor, Rocío
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Glaucoma is one of the leading causes of blindness worldwide and Optical Coherence Tomography (OCT) is the quintessential imaging technique for its detection. Unlike most of the state-of-the-art studies focused on glaucoma detection, in this paper, we propose, for the first time, a novel framework for glaucoma grading using raw circumpapillary B-scans. In particular, we set out a new OCT-based hybrid network which combines hand-driven and deep learning algorithms. An OCT-specific descriptor is proposed to extract hand-crafted features related to the retinal nerve fibre layer (RNFL). In parallel, an innovative CNN is developed using skip-connections to include tailored residual and attention modules to refine the automatic features of the latent space. The proposed architecture is used as a backbone to conduct a novel few-shot learning based on static and dynamic prototypical networks. The k-shot paradigm is redefined giving rise to a supervised end-to-end system which provides substantial improvements discriminating between healthy, early and advanced glaucoma samples. The training and evaluation processes of the dynamic prototypical network are addressed from two fused databases acquired via Heidelberg Spectralis system. Validation and testing results reach a categorical accuracy of 0.9459 and 0.8788 for glaucoma grading, respectively. Besides, the high performance reported by the proposed model for glaucoma detection deserves a special mention. The findings from the class activation maps are directly in line with the clinicians' opinion since the heatmaps pointed out the RNFL as the most relevant structure for glaucoma diagnosis., This work has been partially funded by the following projects: [H2020-ICT-2016-2017, 732613] , DPI2016-77869-C2-1-R, PROM-ETEO/2019/109, AES2017-PI17/00771, AES2017-PI17/00821 and 20901/PI/18. The work of Gabriel Garcia has been supported by the Spanish State Research Agency PTA2017-14610-I
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Glaucoma Detection from Raw SD-OCT Volumes: a Novel Approach Focused on Spatial Dependencies

  • García-Pardo, José Gabriel
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Background and objective:Glaucoma is the leading cause of blindness worldwide. Many studies based on fundus image and optical coherence tomography (OCT) imaging have been developed in the literature to help ophthalmologists through artificial-intelligence techniques. Currently, 3D spectral-domain optical coherence tomography (SD-OCT) samples have become more important since they could enclose promising information for glaucoma detection. To analyse the hidden knowledge of the 3D scans for glaucoma detection, we have proposed, for the first time, a deep-learning methodology based on leveraging the spatial dependencies of the features extracted from the B-scans. Methods:The experiments were performed on a database composed of 176 healthy and 144 glaucomatous SD-OCT volumes centred on the optic nerve head (ONH). The proposed methodology consists of two well-differentiated training stages: a slide-level feature extractor and a volume-based predictive model. The slide-level discriminator is characterised by two new, residual and attention, convolutional modules which are combined via skip-connections with other fine-tuned architectures. Regarding the second stage, we first carried out a data-volume conditioning before extracting the features from the slides of the SD-OCT volumes. Then, Long Short-Term Memory (LSTM) networks were used to combine the recurrent dependencies embedded in the latent space to provide a holistic feature vector, which was generated by the proposed sequential-weighting module (SWM). Results:The feature extractor reports AUC values higher than 0.93 both in the primary and external test sets. Otherwise, the proposed end-to-end system based on a combination of CNN and LSTM networks achieves an AUC of 0.8847 in the prediction stage, which outperforms other state-of-the-art approaches intended for glaucoma detection. Additionally, Class Activation Maps (CAMs) were computed to highlight the most interesting regions per B-scan when discerning between healthy and glaucomatous eyes from raw SD-OCT volumes. Conclusions:The proposed model is able to extract the features from the B-scans of the volumes and combine the information of the latent space to perform a volume-level glaucoma prediction. Our model, which combines residual and attention blocks with a sequential weighting module to refine the LSTM outputs, surpass the results achieved from current state-of-the-art methods focused on 3D deep-learning architectures., The authors gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan V GPU used here., This work has been funded by GALAHAD project [H2020-ICT-2016-2017, 732613], SICAP project (DPI2016-77869-C2-1-R) and GVA through project PROMETEO/2019/109. The work of Gabriel García has been supported by the State Research Spanish Agency PTA2017-14610-I.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Resin-embedded murine ex vivo retina as durable models for optical coherence tomography

