DURABILIDAD Y VIDA UTIL DEL HORMIGON DE MUY ALTO RENDIMIENTO

BIA2016-78460-C3-3-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2016
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Real-time corrosion monitoring of an ultra-high performance fibre-reinforced concrete offshore raft by using an autonomous sensor sytem

  • Ramón Zamora, José Enrique
  • Bataller Prats, Román
  • López, Juan A.
  • Soto Camino, Juan
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
  • Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554
[EN] The excellent high-durability features of ultra-high performance fibre-reinforced concrete (UHPFRC) have been verified in laboratory studies, but its performance under service conditions are being studied. Indeed, structural health monitoring (SHM) can be considered an efficient strategy to assess built structures in which concrete matrix performance differs from that those found when assessing laboratory samples (variable actions, cracking, etc.). This work presents INESSCOM, an automated corrosion rate monitoring system, as an innovative support to SHM strategy to monitor UHPFRC structures in terms of durability. Its innovation lies in its durable and multi-parametric sensor designed to be embedded in multiple parts of a structure. The results from pre-vious laboratory tests and those obtained during real-time monitoring of an offshore UHPFRC raft are presented. Acceptable deviation of 20% was obtained in corrosion rate measurements with the advantageous reference-electrode-free cell of the sensor with respect to the classical three-electrode cell. Furthermore, sensor provided accurate corrosion measurements in UHPFRC despite its extremely high electrical resistivity and large amount of steel fibres. After 17-month monitoring of the UHPFRC raft, excellent perfor-mance was evidenced under service conditions with corrosion rate values always <0.1 ¿A/cm2. Conversely, corrosion rate reached 0.4 ¿A/cm2 in a con-ventional concrete specimen installed for comparison. Corrosion initiation and propagation stages were clearly defined through the corrosion-penetration-damage (¿m) diagram obtained for the specimen. Present work positions INESSCOM as an innovative support to structural health monitoring strategy in UHPFRC structures., UPV, Grant/Award Number: SP20180245; Spanish Ministry of Economy and Competitiveness, Grant/Award Numbers: BIA2016-78460-C3-3-R, PID2020-119744RB-C21, PID2020-119744RB-C22; Spanish Ministry of Science and Innovation, Grant/Award Number: FPU13/00911
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Influence of the reference electrode position on the intensity corrosion measurements in reinforced concrete

  • Lliso-Ferrando, Josep Ramon|||0000-0002-2457-9024
  • Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554
  • Gasch, Isabel|||0000-0001-7036-4481
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
[EN] Corrosion of the steel embedded in reinforced concrete is one the biggest problems that affects concrete structures durability. High alkalinity of this material protects the steel creating a passive layer, which chloride penetration or concrete carbonation destroy. In favourable conditions, as high humidity or oxygen presence, once the passive layer has been destroyed, active corrosion of the steel promotes loss of profile and reduces the adherence. The damage can be appreciated outside the elements once it is really advanced. Using methods to detect the beginning of active corrosion and control the damage can be a helpful tool to avoid expensive repairs after a late detection of the phenomena [1]. Including a sensor network in structures will let monitor the corrosion processes inside them. Voltammetric analysis using sensors requires a counter electrode (CE) and a reference electrode (RE). Due to economic issues and maintenance, most times it is just one reference embedded. This fact generates a large distance between the reference electrode and some sensors, incurring a wrong analysed values lecture. The aim of this paper is analysing the influence of the distance between sensors and the reference electrodes to get several measures which can let us arrange a statistic reliability. In this case, an external reference electrode will be used, letting move it, for measure at different distances from the sensor. For that purpose, in this studio will be used the voltammetric method, developed by Alcañiz et Al [2]., The authors would like to express their gratitude to the Universitat Politècnica de València for the pre-doctoral scholarship granted to Josep Ramon Lliso Ferrando (FPI-UPV2018), and the financial support from the Spanish Ministry of Economy and Competitiveness by the national program of oriented research, development and Innovation to societal challenges (ref. BIA2016-78460-C3-3-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Improved Tafel-Based Potentiostatic Approach for Corrosion Rate Monitoring of Reinforcing Steel

