Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 32
Encontrada(s) 1 página(s)

Biblos-e Archivo. Repositorio Institucional de la UAM
Publication Artículo científico (JournalArticle)

Artificial intelligence and machine learning applications in the Spanish nuclear field

  • Ramos, A.
  • Carrasco, A.
  • Fontanet, J.
  • Herranz, L. E.
  • Ramos Castro, Daniel
  • Díaz, M.
  • Zazo, J. M.
  • Cabellos, O.
  • Moraleda, J.
Machine Learning and Artificial Intelligence techniques are increasingly applied in the nuclear field. In this way, Spanish companies and research institutions have been developing different projects in the field of nuclear energy applying such techniques. A brief overview of some of these projects is presented, which cover areas as diverse as nuclear data, nuclear fuel manufacturing, simulation codes, fuel performance monitoring, nuclear inspection, and operation training. Among the techniques used to develop them are deep neural networks for building surrogate models, convolutional neural networks for computer vision, Bayesian networks and Gaussian processes for predictive models, and speech recognition with large language models, The ASSAS project receives funding from the European Union’s EURATOM Research and Training Programme (ID 101059682). Nuclear data activities at UPM are supported by the SANDA project (grant agreement 847552) of EU Horizon 2020 framework program
Docta Complutense
Publication Artículo científico (JournalArticle)

Design and commissioning of the miniBELEN neutron counter for the study of (α,n) reactions

  • Mont-Geli, N.
  • Tarifeño-Saldivia, A.
  • Pallàs, M.
  • Perea, A.
  • Fraile Prieto, Luis Mario
  • Cortés, G.
  • Briz Monago, José Antonio
  • Illana Sisón, Andrés
  • Martínez Nouvilas, Víctor
  • Udías Moinelo, José Manuel
The miniBELEN detector is a moderated neutron counter based on the use of 3He tubes and high-density polyethylene as moderator. The detector has been designed to have a neutron detection efficiency that is nearly independent from the initial neutron energy for (α,n) reactions with alpha-particle energies up to 15 MeV. In order to achieve that an innovative design methodology based on the use of cadmium neutron filters has been used. Monte Carlo calculations of the detector response have been validated using a 252Cf fission source. Measurements of the relatively well-known (α,n) thick target yields on aluminum have been found to be consistent with data from previous works. A method has been developed to correlate the counting rate ring ratios with the mean neutron energy and validated using previous time-of-flight measurements of the aluminum (α,n) spectra and with a 252Cf fission source.
Docta Complutense
Publication Contribución de congreso (ConferenceOutput)

miniBELEN: A modular neutron counter for (𝜶, 𝒏) reactions

  • Mont-Geli, N.
  • Tarifeño-Saldivia, A.
  • Fraile Prieto, Luis Mario
  • Viñals, S.
  • Perea, A.
  • Pallàs, M.
  • Cortés, G.
  • Briz Monago, José Antonio
  • Udías Moinelo, José Manuel
  • Villamarín, D.
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled m different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming to carry out measurements of (alpha, n) production yields, reaction cross-sections and neutron energy spectra. In this work we present and discuss several configurations of the miniBELEN detector. The experimental validation of the efficiency calculations using Cf-252 sources and the measurement of the (27)A1(alpha, n)P-30 reaction is also presented.
Digibug. Repositorio Institucional de la Universidad de Granada
Publication Artículo científico (JournalArticle)

Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF

  • Domingo Pardo, C.
  • García Infantes, F.
  • Porras Sánchez, José Ignacio|||0000-0003-0754-8717
  • Praena Rodríguez, Antonio Javier
  • Torres Sánchez, Pablo|||0000-0003-0608-5351
  • TOF Collaboration
This article presents a fewselected developments and future ideas related to the measurement of (n, γ ) data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with γ - ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate i neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area., European Research Council (ERC) 681740, Ministry of Science and Innovation, Spain (MICINN), Instituto de Salud Carlos III, Spanish Government PID2019-104714GBC21 FPA2017-83946-C2-1-P FIS2015-71688-ERC FPA-2016-77689-C2-1-R RTI2018-098117-B-C21, CSIC PIE-201750I26, European H2020 847552
Digibug. Repositorio Institucional de la Universidad de Granada
Publication Contribución de congreso (ConferenceOutput)

Measurement of the 235U(n,f) cross section relative to the 10B(n,α) reaction with Micromegas detectors at the CERN n_TOF facility: first results

  • Michalopoulou, Veatriki
  • Ogállar Ruiz, Francisco
  • Porras Sánchez, José Ignacio|||0000-0003-0754-8717
  • Praena Rodríguez, Antonio Javier
  • Torres Sánchez, Pablo|||0000-0003-0608-5351
  • n_TOF Collaboration
Funding from the European Union's Horizon 2020 research and innovation programme SANDA (Supplying Accurate Nuclear Data for energy and non-energy Applications) under grant agreement no 847552, is gratefully acknowledged., Neutron cross section measurements are often made relative to a neutron cross section standard. Thus, the accuracy of the neutron standards determines the best possible accuracy of the neutron measurements. The U-235(n,f) cross section is widely used as reference, while it is considered a standard at thermal point and between 0.15 to 200 MeV. For this reason, additional cross section data for the U-235(n,f) reaction are useful in order to improve the accuracy and to extend the energy range of the standard. In this work, preliminary results of the measurement of the 235U(n,f) cross-section relative to the standard (10) B(n,a) reaction are presented. The high accuracy measurement was performed at the experimental area EAR-1 of the n_TOF facility at CERN, aiming at covering the energy range from the thermal region up to approximately 100 keV. The samples were produced at JRC-Geel in Belgium, while the experimental setup was based on Micromegas detectors., European Union's Horizon 2020 research and innovation programme SANDA 847552
Digibug. Repositorio Institucional de la Universidad de Granada
Publication Contribución de congreso (ConferenceOutput)

Results of the 244Cm, 246Cm and 248Cm neutron-induced capture cross sections measurements at EAR1 and EAR2 of the n_TOF facility

  • Alcayne, V.
  • Ogállar Ruiz, Francisco
  • Porras Sánchez, José Ignacio|||0000-0003-0754-8717
  • Praena Rodríguez, Antonio Javier
  • Torres Sánchez, Pablo|||0000-0003-0608-5351
This work was supported in part by the I+D+i grant PGC2018-096717-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552)., Accurate neutron capture cross section data for minor actinides (MAs) are required to estimate the production and transmutation rates of MAs in light water reactors, critical fast reactors like Gen-IV systems, and other innovative reactor systems such as accelerator driven systems (ADS). In particular, Cm-244, Cm-246 and Cm-248 play a role in the transport, storage and transmutation of the nuclear waste of the current nuclear reactors, due to the contribution of these isotopes to the radiotoxicity, neutron emission, and decay heat in the spent nuclear fuel. Also, capture reactions in these Cm isotopes open the path for the formation of heavier elements. In this work, the results of the capture cross section measurement on Cm-244, Cm-246 and Cm-248 performed at the CERN n_TOF facility are presented. It is important to notice that the Cm samples used in the experiment at n_TOF have been used previously in an experiment at J-PARC, this experiment and the previous one done in the 70s with a nuclear explosion were the only previous capture experiments for these isotopes. At n_TOF, the capture cross section measurements of (244)cm, Cm-246 and Cm-248 were performed at the 20 m vertical flight path (EAR2) with three C6D6 total energy detectors. In addition, the cross section of Cm-244 was measured at the 185 m flight path (EAR1) with a Total Absorption Calorimeter (TAC). The combination of measurements in EAR1 and EAR2 has contributed to controlling and reducing the systematic uncertainties in the results. The compatibility of the different measurements performed and the techniques to obtain the results are presented in this paper as well as the procedure to obtain the resonance parameters., MCIN/AEI/10.13039/501100011033 I+D+i PGC2018-096717-B-C21, European Commission H2020 Framework Programme SANDA 847552
Digibug. Repositorio Institucional de la Universidad de Granada
Publication Contribución de congreso (ConferenceOutput)

