Skip to main content

METODOLOGIA DE DISEÑO DE SISTEMAS BIOMECATRONICOS. APLICACION AL DESARROLLO DE UN ROBOT PARALELO HIBRIDO PARA DIAGNOSTICO Y REHABILITACION

DPI2013-44227-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2013
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 22
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Hybrid force/position control for a 3-DOF 1T2R parallel robot: Implementation, simulations and experiments

  • Cazalilla, J.
  • Vallés Miquel, Marina|||0000-0002-6396-0098
  • Valera Fernández, Ángel|||0000-0001-6843-6394
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Díaz-Rodríguez, Miguel Ángel|||0000-0001-7243-4957
[EN] A robot interacting with the environment requires that the end effector \hboxposition is tracked and that the forces of contact are kept below certain reference values. For instance, in a rehabilitation session using a robotic device, the contact forces are limited by the allowed strength of the human limbs and their complex-joints. In these cases, a control scheme which considers both position and force control is essential to avoid damage to either the end effector or the object interacting with the robot. This paper therefore develops a real-time force/position control scheme for a three-DOF parallel robot whose end effector holds a DOF one translation (1T) and two rotations (2R). The implemented hybrid force/position control considers, as a reference, the normal force on the mobile platform, which is measured by means of a load cell installed on the platform. The position control is designed to track the orientations of the robot either in joint or task space using a model-based control scheme with identified parameters. Moreover, the force control is based on a PD action. The control scheme is developed through simulations, before being applied to an actual parallel robot. The findings show that with the implemented controller, the actual robot accomplishes the reference values for the normal force on the mobile platform, while at the same time the platform accurately follows the required angular orientation., The authors wish to thank the Plan Nacional de I+D, Comision Interministerial de Ciencia y Tecnologia (FEDER-CICYT) for the partial funding of this study under the projects DPI2011-28507-C02-01 and DPI2013-44227-R. This work was also partially supported by the Fondo Nacional de Ciencia, Tecnologia e Innovacion (FONACIT-Venezuela).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Shelf life prediction of expired vacuum-packed chilled smoked salmon based on a KNN tissue segmentation method using hyperspectral images

  • Ivorra, Eugenio|||0000-0001-6062-2061
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
  • Verdú-Amat, Samuel|||0000-0002-3910-4582
  • Barat Baviera, José Manuel|||0000-0001-8487-7114
  • Grau Meló, Raúl|||0000-0002-0540-5539
Ready-to-eat foods that does not receive a heat treatment before being consumed can be at risk of foodborne hazards and spoilage, so it would be of great interest to have a method for monitoring their safety. This work expands on and enhances previous successfully studies with hyperspectral imaging in the SW-NIR range. Specifically, a k-nearest-neighbours model was developed to classify the salmon tissue into white myocommata stripes (fat) and muscle (lean) tissue. Partial Least Squares models developed confirm that a spatial segmentation should be performed before a shelf life model can be calculated. Employing the fat spectra and only the 7 most correlated wavelengths, a support vector machine model was calculated to classify into days 0, 10, 20, 40 and 60 with 87.2% prediction accuracy. These results make the method developed very promising as a non-destructive method to analyse the shelf life of vacuum-packed chilled smoked salmon fillets., This work has been partially funded by the Instituto Nacional de Investigacion y Tecnologia Agraria y Alimentaria de Espana (INIA - Spanish National Institute for Agriculture and Food Research and Technology) through research project RTA2012-00062-C04-02, support of European FEDER funds and DPI2013-44227-R project.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Industrial robot efficient trajectory generation without collision through the evolution of the optimal trajectory

