MICROSENSORES INTEGRADOS EN MEMBRANAS DE CULTIVO CELULAR DESARROLLADOS POR INKJET PRINTING

DPI2015-65401-C3-3-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2015
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Dirección General de Investigación Científica y Técnica
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Miniaturized multiparametric flexible platform for the simultaneous monitoring of ionic: Application in real urine

  • Moya, A.
  • Illa, Xavi
  • Gimenez, I.
  • Lazo-Fernandez, Y.
  • Villa, Rosa
  • Errachid, Abdelhamid
  • Gabriel, G.
Biomonitoring is a research topic that has largely relied on cell culture systems. Recently, the development of “Organ-on-a-Chip” (OC) platforms and the need for a continuous monitoring of these systems has increased its interest. However, the biomonitorization in these systems is still at its infancy due to the difficulty to adapt the sensors to microfluidic OC systems. In this work we have fabricated a modular, versatile, scalable, multi-analyte sensing platform, which integrates dissolved oxygen (DO), Na, K and pH sensors for monitoring their concentrations in small volume of biological fluids. The platform is fabricated by means of rapid prototyping techniques using polymeric substrates, and incorporates all the necessary elements to measure the four analytes. It was designed with four gold sensing electrodes, and integrates a gold counter electrode and an Ag/AgCl pseudo-reference electrode for the electrochemical measurements in small volumes (0.83 μL) of samples. The sensors featured good sensitivities of 3.60 ± 0.2 nA (mg L) for DO and 69 ± 1 mV decade for pH. Na and K μISE exhibited sensitivities of 57 ± 1 mV decade and 52 ± 2 mV decade, and low limits of detection 5 × 10 M and 0.5 × 10 M respectively. This platform allows the dynamic measurement of the biological fluids parameters simultaneously, in real time and with a rapid response. The versatility of the platform allows its adaptation in any microfluidic cells culture systems. The novel multi-sensor platform has been validated in controlled buffers and with artificial urine (AU). A proof-of-concept using real mice urine (RU) has been carried out, demonstrating the good behaviour of the multi-sensing platform., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Geometric correction factor for transepithelial electrical resistance measurements in transwell and microfluidic cell cultures

  • Yeste Lozano, José
  • Illa, Xavi
  • Gutiérrez, Cristina
  • Solé, Montse
  • Guimerà-Brunet, Anton
  • Villa, Rosa
Transepithelial electrical resistance (TEER) measurements are regularly used in in vitro models to quantitatively evaluate the cell barrier function. Although it would be expected that TEER values obtained with the same cell type and experimental setup were comparable, values reported in the literature show a large dispersion for unclear reasons. This work highlights a possible error in a widely used formula to calculate the TEER, in which it may be erroneously assumed that the entire cell culture area contributes equally to the measurement. In this study, we have numerically calculated this error in some cell cultures previously reported. In particular, we evidence that some TEER measurements resulted in errors when measuring low TEERs, especially when using Transwell inserts 12 mm in diameter or microfluidic systems that have small chamber heights. To correct this error, we propose the use of a geometric correction factor (GCF) for calculating the TEER. In addition, we describe a simple method to determine the GCF of a particular measurement system, so that it can be applied retrospectively. We have also experimentally validated an interdigitated electrodes (IDE) configuration where the entire cell culture area contributes equally to the measurement, and it also implements minimal electrode coverage so that the cells can be visualized alongside TEER analysis., This work is part of the requirements to achieve the PhD degree in Electrical and Telecommunication Engineering at the Universitat Autònoma de Barcelona and it was supported by grants from CIBER-BBN, CSIC (PIE-201450E116) and Ministerio de Economía y Competitividad (SAF2014-62114-EXP and DPI2015-65401-C3-3-R). CIBER-BBN is funded by Instituto de Salud Carlos III. We are grateful to Drs. Pierre-Olivier Couraud (INSERM, France), Babette Weksler (Weill Cornell Medical College, New York, NY) and Ignacio Romero (Open University, Milton Keynes, UK) for kindly providing the hCMEC/D3 cell line. We would also acknowledge to Dr Mercedes Unzeta (Universitat Autònoma de Barcelona, Spain) for her advice and providing materials to perform the experiments with the cells., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A perfusion chamber for monitoring transepithelial NaCl transport in an in vitro model of the renal tubule

