Skip to main content

DATOS NUCLEARES PARA INVESTIGACION BASICA Y TECNOLOGIA NUCLEAR

PGC2018-096717-B-C21

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Generación de Conocimiento y Fortalecimiento Científico y Tecnológico del Sistema de I+D+i
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D (Excelencia / Generación de Conocimiento)
Call year 2018
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre CENTRO DE INVESTIGACION ENERGETICA MEDIOAMBIENTAL Y TECNOLOGICA (CIEMAT)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Thermal neutron background at Laboratorio Subterráneo de Canfranc (LSC)

  • Plaza del Olmo, J.
  • Martínez, T.
  • Bécares, V.
  • Cano-Ott, D.
  • Villamarin, D.
  • Pérez de Rada, A.
  • Mendoza, E.
  • Pesudo, V.
  • Santorelli, R.
  • Peña-Garay, Carlos
  • Balibrea, Javier
  • Boeltzig, A.
The thermal neutron background at Laboratorio Subterráneo de Canfranc (LSC) has been determined using several He proportional counter detectors. Bare and Cd shielded counters were used in a series of long measurements. Pulse shape discrimination techniques were applied to discriminate between neutron and gamma signals as well as other intrinsic contributions. Montecarlo simulations allowed us to estimate the sensitivity of the detectors and calculate values for the background flux of thermal neutrons inside Hall-A of LSC. The obtained value is (3.5±0.8)×10 n/cms, and is within an order of magnitude compared to similar facilities., This work was supported partially by the Spanish Ministerio de Ciencia e Innovación and its Plan Nacional de I+D+i de Física de Partículas projects: FPA2016-76765-P and FPA2018-096717-B-C21. The authors want to acknowledge the help provided by the staff at LSC in the preparation and support for this work., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Neutron capture measurements with high efficiency detectors and the Pulse Height Weighting Technique

  • Mendoza, E.
  • Alcayne, V.
  • Cano-Ott, D.
  • González-Romero, E.
  • Martínez, T.
  • Pérez de Rada, A.
  • Sánchez-Caballero, A.
  • Balibrea, Javier
  • Domingo Pardo, César
  • Lerendegui-Marco, J.
  • Calviño, F.
  • Guerrero, C.
Neutron capture cross section measurements in time-of-flight facilities are usually performed by detecting the prompt γ-rays emitted in the capture reactions. One of the difficulties to be addressed in these measurements is that the emitted γ-rays may change with the neutron energy, and therefore also the detection efficiency. To deal with this situation, many measurements use the so called Total Energy Detection (TED) technique, usually in combination with the Pulse Height Weighting Technique (PHWT). With it, it is sought that the detection efficiency depends only on the total energy of the γ-ray cascade, which does not vary much with the neutron energy. This technique was developed in the 1960s and has been used in many neutron capture experiments to date. One of the requirements of the technique is that γ-ray detectors have a low efficiency. This has meant that the PHWT has been used with experimental setups with low detection efficiencies. However, this condition does not have to be fulfilled by the experimental system as a whole. The main goal of this work is to show that it is possible to measure with a high efficiency detection system that uses the PHWT, and how to analyze the measured data., This work was supported in part by the I+D+i grant PGC2018- 096717-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

The DESPEC setup for GSI and FAIR

  • Mistry, A.K.
  • Tain, José Luis
  • Agramunt, Jorge
  • Algora, Alejandro
  • Guadilla, V.
  • Morales, A. I.
  • Nácher, Enrique
  • Orrigo, S. E. A.
  • Rubio, Berta
The DEcay SPECtroscopy (DESPEC) setup for nuclear structure investigations was developed and commissioned at GSI, Germany in preparation for a full campaign of experiments at the FRS and Super-FRS. In this paper, we report on the first employment of the setup in the hybrid configuration with the AIDA implanter coupled to the FATIMA LaBr(Ce) fast-timing array, and high-purity germanium detectors. Initial results are shown from the first experiments carried out with the setup. An overview of the setup and function is discussed, including technical advancements along the path.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

