Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 18
Encontrada(s) 1 página(s)

TECNALIA Publications
Publication Artículo científico (JournalArticle)

Making Bipedal Robot Experiments Reproducible and Comparable: The Eurobench Software Approach: The Eurobench Software Approach

  • Remazeilles, Anthony
  • Dominguez, Alfonso
  • Barralon, Pierre
  • Torres-Pardo, Adriana
  • Pinto, David
  • Aller, Felix
  • Mombaur, Katja
  • Conti, Roberto
  • Saccares, Lorenzo
  • Thorsteinsson, Freygardur
  • Prinsen, Erik
  • Cantón, Alberto
  • Castilla, Javier
  • Sanz-Morère, Clara B.
  • Tornero, Jesús
  • Torricelli, Diego
This study describes the software methodology designed for systematic benchmarking of bipedal systems through the computation of performance indicators from data collected during an experimentation stage. Under the umbrella of the European project Eurobench, we collected approximately 30 protocols with related testbeds and scoring algorithms, aiming at characterizing the performances of humanoids, exoskeletons, and/or prosthesis under different conditions. The main challenge addressed in this study concerns the standardization of the scoring process to permit a systematic benchmark of the experiments. The complexity of this process is mainly due to the lack of consistency in how to store and organize experimental data, how to define the input and output of benchmarking algorithms, and how to implement these algorithms. We propose a simple but efficient methodology for preparing scoring algorithms, to ensure reproducibility and replicability of results. This methodology mainly constrains the interface of the software and enables the engineer to develop his/her metric in his/her favorite language. Continuous integration and deployment tools are then used to verify the replicability of the software and to generate an executable instance independent of the language through dockerization. This article presents this methodology and points at all the metrics and documentation repositories designed with this policy in Eurobench. Applying this approach to other protocols and metrics would ease the reproduction, replication, and comparison of experiments.
RUC. Repositorio da Universidade da Coruña
Publication Contribución de congreso (ConferenceOutput)

Optimización del modelo de regresión lineal para la decodificación de las trayectorias cinemáticas del miembro inferior a partir de señales EEG, Optimisation of linear regression model for decoding lower limb kinematic trajectories from EEG signals

  • Ferre, Miguel Á.
  • Juan, Javier V.
  • Iáñez, Eduardo
  • Ortiz, Mario
  • Azorín, José M.
[Resumen] Los exoesqueletos activos se han convertido en una herramienta clave en la rehabilitación de pacientes con problemas de movilidad, especialmente, afectados con enfermedades relacionadas con el sistema nervioso durante la última década. Varios son los estudios que han demostrado que el movimiento consciente efectuado por pacientes con dificultades de movilidad, asistido por este tipo de dispositivos, contribuye positivamente a la recuperación de su movilidad, acortando los tiempos de rehabilitación y mejorando sus resultados. Además, otros estudios han planteado la teoría de que el córtex motor se encuentra activo durante fases específicas del ciclo de la marcha. En este estudio se ha hecho una búsqueda de nuevos parámetros para la mejora de un modelo de regresión multilineal que decodifica la cinemática de los miembros inferiores a partir de las señales de EEG. Además, se ha estudiado la generalización de estos nuevos parámetros para crear un modelo unificado que facilite su uso. Las nuevas configuraciones alcanzan valores medios (Coeficiente de correlación de Pearson) similares entre las trayectorias reales y las decodificadas 0,49 ± 0,20. Esto nos lleva a pensar que los nuevos parámetros se podrían generalizar sin ningún problema., [Abstract] During the last decade, active exoskeletons have become a key tool in the rehabilitation of patients with mobility problems, especially those affected by diseases related to the nervous system. Several studies have shown that conscious movement by patients with mobility difficulties, assisted by these devices, contributes positively to the recovery of their mobility, shortening rehabilitation times and improving outcomes. In addition, other studies have hypothesized that the motor cortex is active during specific phases of the gait cycle. In this study, new multi-linear regression model parameters have been analyzed for enhancing the decoding of lower limb kinematics from EEG signals. Besides, the generalization of these new parameters has been studied in order to create a unified model that facilitates its use. The new configurations achieve similar mean values (Pearson's correlation coefficient) between the real and decoded trajectories 0.49 ± 0.20. This leads to the conclusion that the new parameters could be generalized.
RUC. Repositorio da Universidade da Coruña
Publication Contribución de congreso (ConferenceOutput)

