MODULANDO LA ESCALA DEL TIEMPO EN ESPECTROMETRIA ATOMICA PARA LA NANO-CUANTIFICACION

PGC2018-093753-B-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de Generación de Conocimiento y Fortalecimiento Científico y Tecnológico del Sistema de I+D+i
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de I+D (Excelencia / Generación de Conocimiento)
Call year 2018
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE ZARAGOZA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 10
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

On the effect of using collision/reaction cell (CRC) technology in single-particle ICP-mass spectrometry (SP-ICP-MS)

  • Bolea-Fernández, Eduardo
  • Leite, Diego
  • Rua-Ibarz, Ana
  • Liu, Tong
  • Woods, Glenn
  • Aramendia Marzo, Maite
  • Resano, Martín
  • Vanhaecke, Frank
In this work, the effects of using collision/reaction cell (CRC) technology in quadrupole-based ICP-MS (ICP-QMS) instrumentation operated in single-particle (SP) mode have been assessed. The influence of (i) various CRC gases, (ii) gas flow rates, (iii) nanoparticle (NP) sizes and (iv) NP types was evaluated using Ag, Au and Pt NPs with both a traditional ICP-QMS instrument and a tandem ICP-mass spectrometer. It has been shown that using CRC technology brings about a significant increase in the NP signal peak width (from 0.5 up to 6¿ms). This effect is more prominent for a heavier gas (e.g., NH3) than for a lighter one (e.g., H2 or He). At a higher gas flow rate and/or for larger particle sizes >100¿nm), the NP signal duration was prolonged to a larger extent. This effect of using CRC technology has been further demonstrated by characterizing custom-made 50 and 200¿nm Fe3O4 NPs (originally strongly affected by the occurrence of spectral overlap) using different CRC approaches (H2 on-mass and NH3 mass-shift). The use of NH3 (monitoring of Fe as the Fe(NH3)2+ reaction product ion at m/z¿=¿90 amu) induces a significant peak broadening compared to that observed when using H2 (6.10¿±¿1.60 vs. 0.94¿±¿0.49¿ms). This extension of transit time can most likely be attributed to the collisions/interactions of the ion cloud generated by a single NP event with the CRC gas and it even precludes 50¿nm Fe3O4 NPs to be detected when using the NH3 mass-shift approach. Based on these results, the influence of a longer peak width on the accuracy of SP-ICP-MS measurement data (NP size, particle number density and mass concentration) must be taken into account when using CRC technology as a means to overcome spectral overlap. To mitigate the potential detrimental effect of using CRC technology in the characterization of NPs via SP-ICP-MS(/MS), the use of light gases and low gas flow rates is recommended.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Reseña (Review)

Breaking the boundaries in spectrometry. Molecular analysis with atomic spectrometric techniques

  • Resano, M.
  • Aramendía, M.
  • Nakadi, F.V.
  • García-Ruiz, E.
  • Alvarez-Llamas, C.
  • Bordel, N.
  • Pisonero, J.
  • Bolea-Fernández, E.
  • Liu, T.
  • Vanhaecke, F.
Since the development of atomic spectrometry, trace element and isotopic analysis has been mainly based on the monitoring of atomic spectra and monoionic species. However, according to the literature and considering the current instrumental developments, it seems that some of the remaining challenges in this field can be mitigated via the measurement of molecular spectra or of polyatomic ions. This review discusses recent advances in three of the most important atomic techniques (laser-induced breakdown spectrometry, high-resolution continuum source atomic absorption spectrometry and inductively coupled plasma mass spectrometry) and how the monitoring of such molecules or polyatomic ions containing the target analyte enables attaining better selectivity and opens new ways to determine non-metals and to obtain isotopic information.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Introducing multi-energy ratios as an alternative to multi-energy calibration for Br determination: Via high-resolution continuum source graphite furnace molecular absorption spectrometry. A case study

  • Garde, Raúl
  • Venancio Nakadi, Flávio
  • García-Ruiz, Esperanza
  • Resano, Martín
This manuscript explores the advantages of using multi-signal calibration approaches for the determination of non-metals via high-resolution continuum source graphite furnace molecular absorption spectrometry (HR CS GFMAS), targeting Br as an example. Besides multi-energy calibration (MEC), a novel approach deriving from it, multi-energy ratios (MER), is introduced and compared under different conditions. This approach makes use of the same data but in a different way, such that no linear regression is performed; instead, ratios are calculated. This article investigates the potential errors deriving from the use of amounts of spike dissimilar from the sample content, leading to too high (close to 1) or too low (close to 0) slopes/ratios, setting the best conditions in terms of precision and accuracy for the intended determination in the range of approx. 0.5 to 0.6. Also, situations where the use of MER could be recommended over MEC are identified: namely when only a few transitions of sufficient sensitivity and free from overlaps are available or else, many transitions but of similar sensitivity, which may occur when HR CS GFMAS is deployed. Otherwise, for multiple transitions covering a wider sensitivity range, use of linear regression and thus, of MEC, seems favoured, as a better precision can be achieved. The calculation of limits of detection and quantification for both approaches is also discussed. It is finally further demonstrated that these multi-signal strategies help in solving chemical interferences, which very often hamper the determination of non-metals with HR CS GFMAS, and they do so in a simple way, without the need for laborious work or for the preparation of several standards and sample aliquots, therefore making them a very intriguing option when this technique is deployed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Living in a transient world: ICP-MS reinvented via time-resolved analysis for monitoring single events