CLYC as a neutron detector in low background conditions

  • Plaza del Olmo, J.
  • Bécares, V.
  • Cano-Ott, D.
  • Gómez, C.
  • Martínez, T.
  • Mendoza, E.
  • de Rada, A.P.
  • Pesudo, V.
  • Sáez Vergara, José Carlos
  • Santorelli, R.
  • Villamarin, D.
  • Ianni, Aldo
  • Peña-Garay, Carlos
  • Balibrea, Javier
  • Boeltzig, A.
  • Imbriani, G.
We report on the thermal neutron flux measurements carried out at the Laboratorio Subterráneo de Canfranc (LSC) with two commercial 2 × 2 CLYC detectors. The measurements were performed as part of an experimental campaign at LSC with He detectors, for establishing the sensitivity limits and use of CLYCs in low background conditions. A careful characterization of the intrinsic α and γ -ray background in the detectors was required and done with dedicated measurements. It was found that the α activities in the two CLYC crystals differ by a factor of three, and the use of Monte Carlo simulations and a Bayesian unfolding method allowed us to determine the specific α activities from the U and Th decay chains. The simulations and unfolding also revealed that the γ -ray background registered in the detectors is dominated by the intrinsic activity of the components of the detector such as the aluminum housing and photo-multiplier and that the activity within the crystal is low in comparison. The data from the neutron flux measurements with the two detectors were analyzed with different methodologies: one based on an innovative α /neutron pulse shape discrimination method and one based on the subtraction of the intrinsic α background that masks the neutron signals in the region of interest. The neutron sensitivity of the CLYCs was calculated by Monte Carlo simulations with MCNP6 and GEANT4. The resulting thermal neutron fluxes are in good agreement with complementary flux measurement performed with He detectors, but close to the detection limit imposed by the intrinsic α activity.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Neutron capture measurements for s-process nucleosynthesis: A review about CERN n_TOF developments and contributions

  • n_TOF Collaboration
  • Babiano-Suárez, V.
  • Balibrea, Javier
  • Fuente-Rosales, G. de la
  • Lerendegui-Marco, J.
  • Domingo Pardo, César
  • Tarifeño-Saldivia, A.
  • Torres-Sánchez, Pablo
This article presents a review about the main CERN n_TOF contributions to the field of neutron-capture experiments of interest for s-process nucleosynthesis studies over the last 25 years, with a special focus on the measurement of radioactive isotopes. A few recent capture experiments on stable isotopes of astrophysical interest are also discussed. Results on s-process branching nuclei are appropriate to illustrate how advances in detection systems and upgrades in the facility have enabled increasingly challenging experiments and, as a consequence, have led to a better understanding and modeling of the s-process mechanism of nucleosynthesis. New endeavors combining radioactive-ion beams from ISOLDE for the production of radioisotopically pure samples for activation experiments at the new NEAR facility at n_TOF are briefly discussed. On the basis of these new exciting results, also current limitations of state-of-the-art TOF and activation techniques will be depicted, thereby showing the pressing need for further upgrades and enhancements on both facilities and detection systems. A brief account of the potential technique based on inverse kinematics for direct neutron-capture measurements is also presented., The authors acknowledge support from all the funding agencies of participating institutions. Part of this work was supported by the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (ERC-COG Nr. 681740 and ERC-STG Nr.677497), European H2020-847552 (SANDA), the MCIN/AEI 10.13039/501100011033 under grants Severo Ochoa CEX2023-001292-S, PID2022-138297NB-C21, PID2019-104714GB-C21, FPA2017-83946-C2-1-P, FIS2015-71688-ERC, FPA2016-77689-C2-1-R, RTI2018-098117-B-C21, PGC2018-096717-B-C21, PID2021-123100NB-I00 funded by MCIN/AEI 10.13039/501100011033/FEDER, UE, PCI2022-135037-2 funded by MCIN/AEI 10.13039/501100011033 and EU-NextGenerationEU/PRTR. The corresponding author has applied a Creative Commons Attribution (CC BY-NC-ND 4.0) license., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Multi-section fission ionization chamber for measurement of 239 Pu (n, y) reaction in fission tagging method