  • Ramón, José Enrique
  • Martínez, Isabel
  • Soto Camino, Juan
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
[EN] Potential step voltammetry (PSV) was introduced in earlier works as an advantageous alternative to traditional methods for measuring corrosion rate in reinforced concrete. The present study aims to improve PSV to maximize its applicability in corrosion rate monitoring, that is, beyond the narrowly-defined steel¿concrete systems in which was initially validated. It was therefore identified necessary to address the most suitable PSV pulse amplitudes to accurately obtain the Tafel lines and, therefore, corrosion rate in steel-mortar systems with well-differentiated ohmic drop. PSV findings were compared to reference methods, i.e. Tafel intersection and linear polarization resistance. As a novelty, we propose a procedure to improve the reliability of the PSV-determined Tafel lines, which is based on three protocols (P1, P2 and P3). P1 consists of a specific pulse sequence to accurately characterize the morphology of the polarization curve without disturbing the system. P2 consists of two short pulses for determining the ohmic drop compensation factor. Finally, P3 consists of a simple calculation procedure to accurately adjust the PSV pulse amplitudes (V) to the steel¿concrete system assessed, thus obviating the need for preset values and, therefore, ensuring accurate corrosion rate results. The procedure proposed is intended to improve PSV with a view to its consolidation as a reliable tool for the unsupervised monitoring of real structures., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work was supported by the pre-doctoral scholarship granted to Jose Enrique Ramon Zamora by the Spanish Ministry of Science and Innovation (Grant Number FPU13/00911). We would also like to acknowledge financial support from the Spanish Ministry of Science and Innovation through the national programs of oriented research, development and innovation to societal challenges (Project Numbers BIA2016-78460-C33-R, PID2020-119744RB-C21 and PID2020-119744RB-C22). To the Universitat Politecnica de Valencia for the financial support in the project "Ayudas a Primeros Proyectos de Investigacion (PAID-0618)"-SP20180245.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Corrosion resistance of ultra-high performance fibre- reinforced concrete

  • Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554
  • Lliso-Ferrando, Josep Ramon|||0000-0002-2457-9024
  • Ramón Zamora, José Enrique
  • Soto Camino, Juan
[EN] The corrosion resistance of ultra-high performance concrete (UH) made with different fibre contents and under distinct curing conditions was studied. No signs of carbonation were observed after 1 year of accelerated carbonation testing (3% CO2). The fibreless UHs¿ electrical resistivity was above 5000 ¿·m, although these values were 2-fold higher than a UH with 1% fibres and approximately 5-fold higher than a UH with 2% fibres. Concrete resistance to chloride penetration was also extremely high (the diffusion coefficient equalled 1.3·10¿13 m2/s) and curing temperatures of 60 °C or 90 °C improved even more these properties, while lack of curing made them slightly worse. Given these excellent properties, the corrosion rate in specimens submerged in chloride solution for 1 year was negligible (iCORR from 0.007 to 0.025 µA/cm2). These values remained stable with time, unlike the 50 MPa concrete at 2 months when iCORR starting to increase and was 12-fold higher after 1 year. The time estimated for corrosion onset in UH is on average about 150-fold higher than that of 50 MPa., Authors thank to the Spanish Government the financial support of project BIA2016-78460-C3-3-R and to the European Union¿s Horizon 2020 the financial support of ReSHEALience project (Grant Agreement No. 760824). Furthermore, authors would like to express their gratitude for the support of the Universitat Politecnica de Valencia. Funding for open access charge: CRUE-Universitat Politecnica de Valencia. The predoctoral scholarship granted to Josep Ramon Lliso Ferrando within the program "Formacion de Personal Investigador" from the Universitat Politecnica de Valencia (FPI-UPV-2018) is also gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Characterization of electrochemical systems using potential step voltammetry. Part II: Modeling of reversible systems

