Skip to main content

ESTUDIO EXPERIMENTAL Y NUMERICO DE REGIONES D TRIDIMENSIONALES DE HORMIGON ARMADO: ENCEPADOS Y CALICES

BIA2012-32300

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2012
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Secretaría de Estado de Investigación, Desarrollo e Innovación
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A Simplified Approach for the Ultimate Limit State Analysis of Three-Dimensional Reinforced Concrete Elements

  • Meléndez-Gimeno, Carlos
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
Several advanced constitutive models of concrete have been developed in recent decades, some of which are able to reproduce the behaviour of concrete structures with a high level of accuracy. Yet given their complex formulation, their application by most practitioners can entail some difficulties. This paper describes the adoption of an alternative, simplified comprehensible constitutive model for the ultimate limit state analysis of 3D reinforced concrete structural elements. The proposed model is described and the undertaken assumptions are justified. Different uniaxial stress strain models can be adopted, particularly neglecting the tensile strength of concrete permits to study the goodness of the stress field method and the strut-and-tie method for 3D elements. This model was implemented into a non-linear finite element-based tool developed by the authors. The results of twelve four-pile caps and three socket base column-to-foundation connections are shown. The proposed approach facilitated the identification of the flow of forces and allowed a better understanding of the structural response., The authors wish to thank the Spanish Ministry of Education for the FPU fellowship FPU12-01459 received by the first author, and the Spanish Ministry of Economy and Competitiveness for funding Project BIA 2012-32300.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Refined Three-Dimensional Strut-and-Tie Model for Analysis and Design of Four-Pile Caps

  • Meléndez-Gimeno, Carlos
  • Sagaseta, Juan
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
[EN] Pile caps used in foundations are commonly designed for simple cases of loading and geometry using the strut-and-tie method. This approach is known to provide safe designs and rather conservative predictions of the ultimate failure load of tests. This level of conservatism is due mainly to the large simplifications made in the geometry assumed, which in many cases ignore relevant parameters such as the size of the column. A three-dimensional (3-D) strut-and-tie model is presented for four-pile caps in which the geometry adopted is optimized. The inclination of the direct strut from the column to the pile is obtained analytically through the maximization process of the resisting load carried by the truss assuming different modes of failure (flexural and shear). This approach is shown to provide more accurate predictions of the strength of existing deep pile cap tests with lower scatter compared to design approaches in the literature and the ACI 318 Code., The authors wish to thank the Spanish Ministry of Education for the FPU fellowship FPU12-01459 received by the first author and the funding provided for his research stay at the University of Surrey. The authors also wish to thank the Spanish Ministry of Economy and Competitiveness for funding Project BIA 2012-32300.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Punching shear failure in three-pile caps: Influence of the shear span-depth ratio and secondary reinforcement

  • Miguel-Tortola, Lucia
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
[EN] The strut-and-tie model (STM) is currently established as the best approach for pile cap design. This model leads to efficient estimations of the main reinforcement placed in strips between piles. However, good practices and some international Concrete Design Standards recommend some secondary distributed reinforcement, and even vertical stirrups that are not considered by the STM. An experimental campaign with nine three-pile caps tested by a centered load is presented to show the influence of both secondary reinforcement and the shear span-depth ratio on pile cap strength. The experimental results show a potential redistribution of internal forces in pile caps after yielding of main reinforcement, finally collapsed due to punching. Secondary reinforcement proves efficient to enhance pile cap strength since it takes part in complementary resistance mechanisms. As expected, the failure load increases with shear span-depth ratio reduction. The STM neither captures the effect of this ratio nor considers punching failure. Checking this failure mode is also required for pile caps. The punching formulation of Eurocode 2 allows considering the influence of this ratio, but some interpretation is required whether one deals with pile caps, regarding the effective width of the shear enhancement factor and the definition of the basic control perimeter. A proper definition would prevent unsafe or very conservative results. Therefore, some recommendations for the verification of deep pile caps following the Eurocode 2 are presented. The contribution of vertical stirrups as punching reinforcement is also investigated. The proposed approach is applied to the existing experimental database of three- and four-pile caps to check formulation validity, and conservative predictions with low coefficient of variation are reached., The authors would like to acknowledge the funding received from the Spanish Ministry of Economy and Competitiveness for basic non oriented research projects (BIA2012-32300), which also included a PhD fellowship (BES-2013-063409).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Strength of pile caps under eccentric loads: Experimental study and review of code provisions

  • Miguel-Tortola, Lucia
  • Miguel Sosa, Pedro|||0000-0001-5395-8149
  • Pallarés Rubio, Luis|||0000-0003-2126-2387
[EN] Pile caps are rigid reinforced concrete structures that transfer column loads, generally consisting of a combination of an axial load and bending moments in one or two directions, to the piles. The design formulations of pile caps for more than two piles were derived from the results of experimental tests under a centered load. The practice of checking both punching and shear failure modes is common as described in the literature review, even though these formulations were developed for more slender elements. Currently, Codes ACI 318-14 and EC2 allow designing pile caps with strut-and-tie models or sectional approaches (shear, punching and flexural designs). In this study, 21 full-scale pile caps with different shear span-depth ratios and reinforcement layouts were studied to investigate the effect of eccentric loading on the strength and accuracy of the code formulations. The results show that in eccentrically loaded pile caps, the ultimate load is reduced but the maximum pile reaction increases and the secondary reinforcement proves effective to enhance the pile cap strength. Although the strut-and-tie models (STM) allow eccentric loads to be taken into consideration, they predict a much lower peak load than that observed at the experimental results and do not adequately reflect either the influence of slenderness or the failure mode. In general the sectional approach provided by Codes ACI-318-14, EC2 and MC-2010 (Level I of Approximation) lead to safe predictions of the peak load but do not always correctly predict the failure mode. The ultimate load predicted by EC-2 formulation comes closest to the experimental peak load, accurately reflects the influence of slenderness and the effect of secondary reinforcement, however, additional assumptions need to be made for its application. The ACI formulation complemented by the CRSI-2008 Special Investigation for deep pile caps is the safest but does not adequately capture the effect of horizontal and vertical secondary reinforcement. The MC2010 LoAI formulation is also conservative but does not detect the influence of slenderness or the contribution of secondary reinforcement., The authors wish to express their gratitude for the financial support (BIA2012-32300 and BIA2015-64672-C4-4-R) received from the Spanish Ministry of Economy and Competitiveness, which enabled the experimental campaign to be carried out, also for the PhD fellowship (BES-2013-063409).