  • Yeste Lozano, José
  • Martínez Gimeno, Laura
  • Illa, Xavi
  • Laborda, Pablo
  • Guimerà-Brunet, Anton
  • Sánchez Marín, Juan P
  • Villa, Rosa
  • Giménez, Ignacio
Transepithelial electrical measurements in the renal tubule have provided a better understanding of how kidney regulates electrolyte and water homeostasis through the reabsorption of molecules and ions (e.g., H2O and NaCl). While experiments and measurement techniques using native tissue are difficult to prepare and to reproduce, cell cultures conducted largely with the Ussing chamber lack the effect of fluid shear stress which is a key physiological stimulus in the renal tubule. To overcome these limitations, we present a modular perfusion chamber for long-term culture of renal epithelial cells under flow that allows the continuous and simultaneous monitoring of both transepithelial electrical parameters and transepithelial NaCl transport. The latter is obtained from electrical conductivity measurements since Na+ and Cl- are the ions that contribute most to the electrical conductivity of a standard physiological solution. The system was validated with epithelial monolayers of raTAL and NRK-52E cells that were characterized electrophysiologically for 5 days under different flow conditions (i.e., apical perfusion, basal, or both). In addition, apical to basal chemical gradients of NaCl (140/70 and 70/140 mM) were imposed in order to demonstrate the feasibility of this methodology for quantifying and monitoring in real time the transepithelial reabsorption of NaCl, which is a primary function of the renal tubule., This work is part of the requirements to achieve the PhD degree in Electrical and Telecommunication Engineering at the Universitat Autònoma de Barcelona, and it was supported by grants from Ministerio de Economía y Competitividad (MINECO) (SAF2014-62114-EXP, DPI2015-65401-C3-3-R, and DPI2011-28262-C04-02). This work has made use of the Spanish ICTS Network MICRONANOFABS partially supported by MINECO and the ICTS 'NANBIOSIS', more specifically by the Micro-Nano Technology Unit of the CIBER in Bioengineering, Biomaterials & Nanomedicne (CIBER-BBN) at the IMB-CNM., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Engineering and monitoring cellular barrier models

  • Yeste Lozano, José
  • Illa, Xavi
  • Álvarez, Mar
  • Villa, Rosa
Epithelia and endothelia delineate tissue compartments and control their environments by regulating the passage of ions and solutes. This barrier function is essential for the development and maintenance of multicellular organisms, and its dysfunction is associated with numerous human diseases. Recent advances in biomaterials and microfabrication technologies have evolved in vitro approaches for modelling biological barriers. Current microphysiological systems have become more efficient and reliable in mimicking the cell microenvironment. Additionally, methods for the quantification of barrier permeability have long provided significant insight into their underlying mechanisms. In this review, we outline the current techniques to quantify the barrier function of engineered tissues, and we also give an overview of recent microphysiological systems of biological barriers that emulate the microenvironment and microarchitecture of native tissues., This work has been supported by grants from the Ministerio de Economía y Competitividad (MINECO) (SAF2014–62114-EXP, DPI2015–65401-C3–3-R, and RYC-2013-14479) and from CIBER in Bioengineering, Biomaterials & Nanomedicine (CIBER-BBN)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Online oxygen monitoring using integrated inkjet-printed sensors in a liver-on-a-chip system