A segmented total energy detector (sTED) for (n, γ) cross section measurements at n_TOF EAR2

  • Alcayne, V.
  • Andrzejewski, J.
  • Gawlik Ramiega, A.
  • Perkowski, J.
This work was supported in part by the I+D+i grant PGC2018-096717-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552)., The neutron time-of-flight facility n_TOF is characterised by its high instantaneous neutron intensity, high resolution and broad neutron energy spectra, specially conceived for neutron-induced reaction cross section measurements. Two Time-Of-Flight (TOR) experimental areas are available at the facility: experimental area 1 (EAR1), located at the end of the 185 m horizontal flight path from the spallation target, and experimental area 2 (EAR2), placed at 20 m from the target in the vertical direction. The neutron fluence in EAR2 is similar to 300 times more intense than in EARL in the relevant time-of-flight window. EAR2 was designed to carry out challenging cross-section measurements with low mass samples (approximately 1 mg), reactions with small cross-sections or/and highly radioactive samples. The high instantaneous fluence of EAR2 results in high counting rates that challenge the existing capture systems. Therefore, the sTED detector has been designed to mitigate these effects. In 2021, a dedicated campaign was done validating the performance of the detector up to at least 300 keV neutron energy. After this campaign, the detector has been used to perform various capture cross section measurements at n_TOF EAR2., MCIN/AEI/10.13039/501100011033 I+D+i PGC2018-096717-B-C21, European Commission H2020 Framework Programme SANDA 847552
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Research facilities and highlights at the Centro Nacional de Aceleradores (CNA)

  • Gómez-Camacho, Joaquín
  • García López, J.
  • López-Gutiérrez, J. M.
  • García-Tenorio, R.
  • Santos, F. J.
  • Chamizo, Elena
  • Ferrer, F. J.
  • Jiménez-Ramos, M. C.
  • Balcerzyk, Marcin
  • Fernández-Martínez, Begoña
Part of a collection: Focus Point on Small and Medium and Particle Accelerator Facilities in Europe, The Centro Nacional de Aceleradores is a user-oriented accelerator facility in Seville, Spain. Its main facilities are a 3 MV tandem accelerator, an 18 MeV proton Cyclotron, a tandetron used for AMS, a compact accelerator used for radiocarbon measurements, a Co irradiator and a PET/CT scanner. The technical specifications and research applications of these facilities are described. A neutron beam line associated to a charged pulsed beam in the tandem allows for time of flight measurements which determine the neutron energy. The use of an adequate stripper gas in the AMS tandetron permits to measure heavy radionuclides with very low detection levels, allowing to perform environmental studies using these radionuclides as tracers. The use of the microbeam in the tandem accelerator allows to apply the ion beam-induced current technique to investigate the spectroscopic properties and radiation hardness of different semiconductor detectors., Also the funding made available for infrastructures through the ICTS program of the Spanish ministry of science, making use of FEDER funds from the European Union. The continuous support of CNA patrons, the University of Seville, the Junta de Andalucía and CSIC is acknowledged. Private funds, through contracts with companies and institutions, such as Curium, Alter technologies, and the andalusian health service (SAS), made possible to maintain contracts of key personnel. We acknowledge the funding of projects by the European Union, H2020-847594, H2020-654002, H2020-847552, H2020-847594 , by the Spanish ministry of science RTI2018-098117-B-C21, RTC-2017-6369-3, EQC2018-004193-P, EQC2018-004095-P, EQC2018-004166-P, PGC2018-094546-B-I00, and by the Junta de Andalucía FEDER progrem US-1261006, US-1263369, P18-RT-1900.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Production yields at the distal fall-off of the β+ emitters 11C and 13N for in-vivo range verification in proton therapy

  • Rodríguez González, M. Teresa
  • Guerrero, C.
  • Jiménez-Ramos, M. C.
  • Lerendegui-Marco, J.
  • Millán Callado, María de los Ángeles
  • Parrado-Gallego, Ángel
  • Gómez-Camacho, Joaquín
  • Quesada, José Manuel
In proton therapy, Positron Emission Tomography (PET) range verification relies on the comparison of the measured and estimated activity distributions from β emitters produced by the proton beam in the patient. The accuracy of the estimated activity distributions is basically that of the underlying reaction cross section data. In this context, we have developed a new method for measuring β production yields combining the multi-foil technique with a clinical PET scanner, resulting in energy differential cross sections from a single irradiation. The method has been applied to the production of C11 (t = 20.36 min) and Ny13 (t = 9.97 min), the main candidates for off-line PET range verification, in carbon, nitrogen and oxygen, the main elements of the human body. The energy range studied with the 18 MeV CNA cyclotron corresponds to the distal fall-off of the activity curve, i.e. near the Bragg peak., This project has received funding from the Spanish Ministry of Economy and Competitiveness projects RYC-2014-15271, FPA2016-77689-C2-1-R and RTI2018-098117-B-C21, from the European H2020-847552 (SANDA) and the V Plan Propio de Investigación Programme from the University of Sevilla. T. Rodriguez-Gonzalez acknowledges the Spanish FPI predoctoral grant.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Hybrid in-beam PET- and Compton prompt-gamma imaging aimed at enhanced proton-range verification

  • Balibrea, Javier
  • Lerendegui-Marco, J.
  • Ladarescu, I.
  • Guerrero, C.
  • Rodríguez González, M. Teresa
  • Jiménez-Ramos, M. C.
  • Fernández-Martínez, Begoña
  • Domingo Pardo, César
We report on a hybrid in-beam PET and prompt-gamma Compton imaging system aimed at quasi real-time ion-range verification in proton-therapy treatments. Proof-of-concept experiments were carried out at the radiobiology beam line of the CNA cyclotron facility using a set of two synchronous Compton imagers and different target materials. The time structure of the 18 MeV proton beam was shaped with a series of beam-on and beam-off intervals, thereby mimicking a pulsed proton beam on a long time scale. During beam-on intervals, Compton imaging was performed utilizing the high energy γ-rays promptly emitted from the nuclear reactions occurring in the targets. In the course of the beam-off intervals in situ positron-emission tomography was accomplished with the same imagers using the β decay of activated nuclei. The targets used were stacks of different materials covering also various proton ranges and energies. A systematic study on the performance of these two complementary imaging techniques is reported and the experimental results interpreted on the basis of Monte Carlo calculations. The results demonstrate the possibility to combine both imaging techniques in a concomitant way, where high-efficiency prompt-gamma imaging is complemented with the high spatial accuracy of PET. Empowered by these results we suggest that a pulsed beam with a suitable duty cycle, in conjunction with in situ Compton- and PET-imaging may help to attain complementary information and quasi real-time range monitoring with high accuracy., Open Access funding provided thanks to the CRUE-CSIC agreement with springer nature. This work has been carried out in the framework of a project funded by the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (ERC Consolidator Grant project HYMNS, with grant agreement No.~681740). The authors acknowledge support from the Spanish Ministerio de Ciencia e Innovación under grants PID2019-104714GB-C21, FPA2017-83946-C2-1-P, FIS2015-71688-ERC, FPA2016-77689-C2-1-R, RTI2018-098117-B-C21, CSIC for funding PIE-201750I26 and from the European H2020-847552 (SANDA). This work was partially supported by Generalitat Valenciana PROMETEO/2019/007. J. Balibrea-Correa is supported by grant ICJ220-045122-I funded by MCIN/AEI/10.13039/501100011033 and by European Union NextGenerationEU/PRTR. J. Lerendegui-Marco is supported by grant FJC2020-044688-I funded by MCIN/AEI/10.13039/501100011033 and by European UnionNextGenerationEU/PRTR.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Neutron capture measurements with high efficiency detectors and the Pulse Height Weighting Technique

