Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Novel nanostructured indium tin oxide electrode for electrochemical immunosensors: Suitability for the detection of TNF-a

  • Pruna I Morales, Raquel
  • Baraket, Abdoullatif
  • Bonhommé, Anne
  • Zine, Nadia
  • Errachid, Abdelhamid
  • López, Manuel
The need for new and innovative point of care (POC) systems providing a feasible alternative to costly and time consuming standard laboratory techniques is becoming more evident every day, particularly in the case of cardiovascular diseases. Coupling optical and electrochemical principles for highly specific and sensitive detection of biomarkers could boost the successful implementation of POC systems in biomedical environments. We suggest indium tin oxide (ITO) as a promising material for working electrodes in optoelectrochemical sensors, owing to the rare combination of high electrical conductivity and optical transparency it presents. Moreover, the nanostructured nature of the electrodes' surface is crucial for an eventual miniaturization of the POC system. In this work, we describe the construction and characterization of a nanostructured ITO electrode modified with aryl diazonium salt as transparent substrate for electrochemical immunosensors. The developed electrode was tested for the detection of tumour necrosis factor alfa (TNF-alfa), a cardiac biomarker playing an important role in the prevention of heart failure. Macro and microscopic evidences (gathered from electrochemical and spectral techniques) of covalent bonding and high surface coverage are provided. Specific interaction between antigen (TNF-alfa) and monoclonal antibody (Ab-TNF-alfa) was verified by fluorescence patterning, confirming the proper bio-recognition of the cytokine. As a proof-of-concept, results of electrochemical impedance spectroscopy (EIS) show stabilized semi-quantitative label-free detection of TNF-alfa at several concentrations (from 10 pg/mL to 100 pg/mL). These preliminary results demonstrate the feasibility of using transparent substrates for the detection of cytokines at low concentrations, and the consequent application in POC systems for the monitoring of cardiovascular diseases., The research leading to these results has received funding from the European Union's 7FP (SEA-on-a-CHIP, Grant Agreement no. 614168) and the European Union's Horizon 2020 (HEARTEN, Grant Agreement no. 643694). R.P. acknowledges an FPU grant from the Spanish Ministerio de Educación, Cultura y Deporte.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

A low-cost and miniaturized potentiostat for the monitoring of immunobiosensors by electrochemical impedance spectroscopy

  • Pruna I Morales, Raquel
  • Palacio, Francisco
  • Baraket, Abdoullatif
  • Zine, Nadia
  • Streklas, Angelos
  • Bausells, Joan
  • Errachid, Abdelhamid
  • López, Manuel
Miniaturizing potentiostats, keeping their cost low and yet preserving full measurement characteristics (e.g. bandwidth, determination of capacitive/inductive contribution to sensor's impedance and parallel screening) is still an unresolved challenge in bioelectronics. In this work, the combination of simple analogue circuitry together with powerful microcontrollers and a digital filter implementation is presented as an alternative to complex and incomplete architectures reported in the literature. A low-cost acquisition electronic system fully integrated with a biosensors platform containing eight gold working microelectrodes and integrated reference and counter electrodes was developed and validated. The manufacturing cost of the prototype was kept below 300 USD. The performance of the proposed device was benchmarked against a commercial impedance analyzer through the electrochemical analysis of a highly sensitive biosensor for the detection of tumor necrosis factor alfa (TNF-alfa) within the randomly chosen range of 266pg/mL to 666ng/mL in physiological medium (PBS). A strong correlation between the outputs of both devices was found in a critical range of frequencies (1-10Hz), and several TNF-alfa cytokine concentrations were properly discriminated. These results are very promising for the development of low-cost, portable and miniaturized electrochemical systems for point-of-care and environmental diagnosis., The research leading to these results has received funding from the European Union's 7FP (SEA-on-a-CHIP, Grant Agreement no. 614168) and the European Union's Horizon 2020 (HEARTEN, Grant Agreement no. 643694). R.P. acknowledges an FPU grant (FPU15/00771) from the Spanish Ministerio de Educación, Cultura y Deporte.
Dipòsit Digital de la UB
Publication Artículo científico (JournalArticle)

Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization

  • Pruna Morales, Raquel
  • Palacio Bonet, Francisco
  • Baraket, Abdoullatif
  • Bausells, Joan
  • Errachid, Abdelhamid
  • López de Miguel, Manuel
The development of miniaturized potentiostats capable of measuring in a wide range of conditions and with full characteristics (e.g., wide bandwidth and capacitive/inductive contribution to sensor's impedance) is still an unresolved challenge in bioelectronics. We present a simple analogue design coupled to a digital filter based on a lock-in amplifier as an alternative to complex architectures reported hitherto. A low-cost, miniaturized and fully integrated acquisition electronic system was developed, tested for a fully integrated three-lead electrochemical biosensor and benchmarked against a commercial potentiostat. The portable potentiostat was coupled to an array of miniaturized gold working electrodes to perform complex impedance analyses for tumor necrosis factor α (TNF-α) cytokine detection. This wearable potentiostat is very promising for the development of low-cost point-of-care (POC) with low power consumption.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Low-Cost Impedance Measurements for Lab-on-a-Chip Architectures: Towards Potentiostat Miniaturization

  • Pruna, Raquel
  • Palacio, Francisco
  • Baraket, Abdellatif
  • Bausells, Joan
  • Errachid, Abdelhamid
  • López, Manel
The development of miniaturized potentiostats capable of measuring in a wide range of conditions and with full characteristics (e.g., wide bandwidth and capacitive/inductive contribution to sensor’s impedance) is still an unresolved challenge in bioelectronics. We present a simple analogue design coupled to a digital filter based on a lock-in amplifier as an alternative to complex architectures reported hitherto. A low-cost, miniaturized and fully integrated acquisition electronic system was developed, tested for a fully integrated three-lead electrochemical biosensor and benchmarked against a commercial potentiostat. The portable potentiostat was coupled to an array of miniaturized gold working electrodes to perform complex impedance analyses for tumor necrosis factor α (TNF-α) cytokine detection. This wearable potentiostat is very promising for the development of low-cost point-of-care (POC) with low power consumption., The research leading to these results has received funding from the European Union’s 7FP (SEA-on-a-CHIP, Grant Agreement No. 614168) and the European Union’s Horizon 2020 (HEARTEN, Grant Agreement No. 643694). R.P. acknowledges an FPU grant from the Spanish Ministerio de Educación, Cultura y Deporte.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A Highly Sensitive Potentiometric Amphetamine Microsensor Based on All-Solid-State Membrane Using a New Ion-Par Complex, [3,3′-Co(1,2-closo-C2B9H11)2]− C9H13NH+

  • Gallardo González, Juan
  • Baraket, Abdellatif
  • Boudjaoui, S.
  • Clément, Y.
  • Alcácer, A.
  • Streklas, A.
  • Teixidor, Francesc
  • Zine, Nadia
  • Bausells, Joan
  • Errachid, Abdelhamid
In the present work a highly sensitive ion-selective microelectrode for the detection of amphetamine is presented. For this purpose, a novel ion-par complex based on the metallocarborane, cobalt bis(dicarbollide) anion ([3,3′-Co(1,2-C<sub>2</sub>B<sub>9</sub>H<sub>11</sub>)<sub>2</sub>]<sup>−</sup>) coupled to amphetamonium cation has been prepared as the active site for amphetamine recognition. The prepared ion-par complex was incorporated to a PVC-type sensitive membrane. It was then drop-casted on the top of a gold microelectrode previously modified with a solid contact layer of polypyrrole. This novel amphetamine microsensor has provided excellent and quick response within the range 10<sup>−5</sup> M to 10<sup>−3</sup> M of amphetamine concentration, a limit of detection of 12 µM and a slope of 60.1 mV/decade. It was also found to be highly selective toward some potential interference compounds when compared to amphetamine., The authors acknowledge the financial support from the European Union’s Horizon 2020 research and innovation programme entitled MicroMole and HEARTEN grant agreement No. 653626 and No. 643694 respectively
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Electrochemical capacitive K+ EMIS chemical sensor based on the dibromoaza[7]helicene as an ionophore for potassium ions detection

