Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Living in a transient world: ICP-MS reinvented via time-resolved analysis for monitoring single events

  • Resano, M.
  • Aramendia, M.
  • Garcia-Ruiz, E.
  • Bazo, A.
  • Bolea-Fernandez, E.
  • Vanhaecke, F.
After 40 years of development, inductively coupled plasma-mass spectrometry (ICP-MS) can hardly be considered as a novel technique anymore. ICP-MS has become the reference when it comes to multi-element bulk analysis at (ultra)trace levels, as well as to isotope ratio determination for metal(loid)s. However, over the last decade, this technique has managed to uncover an entirely new application field, providing information in a variety of contexts related to the individual analysis of single entities (e.g., nanoparticles, cells, or micro/nanoplastics), thus addressing new societal challenges. And this profound expansion of its application range becomes even more remarkable when considering that it has been made possible in an a priori simple way: by providing faster data acquisition and developing the corresponding theoretical substrate to relate the time-resolved signals thus obtained with the elemental composition of the target entities. This review presents the underlying concepts behind single event-ICP-MS, which are needed to fully understand its potential, highlighting key areas of application (e.g., single particle-ICP-MS or single cell-ICP-MS) as well as of future development (e.g., micro/nanoplastics).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A novel approach for adapting the standard addition method to single particle-ICP-MS for the accurate determination of NP size and number concentration in complex matrices; 35414390

  • Aramendía, M.
  • García-Mesa, J. C.
  • Alonso, E. V.
  • Garde, R.
  • Bazo, A.
  • Resano, J.
  • Resano, M.
This paper presents a novel approach, based on the standard addition method, for overcoming the matrix effects that often hamper the accurate characterization of nanoparticles (NPs) in complex samples via single particle inductively coupled plasma mass spectrometry (SP-ICP-MS). In this approach, calibration of the particle size is performed by two different methods: (i) by spiking a suspension of NPs standards of known size containing the analyte, or (ii) by spiking the sample with ionic standards; either way, the measured sensitivity is used in combination with the transport efficiency (TE) for sizing the NPs. Moreover, such transport efficiency can be readily obtained from the data obtained via both calibration methods mentioned above, so that the particle number concentration can also be determined. The addition of both ionic and NP standards can be performed on-line, by using a T-piece with two inlet lines of different dimensions. The smaller of the two is used for the standards, thus ensuring a constant and minimal sample dilution. As a result of the spiking of the samples, mixed histograms including the signal of the sample and that of the standards are obtained. However, the use of signal deconvolution approaches permits to extract the information, even in cases of signal populations overlapping. For proofing the concept, characterization of a 50 nm AuNPs suspension prepared in three different media (i.e., deionized water, 5% ethanol, and 2.5% tetramethyl ammonium hydroxide-TMAH) was carried out. Accurate results were obtained in all cases, in spite of the matrix effects detected in some media. Overall, the approach proposed offers flexibility, so it can be adapted to different situations, but it might be specially indicated for samples for which the matrix is not fully known and/or dilution is not possible/recommended. © 2022 The Authors
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Cu fractionation, isotopic analysis, and data processing via machine learning: new approaches for the diagnosis and follow up of Wilson's disease via ICP-MS

  • García-Poyo, M. Carmen
  • Bérail, Sylvain
  • Ronzani, Anne Laure
  • Rello, Luis
  • García-González, Elena
  • Nakadi, Flávio V.
  • Aramendía, Maite
  • Resano, Javier
  • Resano, Martín
  • Pécheyran, Christophe
Information about Cu fractionation and Cu isotopic composition can be paramount when investigating Wilson's disease (WD). This information can provide a better understanding of the metabolism of Cu. Most importantly, it may provide an easy way to diagnose and to follow the evolution of WD patients. For such purposes, protocols for Cu determination and Cu isotopic analysis via inductively coupled plasma mass spectrometry were investigated in this work, both in bulk serum and in the exchangeable copper (CuEXC) fractions. The CuEXC protocol provided satisfactory recovery values. Also, no significant mass fractionation during the whole analytical procedure (CuEXC production and/or Cu isolation) was detected. Analyses were carried out in controls (healthy persons), newborns, patients with hepatic disorders, and WD patients. While the results for Cu isotopic analysis are relevant (e.g., δ65Cu values were lower for both WD patients under chelating treatment and patients with hepatic problems in comparison with those values obtained for WD patients under Zn treatments, controls, and newborns) to comprehend Cu metabolism and to follow up the disease, the parameter that can help to better discern between WD patients and the rest of the patients tested (non-WD) was found to be the REC (relative exchangeable Cu). In this study, all the WD patients showed a REC higher than 17%, while the rest showed lower values. However, since establishing a universal threshold is complicated, machine learning was investigated to produce a model that can differentiate between WD and non-WD samples with excellent results (100% accuracy, albeit for a limited sample set). Most importantly, unlike other ML approaches, our model can also provide an uncertainty metric to indicate the reliability of the prediction, overall opening new ways to diagnose WD.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

An approach based on an increased bandpass for enabling the use of internal standards in single particle ICP-MS: application to AuNPs Characterization