  • Resano, M.
  • Aramendia, M.
  • Garcia-Ruiz, E.
  • Bazo, A.
  • Bolea-Fernandez, E.
  • Vanhaecke, F.
After 40 years of development, inductively coupled plasma-mass spectrometry (ICP-MS) can hardly be considered as a novel technique anymore. ICP-MS has become the reference when it comes to multi-element bulk analysis at (ultra)trace levels, as well as to isotope ratio determination for metal(loid)s. However, over the last decade, this technique has managed to uncover an entirely new application field, providing information in a variety of contexts related to the individual analysis of single entities (e.g., nanoparticles, cells, or micro/nanoplastics), thus addressing new societal challenges. And this profound expansion of its application range becomes even more remarkable when considering that it has been made possible in an a priori simple way: by providing faster data acquisition and developing the corresponding theoretical substrate to relate the time-resolved signals thus obtained with the elemental composition of the target entities. This review presents the underlying concepts behind single event-ICP-MS, which are needed to fully understand its potential, highlighting key areas of application (e.g., single particle-ICP-MS or single cell-ICP-MS) as well as of future development (e.g., micro/nanoplastics).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A novel approach for adapting the standard addition method to single particle-ICP-MS for the accurate determination of NP size and number concentration in complex matrices; 35414390

  • Aramendía, M.
  • García-Mesa, J. C.
  • Alonso, E. V.
  • Garde, R.
  • Bazo, A.
  • Resano, J.
  • Resano, M.
This paper presents a novel approach, based on the standard addition method, for overcoming the matrix effects that often hamper the accurate characterization of nanoparticles (NPs) in complex samples via single particle inductively coupled plasma mass spectrometry (SP-ICP-MS). In this approach, calibration of the particle size is performed by two different methods: (i) by spiking a suspension of NPs standards of known size containing the analyte, or (ii) by spiking the sample with ionic standards; either way, the measured sensitivity is used in combination with the transport efficiency (TE) for sizing the NPs. Moreover, such transport efficiency can be readily obtained from the data obtained via both calibration methods mentioned above, so that the particle number concentration can also be determined. The addition of both ionic and NP standards can be performed on-line, by using a T-piece with two inlet lines of different dimensions. The smaller of the two is used for the standards, thus ensuring a constant and minimal sample dilution. As a result of the spiking of the samples, mixed histograms including the signal of the sample and that of the standards are obtained. However, the use of signal deconvolution approaches permits to extract the information, even in cases of signal populations overlapping. For proofing the concept, characterization of a 50 nm AuNPs suspension prepared in three different media (i.e., deionized water, 5% ethanol, and 2.5% tetramethyl ammonium hydroxide-TMAH) was carried out. Accurate results were obtained in all cases, in spite of the matrix effects detected in some media. Overall, the approach proposed offers flexibility, so it can be adapted to different situations, but it might be specially indicated for samples for which the matrix is not fully known and/or dilution is not possible/recommended. © 2022 The Authors
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

To shift, or not to shift: Adequate selection of an internal standard in mass-shift approaches using tandem ICP-mass spectrometry (ICP-MS/MS)

