ROMPIENDO LAS BARRERAS DE LA ESPECTROMETRIA ATOMICA. DESARROLLO DE METODOS BASADOS EN LA MEDIDA DE ESPECIES MOLECULARES PARA EL ANALISIS ELEMENTAL E ISOTOPICO

CTQ2015-64684-P

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de Fomento de la Investigación Científica y Técnica de Excelencia
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D (Excelencia / Generación de Conocimiento)
Call year 2015
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 14
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publication Otros (Other)

Analysis of whole blood by ICP-MS equipped with a high temperature total sample consumption system

  • Cañabate López, Águeda
  • García-Ruiz, Esperanza
  • Resano, Martín
  • Todolí Torró, José Luis
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
In this work, the performance of a high temperature torch Integrated Sample Introduction System (hTISIS) using inductively coupled plasma mass spectrometry (ICP-MS) for the multi-element analysis of whole blood is evaluated. Two different quadrupole-based spectrometers were tested and the optimization studies were performed with a reference whole blood material. Sample dilution factor and hTISIS temperature were taken as the variables. The sample was introduced following two different procedures: continuous aspiration and air-segmentation. The optimum performance of the system in terms of both analytical figures of merit and accuracy was obtained for a hTISIS temperature of 200 °C and for either 1 : 10 or 1 : 25 dilution factors depending on the ICP-MS device used. An improvement in terms of sensitivity and detection limits was obtained with the hTISIS as compared to the conventional cyclonic spray chamber. Thus, for 1 : 25 diluted blood samples, the hTISIS improved the sensitivity by a factor ranging 2.0–4.5. Moreover, at 200 °C, the limits of detection for hTISIS at 200 °C were 1.1 to 8.4 times lower than those for the cyclonic spray chamber. This analytical parameter was in the ng L−1 range for the detected elements. Matrix effects in turn became less severe as the hTISIS temperature increased (from room temperature to 80 °C). All these results were obtained without a severe degradation of the fundamental plasma parameters. In fact, under optimum conditions BaO+/Ba+ and Ba2+/Ba+ signal ratios were 1.2% and 2.0%, respectively. The developed method was applied for the analysis of low volumes (ca. 2.5 μL) of real blood samples after a minimally invasive collection by volumetric absorptive microsampling. The hTISIS is an easy-to-implement sample introduction system that can be employed for the routine analysis using ICP-MS.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

A sustainable and simple energy dispersive X-ray fluorescence method for sulfur determination at trace levels in biodiesel samples via formation of biodiesel spots on a suitable solid support

  • Marguí, Eva
  • Resano, Martín
  • Queralt Mitjans, Ignacio
The aim of the present work is the development of a simple, sensitive and sustainable EDXRF method for the determination of trace amounts of sulfur in biodiesel samples. In this method, the deposition of several microliters of sample onto an organic thin layer and the analysis of the resulting adsorbed biodiesel spot by benchtop EDXRF is proposed. A careful study was performed to select the volume and the best solid support to deposit biodiesel samples, including filters made of different materials (glass fiber, Nylon, cellulose, paper) and a commercial disposable absorbent pad (UltraCarry, Rigaku). A critical issue that limits the use of most of these solid supports was the relative high blank signals that hamper the determination of sulfur at trace levels. Finally, it was found that best strategy was the deposition of 50 μL of biodiesel on the UltraCarry sample retainer. Operating conditions for EDXRF measurements were also evaluated to obtain the best instrumental sensitivity for sulfur determination (Excitation: 20 kV, no primary filter, measurement time: 300 s). Using the best analytical conditions the quantification limit of the method was 7 mg kg−1 of sulfur. This value is even better than the one reported in the ASTM D4294 method (LOQ: 16.0 mg kg−1) but using a sample amount 100 times smaller. The linearity was confirmed in the range of 10–100 mg kg−1by analyzing a set of commercial biodiesel standards. Accuracy and precision of the results, evaluated by the analysis of samples prepared with the same matrix as the standards, with levels of 20, 40 and 75 mg kg−1of sulfur, and processed as unknowns, proved acceptable (Recoveries: 94.3–110.6%, RSD: 10.8–13.6%, n = 3) for the intended purpose. Overall, the performance of the method developed is promising and it could be used to determine trace amounts of sulfur in biodiesel samples in a simple, sustainable and cost-effective way. Furthermore, since the original sample is adsorbed onto a solid support, repeat confirmatory analyses on the same specimen, if needed, can be carried out. © 2019 Elsevier B.V., MR acknowledges the funding obtained via CTQ2015-64684P (MINECO/FEDER) and from the Aragón Government (Fondo Social Europeo). Authors would like to acknowledge to Mr. Arnau Ortiz for his contribution on the performance of the experimental work., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Analysis of whole blood by ICP-MS equipped with a high temperature total sample consumption system