  • Barroso, Álvaro
  • Ketelhut, Steffi
  • Heiduschka, Peter
  • Kemper, Björn
  • Schnekenburger, Jürgen
  • del Amor, Rocío
  • García-Torres, Fernando|||0000-0002-5337-8774
  • Morales, Sandra|||0000-0003-0763-1545
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] High-resolution optical coherence tomography (HR-OCT) systems require standardized, biologically relevant phantoms to enable reproducible performance evaluation and benchmarking. In this study, we present an optimized method for preparing durable 3D retina phantoms from resin-embedded ex vivo mouse eyes. Mechanical polishing and cutting techniques were applied to improve sample geometry, enabling better positioning of retinal tissue relative to the resin¿air interface. The modified samples were characterized by using a commercial HR-OCT system operating at 905¿nm. Quantitative analysis of B-scan images revealed enhanced signal contrast, particularly in the upper retinal layers, due to reduced scattering. This approach improves the anatomical fidelity and imaging performance of retina phantoms, offering a promising tool for calibration and comparative assessment of advanced HR-OCT systems., Funding by the European Union through the programs Horizon 2020 (Project GALAHAD, no.: 732613) and Horizon Europe (Project SEQUOIA; no.:101070062) are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Deep Learning-based Approach for the Semantic Segmentation of Bright Retinal Damage

  • Silva, Cristiana
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
Regular screening for the development of diabetic retinopathy is imperative for an early diagnosis and a timely treatment, thus preventing further progression of the disease. The conventional screening techniques based on manual observation by qualified physicians can be very time consuming and prone to error. In this paper, a novel automated screening model based on deep learning for the semantic segmentation of exudates in color fundus images is proposed with the implementation of an end-to-end convolutional neural network built upon UNet architecture. This encoder-decoder network is characterized by the combination of a contracting path and a symmetrical expansive path to obtain precise localization with the use of context information. The proposed method was validated on E-OPHTHA and DIARETDB1 public databases achieving promising results compared to current state-of-theart methods., This paper was supported by the European Union’s Horizon 2020 research and innovation programme under the Project GALAHAD [H2020-ICT2016-2017, 732613]. The work of Adri´an Colomer has been supported by the Spanish Government under a FPI Grant [BES-2014-067889]. We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan Xp GPU used for this research.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

CNNs for Automatic Glaucoma Assessment using Fundus Images: An Extensive Validation

  • Díaz-Pinto, Andrés Yesid
  • Köhler, Thomas
  • Navea, Amparo
  • Morales, Sandra|||0000-0003-0763-1545
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • Mossi García, José Manuel|||0000-0001-9083-3476
[EN] Background: Most current algorithms for automatic glaucoma assessment using fundus images rely on handcrafted features based on segmentation, which are affected by the performance of the chosen segmentation method and the extracted features. Among other characteristics, Convolutional Neural Networks (CNNs) are known because of their ability to learn highly discriminative features from raw pixel intensities. Methods: In this paper, we employed five different ImageNet-trained models (VGG16, VGG19, InceptionV3, ResNet50 and Xception) for automatic glaucoma assessment using fundus images. Results from an extensive validation using cross-validation and cross-testing strategies were compared with previous works in the literature. Results: Using five public databases (1707 images), an average AUC of 0.9605 with a 95% confidence interval of 95.92% - 97.07%, an average specificity of 0.8580 and an average sensitivity of 0.9346 were obtained after using the Xception architecture, significantly improving the performance of other state-of-the-art works. Moreover, a new clinical database, ACRIMA, has been made publicly available, containing 705 labelled images. It is composed of 396 glaucomatous images and 309 normal images, which means, the largest public database for glaucoma diagnosis. The high specificity and sensitivity obtained from the proposed approach are supported by an extensive validation using not only the cross-validation strategy but also the cross-testing validation on, to the best of the authors' knowledge, all publicly available glaucoma-labelled databases. Conclusions:These results suggest that using ImageNet-trained models is a robust alternative for automatic glaucoma screening system. All images, CNN weights and software used to fine-tune and test the five CNNs are publicly available, which could be used as a testbed for further comparisons., This work was supported by the Ministerio de Economia y Competitividad of Spain, Project ACRIMA [TIN2013-46751-R] and the Project GALAHAD [H2020-ICT-2016-2017, 732613]. In particular, the work of Andres Diaz-Pinto has been supported by the Generalitat Valenciana under the scholarship Santiago Grisolia [GRISOLIA/2015/027]. (Corresponding author: Andres Diaz-Pinto). We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan V GPU used for this research.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Towards Automatic Glaucoma Assessment: An Encoder-decoder CNN for Retinal Layer Segmentation in Rodent OCT images

