Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 31
Encontrada(s) 1 página(s)

e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Novel nanostructured indium tin oxide electrode for electrochemical immunosensors: Suitability for the detection of TNF-a

  • Pruna I Morales, Raquel
  • Baraket, Abdoullatif
  • Bonhommé, Anne
  • Zine, Nadia
  • Errachid, Abdelhamid
  • López, Manuel
The need for new and innovative point of care (POC) systems providing a feasible alternative to costly and time consuming standard laboratory techniques is becoming more evident every day, particularly in the case of cardiovascular diseases. Coupling optical and electrochemical principles for highly specific and sensitive detection of biomarkers could boost the successful implementation of POC systems in biomedical environments. We suggest indium tin oxide (ITO) as a promising material for working electrodes in optoelectrochemical sensors, owing to the rare combination of high electrical conductivity and optical transparency it presents. Moreover, the nanostructured nature of the electrodes' surface is crucial for an eventual miniaturization of the POC system. In this work, we describe the construction and characterization of a nanostructured ITO electrode modified with aryl diazonium salt as transparent substrate for electrochemical immunosensors. The developed electrode was tested for the detection of tumour necrosis factor alfa (TNF-alfa), a cardiac biomarker playing an important role in the prevention of heart failure. Macro and microscopic evidences (gathered from electrochemical and spectral techniques) of covalent bonding and high surface coverage are provided. Specific interaction between antigen (TNF-alfa) and monoclonal antibody (Ab-TNF-alfa) was verified by fluorescence patterning, confirming the proper bio-recognition of the cytokine. As a proof-of-concept, results of electrochemical impedance spectroscopy (EIS) show stabilized semi-quantitative label-free detection of TNF-alfa at several concentrations (from 10 pg/mL to 100 pg/mL). These preliminary results demonstrate the feasibility of using transparent substrates for the detection of cytokines at low concentrations, and the consequent application in POC systems for the monitoring of cardiovascular diseases., The research leading to these results has received funding from the European Union's 7FP (SEA-on-a-CHIP, Grant Agreement no. 614168) and the European Union's Horizon 2020 (HEARTEN, Grant Agreement no. 643694). R.P. acknowledges an FPU grant from the Spanish Ministerio de Educación, Cultura y Deporte.
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

A low-cost and miniaturized potentiostat for the monitoring of immunobiosensors by electrochemical impedance spectroscopy

  • Pruna I Morales, Raquel
  • Palacio, Francisco
  • Baraket, Abdoullatif
  • Zine, Nadia
  • Streklas, Angelos
  • Bausells, Joan
  • Errachid, Abdelhamid
  • López, Manuel
Miniaturizing potentiostats, keeping their cost low and yet preserving full measurement characteristics (e.g. bandwidth, determination of capacitive/inductive contribution to sensor's impedance and parallel screening) is still an unresolved challenge in bioelectronics. In this work, the combination of simple analogue circuitry together with powerful microcontrollers and a digital filter implementation is presented as an alternative to complex and incomplete architectures reported in the literature. A low-cost acquisition electronic system fully integrated with a biosensors platform containing eight gold working microelectrodes and integrated reference and counter electrodes was developed and validated. The manufacturing cost of the prototype was kept below 300 USD. The performance of the proposed device was benchmarked against a commercial impedance analyzer through the electrochemical analysis of a highly sensitive biosensor for the detection of tumor necrosis factor alfa (TNF-alfa) within the randomly chosen range of 266pg/mL to 666ng/mL in physiological medium (PBS). A strong correlation between the outputs of both devices was found in a critical range of frequencies (1-10Hz), and several TNF-alfa cytokine concentrations were properly discriminated. These results are very promising for the development of low-cost, portable and miniaturized electrochemical systems for point-of-care and environmental diagnosis., The research leading to these results has received funding from the European Union's 7FP (SEA-on-a-CHIP, Grant Agreement no. 614168) and the European Union's Horizon 2020 (HEARTEN, Grant Agreement no. 643694). R.P. acknowledges an FPU grant (FPU15/00771) from the Spanish Ministerio de Educación, Cultura y Deporte.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Enhanced conductivity of sodium versus lithium salts. Sodium metallacarboranes as electrolyte

  • Fuentes, I.
  • Andrio, Andreu
  • Teixidor, F.
  • Viñas, Clara
  • Compañ Moreno, Vicente|||0000-0001-8233-7472
[EN] The development of new types of ion conducting materials is one of the most important challenges in the field of energy. Lithium salt polymer electrolytes have been the most convenient, and thus the most widely used in the design of the new generation of batteries. However, in this work, we have observed that Na+ ions provide a higher conductivity, or at least a comparable conductivity to that of Li+ ions in the same basic material. This provides an excellent possibility to use Na+ ions in the design of a new generation of batteries, instead of lithium, to enhance conductivity and ensure wide supply. Our results indicate that the dc-conductivity is larger when the anion is [Co(C2B9H11)(2)](-), [COSANE](-), compared to tetraphenylborate, [TPB](-). Our data also prove that the dc-conductivity behavior of Li+ and Na+ salts is opposite with the two anions. At 40 C-omicron, the conductivity values change from 1.05 x 10(-2) S cm(-1) (Li[COSANE]) and 1.75 x 10(-2) S cm(-1) (Na[COSANE]) to 2.8 x 10(-3) S cm(-1) (Li[TPB]) and 1.5 x 10(-3) S cm(-1) (Na[TPB]). These findings indicate that metallacarboranes can be useful components of mixed matrix membranes (MMMs), providing excellent conductivity when the medium contains sufficient amounts of ionic components and a certain degree of humidity., This research has been supported by the ENE/2015-69203-R and CTQ2013-44670-R projects, granted by the Ministerio de Economia y Competitividad (MINECO), Spain; the Generalitat de Catalunya (2014/SGR/149) and FP7-OCEAN-2013: Proposal number: 614168. C. V. thanks COST CM1302 project. I. F. is enrolled in the PhD program of the UAB.
Dipòsit Digital de la UB
Publication Artículo científico (JournalArticle)

Characterization of linear-mode avalanche photodiodes in standard CMOS

  • Vilella Figueras, Eva
  • Vilà i Arbonès, Anna Maria
  • Palacio, Fernando
  • López de Miguel, Manuel
  • Diéguez Barrientos, Àngel
Linear-mode Avalanche PhotoDiodes (APDs) can be fabricated in standard CMOS processes for obtaining high multiplication gains that allow to determine the number of incident photons with great precision. This idea can be exploited in several application domains, such as image sensors, optical communications and quantum information. In this work, we present a linear-mode APD fabricated in a 0.35 µm CMOS process and report its noise and gain characterization by means of two different experimental set-ups. Good matching is observed between the results obtained by means of the two different methods.
Dipòsit Digital de la UB
Publication Artículo científico (JournalArticle)

Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization

  • Pruna Morales, Raquel
  • Palacio Bonet, Francisco
  • Baraket, Abdoullatif
  • Bausells, Joan
  • Errachid, Abdelhamid
  • López de Miguel, Manuel
The development of miniaturized potentiostats capable of measuring in a wide range of conditions and with full characteristics (e.g., wide bandwidth and capacitive/inductive contribution to sensor's impedance) is still an unresolved challenge in bioelectronics. We present a simple analogue design coupled to a digital filter based on a lock-in amplifier as an alternative to complex architectures reported hitherto. A low-cost, miniaturized and fully integrated acquisition electronic system was developed, tested for a fully integrated three-lead electrochemical biosensor and benchmarked against a commercial potentiostat. The portable potentiostat was coupled to an array of miniaturized gold working electrodes to perform complex impedance analyses for tumor necrosis factor α (TNF-α) cytokine detection. This wearable potentiostat is very promising for the development of low-cost point-of-care (POC) with low power consumption.
Dipòsit Digital de la UB
Publication Artículo científico (JournalArticle)

Large area in situ fabrication of Poly(pyrrole)-nanowires on flexible thermoplastic films using Nanocontact printing

  • Garcia-Cruz, Álvaro
  • Lee, Michael
  • Marote, Pedro
  • Zine, Nadia
  • Sigaud, Monique
  • Bonhomme, Anne
  • Pruna Morales, Raquel
  • López de Miguel, Manuel
  • Bausells, Joan
  • Jaffrezic, Nicole
  • Errachid, Abdelhamid
Abstract: Highly efficient nano-engineering tools will certainly revolutionize the biomedical and sensing devices research and development in the years to come. Here, we present a novel high performance conducting poly(pyrrole) nanowires (PPy-NW) patterning technology on thermoplastic surfaces (poly(ethylene terephthalate (PETE), poly(ethylene 2,6-naphthalate (PEN), polyimide (PI), and cyclic olefin copolymer (COC)) using nanocontact printing and controlled chemical polymerization (nCP-CCP) technique. The technique uses a commercial compact disk (CD) as a template to produce nanopatterned polydimethylsiloxane (PDMS) stamps. The PDMS nanopatterned stamp was applied to print the PPy-NWs and the developed technology of nCP-CCP produced 3D conducting nanostructures. This new and very promising nanopatterning technology was achieved in a single step and with a low cost of fabrication over large areas.
Dipòsit Digital de la UB
Publication Artículo científico (JournalArticle)

Portable flow multiplexing device for continuous, in situ biodetection of environmental contaminants

  • Salvador Vico, Juan Pablo
  • Marco Colás, Ma. Pilar
  • Saviozzi, Giacomo
  • Laschi, Cecilia
  • Arreza Martín, Fernando Jesús
  • Palacio Bonet, Francisco
  • López de Miguel, Manuel
A compact, low-cost and low-powered device was developed and arranged for multiplexed biodetection of sea water contaminants from continuous flow mode. Electronics, mechanics and fluidics were designed to guarantee identical functional liquid flow through eight parallel sensor microchambers during a predetermined time period providing 8 values at the same time. The accuracy and repeatability of the device was tested in-lab, achieving a deviation of less than 10% when measuring the same analyte in all the chambers. The experimental results obtained with our device were finally compared with those measured in continuous flux by a commercial potentiostat SP150 (Bio-Logic Science Instruments), obtaining identical results, which validated the proposed device.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Water research in the Mediterranean: challenges and perspectives. The Catalan Institute for Water Research (ICRA)

  • Sabater, Sergi
  • Acuña, Vicenç
  • Batalla, Ramón J.
  • Balcázar, José Luis
  • Borrego, Carles
  • Insa, Sara
  • Marcé, Rafael
  • Mas Pla, Josep
  • Petrovic, Mira
  • Pijuan, Maite
  • Rodriguez-Mozaz, Sara
  • Rodríguez-Roda, I.
  • Villagrasa, Marta
  • Barceló, Damià
The mission of the Catalan Institute for Water Research (ICRA) is to implement a holistic, multidisciplinary approach to water research, taking into account all components related to freshwaters and human-used waters. The ICRA has developed a coordinated, cooperative organization structure to allow this multidisciplinary approach across a broad spectrum of water related sciences and technologies. ICRA’s main goals are to provide scientific and technological perspectives and tools to issues derived from water needs, scarcity, and ecosystem conservation in the Mediterranean context., This work has been supported by the Spanish Ministry of Economy and Competiveness through the project SCARCE of Consolider-Ingenio 2010 program (CSD2009-00065) and the projects CARBONET (CGL2011-30474-C02-01), GEISTTAR (CTM 2011-27163), WATERFATE (CTM2012-38314-C02-01), (DEGRAPHARMAC-CTQ2010-21776-CO2-02), CDTI INNPRONTA ITACA project (IPT-2011102), MBRControl (CDTI - OHL MedioAmbiente INIMA SAU) andARCOS (CGL2012-33033). It also received funding from the European Community 7th Framework Programme under Grant Agreement No. 603629-ENV-2013-6.2.1-GLOBAQUA, ECsafeSEAFOOD (FP7 KBBE 311820), ENDETECH (FP7-ENV-2011-Eco-innovation), and SEA-on-a-CHIP. Also, the Marie Curie Reintegration Grants (2010-RG-277050; FP7-PEOPLE-2011-CIG 303946) and the Marie Curie Initial Training Network SANITAS (ITN-289193). M. Pijuan also acknowledges the Ramon y Cajal research fellowship (RYC-2009-04959) provided by the Spanish Government., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Effect of pyrethroid treatment against sea lice in salmon farming regarding consumers' health

  • Aznar-Alemany, Òscar
  • Eljarrat, Ethel
  • Barceló, Damià
Pyrethroids are the most popular drug against sea lice in salmon farming. Although they are more toxic to insects, they have toxic effects in mammals. Pyrethroids were detected in 100% of farmed salmon with a mean concentration of 1.31 ± 1.39 ng g−1 ww and in 50% of wild salmon with a mean of 0.02 ± 0.03 ng g−1 ww. Cypermethrin and deltamethrin, the active ingredients of anti-sea lice formulations, represented 77   ±  27% of the total contamination of farmed salmon. Although farmed salmon had higher concentrations than wild salmon, the daily intake of pyrethroids through salmon consumption was several orders of magnitude below the accepted daily intake (ADI). Thus, the pyrethroids treatment on salmon does not pose a threat on the health of the consumers. © 2017 Elsevier Ltd, This work has been financially supported by the European project ‘Real time monitoring of SEA contaminants by an autonomous lab‐on‐a‐chip biosensor’ (SEA‐ona‐CHIP; No. 614168) and the Generalitat de Catalunya (Consolidated Research Group2014 SGR 418 – Water and Soil Quality Unit). Biotage is acknowledged for SPE cartridges. Wild Alaska Salmon is acknowledged for some wild salmon samples., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Low-Cost Impedance Measurements for Lab-on-a-Chip Architectures: Towards Potentiostat Miniaturization