  • Perkowski, Jaroslaw
  • Alcayne Aicua, Víctor
  • Andrzejewski, Józef
  • Cano Ott, Daniel
  • Gawlik Ramiega, Aleksandra
  • Mendoza, Emilio
  • Sánchez Caballero, Adrián
  • Sibbens, Geodele
  • Vanleeuw, David
  • Aberle, Oliver
  • Altieri, Saverio
  • Amaducci, Simone
  • Babiano Suárez, Víctor
  • Bacak, Michael
  • Balibrea Correa, Javier
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
The 239 Pu (n, y) reaction cross section is very important for operation of both thermal and fast reactors, when loaded with MOX fuels. According to the NEA/OECD High Priority Request List the precision of cross section data for this reaction should be improved. The cross section of (n, f) reaction is much higher compared to (n, y) for this isotope. In such conditions the fission tagging technique could be applied to identify the fission background. In the past, this technique was successfully used for capture measurements at the n_TOF facility at CERN. The multi-section fission ionization chamber was constructed and used in the combination with Total Absorption Calorimeter (TAC) for detecting gamma rays for the precise measurement of 239 Pu (n, y) reaction cross section at the n_TOF facility., We acknowledge support of Narodowe Centrum Nauki (NCN), Poland (Grant No. UMO-2021/41/B/ST2/00326) and UE in the frame of the SANDA grant nr 847552 (Horizon 2020 project) and project of Ministry of Science and Higher Education of Poland nr 450734/PnH 2/2019 and Projekt Miedzynarodowy Wspolfinansowany Nr W93/H2019/Euratom/2019 (5099/H2020-Euratom/2020/2) and also University of Lodz under the grant (9/IDUB/MLOD/2021). This work was partially supported by PGC2018-096717- B-C21, and PID2022- 142589OB-I00 funded by MCIN/AEI/10.13039/501100011033 and also by Croatian Science Foundation project IP-2022-10-3878. The experimental data used in this research were generated through ac- cess to the GELINA facility under the Framework for access to the Joint Research Centre physical Research Infrastructures of the Euro- pean Commission (CHARPU project, Research Infrastructure Access Agreement N◦ 36225/2/2021-1-RD-EUFRAT-GELINA)., Article signat per 136 autors/es: J. Perkowski, V. Alcayne, J. Andrzejewski, D. Cano-Ott, A. Gawlik-Ramięga, E. Mendoza, A. Sánchez-Caballero, G. Sibbens, D. Vanleeuw, O. Aberle, S. Altieri, S. Amaducci, V. Babiano-Suarez, M. Bacak, J. Balibrea Correa, C. Beltrami, S. Bennett, A.P. Bernardes, E. Berthoumieux, R. Beyer, M. Boromiza, D. Bosnar, M. Caamaño, F. Calviño, M. Calviani, A. Casanovas, D.M. Castelluccio, F. Cerutti, G. Cescutti, S. Chasapoglou, E. Chiaveri, P. Colombetti, N. Colonna, P. Console Camprini, G. Cortés, M.A. Cortés-Giraldo, L. Cosentino, S. Cristallo, S. Dellmann, M. Di Castro, S. Di Maria, M. Diakaki, M. Dietz, C. Domingo-Pardo, R. Dressler, E. Dupont, I. Durán, Z. Eleme, S. Fargier, B. Fernández, B. Fernández-Domínguez, P. Finocchiaro, S. Fiore, V. Furman, F. García-Infantes, G. Gervino, S. Gilardoni, E. González-Romero, C. Guerrero, F. Gunsing, C. Gustavino, J. Heyse, W. Hillman, D.G. Jenkins, E. Jericha, A. Junghans, Y. Kadi, K. Kaperoni, G. Kaur, A. Kimura, I. Knapová, M. Kokkoris, Y. Kopatch, M. Krtička, N. Kyritsis, I. Ladarescu, C. Lederer-Woods, J. Lerendegui-Marco, G. Lerner, A. Manna, T. Martínez, A. Masi, C. Massimi, P. Mastinu, M. Mastromarco, E.A. Maugeri, A. Mazzone, A. Mengoni, V. Michalopoulou, P.M. Milazzo, R. Mucciola, F. Murtas, E. Musacchio-Gonzalez, A. Musumarra, A. Negret, A. Pérez de Rada Fiol, P. Pérez-Maroto, N. Patronis, J.A. Pavón-Rodríguez, M.G. Pellegriti, C. Petrone, E. Pirovano, J. Plaza del Olmo, S. Pomp, I. Porras, J. Praena, J.M. Quesada, R. Reifarth, D. Rochman, Y. Romanets, C. Rubbia, M. Sabaté-Gilarte, P. Schillebeeckx, D. Schumann, A. Sekhar, A.G. Smith, N.V. Sosnin, M.E. Stamati, A. Sturniolo, G. Tagliente, A. Tarifeño-Saldivia, D. Tarrío, P. Torres-Sánchez, E. Vagena, S. Valenta, V. Variale, P. Vaz, G. Vecchio, D. Vescovi, V. Vlachoudis, R. Vlastou, A. Wallner, P.J. Woods, T. Wright, R. Zarrella, P. Žugec.
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Measurement of the 244Cm neutron capture cross section at the n_TOF facility at CERN

