Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Real-time corrosion monitoring of an ultra-high performance fibre-reinforced concrete offshore raft by using an autonomous sensor sytem

  • Ramón Zamora, José Enrique
  • Bataller Prats, Román
  • López, Juan A.
  • Soto Camino, Juan
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
  • Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554
[EN] The excellent high-durability features of ultra-high performance fibre-reinforced concrete (UHPFRC) have been verified in laboratory studies, but its performance under service conditions are being studied. Indeed, structural health monitoring (SHM) can be considered an efficient strategy to assess built structures in which concrete matrix performance differs from that those found when assessing laboratory samples (variable actions, cracking, etc.). This work presents INESSCOM, an automated corrosion rate monitoring system, as an innovative support to SHM strategy to monitor UHPFRC structures in terms of durability. Its innovation lies in its durable and multi-parametric sensor designed to be embedded in multiple parts of a structure. The results from pre-vious laboratory tests and those obtained during real-time monitoring of an offshore UHPFRC raft are presented. Acceptable deviation of 20% was obtained in corrosion rate measurements with the advantageous reference-electrode-free cell of the sensor with respect to the classical three-electrode cell. Furthermore, sensor provided accurate corrosion measurements in UHPFRC despite its extremely high electrical resistivity and large amount of steel fibres. After 17-month monitoring of the UHPFRC raft, excellent perfor-mance was evidenced under service conditions with corrosion rate values always <0.1 ¿A/cm2. Conversely, corrosion rate reached 0.4 ¿A/cm2 in a con-ventional concrete specimen installed for comparison. Corrosion initiation and propagation stages were clearly defined through the corrosion-penetration-damage (¿m) diagram obtained for the specimen. Present work positions INESSCOM as an innovative support to structural health monitoring strategy in UHPFRC structures., UPV, Grant/Award Number: SP20180245; Spanish Ministry of Economy and Competitiveness, Grant/Award Numbers: BIA2016-78460-C3-3-R, PID2020-119744RB-C21, PID2020-119744RB-C22; Spanish Ministry of Science and Innovation, Grant/Award Number: FPU13/00911
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Improved Tafel-Based Potentiostatic Approach for Corrosion Rate Monitoring of Reinforcing Steel

  • Ramón, José Enrique
  • Martínez, Isabel
  • Soto Camino, Juan
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
[EN] Potential step voltammetry (PSV) was introduced in earlier works as an advantageous alternative to traditional methods for measuring corrosion rate in reinforced concrete. The present study aims to improve PSV to maximize its applicability in corrosion rate monitoring, that is, beyond the narrowly-defined steel¿concrete systems in which was initially validated. It was therefore identified necessary to address the most suitable PSV pulse amplitudes to accurately obtain the Tafel lines and, therefore, corrosion rate in steel-mortar systems with well-differentiated ohmic drop. PSV findings were compared to reference methods, i.e. Tafel intersection and linear polarization resistance. As a novelty, we propose a procedure to improve the reliability of the PSV-determined Tafel lines, which is based on three protocols (P1, P2 and P3). P1 consists of a specific pulse sequence to accurately characterize the morphology of the polarization curve without disturbing the system. P2 consists of two short pulses for determining the ohmic drop compensation factor. Finally, P3 consists of a simple calculation procedure to accurately adjust the PSV pulse amplitudes (V) to the steel¿concrete system assessed, thus obviating the need for preset values and, therefore, ensuring accurate corrosion rate results. The procedure proposed is intended to improve PSV with a view to its consolidation as a reliable tool for the unsupervised monitoring of real structures., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work was supported by the pre-doctoral scholarship granted to Jose Enrique Ramon Zamora by the Spanish Ministry of Science and Innovation (Grant Number FPU13/00911). We would also like to acknowledge financial support from the Spanish Ministry of Science and Innovation through the national programs of oriented research, development and innovation to societal challenges (Project Numbers BIA2016-78460-C33-R, PID2020-119744RB-C21 and PID2020-119744RB-C22). To the Universitat Politecnica de Valencia for the financial support in the project "Ayudas a Primeros Proyectos de Investigacion (PAID-0618)"-SP20180245.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A Concrete Resistivity Method Based on a Simple Measuring Cell for Onsite Corrosion Monitoring: Study on Concrete Under Varying Conditions