  • Martínez-Ibernón, Ana|||0000-0003-2136-5650
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
  • Gasch, Isabel|||0000-0001-7036-4481
  • Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554
  • Alcañiz Fillol, Miguel|||0000-0002-4579-9210
  • Ramón Zamora, José Enrique
  • Soto Camino, Juan
[EN] This study was carried out to compare the results obtained using potential step voltammetry and linear sweep voltammetry with a rotating gold disc electrode (RDE), when models based on equivalent circuits (EC) were used. The results lead to an equivalent circuit model that allows us to interpret the electrochemical behavior of aqueous solutions containing Fe(CN)(6)(-4) and Fe(CN)(6)(-3). With this model, we determined the values of the electrical resistance of the medium (R-s) as well as its polarization resistance (R-p), and established correlations between these values and the kinetic parameters of the system. The proposal highlights the need to introduce a new component for modeling using EC, which we have called the electrochemical diode. (C) 2019 Elsevier Ltd. All rights reserved., The authors gratefully acknowledge the financial support of BIA2016-78460-C3-3-R, MAT2015-64139-C4-3-R and RTI2018-100910-B-C43 (MINECO/FEDER) projects. We would also like to extend our appreciation for the pre-doctoral FPU scholarships (University Teacher Training scholarship) granted to Ana Martinez Ibernon (FPU 16/00723) and Jose Enrique Ramon Zamora (FPU13/00911) by the Spanish Ministry of Science and Innovation.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Potential step voltammetry: An approach to corrosion rate measurement of reinforcements in concrete

  • Ramón, J.E.
  • Bataller Prats, Román
  • Soto Camino, Juan
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
  • Alcañiz Fillol, Miguel|||0000-0002-4579-9210
  • Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554
[EN] This paper presents a Potentiostatic Step Voltammetry approach to corrosion rate measurement of reinforcements in concrete. We have termed this approach PSV-TE since it is based on the Tafel extrapolation method, but with the added advantage that long and slow potentiodynamic scans are no longer required to obtain the Tafel slopes. In this way, the irreversible polarization of rebars is prevented, so PSV-TE is considered to be a non-destructive method. The Tafel slopes are obtained by fitting the current-time response of the system to a theoretical model which we have outlined and validated previously. In this way, the concrete's electrical resistance and double layer capacity are also obtained. In this study, the optimal PSV-TE design has been established and validated on a range of reinforced concrete specimens. Results show minimal deviation between PSV-TE and reference methods. Therefore, PSV-TE is part of the corrosion monitoring system we have patented., This work was supported by a pre-doctoral scholarship granted to Jose Enrique Ramon Zamora by the Spanish Ministry of Science and Innovation [grant number FPU13/00911]. We would also like to acknowledge financial support from the Spanish Ministry of Economy and Competitiveness through the national program of oriented research, development and innovation to societal challenges [project number BIA2016-78460-C3-3-R]. The research activity reported in this paper has been performed in the framework of the ReSHEALience project which has received funding from the European Union's Horizon 2020 research and innovation program [number 760824]. We extend our appreciation to Rafa Calabuig and Jesus Martinez, Material Laboratory technicians of the ETSIE of the Universitat Politecnica de Valencia, for their invaluable cooperation in the experimental work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Characterization of electrochemical systems using potential step voltammetry. Part I: Modeling by means of equivalent circuits