  • Mendoza, E.
  • Alcayne, V.
  • Cano-Ott, D.
  • González-Romero, E.
  • Martínez, T.
  • Pérez de Rada, A.
  • Sánchez-Caballero, A.
  • Balibrea, Javier
  • Domingo Pardo, César
  • Lerendegui-Marco, J.
  • Calviño, F.
  • Guerrero, C.
Neutron capture cross section measurements in time-of-flight facilities are usually performed by detecting the prompt γ-rays emitted in the capture reactions. One of the difficulties to be addressed in these measurements is that the emitted γ-rays may change with the neutron energy, and therefore also the detection efficiency. To deal with this situation, many measurements use the so called Total Energy Detection (TED) technique, usually in combination with the Pulse Height Weighting Technique (PHWT). With it, it is sought that the detection efficiency depends only on the total energy of the γ-ray cascade, which does not vary much with the neutron energy. This technique was developed in the 1960s and has been used in many neutron capture experiments to date. One of the requirements of the technique is that γ-ray detectors have a low efficiency. This has meant that the PHWT has been used with experimental setups with low detection efficiencies. However, this condition does not have to be fulfilled by the experimental system as a whole. The main goal of this work is to show that it is possible to measure with a high efficiency detection system that uses the PHWT, and how to analyze the measured data., This work was supported in part by the I+D+i grant PGC2018- 096717-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Production of 11C, 13N and 15O in proton-induced nuclear reactions up to 200 MeV

  • Rodríguez González, M. Teresa
  • Guerrero, C.
  • Bäcker, C. M.
  • Bauer, J.
  • Bäumer, C.
  • Brons, S.
  • Jentzen, W.
  • Jiménez-Ramos, M. C.
  • Millán Callado, María de los Ángeles
  • Schömers, C.
  • Timmermann, B.
  • Quesada, José Manuel
  • Capote-Noy, Roberto
Production cross sections of light positron emitters 11C (t1/2=20.36 min), 13N (t1/2=9.97 min) and 15O (t1/2=122 s) have been measured for proton-induced reactions on the main relevant constituents of the human body (C, N and O) from threshold up to 200 MeV of proton incident energy. This has been accomplished by means of two complementary experiments at the clinical proton treatment centers WPE (Essen) and HIT (Heidelberg), both in Germany. In the first case, the multi-foil activation technique was combined with PET imaging, a methodology previously developed at CNA (Seville, Spain). In the second experiment, aimed at energies below 50 MeV, the activation of single foils was measured with conventional LaBr3 detectors. In both cases the IAEA monitor reaction natCu(p,x)63Zn data was used for validation purposes. The most complete and accurate set of excitation functions for the production of light-positron emitters 11C, 13N and 15O in proton induced reactions on human tissue up to 200 MeV is presented. These data are needed for nuclear reaction model development and are extremely important to improve the accuracy of the PET range verification in proton radiotherapy. Seven excitation functions have been measured: 12C(p,x)11C, 14N(p,x)11C, 14N(p,x)13N, 14N(p,γ)15O, 16O(p,x)11C, 16O(p,x)13N and 16O(p,x)15O up to 200 MeV of proton incident energy., The research work presented herein has received funding from the Spanish Ministry of Economy and Competitiveness projects under grants no RYC-2014-15271, FPA2016-77689-C2-1-R and RTI2018-098117-B-C21, from the EC project H2020-847552 (SANDA), from the “Consejería de Economía y Conocimiento de la Junta de Andalucía” project under grant no. P18-RT-1900, from the Regional Ministry of Economy, Knowledge, Business and University/FEDER funds under grant no. US-1380791 and from the “V Plan Propio de Investigación (V PPIT-US)” programme from the University of Sevilla. M.C. Jiménez Ramos acknowledges the support to this work through a VI PPIT-US contract. J. Bauer acknowledges funding from the Universtity of Heidelberg as Olympia-Morata fellow. T. Rodriguez-Gonzalez acknowledges the Spanish FPI PhD grant associated to the project FPA2016-77689-C2-1-R., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Measurement of the neutron-induced fission cross section of Th 230 at the CERN n_TOF facility

  • Michalopoulou, Veatriki
  • Babiano-Suárez, V.
  • Caballero Ontanaya, Luis
  • Domingo Pardo, César
  • Ladarescu, I.
  • Taín, José Luis
The neutron-induced fission cross section of Th230 has been measured at the neutron time-of-flight facility n_TOF located at CERN. The experiment was performed at the experimental area EAR-1 with a neutron flight path of 185 m, using Micromegas detectors for the detection of the fission fragments. The Th230(n,f) cross section was determined relative to the U235(n,f) one, covering the energy range from the fission threshold up to 400 MeV. The results from the present work are compared with existing cross-section datasets and the observed discrepancies are discussed and analyzed. Finally, using the code empire 3.2.3 a theoretical study, based on the statistical model, was performed leading to a satisfactory reproduction of the experimental results with the proper tuning of the respective parameters, while for incident neutron energy beyond 200 MeV the fission of Th230 was described by Monte Carlo simulations.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Improving fission-product decay data for reactor applications: part I—decay heat

  • Nichols, A. L.
  • Dimitriou, P.
  • Algora, Alejandro
  • Fallot, M.
  • Giot, L.
  • Kondev, F.G.
  • Yoshida, T.
  • Karny, M.
  • Mukherjee, G.
  • Rasco, B. C.
  • Rykaczewski, K. P.
  • Sonzogni, A.A.
  • Taín, José Luis
Effort has been expended to assess the relative merits of undertaking further decay-data measurements of the main fission-product contributors to the decay heat of neutron-irradiated fissionable fuel and related actinides by means of Total Absorption Gamma-ray Spectroscopy (TAGS - sometimes abbreviated to TAS) and Discrete Gamma-ray Spectroscopy (DGS). This review has been carried out following similar work performed under the auspices of OECD/WPEC-Subgroup 25 (2005–2007) and the International Atomic Energy Agency (2009, 2014), and various highly relevant TAGS measurements completed as a consequence of such assessments. We present our recommendations for new decay-data evaluations, along with possible requirements for total absorption and discrete high-resolution gamma-ray spectroscopy studies that cover approximately 120 fission products and various isomeric states., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF

  • Domingo Pardo, César
  • Babiano-Suárez, V.
  • Balibrea, Javier
  • Caballero Ontanaya, Luis
  • Ladarescu, I.
  • Lerendegui-Marco, J.
  • Tain, José Luis
  • Tarifeño-Saldivia, A.
  • n_TOF Collaboration
This article presents a few selected developments and future ideas related to the measurement of (n, γ) data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with γ-ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate i neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Measurement of 242Pu(n,f) in the 1-2 MeV energy range

  • Mathieu, Ludovic
  • Aïche, Mourad
  • Marini, Paola
  • Bouland, Olivier
  • Chatel, Carole
  • Czajkowski, Serge
  • Kattikat-Melcom, Deby
  • Kurtukian-Nieto, Teresa
  • Oberstedt, Stephan
  • Tsekhanovich, Igor
8 pages, 5 figures, The design of new generation fast nuclear reactors requires highly accurate cross-section measurements in the MeV energy region. The 242Pu fission cross section is of particular interest for Pu incineration and nuclear waste production. There are discrepancies around 1 MeV incident neutron energy between libraries and among experimental data. Some data suggest the presence of a strong structure between 1 and 1.2 MeV whereas it is barely visible on some other data and its shape is very different among evaluations. The large majority of the 242Pu(n,f) measurements have been carried out with respect to the 235U(n,f) secondary-standard cross section. This introduces a strong correlation between measurements from different research teams. Moreover, this reference cross section exhibits structures, in particular a steep increase of +10% at 1 MeV. Therefore, we aim to re-measure the 242Pu(n,f) cross section relative to the primary-standard 1H(n,n)p cross section, by using a proton recoil detector. This standard has a very high accuracy (0.4%), is not used for other 242Pu measurements, and is structureless. An experiment has been carried out in October 2022 at the MONNET facility in JRC Geel, with incident neutron energies from 0.9 MeV to 2.0 MeV. The experimental setup will be presented, and the analysis procedure will be detailed., We wish to acknowledge the MONNET team for providing support and a high quality beam during the experiment. This work is supported by the European Atomic Energy Community (EURATOM) under the European Union’s Horizon 2020 SANDA, grant agreement No 847552., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

