DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication
Artículo científico (JournalArticle)
Online oxygen monitoring using integrated inkjet-printed sensors in a liver-on-a-chip system
The demand for real-time monitoring of cell functions and cell conditions has dramatically increased with the emergence of organ-on-a-chip (OOC) systems. However, the incorporation of co-cultures and microfluidic channels in OOC systems increases their biological complexity and therefore makes the analysis and monitoring of analytical parameters inside the device more difficult. In this work, we present an approach to integrate multiple sensors in an extremely thin, porous and delicate membrane inside a liver-on-a-chip device. Specifically, three electrochemical dissolved oxygen (DO) sensors were inkjet-printed along the microfluidic channel allowing local online monitoring of oxygen concentrations. This approach demonstrates the existence of an oxygen gradient up to 17.5% for rat hepatocytes and 32.5% for human hepatocytes along the bottom channel. Such gradients are considered crucial for the appearance of zonation of the liver. Inkjet printing (IJP) was the selected technology as it allows drop on demand material deposition compatible with delicate substrates, as used in this study, which cannot withstand temperatures higher than 130 °C. For the deposition of uniform gold and silver conductive inks on the porous membrane, a primer layer using SU-8 dielectric material was used to seal the porosity of the membrane at defined areas, with the aim of building a uniform sensor device. As a proof-of-concept, experiments with cell cultures of primary human and rat hepatocytes were performed, and oxygen consumption rate was stimulated with carbonyl-cyanide-4-(trifluoromethoxy)phenylhydrazone (FCCP), accelerating the basal respiration of 0.23 ± 0.07 nmol s-1/106 cells up to 5.95 ± 0.67 nmol s-1/106 cells s for rat cells and the basal respiration of 0.17 ± 0.10 nmol s-1/106 cells by up to 10.62 ± 1.15 nmol s-1/106 cells for human cells, with higher oxygen consumption of the cells seeded at the outflow zone. These results demonstrate that the approach of printing sensors inside an OOC has tremendous potential because IJP is a feasible technique for the integration of different sensors for evaluating metabolic activity of cells, and overcomes one of the major challenges still remaining on how to tap the full potential of OOC systems., This work was supported by the Spanish government funded project DPI2015-65401-C3-3-R (MINECO/FEDER, EU), by the Explora projects SAF2014-62114-EXP and BIO2014-61377-EXP and by a PIE-201450E116 funded by CSIC. We thank Emman-uel Stratakis from the Foundation for Research and Technology – Hellas for his tests to seal the PTFE membranes with laser technology. We also thanks Ignacio Giménez from IACS (Universidad de Zaragoza) for their support in the analysis of the biological results. The authors also acknowledge ICTS “NANBIOSIS”, more specifically by the SU-8 Unit of the CIBER in Bioengineering, Biomaterials & Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC). This work has also made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM. Part of this work was performed at the Centre Esther Koplowitz (CEK) – IDIBAPS, Barcelona., Peer reviewed
Project:
MINECO / FP7 BIO2014-61377-EXP
,
EC PIE-201450E116
,
MINECO DPI2015-65401-C3-3-R
,
MINECO SAF2014-62114-EXP
DOI: http://hdl.handle.net/10261/377541, https://api.elsevier.com/content/abstract/scopus_id/85049910417
HANDLE: http://hdl.handle.net/10261/377541, https://api.elsevier.com/content/abstract/scopus_id/85049910417