  • Ramón Zamora, José Enrique
  • Fraile Muñoz, Rubén
  • Bataller Prats, Román
  • Soto Camino, Juan
  • Martínez-Ibernón, Ana|||0000-0003-2136-5650
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
  • Alcañiz Fillol, Miguel|||0000-0002-4579-9210
  • Garcia-Breijo, Eduardo|||0000-0002-9745-8485
[EN] Potential step voltammetry is used to characterize the resistive and capacitive properties of electrochemical systems. Within those systems, electrochemical processes are modeled by means of equivalent circuits (ECs). In this study, we established and experimentally validated algebraic expressions describing the electrical response of those ECs. We then analyzed the features that allow significant differentiation between the ECs. Finally, we have proposed a method to graphically visualize and analyze the electrical response of the circuit to a potential step sequence. The application of this method to real electrochemical systems will allow us to not only identify the electrochemical processes taking place in an experiment but to also assess parameters such as the double layer capacitance, the solution resistance, and the polarization resistance of the redox process., Financial support from the Spanish Government (FEDER project BIA2016-78460-C3-3-R, MAT2015-64139-C4-3-R and RTI2018-100910-B-C43 (MINECO/FEDER) projects) is gratefully acknowledged. The predoctoral scholarships granted to Ana Martinez Ibernon (FPU 16/00723) and to Jose Enrique Ramon Zamora within the program "Formacion de Profesorado Universitario'' from the Ministry of Education, Culture and Sport (FPU 13/00911) are also gratefully acknowledged.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Porous Structure of Ultra-High-Performance Fibre-Reinforced Concretes

  • Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554
  • Lliso-Ferrando, Josep Ramon|||0000-0002-2457-9024
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
  • Roig-Flores, Marta
[EN] The aim of this experimental work was to study the porous structure of Ultra-High-Performance Fibre-Reinforced Concretes (UH) made with different fibre volume contents (0%, 1%, 2%) under several curing conditions (laboratory environment, 20 degrees C, 60 degrees C, 90 degrees C), comparing the results with those recorded for ordinary, high strength and very high strength concretes. Scanning electron microscopy, mercury intrusion porosimetry, thermogravimetry, water absorption and oxygen permeability tests were carried out. The results showed a low portlandite content in UH (in the order of 75% lower than in concrete C50) and a low degree of hydration, but they rise with curing temperature. These concretes have a very fine porous structure, with a high concentration of pores on the nanoscale level, below 0.05 mu m. Their porosity accessible to water is consequently around 7-fold lower than in conventional (C30), 6-fold lower than in high-strength (C50) and 4-fold lower than in very high-strength (C90) concretes. Their oxygen permeability is at least one order of magnitude lower than in C90, two orders of magnitude lower than in C50 and three orders of magnitude lower than in C30. The percentage of added steel fibre does not affect the UH porous structure, This research was funded by Ministerio de Economia Y Competitividad (Agencia Estatal de Investigacion) of the Spanish Government, Grant number BIA2016-78460-C3-3-R
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Influence of Corrosion-Inhibiting Monolayers on the Bond Strength and Durability of Reinforced Concrete Structures Under Service Conditions

  • Monzón-Bello, Pablo
  • Vengut-Tro, Roberto|||0009-0001-8125-2570
  • Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554
  • Soto Camino, Juan
[EN] Corrosion protection in reinforced concrete structures exposed to aggressive environments remains a critical challenge in civil and architectural engineering. One promising approach involves the application of corrosion-inhibiting monolayers on the reinforcement, such as those formed using 4-aminobenzoic acid. Two methods have previously been employed to generate these monolayers: one relying on the adhesion of an organic compound and the other utilising an externally modified approach via electrolysis. This study assesses the influence of this treatment on the steel-concrete bond strength and durability, both critical properties for the structural performance of reinforced concrete under service conditions. For this purpose, pull-out tests were performed on specimens subjected to load-unload cycles to analyse bond behaviour and monolayer integrity. The results indicate that these treatments do not adversely affect the bond strength between reinforcement and concrete. Furthermore, the rebars treated with the inhibitor exhibit less corrosion damage than the untreated rebars. This fact is particularly significant in the rebars treated using the natural adhesion method, with the steel section loss being 32-37% lower than in the untreated rebars. These findings support the feasibility of applying this treatment without compromising structural functionality., This research was funded by the Spanish Government, grant number BIA2016-78460-C3-3-R. The Universitat Politecnica de Valencia. The pre-doctoral scholarships granted to Roberto Vengut Tro within the programmes "Formacion de Personal Investigador" from the Universitat Politecnica de Valencia (FPI-UPV-2022) and "Personal Investigador Predoctoral" from the Generalitat Valenciana (CIACIF/2022/076).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