β-delayed neutron spectroscopy of As 85,86 with MONSTER at IGISOL

  • Pérez De Rada Fiol, A.
  • Martínez, T.
  • Cano-Ott, D.
  • Penttilä, H.
  • Agramunt, Jorge
  • Alcayne, V.
  • Algora, Alejandro
  • Alhomaidhi, S.
  • Äaö, J.
  • Banerjee, K.
  • Beliuskina, O.
  • Benito, J.
  • Bhattacharya, C.
  • Calviño, F.
  • Cortés, G.
  • De Groote, R. P.
  • De Roubin, A.
  • Delafosse, C.
  • Domingo Pardo, César
  • Geldhof, S.
  • Gins, W.
  • Hukkanen, M.
  • Jokinen, A.
  • Kankainen, A.
  • Lerendegui-Marco, J.
  • Llanes Gamonoso, J.
  • Matea, I.
  • Mendoza, E.
  • Mistry, A. K.
  • Nesterenko, D. A.
  • Plaza, J.
  • Pohjalainen, I.
  • Rinta-Antila, S.
  • Roy, P.
  • Sanchez-Caballero, A.
  • Taín, José Luis
  • Villamarín, D.
  • Vilen, M.
10 pages, 11 figures, revised version submitted to Physical Review C, The β-delayed neutron emission in the As85,86β decays has been measured at the Ion Guide Isotope Separator On Line facility of the Accelerator Laboratory of the University of Jyväskylä. The complete β decays have been studied with a complex setup that consists of a plastic scintillator for β particles, MONSTER-the MOdular Neutron time-of-flight SpectromeTER-for neutrons, and a high-purity germanium and four LaBr3 crystals for γ rays. The β-delayed neutron energy distributions have been determined by unfolding the time-of-flight spectra with an innovative methodology based on the iterative Bayesian unfolding method and accurate Monte Carlo simulations. The results obtained for As85 are in excellent agreement with the existing evaluated data, validating the proposed methodology. In the case of As86, a stronger neutron intensity at higher energies than previously predicted is discovered., This work was partially supported by the I+D+i Grants No. FPA2016-76765-P, No. PGC2018-096717-B-C21, and No. PID2022-142589OB-I00 funded by MCIN/AEI/10.13039/501100011033, and by the European Commission H2020 Framework Programme project SANDA (Grant Agreement No. ID: 847552). This project has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement no. 771036 (ERC CoG MAIDEN) and the Research Council of Finland Projects No. 275389, No. 284516, No. 312544, and No. 354968. This work was partially funded by Spanish MCIN/AEI/10.13039/501100011033 under Grants No. RTI2018-098868-B-I00 and No. PID2021-126998OB-I0. J.B. acknowledges support from the UCM Spanish MIU and EU Next-Generation funds under Grants No. CT27/16-CT28/16 and No. CT31/21., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Design and commissioning of the miniBELEN neutron counter for the study of (α,n) reactions

  • Mont-Geli, Nil
  • Tarifeño-Saldivia, A.
  • Pallàs, Max
  • Perea, Ángel
  • Fraile, Luis M.
  • Cortés, Guillem
  • Viñals, S.
  • Taín, José Luis
  • García, Gastón
  • Soler, Daniel
  • Alonso-Sañudo, Odette
  • Borge, María José
  • Briz, José Antonio
  • Calviño, Francisco
  • Cano Ott, Daniel
  • Blas, Alfredo de
  • Fernández-Martínez, Begoña
  • García, Roger
  • García Távora, Vicente
  • González-Romero, Enrique M.
  • Guerrero, C.
  • Illana, A.
  • Martínez, Trino
  • Martínez-Nouvilas, Víctor
  • Mendoza, Emilio
  • Nácher, Enrique
  • Nerio, A. R.
  • Plaza, Julio
  • Tengblad, Olof
  • Udías, J. M.
The miniBELEN detector is a moderated neutron counter based on the use of 3He tubes and high-density polyethylene as moderator. The detector has been designed to have a neutron detection efficiency that is nearly independent from the initial neutron energy for (α, n) reactions with alpha-particle energies up to 15 MeV. In order to achieve that an innovative design methodology based on the use of cadmium neutron filters has been used. Monte Carlo calculations of the detector response have been validated using a 252Cf fission source. Measurements of the relatively well-known (α, n) thick target yields on aluminum have been found to be consistent with data from previous works. A method has been developed to correlate the counting rate ring ratios with the mean neutron energy and validated using previous time-of-flight measurements of the aluminum (α, n) spectra and with a 252Cf fission source., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work has been supported by the Spanish government grants FPA2017-83946-C2-1 and C2-2, PID2019-104714GB-C21 and C22, PID2021-126998OB-I00, and RTI2018-098868-B-I00; the Generalitat Valenciana grant PROMETEO/2019/007; the SANDA project funded under the H2020 EURATOM-1.1 grant 847552; the MRR (Recuperation and Resilience Mechanism) cofinanced by the Generalitat de Catalunya; the Spanish Ministerio de Ciencia e Investigación (MCIN); and the European Union (EU). The authors acknowledge the support from Centro de Micro-Análisis de Materiales (CMAM)—Universidad Autónoma de Madrid (UAM) for the beam time proposals with codes P01075, P01156, and P01302 and its technical staff for their contribution to the operation. Author Nil Mont-Geli also acknowledges Banco de Santander and grant 2021 FISDU 00368 financed by the Secretaria d’Universitats i Recerca del Departament d’Empresa i Coneixement de la Generalitat de Catalunya., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Multi-section fission ionization chamber for measurement of 239 Pu (n, y) reaction in fission tagging method