  • Pruna, Raquel
  • Palacio, Francisco
  • Baraket, Abdellatif
  • Bausells, Joan
  • Errachid, Abdelhamid
  • López, Manel
The development of miniaturized potentiostats capable of measuring in a wide range of conditions and with full characteristics (e.g., wide bandwidth and capacitive/inductive contribution to sensor’s impedance) is still an unresolved challenge in bioelectronics. We present a simple analogue design coupled to a digital filter based on a lock-in amplifier as an alternative to complex architectures reported hitherto. A low-cost, miniaturized and fully integrated acquisition electronic system was developed, tested for a fully integrated three-lead electrochemical biosensor and benchmarked against a commercial potentiostat. The portable potentiostat was coupled to an array of miniaturized gold working electrodes to perform complex impedance analyses for tumor necrosis factor α (TNF-α) cytokine detection. This wearable potentiostat is very promising for the development of low-cost point-of-care (POC) with low power consumption., The research leading to these results has received funding from the European Union’s 7FP (SEA-on-a-CHIP, Grant Agreement No. 614168) and the European Union’s Horizon 2020 (HEARTEN, Grant Agreement No. 643694). R.P. acknowledges an FPU grant from the Spanish Ministerio de Educación, Cultura y Deporte.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Electrochemical capacitive K+ EMIS chemical sensor based on the dibromoaza[7]helicene as an ionophore for potassium ions detection

  • Tounsi, Moncef
  • Zabala, Miguel
  • Bausells, Joan
  • Errachid, Abdelhamid
Tounsi, Moncef et al., A K+-sensitive capacitive electrolyte-membrane-insulator-semiconductor (EMIS) based on a novel dibromoaza[7]helicene ionophore has been developed. An ion-sensitive membrane based on polyvinylchloride (PVC) doped with the ionophore was deposited on the Si3N4/SiO2/Si-p/Cu-Al transducer. The properties of the K+-EMIS chemical sensor were investigated by electrochemical impedance spectroscopy (EIS). All the developed devices upon being tested have shown good sensitivity and linearity responses within the range 10-6 M to 10-1 M of potassium activity, with good selectivity over a wide variety of other cations (Na+, Li+, Cu2+, Ca2+, and Mg2+). To our knowledge, this is the first time that a capacitive field-effect sensor has been fabricated using helicene as a carrier for a K+-detection, combined with the structure Si3N4/SiO2/Si-p/Cu-Al as a transducer., We acknowledge the funding through the European Communities Seventh Framework Programme entitled Sea-on-a-Chip (FP7-OCEAN-2013) (No.614168), the European Union's Horizon 2020 Research and Innovation Programme entitled HEARTEN under grant agreement No 643694, NATO (CBP.NUKR.SFP 984173), and FP7-PEOPLE-2012-IRSES under the grant agreement No. 318053 (SMARTCANCERSENS). M. T. would like to acknowledge PHC-12 Mag088 project, and the Ministry of Higher Education and Scientific Research of Tunisia (LR11ES55)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Development of a novel capacitance electrochemical biosensor based on silicon nitride for ochratoxin A detection

  • Bougrinia, Madiha
  • Baraket, Abdoullatif
  • Jamshaid, Talha
  • El Aissari, Abdelhamid
  • Bausells, Joan
  • Zabala, Miguel
  • El Bari, Nezha
  • Bouchikhi, Benachir
  • Jaffrezic-Renault, Nicole
  • Errachid, Abdelhamid
  • Zine, Nadia
We report in this paper about the development of a novel capacitance electrochemical biosensor based on silicon nitride substrate (SiN) combined with a new structure of mangnetic nanoparticles (MNPs). SiN is highly stable as it was fabricated by a combination of several layers of Aluminum (Al), silicon p-doped (Si-p), silicon dioxide (SiO) and silicon nitride (SiN). This structure (SiN/SiO/Si-p/Al) has provided several advantages compared with other materials commonly used, and in particular in solid-state physics for electronic-based biosensors. The MNPs with terminated carboxylic acid were covalently bonded to SiN through a Self-Assembled Monolayers (SAMs) of the silane-amine (3-Aminopropyl) triethoxysilane (APTES). Finally anti-ochratoxin A antibodies were immobilized on MNPs by amide bonding. Contact Angle measurements, Atomic Force Microscopy, Scanning Electron Microscopy and Fluorescence Microscopy characterizations were performed during the biofunctionalization of the biosensor surface. Electrochemical measurements were carried out using Mott-Schottky analysis for ochratoxin A detection. The biosensor was highly sensitive and specific for ochratoxin A antigens, with a limit of detection of 4.57 pM, when compared to other interferences ochratoxin B and aflatoxin G1. The measurements were highly stable and reproducible for detection and interferences. The proposed method is very promising for ochratoxin A detection of several agro-food industry applications., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Silicon Nitride Capacitive Chemical Sensor for Phosphate Ion Detection Based on Copper Phthalocyanine – Acrylate-polymer

  • Barhoumi, Lassaad
  • Baraket, Abdoullatif
  • Nooredeen, Naglaa Mohammed
  • Ben Ali, Mounir
  • Nooredeen Abbas, Mohammed
  • Bausells, Joan
  • Errachid, Abdelhamid
In this work, we report the development of a highly sensitive capacitance chemical sensor based on a copper C,C,C,C-tetra-carboxylic phthalocyanine-acrylate polymer adduct (Cu(II)TCPc-PAA) for phosphate ions detection. A capacitance silicon nitride substrate based AlCu/Si-p/SiO2/Si3N4 structure was used as transducer. These materials have provided good stability of electro- chemical measurements. The functionalized silicon-based transducers with a Cu(II)Pc-PAA membrane were characterized by using Mott-Schottky technique measurements at different frequency ranges and for different phosphate concentrations. The morphological surface of the Cu(II) Pc-PAA modified silicon-nitride based transducer was characterized by contact angle measurements and atomic force microscopy. The pH effect was also investigated by the Mott-Schottky technique for different Tris-HCl buffer solutions. The sensitivity of silicon nitride was e studied at different pH of Tris-HCl buffer solutions. This pH test has provided a sensitivity value of 51 mV/decade. The developed chemical sensor showed a good performance for phosphate ions detection within the range of 10-10 to 10-5 M with a Nernstian sensitivity of 27.7 mV/decade. The limit of detection of phosphate ions was determined at 1 nM. This chemical sensor was highly specific for phosphate ions when compared to other interfering ions as chloride, sulfate, carbonate and perchlorate. The present capacitive chemical sensor is thus very promising for sensitive and rapid detection of phosphate in environmental applications., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Assessment of analytical methods to determine pyrethroids content of bednets