  • Cañabate, Águeda
  • García-Ruiz, Esperanza
  • Resano, Martín
  • Todolí, José Luis
In this work, the performance of a high temperature torch Integrated Sample Introduction System (hTISIS) using inductively coupled plasma mass spectrometry (ICP-MS) for the multi-element analysis of whole blood is evaluated. Two different quadrupole-based spectrometers were tested and the optimization studies were performed with a reference whole blood material. Sample dilution factor and hTISIS temperature were taken as the variables. The sample was introduced following two different procedures: continuous aspiration and air-segmentation. The optimum performance of the system in terms of both analytical figures of merit and accuracy was obtained for a hTISIS temperature of 200 °C and for either 1 : 10 or 1 : 25 dilution factors depending on the ICP-MS device used. An improvement in terms of sensitivity and detection limits was obtained with the hTISIS as compared to the conventional cyclonic spray chamber. Thus, for 1 : 25 diluted blood samples, the hTISIS improved the sensitivity by a factor ranging 2.0-4.5. Moreover, at 200 °C, the limits of detection for hTISIS at 200 °C were 1.1 to 8.4 times lower than those for the cyclonic spray chamber. This analytical parameter was in the ng L-1 range for the detected elements. Matrix effects in turn became less severe as the hTISIS temperature increased (from room temperature to 80 °C). All these results were obtained without a severe degradation of the fundamental plasma parameters. In fact, under optimum conditions BaO+/Ba+ and Ba2+/Ba+ signal ratios were 1.2% and 2.0%, respectively. The developed method was applied for the analysis of low volumes (ca. 2.5 µL) of real blood samples after a minimally invasive collection by volumetric absorptive microsampling. The hTISIS is an easy-to-implement sample introduction system that can be employed for the routine analysis using ICP-MS.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Detecting paraprotein interference on a direct bilirubin assay by reviewing the photometric reaction data

  • García-González, Elena
  • Aramendía, Maite
  • González-Tarancón, Ricardo
  • Romero-Sánchez, Naiara
  • Rello, Luis
The direct bilirubin (D-Bil) assay on the AU Beckman Coulter instrumentation can be interfered by paraproteins, which may result in spurious D-Bil results. In a previous work, we took advantage of this fact to detect this interference, thus helping with the identification of patients with unsuspected monoclonal gammopathies. In this work, we investigate the possibility to detect interference based on the review of the photometric reactions, regardless of the D-Bil result. The D-Bil assay was carried out in a set of 2164 samples. It included a group of 164 samples with paraproteins (67 of which caused interference on the assay), as well as different groups of samples for which high absorbance background readings could also be expected (i.e. hemolyzed, lipemic, or icteric samples). Photometric reaction data were reviewed and receiver operating characteristics (ROC) curves were used to establish a cut-off for absorbance that best discriminates interference. The best cut-off was 0.0100 for the absorbance at the first photometric point of the complementary wavelength in the blank cuvette. Once the optimal cut-off for probable interference was selected, all samples analyzed in our laboratory that provided absorbance values above this cut-off were further investigated to try to discover paraproteins. During a period of 6 months, we detected 44 samples containing paraproteins, five of which belonged to patients with non-diagnosed monoclonal gammopathies. Review of the photometric reaction data permits the systematic detection of paraprotein interference on the D-Bil AU assay, even for samples for which reasonable results are obtained.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Characterization of SiO2 nanoparticles by single particle-inductively coupled plasma-tandem mass spectrometry (SP-ICP-MS/MS)