  • Alcayne Aicua, Víctor
  • Kimura, Atsushi
  • Mendoza Cembranos, Emilio
  • Cano Ott, Daniel
  • Aberle, Oliver
  • Alvarez Velarde, Francisco
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
Accurate neutron capture cross section data for minor actinides are essential for the safe and efficient management of high level radioactive waste produced during the operation of nuclear reactors. In particular, 244Cm, with a half-life of 18.11 years, dominates neutron emission in spent fuel and also contributes significantly to the decay heat and radiotoxicity. Furthermore, neutron capture on 244Cm opens the pathway for the formation of heavier isotopes such as Bk, Cf, and other Cm isotopes. Sensitivity studies for present and future nuclear reactors have highlighted the need to reduce the uncertainties in the 244Cm capture cross section. Experimental data on the capture cross section of this isotope are scarce due to the challenges associated with its measurements. Prior to the presented measurement and two recent measurements conducted at J-PARC, only one set of data for the 244Cm capture cross section existed, obtained in 1969 during an underground nuclear explosion experiment. The capture cross section of 244Cm has been measured at the n_TOF facility at CERN with three different experimental setups: one at Experimental Area 1 (EAR1) using the Total Absorption Calorimeter and two measurements at Experimental Area 2 (EAR2) with C D detectors, employing two different samples. The results from these three measurements were found to be compatible and then combined. In total, 17 resonances of 244Cm were measured at n_TOF below 300 eV. The radiative kernels obtained in this measurement are in good agreement with JENDL-4.0 for the majority of the resonances. Additionally, they are compatible with the recent JENDL-5 library below 50 eV, while at higher energies, the majority of radiative kernels from this evaluation based on the recent measurement by Kawase et al., are not compatible. Additionally, the 244Cm samples also contained 240Pu. Resonances of this isotope were analyzed in the energy range between 20 and 180 eV, and the results were found to be consistent with previous measurements and evaluations, that enhances confidence in the 244Cm results., This work was supported in part by the I+D+i grant PGC2018-096717-B-C21 funded by MCIN/AEI/10.13039/501100011033, by project PID2021-123100NB-I00 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE, by project PCI2022-135037-2 funded by MCIN/AEI/10.13039/501100011033/ and European Union NextGenerationEU/PRTR, by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552), Croatian Science Foundation project IP-2022-10-3878 and by funding agencies of the n_TOF participating institutions., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Low-uncertainty measurement of the 239Pu(n,f) cross section at n_TOF in a very broad energy range from 0.02 eV up to 10 MeV

  • Sánchez Caballero, Adrián
  • Cano Ott, Daniel
  • Mendoza Cembranos, Emilio
  • Alcayne Aicua, Víctor
  • Andrzejewski, Józef
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
The 239Pu(n,f) cross section was measured with uncertainties below 4 % from 20 meV up to 10 MeV of neutron energy at CERN’s n_TOF facility using a novel fission fragment detector with a 185.59 m flight path. Measured cross section was normalized to 1059(6) eV¿·¿b in the 9–20 eV energy range, and is consistent within uncertainties with the standard thermal value and the IAEA reference 239Pu(n,f) cross section. Experimental key values include the integral ratio defined by Duran et al. 2024 and the spectrum averaged cross section in 252Cf(sf) reference neutron field of 1802(40) mb., In memory of Koen Vanaken, whose invaluable contributions and dedication to the Fuel Materials laboratories of SCK CEN will always be remembered. We wish to acknowledge André Moens (formerly member of the JRC-Geel Target Preparation laboratory, now retired) for his important contribution to the preparation of the 239Pu samples. Funding for this project was provided by the Euratom research and training program 2014–2018 under grant agreement no 847594 (ARIEL). Additional support came from the European Commission through the H2020 Framework Programme under grant agreement no 847552 (SANDA) and the project 36225/2/2021-1-RD-EUFRAT-GELINA (CHARPU), as well as from I+D+i grants PGC2018-096717-B-C21, PID2021-123100NB-I00, PID2022-142589OB-I00, and PDC2021-120828-I00 funded by MCIN/AEI/10.13039/501100011033. Furthermore, this research received partial funding from the National Science Centre in Poland (grant no UMO-2021/41/B/ST2/00326). The support of the funding agencies of all other participating institutes is also appreciated., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A segmented total energy detector (sTED) optimized for (n, ¿) cross-section measurements at n_TOF EAR2

