Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Characterization and Evaluation of Human-Exoskeleton Interaction Dynamics: A Review

  • Massardi, Stefano
  • Rodríguez-Cianca, David
  • Pinto-Fernández, David
  • Moreno, Juan Camilo
  • Lancini, Matteo
  • Torricelli, Diego
Exoskeletons and exosuits have witnessed unprecedented growth in recent years, especially in the medical and industrial sectors. In order to be successfully integrated into the current society, these devices must comply with several commercialization rules and safety standards. Due to their intrinsic coupling with human limbs, one of the main challenges is to test and prove the quality of physical interaction with humans. However, the study of physical human–exoskeleton interactions (pHEI) has been poorly addressed in the literature. Understanding and identifying the technological ways to assess pHEI is necessary for the future acceptance and large-scale use of these devices. The harmonization of these evaluation processes represents a key factor in building a still missing accepted framework to inform human–device contact safety. In this review, we identify, analyze, and discuss the metrics, testing procedures, and measurement devices used to assess pHEI in the last ten years. Furthermore, we discuss the role of pHEI in safety contact evaluation. We found a very heterogeneous panorama in terms of sensors and testing methods, which are still far from considering realistic conditions and use-cases. We identified the main gaps and drawbacks of current approaches, pointing towards a number of promising research directions. This review aspires to help the wearable robotics community find agreements on interaction quality and safety assessment testing procedures., This work was funded by the European project EXOSAFE (agreement No. RRD7218.02.02), an awarded project by the COVR project, funded by the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779966., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Testing Safety of Lower Limbs Exoskeletons: Current Regulatory Gaps

  • Massardi, Stefano
  • Pinto-Fernández, David
  • Veneman, Jan F.
  • Torricelli, Diego
Exoskeletons are a growing technology that is increasingly being studied and researched in various application domains. However, new technologies must fit into current regulations, which update more slowly than market needs. This paper analyses the main regulations and standards in which exoskeletons can fit, underlining the gaps and barriers that still exist and may hinder the smooth introduction of exoskeleton technology in the market., This research was supported by the ‘Realistic Trial Award’ EXOSAFE, funded by the European Union’s Horizon 2020 research and innovation programme under grant agreement No 779966 (COVR Project).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Characterization and Evaluation of Human–Exoskeleton Interaction Dynamics: A Review

  • Massardi, Stefano
  • Rodríguez-Cianca, David
  • Pinto-Fernández, David
  • Moreno, Juan Camilo
  • Lancini, Matteo
  • Torricelli, Diego
Exoskeletons and exosuits have witnessed unprecedented growth in recent years, especially in the medical and industrial sectors. In order to be successfully integrated into the current society, these devices must comply with several commercialization rules and safety standards. Due to their intrinsic coupling with human limbs, one of the main challenges is to test and prove the quality of physical interaction with humans. However, the study of physical human–exoskeleton interactions (pHEI) has been poorly addressed in the literature. Understanding and identifying the technological ways to assess pHEI is necessary for the future acceptance and large-scale use of these devices. The harmonization of these evaluation processes represents a key factor in building a still missing accepted framework to inform human–device contact safety. In this review, we identify, analyze, and discuss the metrics, testing procedures, and measurement devices used to assess pHEI in the last ten years. Furthermore, we discuss the role of pHEI in safety contact evaluation. We found a very heterogeneous panorama in terms of sensors and testing methods, which are still far from considering realistic conditions and use-cases. We identified the main gaps and drawbacks of current approaches, pointing towards a number of promising research directions. This review aspires to help the wearable robotics community find agreements on interaction quality and safety assessment testing procedures., This work was funded by the European project EXOSAFE (agreement No. RRD7218.02.02), an awarded project by the COVR project, funded by the European Union’s Horizon 2020 research and innovation programme under grant agreement No. 779966.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Relevance of hazards in exoskeleton applications: a survey-based enquiry

  • Massardi, Stefano
  • Pinto-Fernández, David
  • Babič, Jan
  • Dežman, Miha
  • Trošt, Andrej
  • Grosu, V.
  • Lefeber, D.
  • Rodriguez, C.
  • Bessler, J.
  • Schaake, L.
  • Prange-Lasonder, G.
  • Veneman, J.F.
  • Torricelli, Diego
Exoskeletons are becoming the reference technology for assistance and augmentation of human motor functions in a wide range of application domains. Unfortunately, the exponential growth of this sector has not been accompanied by a rigorous risk assessment (RA) process, which is necessary to identify the major aspects concerning the safety and impact of this new technology on humans. This situation may seriously hamper the market uptake of new products. This paper presents the results of a survey that was circulated to understand how hazards are considered by exoskeleton users, from research and industry perspectives. Our analysis aimed to identify the perceived occurrence and the impact of a sample of generic hazards, as well as to collect suggestions and general opinions from the respondents that can serve as a reference for more targeted RA. Our results identified a list of relevant hazards for exoskeletons. Among them, misalignments and unintended device motion were perceived as key aspects for exoskeletons’ safety. This survey aims to represent a first attempt in recording overall feedback from the community and contribute to future RAs and the identification of better mitigation strategies in the field., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. The work presented was developed within the project EXOSAFE and SALOEXO, an awarded project by the COVR European Project under grant agreement No 779966.
Archivo Digital UPM
Publication Tesis doctoral (DoctoralThesis)

Monitoring Human-Exoskeleton Interaction with Multimodal Interfaces and AI