  • Moya, Ana
  • Ortega-Ribera, M
  • Guimerà, X
  • Sowade, E
  • Zea, Miguel
  • Illa, Xavi
  • Ramon, Eloi
  • Villa, Rosa
  • Gracia-Sancho, J
  • Gabriel, Gemma
The demand for real-time monitoring of cell functions and cell conditions has dramatically increased with the emergence of organ-on-a-chip (OOC) systems. However, the incorporation of co-cultures and microfluidic channels in OOC systems increases their biological complexity and therefore makes the analysis and monitoring of analytical parameters inside the device more difficult. In this work, we present an approach to integrate multiple sensors in an extremely thin, porous and delicate membrane inside a liver-on-a-chip device. Specifically, three electrochemical dissolved oxygen (DO) sensors were inkjet-printed along the microfluidic channel allowing local online monitoring of oxygen concentrations. This approach demonstrates the existence of an oxygen gradient up to 17.5% for rat hepatocytes and 32.5% for human hepatocytes along the bottom channel. Such gradients are considered crucial for the appearance of zonation of the liver. Inkjet printing (IJP) was the selected technology as it allows drop on demand material deposition compatible with delicate substrates, as used in this study, which cannot withstand temperatures higher than 130 °C. For the deposition of uniform gold and silver conductive inks on the porous membrane, a primer layer using SU-8 dielectric material was used to seal the porosity of the membrane at defined areas, with the aim of building a uniform sensor device. As a proof-of-concept, experiments with cell cultures of primary human and rat hepatocytes were performed, and oxygen consumption rate was stimulated with carbonyl-cyanide-4-(trifluoromethoxy)phenylhydrazone (FCCP), accelerating the basal respiration of 0.23 ± 0.07 nmol s-1/106 cells up to 5.95 ± 0.67 nmol s-1/106 cells s for rat cells and the basal respiration of 0.17 ± 0.10 nmol s-1/106 cells by up to 10.62 ± 1.15 nmol s-1/106 cells for human cells, with higher oxygen consumption of the cells seeded at the outflow zone. These results demonstrate that the approach of printing sensors inside an OOC has tremendous potential because IJP is a feasible technique for the integration of different sensors for evaluating metabolic activity of cells, and overcomes one of the major challenges still remaining on how to tap the full potential of OOC systems., This work was supported by the Spanish government funded project DPI2015-65401-C3-3-R (MINECO/FEDER, EU), by the Explora projects SAF2014-62114-EXP and BIO2014-61377-EXP and by a PIE-201450E116 funded by CSIC. We thank Emman-uel Stratakis from the Foundation for Research and Technology – Hellas for his tests to seal the PTFE membranes with laser technology. We also thanks Ignacio Giménez from IACS (Universidad de Zaragoza) for their support in the analysis of the biological results. The authors also acknowledge ICTS “NANBIOSIS”, more specifically by the SU-8 Unit of the CIBER in Bioengineering, Biomaterials & Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC). This work has also made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM. Part of this work was performed at the Centre Esther Koplowitz (CEK) – IDIBAPS, Barcelona., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

All-inkjet-printed dissolved oxygen sensors on flexible plastic substrates

  • Moya, Ana
  • Sowade, Enrico
  • del Campo, Francisco J.
  • Mitra, Kalyan Y.
  • Ramon, Eloi
  • Villa, Rosa
  • Baumann, Reinhard R.
  • Gabriel, Gemma
Inkjet printing is a promising alternative manufacturing method to conventional standard microfabrication techniques for the development of flexible and low-cost devices. Although the use of inkjet printing for the deposition of selected materials for the development of sensor devices has been reported many times in literature, it is still a challenge and a potential route towards commercialization to completely manufacture sensor devices with inkjet technology. In this work is demonstrated the fabrication of a functional low-cost dissolved oxygen (DO) amperometric sensor with feature sizes in the micrometer range using inkjet printing. All the required technological steps for the fabrication of a complete electrochemical three electrodes system are discussed in detail. The working and counter electrodes have been printed using a gold nanoparticle ink, whereas a silver nanoparticle ink was used to print a pseudo-reference electrode. Both inks are commercially available and can be sintered at low temperatures, starting already at 120 °C, which allows the use of plastic substrates. In addition, a printable SU8 ink formulation cured by UV is applied as passivation layer in the sensor device. Finally, as the performance of analytical methods strongly depends on the working electrode material, is demonstrated the electrochemical feasibility of this printed DO sensor, which shows a linear response in the range between 0 and 8 mg L<sup>−1</sup> of DO, and affords a detection limit of 0.11 mg L<sup>−1</sup>, and a sensitivity of 0.03 μA L mg<sup>−1</sup>. The use of flexible plastic substrates and biocompatible inks, and the rapid prototyping and low-cost of the fabricated sensors, makes that the proposed manufacturing approach opens new opportunities in the field of biological and medical sensor applications., This work was supported by the Ministerio de Economía y Competitividad [CTQ2015-69802-C2-1-R and DPI2015-65401-C3-3-R]; and the Generalitat de Catalunya [2014SGR1452]. The authors kindly acknowledge Christoph Sternkiker (TU Chemnitz, Digital Printing and Imaging Technology) for his support with inkjet printing and measuring of surface energy. A.M. gratefully acknowledges her FPI-2012 pre-doctoral scholarship, (it funded her PhD studies at Universitat Autònoma de Barcelona) and the mobility aid [EEBB-I-15-09362], (it financed her four-months stay at the TU Chemnitz, Department of Digital Printing and Imaging Technology) both granted by the Ministerio de Economía y Competitividad (Spain). The authors also acknowledge ICTS “NANBIOSIS”, more specifically by the SU8 Unit of the CIBER in Bioengineering, Biomaterials & Nanomedicne (CIBER-BBN) at the IMB-CNM (CSIC)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Inkjet-printed electrochemical sensors