  • del Amor, Rocío
  • Woldbye, David
  • Klemp, Kristian
  • Larsen, Michael
  • Morales, Sandra|||0000-0003-0763-1545
  • Colomer, Adrián|||0000-0002-7616-6029
  • Mossi García, José Manuel|||0000-0001-9083-3476
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Optical coherence tomography (OCT) is an important imaging modality that is used frequently to monitor the state of retinal layers both in humans and animals. Automated OCT analysis in rodents is an important method to study the possible toxic effect of treatments before the test in humans. In this paper, an automatic method to detect the most significant retinal layers in rat OCT images is presented. This algorithm is based on an encoder-decoder fully convolutional network (FCN) architecture combined with a robust method of post-processing. After the validation, it was demonstrated that the proposed method outperforms the commercial Insight image segmentation software. We obtained results (averaged absolute distance error) in the test set for the training database of 2.52±0.80 µm. In the predictions done by the method, in a different database (only used for testing), we also achieve the promising results of 4.45 ± 3.02 µm., This work was supported by the Project GALAHAD [H2020-ICT-2016-2017, 732613].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Computer-aided Glaucoma Diagnosis using Stochastic Watershed Transformation on Single Fundus Images

  • Díaz-Pinto, Andrés Yesid
  • Navea, Amparo
  • Morales, Sandra|||0000-0003-0763-1545
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Glaucoma is a chronic eye disease and one of the major causes of permanent blindness. Since it does not show initial symptoms, early diagnosis is important to limit its progression. This paper presents an automatic optic nerve characterization algorithm for glaucoma diagnosis based only on retinal fundus images. For optic cup segmentation, we used a new method based on the stochastic watershed transformation applied on the YIQ colour space to extract clinical indicators such as the Cup/Disc ratio, the area Cup/Disc ratio and the ISNT rule. Afterwards, an assessment between normal and glaucomatous fundus images is performed. The proposed algorithm was evaluated on 6 different (private and public) databases containing 723 images (377 normal and 346 glaucomatous images) which achieved a specificity and sensitivity of 0.674 and 0.675, respectively. Moreover, an F-score of 0.770 was obtained when evaluating this method on the publicly available database Drishti-GS1. A comparison of the proposed work with other state-of-the-art methods demonstrates the robustness of the proposed algorithm; because it was tested using images from different databases with high variability, which is a common issue in this area. Additional comparisons with existing works for cup segmentation, that use the publicly available database Drishti-GS1, are also presented in this paper., The authors would like to thank K. Narasimhan from SASTRA University for facilitating access to their database and gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan V GPU used for this research. This work was supported by the Project GALAHAD [H2020-ICT-2016-2017, 732613]. In particular, the work of Andres Diaz-Pinto has been supported by the Generalitat Valenciana under the scholarship Santiago Grisolia [GRISOLIA/2015/027].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

A Self-Training Framework for Glaucoma Grading In OCT B-Scans

  • García-Pardo, José Gabriel
  • Verdú-Monedero, Rafael
  • Dolz, Jose
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] In this paper, we present a self-training-based framework for glaucoma grading using OCT B-scans under the presence of domain shift. Particularly, the proposed two-step learning methodology resorts to pseudo-labels generated during the first step to augment the training dataset on the target domain, which is then used to train the final target model. This allows transferring knowledge-domain from the unlabeled data. Additionally, we propose a novel glaucoma-specific backbone which introduces residual and attention modules via skip-connections to refine the embedding features of the latent space. By doing this, our model is capable of improving state-of-the-art from a quantitative and interpretability perspective. The reported results demonstrate that the proposed learning strategy can boost the performance of the model on the target dataset without incurring in additional annotation steps, by using only labels from the source examples. Our model consistently outperforms the baseline by 1¿3% across different metrics and bridges the gap with respect to training the model on the labeled target data., We gratefully acknowledge the support of the Generalitat Valenciana (GVA) for the donation of the DGX A100 used for this work, action co-financed by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER) de la Comunitat Valenciana 2014-2020 (IDIFEDER/2020/030).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Durable 3D murine ex vivo retina glaucoma models for optical coherence tomography