  • Bazo, Antonio
  • Aramendía, Maite
  • Nakadi, Flávio V.
  • Resano, Martín
This paper proposes a novel approach to implement an internal standard (IS) correction in single particle inductively coupled plasma mass spectrometry (SP ICP-MS), as exemplified for the characterization of Au nanoparticles (NPs) in complex matrices. This approach is based on the use of the mass spectrometer (quadrupole) in bandpass mode, enhancing the sensitivity for the monitoring of AuNPs while also allowing for the detection of PtNPs in the same measurement run, such that they can serve as an internal standard. The performance of the method developed was proved for three different matrices: pure water, a 5 g L−1 NaCl water solution, and another water solution containing 2.5% (m/v) tetramethylammonium hydroxide (TMAH)/0.1% Triton X-100. It was observed that matrix-effects impacted both the sensitivity of the NPs and their transport efficiencies. To circumvent this problem, two methods were used to determine the TE: the particle size method for sizing and the dynamic mass flow method for the determination of the particle number concentration (PNC). This fact, together with the use of the IS, enabled us to attain accurate results in all cases, both for sizing and for the PNC determination. Additionally, the use of the bandpass mode provides additional flexibility for this characterization, as it is possible to easily tune the sensitivity achieved for each NP type to ensure that their distributions are sufficiently resolved.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Isotope dilution analysis for particle mass determination using single-particle inductively coupled plasma time-of-flight mass spectrometry: application to size determination of silver nanoparticles

  • Aramendía, Maite
  • Leite, Diego
  • Resano, Javier
  • Resano, Martín
  • Billimoria, Kharmen
  • Goenaga-Infante, Heidi
This paper describes methodology based on the application of isotope dilution (ID) in single-particle inductively coupled plasma time-of-flight mass spectrometry (spICP-ToFMS) mode for the mass determination (and sizing) of silver nanoparticles (AgNPs). For this purpose, and considering that the analytical signal in spICP-MS shows a transient nature, an isotope dilution equation used for online work was adapted and used for the mass determination of individual NPs. The method proposed measures NP isotope ratios in a particle-to-particle approach, which allows for the characterization of NP mass (and size) distributions and not only the mean size of the distribution. For the best results to be obtained, our method development (undertaken through the analysis of the reference material NIST RM 8017) included the optimization of the working conditions for the best precision and accuracy in isotope ratios of individual NPs, which had been only reported to date with multicollector instruments. It is shown that the precision of the measurement of these ratios is limited by the magnitude of the signals obtained for each NP in the mass analyzer (counting statistics). However, the uncertainty obtained for the sizing of NPs in this approach can be improved by careful method optimization, where the most important parameters are shown to be the selection of the spike isotopic composition and concentration. Although only AgNPs were targeted in this study, the method presented, with the corresponding adaptations, could be applied to NPs of any other composition that include an element with different naturally available isotopes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

High-resolution continuum source graphite furnace molecular absorption spectrometry for the monitoring of Sr isotopes via SrF formation: a case study

  • Bazo, Antonio
  • Garde, Raúl
  • Garcia-Ruiz, Esperanza
  • Aramendía, Maite
  • Nakadi, Flávio V.
  • Resano, Martín
High-resolution continuum source graphite furnace molecular absorption spectrometry (HR CS GFMAS) can provide isotopic information under certain conditions, thus broadening its field of application. However, to date, only elements with two major stable isotopes have been monitored via this technique. In this work, the possibilities of HR CS GFMAS to determine isotope ratios of elements with more than two stable isotopes are evaluated for the first time. For this purpose, Sr was chosen as the analyte and SrF as the target species, so four different signals corresponding to four stable Sr isotopes (88Sr, 87Sr, 86Sr and 84Sr) should be distinguished. Nevertheless, due to the number of strontium isotopes, the shape of the peaks, and the resolution that the instrument exhibits in the spectral window, isotopic signals overlap, thus leading to potentially biased results. To circumvent this issue, a deconvolution protocol, consisting of measuring and correcting for the contribution of each isotope on the signals of the rest, was developed. These contributions were calculated as the signal ratio between the absorbance of the monoisotopic profile at the wavelengths where the maxima of other isotopes are expected and at its own maximum. Therefore, the interference can be simply subtracted from the net signal registered for the interfered isotope. The performance of this method was demonstrated for both naturally abundant and isotope-enriched Sr standards, paving the way for future applications in this field. Analysis of a real sample (tap water) spiked with a 84Sr solution is also demonstrated.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Serum Mg isotopic composition reveals that Mg dyshomeostasis remains in type 1 diabetes despite the resolution of hypomagnesemia

  • Sullivan, Kaj Vaughan
  • Assantuh, Yasmina
  • Grigoryan, Rosa
  • Costas-Rodríguez, Marta
  • Bolea-Fernandez, Eduardo
  • Lapauw, Bruno
  • Van Laecke, Steven
  • Vanhaecke, Frank
Hypomagnesemia was historically prevalent in individuals with type 1 diabetes mellitus (T1DM), but contemporary results indicate an incidence comparable to that in the general population, likely due to improved treatment in recent decades, resulting in better glycemic control. However, a recent study found a significant difference between the serum Mg isotopic composition of T1DM individuals and controls, indicating that disruptions to Mg homeostasis persist. Significant deviations were also found in samples taken one year apart. To investigate whether the temporal variability in serum Mg isotopic composition is linked to the transient impact of administered insulin, Mg isotope ratios were determined in serum from 15 T1DM individuals before and one hour after insulin injection/meal consumption using multi-collector inductively coupled plasma-mass spectrometry. Consistent with results of the previous study, significant difference in the serum Mg isotopic composition was found between T1DM individuals and 10 sex-matched controls. However, the average difference between pre- and post-insulin injection/meal T1DM samples of 0.05 ± 0.13‰ (1SD) was not significant. No difference was observed for controls before (−0.12 ± 0.16‰) and after the meal (−0.10 ± 0.13‰) either, suggesting a lack of a postprandial Mg isotopic response within one hour of food consumption, and that the timing of the most recent meal may not require controlling for when determining serum Mg isotopic composition.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Evaluation of electrothermal vaporization for sample introduction aiming at Cu isotopic analysis via multicollector-inductively coupled plasma mass spectrometry