  • Perkowski, Jaroslaw
  • Alcayne Aicua, Víctor
  • Andrzejewski, Józef
  • Cano Ott, Daniel
  • Gawlik Ramiega, Aleksandra
  • Mendoza, Emilio
  • Sánchez Caballero, Adrián
  • Sibbens, Geodele
  • Vanleeuw, David
  • Aberle, Oliver
  • Altieri, Saverio
  • Amaducci, Simone
  • Babiano Suárez, Víctor
  • Bacak, Michael
  • Balibrea Correa, Javier
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
The 239 Pu (n, y) reaction cross section is very important for operation of both thermal and fast reactors, when loaded with MOX fuels. According to the NEA/OECD High Priority Request List the precision of cross section data for this reaction should be improved. The cross section of (n, f) reaction is much higher compared to (n, y) for this isotope. In such conditions the fission tagging technique could be applied to identify the fission background. In the past, this technique was successfully used for capture measurements at the n_TOF facility at CERN. The multi-section fission ionization chamber was constructed and used in the combination with Total Absorption Calorimeter (TAC) for detecting gamma rays for the precise measurement of 239 Pu (n, y) reaction cross section at the n_TOF facility., We acknowledge support of Narodowe Centrum Nauki (NCN), Poland (Grant No. UMO-2021/41/B/ST2/00326) and UE in the frame of the SANDA grant nr 847552 (Horizon 2020 project) and project of Ministry of Science and Higher Education of Poland nr 450734/PnH 2/2019 and Projekt Miedzynarodowy Wspolfinansowany Nr W93/H2019/Euratom/2019 (5099/H2020-Euratom/2020/2) and also University of Lodz under the grant (9/IDUB/MLOD/2021). This work was partially supported by PGC2018-096717- B-C21, and PID2022- 142589OB-I00 funded by MCIN/AEI/10.13039/501100011033 and also by Croatian Science Foundation project IP-2022-10-3878. The experimental data used in this research were generated through ac- cess to the GELINA facility under the Framework for access to the Joint Research Centre physical Research Infrastructures of the Euro- pean Commission (CHARPU project, Research Infrastructure Access Agreement N◦ 36225/2/2021-1-RD-EUFRAT-GELINA)., Article signat per 136 autors/es: J. Perkowski, V. Alcayne, J. Andrzejewski, D. Cano-Ott, A. Gawlik-Ramięga, E. Mendoza, A. Sánchez-Caballero, G. Sibbens, D. Vanleeuw, O. Aberle, S. Altieri, S. Amaducci, V. Babiano-Suarez, M. Bacak, J. Balibrea Correa, C. Beltrami, S. Bennett, A.P. Bernardes, E. Berthoumieux, R. Beyer, M. Boromiza, D. Bosnar, M. Caamaño, F. Calviño, M. Calviani, A. Casanovas, D.M. Castelluccio, F. Cerutti, G. Cescutti, S. Chasapoglou, E. Chiaveri, P. Colombetti, N. Colonna, P. Console Camprini, G. Cortés, M.A. Cortés-Giraldo, L. Cosentino, S. Cristallo, S. Dellmann, M. Di Castro, S. Di Maria, M. Diakaki, M. Dietz, C. Domingo-Pardo, R. Dressler, E. Dupont, I. Durán, Z. Eleme, S. Fargier, B. Fernández, B. Fernández-Domínguez, P. Finocchiaro, S. Fiore, V. Furman, F. García-Infantes, G. Gervino, S. Gilardoni, E. González-Romero, C. Guerrero, F. Gunsing, C. Gustavino, J. Heyse, W. Hillman, D.G. Jenkins, E. Jericha, A. Junghans, Y. Kadi, K. Kaperoni, G. Kaur, A. Kimura, I. Knapová, M. Kokkoris, Y. Kopatch, M. Krtička, N. Kyritsis, I. Ladarescu, C. Lederer-Woods, J. Lerendegui-Marco, G. Lerner, A. Manna, T. Martínez, A. Masi, C. Massimi, P. Mastinu, M. Mastromarco, E.A. Maugeri, A. Mazzone, A. Mengoni, V. Michalopoulou, P.M. Milazzo, R. Mucciola, F. Murtas, E. Musacchio-Gonzalez, A. Musumarra, A. Negret, A. Pérez de Rada Fiol, P. Pérez-Maroto, N. Patronis, J.A. Pavón-Rodríguez, M.G. Pellegriti, C. Petrone, E. Pirovano, J. Plaza del Olmo, S. Pomp, I. Porras, J. Praena, J.M. Quesada, R. Reifarth, D. Rochman, Y. Romanets, C. Rubbia, M. Sabaté-Gilarte, P. Schillebeeckx, D. Schumann, A. Sekhar, A.G. Smith, N.V. Sosnin, M.E. Stamati, A. Sturniolo, G. Tagliente, A. Tarifeño-Saldivia, D. Tarrío, P. Torres-Sánchez, E. Vagena, S. Valenta, V. Variale, P. Vaz, G. Vecchio, D. Vescovi, V. Vlachoudis, R. Vlastou, A. Wallner, P.J. Woods, T. Wright, R. Zarrella, P. Žugec.
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

miniBELEN: a modular neutron counter for (a, n) reactions

  • Mont i Geli, Nil|||0000-0003-4249-7281
  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
  • Fraile, L. M.
  • Viñals Onsens, Silvia
  • Perea Martínez, Ángel
  • Pallàs i Solís, Max|||0000-0001-6137-0812
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
  • Nacher González, Enrique
  • Taín Enríquez, José Luis|||0000-0002-3263-6965
  • Alcayne Aicua, Víctor
  • Algora Wesolowsk, Alejandro
  • Balibrea Correa, Javier
  • Benito García, Jaime
  • García Borge, María José
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Blas del Hoyo, Alfredo de|||0000-0002-0868-9514
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled in different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming to carry out measurements of (a, n) production yields, reaction cross-sections and neutron energy spectra. In this work we present and discuss several configurations of the miniBELEN detector. The experimental validation of the efficiency calculations using 252Cf sources and the measurement of the 27Al(a, n) 30P reaction is also presented., This work has been supported by the Spanish Ministerio de Economía y Competitividad under grants FPA2017-83946- C2-1 & C2-2 and PID2019-104714GB-C21 & C22, the Generalitat Valenciana Grant PROMETEO/2019/007, both cofounded by FEDER (EU), and the SANDA project funded under H2020-EURATOM-1.1 Grant No. 847552. The authors acknowledge the support from Centro de Microanálisis de Materiales (CMAM) - Universidad Autónoma de Madrid, for the beam time proposal (Comissioning of neutron detector systems for (a,݊n) reaction measurements) with code P01156, and its technical staff for their contribution to the operation of the accelerator., Article signat per 41 autors/es: N. Mont-Geli, A. Tarifeño-Saldivia, L.M. Fraile, S. Viñals, A. Perea, M. Pallàs, G. Cortés, E. Nácher, J.L. Tain, V. Alcayne, A. Algora, J. Balibrea-Correa, J. Benito, M.J.G. Borge, J.A. Briz, F. Calviño, D. Cano-Ott, A. De Blas, C. Domingo-Pardo, B. Fernández, R. Garcia, G. García, J. Gómez-Camacho, E.M. González-Romero, C. Guerrero, J. Lerendegui-Marco, M. Llanos, T. Martínez, E. Mendoza, J.R. Murias, S.E.A. Orrigo, A. Pérez de Rada, V. Pesudo, J. Plaza, J.M. Quesada, A. Sánchez, V. Sánchez-Tembleque, R. Santorelli, O. Tengblad, J.M. Udías and D. Villamarín.
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Measurement of the 244Cm neutron capture cross section at the n_TOF facility at CERN

  • Alcayne Aicua, Víctor
  • Kimura, Atsushi
  • Mendoza Cembranos, Emilio
  • Cano Ott, Daniel
  • Aberle, Oliver
  • Alvarez Velarde, Francisco
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
Accurate neutron capture cross section data for minor actinides are essential for the safe and efficient management of high level radioactive waste produced during the operation of nuclear reactors. In particular, 244Cm, with a half-life of 18.11 years, dominates neutron emission in spent fuel and also contributes significantly to the decay heat and radiotoxicity. Furthermore, neutron capture on 244Cm opens the pathway for the formation of heavier isotopes such as Bk, Cf, and other Cm isotopes. Sensitivity studies for present and future nuclear reactors have highlighted the need to reduce the uncertainties in the 244Cm capture cross section. Experimental data on the capture cross section of this isotope are scarce due to the challenges associated with its measurements. Prior to the presented measurement and two recent measurements conducted at J-PARC, only one set of data for the 244Cm capture cross section existed, obtained in 1969 during an underground nuclear explosion experiment. The capture cross section of 244Cm has been measured at the n_TOF facility at CERN with three different experimental setups: one at Experimental Area 1 (EAR1) using the Total Absorption Calorimeter and two measurements at Experimental Area 2 (EAR2) with C D detectors, employing two different samples. The results from these three measurements were found to be compatible and then combined. In total, 17 resonances of 244Cm were measured at n_TOF below 300 eV. The radiative kernels obtained in this measurement are in good agreement with JENDL-4.0 for the majority of the resonances. Additionally, they are compatible with the recent JENDL-5 library below 50 eV, while at higher energies, the majority of radiative kernels from this evaluation based on the recent measurement by Kawase et al., are not compatible. Additionally, the 244Cm samples also contained 240Pu. Resonances of this isotope were analyzed in the energy range between 20 and 180 eV, and the results were found to be consistent with previous measurements and evaluations, that enhances confidence in the 244Cm results., This work was supported in part by the I+D+i grant PGC2018-096717-B-C21 funded by MCIN/AEI/10.13039/501100011033, by project PID2021-123100NB-I00 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE, by project PCI2022-135037-2 funded by MCIN/AEI/10.13039/501100011033/ and European Union NextGenerationEU/PRTR, by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552), Croatian Science Foundation project IP-2022-10-3878 and by funding agencies of the n_TOF participating institutions., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Low-uncertainty measurement of the 239Pu(n,f) cross section at n_TOF in a very broad energy range from 0.02 eV up to 10 MeV