  • Barroso, Álvaro
  • Ketelhut, Steffi
  • Nettels-Hackert, Gerburg
  • Heiduschka, Peter
  • Naranjo, Valery
  • Kemper, Björn
  • Schnekenburger, Jürgen
  • del Amor, Rocío
[EN] Durable and standardized phantoms with optical properties similar to native healthy and disease-like biological tissues are essential tools for the development, performance testing, calibration and comparison of label-free high-resolution optical coherence tomography (HR-OCT) systems. Available phantoms are based on artificial materials and reflect thus only partially ocular properties. To address this limitation, we have performed investigations on the establishment of durable tissue phantoms from ex vivo mouse retina for enhanced reproduction of in vivo structure and complexity. In a proof-of-concept study, we explored the establishment of durable 3D models from dissected mouse eyes that reproduce the properties of normal retina structures and tissue with glaucoma-like layer thickness alterations. We explored different sectioning and preparation procedures for embedding normal and N-methyl-D-aspartate (NMDA)-treated mouse retina in transparent gel matrices and epoxy resins, to generate durable three-dimensional tissue models. Sample quality and reproducibility were quantified by thickness determination of the generated layered structures utilizing computer-assisted segmentation of OCT B-scans that were acquired with a commercial HR-OCT system at a central wavelength of 905 nm and analyzed with custom build software. Our results show that the generated 3D models feature thin biological layers close to current OCT resolution limits and glaucoma-like tissue alterations that are suitable for reliable HR-OCT performance characterization. The comparison of data from resin-embedded tissue with native murine retina in gels demonstrates that by utilization of appropriate preparation protocols, highly stable samples with layered structures equivalent to native tissues can be fabricated. The experimental data demonstrate our concept as a promising approach toward the fabrication of durable biological 3D models suitable for high-resolution OCT system performance characterization supporting the development of optimized instruments for ophthalmology applications., Horizon 2020 Project GALAHAD (732613); Horizon Europe Project SEQUOIA (101070062); Open Access Publication Fund of the University of Münster
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Retinal Image Synthesis for Glaucoma Assessment using DCGAN and VAE Models

  • Díaz-Pinto, Andrés Yesid
  • Xu, Yanwu
  • Frangi, Alejandro F.
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • Morales, Sandra|||0000-0003-0763-1545
The performance of a Glaucoma assessment system is highly affected by the number of labelled images used during the training stage. However, labelled images are often scarce or costly to obtain. In this paper, we address the problem of synthesising retinal fundus images by training a Variational Autoencoder and an adversarial model on 2357 retinal images. The innovation of this approach is in synthesising retinal images without using previous vessel segmentation from a separate method, which makes this system completely independent. The obtained models are image synthesizers capable of generating any amount of cropped retinal images from a simple normal distribution. Furthermore, more images were used for training than any other work in the literature. Synthetic images were qualitatively evaluated by 10 clinical experts and their consistency were estimated by measuring the proportion of pixels corresponding to the anatomical structures around the optic disc. Moreover, we calculated the mean-squared error between the average 2D-histogram of synthetic and real images, obtaining a small difference of 3e-4. Further analysis of the latent space and cup size of the images was performed by measuring the Cup/Disc ratio of synthetic images using a state-of-the-art method. The results obtained from this analysis and the qualitative and quantitative evaluation demonstrate that the synthesised images are anatomically consistent and the system is a promising step towards a model capable of generating labelled images., We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan Xp GPU used for this research. This work was supported by the Project GALAHAD [H2020-ICT-2016-2017, 732613]
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Deep-Learning-based Classification of Rat OCT images After Intravitreal Injection of ET-1 for Glaucoma Understanding