  • Garcia-Poyo, MC
  • Ronzani, AL
  • Frayret, J
  • Berail, S
  • Rello, L
  • Garcia-Gonzalez, E
  • Lelievre, B
  • Nakadi, FV
  • Aramendia, M
  • Resano, M
  • Pecheyran, C
A new method for Cu isotopic analysis was developed using a commercially available electrothermal vaporization (ETV) device coupled to multicollector-inductively coupled plasma mass spectrometry (MC-ICP-MS). The method demonstrated potential for the isotopic analysis of microsamples (e.g., 5 mu L) in a biological context. For example, Cu isotopic analysis of NIST 3114 (diluted to 1 mg L-1 Cu) using self-bracketing provided average delta Cu-65 values of 0.00 +/- 0.17%0 (2SD, n = 10) and internal precision values of 712 ppm. In order to achieve this level of accuracy and precision, it is critical to properly deal with the short transient signals generated by the ETV-MC-ICP-MS, which implies using point by point calculations and time lag detector correction (TDC), as well as a criterion to reject potential outliers. The results of this technique were compared with the results obtained via femtosecond-laser ablation-MC-ICPMS using the same pre-treated serum samples. No significant differences were observed among the results obtained in both cases, while external precision was 0.26%0 for ETV-MC-ICP-MS and 0.24%0 for fs-LA-MC-ICP-MS, expressed as median value of 2SD (n = 27), further proving the usefulness of the approach proposed in this context, as the use of ETV results in a more straightforward approach.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A comparison of calibration strategies for quantitative laser ablation ICP-mass spectrometry (LA-ICP-MS) analysis of fused catalyst samples

  • Rua-Ibarz, Ana
  • Van Acker, Thibaut
  • Bolea-Fernández, Eduardo
  • Boccongelli, Marina
  • Vanhaecke, Frank
In the field of petrochemistry, the quantitative determination of trace elements in catalysts is crucial for optimizing various types of processes. Catalyst poisoning, resulting from the presence of contaminants, can lead to decreased performance and efficiency, even when these are present at trace level only. Inductively coupled plasma-mass spectrometry (ICP-MS) is a powerful technique for trace elemental analysis, but its application to catalysts is challenging due to their physicochemical characteristics challenging straightforward dissolution. Laser ablation (LA) coupled to ICP-MS (LA-ICP-MS) has emerged as a valuable approach for direct analysis of solid samples. However, developing an appropriate calibration strategy for reliable quantitative LA-ICP-MS analysis of catalyst samples remains a challenge. In this work, different calibration strategies for quantitative LA-ICP-MS analysis of fused catalyst samples were evaluated. The traditional strategy relied on external calibration against certified reference materials (CRMs) combined with internal standardization and was considered the reference approach. When using this approach, the relative bias with respect to the reference value was found to be <15%. Two novel calibration strategies were introduced and compared: a so-called multi-signal calibration approach and a solution-based calibration approach. The multi-signal calibration strategy involved varying the laser repetition rate (20, 30, 40 and 50 Hz) or laser beam diameter (10, 12, 15 and 20 μm), allowing a calibration curve to be constructed by comparing the analytical signal intensity for a single solid CRM with that for the sample, thus partially overcoming the shortage of CRMs for quantitative LA-ICP-MS analysis. The solution-based calibration approach was used for quantitative multi-element analysis without the need for any solid standard and required only minor hardware modifications to accommodate the introduction of aqueous standard solutions for calibration. Various glass certified reference materials were used for method development, calibration, and validation purposes. Furthermore, two fused alumina catalyst samples (used in the context of petroleum refining processes) were successfully analyzed as a proof-of-concept application. For both the multi-signal (matrix-matched conditions) and the solution-based calibration approaches, the average relative bias between the experimentally determined and certified/reference concentrations varied between −9% and +7%.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Extending the application range of Hg isotopic analysis to sub-µg L-1 levels using cold vapor generation multi-collector inductively coupled plasma-mass spectrometry with 1013 ohm Faraday cup amplifiers

