Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 12
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Multiwell capillarity-based microfluidic device for the study of 3D tumour tissue-2D endothelium interactions and drug screening in co-culture models

  • Virumbrales-Muñoz, María
  • Ayuso, José María
  • Olave, Marta
  • Monge, Rosa
  • Miguel, Diego de
  • Martínez-Lostao, Luis
  • Le Gac, Séverine
  • Doblaré, Manuel
  • Ochoa, Ignacio
  • Fernández Ledesma, Luis Javier
The tumour microenvironment is very complex, and essential in tumour development and drug resistance. The endothelium is critical in the tumour microenvironment: it provides nutrients and oxygen to the tumour and is essential for systemic drug delivery. Therefore, we report a simple, user-friendly microfluidic device for co-culture of a 3D breast tumour model and a 2D endothelium model for cross-talk and drug delivery studies. First, we demonstrated the endothelium was functional, whereas the tumour model exhibited in vivo features, e.g., oxygen gradients and preferential proliferation of cells with better access to nutrients and oxygen. Next, we observed the endothelium structure lost its integrity in the co-culture. Following this, we evaluated two drug formulations of TRAIL (TNF-related apoptosis inducing ligand): soluble and anchored to a LUV (large unilamellar vesicle). Both diffused through the endothelium, LUV-TRAIL being more efficient in killing tumour cells, showing no effect on the integrity of endothelium. Overall, we have developed a simple capillary force-based microfluidic device for 2D and 3D cell co-cultures. Our device allows high-throughput approaches, patterning different cell types and generating gradients without specialised equipment. We anticipate this microfluidic device will facilitate drug screening in a relevant microenvironment thanks to its simple, effective and user-friendly operation., This work has been supported by the Spanish national research program (DPI2011-28262-c04-01, DPI2015-65401-C3-1-R, MTM2012-31073 and MAT2015-69967-C3-1 grants). M.V. studentship was supported by the Spanish national government, J.M.A. grant was supported by the Aragon Government., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Profiling of oxygen in biofilms using individually addressable disk microelectrodes on a microfabricated needle

  • Moya, Ana
  • Guimerà, Xavier
  • del Campo, Francisco Javier
  • Prats-Alfonso, Elisabet
  • Dorado, Antonio David
  • Baeza, Mireia
  • Villa, Rosa
  • Gabriel, David
  • Gamisans, Xavier
  • Gabriel, Gemma
A novel microelectrode array sensor was fabricated using MEMS technology on a needle, and then applied to real-time measurement of dissolved oxygen (DO) inside biofilms. The sensor consists of eleven gold disk microelectrodes, a rectangular auxiliary electrode along them, and an external and internal reference electrode. Three kinds of sensors were designed and their responses were characterized and evaluated under various conditions. The arrays exhibit a linear response to DO in the 0–8 mg·L<sup>−1</sup> concentration range in water, high sensitivity, repeatability, and low limits of detection (<0.11 mg·L<sup>−1</sup> of DO) and quantification (0.38 mg·L<sup>−1</sup> DO). The sensors were validated against a commercial Clark-type microelectrode and applied to profiling of DO in a heterotrophic biofilm cultivated in a flat-plate bioreactor. It is shown that the sensor array can provide a multipoint, simultaneous snapshot profile of DO inside a biofilm with high spatial resolution due to its micrometric dimensions. We conclude that this new sensor array represents a powerful tool for sensing of DO biofilms and in numerous bioprocesses.[Figure not available: see fulltext.], This work has been founded by projects DPI2011-28262-C04 and CTM2012-37927-C03/FEDER, financed by the Ministerio de Economía y Competitividad (Spain). AM gratefully ac-knowledges an FPI-2012 pre-doctoral scholarship, (it funded her PhD studies at Universitat Autònoma de Barcelona), and XG also acknowl- edges an FPI-UPC pre-doctoral scholarship, both from Ministerio de Economía y Competitividad (Spain)., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Study of the chemotactic response of multicellular spheroids in a microfluidic device