  • Sánchez Caballero, Adrián
  • Cano Ott, Daniel
  • Mendoza Cembranos, Emilio
  • Alcayne Aicua, Víctor
  • Andrzejewski, Józef
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
The 239Pu(n,f) cross section was measured with uncertainties below 4 % from 20 meV up to 10 MeV of neutron energy at CERN’s n_TOF facility using a novel fission fragment detector with a 185.59 m flight path. Measured cross section was normalized to 1059(6) eV¿·¿b in the 9–20 eV energy range, and is consistent within uncertainties with the standard thermal value and the IAEA reference 239Pu(n,f) cross section. Experimental key values include the integral ratio defined by Duran et al. 2024 and the spectrum averaged cross section in 252Cf(sf) reference neutron field of 1802(40) mb., In memory of Koen Vanaken, whose invaluable contributions and dedication to the Fuel Materials laboratories of SCK CEN will always be remembered. We wish to acknowledge André Moens (formerly member of the JRC-Geel Target Preparation laboratory, now retired) for his important contribution to the preparation of the 239Pu samples. Funding for this project was provided by the Euratom research and training program 2014–2018 under grant agreement no 847594 (ARIEL). Additional support came from the European Commission through the H2020 Framework Programme under grant agreement no 847552 (SANDA) and the project 36225/2/2021-1-RD-EUFRAT-GELINA (CHARPU), as well as from I+D+i grants PGC2018-096717-B-C21, PID2021-123100NB-I00, PID2022-142589OB-I00, and PDC2021-120828-I00 funded by MCIN/AEI/10.13039/501100011033. Furthermore, this research received partial funding from the National Science Centre in Poland (grant no UMO-2021/41/B/ST2/00326). The support of the funding agencies of all other participating institutes is also appreciated., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A segmented total energy detector (sTED) optimized for (n, ¿) cross-section measurements at n_TOF EAR2

  • Alcayne Aicua, Víctor
  • Cano Ott, Daniel
  • García Alvarado, Jose Maria
  • González Romero, Enrique Miguel
  • Martínez, T.
  • Pérez de Rada Fiol, Alberto
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron- induced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of ~ 4 · 107 neutrons per nominal proton pulse, which is ~50 times higher than the one of Experimental ARea 1 (EAR1) of ~ 8 · 105 neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detector’s response, by reducing the active volume per module and by using a photo-multiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to ¿-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at n_TOF EAR2., This work was supported in part by the I+D+i grant PGC2018- 096717-B-C21 funded by MCIN/AEI/10.13039/501100011033, by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552) and by funding agencies of the n_TOF participating institutions., Article signat per 136 autors/es: V. Alcayne, D. Cano-Ott, J. Garcia, E. González-Romero, T. Martínez, A. Pérez de Rada, J. Plaza, A. Sánchez-Caballero, J. Balibrea-Correa, C. Domingo-Pardo, J. Lerendegui-Marco, A. Casanovas, F. Calviño, O. Aberle, S. Altieri, S. Amaducci, J. Andrzejewski, V. Babiano-Suarez, M. Bacak, C. Beltrami, S. Bennett, A.P. Bernardes, E. Berthoumieux, R. Beyer , M. Boromiza, D. Bosnar, M. Caamaño, M. Calviani, D.M. Castelluccio, F. Cerutti, G. Cescutti, S. Chasapoglou, E. Chiaveri, P. Colombetti, N. Colonna, P. Console Camprini, G. Cortés, M.A. Cortés-Girald, L. Cosentino, S. Dellmann, M. Di Castro, S. Di Maria, M. Diakaki, M. Dietz, R. Dressler, E. Dupont, I. Durán, Z. Eleme, S. Fargier, B. Fernández, B. Fernández-Domínguez, P. Finocchiaro, S. Fiore, V. Furman, F. García-Infantes, A. Gawlik-Ramiega, G. Gervino, S. Gilardoni, C. Guerrero, F. Gunsing, C. Gustavino, J. Heyse, W. Hillman, D.G. Jenkins, E. Jericha, A. Junghans, Y. Kadi, K. Kaperoni, G. Kaur, A. Kimura, I. Knapová, M. Kokkoris, Y. Kopatch, M. Krtička, N. Kyritsis, I. Ladarescu, C. Lederer-Woods, G. Lerner, A. Manna, A. Masi, C. Massimi, P. Mastinu, M. Mastromarco, E.A. Maugeri, A. Mazzone, E. Mendoza, A. Mengoni, V. Michalopoulou, P.M. Milazzo, R. Mucciola, F. Murtas, E. Musacchio-Gonzalez, A. Musumarra, A. Negret, P. Pérez-Maroto, N. Patronis, J.A. Pavón-Rodríguez, M.G. Pellegriti, J. Perkowski, C. Petrone, L. Piersanti, E. Pirovano, S. Pomp, I. Porras, J. Praena, J.M. Quesada, R. Reifarth, D. Rochman, Y. Romanets, C. Rubbia, M. Sabaté-Gilarte, P. Schillebeeckx, D. Schumann, A. Sekhar, A.G. Smith, N.V. Sosnin, M. Spelta, M.E. Stamati, A. Sturniolo, G. Tagliente, A. Tarifeño-Saldivia, D. Tarrío, P. Torres-Sánchez, E. Vagena, S. Valenta, V. Variale, P. Vaz, G. Vecchio, D. Vescovi, V. Vlachoudis, R. Vlastou, A. Wallner, P.J. Woods, T. Wright, R. Zarrella, P. Žugec.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Multi-section fission ionization chamber for measurement of 239 Pu (n, y) reaction in fission tagging method