  • Suárez-Criado, Laura
  • Bolea-Fernández, Eduardo
  • Abou-Zeid, Lana
  • Vandermeiren, Mathias
  • Rodríguez-González, Pablo
  • Garcia Alonso, Jose Ignacio
  • Vanhaecke, Frank
High-precision determination of the isotopic composition of mercury (Hg) is of paramount importance for unraveling its biogeochemical cycle and for identifying the origin of Hg in environmental compartments. Cold vapor generation multi-collector inductively coupled plasma-mass spectrometry (CVG-MC-ICP-MS) is the standard approach for such application. Cold vapor generation provides a high Hg introduction efficiency into the ICP, while chromatographic Hg isolation is not required as a result of the selective reaction between Hg2+ and SnCl2. For environmental or biota samples with low Hg concentrations, however, this approach still presents challenges and reliable measurements typically require a Hg concentration ≥1 μg L−1 in the solution analyzed. Recent improvements of MC-ICP-MS instrumentation, including the introduction of the so-called Jet interface and 1013 Ω Faraday cup amplifiers, enhance the signal-to-noise ratio. In this study, it was investigated to what extent this allows Hg isotopic analysis at lower concentration. Performance in Hg isotopic analysis was compared using two different sets of cones (standard vs. Jet), two plasma conditions (wet vs. dry) and two amplifier types (1011 Ω vs. 1013 Ω). Satisfactory accuracy and precision were achieved at a Hg concentration down to 0.1 μg L−1 in the solution measured when using Jet cones, dry plasma conditions, and the four available 1013 Ω amplifiers. The uncertainty expressed as 2SD for the δ202Hg values measured for the in-house standard solution was ±0.2‰ at 0.25 μg Hg L−1 and ± 0.3‰ at 0.1 μg Hg L−1. The method was subsequently applied to the analysis of real surface water samples contaminated with toxic metals.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Tracing isotopically labeled selenium nanoparticles in plants via single-particle ICP-mass spectrometry

  • Moreira Freire, Bruna
  • Rua-Ibarz, Ana
  • Venâncio Nakadi, Flávio
  • Bolea-Fernández, Eduardo
  • Barriuso-Vargas, Juan J.
  • Lange, Camila Neves
  • Aramendía, Maite
  • Batista, Bruno Lemos
  • Resano, Martín
Agronomic biofortification using selenium nanoparticles (SeNPs) shows potential for addressing selenium deficiency but further research on SeNPs-plants interaction is required before it can be effectively used to improve nutritional quality. In this work, single-particle inductively coupled plasma-mass spectrometry (SP-ICP-MS) was used for tracing isotopically labeled SeNPs (82SeNPs) in Oryza sativa L. tissues. For this purpose, SeNPs with natural isotopic abundance and 82SeNPs were synthesized by a chemical method. The NPs characterization by transmission electron microscopy (TEM) confirmed that enriched NPs maintained the basic properties of unlabeled NPs, showing spherical shape, monodispersity, and sizes in the nano-range (82.8 ± 6.6 nm and 73.2 ± 4.4 nm for SeNPs and 82SeNPs, respectively). The use of 82SeNPs resulted in an 11-fold enhancement in the detection power for ICP-MS analysis, accompanied by an improvement in the signal-to-background ratio and a reduction of the size limits of detection from 89.9 to 39.9 nm in SP-ICP-MS analysis. This enabled 82SeNPs to be tracked in O. sativa L. plants cultivated under foliar application of 82SeNPs. Tracing studies combining SP-ICP-MS and TEM-energy-dispersive X-ray spectroscopy data confirmed the uptake of intact 82SeNPs by rice leaves, with most NPs remaining in the leaves and very few particles translocated to shoots and roots. Translocation of Se from leaves to roots and shoots was found to be lower when applied as NPs compared to selenite application. From the size distributions, as obtained by SP-ICP-MS, it can be concluded that a fraction of the 82SeNPs remained within the same size range as that of the applied NP suspension, while other fraction underwent an agglomeration process in the leaves, as confirmed by TEM images. This illustrates the potential of SP-ICP-MS analysis of isotopically enriched 82SeNPs for tracing NPs in the presence of background elements within complex plant matrices, providing important information about the uptake, accumulation, and biotransformation of SeNPs in rice plants.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Development and initial evaluation of a combustion-based sample introduction system for direct isotopic analysis of mercury in solid samples via multi-collector ICP-mass spectrometry

  • Bolea-Fernández, Eduardo
  • Rua-Ibarz, Ana
  • Anjos, Jorge Alves
  • Vanhaecke, Frank
High-precision isotopic analysis of mercury (Hg) using multi-collector ICP-mass spectrometry (MC-ICP-MS) is a powerful method for obtaining insight into the sources, pathways and sinks of this toxic metal. Modification of a commercially available mercury analyzer (Teledyne Leeman Labs, Hydra IIc – originally designed for quantification of Hg through sample combustion, collection of the Hg vapor on a gold amalgamator, subsequent controlled release of Hg and detection using cold vapor atomic absorption spectrometry CVAAS) enabled the system to be used for the direct high-precision Hg isotopic analysis of solid samples using MC-ICP-MS – i.e., without previous sample digestion and subsequent dilution. The changes made to the mercury analyzer did not compromise its (simultaneous) use for Hg quantification via CVAAS. The Hg vapor was mixed with a Tl-containing aerosol produced via pneumatic nebulization, creating wet plasma conditions, and enabling the use of Tl as an internal standard for correction of instrumental mass discrimination. Accurate and precise (0.10 ‰ 2SD, δ202Hg, n = 5) results were obtained for an in-house standard solution of Hg (20 ng Hg sample intake). Initial validation relied on the successful analysis of two solid certified reference materials of biological origin (BCR CRM 464 Tuna fish and NRC-CNRC TORT-3 Lobster hepatopancreas). It was shown that instrumental mass discrimination can be adequately corrected for by relying on the use of an aqueous Hg standard solution (NIST SRM 3133), without the need of matrix-matching. The novel setup developed thus allows for direct high-precision isotopic analysis of Hg in solid samples, thus enhancing the sample throughput. It is also suited for samples for which low amounts are available only and/or that are characterized by low Hg concentrations.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Intensity- and time-based strategies for micro/nano-sizing via single-particle ICP-mass spectrometry: A comparative assessment using Au and SiO2 as model particles