  • Ayuso, J.M.
  • Basheer, H.A.
  • Monge, R.
  • Sánchez-Álvarez, P.
  • Doblaré, M.
  • Shnyder, S.D.
  • Vinader, V.
  • Afarinkia, K.
  • Fernández, L.J.
  • Ochoa, I.
We report the first application of a microfluidic device to observe chemotactic migration in multicellular spheroids. A microfluidic device was designed comprising a central microchamber and two lateral channels through which reagents can be introduced. Multicellular spheroids were embedded in collagen and introduced to the microchamber. A gradient of fetal bovine serum (FBS) was established across the central chamber by addition of growth media containing serum into one of the lateral channels. We observe that spheroids of oral squamous carcinoma cells OSC-19 invade collectively in the direction of the gradient of FBS. This invasion is more directional and aggressive than that observed for individual cells in the same experimental setup. In contrast to spheroids of OSC-19, U87-MG multicellular spheroids migrate as individual cells. A study of the exposure of spheroids to the chemoattractant shows that the rate of diffusion into the spheroid is slow and thus, the chemoattractant wave engulfs the spheroid before diffusing through it.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Development and characterization of a microfluidic model of the tumour microenvironment

  • Ayuso, J.M.
  • Virumbrales-Muñoz, M.
  • Lacueva, A.
  • Lanuza, P.M.
  • Checa-Chavarria, E.
  • Botella, P.
  • Fernández, E.
  • Doblare, M.
  • Allison, S.J.
  • Phillips, R.M.
  • Pardo, J.
  • Fernandez, L.J.
  • Ochoa, I.
The physical microenvironment of tumours is characterized by heterotypic cell interactions and physiological gradients of nutrients, waste products and oxygen. This tumour microenvironment has a major impact on the biology of cancer cells and their response to chemotherapeutic agents. Despite this, most in vitro cancer research still relies primarily on cells grown in 2D and in isolation in nutrient- and oxygen-rich conditions. Here, a microfluidic device is presented that is easy to use and enables modelling and study of the tumour microenvironment in real-time. The versatility of this microfluidic platform allows for different aspects of the microenvironment to be monitored and dissected. This is exemplified here by real-time profiling of oxygen and glucose concentrations inside the device as well as effects on cell proliferation and growth, ROS generation and apoptosis. Heterotypic cell interactions were also studied. The device provides a live ‘window’ into the microenvironment and could be used to study cancer cells for which it is difficult to generate tumour spheroids. Another major application of the device is the study of effects of the microenvironment on cellular drug responses. Some data is presented for this indicating the device’s potential to enable more physiological in vitro drug screening.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Glioblastoma on a microfluidic chip: Generating pseudopalisades and enhancing aggressiveness through blood vessel obstruction events

  • Ayuso, Jose María
  • Monge, Rosa
  • Martinez-Gonzalez, Alicia
  • Virumbrales-Munoz, Maria
  • Llamazares, Guillermo A.
  • Berganzo, Javier
  • Hernandez-Lain, Aurelio
  • Santolaria, Jorge
  • Doblare, Manuel
  • Hubert, Christopher
  • Rich, Jeremy N.
  • Sanchez-Gomez, Pilar
  • Perez-Garcia, Victor M.
  • Ochoa, Ignacio
  • Fernandez, Luis J.
Background: Glioblastoma (GBM) is one of the most lethal tumor types. Hypercellular regions, named pseudo- palisades, are characteristic in these tumors and have been hypothesized to be waves of migrating glioblastoma cells.These “waves” of cells are thought to be induced by oxygen and nutrient depletion caused by tumor-induced blood vessel occlusion. Although the universal presence of these structures in GBM tumors suggests that they may play an instrumental role in GBM’s spread and invasion, the recreation of these structures in vitro has remained challenging. Methods: Here we present a new microfluidic model of GBM that mimics the dynamics of pseudopalisade forma- tion.To do this, we embedded U-251 MG cells within a collagen hydrogel in a custom-designed microfluidic device. By controlling the medium flow through lateral microchannels, we can mimic and control blood-vessel obstruction events associated with this disease. Results: Through the use of this new system, we show that nutrient and oxygen starvation triggers a strong migratory process leading to pseudopalisade generation in vitro.These results validate the hypothesis of pseudo- palisade formation and show an excellent agreement with a systems-biology model based on a hypoxia-driven phenomenon. Conclusions: This paper shows the potential of microfluidic devices as advanced artificial systems capable of mod- eling in vivo nutrient and oxygen gradients during tumor evolution.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Multiwell capillarity-based microfluidic device for the study of 3D tumour tissue-2D endothelium interactions and drug screening in co-culture models