  • Castellarnau, Marc
  • Ramón-Azcón, Javier
  • González-Quinteiro, Yolanda
  • López, Jordi F.
  • Grimalt, Joan O.
  • Marco, María Pilar
  • Nieuwenhuijsen, Mark J.
  • Picado, Albert
Objective: To present and evaluate simple, cost-effective tests to determine the amount of insecticide on treated materials. Methods: We developed and evaluated a competitive immunoassay on two different platforms: a label-free impedimetric biosensor (EIS biosensor) and a lateral flow. Both approaches were validated by gas chromatography (GC) and ELISA, gold standards for analytical methods and immunoassays, respectively. Finally, commercially available pyrethroid-treated ITN samples were analysed. Different extraction methods were evaluated. Results: Insecticide extraction by direct infusion of the ITN samples with dichloromethane and dioxane showed recovery efficiencies around 100% for insecticide-coated bednets, and >70% for insecticide-incorporated bednets. These results were comparable to those obtained with standard sonication methods. The competitive immunoassay characterisation with ELISA presented a dynamic range between 12 nm and 1.5 μm (coefficient of variation (CV) below 5%), with an IC50 at 138 nm, and a limit of detection (LOD) of 3.2 nm. EIS biosensor had a linear range between 1.7 nm and 61 nm (CV around 14%), with an IC50 at 10.4 nm, and a LOD of 0.6 nm. Finally, the lateral flow approach showed a dynamic range between 150 nm and 1.5 μm, an IC50 at 505 nm and a LOD of 67 nm. Conclusions: ELISA can replace chromatography as an accurate laboratory technique to determine insecticide concentration in bednets. The lateral flow approach developed can be used to estimate ITN insecticide concentration in the field. This new technology, coupled to the new extraction methods, should provide reliable guidelines for ITN use and replacement in the field. © 2016 John Wiley & Sons Ltd, Project funded by the CERCA Institutes Integration Program (SUMA 2013) [promoted and managed by the Secretariat for Universities and Research of the Ministry Economy and Knowledge of the Government of Catalonia (SUR), the Agency for Management of University and Research Grants (AGAUR) and the CERCA Institute]. The research performed has also count with the support of the EC-FP7 SEA-ON A CHIP project (FP7-OCEAN-2013-1-614168). The Nb4D group is a consolidated research group (Grup de Recerca) of the Generalitat de Catalunya and has support from the Departament d'Universitats, Recerca i Societat de la Informaci? de la Generalitat de Catalunya (expedient: 2014 SGR 1484). CIBER-BBN is an initiative funded by the Spanish National Plan for Scientific and Technical Research and Innovation 2013?2016, Iniciativa Ingenio 2010, Consolider Program, CIBER Actions are financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund. The authors would like to thank Professor Bruce Hammock and Shirley Gee, from the Department of Entomology of University of California Davis, for providing the immunoreagents for deltamethrin detection used in this study. Interceptor and LifeNet bednets were kindly provided by BASF and BAYER, respectively., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Immunoassay and amperometric biosensor approaches for the detection of deltamethrin in seawater

  • Fruhmann, Philipp
  • Sanchís Villariz, Ana
  • Mayerhuber, Lisa
  • Vanka, Tünde
  • Kleber, Christoph
  • Salvador, Juan Pablo
  • Marco, María Pilar
The study of an enzyme-linked immunosorbent assay (ELISA) and an amperometric biosensor for the detection of the pyrethroid deltamethrin in seawater is reported. The preparation of specific polyclonal antibodies is addressed using two immunizing haptens based on deltamethrin and cypermethrin compounds, with a spacer arm placed at the cyano residue in the pyrethroid structure. Different conjugates based on bovine serum albumin and aminodextran are prepared depending on the lipophilic profile of the competitor haptens studied. A reproducible and sensitive indirect competitive ELISA is developed, reaching a limit of detection of 1.2 ± 0.04 μg L−1 and an IC50 value of 21.4 ± 0.3 μg L−1 (both n = 3). For validation of the assays described, artificial seawater samples fortified with deltamethrin are analyzed. For the ELISA assay, these accuracy studies reported a slope of 0.904. An amperometric immunosensor is developed using the same immunoreagents and achieving a comparable detectability in terms of LOD of 4.7 μg L−1, measuring seawater without any pretreatment. These results suggest that both techniques can be used as rapid and simple analytical methods for deltamethrin quantification in seawater samples, which are great candidates for initial environmental screening programs. © 2018, Springer-Verlag GmbH Germany, part of Springer Nature., Funding information This work has been funded by SEA-on-a-CHIP project (FP7-OCEAN-2013, no 614168). The Nb4D group (formerly Applied Molecular Receptors group, AMRg) is a consolidated research group (Grup de Recerca) of the Generalitat de Catalunya and has support from the Departament d’Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya (expedient: 2014 SGR 1484). CIBER-BBN is an initiative funded by the Spanish National Plan for Scientific and Technical Research and Innovation 2013–2016; Iniciativa Ingenio 2010, Consolider Program, and CIBER Actions are financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund. The ICTS BNANOBIOSIS,^ and particularly the Custom Antibody Service (CAbS, IQAC-CSIC, CIBER-BBN), is acknowledged for the assistance and support related to the immunoreagents used in this work., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Fluorescent microarray for multiplexed quantification of environmental contaminants in seawater samples

  • Sanchís Villariz, Ana
  • Salvador, Juan Pablo
  • Campbell, Katrina
  • Elliott, Christopher T.
  • Shelver, Weilin L.
  • Li, Qingxiao
  • Marco, María Pilar
The development of a fluorescent multiplexed microarray platform able to detect and quantify a wide variety of pollutants in seawater is reported. The microarray platform has been manufactured by spotting 6 different bioconjugate competitors and it uses a cocktail of 6 monoclonal or polyclonal antibodies raised against important families of chemical pollutants such as triazine biocide (i.e. Irgarol 1051®), sulfonamide and chloramphenicol antibiotics, polybrominated diphenyl ether flame-retardant (PBDE, i.e. BDE-47), hormone (17β-estradiol), and algae toxin (domoic acid). These contaminants were selected as model analytes, however, the platform developed has the potential to detect a broader group of compounds based on the cross-reactivity of the immunoreagents used. The microarray chip is able to simultaneously determine these families of contaminants directly in seawater samples reaching limits of detection close to the levels found in contaminated areas (Irgarol 1051® 0.19 ± 0,06 µg L−1; sulfapyridine, 0.17 ± 0.07 µg L−1; chloramphenicol, 0.11 ± 0.03 µg L−1; BDE-47, 2.71 ± 1.13 µg L−1; 17β-estradiol, 0.94 ± 0.30 µg L−1 and domoic acid, 1.71 ± 0.30 µg L−1). Performance of the multiplexed microarray chip was assessed by measuring 38 blind spiked seawater samples containing either one of these contaminants or mixtures of them. The accuracy found was very good and the coefficient of variation was < 20% in all the cases. No sample pre-treatment was necessary, and the results could be obtained in just 1 h 30 min. The microarray shows high sample throughput capabilities, being able to measure simultaneously more than 68 samples and screen them for a significant number of chemical contaminants of interest in environmental screening programs. © 2018 Elsevier B.V., This work has been funded by SEA-on-a-CHIP project (FP7-OCEAN-2013, n° 614168 ). The Nb4D group (formerly Applied Molecular Receptors group, AMRg) is a consolidated research group (Grup de Recerca) of the Generalitat de Catalunya and has support from the Departament d′Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya (expedient: 2014 SGR 1484). CIBER-BBN is an initiative funded by the Spanish National Plan for Scientific and Technical Research and Innovation 2013–2016, Iniciativa Ingenio 2010, Consolider Program, CIBER Actions are financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund. The ICTS “NANOBIOSIS”, and particularly the Custom Antibody Service (CAbS, IQAC-CSIC, CIBER-BBN), is acknowledged for the assistance and support related to the immunoreagents used in this work. Appendix A, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Multiplexed immunochemical techniques for the detection of pollutants in aquatic environments