Desarrollo de BenchBalance: un sistema para la evaluación de la capacidad de equilibrio en exoesqueletos robóticos, BenchBalance: A System to Assess Benchmarking Balance Capabilities of Wearable Robots

  • Bayón, Cristina
  • Delgado-Oleas, Gabriel
  • Tagliamonte, Nevio L.
  • Asseldonk, Edwin van
  • Rocón, Eduardo
[Resumen] Avances recientes en el control de exoesqueletos se están centrando en mejorar la asistencia de equilibrio y disminuir la dependencia de las muletas. Sin embargo, métodos apropiados para cuantificar la estabilidad de estos exoesqueletos (y de sus usuarios) aún son escasos. Una evaluación del equilibrio cuantitativa es fundamental para enriquecer el desempeño de los exoesqueletos y su interacción con los seres humanos. En este trabajo presentamos el sistema BenchBalance, una soluci ón para realizar evaluaciones comparativas y reproducibles de equilibrio en exoesqueletos y sus usuarios. Al integrar dos elementos clave (perturbador manual y prenda inteligente), BenchBalance es una herramienta portátil y de bajo coste que proporciona una evaluación cuantitativa relacionada con la reacción y la capacidad de los exoesqueletos portátiles y sus usuarios para responder a perturbaciones externas controladas., [Abstract] Recent advances on the control of exoskeletons are being centered on improving balance support and decreasing the reliance on crutches. However, appropriate methods to quantify the stability of these exoskeletons (and and their users) are still under development. A reliable and reproducible balance assessment is critical to enrich exoskeletons’ performances and their interaction with human beings. In this work we present the BenchBalance system, a benchmarking solution to conduct reproducible balance assessments of exoskeleton and users. Integrating two key elements (manual perturbator and smart garment), BenchBalance is a portable and low-cost tool that provides a quantitative assessment related to the reaction and capacity of wearable exoskeletons and their users to respond to controlled external perturbations., Esta investigación ha sido financiada por el proyecto europeo EUROBENCH2020 (eurobench2020. eu), número de subvención n779963, https://doi.org/10.17979/spudc.9788497498043
RUC. Repositorio da Universidade da Coruña
Publication Contribución de congreso (ConferenceOutput)

Análisis de la configuración óptima de electrodos para la detección de atención en tarea de imaginación motora, Study of the Optimal Electrode Configuration for Attention Detection During a Motor Imagery Task

  • Ossa, Luis de la
  • Juan, Javier V.
  • Ortiz, Mario
  • Iáñez, Eduardo
  • Azorín, José M.
[Resumen] El uso de interfaces cerebro máquina (BCIs) supone un importante avance en el control de dispositivos para la rehabilitación de pacientes. Además, la detección de la atención durante la marcha puede ser fundamental a la hora de garantizar la seguridad en el control de estos dispositivos mediante electroencefalogramas (EEG) y evitar activaciones involuntarias. En esta investigación, realizamos un análisis de diferentes configuraciones de los electrodos que componen una BCI, tratando de discernir qué configuraciones detectan la atención de manera más precisa., [Abstract] The use of Brain-Machine Interfaces (BMIs) represents a relevant advance in the control of devices destinated to patients rehabilitation. Besides, attention detection during gait becomes vital when guaranteeing a safe control of this devices through electroencephalofraphic signals (EEG), in order to avoid involuntary activations. In this research, we analyze different BMI electrode configurations trying to assure which ones detetcs attention with the higher accuracy., Esta investigación ha sido realizada en el marco del proyecto DECODED, que ha recibido financiación del Programa de Investigación e Innovación Horizon 2020 de la Unión Europea, mediante una Open Call realizada y ejecutada bajo el proyecto EUROBENCH (grant agreement No 779963), https://doi.org/10.17979/spudc.9788497498043
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Compliant lower limb exoskeletons: a comprehensive review on mechanical design principles