  • Bolea-Fernandez, E.
  • Leite, D.
  • Rua-Ibarz, A.
  • Balcaen, L.
  • Aramendía, M.
  • Resano, M.
  • Vanhaecke, F.
The increase in the use of SiO2 nanoparticles (NPs) is raising concern about their environmental and health effects, thus necessitating the development of novel methods for their straightforward detection and characterization. Single particle ICP-mass spectrometry (SP-ICP-MS) is able to provide information on the size of NPs, their particle number density and mass concentration. However, the determination of Si via ICP-MS is strongly hampered by the occurrence of spectral overlap from polyatomic species (e.g., CO+ and N2+). The use of tandem ICP-MS (ICP-MS/MS) enables interference-free conditions to be obtained, even in the most demanding applications. Upon testing several gases, the use of CH3F (monitoring of SiF+, mass-shift approach) and of H2 (monitoring of Si+, on-mass approach) were demonstrated to be the most suitable to overcome the spectral interference affecting ultra-trace Si determination (LoD < 15 ng L-1). By using these approaches, SiO2 NPs (ranging between 80 and 400 nm) can be detected and characterized. For SiO2 NPs > 100 nm, it was possible to provide accurate results in a straightforward way, as the signals they give rise to are well resolved from those of the background. In the case of 80 and 100 nm NPs, the use of a simple deconvolution approach following a Gaussian model was needed to characterize SiO2 NPs apparently showing incomplete distributions as a result of the presence of the background signal. Overall, the methods developed using SP-ICP-MS/MS are sensitive and selective enough for the interference-free determination of Si at ultra-trace levels, also in the form of SiO2 NPs.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Reseña (Review)

Dried matrix spots and clinical elemental analysis. Current status, difficulties, and opportunities

  • Resano, M.
  • Belarra, M.A.
  • García-Ruiz, E.
  • Aramendía, M.
  • Rello, L.
This article examines the increasing importance of dried matrix spots (DMS), such as dried blood spots, dried urine spots, etc., in biomedical research, the challenges associated with their analysis when quantitative elemental information is aimed at, as well as the benefits deriving from the further usage of these types of samples. The article briefly reviews the historical evolution of this sampling approach in elemental clinical analysis, stressing prospective areas of applications (e.g., newborns or prosthesis control), the methodologies most recently developed to produce DMS of known volume, as well as novel strategies proposed to analyze them, often related to direct solid sampling techniques or fast lixiviation methods. Finally, the article discusses the type of information that could be obtained after isotopic analysis of DMS when targeting non-traditional stable isotopes (e.g., Cu, Fe or Zn), which can significantly help in the early diagnosis of some medical conditions (e.g. Wilson's disease).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Determination of chlorine via the CaCl molecule by high-resolution continuum source graphite furnace molecular absorption spectrometry and direct solid sample analysis

  • Guarda, Ananda
  • Aramendía, Maite
  • Andrés, Irene
  • García-Ruiz, Esperanza
  • do Nascimento, Paulo Cicero
  • Resano, Martín
This work investigates the possibilities of high-resolution continuum source graphite furnace molecular absorption spectrometry for the direct determination of Cl in solid samples via the CaCl molecule and measurement of its molecular absorption. The method proposed is based on addition of 400 µg Ca as molecule-forming reagent and of 20 µg Pd as chemical modifier, which helps to stabilize the analyte and enhances sensitivity. The molecular spectrum for CaCl offers different lines with different limits of detection and linear ranges, which permitted to analyze solid samples with different Cl contents. The lowest limit of detection (0.75 ng Cl, corresponding to 0.75 µg g-1 for a typical sample mass of 1 mg) could be achieved by combination of three of the most sensitive lines in the vicinity of 620.862 nm, while the amplest linear range (up to 860 ng Cl) was achieved by selection of the less sensitive line at 377.501 nm. The method developed enabled the direct determination of Cl in solid samples using simple external calibration with aqueous standards. Good precision (5–9% RSD) and accuracy was attained in a series of certified samples of very different nature (i.e. coal, iron oxide, polyethylene, human hair, pine needles, rice flour and milk) and with very different Cl contents, ranging from about 50 µg g-1 to 1% (w/w) Cl. The method appears as particularly useful for Cl determination in samples with elevated Ca contents, for which biased results with other diatomic molecules, such as AlCl or SrCl, may be obtained.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Reseña (Review)

Quo vadis high-resolution continuum source atomic/molecular absorption spectrometry?