  • Alcayne Aicua, Víctor
  • Cano Ott, Daniel
  • García Alvarado, Jose Maria
  • González Romero, Enrique Miguel
  • Martínez, T.
  • Pérez de Rada Fiol, Alberto
  • Casanovas Hoste, Adrià|||0000-0002-7138-0894
  • Calviño Tavares, Francisco|||0000-0002-7198-4639
  • Cortés Rossell, Guillem Pere|||0000-0002-3648-5826
  • Tarifeño Saldivia, Ariel Esteban|||0000-0001-8552-5030
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron- induced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of ~ 4 · 107 neutrons per nominal proton pulse, which is ~50 times higher than the one of Experimental ARea 1 (EAR1) of ~ 8 · 105 neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detector’s response, by reducing the active volume per module and by using a photo-multiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to ¿-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at n_TOF EAR2., This work was supported in part by the I+D+i grant PGC2018- 096717-B-C21 funded by MCIN/AEI/10.13039/501100011033, by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552) and by funding agencies of the n_TOF participating institutions., Article signat per 136 autors/es: V. Alcayne, D. Cano-Ott, J. Garcia, E. González-Romero, T. Martínez, A. Pérez de Rada, J. Plaza, A. Sánchez-Caballero, J. Balibrea-Correa, C. Domingo-Pardo, J. Lerendegui-Marco, A. Casanovas, F. Calviño, O. Aberle, S. Altieri, S. Amaducci, J. Andrzejewski, V. Babiano-Suarez, M. Bacak, C. Beltrami, S. Bennett, A.P. Bernardes, E. Berthoumieux, R. Beyer , M. Boromiza, D. Bosnar, M. Caamaño, M. Calviani, D.M. Castelluccio, F. Cerutti, G. Cescutti, S. Chasapoglou, E. Chiaveri, P. Colombetti, N. Colonna, P. Console Camprini, G. Cortés, M.A. Cortés-Girald, L. Cosentino, S. Dellmann, M. Di Castro, S. Di Maria, M. Diakaki, M. Dietz, R. Dressler, E. Dupont, I. Durán, Z. Eleme, S. Fargier, B. Fernández, B. Fernández-Domínguez, P. Finocchiaro, S. Fiore, V. Furman, F. García-Infantes, A. Gawlik-Ramiega, G. Gervino, S. Gilardoni, C. Guerrero, F. Gunsing, C. Gustavino, J. Heyse, W. Hillman, D.G. Jenkins, E. Jericha, A. Junghans, Y. Kadi, K. Kaperoni, G. Kaur, A. Kimura, I. Knapová, M. Kokkoris, Y. Kopatch, M. Krtička, N. Kyritsis, I. Ladarescu, C. Lederer-Woods, G. Lerner, A. Manna, A. Masi, C. Massimi, P. Mastinu, M. Mastromarco, E.A. Maugeri, A. Mazzone, E. Mendoza, A. Mengoni, V. Michalopoulou, P.M. Milazzo, R. Mucciola, F. Murtas, E. Musacchio-Gonzalez, A. Musumarra, A. Negret, P. Pérez-Maroto, N. Patronis, J.A. Pavón-Rodríguez, M.G. Pellegriti, J. Perkowski, C. Petrone, L. Piersanti, E. Pirovano, S. Pomp, I. Porras, J. Praena, J.M. Quesada, R. Reifarth, D. Rochman, Y. Romanets, C. Rubbia, M. Sabaté-Gilarte, P. Schillebeeckx, D. Schumann, A. Sekhar, A.G. Smith, N.V. Sosnin, M. Spelta, M.E. Stamati, A. Sturniolo, G. Tagliente, A. Tarifeño-Saldivia, D. Tarrío, P. Torres-Sánchez, E. Vagena, S. Valenta, V. Variale, P. Vaz, G. Vecchio, D. Vescovi, V. Vlachoudis, R. Vlastou, A. Wallner, P.J. Woods, T. Wright, R. Zarrella, P. Žugec.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Multi-section fission ionization chamber for measurement of 239 Pu (n, y) reaction in fission tagging method

