Skip to main content

COLAPSO PROGRESIVO Y ROBUSTEZ EN EDIFICIOS CON ESTRUCTURA PREFABRICADA DE HORMIGON

BIA2017-88322-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Tests on a Full-Scale Precast Building for Robustness Assessment

  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] As modern society faces unprecedented challenges related to climate stability and conflict, the need to design more sustainable and resilient buildings is undeniable. Several studies show that building with precast concrete components can result in significant advantages with respect to sustainability. However, the fact that such structures exhibit clear lines of weakness at the joints between elements can make them more vulnerable to progressive collapse. Although this can be overcome by adequate detailing of connections, there exist several uncertain factors which may affect the interaction between different precast elements and the global behaviour of such structural systems. This means that experimental testing is usually required for safe development of adequate solutions. Despite this fact, there have been very few studies on the robustness of precast concrete structures when compared to research on cast-in-place and steel structures. As such, this work presents the results of an ambitious experimental campaign involving the sudden removal of 3 different columns from a specifically built 15 m x 12 m two-storey precast concrete building incorporating simple and practical solutions to enhance robustness., This article is part of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union¿s Horizon 2020 research and innovation programme (Grant agreement No. 101000396). The authors would like to acknowledge the funding received through grant BIA2017-88322-R-AR funded by MCIN/AEI/ 10.13039/501100011033 and ¿ERDF A way of making Europe¿. The authors would also like to express their gratitude for funding received under the postdoctoral programs of Generalitat Valenciana/European Social Fund [APOSTD/2019/101] and grant IJC2020-042642-I funded by MCIN/AEI/ 10.13039/501100011033 and by ¿European Union NextGenerationEU/PRTR¿. The help and support provided by Ayman El-Fouly (Applied Science International) for performing simulations in ELS is also gratefully acknowledged. Finally, the authors are also grateful for the invaluable cooperation of the Levantina, Ingeniería y Construcción S.L. (LIC) company, and the contribution of members and collaborators of the Building Resilient research group.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Large-Scale Tests on RC Purpose-Built Buildings for Improving Robustness

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Adam, Jose M|||0000-0002-9205-8458
  • Mezquida-Alcaraz, Eduardo J.
[EN] Although recent years have been marked by a substantial research effort on the progressive collapse of steel as well as cast-in-place and precast concrete structures, the fact is that almost all studies are focused on reduced-scale tests, tests on isolated frame structures, tests on substructures or analytical and numerical analysis. Within this context, large-scale tests avoid size effects and allow all resisting mechanisms that a structure can develop after an initial-local failure to be studied. This paper presents the case of large-scale tests performed on two purpose-built buildings: one made of cast-in-place concrete and the other with precast concrete elements. In both cases, sudden column removal scenarios were considered for the robustness assessment of the structural system. The structures were provided with simple solutions to enhance the robustness and arrest progressive collapse initiated by the sudden failure of a column. The cast-in-place concrete building had two 3 m high floors, with 2 × 2 bays of 5 m span length. The total in-plan dimensions of the building were 10 × 10 m2. This building was subjected to sudden corner column failure scenarios with and without the presence of infill masonry walls. The precast concrete structure also had two 3 m high floors, with 3 × 2 bays of 5 m and 6 m span, respectively. The total in-plan dimensions of the building were 15 × 12 m2. This building was subjected to sudden column failure scenarios for three different tests, involving the removal of: a corner column, an edge column in a frame parallel to the direction of one-way hollow-core slabs, and an edge column in a frame perpendicular to the one-way slabs. This paper presents and discusses a summary of the results and outcomes of these studies., The work for the cast-in-place concrete building was carried out with the support of a 2017 Leonardo Grant for Researchers and Cultural Creators from the BBVA Foundation. The work for the precast concrete building was carried out with the funding received through grant BIA2017-88322-R-AR funded by MCIN/AEI/10.13039/501100011033 and ERDF A way of making Europe. This research also serves as the basis of a project (Endure) that has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant Agreement No. 101000396). The authors would also like to express their gratitude to the Levantina, Ingeniería y Construcción S.L. (LIC) company for funding the construction of the building, and to the Generalitat Valenciana/Fons Social Europeu [APOSTD/2019/101], grant IJC2020-042642-I funded by MCIN/AEI/10.13039/501100011033 and by European Union NextGeneration EU/PRTR, and Universitat Politècnica de València [PAID-10-17] for funding received under different postdoctoral programs.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Dynamic punching assesment of edge columns after sudden corner column removal