  • Rubio Montoya, Francisco José|||0000-0003-3465-702X
  • Llopis-Albert, Carlos|||0000-0002-1349-2716
  • Suñer Martinez, Josep Lluis
  • Valero Chuliá, Francisco José
[EN] An efficient algorithm is presented to obtain trajectories for industrial robots working in industrial environments. The procedure starts with the obtaining of an optimal time trajectory neglecting the presence of obstacles. When obstacles are considered, the initial trajectory (obtained by neglecting obstacles) will not be feasible and will have to evolve so that it can become a solution. In this paper, the way that it evolves until a new feasible collision-free trajectory is obtained considering the possible obstacles is described. This is a direct algorithm that works in a discrete space of trajectories, approaching the global solution as the discretization is refined. The solutions obtained are efficient trajectories near to the minimum time one and they meet the physical limitations of the robot (the maximum values of torque, power and jerk are considered for each actuator), avoid collisions, and take into account the constraint of energy consumed. Examples already published and new examples in real industrial environments have been solved to verify the working of the algorithm., This paper has been made possible thanks to support from the Spanish Ministry of Education, Culture and Sports through the Project for Research and Technological Development with ref. DPI2013-44227-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A 3-PRS parallel manipulator for ankle rehabilitation: towards a low-cost robotic rehabilitation

  • Vallés Miquel, Marina|||0000-0002-6396-0098
  • Valera Fernández, Ángel|||0000-0001-6843-6394
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Díaz-Rodríguez, Miguel Ángel|||0000-0001-7243-4957
  • Cazalilla, J.
This paper presents the design, kinematics, dynamics and control of a low-cost parallel rehabilitation robot developed at the Universitat Polit`ecnica de Valencia. Several position and force controllers have been tested to ensure accurate tracking performances. An orthopedic boot, equipped with a force sensor, has been placed over the platform of the parallel robot to perform exercises for injured ankles. Passive, active-assistive and active-resistive exercises have been implemented to train dorsi/plantar flexion, inversion and eversion ankle movements. In order to implement the controllers, the component-based middleware Orocos has been used with the advantage over other solutions that the whole scheme control can be implemented modularly. These modules are independent and can be configured and reconfigured in both configuration and runtime. This means that no specific knowledge is needed by medical staff, for example, to carry out rehabilitation exercises using this low-cost parallel robot. The integration between Orocos and ROS, with a CAD model displaying the actual position of the rehabilitation robot in real time, makes it possible to develop a teleoperation application. In addition, a teleoperated rehabilitation exercise can be performed by a specialist using a Wiimote (or any other Bluetooth device)., This work was partially financed by Plan Nacional de I+D, Comision Interministerial de Ciencia y Tecnologia (FEDER-CICYT) under the projects DPI2011-28507-C02-01 and DPI2013-44227-R. This research was also partially funded by the CDCHT-ULA Grant I-1377-13-02-F.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Fall detection based on the gravity vector using a wide-angle camera

  • Bosch Jorge, Marc
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
  • Valera Fernández, Ángel|||0000-0001-6843-6394
  • Ricolfe Viala, Carlos|||0000-0002-2980-4569
Falls in elderly people are becoming an increasing healthcare problem, since life expectancy and the number of elderly people who live alone have increased over recent decades. If fall detection systems could be installed easily and economically in homes, telecare could be provided to alleviate this problem. In this paper we propose a low cost fall detection system based on a single wide-angle camera. Wide-angle cameras are used to reduce the number of cameras required for monitoring large areas. Using a calibrated video system, two new features based on the gravity vector are introduced for fall detection. These features are: angle between the gravity vector and the line from feet to head of the human and size of the upper body. Additionally, to differentiate between fall events and controlled lying down events the speed of changes in the features is also measured. Our experiments demonstrate that our system is 97% accurate for fall detection. (C) 2014 Elsevier Ltd. All rights reserved., This work was partially financed by Programa Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad (Direccion General de Investigacion Cientifica y Tecnica, Ministerio de Economia y Competitividad) under the project DPI2013-44227-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A review of mobile robots: Concepts, methods, theoretical framework, and applications