  • Virumbrales-Muñoz, Maria
  • Ayuso, Jose María
  • Olave, Marta
  • Monge, Rosa
  • de Miguel, Diego
  • Martinez-Lostao, Luis
  • Le Gac, Séverine
  • Doblaré, Manuel
  • Ochoa, Ignacio
  • Fernández, Luis
The tumour microenvironment is very complex, and essential in tumour development and drug resistance. The endothelium is critical in the tumour microenvironment: it provides nutrients and oxygen to the tumour and is essential for systemic drug delivery. Therefore, we report a simple, user-friendly microfluidic device for co-culture of a 3D breast tumour model and a 2D endothelium model for cross-talk and drug delivery studies. First, we demonstrated the endothelium was functional, whereas the tumour model exhibited in vivo features, e.g., oxygen gradients and preferential proliferation of cells with better access to nutrients and oxygen. Next, we observed the endothelium structure lost its integrity in the co-culture. Following this, we evaluated two drug formulations of TRAIL (TNF-related apoptosis inducing ligand): soluble and anchored to a LUV (large unilamellar vesicle). Both diffused through the endothelium, LUV-TRAIL being more efficient in killing tumour cells, showing no effect on the integrity of endothelium. Overall, we have developed a simple capillary force-based microfluidic device for 2D and 3D cell co-cultures. Our device allows high-throughput approaches, patterning different cell types and generating gradients without specialised equipment. We anticipate this microfluidic device will facilitate drug screening in a relevant microenvironment thanks to its simple, effective and user-friendly operation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

High-order TRAIL oligomer formation in TRAIL-coated lipid nanoparticles enhances DR5 cross-linking and increases antitumour effect against colon cancer

  • Miguel, D. de
  • Gallego-Lleyda, A.
  • Ayuso, J. M.
  • Pejenaute-Ochoa, D.
  • Jarauta, V.
  • Marzo, I.
  • Fernández, L. J.
  • Ochoa, I.
  • Conde, B.
  • Anel, A.
  • Martinez-Lostao, L.
During the last years, a great effort has been invested into developing new TRAIL formulations with increased bioactivity, trying to overcome the resistance to conventional soluble TRAIL (sTRAIL) exhibited by many primary tumours. In our group, we have generated artificial lipid nanoparticles decorated with sTRAIL (LUV-TRAIL), emulating the physiological TRAIL-containing exosomes by which T-cells release TRAIL upon activation. We already demonstrated that LUV-TRAIL has greater cytotoxicity against both chemoresistant haematologic tumour cells and epithelial carcinoma cells compared to a form of sTRAIL similar to that used in clinical trials. In this study we have tested LUV-TRAIL in several human colon cancer cell lines with different sensitivity to sTRAIL. LUV-TRAIL significantly improved sTRAIL cytotoxicity in all colon cancer cell lines tested. Trying to ascertain the molecular mechanism by which LUV-TRAIL exhibited improved cytotoxicity, we demonstrated that TRAIL-coated lipid nanoparticles were able to activate DR5 more efficiently than sTRAIL, and this relied on LUV-TRAIL ability to promote DR5 clustering on the cell surface. Moreover, we show that TRAIL molecules are arranged in higher order oligomers only in LUV-TRAIL, which may explain their enhanced DR5 clustering ability. Finally, LUV-TRAIL showed significantly better antitumour activity than sTRAIL in an in vivo model using HCT-116 xenograft tumours in nude mice, validating its potential clinical application.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