  • Ramón, J. E.
  • Martínez, I.
  • Castillo, A.
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
  • Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554
[EN] Concrete resistivity (rho) is commonly monitored in situ using sensors based on the rebar-disc (RDM) or four-electrode (FEM) methods. This study validates, for the first time in reinforced concrete, an innovative corrosion sensor approach (CSA) previously tested only in simulated pore solutions. The CSA uses a single embedded two-electrode sensor that also allows the corrosion rate, offering a significant advantage for structural health monitoring. CSA resistivity values were broadly consistent with those from established reference methods: 2.9% higher than the RDM and 20% lower than the two-electrode method. Larger differences were observed with the FEM, decreasing when a finite-element cell factor (103%) was applied instead of one for semi-infinite elements (208%). This trend aligns with expected differences between FEM surface resistivity and bulk values. Additionally, a simple correction factor is proposed to normalise rho to the reference temperature (T) of 20 degrees C, expressed as 1/(aexp((b)T)), with a and b equal to 1.7251 and 0.027 for low-resistivity concretes and 2.4851 and 0.046 for medium- to high-resistivity concretes. A general model for the full resistivity range yielded a = 2.0687 and b = 0.036. While further research is needed to explore wider corrosion scenarios, the results highlight the potential of the CSA as a practical tool for both laboratory and in situ corrosion assessment., This research was supported by the Ministry of Economy and Competitiveness (Ministerio de Econom & imath;a y Competitividad) of Spain [PID2020-119744RB-C21 and PID2020-119744RB-C22] and the Universitat Politecnica de Valencia [SP20180245].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Stainless Steel Voltammetric Sensor to Monitor Variations in Oxygen and Humidity Availability in Reinforcement Concrete Structures

  • Martínez-Ibernón, Ana|||0000-0003-2136-5650
  • Lliso-Ferrando, Josep Ramon|||0000-0002-2457-9024
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
  • Soto Camino, Juan
[EN] The present work presents the results obtained with a stainless steel (SS) voltammetric sensor to detect variations in humidity (H2O) and oxygen (O2) availability in concretes. First, studies in solution were run by preparing several solutions to represent the different conditions that can be found in concrete pores. Second, the sensor's response was studied by varying O2 availability by argon or synthetic air bubbling. Then concrete conditions with different degrees of carbonation were simulated using solutions with a pH between 13 and 8.45. After characterization in solution, a study by means of concrete samples with several water/cement ratios (0.6, 0.5 and 0.4) was performed, in which sensors were embedded and studied under different O2 and H2O saturation conditions. The obtained results revealed that with the voltagram, it is possible to evaluate O2 availability variation from the slopes of the lines identified logarithmically in the voltagram for the obtained cathodic sweeping. All the results obtained with the sensor were correlated/validated by standard assays to characterize porosity in hardened concretes., The authors would like to express their gratitude to the Spanish Ministry of Science and Innovation for the pre-doctoral scholarship granted to Ana Martinez Ibernon (FPU 16/00723). To the Universitat Politecnica de Valencia for the financial support in the project "Ayudas a Primeros Proyectos de Investigacion (PAID-06-18): Lengua Electronica Voltametrica para el control de durabilidad en hormigones, SP20180245"
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Hydronium Detection in Hardened Concrete

  • Martínez-Ibernón, Ana|||0000-0003-2136-5650
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
  • Gasch, Isabel|||0000-0001-7036-4481
  • Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554
[EN] The monitoring of reinforced concrete structures allows us to detect the presence of aggressive agents into of the concrete matrix, on site and in a real time. These aggressive agents can produce the unexpected failure of the structures, thus discovering their presence is a fundamental aspect in the preservation of people safety and the durability of the structure. On the other hand, helps to reduce the cost of maintenance and repair operations, due to allow us to identify the problems faster, minimizing the intervention to be done. The present research paper was focused in the hydronium detection; the reduction of this species generates hydrogen, the hydrogen produces the embrittlement and cracking of the steel, which seriously compromises the right behaviour of the structure. The problem of hydrogen appears in industries such as ammonia processing or petrochemistry industries and nuclear power plants. All of them are industries in which a failure seriously compromises the welfare of people and the environment. Therefore, the detection of hydrogen penetration in reinforcement concrete structures in these cases are very interesting. In this study, with the purpose to detect the hydronium or hydrogen in the hardened concrete matrices is proposed the use of voltammetric sensor, which is part of a multisensory system called Electronic-Tongue. This is a preliminary study. The objective of these initial steps was to evaluate the detection capability of the sensor. Currently, have been designing a sequential test in order to evaluate the sensor in different partial hydrogen pressures with the purpose to develop mathematical models to the hydronium or hydrogen detection and quantification in hardened concrete matrix., The authors would like to express their gratitude to the Spanish Ministry of Science and Innovation for the pre-doctoral scholarship granted to Ana Martínez Ibernón (FPU 16/00723). Also, to the Universitat Politècnica de València for the financial support in the project ¿Ayudas a Primeros Proyectos de Investigación (PAID-06-18)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

An Embedded-Sensor Approach for Concrete Resistivity Measurement in On-Site Corrosion Monitoring: Cell Constants Determination