  • Garzon-Roca, Julio
  • Sagaseta, Juan
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
[EN] A dynamic punching shear model is presented for general sudden column removal cases which was validated against data from a purpose-built full-scale two-storey reinforced concrete building subjected to a sudden corner column removal. Such analyses are generally performed in structural robustness or integrity design against progressive collapse and several simplifications are generally adopted to avoid complex dynamic nonlinear analyses. These simplifications are generally on the conservative side and punching can be predicted incorrectly. The test results presented showed that Vierendeel action at small deformations was predominant after column removal. The dynamic amplification of the deformations and shear was significant although punching did not occur as predicted by the model. It was found that in general cases punching around edge columns after sudden corner column removal was not critical using design accidental load combinations, although a dynamic punching check is still needed especially for higher live loads and low flexural and punching reinforcement ratios., This work is part of the project funded by the Engineering Physical Science Research Council (EPSRC) of the UK as part of an Impact Acceleration Account (IAA) hold at University of Surrey (EP/K008153/1), and a continuation of two research projects also funded by EPSRC (grant ref:EP/K503939 and EP/K008153/1). The authors would like to acknowledge collaborators at Skidmore, Owings and Merrill (Europe) LLP (D. Jajich and K. Micallef) and also express their gratitude to the Generalitat Valenciana/Fons Social Europeu [APOSTD/2019/101] for the funding received. The experiment was funded by a 2017 Leonardo Grant for Researchers and Cultural Creators from the BBVA Foundation
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Robustness of RC building structures with infill masonry walls: tests on a purpose-built structure

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Calderón García, Pedro Antonio|||0000-0002-9783-9333
  • Adam, Jose M|||0000-0002-9205-8458
  • Bertolesi, Elisa
  • Juan Sagaseta
[EN] Structural robustness is a significant property towards improving resilience of buildings, i.e. enhance their ability to withstand and recover from extreme events which often can cause local damage and progressive collapse. It is widely accepted that robustness depends on the capacity of the structure to activate alternative load paths (ALPs) after the failure of load-bearing elements, e.g. columns. Early evidence during World War II showed that progressive collapse of some buildings was avoided by the presence of masonry infill walls. Subsequent studies focused on this effect for cases of sudden column removal although most of these studies were analytical, numerical and only looked at internal columns which are generally less vulnerable to accidental events compared to corner and edge columns. The aim of this study was to analyse how infill walls can improve the robustness of reinforced concrete (RC) buildings in corner columns failure scenarios. A purpose-built 3D two-storey full-scale RC building structure with infill masonry walls was tested. The contribution of masonry infill walls was analysed in terms of: i) load redistribution, ii) ALPs, and iii) Dynamic Amplification Factors (DAFs) to be applied in linear-static analyses. The test was highly monitored by 38 strain gauges, 38 LVDTs and 2 accelerometers to register the vertical and lateral response. The results showed that masonry infill walls had a significant influence on the structural response and activated the predominant ALPs at very small deflections., This work was carried out with the support of a 2017 Leonardo Grant for Researchers and Cultural Creators from the BBVA Foundation. The authors would also like to express their gratitude to the Levantina, Ingenieria y Construccion S.L. (LIC) company for funding the construction of the building, and to the Generalitat Valenciana/Fons Social Europeu [APOSTD/2019/101] and Universitat Politecnica de Valencia [PAID-10-17] for funding received under different postdoctoral programs.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A Parametric Computational Study of RC Building Structures under Corner-Column Removal Situations

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Adam, Jose M|||0000-0002-9205-8458
  • Bertolesi, Elisa
  • Garzón-Roca, Julio
  • Sagaseta, Juan
[EN] Building progressive collapse is currently one of the hottest topics in the structural engineering field. Most of the research carried out to date on this topic has been focused on the structural analysis of the failure of one or more columns in a building to determine the Alternative Load Paths (ALPs) the structure can activate. Past research was mainly focused on extreme situations with high loads and large structural deformations and, to a lesser extent, research looked at lower loads used in design accidental situations, which requires a different set of assumptions in the analysis. This paper describes a study aimed at analysing accidental design situations in corner-column removal scenarios in reinforced concrete (RC) building structures and evaluating the available real ALPs in order to establish practical recommendations for design situations that could be taken into account in future design codes. A wide parametric computational analysis was carried out with advanced Finite Element (FE) models which the authors validated by full¿scale tests on a purpose¿built building structure. The findings allowed us to: (i) establish design recommendations, (ii) demonstrate the importance of Vierendeel action and (iii) recommend Dynamic Amplification Factors (DAFs) for design situations., This research was funded by Fundacion BBVA-Becas Leonardo a Investigadores y Creadores Culturales 2017; the Spanish Ministry of Economy, Industry and Competitiveness, grant number BIA2017-88322-R-AR; Generalitat Valenciana/Fons Social Europeu, grant number APOSTD/2019/101 and Universitat Politecnica de Valencia, grant number PAID-10-17. This work is also part of the project "Extension of theoretical models against progressive collapse for tall and supertall concrete buildings", funded by the Engineering Physical Science Research Council (EPSRC) of the UK as part of an Impact Acceleration Account (IAA) held at the University of Surrey (grant number EP/K008153/1), and a continuation of two research projects also funded by EPSRC of the UK (grant ref: EP/K503939 and grant ref: EP/K008153/1).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Robustness of a full-scale precast building structure subjected to corner-column failure