  • Fuentes-Hurtado, Félix José
  • Fedulov, Vadim
  • Woldbye, David
  • Klemp, Kristian
  • Torm, Marie
  • Larsen, Michael
  • Morales, Sandra|||0000-0003-0763-1545
  • Mossi García, José Manuel|||0000-0001-9083-3476
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
Optical coherence tomography (OCT) is a useful technique to monitor retinal damage. We present an automatic method to accurately classify rodent OCT images in healthy and pathological (before and after 14 days of intravitreal injection of Endothelin-1, respectively) making use of the DenseNet-201 architecture fine-tuned and a customized top-model. We validated the performance of the method on 1912 OCT images yielding promising results ( AUC=0.99±0.01 in a P=15 leave-P-out cross-validation). Besides, we also compared the results of the fine-tuned network with those achieved training the network from scratch, obtaining some interesting insights. The presented method poses a step forward in understanding pathological rodent OCT retinal images, as at the moment there is no known discriminating characteristic which allows classifying this type of images accurately. The result of this work is a very accurate and robust automatic method to distinguish between healthy and a rodent model of glaucoma, which is the backbone of future works dealing with human OCT images., Animal experiment permission was granted by the Danish Animal Experimentation Council (license number: 2017-15-0201-01213). We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan Xp GPU used for this research. This work was supported by the Project GALAHAD [H2020-ICT-2016-2017, 732613]
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Resin-embedded ex vivo mouse retina as durable phantoms for optical coherence tomography

  • Barroso, Álvaro
  • Ketelhut, Steffi
  • Heiduschka, Peter
  • Kemper, Björn
  • Schnekenburger, Jürgen
  • del Amor, Rocío
  • García-Torres, Fernando|||0000-0002-5337-8774
  • Morales, Sandra|||0000-0003-0763-1545
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Reliable performance testing, calibration, and comparative benchmarking of high-resolution optical coherence tomography (HR-OCT) systems requires durable and standardized phantoms with optical tissue properties. Here, we tested different sample preparation procedures combining various fixative mixtures, infiltration protocols and embedding resins for the establishment of durable retina phantoms. Sample quality was analyzed by evaluation of retina cell layers and tissue defects in volume scans acquired with a commercial HR-OCT system. Our results demonstrate that, by following appropriate preparation protocols, highly stable three-dimensional samples with layered structures as native healthy tissue can be fabricated. Even thin anatomic structures such as the ganglion single cell layer are preserved, which makes the new durable tissue phantoms highly suitable for reliable HR-OCT performance characterization., Funding by the European Union through the programs Horizon 2020 (Project GALAHAD, no.: 732613) and Horizon Europe (Project SEQUOIA; no.:101070062) are gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Retinal layer segmentation in rodent OCT images: Local intensity profiles &amp, fully convolutional neural networks

  • Morales, Sandra|||0000-0003-0763-1545
  • Colomer, Adrián|||0000-0002-7616-6029
  • Mossi García, José Manuel|||0000-0001-9083-3476
  • del Amor, Rocío
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • Woldbye, David
  • Klemp, Kristian
  • Larsen, Michael
[EN] Background and Objective: Optical coherence tomography (OCT) is a useful technique to monitor retinal layer state both in humans and animal models. Automated OCT analysis in rats is of great relevance to study possible toxic effect of drugs and other treatments before human trials. In this paper, two different approaches to detect the most significant retinal layers in a rat OCT image are presented. Methods: One approach is based on a combination of local horizontal intensity profiles along with a new proposed variant of watershed transformation and the other is built upon an encoder-decoder convolutional network architecture. Results: After a wide validation, an averaged absolute distance error of 3.77 +/- 2.59 and 1.90 +/- 0.91 mu m is achieved by both approaches, respectively, on a batch of the rat OCT database. After a second test of the deep-learning-based method using an unseen batch of the database, an averaged absolute distance error of 2.67 +/- 1.25 mu m is obtained. The rat OCT database used in this paper is made publicly available to facilitate further comparisons. Conclusions: Based on the obtained results, it was demonstrated the competitiveness of the first approach since outperforms the commercial Insight image segmentation software (Phoenix Research Labs) as well as its utility to generate labelled images for validation purposes speeding significantly up the ground truth generation process. Regarding the second approach, the deep-learning-based method improves the results achieved by the more conventional method and also by other state-of-the-art techniques. In addition, it was verified that the results of the proposed network can be generalized to new rat OCT images., Animal experiment permission was granted by the Danish Animal Experimentation Council (license number: 2017-15-020101213). We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan V GPU used for this research. This work has received funding from Horizon 2020, the European Union's Framework Programme for Research and Innovation, under grant agreement No. 732613 (GALAHAD Project), the Spanish Ministry of Economy and Competitiveness through project DPI2016-77869 and GVA through project PROMETEO/2019/109.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Comparison of Local Analysis Strategies for Exudate Detection in Fundus Images