  • Moya, Ana
  • Gabriel, Gemma
  • Villa, Rosa
  • Javier del Campo, F.
Inkjet printing is a digital and non-contact printing technique that is beginning to be used in the manufacture of electronic devices, including electrochemical sensors. This article covers the main works featuring inkjet printing for the production of electrochemical sensors, and focuses especially on the works reported since 2015. The main factor limiting the application of inkjet printing in the manufacture of advanced devices stems mainly from the strict rheological conditions that the ink needs to meet. This is the reason why inkjet is best used in combination with other manufacturing techniques. Given their high degree of maturity and accessibility, home/office printers will likely lead a future wave in the manufacture of electronic devices, particularly at the development and prototyping stages., The authors would like to acknowledge funding from the Spanish Ministry of Economy and Competitiveness through project grants CTQ2015-69802-C2-1-R, CTQ2015-69802-C2-1-R, and DPI2015-65401-C3-3-R MINECO/FEDER, EU. JdC acknowledges a grant for Researchers and Cultural Creators (2016) from the BBVA Foundation. The authors are grateful to Mr. Ignasi Riera, from INKZAR S.L., for fruitful discussions., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Inkjet printed flexible non-enzymatic glucose sensor for tear fluid analysis

  • Romeo, Agostino
  • Moya, Ana
  • Leung, Tammy S.
  • Gabriel, Gemma
  • Villa, Rosa
  • Sánchez, Samuel
Here, we present a flexible and low-cost inkjet printed electrochemical sensor for enzyme-free glucose analysis. Versatility, short fabrication time and low cost make inkjet printing a valuable alternative to traditional sensor manufacturing techniques. We fabricated electro-chemical glucose sensors by inkjet printing electrodes on a flexible polyethylene terephthalate substrate. CuO microparticles were used to modify our electrodes, leading to a sensitive, stable and cost-effective platform for non-enzymatic detection of glucose. Selectivity, reproducibility, and life-time provided by the CuO functionalization demonstrated that these sensors are reliable tools for personalized diagnostics and self-assessment of an individual's health. The detection of glucose at concentrations matching that of tear fluid allows us to envisage applications in ocular diagnostics, where painless and non-invasive monitoring of diabetes can be achieved by analyzing glucose contained in tears., This work was supported by the European Research Council (ERC) Starting Grant “Lab-in-a-tube and Nano-robotics biosen-sors; LT-NRBS” [no. 311529] and Spanish Ministry of Economy and Competitiveness through project grant DPI2015-65401-C3-3-R MINECO/FEDER, EU. A.R. acknowledges financial support pro- vided by the European Commission under Horizon 2020’s Marie Skłodowska-Curie Actions COFUND scheme [Grant Agreement no. 712754] and by the Severo Ochoa programme of the Spanish Ministry of Economy and Competitiveness [Grant SEV-2014-0425 (2015–2019)]. G.G. and A.M. acknowledge ICTS “NANBIOSIS”, more specifically the SU8 Unit of the CIBER in Bioengineering, Biomaterials & Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC). This work has also made use of the Spanish ICTS Network MICRONANOFABS partially supported by MEINCOM. The authors would like to thank Mrs. Felicitas Pradel for SEM-EDX investigations., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Enhanced Performance Stability of Iridium Oxide-Based pH Sensors Fabricated on Rough Inkjet-Printed Platinum