  • Bolea-Fernandez E.
  • Rua-Ibarz A.
  • Resano M.
  • Vanhaecke F.
The use of an internal standard to correct for potential matrix effects and instrument instability is common practice in ICP-MS. However, with the introduction of a new generation of ICP-MS instrumentation with a tandem mass spectrometry configuration (ICP-MS/MS), the use of chemical resolution in a mass-shift approach has become much more popular, suggesting that the appropriate selection of an internal standard needs revision. In this particular case, it needs to be decided whether the internal standard should also be subjected to a mass-shift or can simply be monitored on-mass ("to shift, or not to shift"). In this work, 17 elements covering a wide range of masses (24-205 amu) and ionization energies (3.89-9.39 eV) were measured via on-mass and/or mass-shift strategies, and the corresponding atomic ions and reaction product ions were monitored during various systematic experiments. For mass-shifting, an NH3/He gas mixture was used to obtain NH3-based reaction product ions (cluster formation). Product ion scanning (PIS) was used for assessing the differences in reactivity between the different analytes and for the identification of the best suited reaction product ions. It was found that the use of chemical resolution can significantly affect the short-term signal stability and that ion signals measured on-mass are not affected in the same way as those measured mass-shifted. Variations affecting the signal intensities of both atomic and reaction product ions can be attributed to the ion-molecule chemistry occurring within the collision/reaction cell and were found to be related with some degree of initial instability in the cell and differences in reactivity. The use of a sufficiently long stabilization time, however, avoids or at least mitigates such differences in the behavior between signals monitored on-mass and after mass-shifting, respectively. Furthermore, the introduction of cell disturbances, such as those generated after quickly switching between different sets of operating conditions in a multi-tune method, revealed significant differences in signal behavior between atomic and reaction product ions, potentially hampering the use of an internal standard monitored on-mass when the analysis is based on an analyte monitored after mass-shifting. However, the use of a reasonable waiting time again greatly mitigates such differences, with the duration of this stabilization time depending on the magnitude of the cell disturbances (e.g., switch between vented and pressurized mode or only between pressurized modes using different gas flow rates). In addition, also the effect of varying different instrument settings (plasma power, torch position, and gas and liquid flow rates) was evaluated, but no remarkable differences were found between signals monitored on-mass and those mass-shifted. Interestingly, a statistical evaluation of the influence of the different settings on the signal intensities of all ions monitored did not reveal the a priori important role of some properties traditionally suggested for adequate selection of analyte/internal standard pairs, such as mass number or ionization energy, as also suggested in other recent studies. © The Royal Society of Chemistry.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Determination of Cu in blood: Via direct analysis of dried blood spots using high-resolution continuum source graphite furnace atomic absorption spectrometry

  • García-Poyo M.C.
  • Pécheyran C.
  • Rello L.
  • García-González E.
  • Alonso Rodríguez S.
  • Venancio Nakadi F.
  • Aramendía M.
  • Resano M.
The performance of state-of-the-art high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) instrumentation and four novel devices to produce dried blood spots of perfectly defined volumes is evaluated with the aim of developing a simple, direct method for the determination of Cu in blood samples. In all cases, it is feasible to obtain accurate quantitative information using any of the four devices tested (Mitra, HemaXis DB10, Capitainer qDBS and HemaPEN) via simple external calibration with aqueous standards. One of the main differences in the performance of such devices is related to the blanks obtained, such that HemaXis DB10 and HemaPEN are preferred when abnormally low Cu levels (500 µg L-1 or lower), associated with some diseases, need to be determined. The results prove that accurate values with RSD values below 10% can be achieved for these devices even for such Cu levels, while for Capitainer qDBS and, to a higher extent, for Mitra, blank variations will ultimately increase the uncertainty. It is important to stress that analysis of four real samples using both venipuncture and all the DBS specimens showed a very good agreement. Thus, the approach proposed could be readily applied, such that patients with disorders requiring Cu control can prepare their own samples and submit them via postal mail to labs for HR CS GFAAS direct and fast analysis. © The Royal Society of Chemistry.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Cu fractionation, isotopic analysis, and data processing via machine learning: new approaches for the diagnosis and follow up of Wilson's disease via ICP-MS

  • García-Poyo, M. Carmen
  • Bérail, Sylvain
  • Ronzani, Anne Laure
  • Rello, Luis
  • García-González, Elena
  • Nakadi, Flávio V.
  • Aramendía, Maite
  • Resano, Javier
  • Resano, Martín
  • Pécheyran, Christophe
Information about Cu fractionation and Cu isotopic composition can be paramount when investigating Wilson's disease (WD). This information can provide a better understanding of the metabolism of Cu. Most importantly, it may provide an easy way to diagnose and to follow the evolution of WD patients. For such purposes, protocols for Cu determination and Cu isotopic analysis via inductively coupled plasma mass spectrometry were investigated in this work, both in bulk serum and in the exchangeable copper (CuEXC) fractions. The CuEXC protocol provided satisfactory recovery values. Also, no significant mass fractionation during the whole analytical procedure (CuEXC production and/or Cu isolation) was detected. Analyses were carried out in controls (healthy persons), newborns, patients with hepatic disorders, and WD patients. While the results for Cu isotopic analysis are relevant (e.g., δ65Cu values were lower for both WD patients under chelating treatment and patients with hepatic problems in comparison with those values obtained for WD patients under Zn treatments, controls, and newborns) to comprehend Cu metabolism and to follow up the disease, the parameter that can help to better discern between WD patients and the rest of the patients tested (non-WD) was found to be the REC (relative exchangeable Cu). In this study, all the WD patients showed a REC higher than 17%, while the rest showed lower values. However, since establishing a universal threshold is complicated, machine learning was investigated to produce a model that can differentiate between WD and non-WD samples with excellent results (100% accuracy, albeit for a limited sample set). Most importantly, unlike other ML approaches, our model can also provide an uncertainty metric to indicate the reliability of the prediction, overall opening new ways to diagnose WD.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Evaluation of electrothermal vaporization for sample introduction aiming at Cu isotopic analysis via multicollector-inductively coupled plasma mass spectrometry