  • Resano, M.
  • García-Ruiz, E.
  • Aramendía, M.
  • Belarra, M.A.
After more than a decade since its commercial introduction, high-resolution continuum source atomic/molecular absorption spectrometry may be facing a mid-life crisis. Certainly, it is no longer a novel technique full of unknown potential, so it would already be time to establish the fields for which it is most suitable. This is, however, not so simple for a number of reasons. In the first place, more than a technique what we are discussing herein is a type of instrumentation with the potential to use two different techniques (atomic or molecular absorption), making it somewhat unique. Furthermore, the two techniques have not been explored equally, and more research on the mechanisms of formation of diatomic molecules is clearly needed. In the second place, new possibilities have recently appeared in the literature that need to be weighed as well. And there is the still unfulfilled, but nowadays more technically feasible than ever, promise to significantly increase the multi-elemental capabilities. This review critically examines the main research areas currently explored (namely, (i) direct analysis of solids and complex liquid materials, and (ii) determination of non-metals at trace levels via monitoring of molecular species) as well as the new venues (specifically, (i) isotopic analysis via monitoring of molecular species, and (ii) selective detection, quantification and sizing of nanoparticles) while also considering new instrumental developments, in an attempt to properly place high-resolution continuum source atomic/molecular absorption spectrometry in the field of trace element and isotopic analysis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A sustainable and simple energy dispersive X-ray fluorescence method for sulfur determination at trace levels in biodiesel samples via formation of biodiesel spots on a suitable solid support

  • Marguí, E.
  • Resano, M.
  • Queralt, I.
The aim of the present work is the development of a simple, sensitive and sustainable EDXRF method for the determination of trace amounts of sulfur in biodiesel samples. In this method, the deposition of several microliters of sample onto an organic thin layer and the analysis of the resulting adsorbed biodiesel spot by benchtop EDXRF is proposed. A careful study was performed to select the volume and the best solid support to deposit biodiesel samples, including filters made of different materials (glass fiber, Nylon, cellulose, paper) and a commercial disposable absorbent pad (UltraCarry, Rigaku). A critical issue that limits the use of most of these solid supports was the relative high blank signals that hamper the determination of sulfur at trace levels. Finally, it was found that best strategy was the deposition of 50 µL of biodiesel on the UltraCarry sample retainer. Operating conditions for EDXRF measurements were also evaluated to obtain the best instrumental sensitivity for sulfur determination (Excitation: 20 kV, no primary filter, measurement time: 300 s). Using the best analytical conditions the quantification limit of the method was 7 mg kg -1 of sulfur. This value is even better than the one reported in the ASTM D4294 method (LOQ: 16.0 mg kg -1 ) but using a sample amount 100 times smaller. The linearity was confirmed in the range of 10–100 mg kg -1 by analyzing a set of commercial biodiesel standards. Accuracy and precision of the results, evaluated by the analysis of samples prepared with the same matrix as the standards, with levels of 20, 40 and 75 mg kg -1 of sulfur, and processed as unknowns, proved acceptable (Recoveries: 94.3–110.6%, RSD: 10.8–13.6%, n = 3) for the intended purpose. Overall, the performance of the method developed is promising and it could be used to determine trace amounts of sulfur in biodiesel samples in a simple, sustainable and cost-effective way. Furthermore, since the original sample is adsorbed onto a solid support, repeat confirmatory analyses on the same specimen, if needed, can be carried out.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

On the effect of using collision/reaction cell (CRC) technology in single-particle ICP-mass spectrometry (SP-ICP-MS)