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Moragues, Juan J|||0000-0001-8111-5480
  • Adam, Jose M|||0000-0002-9205-8458
  • Sagaseta, Juan
[EN] Although many analytical and experimental studies have been carried out to date on the progressive collapse and robustness of cast-in-place reinforced concrete (RC) and steel building structures, very few experimental research works have been performed on precast concrete (PC) structures. The small number of publications on these experiments have focused on analysing the behaviour of subassemblies after the sudden loss of an internal column. This paper is the first to describe the construction of a full-scale purpose-built experimental PC building to study the sudden removal of corner columns and the structure¿s ability to find alternative load paths (ALPs). The connections between the precast members were designed using existing simplified guidance for robustness. The results obtained from the test using gravity loads corresponding to typical load combinations defined in building codes for accidental design situations, showed a structural response governed by Vierendeel action with a clear contribution from the floor slabs. Load increase factors were obtained from the test results which can be applied by practitioners using simplified linear finite element models to account for non-linear dynamic effects in a simplified manner. This work is expected to form part of a large database of experimental results that are useful for developing advanced numerical simulations and parametric analyses., The authors wish to acknowledge the grant awarded for the PRE-BUST project (ref: BIA2017-88322-R-AR) funded by MCIN/AEI/10.13039/501100011033 and " ERDF A Way of Making Europe " . The authors would also like to express their gratitude for funding received under the postdoctoral programs of the Generalitat Valenciana/Fons Social Europeu [APOSTD/2019/101] and Grant IJC2020-042642-I funded by MCIN/AEI/10.13039/501100011033 and by the " European Union NextGenerationEU/PRTR " . We are also grateful for the invalu- able cooperation of the company Levantina, Ingeniena y Construccion S.L. (LIC) and the contribution of the members and collaborators of the Building Resilient research group (Pedro A. Calderon, Daniel Tasquer, Ghobad Shahnazi, Ana Sanchez, Lorenzo Marin, Giacomo Caredda, Diego F. Cetina, Maria L. Gerbaudo, Marina Oliver) . We would like to give special thanks to Eduardo J. Mezquida-Alcaraz for his work in preparing and carrying out the test.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Robustness of a full-scale precast building structure after edge column failure

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Setiawan, Andri
  • Adam, Jose M|||0000-0002-9205-8458
  • Sagaseta, Juan
[EN] A full-scale purposely built precast concrete building, designed to comply with robustness requirements in current building codes, was subjected to two different scenarios of sudden edge-column removal under the accidental load combination established by the codes. The main aim of this study was to assess how the structural system can prevent collapse initiation after the removal of a single edge column at different locations. This building was later subjected to a larger initial failure with the aim of arresting collapse propagation as part of another piece of research and outside the scope of this specific study. The building was highly instrumented providing unique data at a building system level for the understanding of the development of alternative load paths after the column removals. This work is novel since existing tests of edge-column removal from precast systems correspond mostly to simplified beam-column-slab subassemblies where the interaction with the rest of the building is neglected. The results obtained from this work are particularly relevant towards understanding the role of tying systems used in precast concrete buildings under different accidental scenarios using typical load combinations defined in building codes. The structure was able to redistribute the loads after each column was removed due to a combination of Vierendeel and compressive arching and membrane actions, leading to very small deflections. The role of vertical, horizontal, and floor tying systems in providing continuity between prefabricated and hybrid members was analysed in view of the experimental results obtained. The response obtained differed significantly from design assumptions commonly adopted for tying systems that rely on tensile catenary action at large deflections. This research is timely considering the push to adopt prefabricated components in building construction driven by Net Zero targets while maximising robustness of buildings subjected to more extreme events exacerbated by climate change., The authors wish to acknowledge the funding received by Grant BIA2017-88322-R-AR funded by MCIN/AEI/10.13039/501100011033 and "ERDF A Way of Making Europe", and by a project (Endure) that has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant agreement No. 101000396) . The authors would also like to ex-press their gratitude for funding received under the postdoctoral programs of the Generalitat Valenciana/Fons Social Europeu [APOSTD/2019/101] and Grant IJC2020-042642-I funded by MCIN/AEI/10.13039/501100011033 and by the "European Union NextGener-ationEU/PRTR". We are also grateful for the invaluable cooperation of the company Levantina, Ingenieria y Construccion S.L. (LIC) and the contribution of the members and collaborators of the ICITECH research group.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Robustez de estructuras prefabricadas de hormigón: simulación computacional mediante applied element method