  • Pereira, Joana
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
Diabetic Retinopathy (DR) is a severe and widely spread eye disease. Exudates are one of the most prevalent signs during the early stage of DR and an early detection of these lesions is vital to prevent the patient’s blindness. Hence, detection of exudates is an important diagnostic task of DR, in which computer assistance may play a major role. In this paper, a system based on local feature extraction and Support Vector Machine (SVM) classification is used to develop and compare different strategies for automated detection of exudates. The main novelty of this work is allowing the detection of exudates using non-regular regions to perform the local feature extraction. To accomplish this objective, different methods for generating superpixels are applied to the fundus images of E-OPHTA database and texture and morphological features are extracted for each of the resulting regions. An exhaustive comparison among the proposed methods is also carried out., This paper was supported by the European Union’s Horizon 2020 research and innovation programme under the Project GALAHAD [H2020-ICT2016-2017, 732613]. The work of Adri´an Colomer has been supported by the Spanish Government under a FPI Grant [BES-2014-067889]. We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan Xp GPU used for this research.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Automatic Segmentation of the Retinal Nerve Fiber Layer by Means of Mathematical Morphology and Deformable Models in 2D Optical Coherence Tomography Imaging

  • Berenguer-Vidal, Rafael
  • Verdú-Monedero, Rafael
  • Morales-Sánchez, Juan
  • Sellés-Navarro, Inmaculada
  • García-Pardo, José Gabriel
  • del Amor, Rocío
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Glaucoma is a neurodegenerative disease process that leads to progressive damage of the optic nerve to produce visual impairment and blindness. Spectral-domain OCT technology enables peripapillary circular scans of the retina and the measurement of the thickness of the retinal nerve fiber layer (RNFL) for the assessment of the disease status or progression in glaucoma patients. This paper describes a new approach to segment and measure the retinal nerve fiber layer in peripapillary OCT images. The proposed method consists of two stages. In the first one, morphological operators robustly detect the coarse location of the layer boundaries, despite the speckle noise and diverse artifacts in the OCT image. In the second stage, deformable models are initialized with the results of the previous stage to perform a fine segmentation of the boundaries, providing an accurate measurement of the entire RNFL. The results of the RNFL segmentation were qualitatively assessed by ophthalmologists, and the measurements of the thickness of the RNFL were quantitatively compared with those provided by the OCT inbuilt software as well as the state-of-the-art methods., This work was partially funded by Spanish National projects AES2017-PI17/00771 and AES2017-PI17/00821 (Instituto de Salud Carlos III), PID2019-105142RB-C21 (AI4SKIN) (Spanish Ministry of Economy and Competitiveness), PTA2017-14610-I (State Research Spanish Agency), regional project 20901/PI/18 (Fundacion Seneca) and Polytechnic University of Valencia (PAID-01-20).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Retinal Image Synthesis and Semi-supervised Learning for Glaucoma Assessment