  • Sanchez-Villamañan, Maria del Carmen
  • Gonzalez-Vargas, J.
  • Torricelli, Diego
  • Moreno, Juan Camilo
  • Pons Rovira, José Luis
Exoskeleton technology has made significant advances during the last decade, resulting in a considerable variety of solutions for gait assistance and rehabilitation. The mechanical design of these devices is a crucial aspect that affects the efficiency and effectiveness of their interaction with the user. Recent developments have pointed towards compliant mechanisms and structures, due to their promising potential in terms of adaptability, safety, efficiency, and comfort. However, there still remain challenges to be solved before compliant lower limb exoskeletons can be deployed in real scenarios. In this review, we analysed 52 lower limb wearable exoskeletons, focusing on three main aspects of compliance: actuation, structure, and interface attachment components. We highlighted the drawbacks and advantages of the different solutions, and suggested a number of promising research lines. We also created and made available a set of data sheets that contain the technical characteristics of the reviewed devices, with the aim of providing researchers and end-users with an updated overview on the existing solutions., This work is supported by the project EUROBENCH (European ROBotic framework for bipedal locomotion bENCHmarking) funded by H2020 Topic ICT 27–2017: “System abilities, SME & benchmarking actions, safety certification” (reference: 779963). We acknowledge support of the publication fee by the CSIC Open Access Publication Support Initiative through its Unit of Information Resources for Research (URICI)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Reorganization of Muscle Coordination Underlying Motor Learning in Cycling Tasks

  • Torricelli, Diego
  • De Marchis, C.
  • d´Avella, A.
  • Tobaruela, D.N.
  • Barroso, Filipe O.
  • Pons Rovira, José Luis
The hypothesis of modular control, which stands on the existence of muscle synergies as building blocks of muscle coordination, has been investigated in a great variety of motor tasks and species. Yet, its role during learning processes is still largely unexplored. To what extent is such modular control flexible, in terms of spatial structure and temporal activation, to externally or internally induced adaptations, is a debated issue. To address this question, we designed a biofeedback experiment to induce changes in the timing of muscle activations during leg cycling movements. The protocol consisted in delaying the peak of activation of one target muscle and using its electromyography (EMG) envelope as visual biofeedback. For each of the 10 healthy participants, the protocol was repeated for three different target muscles: Tibialis Anterioris (TA), Gastrocnemius Medialis (GM), and Vastus Lateralis (VL). To explore the effects of the conditioning protocol, we analyzed changes in the activity of eight lower limb muscles by applying different models of modular motor control [i.e., fixed spatial components (FSC) and fixed temporal components (FTC)]. Our results confirm the hypothesis that visual EMG biofeedback is able to induce changes in muscle coordination. Subjects were able to shift the peak of activation of the target muscle, with a delay of (49 ± 27°) across subjects and conditions. This time shift generated a reorganization of all the other muscles in terms of timing and amplitude. By using different models of modular motor control, we demonstrated that neither spatially invariant nor temporally invariant muscle synergies alone were able to account for these changes in muscle coordination after learning, while temporally invariant muscle synergies with adjustments in timing could capture most of muscle activity adaptations observed after the conditioning protocol. These results suggest that short-term learning in rhythmic tasks is built upon synergistic temporal commands that are robust to changes in the task demands., This research has been supported by Spanish project ASSOCIATE “A comprehensive and wearable robotics based approach to the rehabilitation and assistance of people with stroke and SCI” (DPI2014-58431-C4-1-R), and the H2020 project EUROBENCH “European Robotic Framework for Bipedal Locomotion Benchmarking” (Grant Agreement No. 779963).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Development and Evaluation of BenchBalance: A System for Benchmarking Balance Capabilities of Wearable Robots and Their Users