  • Sanchís Villariz, Ana
  • Salvador, Juan Pablo
  • Marco, María Pilar
The present article gives an overview of the situation of the aquatic ecosystem in respect to contamination by chemical pollutants and the different multiplexed techniques used to detect, identify and quantify water pollutants. A brief comparison between chromatographic and immunochemical methods is described at the beginning of this article, as an introduction of the increasing interest for multidetection of pollutants in these environments. The information regarding multiplexed immunochemical and biosensors technologies is presented emphasizing all aspects, from the importance of the design of immunizing haptens and the production of antibodies with different specificity potentials, to the establishment of different approaches to fulfill the multiplexation needs the actual environmental monitoring requires. For each class of platforms described a brief description of the physical principle, specific features, and basic concepts is presented providing additionally specific examples. © 2018 Elsevier B.V., This work has been funded by the EC ( FP7-OCEAN-2013-1-614168 ). The Nb4D group is a consolidated research group (Grup de Recerca) of the Generalitat de Catalunya and has support from the Departament d’Universitats , Recerca i Societat de la Informació de la Generalitat de Catalunya (expedient: 2017 SGR 1441 ). CIBER-BBN is an initiative funded by the Spanish National Plan for Scientific and Technical Research and Innovation 2013–2016 , Iniciativa Ingenio 2010 , Consolider Program , CIBER Actions are financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund ., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Development and validation of a multianalyte immunoassay for the quantification of environmental pollutants in seawater samples from the Catalonia coastal area

  • Sanchis, Ana
  • Bosch-Orea, Cristina
  • Salvador, Juan Pablo
  • Marco, María Pilar
  • Farré, Marinella
Five different enzyme-linked immunosorbent assays (ELISAs) have been developed and applied for the detection of five representatives of important families of chemical pollutants in seawater: Irgarol 1051® (triazine biocide), sulfapyridine and chloramphenicol (antibiotics), 17β-estradiol (hormone), and domoic acid (algae toxin). The assays were validated by high-performance liquid chromatography (HPLC) coupled with high-resolution mass spectrometry (HRMS) showing good correlation between both immunochemical and chemical techniques. A process of extraction and clean-up was added prior to the analysis based on solid-phase extraction (SPE). The multianalyte platform presented good specificity for each compound and adequate sensitivity, with limits of detection (LOD) after the SPE treatment of 0.124 ± 0.006, 0.969 ± 0.09, 0.20 ± 0.05, 1.11 ± 0.012, and 1.39 ± 0.09 ng L−1 for Irgarol 1051®, sulfapyridine, chloramphenicol, 17β-estradiol, and domoic acid, respectively. No matrix effects were noticed in working with the seawater extracts. Afterward, seawater samples from the Mediterranean Sea (coastal area of Catalonia) were analyzed by both techniques and only one sample presented one contaminant, 17β-estradiol, in the concentration of 0.011 ± 0.04 μg L−1., The Nb4D group (formerly Applied Molecular Receptors group, AMRg) is a consolidated research group (Grup de Recerca) of the Generalitat de Catalunya and has support from the Departament d’Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya (expedient: 2014 SGR 1484). CIBER-BBN is an initiative funded by the Spanish National Plan for Scientific and Technical Research and Innovation 2013-2016, Iniciativa Ingenio 2010, and Consolider Program; CIBER Actions are financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund. The ICTS “NANOBIOSIS”, and particularly the Custom Antibody Service (CAbS, IQAC-CSIC, CIBER-BBN), is acknowledged for the assistance and support related to the immunoreagents used in this work.This work has been funded by SEA-on-a-CHIP project (FP7-OCEAN-2013, no. 614168)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Comprehensive study of sulfamethoxazole effects in marine mussels: Bioconcentration, enzymatic activities and metabolomics

  • Serra-Compte, Albert
  • Álvarez-Muñoz, Diana
  • Solé, Montserrat
  • Cáceres, Núria
  • Barceló, Damià
  • Rodríguez-Mozaz, Sara
11 pages, 9 figures, supplementary material https://doi.org/10.1016/j.envres.2019.03.021, Antibiotics accumulation in aquatic organisms may be of great concern from an ecological point of view but also from a human perspective, especially when they are accumulated in edible animals like marine mussels. In this work, mussels (Mytilus galloprovincialis) were exposed to sulfamethoxazole antibiotic (SMX) at 10 µg/L during 96 h, followed by 24 h of depuration. The experiment was carried out at summer and winter conditions. SMX showed a bioconcentration factor in mussel of 1.5 L/kg (dry weight) and 69% of the compound was eliminated from the organism in 24 h. The metabolomics approach revealed alterations in amino acids levels (aspartate, phenylalanine, valine and tryptophan) pinpointing disturbances in osmotic regulation and energy metabolism. Besides, the levels of some nucleotides (guanosine and inosine) and a carboxylic acid were also affected. However, SMX exposed mussels did not show any significant alteration in the enzymatic activities related to the xenobiotic metabolism and oxidative stress. Moreover, some of the changes observed in mussel's metabolites suggested alterations in mussel's organoleptic characteristics that can affect its quality as seafood commodity. Overall, our results showed that SMX exposure to marine mussels may have ecological implications by provoking sub-lethal effects to exposed organisms. Nevertheless, no risk for consumers derived from mussel ingestion is expected due to the low bioconcentration capacity of SMX and fast depuration in this seafood type, This work has received funding from SEA-on-a-CHIP project under grant agreement No.614168 from European Union's Seventh Framework Program (FP7-OCEAN-2013) and been also supported by the Spanish Ministry of Economy and Competitiveness through the PLAS-MED (CTM2017-89701-C3-2-R) and AIMCOST (CGL2016-76332-R MINECO/FEDER/UE) projects. Authors acknowledge the support from the Economy and Knowledge Department of the Catalan Government through Consolidated Research Group (ICRA-ENV 2017 SGR 1124 and 2017-SGR-1404-Water and Soil Quality Unit). Albert Serra-Compte acknowledges the FI-DGR research fellowship from the Catalan Government (2018FI_B2_00170). Sara Rodriguez-Mozaz acknowledges the Ramon y Cajal program (RYC-2014-16707) and Diana Álvarez-Muñoz the support of the project XENOMETABOLOMIC (CTM2015-73179-JIN) (AEI/FEDER/UE), Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Environmental risks associated with contaminants of legacy and emerging concern at European aquaculture areas