  • Bolea-Fernández, Eduardo
  • Leite, Diego
  • Rua-Ibarz, Ana
  • Liu, Tong
  • Woods, Glenn
  • Aramendia Marzo, Maite
  • Resano, Martín
  • Vanhaecke, Frank
In this work, the effects of using collision/reaction cell (CRC) technology in quadrupole-based ICP-MS (ICP-QMS) instrumentation operated in single-particle (SP) mode have been assessed. The influence of (i) various CRC gases, (ii) gas flow rates, (iii) nanoparticle (NP) sizes and (iv) NP types was evaluated using Ag, Au and Pt NPs with both a traditional ICP-QMS instrument and a tandem ICP-mass spectrometer. It has been shown that using CRC technology brings about a significant increase in the NP signal peak width (from 0.5 up to 6¿ms). This effect is more prominent for a heavier gas (e.g., NH3) than for a lighter one (e.g., H2 or He). At a higher gas flow rate and/or for larger particle sizes >100¿nm), the NP signal duration was prolonged to a larger extent. This effect of using CRC technology has been further demonstrated by characterizing custom-made 50 and 200¿nm Fe3O4 NPs (originally strongly affected by the occurrence of spectral overlap) using different CRC approaches (H2 on-mass and NH3 mass-shift). The use of NH3 (monitoring of Fe as the Fe(NH3)2+ reaction product ion at m/z¿=¿90 amu) induces a significant peak broadening compared to that observed when using H2 (6.10¿±¿1.60 vs. 0.94¿±¿0.49¿ms). This extension of transit time can most likely be attributed to the collisions/interactions of the ion cloud generated by a single NP event with the CRC gas and it even precludes 50¿nm Fe3O4 NPs to be detected when using the NH3 mass-shift approach. Based on these results, the influence of a longer peak width on the accuracy of SP-ICP-MS measurement data (NP size, particle number density and mass concentration) must be taken into account when using CRC technology as a means to overcome spectral overlap. To mitigate the potential detrimental effect of using CRC technology in the characterization of NPs via SP-ICP-MS(/MS), the use of light gases and low gas flow rates is recommended.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Reseña (Review)

Breaking the boundaries in spectrometry. Molecular analysis with atomic spectrometric techniques

  • Resano, M.
  • Aramendía, M.
  • Nakadi, F.V.
  • García-Ruiz, E.
  • Alvarez-Llamas, C.
  • Bordel, N.
  • Pisonero, J.
  • Bolea-Fernández, E.
  • Liu, T.
  • Vanhaecke, F.
Since the development of atomic spectrometry, trace element and isotopic analysis has been mainly based on the monitoring of atomic spectra and monoionic species. However, according to the literature and considering the current instrumental developments, it seems that some of the remaining challenges in this field can be mitigated via the measurement of molecular spectra or of polyatomic ions. This review discusses recent advances in three of the most important atomic techniques (laser-induced breakdown spectrometry, high-resolution continuum source atomic absorption spectrometry and inductively coupled plasma mass spectrometry) and how the monitoring of such molecules or polyatomic ions containing the target analyte enables attaining better selectivity and opens new ways to determine non-metals and to obtain isotopic information.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Introducing multi-energy ratios as an alternative to multi-energy calibration for Br determination: Via high-resolution continuum source graphite furnace molecular absorption spectrometry. A case study

  • Garde, Raúl
  • Venancio Nakadi, Flávio
  • García-Ruiz, Esperanza
  • Resano, Martín
This manuscript explores the advantages of using multi-signal calibration approaches for the determination of non-metals via high-resolution continuum source graphite furnace molecular absorption spectrometry (HR CS GFMAS), targeting Br as an example. Besides multi-energy calibration (MEC), a novel approach deriving from it, multi-energy ratios (MER), is introduced and compared under different conditions. This approach makes use of the same data but in a different way, such that no linear regression is performed; instead, ratios are calculated. This article investigates the potential errors deriving from the use of amounts of spike dissimilar from the sample content, leading to too high (close to 1) or too low (close to 0) slopes/ratios, setting the best conditions in terms of precision and accuracy for the intended determination in the range of approx. 0.5 to 0.6. Also, situations where the use of MER could be recommended over MEC are identified: namely when only a few transitions of sufficient sensitivity and free from overlaps are available or else, many transitions but of similar sensitivity, which may occur when HR CS GFMAS is deployed. Otherwise, for multiple transitions covering a wider sensitivity range, use of linear regression and thus, of MEC, seems favoured, as a better precision can be achieved. The calculation of limits of detection and quantification for both approaches is also discussed. It is finally further demonstrated that these multi-signal strategies help in solving chemical interferences, which very often hamper the determination of non-metals with HR CS GFMAS, and they do so in a simple way, without the need for laborious work or for the preparation of several standards and sample aliquots, therefore making them a very intriguing option when this technique is deployed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

