Skip to main content

TECNICAS DE CONTROL DE ALTAS PRESTACIONES DE MAQUINAS POLIFASICAS MEDIANTE CONVERTIDORES ELECTRONICOS DE POTENCIA Y DE SU INTERCONEXION CON LA RED ELECTRICA TRIFASICA

BES-2013-063149

•
Funding agency name Ministerio de Ciencia e Innovación
Funding agency acronym MICINN
Program Programa Estatal de Promoción del Talento y su Empleabilidad en I+D+i
Subprogram Subprograma Estatal de Formación
Call Contratos Predoctorales
Call year 2013
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSIDAD DE VIGO

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Positive- and negative-sequence current controller with direct discrete-time pole placement for grid-tied converters with LCL filter

  • Pérez Estévez, Diego
  • Doval Gandoy, Jesús
  • Gómez Yepes, Alejandro
  • López Sánchez, Óscar
Traditionally, the current control of grid-tied converters with LCL filter is based on proportional-resonant or proportional-integral controllers, which often need an additional active damping method to achieve stability. These solutions do not permit to place the closed-loop poles in convenient locations when dealing with such high-order plants. This constraint results in degraded reference-tracking and disturbance-rejection responses. On the other hand, the existing methods based on direct pole placement or other modern control strategies, do not control with zero steady-state error both positive and negative sequences of the grid current, but only the positive one. This limitation is undesirable under unbalanced grid conditions. This paper presents a current controller for grid-tied converters with LCL filters based on direct discrete-time pole placement. The proposed controller makes it possible to control both positive and negative sequences of the grid-side current with zero steady-state error. Contrarily to the classical resonant controllers, the closed-loop poles can be placed in convenient locations, yielding a fast response with negligible overshoot and low controller effort. Moreover, no additional damping methods of the resonance are necessary to achieve stable operation, regardless of the switching frequency and LCL filter used. Simulation and experimental results that validate the proposal are presented., Agencia Estatal de Investigación | Ref. DPI2016-75832-R, Ministerio de Economía y Competitividad | Ref. BES-2013-063149
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Enhanced resonant current controller for grid-connected converters with LCL filter

  • Pérez Estévez, Diego
  • Doval Gandoy, Jesús
  • Gómez Yepes, Alejandro
  • López Sánchez, Óscar
  • Baneira Collazo, Fernando
Conventional resonant controllers (RCs) are commonly used in the current control of grid-tied converters with LCL filter due to their advantages, such as zero steady-state error at both fundamental sequences, easy design process, and straightforward implementation. Nevertheless, these traditional solutions do not permit to place the closed-loop poles of the system in convenient locations when dealing with a fourth-order plant model such as the LCL filter plus the computation delay. Therefore, the reference tracking and the disturbance rejection are deficient in terms of transient behavior and depend on the LCL filter. Furthermore, an additional active damping method usually has to be designed in order to ensure stability. This paper presents an enhanced current RC with stable and fast response, negligible overshoot, good disturbance rejection, and low controller effort for grid-tied converters with LCL filter. The developed solution uses a direct discrete-time pole-placement strategy from the classical control theory (using transfer functions), involving two extra filters, to enhance the performance of the RC. In this manner, the complexity of state-space methods from modern control theory is avoided. Simulation and experimental results are provided to verify the effectiveness of the proposed control scheme., Agencia Estatal de Investigación | Ref. DPI2016-75832-R, Ministerio de Economía y Competitividad | Ref. BES-2013-063149
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Estimation method of stator winding resistance for induction motor drives based on DC-signal injection suitable for low inerti

  • Baneira Collazo, Fernando
  • Asiminoaei, Lucian
  • Doval Gandoy, Jesús
  • Delpino, Hernan Andres Miranda
  • Gómez Yepes, Alejandro
  • Godbersen, Jens
Thermal protection is an important aspect that should be considered in ac machines to prevent reduction of the lifetime. For economic reasons, temperature estimation is preferable than the installation of thermal sensors. Thus, several proposals based on dc-signal injection have been reported. Their main drawback is that a certain torque ripple is produced during the injection. On the other hand, the already published filtering techniques proposed to extract the dc components from the phase voltages and currents are based on transforming the per-phase variables to a synchronous reference frame where the fundamental component is eliminated. For this transformation, the rotor position is needed. It is shown in this paper that, due to the disturbance caused in the position due to the torque ripple, the stator resistance estimation is deteriorated when the inertia is not high enough to make this perturbation negligible. In addition, a new technique is also presented to segregate the dc components from the phase currents and voltages, which is robust in terms of accuracy even when the speed/position is perturbed due to the injection. Experimental results validate the theory, Agencia Estatal de Investigación | Ref. DPI2016-75832-R, Ministerio de Economía y Competitividad | Ref. BES-2013-063149