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
  • Adam, Jose M|||0000-0002-9205-8458
  • Mezquida-Alcaraz, Eduardo J.
[ES] El colapso progresivo puede definirse como el proceso por el cual un daño local inicial pone en marcha una cadena de fallos, que a veces puede conducir a un colapso desproporcionado o total. Se trata de un fenómeno que a menudo puede ser desencadenado por cargas anormales causadas por eventos extremos, a los que pueden estar expuestos todo tipo de edificios. A pesar de que las estructuras prefabricadas de hormigón, cada vez más utilizadas, pueden ser especialmente vulnerables al colapso progresivo, se han realizado relativamente pocos estudios sobre la robustez de esta tipología estructural en comparación con las estructuras hormigonadas in situ. Los modelos computacionales validados a partir de resultados experimentales son una de las herramientas más prometedoras para comprender mejor la respuesta de las estructuras prefabricadas de hormigón frente a acciones accidentales. Este trabajo presenta el empleo de una nueva estrategia de modelización, el Applied Element Method, que se ha empleado para predecir el comportamiento de un edificio-probeta de hormigón prefabricado bajo diferentes escenarios de retirada de columnas. Estos resultados se han utilizado para planificar la estrategia de monitorización y el esquema de carga para las pruebas experimentales en una estructura real de dos plantas de 15 m x 12 m que se construirá y monitorizará durante la retirada repentina de tres columnas diferentes., El trabajo presentado en este artículo no habría sido posible sin la financiación recibida del Ministerio de Ciencia e Innovación para el proyecto PREBUST (BIA2017-88322-R-AR) y para la ayuda Juan de la Cierva-Incorporación (IJC2020-042642-I). Los autores desean agradecer a Pedro A. Calderón y Juan J. Moragues su inestimable ayuda y apoyo. También se agradece a Ayman El-Fouly, de Applied Science International, su inestimable colaboración.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Colapso progresivo y robustez de edificios y puentes, Progressive collapse and robustness of buildings and bridges

  • Adam, Jose M|||0000-0002-9205-8458
  • Buitrago, Manuel|||0000-0002-5561-5104
  • Makoond, Nirvan Chandra|||0000-0002-5203-6318
[ES] Los últimos años han estado marcados por un número cada vez más elevado de estudios sobre el colapso progresivo y la robustez estructural como consecuencia de la persistente aparición y aparentemente creciente frecuencia de fallos estructurales catastróficos. En la actualidad, la gran mayoría de estos estudios se centran en simulaciones computacionales y en pruebas de laboratorio de subestructuras a escala reducida. Aunque esta filosofía de estudio ha permitido avanzar sustancialmente en la materia, estas estrategias se caracterizan por sus importantes limitaciones, que sólo pueden superarse mediante ensayos a escala real de las estructuras. Este artículo presenta algunos de los principales trabajos de investigación realizados en este sentido por el grupo de investigación Building Resilient del instituto ICITECH de la Universitat Politècnica de València. Se presentan los trabajos más importantes relacionados con el cimbrado de edificios, las estructuras de edificios de hormigón armado ejecutadas in situ y prefabricadas, los puentes metálicos en celosía y los edificios segmentados por fusibles, junto con los resultados más significativos obtenidos hasta el momento., Estos trabajos no hubieran dado sus frutos sin la financiación y ayuda recibidas por: FGV (Ferrocarrils de la Generalitat Valenciana), Calsens, Ministerio de Ciencia e Innovación, Generalitat Valenciana, Ministerio de Educación y Formación Profesional, Fundación BBVA, European Research Council, LIC Levantina, Ingeniería y Construcción, y Encofrados Alsina.
RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Influence of infill masonry walls in RC building structures under cornercolumn failure scenarios

  • Buitrago, Manuel
  • Bertolesi, Elisa
  • Calderón, Pedro A.
  • Moragues, Juan J.
  • Adam, Jose M.
Extreme events may cause local damage to building structures, and this can be most serious when one or more columns fail. Several studies were carried out for the failure of interior or end columns. The major advances in this direction come from numerical studies and testing of scaled substructures. However, some of the alternative load paths can not be evaluated by testing substructures. In this study, a complete and real-scale RC building structure was carried out by ICITECH of the Universitat Politècnica de València to assess its progressive collapse behaviour under corner-column failure scenarios without and with the consideration of infill masonry walls. Before testing, as a reference for the experimental tests, a finite element model was developed in ABAQUS considering a dynamic analysis and material and geometrical non-linearities. This paper analyses the results predicted by the numerical simulation: alternative load paths, displacements and damage of the RC structure.