  • Rubio Montoya, Francisco José|||0000-0003-3465-702X
  • Llopis-Albert, Carlos|||0000-0002-1349-2716
  • Valero Chuliá, Francisco José
[EN] Humanoid robots, unmanned rovers, entertainment pets, drones, and so on are great examples of mobile robots. They can be distinguished from other robots by their ability to move autonomously, with enough intelligence to react and make decisions based on the perception they receive from the environment. Mobile robots must have some source of input data, some way of decoding that input, and a way of taking actions (including its own motion) to respond to a changing world. The need to sense and adapt to an unknown environment requires a powerful cognition system. Nowadays, there are mobile robots that can walk, run, jump, and so on like their biological counterparts. Several fields of robotics have arisen, such as wheeled mobile robots, legged robots, flying robots, robot vision, artificial intelligence, and so on, which involve different technological areas such as mechanics, electronics, and computer science. In this article, the world of mobile robots is explored including the new trends. These new trends are led by artificial intelligence, autonomous driving, network communication, cooperative work, nanorobotics, friendly human-robot interfaces, safe human-robot interaction, and emotion expression and perception. Furthermore, these news trends are applied to different fields such as medicine, health care, sports, ergonomics, industry, distribution of goods, and service robotics. These tendencies will keep going their evolution in the coming years., The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This work was supported by the Spanish Ministry of Economy and Competitiveness, which has funded the DPI2013-44227-R project.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Influence of the Friction Coefficient on the Trajectory Performance for a Car-Like Robot

  • Valero Chuliá, Francisco José
  • Rubio Montoya, Francisco José|||0000-0003-3465-702X
  • Llopis-Albert, Carlos|||0000-0002-1349-2716
  • Cuadrado Iglesias, Juan Ignacio|||0000-0003-1112-823X
[EN] A collision-free trajectory planner for a car-like mobile robot moving in complex environments is introduced and the influence of the coefficient of friction on important working parameters is analyzed. The proposed planner takes into account not only the dynamic capabilities of the robot but also the behaviour of the tire. This planner is based on sequential quadratic programming algorithms and the normalized time method. Different values for the coefficient of friction have been taken following a normal Gaussian distribution to see its influence on the working parameters. The algorithm has been applied to several examples and the results show that computation times are compatible with real-time work, so the authors call them efficient generated trajectories as they avoid collisions. Besides, working parameters such as the minimum trajectory time, the maximum vehicle speed, computational time, and consumed energy have been monitored and some conclusions have been reached., This work was supportedby the Spanish Ministryof Economy and Competitiveness, which has funded the DPI2013-44227R project.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Dynamic thoracohumeral kinematics are dependent upon the etiology of the shoulder injury

  • Lopez Pascual, Juan
  • Serra Añó, Pilar
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
[EN] Obtaining kinematic patterns that depend on the shoulder injury may be important when planning rehabilitation. The main goal of this study is to explore whether the kinematic patterns of continuous and repetitive shoulder elevation motions are different according to the type of shoulder injury in question, specifically tendinopathy or rotator cuff tear, and to analyze the influence of the load handled during its assessment. For this purpose, 19 individuals with tendinopathy and 9 with rotator cuff tear performed a repetitive scaption movement that was assessed with stereophotogrammetry. Furthermore, static range of motion (ROM) and isometric strength were evaluated with a goniometer and a dynamometer, respectively. Dynamic measurements of maximum elevation (Emax), variablility of the maximum angle (VMA), maximum angular velocity (Velmax), and time to maximum velocity (tmaxvel) were found to be significantly different between the tendinopathy group (TG) and the rotator cuff tear group (RTCG). No differences were found in the ROM assessed with goniometry and the isometric strength. The effect of increasing the load placed in the hand during the scaption movement led to significant differences in Emax, VMA, tmaxvel and repeatability. Therefore, only the dynamic variables showed sufficient capability of detecting differences in functional performance associated with structural shoulder injury. The differences observed in the kinematic variables between patients with tendinopathy and rotator cuff tear seem to be related to alterations in thoracohumeral rhythm and neuromuscular control. Kinematic analysis may contribute to a better understanding of the functional impact of shoulder injuries, which would help in the assessment and treatment of shoulder pain., This work was funded by the Spanish Government, Secretaria de Estado de Investigacion, Desarrollo e Innovacion, and co-financed by EU FEDER funds (Grant DPI2013-44227-R). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Video analysis of sliding chains: A dynamic model based on variable-mass systems