  • Aminot, Yann
  • Sayfritz, Stephen J.
  • Thomas, Kevin V.
  • Godinho, Lia
  • Botteon, Elena
  • Ferrari, Federico
  • Boti, Vasiliki
  • Albanis, Triantafyllos
  • Köck-Schulmeyer, Marianne
  • Diaz-Cruz, Silvia
  • Farré, Marinella
  • Barceló, Damià
  • Marques, Antonio
  • Readman, James W.
The contamination of marine ecosystems by contaminants of emerging concern such as personal care products or per- and polyfluoroalkyl substances is of increasing concern. This work assessed the concentrations of selected contaminants of emerging concern in water and sediment of European aquaculture areas, to evaluate their co-variation with legacy contaminants (polycyclic aromatic hydrocarbons) and faecal biomarkers, and estimate the risks associated with their occurrence. The 9 study sites were selected in 7 European countries to be representative of the aquaculture activities of their region: 4 sites in the Atlantic Ocean and 5 in the Mediterranean Sea. Musks, UV filters, preservatives, per- and polyfluoroalkyl substances and polycyclic aromatic hydrocarbons were detected in at least one of the sites with regional differences. While personal care products appear to be the main component of the water contamination, polycyclic aromatic hydrocarbons were mostly found in sediments. As expected, generally higher levels of personal care products were found in sewage impacted sites, urbanised coasts and estuaries. The risk assessment for water and sediment revealed a potential risk for the local aquatic environment from contaminants of both legacy and emerging concern, with a significant contribution of the UV filter octocrylene. Despite marginal contributions of per- and polyfluoroalkyl substances to the total concentrations, PFOS (perfluorooctane sulfonate) aqueous concentrations combined to its low ecotoxicity thresholds produced significant hazard quotients indicating a potential risk to the ecosystems., This study was financially supported by the SEA-on-a-CHIP project, funded from European Union Seventh Framework Programme (FP7-OCEAN-2013) under grant agreement No. 614168. Antonio Marques is supported through the FCT Investigator program (IF)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Persistent and emerging pollutants assessment on aquaculture oysters (Crassostrea gigas) from NW Portuguese coast (Ria De Aveiro)

  • Gadelha, Juliana R.
  • Rocha, Andreia Cristina S.
  • Camacho, Carolina
  • Eljarrat, Ethel
  • Peris, Andrea
  • Aminot, Yann
  • Readman, James W.
  • Boti, Vasiliki I.
  • Nannou, Christina
  • Kapsi, Margarita
  • Albanis, Triantafyllos
  • Rocha, Filipa
  • Machado, Ana
  • Bordalo, Adriano Agostinho
  • Valente, Luísa Maria Pinheiro
  • Nunes, Maria Leonor
  • Marques, Antonio
  • Almeida, C. Marisa R.
The study aim was to determine a range of relevant persistent and emerging pollutants in oysters produced in an aquaculture facility located in an important production area, to assure their safety for human consumption. Pollutants, including 16 PAHs, 3 butyltins (BTs), 29 flame retardants (FRs, including organophosphate and halogenated FRs), 35 pesticides (including 9 pyrethroid insecticides) and 13 personal care products (PCPs, including musks and UV filters), were determined in oysters' tissues collected during one year in four seasonal sampling surveys. The seasonal environmental pollution on the production site was evaluated by water and sediment analysis. Furthermore, oysters' nutritional quality was also assessed and related with the consumption of healthy seafood, showing that oysters are a rich source of protein with low fat content and with a high quality index all year around. Results showed that most analysed pollutants were not detected either in oyster tissues or in environmental matrixes (water and sediments). The few pollutants detected in oyster tissues, including both regulated and non-legislated pollutants, such as a few PAHs (fluorene, phenanthrene, anthracene, fluoranthene, pyrene and indenopyrene), FRs (TPPO, TDCPP, DCP, BDE-47, BDE-209 and Dec 602) and PCPs (galaxolide, galaxolidone, homosalate and octocrylene), were present at low levels (in the ng/g dw range) and did not represent a significant health risk to humans. The observed seasonal variations related to human activities (e.g. tourism in summer) highlights the need for environmental protection and sustainable resource exploration for safe seafood production. © 2019 Elsevier B.V., This work was supported by the Structured R&D&I Project INNOVMAR – “Innovation and Sustainability in the Management and Exploitation of Marine Resources” (ref. NORTE-01-0145-FEDER-000035) within the research line “INSEAFOOD - Innovation and valorization of seafood products: meeting local challenges and opportunities”, founded by the Northern Regional Operational Programme (NORTE2020) through the European Regional Development Fund (ERDF). This study was also supported by the SEA-on-a-CHIP project, funded from European Union Seventh Framework Programme (FP7-OCEAN-2013) under grant agreement No. 614168. This work has been also financially supported by the Generalitat de Catalunya (Consolidated Research Group 2017 SGR 01404 – Water and Soil Quality Unit). Biotage is acknowledged for providing SPE cartridges. Authors acknowledge Carlos R. Gomes for helping on multivariated analysis., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A simple membrane with the electroactive [Sulfapyridine-H]+[Co(C2B9H11)2]- f

  • Saini, Abhishek
  • Fuentes Sempere, Isabel
  • Viñas, Clara
  • Zine, Nadia
  • Bausells, Joan
  • Errachid, Abdelhamid
  • Teixidor, Francesc
The detection of a drug belonging to the Sulfonamide class of compounds, namely Sulfapyridine, is reported in this work using an in-situ and fast potentiometric method. The strategy employed for this detection is based on the novel ion pair complex, [Sulfapyridine-H]+[Co(C2B9H11)2]- acting as the active site for highly selective recognition of Sulfapyridine. This enables the sensor's selectivity to be improved by incorporating the target molecule to the selective membrane. In this work, all solid state Sulfapyridine selective microelectrodes based on PVC-type membranes were prepared using three different plasticizers and the aforementioned ion pair complex. The sensors developed have provided quick and accurate response within the range of 10−6 mol/dm3 to 10−3 mol/dm3 of Sulfapyridine concentration and showed a Nernstian slope between 47 and 61 depending upon the type of plasticizer used. The lowest limit of detection achieved was 4 μmol/dm3. The potentiometric coefficient of selectivity, KA,Bpot, has shown that the Sulfapyridine-selective microsensors were highly selective towards Sulfapyridine even when compared to other members of the Sulfonamides class of compounds. In addition, from the Reilley diagram it can be observed that the sensor signal is stable for a working pH interval between 6.00 and 8.00., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Portable flow multiplexing device for continuous, in situ biodetection of environmental contaminants