  • Bazo, Antonio
  • Bolea-Fernandez, Eduardo
  • Rua-Ibarz, Ana
  • Aramendía, Maite
  • Resano, Martín
Background Single-particle ICP-mass spectrometry (SP-ICP-MS) is a powerful method for micro/nano-particle (MNP) sizing. Despite the outstanding evolution of the technique in the last decade, most studies still rely on traditional approaches based on (1) the use of integrated intensity as the analytical signal and (2) the calculation of the transport efficiency (TE). However, the increasing availability of MNP standards and advancements in hardware and software have unveiled new venues for MNP sizing, including TE-independent and time-based approaches. This work systematically examines these different methodologies to identify and summarize their strengths and weaknesses, thus helping to determine their preferred application areas. Results Different SP-ICP-MS methods for MNP sizing were assessed using AuNPs (20–70 nm) and SiO2MNPs (100–1000 nm). Among TE-dependent approaches, the particle frequency method was characterized by larger uncertainties than the particle size method. The results of the latter were dependent on the appropriate selection of the reference MNP, making the use of multiple reference MNPs recommended. TE-independent methods were based on external (linear and polynomial) calibrations and a relative approach. These methods exhibited the lowest uncertainties of all the strategies evaluated. External calibrations benefited from simpler calculations, but their application could be hindered by a lack of reference MNPs within the desired size range or by the need for interpolations outside the calibration range. Finally, transit time signals are directly proportional to the MNP size rather than its mass. The time-based method demonstrated adequate performance for sizing AuNPs but failed when sizing the largest SiO2MNPs (1000 nm). Significance and novelty This work provides further insights into the application of different SP-ICP-MS methodologies for MNP sizing. Both TE-independent approaches and the monitoring of the transit time as the analytical signal are underused strategies; in this context, a Python script was developed for accurate transit time measurement. After 20 years of development, a quantitative comparison of the different methodologies, including the most novel approaches, is deemed necessary for further growth on solid theoretical ground.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Cinnabar for Roman Ephesus: Material quality, processing and provenance

  • Rodler-Rørbo, Alexandra
  • Baragona, Anthony J.
  • Verbeemen, Eliah J.
  • Sørensen, Lasse Vilien
  • Çakmakoglu, Berk
  • Helvaci, Cahit
  • Bolea-Fernandez, Eduardo
  • Rua-Ibarz, Ana
  • Vanhaecke, Frank
  • Becker, Hilary
  • Artioli, Gilberto
  • Zabrana, Lilli
  • Debaille, Vinciane
  • Mattielli, Nadine
  • Goderis, Steven
  • Claeys, Philippe
Ephesus was an important harbor city that flourished during the Roman period and ancient texts mention Almadén in Spain and the Cilbian fields of Ephesus as important cinnabar sources in antiquity. This work investigates whether imported cinnabar was used and whether this could be related to changes in painting activities over time. Microscopic analysis indicates a consistent preparation of cinnabar, hinting at a uniform source material quality or processing technique. However, the use of cinnabar varies among the architectural structures studied, indicating a plurality of painting techniques. A few of the analyzed cinnabar samples overlap with Turkish- and Balkan reference Pb isotope ratios; three samples from tabernas, however, deviate from this. The Hg isotope ratios reveal that cinnabar from carbonate-hosted deposits was likely used, and that processing of cinnabar included heating as suggested by ancient texts. Most notably, a correlation exists between the geochemical data and the painting technique – shifts in sourcing and cinnabar usage are potentially assignable to building chronology and/or usage. Through the lens of material provenance and processing, Ephesian cinnabar brings the organization of pigment trade into focus.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

High-precision Cu isotopic analysis of human dietary Cu sources via multi-collector ICP-mass spectrometry

  • Sullivan, Kaj V.
  • Moser, Katharina
  • Costas-Rodríguez, Marta
  • Bolea-Fernandez, Eduardo
  • Vanhaecke, Frank
The disruption of Cu homeostasis is associated with the pathogenesis of many diseases and can result in alterations in Cu isotope fractionation. Changes in the Cu isotope ratio (65Cu/63Cu) of body fluids and tissues have been observed in liver disorders, cancers, and other diseases, displaying diagnostic/prognostic potential. However, it is not entirely clear whether certain physiological or lifestyle factors may also influence the bodily Cu isotopic composition, potentially obfuscating the signature of the pathology. To ascertain whether differences exist between food products, the Cu isotopic composition of 29 significant dietary Cu sources has been determined for the first time. The general enrichment of Cu and its heavy isotope, 65Cu, in legumes, nuts, and seeds (major Cu sources in plant-based diets) was revealed, suggesting that individuals with plant-based diets may have a bodily Cu isotopic composition offset from that of individuals with omnivorous diets, thus requiring controlling for in study design.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

LAMIS in the gas phase: A new approach for obtaining Ca elemental and isotopic information via CaF molecule formation