  • Tounsi, Moncef
  • Zabala, Miguel
  • Bausells, Joan
  • Errachid, Abdelhamid
Tounsi, Moncef et al., A K+-sensitive capacitive electrolyte-membrane-insulator-semiconductor (EMIS) based on a novel dibromoaza[7]helicene ionophore has been developed. An ion-sensitive membrane based on polyvinylchloride (PVC) doped with the ionophore was deposited on the Si3N4/SiO2/Si-p/Cu-Al transducer. The properties of the K+-EMIS chemical sensor were investigated by electrochemical impedance spectroscopy (EIS). All the developed devices upon being tested have shown good sensitivity and linearity responses within the range 10-6 M to 10-1 M of potassium activity, with good selectivity over a wide variety of other cations (Na+, Li+, Cu2+, Ca2+, and Mg2+). To our knowledge, this is the first time that a capacitive field-effect sensor has been fabricated using helicene as a carrier for a K+-detection, combined with the structure Si3N4/SiO2/Si-p/Cu-Al as a transducer., We acknowledge the funding through the European Communities Seventh Framework Programme entitled Sea-on-a-Chip (FP7-OCEAN-2013) (No.614168), the European Union's Horizon 2020 Research and Innovation Programme entitled HEARTEN under grant agreement No 643694, NATO (CBP.NUKR.SFP 984173), and FP7-PEOPLE-2012-IRSES under the grant agreement No. 318053 (SMARTCANCERSENS). M. T. would like to acknowledge PHC-12 Mag088 project, and the Ministry of Higher Education and Scientific Research of Tunisia (LR11ES55)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Development of a novel capacitance electrochemical biosensor based on silicon nitride for ochratoxin A detection

  • Bougrinia, Madiha
  • Baraket, Abdoullatif
  • Jamshaid, Talha
  • El Aissari, Abdelhamid
  • Bausells, Joan
  • Zabala, Miguel
  • El Bari, Nezha
  • Bouchikhi, Benachir
  • Jaffrezic-Renault, Nicole
  • Errachid, Abdelhamid
  • Zine, Nadia
We report in this paper about the development of a novel capacitance electrochemical biosensor based on silicon nitride substrate (SiN) combined with a new structure of mangnetic nanoparticles (MNPs). SiN is highly stable as it was fabricated by a combination of several layers of Aluminum (Al), silicon p-doped (Si-p), silicon dioxide (SiO) and silicon nitride (SiN). This structure (SiN/SiO/Si-p/Al) has provided several advantages compared with other materials commonly used, and in particular in solid-state physics for electronic-based biosensors. The MNPs with terminated carboxylic acid were covalently bonded to SiN through a Self-Assembled Monolayers (SAMs) of the silane-amine (3-Aminopropyl) triethoxysilane (APTES). Finally anti-ochratoxin A antibodies were immobilized on MNPs by amide bonding. Contact Angle measurements, Atomic Force Microscopy, Scanning Electron Microscopy and Fluorescence Microscopy characterizations were performed during the biofunctionalization of the biosensor surface. Electrochemical measurements were carried out using Mott-Schottky analysis for ochratoxin A detection. The biosensor was highly sensitive and specific for ochratoxin A antigens, with a limit of detection of 4.57 pM, when compared to other interferences ochratoxin B and aflatoxin G1. The measurements were highly stable and reproducible for detection and interferences. The proposed method is very promising for ochratoxin A detection of several agro-food industry applications., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Silicon Nitride Capacitive Chemical Sensor for Phosphate Ion Detection Based on Copper Phthalocyanine – Acrylate-polymer