  • Bayón, Cristina
  • Delgado-Oleas, Gabriel
  • Avellar, Leticia
  • Bentivoglio, Francesca
  • Di Tommaso, Francesco
  • Tagliamonte, Nevio L.
  • Rocón, Eduardo
  • Asseldonk, Edwin H. F. van
Recent advances in the control of overground exoskeletons are being centered on improving balance support and decreasing the reliance on crutches. However, appropriate methods to quantify the stability of these exoskeletons (and their users) are still under development. A reliable and reproducible balance assessment is critical to enrich exoskeletons’ performance and their interaction with humans. In this work, we present the BenchBalance system, which is a benchmarking solution to conduct reproducible balance assessments of exoskeletons and their users. Integrating two key elements, i.e., a hand-held perturbator and a smart garment, BenchBalance is a portable and low-cost system that provides a quantitative assessment related to the reaction and capacity of wearable exoskeletons and their users to respond to controlled external perturbations. A software interface is used to guide the experimenter throughout a predefined protocol of measurable perturbations, taking into account antero-posterior and mediolateral responses. In total, the protocol is composed of sixteen perturbation conditions, which vary in magnitude and location while still controlling their orientation. The data acquired by the interface are classified and saved for a subsequent analysis based on synthetic metrics. In this paper, we present a proof of principle of the BenchBalance system with a healthy user in two scenarios: subject not wearing and subject wearing the H2 lower-limb exoskeleton. After a brief training period, the experimenter was able to provide the manual perturbations of the protocol in a consistent and reproducible way. The balance metrics defined within the BenchBalance framework were able to detect differences in performance depending on the perturbation magnitude, location, and the presence or not of the exoskeleton. The BenchBalance system will be integrated at EUROBENCH facilities to benchmark the balance capabilities of wearable exoskeletons and their users., This research was funded by the European project EUROBENCH2020 (eurobench2020.eu), grant number n779963, BenchBalance. This work benefited from work/discussions in the COST Action Wearable Robots CA16116, and the project Discover2Walk under Grant PID2019-105110RB-C31 by the Spanish Ministry of Science and Innovation., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Feasibility and Application of the B.E.A.T. Testbed for Assessing the Effects of Lower Limb Exoskeletons on Human Balance

  • Mileti, Ilaria
  • Taborri, Juri
  • Rodríguez-Cianca, David
  • Torricelli, Diego
  • Rossi, Stefano
  • Patanè, Fabrizio
Assessing the performance of exoskeletons in assisting human balance is important for their design process. This study proposes a novel testbed, the B.E.A.T (Balance Evaluation Automated Testbed) to address this aim. We applied the B.E.A.T to evaluate how the presence of a lower limb exoskeleton influenced human balance. The B.E.A.T. consists of a robotic platform, standardized protocols, and performance indicators. Fifteen healthy subjects were enrolled and subjected to repeatable step-type ground perturbations in different directions using the multi-axis robotic platform. Each participant performed three trials, both with and without the exoskeleton (EXO and No-EXO conditions). Nine performance indicators, divided into kinematic and body stability indicators, were computed. The reliability of performance indicators was assessed by computing the Inter Class Correlation (ICC). The indicators showed good (0.60 ≤ ICC < 0.75) to excellent (ICC ≥ 0.75) reliability. The comparison between the EXO and No-EXO conditions revealed a significant increase in the joint range of motion and the center of pressure displacement while wearing the exoskeleton. The main differences between the EXO and No-EXO conditions were found in the range of motion of the knee joints, with an increment up to 17° in the sagittal plane., This research was funded by the Project EUROBENCH (grant agreement N° 779963, PI: Fabrizio Patanè)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Making Bipedal Robot Experiments Reproducible and Comparable: The Eurobench Software Approach

  • Remazeilles, A.
  • Dominguez, A.
  • Barralon, Pierre
  • Torres-Pardo, Adriana
  • Pinto, D.
  • Aller, F.
  • Mombaur, Katja
  • Conti, R.
  • Saccares, L
  • Thorsteinsson, F.
  • Prinsen, E.
  • Cantón, A:
  • Castilla, Javier
  • Sanz-Morère, C.B.
  • Tornero, Jesús D.
  • Torricelli, Diego
This study describes the software methodology designed for systematic benchmarking of bipedal systems through the computation of performance indicators from data collected during an experimentation stage. Under the umbrella of the European project Eurobench, we collected approximately 30 protocols with related testbeds and scoring algorithms, aiming at characterizing the performances of humanoids, exoskeletons, and/or prosthesis under different conditions. The main challenge addressed in this study concerns the standardization of the scoring process to permit a systematic benchmark of the experiments. The complexity of this process is mainly due to the lack of consistency in how to store and organize experimental data, how to define the input and output of benchmarking algorithms, and how to implement these algorithms. We propose a simple but efficient methodology for preparing scoring algorithms, to ensure reproducibility and replicability of results. This methodology mainly constrains the interface of the software and enables the engineer to develop his/her metric in his/her favorite language. Continuous integration and deployment tools are then used to verify the replicability of the software and to generate an executable instance independent of the language through dockerization. This article presents this methodology and points at all the metrics and documentation repositories designed with this policy in Eurobench. Applying this approach to other protocols and metrics would ease the reproduction, replication, and comparison of experiments., This study is supported by the European Union’s Horizon 2020 research and innovation program under Grant Agreement no 779963, project Eurobench.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Quantifying the Impact of a Lower Limb Exoskeleton on Whole-Body Manipulation Tasks. Methodological Approach and First Results