PLS multivariate analysis applied to corrosion studies on reinforced concrete

  • Monzón-Bello, Pablo
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
  • Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554
  • Ramón Zamora, José Enrique
  • Soto Camino, Juan
  • Palací-López, Daniel
[EN] There are few techniques available to calculate the corrosion rate (i(corr)) of reinforcing steel in concrete structures. This is due not only to a lack of instrumentation but also because it is necessary to take into account that polarization can irreversibly modify the metal surface and can affect the results or the future state of the metal. This is the reason some researchers prefer to test reinforcing steel with reversible techniques. The main objective of this study is to predict the corrosion rate of reinforced concrete using electrochemical methods combined with statistical tools such as multivariate analysis. Using reinforcements embedded in mortar samples, the corrosion rates were determined at different ages using the Tafel method, and values obtained were compared with other techniques: linear polarization resistance (LPR), potentiostatic pulse testing (PPT), and AC electrochemical impedance spectroscopy (EIS). In addition, these values were compared to those obtained using a mixed technique based on partial least squares (PLS). With this technique, we were able to automatically analyze the current data obtained from LPR, PPT, and EIS and to predict the i(corr) value. The study allows us to conclude that it is possible to obtain reliable i(corr) values, very close to those obtained with the Tafel method by using PLS combined with PPT or LPR. Furthermore, it presents several advantages, such as being able to directly treat data without requiring an established Stern-Geary constant (B) for LPR and not having to use an equivalent circuit (EC) in EIS to calculate i(corr) because only the impedance spectra are necessary., Spanish Ministry of Economy and Competitiveness, Grant/Award Number: BIA2016-78460-C3-3-R; Spanish Ministry of Science and Innovation, Grant/Award Number: FPU 13/00911 and FPU16/00723
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

An Embedded-Sensor Approach for Concrete Resistivity Measurement in On-Site Corrosion Monitoring: Cell Constants Determination

  • Ramón, Jose Enrique
  • Martínez, Isabel
  • Soto Camino, Juan
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
[EN] The concrete electrical resistivity is a prominent parameter in structural health monitoring, since, along with corrosion potential, it provides relevant qualitative diagnosis of the reinforcement corrosion. This study proposes a simple expression to reliable determine resistivity from the concrete electrical resistance (R-E) provided by the corrosion sensor of the Integrated Network of Sensors for Smart Corrosion Monitoring (INESSCOM) we have developed. The novelty here is that distinct from common resistivity sensors, the cell constants obtained by the proposed expression are intended to be valid for any sensor implementation scenario. This was ensured by studying most significant geometrical features of the sensor in a wide set of calibration solutions. This embedded-sensor approach is intended to be applicable for R-E measurements obtained both using potential step voltammetry (PSV, used in the INESSCOM sensor for corrosion rate measurement) and alternating current methods. In this regard, we present a simple protocol to reliably determine R-E, and therefore resistivity, from PSV measurements. It consists in adding a very short potentiostatic pulse to the original technique. In this way, we are able to easy monitor resistivity along with corrosion rate through a single sensor, an advantage which is not usual in structural health monitoring., This research was funded by the pre-doctoral scholarship granted to Jose Enrique Ramon Zamora by the Spanish Ministry of Science and Innovation, grant number FPU13/00911. Funding was also provided by the Spanish Ministry of Economy and Competitiveness under the national program for research, development and innovation geared to societal challenges; project number BIA2016-78460-C3-3-R. The research activity reported in this paper has been partially possible thanks to the project Voltammetric Electronic Tongue for Durability Control in Concrete funded by the Universitat Politecnica de Valencia, project number SP20180245.