  • Barhoumi, Lassaad
  • Baraket, Abdoullatif
  • Nooredeen, Naglaa Mohammed
  • Ben Ali, Mounir
  • Nooredeen Abbas, Mohammed
  • Bausells, Joan
  • Errachid, Abdelhamid
In this work, we report the development of a highly sensitive capacitance chemical sensor based on a copper C,C,C,C-tetra-carboxylic phthalocyanine-acrylate polymer adduct (Cu(II)TCPc-PAA) for phosphate ions detection. A capacitance silicon nitride substrate based AlCu/Si-p/SiO2/Si3N4 structure was used as transducer. These materials have provided good stability of electro- chemical measurements. The functionalized silicon-based transducers with a Cu(II)Pc-PAA membrane were characterized by using Mott-Schottky technique measurements at different frequency ranges and for different phosphate concentrations. The morphological surface of the Cu(II) Pc-PAA modified silicon-nitride based transducer was characterized by contact angle measurements and atomic force microscopy. The pH effect was also investigated by the Mott-Schottky technique for different Tris-HCl buffer solutions. The sensitivity of silicon nitride was e studied at different pH of Tris-HCl buffer solutions. This pH test has provided a sensitivity value of 51 mV/decade. The developed chemical sensor showed a good performance for phosphate ions detection within the range of 10-10 to 10-5 M with a Nernstian sensitivity of 27.7 mV/decade. The limit of detection of phosphate ions was determined at 1 nM. This chemical sensor was highly specific for phosphate ions when compared to other interfering ions as chloride, sulfate, carbonate and perchlorate. The present capacitive chemical sensor is thus very promising for sensitive and rapid detection of phosphate in environmental applications., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Miniaturized multiparametric flexible platform for the simultaneous monitoring of ionic: Application in real urine

  • Moya, Ana
  • Illa, Xavi
  • Giménez, Ignacio
  • Lazo-Fernández, Yoskaly
  • Villa, Rosa
  • Errachid, Abdelhamid
  • Gabriel, Gemma
Biomonitoring is a research topic that has largely relied on cell culture systems. Recently, the development of “Organ-on-a-Chip” (OC) platforms and the need for a continuous monitoring of these systems has increased its interest. However, the biomonitorization in these systems is still at its infancy due to the difficulty to adapt the sensors to microfluidic OC systems. In this work we have fabricated a modular, versatile, scalable, multi-analyte sensing platform, which integrates dissolved oxygen (DO), Na+, K+ and pH sensors for monitoring their concentrations in small volume of biological fluids. The platform is fabricated by means of rapid prototyping techniques using polymeric substrates, and incorporates all the necessary elements to measure the four analytes. It was designed with four gold sensing electrodes, and integrates a gold counter electrode and an Ag/AgCl pseudo-reference electrode for the electrochemical measurements in small volumes (0.83 µL) of samples. The sensors featured good sensitivities of 3.60 ± 0.2 nA (mg L-1) for DO and 69 ± 1 mV decade-1 for pH. Na+ and K+ µISE exhibited sensitivities of 57 ± 1 mV decade-1 and 52 ± 2 mV decade-1, and low limits of detection 5 × 10-6 M and 0.5 × 10-5 M respectively. This platform allows the dynamic measurement of the biological fluids parameters simultaneously, in real time and with a rapid response. The versatility of the platform allows its adaptation in any microfluidic cells culture systems. The novel multi-sensor platform has been validated in controlled buffers and with artificial urine (AU). A proof-of-concept using real mice urine (RU) has been carried out, demonstrating the good behaviour of the multi-sensing platform.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization

  • Pruna Morales, Raquel
  • Palacio Bonet, Francisco
  • Baraket, Abdoullatif
  • Bausells, Joan
  • Errachid, Abdelhamid
  • López de Miguel, Manuel
The development of miniaturized potentiostats capable of measuring in a wide range of conditions and with full characteristics (e.g., wide bandwidth and capacitive/inductive contribution to sensor's impedance) is still an unresolved challenge in bioelectronics. We present a simple analogue design coupled to a digital filter based on a lock-in amplifier as an alternative to complex architectures reported hitherto. A low-cost, miniaturized and fully integrated acquisition electronic system was developed, tested for a fully integrated three-lead electrochemical biosensor and benchmarked against a commercial potentiostat. The portable potentiostat was coupled to an array of miniaturized gold working electrodes to perform complex impedance analyses for tumor necrosis factor α (TNF-α) cytokine detection. This wearable potentiostat is very promising for the development of low-cost point-of-care (POC) with low power consumption.