  • Perkowski, Jaroslaw
  • Alcayne Aicua, Víctor
  • Andrzejewski, Józef
  • Cano Ott, Daniel
  • Gawlik Ramiega, Aleksandra
  • Mendoza, Emilio
  • Sánchez Caballero, Adrián
  • Sibbens, Geodele
  • Vanleeuw, David
  • Aberle, Oliver
  • Altieri, Saverio
  • Amaducci, Simone
  • Babiano Suárez, Víctor
  • Bacak, Michael
  • Balibrea Correa, Javier
  • Calviño Tavares, Francisco
  • Casanovas Hoste, Adrià
  • Cortés Rossell, Guillem Pere
  • Tarifeño Saldivia, Ariel Esteban
The 239 Pu (n, y) reaction cross section is very important for operation of both thermal and fast reactors, when loaded with MOX fuels. According to the NEA/OECD High Priority Request List the precision of cross section data for this reaction should be improved. The cross section of (n, f) reaction is much higher compared to (n, y) for this isotope. In such conditions the fission tagging technique could be applied to identify the fission background. In the past, this technique was successfully used for capture measurements at the n_TOF facility at CERN. The multi-section fission ionization chamber was constructed and used in the combination with Total Absorption Calorimeter (TAC) for detecting gamma rays for the precise measurement of 239 Pu (n, y) reaction cross section at the n_TOF facility., We acknowledge support of Narodowe Centrum Nauki (NCN), Poland (Grant No. UMO-2021/41/B/ST2/00326) and UE in the frame of the SANDA grant nr 847552 (Horizon 2020 project) and project of Ministry of Science and Higher Education of Poland nr 450734/PnH 2/2019 and Projekt Miedzynarodowy Wspolfinansowany Nr W93/H2019/Euratom/2019 (5099/H2020-Euratom/2020/2) and also University of Lodz under the grant (9/IDUB/MLOD/2021). This work was partially supported by PGC2018-096717- B-C21, and PID2022- 142589OB-I00 funded by MCIN/AEI/10.13039/501100011033 and also by Croatian Science Foundation project IP-2022-10-3878. The experimental data used in this research were generated through ac- cess to the GELINA facility under the Framework for access to the Joint Research Centre physical Research Infrastructures of the Euro- pean Commission (CHARPU project, Research Infrastructure Access Agreement N◦ 36225/2/2021-1-RD-EUFRAT-GELINA)., Article signat per 136 autors/es: J. Perkowski, V. Alcayne, J. Andrzejewski, D. Cano-Ott, A. Gawlik-Ramięga, E. Mendoza, A. Sánchez-Caballero, G. Sibbens, D. Vanleeuw, O. Aberle, S. Altieri, S. Amaducci, V. Babiano-Suarez, M. Bacak, J. Balibrea Correa, C. Beltrami, S. Bennett, A.P. Bernardes, E. Berthoumieux, R. Beyer, M. Boromiza, D. Bosnar, M. Caamaño, F. Calviño, M. Calviani, A. Casanovas, D.M. Castelluccio, F. Cerutti, G. Cescutti, S. Chasapoglou, E. Chiaveri, P. Colombetti, N. Colonna, P. Console Camprini, G. Cortés, M.A. Cortés-Giraldo, L. Cosentino, S. Cristallo, S. Dellmann, M. Di Castro, S. Di Maria, M. Diakaki, M. Dietz, C. Domingo-Pardo, R. Dressler, E. Dupont, I. Durán, Z. Eleme, S. Fargier, B. Fernández, B. Fernández-Domínguez, P. Finocchiaro, S. Fiore, V. Furman, F. García-Infantes, G. Gervino, S. Gilardoni, E. González-Romero, C. Guerrero, F. Gunsing, C. Gustavino, J. Heyse, W. Hillman, D.G. Jenkins, E. Jericha, A. Junghans, Y. Kadi, K. Kaperoni, G. Kaur, A. Kimura, I. Knapová, M. Kokkoris, Y. Kopatch, M. Krtička, N. Kyritsis, I. Ladarescu, C. Lederer-Woods, J. Lerendegui-Marco, G. Lerner, A. Manna, T. Martínez, A. Masi, C. Massimi, P. Mastinu, M. Mastromarco, E.A. Maugeri, A. Mazzone, A. Mengoni, V. Michalopoulou, P.M. Milazzo, R. Mucciola, F. Murtas, E. Musacchio-Gonzalez, A. Musumarra, A. Negret, A. Pérez de Rada Fiol, P. Pérez-Maroto, N. Patronis, J.A. Pavón-Rodríguez, M.G. Pellegriti, C. Petrone, E. Pirovano, J. Plaza del Olmo, S. Pomp, I. Porras, J. Praena, J.M. Quesada, R. Reifarth, D. Rochman, Y. Romanets, C. Rubbia, M. Sabaté-Gilarte, P. Schillebeeckx, D. Schumann, A. Sekhar, A.G. Smith, N.V. Sosnin, M.E. Stamati, A. Sturniolo, G. Tagliente, A. Tarifeño-Saldivia, D. Tarrío, P. Torres-Sánchez, E. Vagena, S. Valenta, V. Variale, P. Vaz, G. Vecchio, D. Vescovi, V. Vlachoudis, R. Vlastou, A. Wallner, P.J. Woods, T. Wright, R. Zarrella, P. Žugec., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A segmented total energy detector (sTED) optimized for (n, ¿) cross-section measurements at n_TOF EAR2