  • Venancio Nakadi, Flávio.
  • Garcia-Garcia, Alicia
  • Rua-Ibarz, Ana
  • Resano, Martín
This work introduces a novel method for generating the calcium monofluoride (CaF) diatomic molecule by adding the molecule-forming reagent in the gaseous phase (a methyl fluoride-argon mixture), in order to perform laser-induced breakdown spectroscopy (LIBS) and laser ablation molecular isotopic spectrometry (LAMIS) measurements. By optimizing the instrumental parameters, CaF molecule formation was successfully achieved within the plasma plume, upon ablation of dried liquid samples. The isotopic shift for the X2Σ→A2Π (0,1) CaF vibronic transition at 583.0 nm was calculated to be 292.3 pm. The method proved capable of providing quantitative information for determining calcium concentrations in real samples, such as tap water and skimmed milk, using internal standardization (with Sr as internal standard; limit of detection, LOD, 20 mg L−1) and isotope dilution (which can be applied from 400 mg L−1on), respectively. Partial least squares regression (PLS) analysis was employed to enhance the quality of the isotopic data. The Ca concentration found in the tap water was 47 ± 16 mg L−1 (reference flame atomic absorption spectrometry, FAAS, value: 59 ± 0.2 mg L−1), and 1100 ± 140 mg L−1 for the skimmed milk (reference FAAS value: 1240 ± 120 mg L−1). No significant difference between LIBS and FAAS results could be established using a t-test at the 95% confidence level. Overall, this novel approach allows for the determination of calcium in terms of both the elemental concentration and the isotopic composition, thus broadening the applicability of LIBS (e.g., for tracer experiments, besides the already mentioned application of isotope dilution).
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Ions with Ions, Entities with Entities: A Proof-of-Concept Study Using the SELM-1 Yeast Certified Reference Material for Intra- and Extracellular Se Quantification via Single-Cell ICP-Mass Spectrometry

  • Bazo, Antonio
  • Bolea-Fernandez, Eduardo
  • Rua-Ibarz, Ana
  • Aramendía, Maite
  • Resano, Martín
In this work, two novel nanoparticle (NP)-based calibration strategies, external calibration and a relative method, have been explored for single-cell ICP-mass spectrometry (SC-ICP-MS) analysis. The fundamental principle of these methods is to rely on individual entities (well-characterized NPs of the target analyte) for calibration rather than on ionic standard solutions. The performance of the NP-based calibration approaches has been compared to that of the reference method (particle size with AuNP standards). In addition to the intracellular Se content (mass per individual cell), the extracellular Se (dissolved fraction) was also determined directly and simultaneously using the average background from the SC-ICP-MS time-resolved signal. The figures-of-merit of the methods developed have been evaluated by relying on the analysis of the SELM-1 cell-certified reference material, consisting of Se-enriched yeast cells, and certified for its total Se content (intracellular + extracellular Se). All methods successfully determined the Se elemental contents, but an improvement in accuracy and precision was observed for the NP-based methods compared to the reference one. Furthermore, the NP-based methods were found to be less time-consuming, more straightforward, and more user-friendly in terms of calculations. These results open new avenues for calibration in quantitative SC-ICP-MS analysis and call for a fundamental change in the methodology, where the determination of ionic contents is based on the use of ionic standard solutions for calibration, while the determination of elemental contents in discrete micro/nanoentities, such as cells, should ideally be based on calibration using standard entities, thus avoiding the need to calculate a transport efficiency coefficient.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A novel particle mass calibration strategy for the quantification of AuNPs in single cancer cells <i>via</i> laser ablation ICP-mass spectrometry. A case study

  • Bazo, Antonio
  • Bolea-Fernandez, Eduardo
  • Billimoria, Kharmen
  • Rua-Ibarz, Ana
  • Aramendía, Maite
  • Menero-Valdés, Paula
  • Morley, Jack
  • Neves, Sara
  • Sánchez-Cachero, Armando
  • Goenaga-Infante, Heidi
  • Resano, Martín
Laser ablation ICP-mass spectrometry (LA-ICP-MS) has developed as a powerful tool for elemental quantitative analysis of individual cells, assuring that the content of each cell is analyzed individually. However, this technique is still limited by the difficulties associated with calibration using solid standards. This work proposes a particle mass calibration strategy that is independent of both the properties and thickness of the gelatin films used for calibration, overcoming a significant drawback of previously established methods. The fundamental principle of this strategy relies on the individual ablation of nanoparticles (NPs) of well-characterized size that are embedded in the films, so that their mass can be directly used for calibration without the need to calculate their exact concentration within the gelatin. The performance of the newly developed method was compared to that of the previously reported approaches (ionic and particle number calibration) in terms of linearity and homogeneity between different films prepared from the same gelatin solution. As a case study, the three calibration strategies were used for the quantitative analysis of HeLa cancer cells exposed to AuNPs. In parallel, in-suspension single-cell (SC) ICP-MS Au data were obtained and used as reference for comparison with the three LA-SC-ICP-MS strategies. The results obtained with the novel particle mass approach demonstrated better accuracy and repeatability over three different working sessions, addressing key limitations and providing a robust and reliable method for quantitative LA-SC-ICP-MS analysis. The particle mass method holds promise for quantitative LA-ICP-MS analysis of samples beyond NP-exposed cells, such as biological tissues.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Laser Ablation for Nondestructive Sampling of Microplastics in Single-Particle ICP-Mass Spectrometry