  • Moreno Cano, Rafael
  • Hueso Pagoaga, José Luís
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Riera Guasp, Jaime|||0000-0002-4183-7195
This paper presents an experimental study of the dynamics of a chain sliding off of a table, using video analysis to test a theoretical model. The model consists of two variable-mass subsystems, with friction between the chain and the table and assumes that all links move at the same speed. In order to check the model, the chain position x(t) is obtained using video analysis. The smoothed function x(t) and its derivatives v(t) and a(t) are numerically computed using a local regression algorithm. In this way, the differential equation governing the motion can be directly tested, instead of comparing the position with the solution of the differential equation. Our procedure is very sensitive to deviations between the model and reality, so we can detect the point at which the chain ceases to be in tension and the model is no longer valid. This experiment shows students the limitations of simplified models and offers an opportunity to assess a model's range of validity. (C) 2015 American Association of Physics Teachers., This work has been funded by the Spanish government (Grant No. DPI2013-44227-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Mobility assessment in people with Alzheimer disease using smartphone sensors

  • Serra-Añó, Pilar
  • Pedrero, J.F.
  • Hurtado-Abellán, J.
  • Inglés, M.
  • Espí-López, G.
  • Lopez Pascual, Juan
[EN] Background Understanding the functional status of people with Alzheimer Disease (AD), both in a single (ST) and cognitive dual task (DT) activities is essential for identifying signs of early-stage neurodegeneration. This study aims to compare the performance quality of several tasks using sensors embedded in an Android device, among people at different stages of Alzheimer and people without dementia. The secondary aim is to analyze the effect of cognitive task performance on mobility tasks. Methods This is a cross-sectional study including 22 participants in the control group (CG), 18 in the group with mild AD and 22 in the group with moderate AD. They performed two mobility tests, under ST and DT conditions, which were registered using an Android device. Postural control was measured by medial-lateral and anterior-posterior displacements of the COM (MLDisp and APDisp, respectively) and gait, with the vertical and medial-lateral range of the COM (Vrange and MLrange). Further, the sit-to-stand (PStand) and turning and sit power (PTurnSit), the total time required to complete the test and the reaction time were measured. Results There were no differences between the two AD stages either for ST or DT in any of the variables (p > 0.05). Nevertheless, people at both stages showed significantly lower values of PStand and PTurnSit and larger Total time and Reaction time compared to CG (p < 0.05). Further, Vrange is also lower in CDR1G than in CG (p < 0.05). The DT had a significant deleterious effect on MLDisp in all groups (p < 0.05) and on APDisp only in moderate AD for DT. Conclusions Our findings indicate that AD patients present impairments in some key functional abilities, such as gait, turning and sitting, sit to stand, and reaction time, both in mild and moderate AD. Nevertheless, an exclusively cognitive task only influences the postural control in people with AD., This work was funded by the Spanish Government, Secretaria de Estado de Investigacion, Desarrollo e Innovacion, and co-financed by EU FEDER funds (Grant DPI2013-44227-R). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The reliability of humerothoracic angles during arm elevation depends on the representation of rotations

  • Lopez Pascual, Juan
  • Cáceres Cáceres, Magda Liliana
  • De Rosario Martínez, Helios
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
The reliability of joint rotation measurements is an issue of major interest, especially in clinical applications. The effect of instrumental errors and soft tissue artifacts on the variability of human motion measures is well known, but the influence of the representation of joint motion has not yet been studied. The aim of the study was to compare the within-subject reliability of three rotation formalisms for the calculation of the shoulder elevation joint angles. Five repetitions of humeral elevation in the scapular plane of 27 healthy subjects were recorded using a stereophotogrammetry system. The humerothoracic joint angles were calculated using the YX'Y '' and XZ'Y '' Euler angle sequences and the attitude vector. A within-subject repeatability study was performed for the three representations. ICC, SEM and CV were the indices used to estimate the error in the calculation of the angle amplitudes and the angular waveforms with each method. Excellent results were obtained in all representations for the main angle (elevation), but there were remarkable differences for axial rotation and plane of elevation. The YX'Y '' sequence generally had the poorest reliability in the secondary angles. The XZ'Y' sequence proved to be the most reliable representation of axial rotation, whereas the attitude vector had the highest reliability in the plane of elevation. These results highlight the importance of selecting the method used to describe the joint motion when within-subjects reliability is an important issue of the experiment. This may be of particular importance when the secondary angles of motions are being studied., This work was funded by the Spanish Government and co-financed by EU FEDER funds (Grant DPI2013-44227-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Design and Kinematic Analysis of a Novel 3UPS/RPU Parallel Kinematic Mechanism With 2T2R Motion for Knee Diagnosis and Rehabilitation Tasks