  • Perkowski, Jaroslaw
  • Alcayne Aicua, Víctor
  • Andrzejewski, Józef
  • Cano Ott, Daniel
  • Gawlik Ramiega, Aleksandra
  • Mendoza, Emilio
  • Sánchez Caballero, Adrián
  • Sibbens, Geodele
  • Vanleeuw, David
  • Aberle, Oliver
  • Altieri, Saverio
  • Amaducci, Simone
  • Babiano Suárez, Víctor
  • Bacak, Michael
  • Balibrea Correa, Javier
  • Calviño Tavares, Francisco
  • Casanovas Hoste, Adrià
  • Cortés Rossell, Guillem Pere
  • Tarifeño Saldivia, Ariel Esteban
The 239 Pu (n, y) reaction cross section is very important for operation of both thermal and fast reactors, when loaded with MOX fuels. According to the NEA/OECD High Priority Request List the precision of cross section data for this reaction should be improved. The cross section of (n, f) reaction is much higher compared to (n, y) for this isotope. In such conditions the fission tagging technique could be applied to identify the fission background. In the past, this technique was successfully used for capture measurements at the n_TOF facility at CERN. The multi-section fission ionization chamber was constructed and used in the combination with Total Absorption Calorimeter (TAC) for detecting gamma rays for the precise measurement of 239 Pu (n, y) reaction cross section at the n_TOF facility., We acknowledge support of Narodowe Centrum Nauki (NCN), Poland (Grant No. UMO-2021/41/B/ST2/00326) and UE in the frame of the SANDA grant nr 847552 (Horizon 2020 project) and project of Ministry of Science and Higher Education of Poland nr 450734/PnH 2/2019 and Projekt Miedzynarodowy Wspolfinansowany Nr W93/H2019/Euratom/2019 (5099/H2020-Euratom/2020/2) and also University of Lodz under the grant (9/IDUB/MLOD/2021). This work was partially supported by PGC2018-096717- B-C21, and PID2022- 142589OB-I00 funded by MCIN/AEI/10.13039/501100011033 and also by Croatian Science Foundation project IP-2022-10-3878. The experimental data used in this research were generated through ac- cess to the GELINA facility under the Framework for access to the Joint Research Centre physical Research Infrastructures of the Euro- pean Commission (CHARPU project, Research Infrastructure Access Agreement N◦ 36225/2/2021-1-RD-EUFRAT-GELINA)., Article signat per 136 autors/es: J. Perkowski, V. Alcayne, J. Andrzejewski, D. Cano-Ott, A. Gawlik-Ramięga, E. Mendoza, A. Sánchez-Caballero, G. Sibbens, D. Vanleeuw, O. Aberle, S. Altieri, S. Amaducci, V. Babiano-Suarez, M. Bacak, J. Balibrea Correa, C. Beltrami, S. Bennett, A.P. Bernardes, E. Berthoumieux, R. Beyer, M. Boromiza, D. Bosnar, M. Caamaño, F. Calviño, M. Calviani, A. Casanovas, D.M. Castelluccio, F. Cerutti, G. Cescutti, S. Chasapoglou, E. Chiaveri, P. Colombetti, N. Colonna, P. Console Camprini, G. Cortés, M.A. Cortés-Giraldo, L. Cosentino, S. Cristallo, S. Dellmann, M. Di Castro, S. Di Maria, M. Diakaki, M. Dietz, C. Domingo-Pardo, R. Dressler, E. Dupont, I. Durán, Z. Eleme, S. Fargier, B. Fernández, B. Fernández-Domínguez, P. Finocchiaro, S. Fiore, V. Furman, F. García-Infantes, G. Gervino, S. Gilardoni, E. González-Romero, C. Guerrero, F. Gunsing, C. Gustavino, J. Heyse, W. Hillman, D.G. Jenkins, E. Jericha, A. Junghans, Y. Kadi, K. Kaperoni, G. Kaur, A. Kimura, I. Knapová, M. Kokkoris, Y. Kopatch, M. Krtička, N. Kyritsis, I. Ladarescu, C. Lederer-Woods, J. Lerendegui-Marco, G. Lerner, A. Manna, T. Martínez, A. Masi, C. Massimi, P. Mastinu, M. Mastromarco, E.A. Maugeri, A. Mazzone, A. Mengoni, V. Michalopoulou, P.M. Milazzo, R. Mucciola, F. Murtas, E. Musacchio-Gonzalez, A. Musumarra, A. Negret, A. Pérez de Rada Fiol, P. Pérez-Maroto, N. Patronis, J.A. Pavón-Rodríguez, M.G. Pellegriti, C. Petrone, E. Pirovano, J. Plaza del Olmo, S. Pomp, I. Porras, J. Praena, J.M. Quesada, R. Reifarth, D. Rochman, Y. Romanets, C. Rubbia, M. Sabaté-Gilarte, P. Schillebeeckx, D. Schumann, A. Sekhar, A.G. Smith, N.V. Sosnin, M.E. Stamati, A. Sturniolo, G. Tagliente, A. Tarifeño-Saldivia, D. Tarrío, P. Torres-Sánchez, E. Vagena, S. Valenta, V. Variale, P. Vaz, G. Vecchio, D. Vescovi, V. Vlachoudis, R. Vlastou, A. Wallner, P.J. Woods, T. Wright, R. Zarrella, P. Žugec., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A segmented total energy detector (sTED) optimized for (n, ¿) cross-section measurements at n_TOF EAR2

  • Alcayne Aicua, Víctor
  • Cano Ott, Daniel
  • García Alvarado, Jose Maria
  • González Romero, Enrique Miguel
  • Martínez, T.
  • Pérez de Rada Fiol, Alberto
  • Casanovas Hoste, Adrià
  • Calviño Tavares, Francisco
  • Cortés Rossell, Guillem Pere
  • Tarifeño Saldivia, Ariel Esteban
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron- induced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of ~ 4 · 107 neutrons per nominal proton pulse, which is ~50 times higher than the one of Experimental ARea 1 (EAR1) of ~ 8 · 105 neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detector’s response, by reducing the active volume per module and by using a photo-multiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to ¿-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at n_TOF EAR2., This work was supported in part by the I+D+i grant PGC2018- 096717-B-C21 funded by MCIN/AEI/10.13039/501100011033, by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552) and by funding agencies of the n_TOF participating institutions., Article signat per 136 autors/es: V. Alcayne, D. Cano-Ott, J. Garcia, E. González-Romero, T. Martínez, A. Pérez de Rada, J. Plaza, A. Sánchez-Caballero, J. Balibrea-Correa, C. Domingo-Pardo, J. Lerendegui-Marco, A. Casanovas, F. Calviño, O. Aberle, S. Altieri, S. Amaducci, J. Andrzejewski, V. Babiano-Suarez, M. Bacak, C. Beltrami, S. Bennett, A.P. Bernardes, E. Berthoumieux, R. Beyer , M. Boromiza, D. Bosnar, M. Caamaño, M. Calviani, D.M. Castelluccio, F. Cerutti, G. Cescutti, S. Chasapoglou, E. Chiaveri, P. Colombetti, N. Colonna, P. Console Camprini, G. Cortés, M.A. Cortés-Girald, L. Cosentino, S. Dellmann, M. Di Castro, S. Di Maria, M. Diakaki, M. Dietz, R. Dressler, E. Dupont, I. Durán, Z. Eleme, S. Fargier, B. Fernández, B. Fernández-Domínguez, P. Finocchiaro, S. Fiore, V. Furman, F. García-Infantes, A. Gawlik-Ramiega, G. Gervino, S. Gilardoni, C. Guerrero, F. Gunsing, C. Gustavino, J. Heyse, W. Hillman, D.G. Jenkins, E. Jericha, A. Junghans, Y. Kadi, K. Kaperoni, G. Kaur, A. Kimura, I. Knapová, M. Kokkoris, Y. Kopatch, M. Krtička, N. Kyritsis, I. Ladarescu, C. Lederer-Woods, G. Lerner, A. Manna, A. Masi, C. Massimi, P. Mastinu, M. Mastromarco, E.A. Maugeri, A. Mazzone, E. Mendoza, A. Mengoni, V. Michalopoulou, P.M. Milazzo, R. Mucciola, F. Murtas, E. Musacchio-Gonzalez, A. Musumarra, A. Negret, P. Pérez-Maroto, N. Patronis, J.A. Pavón-Rodríguez, M.G. Pellegriti, J. Perkowski, C. Petrone, L. Piersanti, E. Pirovano, S. Pomp, I. Porras, J. Praena, J.M. Quesada, R. Reifarth, D. Rochman, Y. Romanets, C. Rubbia, M. Sabaté-Gilarte, P. Schillebeeckx, D. Schumann, A. Sekhar, A.G. Smith, N.V. Sosnin, M. Spelta, M.E. Stamati, A. Sturniolo, G. Tagliente, A. Tarifeño-Saldivia, D. Tarrío, P. Torres-Sánchez, E. Vagena, S. Valenta, V. Variale, P. Vaz, G. Vecchio, D. Vescovi, V. Vlachoudis, R. Vlastou, A. Wallner, P.J. Woods, T. Wright, R. Zarrella, P. Žugec., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Measurement of the 244Cm neutron capture cross section at the n_TOF facility at CERN