  • Van Acker, Thibaut
  • Rua-Ibarz, Ana
  • Vanhaecke, Frank
  • Bolea-Fernandez, Eduardo
In this work, laser ablation (LA) was characterized as a method for sampling and introducing microplastic particles (MPs) into an inductively coupled plasma (ICP) for subsequent 13C+ monitoring using an ICP-mass spectrometer operated in single-event mode. MPs of different types (PS, PMMA, and PVC) and sizes (2–20 µm) were introduced intactly. The laser energy density did not affect the particle sampling across a wide range (0.25–6.00 J cm–2). Single-shot analysis separated clustered MPs (2–7 MPs per cluster) during the LA and particle transport processes, allowing the temporally resolved analysis of the individual constituting MPs. Line scanning showed superior performance when using a small laser beam diameter combined with a high repetition rate. The 13C+ signal intensity correlated linearly (R2 >0.9945) with the absolute C mass in a 2–10 µm size range, while the use of He in the collision-reaction cell (CRC) allowed extension of the linear range to 20 µm. The LA approach generated narrower 13C+ signal distributions than the traditional solution-based approach (dry versus wet plasma conditions) and proved successful for the analysis of a mixed suspension (containing four sizes of PS MPs in a 2–5 µm size range) and for sampling MPs from PVDF and glass microfiber filters, with the latter offering a lower background.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Improving detection and figures of merit in single-particle inductively coupled plasma-mass spectrometry via transient event heights

  • Bazo, Antonio
  • López-Villellas, Lorién
  • Mataloni, Matilde
  • Bolea-Fernandez, Eduardo
  • Rua-Ibarz, Ana
  • Grotti, Marco
  • Aramendía, Maite
  • Resano, Martín
Background: Single-particle inductively coupled plasma-mass spectrometry (SP-ICP-MS) is a powerful method for characterizing micro- and nanoparticulate materials. The technique primarily relies on the linear relationship between the integrated intensities of individual events (peak areas) and the analyte mass, though transit times (peak widths) have also been used for quantitative purposes. This work (1) evaluates the potential of using peak heights as analytical signals in SP-ICP-MS, (2) introduces a new method for determining peak heights, and (3) explores scenarios in which peak height offers added value over the commonly used SP-ICP-MS signals. Results: A new method was proposed to estimate peak height values in SP-ICP-MS accurately. The cumulative intensity across consecutive dwell times was modeled using a third-degree polynomial, from which the adjusted peak height was derived. This approach reduces the uncertainty associated with using raw maximum intensity values, yielding NP distributions comparable to those obtained via integrated intensities. The effect of dwell time on peak height was also evaluated. An optimal range (50 μs–200 μs) was identified, where a linear relationship was observed between the peak height and the square of the NP diameter. Within this range, peak height showed the lowest bias when characterizing smaller NPs, indicating the potential to improve the limit of quantification (LoQ). Additionally, peak heights proved helpful in determining the limit of detection (LoD) and setting appropriate threshold values for data processing, thereby helping to flag incorrect resultsand addressing a challenge in SP-ICP-MS analysis. Significance: This is the first study to evaluate peak height as an analytical signal in SP-ICP-MS. The results highlight its advantages in specific applications, such as sizing NPs near the LoD, and in supporting the more reliable use of other signals, such as peak areas, by helping to identify incorrect threshold selection that could lead to biased distributions. Finally, monitoring peak heights allows for a more realistic and assumption-free determination of the LoD.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Discrete Entity Analysis via Microwave-Induced Nitrogen Plasma–Mass Spectrometry in Single-Event Mode

  • Rua-Ibarz, Ana
  • Nakadi, Flávio V.
  • Bolea-Fernandez, Eduardo
  • Bazo, Antonio
  • Battistella, Beatrice
  • Matiushkina, Anna
  • Resch-Genger, Ute
  • Abad, Carlos
  • Resano, Martín
In this work, single-event microwave-induced nitrogen plasma–mass spectrometry (single-event MINP-MS) was evaluated for the first time for the analysis of discrete entities such as nanoparticles, biological cells, and microplastics. Nitrogen (N2) effectively overcomes Ar-based polyatomic interferences, enabling (ultra)trace element determination of Fe and Se using their most abundant isotopes, 56Fe (91.66%) and 80Se (49.82%). Iron oxide nanoparticles (Fe2O3 NPs) ranging from 20 to 70 nm were accurately characterized, with excellent agreement with established sizing techniques, such as transmission electron microscopy (TEM) and dynamic light scattering (DLS). A limit of detection (LoD) of 8.6 ag for Fe─equivalent to an LoDsize of 19 nm for Fe2O3─was achieved, which is significantly lower than recent values reported for high-end quadrupole-based ICP-MS. Selenium nanoparticles (SeNPs) of 150 and 250 nm were also accurately characterized, without the N2-based plasma experiencing issues handling relatively large metallic NPs (linearity, R2 = 0.9994). Se-enriched yeast cells (SELM-1 certified reference material) were successfully analyzed via single-cell MINP-MS using external calibration based on SeNPs and a transport efficiency-independent approach. In addition, 2–3 μm polystyrene (PS) and polytetrafluoroethylene (PTFE) were accurately sized by monitoring 12C+, confirming the method’s suitability for handling micrometer-sized polymeric materials (microplastics). The average duration of individual events (680 ± 160 μs) suggests that the digestion of individual entities in N2-based plasmas is comparable to that in Ar-based plasmas. These results open new avenues for this instrumentation as an alternative to ICP ionization sources, also in the context of discrete entity analysis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Single- and dual-isotopic analysis using high-resolution continuum-source graphite-furnace molecular absorption. Strategies for data selection, processing, and modeling