  • Salvador, Juan Pablo
  • Marco, María Pilar
  • Saviozzi, Giacomo
  • Laschi, Cecilia
  • Arreza, Fernando
  • Palacio, Francisco
  • López, Manel
A compact, low-cost and low-powered device was developed and arranged for multiplexed biodetection of sea water contaminants from continuous flow mode. Electronics, mechanics and fluidics were designed to guarantee identical functional liquid flow through eight parallel sensor microchambers during a predetermined time period providing 8 values at the same time. The accuracy and repeatability of the device was tested in-lab, achieving a deviation of less than 10% when measuring the same analyte in all the chambers. The experimental results obtained with our device were finally compared with those measured in continuous flux by a commercial potentiostat SP150 (Bio-Logic Science Instruments), obtaining identical results, which validated the proposed device., This work has been funded by funding agency EC project SEA-on-a-chip (FP7-OCEAN-2013-614168) and partially supported by the European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie agreement No 712949 (TECNIOspringPLUS) and from the Agency of Business Competitiveness of the Government of Catalonia (TECSPR18-1-0042). The Nb4D group is a consolidated research group (2017 SGR 1441)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Selective Antibody-Free Sensing Membranes for Picogram Tetracycline Detection

  • Ben Halima, Hamdi
  • Baraket, Abdoullatif
  • Viñas, Clara
  • Zine, Nadia
  • Bausells, Joan
  • Jaffrezic-Renault, Nicole
  • Teixidor, Francesc
  • Errachid, Abdelhamid
As an antibody-free sensing membrane for the detection of the antibiotic tetracycline (TC), a liquid PVC membrane doped with the ion-pair tetracycline/θ-shaped anion [3,3'-Co(1,2-C2B9H11)2]- ([o-COSAN]-) was formulated and deposited on a SWCNT modified gold microelectrode. The chosen transduction technique was electrochemical impedance spectroscopy (EIS). The PVC membrane was composed of: the tetracycline/[o-COSAN]- ion-pair, a plasticizer. A detection limit of 0.3 pg/L was obtained with this membrane, using bis(2-ethylhexyl) sebacate as a plasticizer. The sensitivity of detection of tetracycline was five times higher than that of oxytetracycline and of terramycin, and 22 times higher than that of demeclocycline. A shelf-life of the prepared sensor was more than six months and was used for detection in spiked honey samples. These results open the way to having continuous monitoring sensors with a high detection capacity, are easy to clean, avoid the use of antibodies, and produce a direct measurement., The authors acknowledge the financial support of the European Union’s Horizon 2020 research and innovation program, Project NMBP–13-2017 KardiaTool (Grant agreement No. 768686), SEA-on-a-CHIP (FP7- OCEAN-2013) under the grant agreement No. 614168. The authors acknowledge the financial support from the POC4allergies project (Grant Agreement No. 768686), which received funding from ERA PerMed ERA-NET, and the financial support from the Bionanosens project (Grant Agreement No. 9[887]), which received funding from the European Union’s Horizon 2020., With funding from the Spanish government through the ‘Severo Ochoa Centre of Excellence’ accreditation (CEX2019-000917-S)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Amperometric Biosensor for Continuous Monitoring Irgarol 1051 in Sea Water

  • Salvador, Juan Pablo
  • Marco, María Pilar
Irgarol 1051 is one of the most employed antifouling agents and is one of the most commonly found in marine environment. According to its widespread use the European Comission turned its attention on this agent as one of the priority substances that has to be controlled. The aim of this article is to develop an immunosensor for the determination of Irgarol 1051 in sea water for implementation in a flow analysis system. The transducing principle employed for its development was an amperometric detection using gold screen printed electrodes which were functionalized for the covalent immobilization of the immunoreagents. The detection of Irgarol 1051 was performed using specific antibodies working under competitive indirect format. The immunosensor was demonstrated to measure directly in sea water with high detectability, accurately and robust. The system allows consecutive measurements using the same chip owing to an easy regeneration process. The limit of detection reached was 0.15±0.09 nM (0.038±0.022 µg ⋅ L−1) measured directly in sea water., This work has been funded by SEA-on-a-chip project (FP7-OCEAN-2013-614168). The Nb4D group (formerly Applied Molecular Receptors group, AMRg) is a consolidated research group (Grup de Recerca) of the Generalitat de Catalunya and has support from the Departament d'Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya (expedient: 2014 SGR 1484). CIBER-BBN is an initiative funded by the Spanish National Plan for Scientific and Technical Research and Innovation 2013–2016, Iniciativa Ingenio 2010, Consolider Program, CIBER Actions are financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund. The ICTS “NANOBIOSIS”, and particularly the Custom Antibody Service (CAbS, IQAC-CSIC, CIBER-BBN), is acknowledged for the assistance and support related to the immunoreagents used in this work., Peer reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Comprehensive study of sulfamethoxazole effects in marine mussels: bioconcentration, enzymatic activities and metabolomics

  • Serra Compte, Albert
  • Álvarez Muñoz, Diana
  • Solé, Montserrat
  • Cáceres, Núria
  • Barceló i Cullerés, Damià
  • Rodríguez Mozaz, Sara
Antibiotics accumulation in aquatic organisms may be of great concern from an ecological point of view but also from a human perspective, especially when they are accumulated in edible animals like marine mussels. In this work, mussels (Mytilus galloprovincialis) were exposed to sulfamethoxazole antibiotic (SMX) at 10 µg/L during 96 h, followed by 24 h of depuration. The experiment was carried out at summer and winter conditions. SMX showed a bioconcentration factor in mussel of 1.5 L/Kg (dry weight) and 69% of the compound was eliminated from the organism in 24 h. The metabolomics approach revealed alterations in amino acids levels (aspartate, phenylalanine, valine and tryptophan) pinpointing disturbances in osmotic regulation and energy metabolism. Besides, the levels of some nucleotides (guanosine and inosine) and a carboxylic acid were also affected. However, SMX exposed mussels did not show any significant alteration in the enzymatic activities related to the xenobiotic metabolism and oxidative stress. Moreover, some of the changes observed in mussel’s metabolites suggested alterations in mussel’s organoleptic characteristics that can affect its quality as seafood commodity. Overall, our results showed that SMX exposure to marine mussels may have ecological implications by provoking sub-lethal effects to exposed organisms. Nevertheless, no risk for consumers derived from mussel ingestion is expected due to the low bioconcentration capacity of SMX and fast depuration in this seafood type, This work has received funding from SEA-on-a-CHIP project under grant agreement No.614168 from European Union's Seventh Framework Program (FP7-OCEAN-2013) and been also supported by the Spanish Ministry of Economy and Competitiveness through the PLAS-MED (CTM2017-89701-C3-2-R) and AIMCOST (CGL2016-76332-R MINECO/FEDER/UE) projects. Authors acknowledge the support from the Economy and Knowledge Department of the Catalan Government through Consolidated Research Group (ICRA-ENV 2017 SGR 1124 and 2017-SGR-1404-Water and Soil Quality Unit). Albert Serra-Compte acknowledges the FI-DGR research fellowship from the Catalan Government (2018FI_B2_00170). Sara Rodriguez-Mozaz acknowledges the Ramon y Cajal program (RYC-2014-16707) and Diana Álvarez-Muñoz the support of the project XENOMETABOLOMIC (CTM2015-73179-JIN) (AEI/FEDER/UE)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Multi-residue method for the determination of antibiotics and some of their metabolites in seafood