  • Alcayne Aicua, Víctor
  • Cano Ott, Daniel
  • García Alvarado, Jose Maria
  • González Romero, Enrique Miguel
  • Martínez, T.
  • Pérez de Rada Fiol, Alberto
  • Casanovas Hoste, Adrià
  • Calviño Tavares, Francisco
  • Cortés Rossell, Guillem Pere
  • Tarifeño Saldivia, Ariel Esteban
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron- induced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of ~ 4 · 107 neutrons per nominal proton pulse, which is ~50 times higher than the one of Experimental ARea 1 (EAR1) of ~ 8 · 105 neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detector’s response, by reducing the active volume per module and by using a photo-multiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to ¿-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at n_TOF EAR2., This work was supported in part by the I+D+i grant PGC2018- 096717-B-C21 funded by MCIN/AEI/10.13039/501100011033, by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552) and by funding agencies of the n_TOF participating institutions., Article signat per 136 autors/es: V. Alcayne, D. Cano-Ott, J. Garcia, E. González-Romero, T. Martínez, A. Pérez de Rada, J. Plaza, A. Sánchez-Caballero, J. Balibrea-Correa, C. Domingo-Pardo, J. Lerendegui-Marco, A. Casanovas, F. Calviño, O. Aberle, S. Altieri, S. Amaducci, J. Andrzejewski, V. Babiano-Suarez, M. Bacak, C. Beltrami, S. Bennett, A.P. Bernardes, E. Berthoumieux, R. Beyer , M. Boromiza, D. Bosnar, M. Caamaño, M. Calviani, D.M. Castelluccio, F. Cerutti, G. Cescutti, S. Chasapoglou, E. Chiaveri, P. Colombetti, N. Colonna, P. Console Camprini, G. Cortés, M.A. Cortés-Girald, L. Cosentino, S. Dellmann, M. Di Castro, S. Di Maria, M. Diakaki, M. Dietz, R. Dressler, E. Dupont, I. Durán, Z. Eleme, S. Fargier, B. Fernández, B. Fernández-Domínguez, P. Finocchiaro, S. Fiore, V. Furman, F. García-Infantes, A. Gawlik-Ramiega, G. Gervino, S. Gilardoni, C. Guerrero, F. Gunsing, C. Gustavino, J. Heyse, W. Hillman, D.G. Jenkins, E. Jericha, A. Junghans, Y. Kadi, K. Kaperoni, G. Kaur, A. Kimura, I. Knapová, M. Kokkoris, Y. Kopatch, M. Krtička, N. Kyritsis, I. Ladarescu, C. Lederer-Woods, G. Lerner, A. Manna, A. Masi, C. Massimi, P. Mastinu, M. Mastromarco, E.A. Maugeri, A. Mazzone, E. Mendoza, A. Mengoni, V. Michalopoulou, P.M. Milazzo, R. Mucciola, F. Murtas, E. Musacchio-Gonzalez, A. Musumarra, A. Negret, P. Pérez-Maroto, N. Patronis, J.A. Pavón-Rodríguez, M.G. Pellegriti, J. Perkowski, C. Petrone, L. Piersanti, E. Pirovano, S. Pomp, I. Porras, J. Praena, J.M. Quesada, R. Reifarth, D. Rochman, Y. Romanets, C. Rubbia, M. Sabaté-Gilarte, P. Schillebeeckx, D. Schumann, A. Sekhar, A.G. Smith, N.V. Sosnin, M. Spelta, M.E. Stamati, A. Sturniolo, G. Tagliente, A. Tarifeño-Saldivia, D. Tarrío, P. Torres-Sánchez, E. Vagena, S. Valenta, V. Variale, P. Vaz, G. Vecchio, D. Vescovi, V. Vlachoudis, R. Vlastou, A. Wallner, P.J. Woods, T. Wright, R. Zarrella, P. Žugec., Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Measurement of the 244Cm neutron capture cross section at the n_TOF facility at CERN