  • Araujo-Gómez, Pedro
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Díaz-Rodríguez, Miguel Ángel|||0000-0001-7243-4957
  • Valera Fernández, Ángel|||0000-0001-6843-6394
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
[EN] This paper proposes a two translational and two rotational (2T2R) four-degrees-of-freedom (DOF) parallel kinematic mechanism (PKM) designed as a knee rehabilitation and diagnosis mechatronics system. First, we establish why rehabilitation devices with 2T2R motion are required, and then, we review previously proposed parallel mechanisms with this type of motion. After that, we develop a novel proposal based on the analysis of each kinematic chain and the Gr€ubler¿Kutzbach criterion. Consequently, the proposal consists of a central limb with revolute-prismatic-universal (RPU) joints and three external limbs with universal-prismatic-spherical (UPS) joints. The Screw theory analysis verifies the required mobility of the mechanism. Also, closed-loop equations enable us to put forward the closed-form solution for the inverse-displacement model, and a numerical solution for the forward-displacement model. A comparison of the numerical results from five test trajectories and the solution obtained using a virtual prototype built in MSC-ADAMS shows that the kinematic model represents the mechanism¿s motion. The analysis of the forward-displacement problem highlights the fact that the limbs of the mechanism should be arranged asymmetrically. Moreover, the Screw theory makes it possible to obtain the Jacobian matrix which provides insights into the analysis of the mechanism¿s workspace. The results show that the proposed PKM can cope with the required diagnosis and rehabilitation task. The results provide the guidelines to build a first prototype of the mechanism which enables us to perform initial tests on the robot., This work was partially funded by the Plan Nacional de I+D, Comision Interministerial de Ciencia y Tecnologia (FEDER-CICYT), Spain under the project No. DPI2013-44227-R. Also, this work was partially funded by Programa de Intercambio Cientifico (Scientific Exchange Program) of Universidad de los Andes, Venezuela.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Mechatronic design, experimental setup, and control architecture design of a novel 4 DoF parallel manipulator

  • Vallés Miquel, Marina|||0000-0002-6396-0098
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Valera Fernández, Ángel|||0000-0001-6843-6394
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Araujo-Gómez, P.
  • Díaz-Rodríguez, Miguel
  • Farhat, Nidal
[EN] Although parallel manipulators started with the introduction of architectures with six degrees of freedom, a vast number of applications require less than six degrees of freedom. Consequently, scholars have proposed architectures with three and four degrees of freedom, but relatively few four degrees of freedom parallel manipulators have become prototypes, especially of the two rotation and two translation motion types. In this article, we explain the mechatronics design, prototype, and control architecture design of a four degrees of freedom parallel manipulators with two rotation and two translation motions. We chose to design a four degrees of freedom manipulator based on the motion needed to complete the tasks of lower limb rehabilitation. To the author's best knowledge, parallel manipulators between three and six degrees of freedom for rehabilitation of lower limb have not been proposed to date. The developed architecture enhances the three minimum degrees of freedom required by adding a four degrees of freedom, which allows combinations of normal or tangential efforts in the joints, or torque acting on the knee. We put forward the inverse and forward displacement equations, describe the prototype, perform the experimental setup, and develop the hardware and control architecture. The tracking accuracy experiments from the proposed controller show that the manipulator can accomplish the required application., The authors wish to thank the Plan Nacional de I + D, Comision Interministerial de Ciencia y Tecnologia (FEDER-CICYT) for the partial funding of this study under project DPI2013-44227-R. We also want to thank the Fondo Nacional de Ciencia, Tecnologia e Innovacion (FONACIT-Venezuela) for its financial support under the project No. 2013002165.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Controller-observer design and dynamic parameter identification for model-based control of an electromechanical lower-limb rehabilitation system