  • Garcia-Poyo, MC
  • Ronzani, AL
  • Frayret, J
  • Berail, S
  • Rello, L
  • Garcia-Gonzalez, E
  • Lelievre, B
  • Nakadi, FV
  • Aramendia, M
  • Resano, M
  • Pecheyran, C
A new method for Cu isotopic analysis was developed using a commercially available electrothermal vaporization (ETV) device coupled to multicollector-inductively coupled plasma mass spectrometry (MC-ICP-MS). The method demonstrated potential for the isotopic analysis of microsamples (e.g., 5 mu L) in a biological context. For example, Cu isotopic analysis of NIST 3114 (diluted to 1 mg L-1 Cu) using self-bracketing provided average delta Cu-65 values of 0.00 +/- 0.17%0 (2SD, n = 10) and internal precision values of 712 ppm. In order to achieve this level of accuracy and precision, it is critical to properly deal with the short transient signals generated by the ETV-MC-ICP-MS, which implies using point by point calculations and time lag detector correction (TDC), as well as a criterion to reject potential outliers. The results of this technique were compared with the results obtained via femtosecond-laser ablation-MC-ICPMS using the same pre-treated serum samples. No significant differences were observed among the results obtained in both cases, while external precision was 0.26%0 for ETV-MC-ICP-MS and 0.24%0 for fs-LA-MC-ICP-MS, expressed as median value of 2SD (n = 27), further proving the usefulness of the approach proposed in this context, as the use of ETV results in a more straightforward approach.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

An insight into the determination of size and number concentration of silver nanoparticles in blood using single particle ICP-MS (spICP-MS): Feasibility of application to samples relevant to: In vivo toxicology studies

  • Abad-Alvaro I.
  • Leite D.
  • Bartczak D.
  • Cuello-Nunez S.
  • Gomez-Gomez B.
  • Madrid Y.
  • Aramendia M.
  • Resano M.
  • Goenaga-Infante H.
Toxicological studies concerning nanomaterials in complex biological matrices usually require a carefully designed workflow that involves handling, transportation and preparation of a large number of samples without affecting the nanoparticle (NP) characteristics, as well as measurement methods that enable their reliable characterisation. This work describes method development for the determination of number concentration and size of silver nanoparticles (AgNP) in blood for the purpose of application to the typical workflow of an in vivo toxicology assessment involving blood-containing AgNP and Ag(i) leached out from medical devices. A systematic comparison of single particle detection using millisecond versus microsecond dwell times in the presence of different ionic Ag [Ag(i)]-to-AgNP ratios by spICP-MS was undertaken to achieve sufficient selectivity for the determination of NP number concentration. This was achieved for the first time in a complex media such as 2.5% tetramethylammonium hydroxide (TMAH)/0.1% Triton X-100 (v/v) diluent, which was proven to preserve nanoparticle stability upon 8 days of storage following AgNP quantitative extraction from the blood matrix. The potential of microsecond dwell time for improved discrimination of AgNP (40 nm) from Ag(i) was demonstrated for ionic to nanoparticle ratios [Ag(i)/AgNP] of up to 106-fold. For NP sizing, a systematic study of the impact of matrix-matched ionic calibration on the derived particle size by spICP-MS is also described. Three different ionic calibration media including 1% HNO3 (v/v), 1 mM trisodium citrate and 2.5% TMAH/0.1% Triton X-100 (v/v) were tested. Student t-test evidenced statistically significant differences between the slope of the calibration curve of Ag(i) in TMAH/Triton X-100 compared to HNO3 and trisodium citrate matrices, whereas no significant differences were found between the two latter media. Moreover, a good agreement was found between the particle diameter derived from spICP-MS following ionic calibration in TMAH/Triton X-100 and the diameter obtained with transmission electron microscopy (TEM), demonstrating the importance of matrix-matched calibration for NP size determination in a complex matrix using spICP-MS. Number concentration recovery measurements on blood samples spiked with AgNP and size measurements both using spICP-MS demonstrated the feasibility of the methodology developed here for potential future application to AgNP characterisation in toxicology research. © The Royal Society of Chemistry.