  • Ramón, Jose Enrique
  • Martínez, Isabel
  • Soto Camino, Juan
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
[EN] The concrete electrical resistivity is a prominent parameter in structural health monitoring, since, along with corrosion potential, it provides relevant qualitative diagnosis of the reinforcement corrosion. This study proposes a simple expression to reliable determine resistivity from the concrete electrical resistance (R-E) provided by the corrosion sensor of the Integrated Network of Sensors for Smart Corrosion Monitoring (INESSCOM) we have developed. The novelty here is that distinct from common resistivity sensors, the cell constants obtained by the proposed expression are intended to be valid for any sensor implementation scenario. This was ensured by studying most significant geometrical features of the sensor in a wide set of calibration solutions. This embedded-sensor approach is intended to be applicable for R-E measurements obtained both using potential step voltammetry (PSV, used in the INESSCOM sensor for corrosion rate measurement) and alternating current methods. In this regard, we present a simple protocol to reliably determine R-E, and therefore resistivity, from PSV measurements. It consists in adding a very short potentiostatic pulse to the original technique. In this way, we are able to easy monitor resistivity along with corrosion rate through a single sensor, an advantage which is not usual in structural health monitoring., This research was funded by the pre-doctoral scholarship granted to Jose Enrique Ramon Zamora by the Spanish Ministry of Science and Innovation, grant number FPU13/00911. Funding was also provided by the Spanish Ministry of Economy and Competitiveness under the national program for research, development and innovation geared to societal challenges; project number BIA2016-78460-C3-3-R. The research activity reported in this paper has been partially possible thanks to the project Voltammetric Electronic Tongue for Durability Control in Concrete funded by the Universitat Politecnica de Valencia, project number SP20180245.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Distributed Embedded System for Multiparametric Assessment of Infrastructure Durability Using Electrochemical Techniques

  • Monreal-Trigo, Javier|||0000-0002-4067-1867
  • Alcañiz Fillol, Miguel|||0000-0002-4579-9210
  • Gandía-Romero, Jose M.|||0000-0003-0257-3286
  • Ramón, José Enrique
  • Bataller, Román
  • Soto Camino, Juan
[ES] Presentamos un sistema autónomo que monitoriza de forma remota el estado de las estructuras de hormigón armado. Este sistema realiza un seguimiento en tiempo real de la tasa de corrosión de las barras de refuerzo (iCORR), junto con otros parámetros relevantes como la temperatura, el potencial de corrosión (ECORR) y la resistencia eléctrica del hormigón (RE), en varios puntos de control de la estructura utilizando sensores incrustados. El valor de iCORR se obtiene aplicando una nueva técnica de polarización electroquímica de bajo estrés a los sensores de corrosión. El sistema electrónico personalizado gestiona la red de sensores, que consiste en una placa de medición por cada punto de control conectada a un ordenador de placa única central encargado de procesar los datos de medición y subir los resultados a un servidor mediante una conexión 4G. En este trabajo, reportamos los resultados obtenidos tras la implementación del sistema de sensores en un muro de hormigón armado, donde se monitorearon dos áreas representativas bien diferenciadas. Los parámetros de corrosión obtenidos mostraron valores consistentes. Se obtuvieron conclusiones similares con los valores de ECORR registrados en las barras de refuerzo. Con el seguimiento de iCORR, se construyó un diagrama de penetración del daño por corrosión. Este diagrama es particularmente útil para identificar eventos críticos durante el periodo de propagación de la corrosión y para estimar la vida útil de las estructuras. Por lo tanto, el sistema se presenta como una herramienta útil para el mantenimiento estructural y las predicciones de vida útil de nuevas estructuras., [EN] We present an autonomous system that remotely monitors the state of reinforced concrete structures. This system performs real-time follow-up of the corrosion rate of rebars (iCORR), along with other relevant parameters such as temperature, corrosion potential (ECORR), and electrical resistance of concrete (RE), at many of a structure¿s control points by using embedded sensors. iCORR is obtained by applying a novel low-stress electrochemical polarization technique to corrosion sensors. The custom electronic system manages the sensor network, consisting of a measurement board per control point connected to a central single-board computer in charge of processing measurement data and uploading results to a server via 4G connection. In this work, we report the results obtained after implementing the sensor system into a reinforced concrete wall, where two well-differentiated representative areas were monitored. The obtained corrosion parameters showed consistent values. Similar conclusions are obtained with ECORR recorded in rebars. With the iCORR follow-up, the corrosion penetration damage diagram is built. This diagram is particularly useful for identifying critical events during the corrosion propagation period and to be able to estimate structures¿ service life. Hence, the system is presented as a useful tool for the structural maintenance and service life predictions of new structures., This research was supported by the Spanish Ministry of Science, Innovation and Universities via a doctoral grant to Jose Enrique Ramon Zamora (FPU13/00911) and to Javier Monreal Trigo (FPU17/03239). Funding was also provided by the Spanish Ministry of Science and Innovation under project numbers PID2021-126304OB-C44, PID2020-119744RB-C21 and PID2020-119744RB-C22, and by the Universitat Politecnica de Valencia under project number SP20180245 'Voltammetric Electronic Tongue for Durability Control in Concrete'.