  • Valera Fernández, Ángel|||0000-0001-6843-6394
  • Díaz-Rodríguez, Miguel Ángel|||0000-0001-7243-4957
  • Vallés Miquel, Marina|||0000-0002-6396-0098
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Oliver, E.
[EN] Rehabilitation is a hazardous task for a mechanical system, since the device has to interact with the human extremities without the hands-on experience the physiotherapist acquires over time. A gap needs to be filled in terms of designing effective controllers for this type of devices. In this respect, the paper describes the design of a model-based control for an electromechanical lower-limb rehabilitation system based on a parallel kinematic mechanism. A controller-observer was designed for estimating joint velocities, which are then used in a hybrid position/force control scheme. The model parameters are identified by customising an approach based on identifying only the relevant system dynamics parameters. Findings obtained through simulations show evidence of improvement in tracking performance compared with those where the velocity was estimated by numerical differentiation. The controller is also implemented in an actual electromechanical system for lower-limb rehabilitation tasks. Findings based on rehabilitation tasks confirm the findings from simulations., This work was partially financed by the Plan Nacional de I+D, Comision Interministerial de Ciencia y Tecnologia (FEDERCICYT) under the project DPI2013-44227-R and by the Instituto U. de Automatica e Informatica Industrial (ai2) of the Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Dynamic Parameter Identification of Subject-Specific Body Segment Parameters Using Robotics Formalism: Case Study Head Complex

  • Diaz-Rodriguez, Miguel
  • Page, Alvaro
  • Besa, Antonio
  • Mata, Vicente
  • Valera Fernández, Ángel|||0000-0001-6843-6394
Accurate knowledge of body segment inertia parameters (BSIP) improves the assessment of dynamic analysis based on biomechanical models, which is of paramount importance in fields such as sport activities or impact crash test. Early approaches for BSIP identification rely on the experiments conducted on cadavers or through imaging techniques conducted on living subjects. Recent approaches for BSIP identification rely on inverse dynamic modeling. However, most of the approaches are focused on the entire body, and verification of BSIP for dynamic analysis for distal segment or chain of segments, which has proven to be of significant importance in impact test studies, is rarely established. Previous studies have suggested that BSIP should be obtained by using subject-specific identification techniques. To this end, our paper develops a novel approach for estimating subject-specific BSIP based on static and dynamics identification models (SIM, DIM). We test the validity of SIM and DIM by comparing the results using parameters obtained from a regression model proposed by De Leva (1996, "Adjustments to Zatsiorsky-Seluyanov's Segment Inertia Parameters," J. Biomech., 29(9), pp. 1223-1230). Both SIM and DIM are developed considering robotics formalism. First, the static model allows the mass and center of gravity (COG) to be estimated. Second, the results from the static model are included in the dynamics equation allowing us to estimate the moment of inertia (MOI). As a case study, we applied the approach to evaluate the dynamics modeling of the head complex. Findings provide some insight into the validity not only of the proposed method but also of the application proposed by De Leva (1996, " Adjustments to Zatsiorsky-Seluyanov's Segment Inertia Parameters," J. Biomech., 29(9), pp. 1223-1230) for dynamic modeling of body segments., This work was funded by the Spanish Government and co-financed by EU FEDER funds (Grant No. DPI2013-44227-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Dual Quaternions as Constraints in 4D-DPM Models for Pose Estimation

  • Martínez Bertí, Enrique
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
  • Ricolfe Viala, Carlos|||0000-0002-2980-4569
This work was partially financed by Plan Nacional de Investigacion y Desarrollo (I+D), Comision Interministerial de Ciencia y Tecnologia (FEDER-CICYT) under the project DPI2013-44227-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Analytical study of the effects of soft tissue artefacts on functional techniques to define axes of rotation