  • Alcayne Aicua, Víctor
  • Kimura, Atsushi
  • Mendoza Cembranos, Emilio
  • Cano Ott, Daniel
  • Aberle, Oliver
  • Alvarez Velarde, Francisco
  • Calviño Tavares, Francisco
  • Casanovas Hoste, Adrià
  • Cortés Rossell, Guillem Pere
  • Tarifeño Saldivia, Ariel Esteban
Accurate neutron capture cross section data for minor actinides are essential for the safe and efficient management of high level radioactive waste produced during the operation of nuclear reactors. In particular, 244Cm, with a half-life of 18.11 years, dominates neutron emission in spent fuel and also contributes significantly to the decay heat and radiotoxicity. Furthermore, neutron capture on 244Cm opens the pathway for the formation of heavier isotopes such as Bk, Cf, and other Cm isotopes. Sensitivity studies for present and future nuclear reactors have highlighted the need to reduce the uncertainties in the 244Cm capture cross section. Experimental data on the capture cross section of this isotope are scarce due to the challenges associated with its measurements. Prior to the presented measurement and two recent measurements conducted at J-PARC, only one set of data for the 244Cm capture cross section existed, obtained in 1969 during an underground nuclear explosion experiment. The capture cross section of 244Cm has been measured at the n_TOF facility at CERN with three different experimental setups: one at Experimental Area 1 (EAR1) using the Total Absorption Calorimeter and two measurements at Experimental Area 2 (EAR2) with C D detectors, employing two different samples. The results from these three measurements were found to be compatible and then combined. In total, 17 resonances of 244Cm were measured at n_TOF below 300 eV. The radiative kernels obtained in this measurement are in good agreement with JENDL-4.0 for the majority of the resonances. Additionally, they are compatible with the recent JENDL-5 library below 50 eV, while at higher energies, the majority of radiative kernels from this evaluation based on the recent measurement by Kawase et al., are not compatible. Additionally, the 244Cm samples also contained 240Pu. Resonances of this isotope were analyzed in the energy range between 20 and 180 eV, and the results were found to be consistent with previous measurements and evaluations, that enhances confidence in the 244Cm results., This work was supported in part by the I+D+i grant PGC2018-096717-B-C21 funded by MCIN/AEI/10.13039/501100011033, by project PID2021-123100NB-I00 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE, by project PCI2022-135037-2 funded by MCIN/AEI/10.13039/501100011033/ and European Union NextGenerationEU/PRTR, by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552), Croatian Science Foundation project IP-2022-10-3878 and by funding agencies of the n_TOF participating institutions., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Low-uncertainty measurement of the 239Pu(n,f) cross section at n_TOF in a very broad energy range from 0.02 eV up to 10 MeV

  • Sánchez Caballero, Adrián
  • Cano Ott, Daniel
  • Mendoza Cembranos, Emilio
  • Alcayne Aicua, Víctor
  • Andrzejewski, Józef
  • Calviño Tavares, Francisco
  • Casanovas Hoste, Adrià
  • Cortés Rossell, Guillem Pere
  • Tarifeño Saldivia, Ariel Esteban
The 239Pu(n,f) cross section was measured with uncertainties below 4 % from 20 meV up to 10 MeV of neutron energy at CERN’s n_TOF facility using a novel fission fragment detector with a 185.59 m flight path. Measured cross section was normalized to 1059(6) eV¿·¿b in the 9–20 eV energy range, and is consistent within uncertainties with the standard thermal value and the IAEA reference 239Pu(n,f) cross section. Experimental key values include the integral ratio defined by Duran et al. 2024 and the spectrum averaged cross section in 252Cf(sf) reference neutron field of 1802(40) mb., In memory of Koen Vanaken, whose invaluable contributions and dedication to the Fuel Materials laboratories of SCK CEN will always be remembered. We wish to acknowledge André Moens (formerly member of the JRC-Geel Target Preparation laboratory, now retired) for his important contribution to the preparation of the 239Pu samples. Funding for this project was provided by the Euratom research and training program 2014–2018 under grant agreement no 847594 (ARIEL). Additional support came from the European Commission through the H2020 Framework Programme under grant agreement no 847552 (SANDA) and the project 36225/2/2021-1-RD-EUFRAT-GELINA (CHARPU), as well as from I+D+i grants PGC2018-096717-B-C21, PID2021-123100NB-I00, PID2022-142589OB-I00, and PDC2021-120828-I00 funded by MCIN/AEI/10.13039/501100011033. Furthermore, this research received partial funding from the National Science Centre in Poland (grant no UMO-2021/41/B/ST2/00326). The support of the funding agencies of all other participating institutes is also appreciated., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

miniBELEN: a modular neutron counter for (a, n) reactions

  • Mont i Geli, Nil
  • Tarifeño Saldivia, Ariel Esteban
  • Fraile, L. M.
  • Viñals Onsens, Silvia
  • Perea Martínez, Ángel
  • Pallàs i Solís, Max
  • Cortés Rossell, Guillem Pere
  • Nacher González, Enrique
  • Taín Enríquez, José Luis
  • Alcayne Aicua, Víctor
  • Algora Wesolowsk, Alejandro
  • Balibrea Correa, Javier
  • Benito García, Jaime
  • García Borge, María José
  • Calviño Tavares, Francisco
  • Blas del Hoyo, Alfredo de
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled in different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming to carry out measurements of (a, n) production yields, reaction cross-sections and neutron energy spectra. In this work we present and discuss several configurations of the miniBELEN detector. The experimental validation of the efficiency calculations using 252Cf sources and the measurement of the 27Al(a, n) 30P reaction is also presented., This work has been supported by the Spanish Ministerio de Economía y Competitividad under grants FPA2017-83946- C2-1 & C2-2 and PID2019-104714GB-C21 & C22, the Generalitat Valenciana Grant PROMETEO/2019/007, both cofounded by FEDER (EU), and the SANDA project funded under H2020-EURATOM-1.1 Grant No. 847552. The authors acknowledge the support from Centro de Microanálisis de Materiales (CMAM) - Universidad Autónoma de Madrid, for the beam time proposal (Comissioning of neutron detector systems for (a,݊n) reaction measurements) with code P01156, and its technical staff for their contribution to the operation of the accelerator., Article signat per 41 autors/es: N. Mont-Geli, A. Tarifeño-Saldivia, L.M. Fraile, S. Viñals, A. Perea, M. Pallàs, G. Cortés, E. Nácher, J.L. Tain, V. Alcayne, A. Algora, J. Balibrea-Correa, J. Benito, M.J.G. Borge, J.A. Briz, F. Calviño, D. Cano-Ott, A. De Blas, C. Domingo-Pardo, B. Fernández, R. Garcia, G. García, J. Gómez-Camacho, E.M. González-Romero, C. Guerrero, J. Lerendegui-Marco, M. Llanos, T. Martínez, E. Mendoza, J.R. Murias, S.E.A. Orrigo, A. Pérez de Rada, V. Pesudo, J. Plaza, J.M. Quesada, A. Sánchez, V. Sánchez-Tembleque, R. Santorelli, O. Tengblad, J.M. Udías and D. Villamarín., Postprint (published version)
Archivo Digital UPM
Publication Tesis doctoral (DoctoralThesis)

Methodologies for enhancing the neutronic assessment of Sodium-cooled Fast Reactors: from nuclear data to transient analysis

Archivo Digital UPM
Publication Contribución de congreso (ConferenceOutput)

WPEC/SG46 Exercise on Target Accuracy Requirement

  • Cabellos de Francisco, Oscar Luis|||0000-0002-2684-280X
  • Hursin, Mathieu|||0000-0002-1308-4464
  • Palmiotti, Pino
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

Sensitivity and uncertainty analyses for advanced nuclear systems (ALFRED, ASTRID, ESFR and MYRRHA)

  • Panizo, Sonia|||0000-0002-3642-3086
  • Alfonso, Ciro
  • Jiménez Carrascosa, Antonio|||0000-0001-6155-2034
  • García Herranz, Nuria|||0000-0002-0760-2974
  • Bécares Palacios, Vicente|||0000-0003-3434-9086
  • Romojaro, Pablo|||0000-0002-6343-1487
  • Álvarez Velarde, Francisco|||0000-0002-2050-0550
  • Cabellos de Francisco, Oscar Luis|||0000-0002-2684-280X
  • Cuesta Matesanz, Alejandro
  • Fiorito, Luca|||0000-0002-6091-3974
  • Stankovskiy, Alexey Yu
  • Van den Eynde, Gert|||0000-0002-4728-4456
Archivo Digital UPM
Publication Artículo científico (JournalArticle)

On the importance of target accuracy assessments and data assimilation for the co-development of nuclear data and fast reactors: MYRRHA and ESFR

  • Romojaro, Pablo|||0000-0002-6343-1487
  • Álvarez Velarde, Francisco|||0000-0002-2050-0550
  • Cabellos de Francisco, Oscar Luis|||0000-0002-2684-280X
  • García Herranz, Nuria|||0000-0002-0760-2974
  • Jiménez Carrascosa, Antonio|||0000-0001-6155-2034