  • Serra Compte, Albert
  • Álvarez Muñoz, Diana
  • Rodríguez Mozaz, Sara
  • Barceló i Cullerés, Damià
El títol de la versió postprint d'aquest article és: 'Fast methodology for the determination of a broad set of antibiotics and some of their metabolites in seafood', The presence of antibiotics in seafood for human consumption may pose a risk for consumers. A methodology for the analysis of antibiotics in seafood based on QuEChERS (quick, easy, cheap, effective, rugged, and safe) extraction, followed by detection and quantification using liquid chromatography coupled to mass spectrometry was developed. The analytical method was evaluated for the determination of 23 antibiotics (including parent compounds and some metabolites) in fish, mussels and clams. Recoveries ranged between 30% and 70% for most of the compounds and method detection and quantification limits (MDLs and MQLs) were between 0.01 and 0.31 ng/g dry weigh (dw) and 0.02–1.03 ng/g (dw) respectively. Real seafood samples were analysed using this method. Nine antibiotics were found at levels above MDLs; however none of them exceed the maximum residue limits (MRL) established by the authorities. Tetracycline was the most ubiquitous compound, presenting also the highest concentration: 5.63 ng/g (dw) in fish from Netherlands. In addition, an alternative technique based on microbial growth inhibition was explored as semiquantitative detection method of antibiotics in seafood. This methodology c ould be applied as a fast screening technique for the detection of macrolides and β-lactams in seafood but further research is needed for other antibiotics families, The research leading to these results has received funding from the European Union Seventh Framework Programme (FP7/2007-2013) under the ECsafeSEAFOOD project (grant agreement n° 311820) and the SEA-on-a-CHIP project (grant agreement no. 614168). It has been co-financed by the European Union through the European Regional Development Fund (ERDF). This work has also been partly funded by the Generalitat de Catalunya (Consolidated Research Groups 2014-SGR-291-Catalan Institute for Water Research 2014 & 2014-SGR-418-Water and Soil Quality Unit)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization

  • Pruna Morales, Raquel
  • Palacio Bonet, Francisco
  • Baraket, Abdoullatif
  • Bausells, Joan
  • Errachid, Abdelhamid
  • López de Miguel, Manuel
The development of miniaturized potentiostats capable of measuring in a wide range of conditions and with full characteristics (e.g., wide bandwidth and capacitive/inductive contribution to sensor's impedance) is still an unresolved challenge in bioelectronics. We present a simple analogue design coupled to a digital filter based on a lock-in amplifier as an alternative to complex architectures reported hitherto. A low-cost, miniaturized and fully integrated acquisition electronic system was developed, tested for a fully integrated three-lead electrochemical biosensor and benchmarked against a commercial potentiostat. The portable potentiostat was coupled to an array of miniaturized gold working electrodes to perform complex impedance analyses for tumor necrosis factor α (TNF-α) cytokine detection. This wearable potentiostat is very promising for the development of low-cost point-of-care (POC) with low power consumption.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Portable flow multiplexing device for continuous, in situ biodetection of environmental contaminants

  • Salvador Vico, Juan Pablo
  • Marco Colás, Ma. Pilar
  • Saviozzi, Giacomo
  • Laschi, Cecilia
  • Arreza Martín, Fernando Jesús
  • Palacio Bonet, Francisco
  • López de Miguel, Manuel
A compact, low-cost and low-powered device was developed and arranged for multiplexed biodetection of sea water contaminants from continuous flow mode. Electronics, mechanics and fluidics were designed to guarantee identical functional liquid flow through eight parallel sensor microchambers during a predetermined time period providing 8 values at the same time. The accuracy and repeatability of the device was tested in-lab, achieving a deviation of less than 10% when measuring the same analyte in all the chambers. The experimental results obtained with our device were finally compared with those measured in continuous flux by a commercial potentiostat SP150 (Bio-Logic Science Instruments), obtaining identical results, which validated the proposed device.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Large area in situ fabrication of Poly(pyrrole)-nanowires on flexible thermoplastic films using Nanocontact printing

  • Garcia-Cruz, Álvaro
  • Lee, Michael
  • Marote, Pedro
  • Zine, Nadia
  • Sigaud, Monique
  • Bonhomme, Anne
  • Pruna Morales, Raquel
  • López de Miguel, Manuel
  • Bausells, Joan
  • Jaffrezic, Nicole
  • Errachid, Abdelhamid
Abstract: Highly efficient nano-engineering tools will certainly revolutionize the biomedical and sensing devices research and development in the years to come. Here, we present a novel high performance conducting poly(pyrrole) nanowires (PPy-NW) patterning technology on thermoplastic surfaces (poly(ethylene terephthalate (PETE), poly(ethylene 2,6-naphthalate (PEN), polyimide (PI), and cyclic olefin copolymer (COC)) using nanocontact printing and controlled chemical polymerization (nCP-CCP) technique. The technique uses a commercial compact disk (CD) as a template to produce nanopatterned polydimethylsiloxane (PDMS) stamps. The PDMS nanopatterned stamp was applied to print the PPy-NWs and the developed technology of nCP-CCP produced 3D conducting nanostructures. This new and very promising nanopatterning technology was achieved in a single step and with a low cost of fabrication over large areas.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Characterization of linear-mode avalanche photodiodes in standard CMOS

  • Vilella Figueras, Eva
  • Vilà i Arbonès, Anna Maria
  • Palacio, Fernando
  • López de Miguel, Manuel
  • Diéguez Barrientos, Àngel
Linear-mode Avalanche PhotoDiodes (APDs) can be fabricated in standard CMOS processes for obtaining high multiplication gains that allow to determine the number of incident photons with great precision. This idea can be exploited in several application domains, such as image sensors, optical communications and quantum information. In this work, we present a linear-mode APD fabricated in a 0.35 µm CMOS process and report its noise and gain characterization by means of two different experimental set-ups. Good matching is observed between the results obtained by means of the two different methods.