  • Benito Molpeceres, Yaiza
  • Asín-Prieto, Guillermo
  • García Orden, Juan Carlos
  • Torricelli, Diego
In recent years, back-support exoskeletons have been postulated as a competitive solution to reduce mechanical loading during lifting tasks, contributing to the prevention of low back pain. However, little research involving lower body exoskeletons has been done on this matter. The present study evaluates the impact of the H2 robotic exoskeleton on whole-body manipulation tasks, through a standardized experimental protocol and a set of objective metrics. Wearing the exoskeleton allowed the subject to perform the tasks successfully, occasionally showing magnified range of movement values at certain joints. In addition, its use reduced back mechanical loading of loaded-box lifts. However, the device also had a non-desirable impact on functional performance, increasing postural instability, slowing down tasks completion, and diminishing movement smoothness., The work presented in this paper was supported by the European Union’s Horizon 2020 research and innovation program under grant agreement No 779963—EUROBENCH. The authors would like to acknowledge the support of Technaid S.L. for unconditionally providing the exoskeleton for this research.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Test Method for Exoskeleton Locomotion on Irregular Terrains: Testbed Design and Construction

  • Torres-Pardo, Adriana
  • Pinto-Fernández, David
  • Belalcázar-Bolaños, E.
  • Pons Rovira, José Luis
  • Moreno, Juan Camilo
  • Torricelli, Diego
This work aims to define a benchmarking scenario for the evaluation of the performance of lower limb exoskeletons while walking on irregular terrains. We designed a modular testbed that can be easily configured to replicate a wide range of uneven terrains. The testbed, based on several design criteria such as modularity, reproducibility, robustness and low-cost, aims to be a concrete solution to researchers and developers to test their systems according to a standardized method. The long term goal is to provide means to demonstrate the ability of new exoskeletal systems to operate safely and reliably in realistic out-of-the-lab conditions., This work has been supported by the H2020 Project EUROBENCH (grant number 779963, https://eurobench2020.eu/).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Towards a Unified Terminology for Benchmarking Bipedal Systems

  • Remazeilles, A.
  • Domínguez, Alfonso
  • Barralon, Pierre
  • Torricelli, Diego
In the European project EUROBENCH, we are developing a framework for benchmarking the performances of bipedal systems: from humans to humanoids through wearable robots. Fair benchmarking requires defining and sharing clear and complete protocols so that bipedal systems can be studied and compared within similar and reproducible conditions. Even if the experimental methods and system comparisons are common scientific tasks, the description of the experimental protocols that are followed are rarely complete enough to allow it to be replicated. We list, in this article, the information required to properly define a protocol (e.g. experiment objectives, testbeds, type of collected and processed data, performance indicators used to score and compare experiments). Agreeing on a common terminology for benchmarking concepts will ease the evaluation of new technologies and promote communication between the different stakeholders involved in the development and use of bipedal systems., Supported by the H2020 EUROBENCH project, grant No. 779963.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A method to quantify the reduction of back and hip muscle fatigue of lift-support exoskeletons

  • Van Sluijs
  • Rodríguez-Cianca, David
  • Sanz-Morère, C.B.
  • Massardi, Stefano
  • Bartenbach, V.
  • Torricelli, Diego
Cumulative back muscle fatigue plays a role in the occurrence of low-back injuries in occupations that require repetitive lifting of heavy loads and working in forward leaning postures. Lift-support exoskeletons have the potential to reduce back and hip muscle activity, thereby delaying the onset of fatigue in these muscles. Therefore, exoskeletons are being considered a potentially important tool to further reduce workload-related injuries. However, today no standards have been established on how to benchmark the support level of lift-support exoskeletons. This work proposes an experimental protocol to quantify the support level of a lift-support exoskeletons on instant changes in muscle activity and fatigue development while maintaining a static forward leaning posture. It then applies the protocol to experimentally assess the effect of the support provided by a commercially available lift-support exoskeleton, the LiftSuit 2.0 (Auxivo AG, Schwerzenbach, Switzerland), on the user. In a sample of 14 participants, the amplitude of the muscle activity of the back muscles and hip muscles was significantly reduced. Wearing the exoskeleton significantly reduced the amount of fatigue developed during the task . Changes in muscle fatigue can be objectively recorded and correlated with relevant changes for exoskeleton users: the time a task can be performed and perceived low-back fatigue. Thus, including such measures of fatigue in standardized benchmarking procedures will help quantify the benefits of exoskeletons for occupational use., This project has received funding from the European Union’s Horizon 2020 research and innovation program under the framework of the EUROBENCH project (grant agreement no. 779963).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Benchmarking the Effects on Human–Exoskeleton Interaction of Trajectory, Admittance and EMG-Triggered Exoskeleton Movement Control