  • Díaz-Pinto, Andrés Yesid
  • Xu, Yanwu
  • Frangi, Alejandro F.
  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • Morales, Sandra|||0000-0003-0763-1545
[EN] Recent works show that Generative Adversarial Networks (GANs) can be successfully applied to image synthesis and semi-supervised learning, where, given a small labelled database and a large unlabelled database, the goal is to train a powerful classifier. In this paper, we trained a retinal image synthesizer and a semi-supervised learning method for automatic glaucoma assessment using an adversarial model on a small glaucoma-labelled and large unlabelled database. Various studies have shown that glaucoma can be monitored by analyzing the optic disc and its surroundings, for that reason the images used in this work were automatically cropped around the optic disc. The novelty of this work is to propose a new retinal image synthesizer and a semi-supervised learning method for glaucoma assessment based on the Deep Convolutional Generative Adversarial Networks (DCGAN). In addition, and to the best of the authors' knowledge, this system is trained on an unprecedented number of publicly available images (86926 images). This system, hence, is not only able to generate images synthetically but to provide labels automatically. Synthetic images were qualitatively evaluated using t-SNE plots of features associated with the images and their anatomical consistency were estimated by measuring the proportion of pixels corresponding to the anatomical structures around the optic disc. The resulting image synthesizer is able to generate realistic (cropped) retinal images and, subsequently, the glaucoma classifier is able to classify them into glaucomatous and normal with high accuracy (AUC=0.9017). The obtained retinal image synthesizer and the glaucoma classifier could be used then to generate an unlimited number of cropped retinal images with glaucoma labels., This work was supported by the Project GALAHAD [H2020-ICT-2016-2017, 732613]. In particular, thework of Andres Diaz-Pinto has been supported by the Generalitat Valenciana under the scholarship Santiago Grisolía [GRISOLIA/2015/027]. The work of Adrián Colomer has been supported by the Spanish Government under a FPI Grant [BES-2014-067889].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Evaluation of fractal dimension effectiveness for damage detection in retinal background

  • Colomer, Adrián|||0000-0002-7616-6029
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
  • Mossi García, José Manuel|||0000-0001-9083-3476
  • Janvier, Thomas
[EN] This work investigates the characterization of bright lesions in retinal fundus images using texture analysis techniques. Exudates and drusen are evidences of retinal damage in diabetic retinopathy (DR) and age-related macular degeneration (AMD) respectively. An automatic detection of pathological tissues could make possible an early detection of these diseases. In this work, fractal analysis is explored in order to discriminate between pathological and healthy retinal texture. After a deep preprocessing step, in which spatial and colour normalization are performed, the fractal dimension is extracted locally by computing the Hurst exponent (H) along different directions. The greyscale image is described by the increments of the fractional Brownian motion model and the H parameter is computed by linear regression in the frequency domain. The ability of fractal dimension to detect pathological tissues is demonstrated using a home-made system, based on fractal analysis and Support Vector Machine, able to achieve around a 70% and 83% of accuracy in E-OPHTHA and DIARETDB1 public databases respectively. In a second experiment, the fractal descriptor is combined with texture information, extracted by the Local Binary Patterns, improving the bright lesion detection. Accuracy, sensitivity and specificity values higher than 89%, 80% and 90% respectively suggest that the method presented in this paper is a robust algorithm for describing retina texture and can be useful in the automatic detection of DR and AMD., This paper was supported by the European Union's Horizon 2020 research and innovation programme under the Project GALAHAD [H2020-ICT-2016-2017, 732613]. In addition, this work was partially funded by the Ministerio de Economia y Competitividad of Spain, Project SICAP [DPI2016-77869-C2-1-R]. The work of Adrian Colomer has been supported by the Spanish Government under a FPI Grant [BES-2014-067889]. We gratefully acknowledge the support of NVIDIA Corporation with the donation of the Titan Xp GPU used for this research.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Durable ex vivo mouse retina 3D tissue models for optical coherence tomography

  • Barroso, Álvaro
  • Heiduschka, Peter
  • Nettels-Hackert, Gerburg
  • Ketelhut, Steffi
  • Kemper, Björn
  • Schnekenburger, Jürgen
  • del Amor, Rocío
  • García-Torres, Fernando|||0000-0002-5337-8774
  • Morales, Sandra|||0000-0003-0763-1545
  • Naranjo Ornedo, Valeriana|||0000-0002-0181-3412
[EN] Durable phantoms with optical properties and layered structures like healthy and diseased tissues are highly desirable for reliable performance testing of novel high-resolution optical coherence tomography (HR-OCT) systems. In this context, we performed investigations on the establishment of durable 3D retina models from eyes dissected ex vivo from control mice and eyes from animals treated with N-methyl-D-aspartate (NMDA) which induces glaucoma-like tissue alterations. The comparison of data from resin-embedded tissue with native murine retina in gels demonstrates that by utilization of appropriate preparation protocols highly stable 3D samples with layered structures equivalent to native tissues can be fabricated which are suitable for reliable HR-OCT performance characterization., Funding by the European Union through the programs Horizon 2020 (Project GALAHAD, no.: 732613) and Horizon Europe (Project SEQUOIA; no.:101070062) are gratefully acknowledged.