SU-8 Based Microdevices to Study Self-Induced Chemotaxis in 3D Microenvironments

  • Ayuso, Jose Maria
  • Monge, Rosa
  • Llamazares, Guillermo A.
  • Moreno, Marco
  • Agirregabiria, Maria
  • Berganzo, Javier
  • Doblaré, Manuel
  • Ochoa, Ignacio
  • Fernández, Luis J.
Tissues are complex three-dimensional structures in which cell behavior is frequently guided by chemotactic signals. Although starvation and nutrient restriction induce many different chemotactic processes, the recreation of such conditions in vitro remains difficult when using standard cell culture equipment. Recently, microfluidic techniques have arisen as powerful tools to mimic such physiological conditions. In this context, microfluidic three-dimensional cell culture systems require precise control of cell/hydrogel location because samples need to be placed within a microchamber without obstruction of surrounding elements. In this article, SU-8 is studied as structural material for the fabrication of complex cell culture microdevices due to its good mechanical properties and sensor integration capacity. Moreover, SU-8 physical properties and their effect on a successful design for precise control of hydrogel location within microfluidic devices are studied. In particular, this manuscript presents a SU-8 based microdevice designed to create “self-induced” medium starvation, based on the combination of nutrient restriction and natural cell metabolism. Results show a natural migratory response toward nutrient source, showing how cells adapt to their own microenvironment modifications. The presented results demonstrate the SU-8 potential for microdevice fabrication applied to cell culture.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A perfusion chamber for monitoring transepithelial NaCl transport in an in vitro model of the renal tubule

  • Yeste, J.
  • Martínez-Gimeno, L.
  • Illa, X.
  • Laborda, P.
  • Guimerà, A.
  • Sánchez-Marín, J.P.
  • Villa, R.
  • Giménez, I.
Transepithelial electrical measurements in the renal tubule have provided a better understanding of how kidney regulates electrolyte and water homeostasis through the reabsorption of molecules and ions (e.g., H2O and NaCl). While experiments and measurement techniques using native tissue are difficult to prepare and to reproduce, cell cultures conducted largely with the Ussing chamber lack the effect of fluid shear stress which is a key physiological stimulus in the renal tubule. To overcome these limitations, we present a modular perfusion chamber for long-term culture of renal epithelial cells under flow that allows the continuous and simultaneous monitoring of both transepithelial electrical parameters and transepithelial NaCl transport. The latter is obtained from electrical conductivity measurements since Na+ and Cl- are the ions that contribute most to the electrical conductivity of a standard physiological solution. The system was validated with epithelial monolayers of raTAL and NRK-52E cells that were characterized electrophysiologically for 5 days under different flow conditions (i.e., apical perfusion, basal, or both). In addition, apical to basal chemical gradients of NaCl (140/70 and 70/140 mM) were imposed in order to demonstrate the feasibility of this methodology for quantifying and monitoring in real time the transepithelial reabsorption of NaCl, which is a primary function of the renal tubule.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Miniaturized multiparametric flexible platform for the simultaneous monitoring of ionic: Application in real urine

  • Moya, Ana
  • Illa, Xavi
  • Giménez, Ignacio
  • Lazo-Fernández, Yoskaly
  • Villa, Rosa
  • Errachid, Abdelhamid
  • Gabriel, Gemma
Biomonitoring is a research topic that has largely relied on cell culture systems. Recently, the development of “Organ-on-a-Chip” (OC) platforms and the need for a continuous monitoring of these systems has increased its interest. However, the biomonitorization in these systems is still at its infancy due to the difficulty to adapt the sensors to microfluidic OC systems. In this work we have fabricated a modular, versatile, scalable, multi-analyte sensing platform, which integrates dissolved oxygen (DO), Na+, K+ and pH sensors for monitoring their concentrations in small volume of biological fluids. The platform is fabricated by means of rapid prototyping techniques using polymeric substrates, and incorporates all the necessary elements to measure the four analytes. It was designed with four gold sensing electrodes, and integrates a gold counter electrode and an Ag/AgCl pseudo-reference electrode for the electrochemical measurements in small volumes (0.83 µL) of samples. The sensors featured good sensitivities of 3.60 ± 0.2 nA (mg L-1) for DO and 69 ± 1 mV decade-1 for pH. Na+ and K+ µISE exhibited sensitivities of 57 ± 1 mV decade-1 and 52 ± 2 mV decade-1, and low limits of detection 5 × 10-6 M and 0.5 × 10-5 M respectively. This platform allows the dynamic measurement of the biological fluids parameters simultaneously, in real time and with a rapid response. The versatility of the platform allows its adaptation in any microfluidic cells culture systems. The novel multi-sensor platform has been validated in controlled buffers and with artificial urine (AU). A proof-of-concept using real mice urine (RU) has been carried out, demonstrating the good behaviour of the multi-sensing platform.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Graphene oxide increases the viability of C2C12 myoblasts microencapsulated in alginate