  • De Rosario Martínez, Helios
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Besa Gonzálvez, Antonio José|||0000-0002-7084-9937
[EN] The accurate location of the main axes of rotation (AoR) is a crucial step in many applications of human movement analysis. There are different formal methods to determine the direction and position of the AoR, whose performance varies across studies, depending on the pose and the source of errors. Most methods are based on minimizing squared differences between observed and modelled marker positions or rigid motion parameters, implicitly assuming independent and uncorrelated errors, but the largest error usually results from soft tissue artefacts (STA), which do not have such statistical properties and are not effectively cancelled out by such methods. However, with adequate methods it is possible to assume that STA only account for a small fraction of the observed motion and to obtain explicit formulas through differential analysis that relate STA components to the resulting errors in AoR parameters. In this paper such formulas are derived for three different functional calibration techniques (Geometric Fitting, mean Finite Helical Axis, and SARA), to explain why each technique behaves differently from the others, and to propose strategies to compensate for those errors. These techniques were tested with published data from a sit-to-stand activity, where the true axis was defined using bi-planar fluoroscopy. All the methods were able to estimate the direction of the AoR with an error of less than 5 degrees whereas there were errors in the location of the axis of 30-40 mm. Such location errors could be reduced to less than 17 mm by the methods based on equations that use rigid motion parameters (mean Finite Helical Axis, SARA) when the translation component was calculated using the three markers nearest to the axis. (C) 2017 Elsevier Ltd. All rights reserved., This work was funded by the Spanish Government and co-financed by EU FEDER funds (Grant DPI2013-44227-R). We would like to thank Prof. Tung-Wu Lu, Tsung-Yuan Tsai, Mei-Ying Kuo and Horn-Chaung Hsu from National Taiwan University for making the data from their studies available for further research on STA,, and Dr. Tecla Bonci from the Italian University of Sport and Movement 'Foro Italico' for providing the access to benchmark data.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Kinematic Design of a New Four Degree-of-Freedom Parallel Robot for Knee Rehabilitation

  • Aginaga, J.
  • Iriarte Goñi, X.
  • Plaza, A.
  • Mata Amela, Vicente|||0000-0003-2255-0567
[EN] Rehabilitation robots are increasingly being developed in order to be used by injured people to perform exercise and training. As these exercises do not need wide range movements, some parallel robots with lower mobility architecture can be an ideal solution for this purpose. This paper presents the design of a new four degree-of-freedom (DOF) parallel robot for knee rehabilitation. The required four DOFs are two translations in a vertical plane and two rotations, one of them around an axis perpendicular to the vertical plane and the other one with respect to a vector normal to the instantaneous orientation of the mobile platform. These four DOFs are reached by means of two RPRR limbs and two UPS limbs linked to an articulated mobile platform with an internal DOF. Kinematics of the new mechanism are solved and the direct Jacobian is calculated. A singularity analysis is carried out and the gained DOFs of the direct singularities are calculated. Some of the singularities can be avoided by selecting suitable values of the geometric parameters of the robot. Moreover, among the found singularities, one of them can be used in order to fold up the mechanism for its transportation. it is concluded that the proposed mechanism reaches the desired output movements in order to carry out rehabilitation maneuvers in a singularity-free portion of its workspace., This work was funded by the Plan Nacional de I + D, Comision Interministerial de Ciencia y Tecnologia (FEDER-CICYT) under the projects DPI2013-44227-R and DPI2017-84201-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

4-Dimensional deformation part model for pose estimation using Kalman filter constraints

  • Martínez Bertí, Enrique
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
  • Ricolfe Viala, Carlos|||0000-0002-2980-4569
[EN] The goal of this research work is to improve the accuracy of human pose estimation using the deformation part model without increasing computational complexity. First, the proposed method seeks to improve pose estimation accuracy by adding the depth channel to deformation part model, which was formerly defined based only on RGB channels, to obtain a 4-dimensional deformation part model. In addition, computational complexity can be controlled by reducing the number of joints by taking into account in a reduced 4-dimensional deformation part model. Finally, complete solutions are obtained by solving the omitted joints by using inverse kinematic models. The main goal of this article is to analyze the effect on pose estimation accuracy when using a Kalman filter added to 4-dimensional deformation part model partial solutions. The experiments run with two data sets showing that this method improves pose estimation accuracy compared with state-of-the-art methods and that a Kalman filter helps to increase this accuracy., The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This work was partially financed by Plan Nacional de I + D, Comision Interministerial de Ciencia y Tecnologa (FEDERCICYT) under the project DPI2013-44227-R.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Movement Variability Increases With Shoulder Pain When Compensatory Strategies of the Upper Body Are Constrained