  • Zea, Miguel
  • Moya, Ana
  • Fritsch, Marco
  • Ramon, Eloi
  • Villa, Rosa
  • Gabriel, Gemma
Today, electrochemical sensors are used for a broad range of applications. A fundamental challenge is still the achievement of long-term sensor stability by ensuring good adhesion between the deposited sensing layer and the substrate material, e.g., a metal electrode. Until now, the most applied strategy to overcome this problem is to increase the surface roughness of the metal layer by mechanical etching or by electroplating of additional material layers, which both imply an increase in manufacturing steps and thus the final cost of the overall device. Alternatively, to overcome these adhesion problems, we propose the direct printing of a novel platinum nanoparticle ink, which is compatible with low-cost additive digital inkjet and with flexible low-cost substrates. This water-based platinum ink has two unique features: it leads to highly rough surfaces, which promotes the adhesion of deposited sensing material, and it is a highly low-temperature curing ink, compatible with polymeric substrates that cannot withstand high temperatures. Based on this concept, we report about a long-term stable and highly sensitive solid-state pH sensor functionalized by anodic electrodeposited iridium oxide on a rough nanostructured platinum printed layer. The sensors showed an excellent reproducibility with a linear super-Nernstian response (71.3 ± 0.3 mV/pH unit) in a wide pH range (pH 2-11). Long-term stability tests for over 1 year of application demonstrate an excellent mechanical sensor layer stability, which is correlated to the distinct roughness of the printed platinum layer. This novel approach is useful to simplify the fabrication process and with that the sensor costs., M.Z. acknowledges financial support covered by Fundación Centro de Estudios Interdisciplinarios Bá sicos y Aplicados (CEIBA)-Gobernacion de Bolivar (Colombia). This work was supported by the Spanish government funded project by Ministerio de Economí a y Competitividad CTQ2015-69802-C2-1-R (MINECO/FEDER, EU) and DPI2015-65401-C3-3-R (MINECO/FEDER, EU). Authors also want to thank the support of the Generalitat de Catalunya to 2017-SGR-988, and the SU-8 Unit of the CIBER in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN) at the IMB-CNM (CSIC) of ICTS “NANBIOSIS”. This work has also made use of the Spanish ICTS Network MICRONANOFABS partially sup-ported by MEINCOM, Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A perfusion chamber for monitoring transepithelial NaCl transport in an in vitro model of the renal tubule

  • Yeste, J.
  • Martínez-Gimeno, L.
  • Illa, X.
  • Laborda, P.
  • Guimerà, A.
  • Sánchez-Marín, J.P.
  • Villa, R.
  • Giménez, I.
Transepithelial electrical measurements in the renal tubule have provided a better understanding of how kidney regulates electrolyte and water homeostasis through the reabsorption of molecules and ions (e.g., H2O and NaCl). While experiments and measurement techniques using native tissue are difficult to prepare and to reproduce, cell cultures conducted largely with the Ussing chamber lack the effect of fluid shear stress which is a key physiological stimulus in the renal tubule. To overcome these limitations, we present a modular perfusion chamber for long-term culture of renal epithelial cells under flow that allows the continuous and simultaneous monitoring of both transepithelial electrical parameters and transepithelial NaCl transport. The latter is obtained from electrical conductivity measurements since Na+ and Cl- are the ions that contribute most to the electrical conductivity of a standard physiological solution. The system was validated with epithelial monolayers of raTAL and NRK-52E cells that were characterized electrophysiologically for 5 days under different flow conditions (i.e., apical perfusion, basal, or both). In addition, apical to basal chemical gradients of NaCl (140/70 and 70/140 mM) were imposed in order to demonstrate the feasibility of this methodology for quantifying and monitoring in real time the transepithelial reabsorption of NaCl, which is a primary function of the renal tubule.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Miniaturized multiparametric flexible platform for the simultaneous monitoring of ionic: Application in real urine

  • Moya, Ana
  • Illa, Xavi
  • Giménez, Ignacio
  • Lazo-Fernández, Yoskaly
  • Villa, Rosa
  • Errachid, Abdelhamid
  • Gabriel, Gemma
Biomonitoring is a research topic that has largely relied on cell culture systems. Recently, the development of “Organ-on-a-Chip” (OC) platforms and the need for a continuous monitoring of these systems has increased its interest. However, the biomonitorization in these systems is still at its infancy due to the difficulty to adapt the sensors to microfluidic OC systems. In this work we have fabricated a modular, versatile, scalable, multi-analyte sensing platform, which integrates dissolved oxygen (DO), Na+, K+ and pH sensors for monitoring their concentrations in small volume of biological fluids. The platform is fabricated by means of rapid prototyping techniques using polymeric substrates, and incorporates all the necessary elements to measure the four analytes. It was designed with four gold sensing electrodes, and integrates a gold counter electrode and an Ag/AgCl pseudo-reference electrode for the electrochemical measurements in small volumes (0.83 µL) of samples. The sensors featured good sensitivities of 3.60 ± 0.2 nA (mg L-1) for DO and 69 ± 1 mV decade-1 for pH. Na+ and K+ µISE exhibited sensitivities of 57 ± 1 mV decade-1 and 52 ± 2 mV decade-1, and low limits of detection 5 × 10-6 M and 0.5 × 10-5 M respectively. This platform allows the dynamic measurement of the biological fluids parameters simultaneously, in real time and with a rapid response. The versatility of the platform allows its adaptation in any microfluidic cells culture systems. The novel multi-sensor platform has been validated in controlled buffers and with artificial urine (AU). A proof-of-concept using real mice urine (RU) has been carried out, demonstrating the good behaviour of the multi-sensing platform.