An insight into the determination of size and number concentration of silver nanoparticles in blood using single particle ICP-MS (spICP-MS): Feasibility of application to samples relevant to: In vivo toxicology studies

  • Abad-Alvaro I.
  • Leite D.
  • Bartczak D.
  • Cuello-Nunez S.
  • Gomez-Gomez B.
  • Madrid Y.
  • Aramendia M.
  • Resano M.
  • Goenaga-Infante H.
Toxicological studies concerning nanomaterials in complex biological matrices usually require a carefully designed workflow that involves handling, transportation and preparation of a large number of samples without affecting the nanoparticle (NP) characteristics, as well as measurement methods that enable their reliable characterisation. This work describes method development for the determination of number concentration and size of silver nanoparticles (AgNP) in blood for the purpose of application to the typical workflow of an in vivo toxicology assessment involving blood-containing AgNP and Ag(i) leached out from medical devices. A systematic comparison of single particle detection using millisecond versus microsecond dwell times in the presence of different ionic Ag [Ag(i)]-to-AgNP ratios by spICP-MS was undertaken to achieve sufficient selectivity for the determination of NP number concentration. This was achieved for the first time in a complex media such as 2.5% tetramethylammonium hydroxide (TMAH)/0.1% Triton X-100 (v/v) diluent, which was proven to preserve nanoparticle stability upon 8 days of storage following AgNP quantitative extraction from the blood matrix. The potential of microsecond dwell time for improved discrimination of AgNP (40 nm) from Ag(i) was demonstrated for ionic to nanoparticle ratios [Ag(i)/AgNP] of up to 106-fold. For NP sizing, a systematic study of the impact of matrix-matched ionic calibration on the derived particle size by spICP-MS is also described. Three different ionic calibration media including 1% HNO3 (v/v), 1 mM trisodium citrate and 2.5% TMAH/0.1% Triton X-100 (v/v) were tested. Student t-test evidenced statistically significant differences between the slope of the calibration curve of Ag(i) in TMAH/Triton X-100 compared to HNO3 and trisodium citrate matrices, whereas no significant differences were found between the two latter media. Moreover, a good agreement was found between the particle diameter derived from spICP-MS following ionic calibration in TMAH/Triton X-100 and the diameter obtained with transmission electron microscopy (TEM), demonstrating the importance of matrix-matched calibration for NP size determination in a complex matrix using spICP-MS. Number concentration recovery measurements on blood samples spiked with AgNP and size measurements both using spICP-MS demonstrated the feasibility of the methodology developed here for potential future application to AgNP characterisation in toxicology research. © The Royal Society of Chemistry.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Determination of ultra-trace amounts of prosthesis-related metals in whole blood using volumetric absorptive micro-sampling and tandem ICP – Mass spectrometry

  • Bolea-Fernandez, E.
  • Phan, K.
  • Balcaen, L.
  • Resano, M.
  • Vanhaecke, F.
This paper reports on an evaluation of the suitability of a novel sample collection approach, volumetric absorptive micro-sampling (VAMS), in the context of the determination of ultra-trace concentrations of prosthesis-related metals (Al, Ti, V, Co, Cr, Ni, Sr and Zr) in whole blood. In a first phase, a simple dilute-and-shoot approach (100-fold dilution) followed by tandem ICP – mass spectrometry (ICP-MS/MS) analysis was developed for the accurate and sensitive determination of the target elements. The ICP-MS/MS method relies on the use of mass shift reactions proceeding when pressurizing the collision/reaction cell (CRC) with CH3F/He for dealing with spectral overlap. Limits of detection (LoDs) between 0.3 and 30 ng L-1 were attained in a multi-element approach. The accuracy of the method was demonstrated via successful analysis of the reference materials Seronorm Whole Blood Levels 1 and 3, and real venous blood samples, spiked with the target elements at different concentration levels (5–50 µg L-1). Although the implementation of VAMS devices introduced contamination problems for Al, Cr and Ni, VAMS followed by ICP-MS/MS analysis shows potential for future real-life routine applications when assessing levels of Ti, V, Co, Sr and/or Zr.