  • Lopez Pascual, Juan
  • Serra Añó, Pilar
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
[DE] This cross-sectional study analyzed the influence of chronic shoulder pain (CSP) on movement variability/kinematics during humeral elevation, with the trunk and elbow motions constrained to avoid compensatory strategies. For this purpose, 37 volunteers with CSP as the injured group (IG) and 58 participants with asymptomatic shoulders as the control group (CG) participated in the study. Maximum humeral elevation (Emax), maximum angular velocity (Velmax), variability of the maximum angle (CVEmax), functional variability (Func_var), and approximate entropy (ApEn) were calculated from the kinematic data. Patients' pain was measured on the visual analogue scale (VAS). Compared with the CG, the IG presented lower Emax and Velmax and higher variability (i.e., CVEmax, Func_var, and ApEn). Moderate correlations were achieved for the VAS score and the kinematic variables Emax, Velmax and variability of curve analysis, Func_varm, and ApEn. No significant correlation was found for CVEmax. In conclusion, CSP results in a decrease of angle and velocity and an increased shoulder movement variability when the neuromuscular system cannot use compensatory strategies to avoid painful positions., This work was funded by the Spanish Government and cofinanced by EU FEDER funds (Grant DPI2013-44227-R)
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Determination of the symbolic base inertial parameters of planar mechanisms

  • Iriarte Goñi, Xabier
  • Ros Ganuza, Javier
  • Mata, Vicente
  • Aginaga García, Jokin
The inertial information of a planar mechanical system is characterised using 4 inertial parameters per solid. Due to the kinematic constraints, this parametrisation turns out be redundant. In order to reduce the computational cost of the model and make it possible to estimate its inertial parameters, the model is usually written in terms of a minimum set of inertial parameters called base inertial parameters. These parameters completely determine the dynamics of motion (kinetics) of a mechanism and, since their contributions are independent to each other, their actual values can be estimated experimentally. The base inertial parameters expressions can be written as a linear combination of the inertial parameters and determining their symbolic expressions provides a deeper insight into their physical meaning. This paper presents a new algorithm to determine the symbolic expressions of the base inertial parameters of planar mechanisms. The approach is based on a very well known numerical method to obtain the base inertial parameters and on the fact that these parameters belong to a class of functions that lets us search for symbolic expressions matching with them. Since the symbolic expressions are a function of the geometric constants of the system, the presented algorithm constitutes a very valuable tool in design optimisation and it is also very interesting in dynamic parameter estimation, model reduction and other fields., This paper has been possible owing to the funding from The Ministry of Economy and Competitiveness of the Spanish Government by means of the Research and Technological Development Project DPI2013-44227-R (MEDIOMEC).
Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
Publication Artículo científico (JournalArticle)

Kinematic design of a new four degree-of-freedom parallel robot for knee rehabilitation

  • Aginaga García, Jokin
  • Iriarte Goñi, Xabier
  • Plaza Puértolas, Aitor
  • Mata, Vicente
Rehabilitation robots are increasingly being developed in order to be used by injured people to perform exercise and training. As these exercises do not need wide range movements, some parallel robots with lower mobility architecture can be an ideal solution for this purpose. This paper presents the design of a new four degree-of-freedom (DOF) parallel robot for knee rehabilitation. The required four DOFs are two translations in a vertical plane and two rotations, one of them around an axis perpendicular to the vertical plane and the other one with respect to a vector normal to the instantaneous orientation of the mobile platform. These four DOFs are reached by means of two RPRR limbs and two UPS limbs linked to an articulated mobile platform with an internal DOF. Kinematics of the new mechanism are solved and the direct Jacobian is calculated. A singularity analysis is carried out and the gained DOFs of the direct singularities are calculated. Some of the singularities can be avoided by selecting suitable values of the geometric parameters of the robot. Moreover, among the found singularities, one of them can be used in order to fold up the mechanism for its transportation. It is concluded that the proposed mechanism reaches the desired output movements in order to carry out rehabilitation maneuvers in a singularity-free portion of its workspace., This work was funded by the Plan Nacional de I + D, Comisión Interministerial de Ciencia y Tecnología (FEDER-CICYT) under the projects DPI2013-44227-R and DPI2017-84201-R.