  • Ciriza, J.
  • Saenz Del Burgo, L.
  • Virumbrales-Muñoz, M.
  • Ochoa, I.
  • Fernandez, L. J.
  • Orive, G.
  • Hernandez, M. R.
  • Pedraz, J. L.
Cell microencapsulation represents a great promise for long-term drug delivery, but still several challenges need to be overcome before its translation into the clinic, such as the long term cell survival inside the capsules. On this regard, graphene oxide has shown to promote proliferation of different cell types either in two or three dimensions. Therefore, we planned to combine graphene oxide with the cell microencapsulation technology. We first studied the effect of this material on the stability of the capsules and next we analyzed the biocompatibility of this chemical compound with erythropoietin secreting C2C12 myoblasts within the microcapsule matrix. We produced 160 μm-diameter alginate microcapsules with increasing concentrations of graphene oxide and did not find modifications on the physicochemical parameters of traditional alginate microcapsules. Moreover, we observed that the viability of encapsulated cells within alginate microcapsules containing specific graphene oxide concentrations was enhanced. These results provide a relevant step for the future clinical application of graphene oxide on cell microencapsulation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A simple method for the isolation and detailed characterization of primary human proximal tubule cells for renal replacement therapy

  • Sanchez-Romero, Natalia
  • Martinez-Gimeno, Laura
  • Gaetano-Pinto, Pedro
  • Saez, Berta
  • Sanchez-Zalabardo, José Manuel
  • Masereeuw, Rosalinde
  • Gimenez, Ignacio
The main physiological functions of renal proximal tubule cells in vivo are reabsorption of essential nutrients from the glomerular filtrate and secretion of waste products and xenobiotics into urine. Currently, there are several established cell lines of human origin available as in vitro models of proximal tubule. However, these cells appeared to be limited in their biological relevance, because essential characteristics of the original tissue are lost once the cells are cultured. As a consequence of these limitations, primary human proximal tubule cells constitute a suitable and a biologically more relevant in vitro model to study this specific segment of the nephron and therefore, these cells can play an important role in renal regenerative medicine applications. Here, we describe a protocol to isolate proximal tubule cells from human nephrectomies. We explain the steps performed for an in-depth characterization of the cells, including the study of markers from others segments of the nephron, with the goal to determine the purity of the culture and the stability of proteins, enzymes, and transporters along time. The human proximal tubule cells isolated and used throughout this study showed many proximal tubule characteristics, including monolayer organization, cell polarization with the expression of tight junctions and primary cilia, expression of proximal tubule-specific proteins, such as megalin and sodium/glucose cotransporter 2, among others. The cells also expressed enzymatic activity for dipeptidyl peptidase IV, as well as for gamma glutamyl transferase 1, and expressed transporter activity for organic anion transporter 1, P-glycoprotein, multidrug resistance proteins, and breast cancer resistance protein. In conclusion, characterization of our cells confirmed presence of putative proximal tubule markers and the functional expression of multiple endogenous organic ion transporters mimicking renal reabsorption and excretion. These findings can constitute a valuable tool in the development of bioartificial kidney devices.