Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A Highly Sensitive Potentiometric Amphetamine Microsensor Based on All-Solid-State Membrane Using a New Ion-Par Complex, [3,3′-Co(1,2-closo-C2B9H11)2]− C9H13NH+

  • Gallardo González, Juan
  • Baraket, Abdellatif
  • Boudjaoui, S.
  • Clément, Y.
  • Alcácer, A.
  • Streklas, A.
  • Teixidor, Francesc
  • Zine, Nadia
  • Bausells, Joan
  • Errachid, Abdelhamid
In the present work a highly sensitive ion-selective microelectrode for the detection of amphetamine is presented. For this purpose, a novel ion-par complex based on the metallocarborane, cobalt bis(dicarbollide) anion ([3,3′-Co(1,2-C<sub>2</sub>B<sub>9</sub>H<sub>11</sub>)<sub>2</sub>]<sup>−</sup>) coupled to amphetamonium cation has been prepared as the active site for amphetamine recognition. The prepared ion-par complex was incorporated to a PVC-type sensitive membrane. It was then drop-casted on the top of a gold microelectrode previously modified with a solid contact layer of polypyrrole. This novel amphetamine microsensor has provided excellent and quick response within the range 10<sup>−5</sup> M to 10<sup>−3</sup> M of amphetamine concentration, a limit of detection of 12 µM and a slope of 60.1 mV/decade. It was also found to be highly selective toward some potential interference compounds when compared to amphetamine., The authors acknowledge the financial support from the European Union’s Horizon 2020 research and innovation programme entitled MicroMole and HEARTEN grant agreement No. 653626 and No. 643694 respectively
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Silicon Nitride Capacitive Chemical Sensor for Phosphate Ion Detection Based on Copper Phthalocyanine – Acrylate-polymer

  • Barhoumi, Lassaad
  • Baraket, Abdoullatif
  • Nooredeen, Naglaa Mohammed
  • Ben Ali, Mounir
  • Nooredeen Abbas, Mohammed
  • Bausells, Joan
  • Errachid, Abdelhamid
In this work, we report the development of a highly sensitive capacitance chemical sensor based on a copper C,C,C,C-tetra-carboxylic phthalocyanine-acrylate polymer adduct (Cu(II)TCPc-PAA) for phosphate ions detection. A capacitance silicon nitride substrate based AlCu/Si-p/SiO2/Si3N4 structure was used as transducer. These materials have provided good stability of electro- chemical measurements. The functionalized silicon-based transducers with a Cu(II)Pc-PAA membrane were characterized by using Mott-Schottky technique measurements at different frequency ranges and for different phosphate concentrations. The morphological surface of the Cu(II) Pc-PAA modified silicon-nitride based transducer was characterized by contact angle measurements and atomic force microscopy. The pH effect was also investigated by the Mott-Schottky technique for different Tris-HCl buffer solutions. The sensitivity of silicon nitride was e studied at different pH of Tris-HCl buffer solutions. This pH test has provided a sensitivity value of 51 mV/decade. The developed chemical sensor showed a good performance for phosphate ions detection within the range of 10-10 to 10-5 M with a Nernstian sensitivity of 27.7 mV/decade. The limit of detection of phosphate ions was determined at 1 nM. This chemical sensor was highly specific for phosphate ions when compared to other interfering ions as chloride, sulfate, carbonate and perchlorate. The present capacitive chemical sensor is thus very promising for sensitive and rapid detection of phosphate in environmental applications., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Miniaturized multiparametric flexible platform for the simultaneous monitoring of ionic: Application in real urine

  • Moya, Ana
  • Illa, Xavi
  • Giménez, Ignacio
  • Lazo-Fernández, Yoskaly
  • Villa, Rosa
  • Errachid, Abdelhamid
  • Gabriel, Gemma
Biomonitoring is a research topic that has largely relied on cell culture systems. Recently, the development of “Organ-on-a-Chip” (OC) platforms and the need for a continuous monitoring of these systems has increased its interest. However, the biomonitorization in these systems is still at its infancy due to the difficulty to adapt the sensors to microfluidic OC systems. In this work we have fabricated a modular, versatile, scalable, multi-analyte sensing platform, which integrates dissolved oxygen (DO), Na+, K+ and pH sensors for monitoring their concentrations in small volume of biological fluids. The platform is fabricated by means of rapid prototyping techniques using polymeric substrates, and incorporates all the necessary elements to measure the four analytes. It was designed with four gold sensing electrodes, and integrates a gold counter electrode and an Ag/AgCl pseudo-reference electrode for the electrochemical measurements in small volumes (0.83 µL) of samples. The sensors featured good sensitivities of 3.60 ± 0.2 nA (mg L-1) for DO and 69 ± 1 mV decade-1 for pH. Na+ and K+ µISE exhibited sensitivities of 57 ± 1 mV decade-1 and 52 ± 2 mV decade-1, and low limits of detection 5 × 10-6 M and 0.5 × 10-5 M respectively. This platform allows the dynamic measurement of the biological fluids parameters simultaneously, in real time and with a rapid response. The versatility of the platform allows its adaptation in any microfluidic cells culture systems. The novel multi-sensor platform has been validated in controlled buffers and with artificial urine (AU). A proof-of-concept using real mice urine (RU) has been carried out, demonstrating the good behaviour of the multi-sensing platform.