Skip to main content

INGENIERIA FOTONICA PARA EL DIAGNOSTICO, SEGUIMIENTO Y TRATAMIENTO DE ENFERMEDADES OCULARES Y SANGUINEAS

DPI2017-89414-R

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos I+D+i Retos de Investigación
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSITAT POLITECNICA DE CATALUNYA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 26
Encontrada(s) 1 página(s)

UPCommons. Portal del coneixement obert de la UPC
Publication Capítulo o parte de un libro (BookPart)

Visible and extended near-infrared multispectral imaging for skin cancer diagnosis

  • Rey Barroso, Laura|||0000-0002-6305-0609
  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Delpueyo, Xana
  • Ares Rodríguez, Miguel|||0000-0001-5710-823X
  • Royo Royo, Santiago|||0000-0003-0136-8301
  • Malvehy Guilera, Josep
  • Puig, Susana
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
With the goal of diagnosing skin cancer in an early and noninvasive way, an extended near infrared multispectral imaging system based on an InGaAs sensor with sensitivity from 995 nm to 1613 nm was built to evaluate deeper skin layers thanks to the higher penetration of photons at these wavelengths. The outcomes of this device were combined with those of a previously developed multispectral system that works in the visible and near infrared range (414 nm–995 nm). Both provide spectral and spatial information from skin lesions. A classification method to discriminate between melanomas and nevi was developed based on the analysis of first-order statistics descriptors, principal component analysis, and support vector machine tools. The system provided a sensitivity of 78.6% and a specificity of 84.6%, the latter one being improved with respect to that offered by silicon sensors., This research was supported by the Spanish Ministry of Economy and Competitiveness under the grant DPI2014-56850-R, DPI2017-89414-R, and by the European Union through the project DIAGNOPTICS ‘diagnosis of skin cancer using optics’ (ICT PSP seventh call for proposals 2013)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Estudio espectroscópico de glóbulos rojos mediante microscopía confocal en pacientes con talasemia: resultados preliminares

  • Rey Barroso, Laura|||0000-0002-6305-0609
  • Roldán Molina, Mónica
  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Gassiot Riu, Susanna
  • Ruiz Llobet, Anna
  • Isola, Ignacio
  • Pujol Ramo, Jaume|||0000-0003-0811-9244
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Multispectral retinography in healthy adult population

  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Alterini, Tommaso|||0000-0002-8922-8970
  • Díaz Douton, Fernando|||0000-0003-3699-015X
  • Bou Marín, Marina
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
Spectral reflectance of the eye fundus was evaluated in adult healthy patients through a fast visible and near-infrared multispectral fundus camera. Spectral signatures were analyzed for different ocular structures of the retina and the choroid., This project has received funding from the European Union's Horizon 2020 research and innovation programme under Marie Skłodowska-Curie grant agreement No. 801342 (Tecniospring INDUSTRY) and the Government of Catalonia's Agency for Business Competitiveness (ACCIÓ). This research was also supported by the Ministerio de Economía, Industria y Competitividad (MINECO), the Agencia Estatal de Investigación (AEI) and the European Regional Development Fund (FEDER) under the grant DPI2017-89414-R., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Membrane protein detection and morphological analysis of red blood cells in hereditary spherocytosis by confocal laser scanning microscopy

  • Rey Barroso, Laura|||0000-0002-6305-0609
  • Roldán Molina, Mónica
  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Isola, Ignacio Mario
  • Ruiz Llobet, Anna
  • Gassiot Riu, Susanna
  • Sarrate Garcia, Edurne
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
In hereditary spherocytosis (HS), genetic mutations in the cell membrane and cytoskeleton proteins cause structural defects in red blood cells (RBCs). As a result, cells are rigid and misshapen, usually with a characteristic spherical form (spherocytes), too stiff to circulate through microcirculation regions, so they are prone to undergo hemolysis and phagocytosis by splenic macrophages. Mild to severe anemia arises in HS, and other derived symptoms like splenomegaly, jaundice, and cholelithiasis. Although abnormally shaped RBCs can be identified under conventional light microscopy, HS diagnosis relies on several clinical factors and sometimes on the results of complex molecular testing. It is specially challenging when other causes of anemia coexist or after recent blood transfusions. We propose two different approaches to characterize RBCs in HS: (i) an immunofluorescence assay targeting protein band 3, which is affected in most HS cases and (ii) a three-dimensional morphology assay, with living cells, staining the membrane with fluorescent dyes. Confocal laser scanning microscopy (CLSM) was used to carry out both assays, and in order to complement the latter, a software was developed for the automated detection of spherocytes in blood samples. CLSM allowed the precise and unambiguous assessment of cell shape and protein expression., This publication is part of the project PID2020-112527RBI00, funded by CIN/AEI/10.13039/501100011033. Laura Rey-Barroso thanks the Ministry of Science, Innovation and Universities for the PhD (FPI) grant she has received (DPI2017-89414-R). The current study has been funded by the Spanish National Agency of Investigation (AEI)., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Multispectral retinography in healthy adult population