  • Alcayne Aicua, Víctor
  • Kimura, Atsushi
  • Mendoza Cembranos, Emilio
  • Cano Ott, Daniel
  • Aberle, Oliver
  • Alvarez Velarde, Francisco
  • Calviño Tavares, Francisco
  • Casanovas Hoste, Adrià
  • Cortés Rossell, Guillem Pere
  • Tarifeño Saldivia, Ariel Esteban
Accurate neutron capture cross section data for minor actinides are essential for the safe and efficient management of high level radioactive waste produced during the operation of nuclear reactors. In particular, 244Cm, with a half-life of 18.11 years, dominates neutron emission in spent fuel and also contributes significantly to the decay heat and radiotoxicity. Furthermore, neutron capture on 244Cm opens the pathway for the formation of heavier isotopes such as Bk, Cf, and other Cm isotopes. Sensitivity studies for present and future nuclear reactors have highlighted the need to reduce the uncertainties in the 244Cm capture cross section. Experimental data on the capture cross section of this isotope are scarce due to the challenges associated with its measurements. Prior to the presented measurement and two recent measurements conducted at J-PARC, only one set of data for the 244Cm capture cross section existed, obtained in 1969 during an underground nuclear explosion experiment. The capture cross section of 244Cm has been measured at the n_TOF facility at CERN with three different experimental setups: one at Experimental Area 1 (EAR1) using the Total Absorption Calorimeter and two measurements at Experimental Area 2 (EAR2) with C D detectors, employing two different samples. The results from these three measurements were found to be compatible and then combined. In total, 17 resonances of 244Cm were measured at n_TOF below 300 eV. The radiative kernels obtained in this measurement are in good agreement with JENDL-4.0 for the majority of the resonances. Additionally, they are compatible with the recent JENDL-5 library below 50 eV, while at higher energies, the majority of radiative kernels from this evaluation based on the recent measurement by Kawase et al., are not compatible. Additionally, the 244Cm samples also contained 240Pu. Resonances of this isotope were analyzed in the energy range between 20 and 180 eV, and the results were found to be consistent with previous measurements and evaluations, that enhances confidence in the 244Cm results., This work was supported in part by the I+D+i grant PGC2018-096717-B-C21 funded by MCIN/AEI/10.13039/501100011033, by project PID2021-123100NB-I00 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE, by project PCI2022-135037-2 funded by MCIN/AEI/10.13039/501100011033/ and European Union NextGenerationEU/PRTR, by the European Commission H2020 Framework Programme project SANDA (Grant agreement ID: 847552), Croatian Science Foundation project IP-2022-10-3878 and by funding agencies of the n_TOF participating institutions., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Low-uncertainty measurement of the 239Pu(n,f) cross section at n_TOF in a very broad energy range from 0.02 eV up to 10 MeV

  • Sánchez Caballero, Adrián
  • Cano Ott, Daniel
  • Mendoza Cembranos, Emilio
  • Alcayne Aicua, Víctor
  • Andrzejewski, Józef
  • Calviño Tavares, Francisco
  • Casanovas Hoste, Adrià
  • Cortés Rossell, Guillem Pere
  • Tarifeño Saldivia, Ariel Esteban
The 239Pu(n,f) cross section was measured with uncertainties below 4 % from 20 meV up to 10 MeV of neutron energy at CERN’s n_TOF facility using a novel fission fragment detector with a 185.59 m flight path. Measured cross section was normalized to 1059(6) eV¿·¿b in the 9–20 eV energy range, and is consistent within uncertainties with the standard thermal value and the IAEA reference 239Pu(n,f) cross section. Experimental key values include the integral ratio defined by Duran et al. 2024 and the spectrum averaged cross section in 252Cf(sf) reference neutron field of 1802(40) mb., In memory of Koen Vanaken, whose invaluable contributions and dedication to the Fuel Materials laboratories of SCK CEN will always be remembered. We wish to acknowledge André Moens (formerly member of the JRC-Geel Target Preparation laboratory, now retired) for his important contribution to the preparation of the 239Pu samples. Funding for this project was provided by the Euratom research and training program 2014–2018 under grant agreement no 847594 (ARIEL). Additional support came from the European Commission through the H2020 Framework Programme under grant agreement no 847552 (SANDA) and the project 36225/2/2021-1-RD-EUFRAT-GELINA (CHARPU), as well as from I+D+i grants PGC2018-096717-B-C21, PID2021-123100NB-I00, PID2022-142589OB-I00, and PDC2021-120828-I00 funded by MCIN/AEI/10.13039/501100011033. Furthermore, this research received partial funding from the National Science Centre in Poland (grant no UMO-2021/41/B/ST2/00326). The support of the funding agencies of all other participating institutes is also appreciated., Peer Reviewed, Postprint (published version)