  • de Souza, André L. M.
  • Aramendía, Maite
  • García-Ruiz, Esperanza
  • Nakadi, Flávio V.
  • Resano, Javier
  • Resano, Martín
This work evaluates different strategies for data processing, aiming at achieving isotopic information via high-resolution continuum-source graphite-furnace molecular absorption. For this purpose, two different molecules are investigated: CaF and CaCl. In the first case, only the measurement of 44Ca and 40Ca is pursued, whereas in the second case, isotopic variations affect both elements present in the molecule (44Ca and 40Ca, but also 37Cl and 35Cl). Thus, two different approaches are proposed. For Ca isotopic analysis through the monitoring of CaF, the effects of selecting the number of detection pixels and the number of molecular spectra, as well as of using a regression approach for temporal data, are discussed. Overall, using three detector pixels and using this regression approach tend to produce the best results (0.5–1.0% RSD) for isotopic analysis via HR CS GFMAS in those situations in which the signal can be derived from two separate peaks. On the other hand, to perform simultaneous Ca and Cl isotopic analysis by monitoring CaCl, a machine-learning strategy is proposed. The performance of such a model is promising for isotopic abundances of at least 10% (median absolute percentage error of 1.21%), while the error escalates when one of the isotopes shows a lower abundance. To detect such underperforming situations in real-world settings, it is recommended to monitor the prediction uncertainty to set thresholds and flag results with poor reliability.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Direct Characterizationof Halogen-Based Microplasticsvia Single-Event ICP-Mass Spectrometry in Negative-Ion Mode

  • Bazo, Antonio
  • Bolea-Fernandez, Eduardo
  • Rua-Ibarz, Ana
  • Resano, Martín
  • Badiei, Hamid
  • Clases, David
  • Raab, Andrea
  • Feldmann, Jörg
  • Gonzalez de Vega, Raquel
Halogen-containing microplastics such as polytetrafluoroethylene (PTFE) and poly(vinyl chloride) (PVC) are analytically relevant targets, yet their selective characterization by ICP-MS remains challenging, particularly for fluoropolymers due to the limited formation of F+ in conventional positive-ion mode. Here we introduce negative-ion single-event ICP-MS as a direct strategy for particle-resolved characterization of halogen-containing microplastics by monitoring F– and Cl– on a quadrupole ICP-MS without plasma modifiers or proxy-ion chemistry. PTFE and PVC particle standards were used as well-defined model systems, with scanning electron microscopy (SEM) confirming particle morphology and size distributions. Key acquisition and instrumental conditions governing event detectability were systematically optimized, enabling reliable transient detection at a dwell time of 100 μs. Using a conventional spray-chamber configuration, size detection limits of 1.18 μm (PTFE) and 0.73 μm (PVC) were achieved, improving to 0.68 μm (PTFE) and 0.45 μm (PVC) with a high-efficiency sample introduction system. Quantification strategies for negative-mode operation, including external calibration and transport-efficiency-based workflows, were further assessed. Overall, this work establishes negative-ion mode single-event ICP-MS as a direct platform for fluorine- and chlorine-selective microplastic detection and sizing, expanding the analytical scope of particle-resolved microplastic analysis beyond indirect fluorine detection or carbon-based approaches.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

SpectralModeling for the Deconvolution of Doppler-BroadenedHR-CS GFAAS Signals for Lithium Isotope Discrimination at Trace Levels

  • de Oliveira, Maycon L.
  • Mendes, Luciana R.
  • Dias, Luis G.
  • Nakadi, Flavio V.
  • da Veiga, Marcia A. M. S.
  • Resano, Martín
Lithium isotope analysis by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) remains challenging due to the strong spectral overlap of Doppler-broadened transitions. In this work, a physically constrained spectral deconvolution approach is introduced to resolve the overlapping fine-structure components of 7Li and 6Li without reliance on empirical or data-driven calibration models. The method is based on a physically informed description of the absorption profiles, in which the Gaussian line width (ΔFWHM) and transition parameters are optimized to reproduce the experimental spectra. The approach was evaluated over the concentration range of 1–10 μg L–1 using isotope-specific calibration and validated using synthetic mixtures and certified clinical reference materials. Deconvolution of the D2 (22P3/2 ← 22S1/2) and D1 (22P1/2 ← 22S1/2) transitions enabled isotope-resolved quantification, yielding accurate and consistent results across different matrices, with recoveries ranging from 95.5 to 115.5% when carrying out the determination of Li by isotope dilution using either a single-spike or a double-spike approach. Limits of detection ranged from 0.1 to 0.2 μg L–1, while limits of quantification ranged from 0.4 to 0.7 μg L–1, demonstrating the high sensitivity of the proposed approach. The results also indicate that the analytical performance is primarily controlled by the relative contribution of each isotope to the total absorbance. While the dominant isotope is quantified more easily and with higher reliability, the deconvolution approach enabled the determination of the minor component even under situations where it is increasingly affected by noise propagation and under conditions of strong spectral overlap. Overall, the proposed strategy demonstrates that physically informed spectral modeling enables robust lithium isotope analysis by HR-CS GFAAS and provides a general framework for addressing overlapping spectral features in atomic spectrometry.