Skip to main content

DESARROLLO DE UNA HERRAMIENTA COMPUTACIONAL DE INTERACCION FLUIDO-SOLIDO EN EL AMBITO CARDIOVASCULAR. APLICACION AL DISEÑO DE UN NUEVO PROTOTIPO DE FILTRO ANTITROMBO

BES-2011-043471

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Nacional de Formación de Recursos Humanos de Investigación
Subprogram subprograma de Formación de Personal Investigador (FPI)
Call Contratos Predoctorales
Call year 2011
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Subdirección General de Formación e Incorporación de Investigadores
Beneficiary centre UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Numerical and experimental study of the fluid flow through a medical device

  • Nicolás, M.
  • Palero, V.R.
  • Peña, E.
  • Arroyo, M.P.
  • Martínez, M.A.
  • Malvè, M.
The purpose of this paper is to verify a commercial software based fluid–structure interaction scheme for the inferior vena cava. Vena cava deep thrombosis (TVP) is a potentially deathly disease consequent to pulmonary thromboembolism (TEP). TEP consist in the obstruction of the pulmonary artery due to a blood clot traveling in the cardiovascular system and is treated with anticoagulants and inferior vena cava filters. Flow fields along the vena cava and an antithrombus filter were studied and compared with a Particle Image Velocimetry (PIV) based model to validate the numerical model. The results show that the fluid–structure interaction (FSI) models are valid and can be used to study the deformations in the inferior vena cava wall using patient-specific geometries.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

In vitro comparison of Günther Tulip and Celect filters. Testing filtering efficiency and pressure drop

  • Nicolas, M.
  • Malvé, M.
  • Peña, E.
  • Martínez, M.A.
  • Leask, R.
In this study, the trapping ability of the Günther Tulip and Celect inferior vena cava filters was evaluated. Thrombus capture rates of the filters were tested in vitro in horizontal position with thrombus diameters of 3 and 6. mm and tube diameter of 19. mm. The filters were tested in centered and tilted positions. Sets of 30 clots were injected into the model and the same process was repeated 20 times for each different condition simulated. Pressure drop experienced along the system was also measured and the percentage of clots captured was recorded. The Günther Tulip filter showed superiority in all cases, trapping almost 100% of 6. mm clots both in an eccentric and tilted position and trapping 81.7% of the 3. mm clots in a centered position and 69.3% in a maximum tilted position. The efficiency of all filters tested decreased as the size of the embolus decreased and as the filter was tilted. The injection of 6 clots raised the pressure drop to 4.1. mmHg, which is a reasonable value that does not cause the obstruction of blood flow through the system.