Skip to main content

DESARROLLO Y VALIDACION DE SISTEMAS DE DETECCION DE FALLOS Y DISEÑO DE ESTRATEGIAS DE CONTROL TOLERANTE A FALLOS CON APLICACION A PLANTAS DE ENERGIA EOLICA OFFSHORE

DPI2014-58427-C2-1-R

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2014
State Plan 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Management unit Secretaría de Estado de Educación, Formación Profesional y Universidades
Beneficiary centre UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Hysteresis-based design of dynamic reference trajectories to avoid saturation in controlled wind turbines

  • Tutivén Gálvez, Christian|||0000-0001-6322-4608
  • Vidal Seguí, Yolanda|||0000-0003-4964-6948
  • Acho Zuppa, Leonardo|||0000-0002-4965-1133
  • Rodellar Benedé, José|||0000-0002-1514-7713
The main objective of this paper is to design a dynamic reference trajectory based on hysteresis to avoid saturation in controlled wind turbines. Basically, the torque controller and pitch controller set-points are hysteretically manipulated to avoid saturation and drive the system with smooth dynamic changes. Simulation results obtained from a 5MW wind turbine benchmark model show that our proposed strategy has a clear added value with respect to the baseline controller (a well-known and accepted industrial wind turbine controller). Moreover, the proposed strategy has been tested in healthy conditions but also in the presence of a realistic fault where the baseline controller caused saturation to nally conduct to instability., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

A sensor data fusion system based on k-nearest neighbor pattern classification for structural health monitoring applications

  • Vitola Oyaga, Jaime
  • Pozo Montero, Francesc|||0000-0001-8958-6789
  • Tibaduiza Burgos, Diego Alexander
  • Anaya Vejar, Maribel
Civil and military structures are susceptible and vulnerable to damage due to the environmental and operational conditions. Therefore, the implementation of technology to provide robust solutions in damage identification (by using signals acquired directly from the structure) is a requirement to reduce operational and maintenance costs. In this sense, the use of sensors permanently attached to the structures has demonstrated a great versatility and benefit since the inspection system can be automated. This automation is carried out with signal processing tasks with the aim of a pattern recognition analysis. This work presents the detailed description of a structural health monitoring (SHM) system based on the use of a piezoelectric (PZT) active system. The SHM system includes: (i) the use of a piezoelectric sensor network to excite the structure and collect the measured dynamic response, in several actuation phases; (ii) data organization; (iii) advanced signal processing techniques to define the feature vectors; and finally; (iv) the nearest neighbor algorithm as a machine learning approach to classify different kinds of damage. A description of the experimental setup, the experimental validation and a discussion of the results from two different structures are included and analyzed., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

A sensor data fusion system based on k-nearest neighbor pattern classification for structural health monitoring applications

  • Vitola Oyaga, Jaime
  • Pozo Montero, Francesc
  • Tibaduiza Burgos, Diego Alexander
  • Anaya Vejar, Maribel
Civil and military structures are susceptible and vulnerable to damage due to the environmental and operational conditions. Therefore, the implementation of technology to provide robust solutions in damage identification (by using signals acquired directly from the structure) is a requirement to reduce operational and maintenance costs. In this sense, the use of sensors permanently attached to the structures has demonstrated a great versatility and benefit since the inspection system can be automated. This automation is carried out with signal processing tasks with the aim of a pattern recognition analysis. This work presents the detailed description of a structural health monitoring (SHM) system based on the use of a piezoelectric (PZT) active system. The SHM system includes: (i) the use of a piezoelectric sensor network to excite the structure and collect the measured dynamic response, in several actuation phases; (ii) data organization; (iii) advanced signal processing techniques to define the feature vectors; and finally; (iv) the nearest neighbor algorithm as a machine learning approach to classify different kinds of damage. A description of the experimental setup, the experimental validation and a discussion of the results from two different structures are included and analyzed., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Hysteresis-based design of dynamic reference trajectories to avoid saturation in controlled wind turbines

  • Tutivén Gálvez, Christian
  • Vidal Seguí, Yolanda
  • Acho Zuppa, Leonardo
  • Rodellar Benedé, José
The main objective of this paper is to design a dynamic reference trajectory based on hysteresis to avoid saturation in controlled wind turbines. Basically, the torque controller and pitch controller set-points are hysteretically manipulated to avoid saturation and drive the system with smooth dynamic changes. Simulation results obtained from a 5MW wind turbine benchmark model show that our proposed strategy has a clear added value with respect to the baseline controller (a well-known and accepted industrial wind turbine controller). Moreover, the proposed strategy has been tested in healthy conditions but also in the presence of a realistic fault where the baseline controller caused saturation to nally conduct to instability., Peer Reviewed, Postprint (author's final draft)