  • Rodrigues-Carvalho, C.
  • Fernández-García,M.
  • Pinto-Fernández, David
  • Sanz-Morere, C.
  • Barroso, Filipe O.
  • Borromeo, S.
  • Rodríguez-Sánchez, C.
  • Moreno, Juan Camilo
  • Del-Ama, Antonio J.
Nowadays, robotic technology for gait training is becoming a common tool in rehabilitation hospitals. However, its effectiveness is still controversial. Traditional control strategies do not adequately integrate human intention and interaction and little is known regarding the impact of exoskeleton control strategies on muscle coordination, physical effort, and user acceptance. In this article, we benchmarked three types of exoskeleton control strategies in a sample of seven healthy volunteers: trajectory assistance (TC), compliant assistance (AC), and compliant assistance with EMG-Onset stepping control (OC), which allows the user to decide when to take a step during the walking cycle. This exploratory study was conducted within the EUROBENCH project facility. Experimental procedures and data analysis were conducted following EUROBENCH’s protocols. Specifically, exoskeleton kinematics, muscle activation, heart and breathing rates, skin conductance, as well as user-perceived effort were analyzed. Our results show that the OC controller showed robust performance in detecting stepping intention even using a corrupt EMG acquisition channel. The AC and OC controllers resulted in similar kinematic alterations compared to the TC controller. Muscle synergies remained similar to the synergies found in the literature, although some changes in muscle contribution were found, as well as an overall increase in agonist-antagonist co-contraction. The OC condition led to the decreased mean duration of activation of synergies. These differences were not reflected in the overall physiological impact of walking or subjective perception. We conclude that, although the AC and OC walking conditions allowed the users to modulate their walking pattern, the application of these two controllers did not translate into significant changes in the overall physiological cost of walking nor the perceived experience of use. Nonetheless, results suggest that both AC and OC controllers are potentially interesting approaches that can be explored as gait rehabilitation tools. Furthermore, the INTENTION project is, to our knowledge, the first study to benchmark the effects on human–exoskeleton interaction of three different exoskeleton controllers, including a new EMG-based controller designed by us and never tested in previous studies, which has made it possible to provide valuable third-party feedback on the use of the EUROBENCH facility and testbed, enriching the apprenticeship of the project consortium and contributing to the scientific community., The work presented here was supported by European Union’s Horizon 2020 research and innovation program under grant agreement No 779963, project EUROBENCH (European Robotic Framework for Bipedal Locomotion Benchmarking) through the FSTP-2 project INTENTION (Improving Human–Robot Interaction through EMG-Onset Controller for Lower Limb Exoskeletons). Camila Rodrigues-Carvalho has also been partially funded by CSIC Interdisciplinary Thematic Platform (PTI+) NEURO-AGINGl+ (PTI-NEURO-AGING+). This work was also partially funded by the Spanish MCIN/AEI/ 10.13039/501100011033 and by “European Union NextGenerationEU/PRTR”, under Grant agreement IJC2020-044467-I., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

How can ISO 13482:2014 account for the ethical and social considerations of robotic exoskeletons?

  • Fosch-Villaronga, E.
  • Calleja, C.J.
  • Drukarch,H.
  • Torricelli, Diego
This paper analyzes and classifies regulatory gaps and inconsistencies in ISO 13482:2014 (‘Safety Requirements for Personal Care Robots'), specifically regarding robotic lower-limb exoskeletons, being personal care robots, for everyday activities. Following a systematic literature review, our findings support the conclusion that, even though ISO 13482:2014 has proven to be a substantial step towards regulating that type of wearable robot, it fails to address safety sufficiently and comprehensively. That failure results in a general overlook of critical legal, ethical, and social considerations when designing robots, with the consequence that seemingly safe systems might nonetheless harm end-users. Notwithstanding those limitations and impediments to the development of safe technologies, to date, there has been no thorough assessment of how the standard regulates the development of exoskeletons and whether it requires any improvement in light of ethical, legal, and societal considerations. To bridge this gap, we compile relevant areas for improvement concerning ISO 13482:2014 fueled by these considerations. We do so in an accessible manner and provide concrete recommendations to help decision-makers overcome the standard's drawbacks., This project has been partly funded by the Safe and Sound project, a project that has received funding from the European Union’s Horizon- ERC program, Grant Agreement No. 101076929. Views and opinions expressed are, however, those of the author(s) only and do not necessarily reflect those of the European Union or the European Research Council. Neither the European Union nor the granting authority can be held responsible for them. This project has also received funding from the European Union’s Horizon 2020 research and innovation programme, via an Open Call issued and executed under Project EUROBENCH (grant agreement No. 779963)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Re-defining wearable robots: a multidisciplinary approach towards a unified terminology

  • Massardi, Stefano
  • Briem, K.
  • Briem, K.
  • Veneman, J.F.
  • Torricelli, Diego
  • Moreno, Juan C.
Effective communication is especially important in the wearable robots (WRs) community, which encloses a great variety of devices across different application domains, e.g., healthcare, occupational, and consumer. In this paper we present a vocabulary of terms with the aim to create a common understanding of terms and concepts among the different fields of expertise relevant in the WRs community. Our goal is to develop shared documentation that could serve as a reference to facilitate the use of accepted definitions in the field. The presented vocabulary is the result of different focus group discussions among experts in the field. The resulting document was then validated by presenting it to the WR community through an online survey. The results of the survey highlight a strong agreement in terms of acceptance of the vocabulary, its usefulness, and applicability of the proposed definitions as well as an overall appreciation for its purpose and target. This work represents a pilot study providing unique material for the WR community, encouraging the use of shared agreed definitions. The reported version of the vocabulary has been made available as a live document in a github repository, for public commenting and further improvements., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work received financial support by TAILOR project funded by MCIN/AEI/100.13039/501100011033 and by “ERDF A way of making Europe” under grant agreement RTI2018-097290-B-C32 and the EUROBENCH project funded by the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779963., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

AI-enabled photonic smart garment for movement analysis

  • Avellar, Leticia M.
  • Stefano Filho, Carlos
  • Delgado-Oleas, Gabriel
  • Frizera Neto, Anselmo
  • Rocón, Eduardo
  • Leal-Junior, Arnaldo
Smart textiles are novel solutions for remote healthcare monitoring which involve non-invasive sensors-integrated clothing. Polymer optical fiber (POF) sensors have attractive features for smart textile technology, and combined with Artificial Intelligence (AI) algorithms increase the potential of intelligent decision-making. This paper presents the development of a fully portable photonic smart garment with 30 multiplexed POF sensors combined with AI algorithms to evaluate the system ability on the activity classification of multiple subjects. Six daily activities are evaluated: standing, sitting, squatting, up-and-down arms, walking and running. A k-nearest neighbors classifier is employed and results from 10 trials of all volunteers presented an accuracy of 94.00 (0.14)%. To achieve an optimal amount of sensors, the principal component analysis is used for one volunteer and results showed an accuracy of 98.14 (0.31)% using 10 sensors, 1.82% lower than using 30 sensors. Cadence and breathing rate were estimated and compared to the data from an inertial measurement unit located on the garment back and the highest error was 2.22%. Shoulder flexion/extension was also evaluated. The proposed approach presented feasibility for activity recognition and movement-related parameters extraction, leading to a system fully optimized, including the number of sensors and wireless communication, for Healthcare 4.0., This research is financed by FAPES (84336650 and 320/2020), CNPq (304049/2019-0), Petrobras (2017/00702-6) and BenchBalance European Union (EU) Project (EU-H2020-779963-FSTP1-BenchBalance). This work was partially supported in part by the Spanish Ministry of Science and Innovation through the Project Discover2Walk under Grant PID2019-105110RB-C31, and Structural Funds of the EU (RoboCity) under Grant S2018/NMT-4331., Peer reviewed
Archivo Digital UPM
Publication Tesis doctoral (DoctoralThesis)

Monitoring Human-Exoskeleton Interaction with Multimodal Interfaces and AI