  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Alterini, Tommaso|||0000-0002-8922-8970
  • Díaz Douton, Fernando|||0000-0003-3699-015X
  • Bou Marín, Marina
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
Spectral reflectance of the eye fundus was evaluated in adult healthy patients through a fast visible and near-infrared multispectral fundus camera. Spectral signatures were analyzed for different ocular structures of the retina and the choroid., This project has received funding from the European Union's Horizon 2020 research and innovation programme under Marie Skłodowska-Curie grant agreement No. 801342 (Tecniospring INDUSTRY) and the Government of Catalonia's Agency for Business Competitiveness (ACCIÓ). This research was also supported by the Ministerio de Economía, Industria y Competitividad (MINECO), the Agencia Estatal de Investigación (AEI) and the European Regional Development Fund (FEDER) under the grant DPI2017-89414-R., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Spectroscopic evaluation of red blood cells of thalassemia patients with confocal microscopy: a pilot study

  • Rey Barroso, Laura|||0000-0002-6305-0609
  • Roldan, Monica
  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Gassiot Riu, Susanna
  • Ruiz Llobet, Anna
  • Isola, Ignacio
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
Hemoglobinopathies represent the most common single-gene defects in the world and pose a major public health problem, particularly in tropical countries, where they occur with high frequency. Diagnosing hemoglobinopathies can sometimes be difficult due to the coexistence of different causes of anemia, such as thalassemia and iron deficiency, and blood transfusions, among other factors, and requires expensive and complex molecular tests. This work explores the possibility of using spectral confocal microscopy as a diagnostic tool for thalassemia in pediatric patients, a disease caused by mutations in the globin genes that result in changes of the globin chains that form hemoglobin—in pediatric patients. Red blood cells (RBCs) from patients with different syndromes of alpha-thalassemia and iron deficiency (including anemia) as well as healthy (control) subjects were analyzed under a Leica TCS SP8 confocal microscope following different image acquisition protocols. We found that diseased RBCs exhibited autofluorescence when excited at 405 nm and their emission was collected in the spectral range from 425 nm to 790 nm. Three experimental descriptors calculated from the mean emission intensities at 502 nm, 579 nm, 628 nm, and 649 nm allowed us to discriminate between diseased and healthy cells. According to the results obtained, spectral confocal microscopy could serve as a tool in the diagnosis of thalassemia., This research was funded by Spanish Ministry of Economy and Competitiveness, grant number DPI2017-89414-R. L.R.-B. thanks the Ministry of Science, Innovation and Universities for the PhD (FPI) grant she has received., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Morphological study of skin cancer lesions through a 3D scanner based on fringe projection and machine learning

  • Rey Barroso, Laura|||0000-0002-6305-0609
  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Ares Rodríguez, Miguel|||0000-0001-5710-823X
  • Royo Royo, Santiago|||0000-0003-0136-8301
  • Puig, Susana
  • Malvehy Guilera, José
  • Pellacani, Giovanni
  • Espinar Martínez, Daniel
  • Sicília Armengol, Natàlia
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
UPCommons. Portal del coneixement obert de la UPC
Publication Contribución de congreso (ConferenceOutput)

Colorimetric analysis of eye fundus structures with multispectral retinography

  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Alterini, Tommaso|||0000-0002-8922-8970
  • Díaz Douton, Fernando|||0000-0003-3699-015X
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
The analysis of the eye fundus is critical to prevent retinal and choroidal diseases since most of them cause no symptoms at early stages. Treating them when the very first signs appear is crucial to avoid vision losses. To this end, the color of eye fundus structures of healthy and diseased patients was assessed from images acquired with a novel multispectral fundus camera (400 nm – 1300 nm) with high spectral and spatial resolution. Characteristic color traits were found: in healthy eyes, large CIEDE2000 color differences were reported between arteries and veins due to different blood oxygenation; the contrast of nerve fibers/fovea was enhanced, giving rise to relevant color differences; in eyes with age related macular degeneration, lesions such as drusen could be better distinguished than with traditional color retinography; alterations of the optic disk in patients with glaucoma were also assessed, showing remarkable CIEDE2000 values when compared to healthy patients, This project has received funding from the European Union's Horizon 2020 research and innovation programme under Marie Skłodowska-Curie grant agreement No. 801342 (Tecniospring INDUSTRY) and the Government of Catalonia's Agency for Business Competitiveness (ACCIÓ). This research was also supported by the Ministerio de Economía, Industria y Competitividad (MINECO), the Agencia Estatal de Investigación (AEI) and the European Regional Development Fund (FEDER) under the grant DPI2017-89414-R., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Transmittance measurement of the in vivo human eye with a double-pass system

  • Sánchez, Roberto
  • De Paul, Aníbal
  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
  • Pujol Ramo, Jaume|||0000-0003-0811-9244
  • Issolio, Luis A.
Purpose: To develop a methodology based on a double-pass system to obtain information about the transmittance of ocular media. Methods: The procedure consists of recording double-pass images at different powers of a laser diode of 780 nm and determining the scattering in an area between 25–35 arcmin of each image. The scattering showed linear behavior in respect to the irradiance of the laser, and the slope of the linear fit was proportional to the transmittance squared of the media evaluated. An artificial eye with different filters was tested first. Then, fifteen subjects with clear ocular media were divided into two groups: ten subjects classified by the iris color were recruited for the measurements of an ocular transmittance index and the estimation of the transmittance (group A), and another five subjects were selected for measurements with neutral filters (group B). Results: The measurements performed in group A presented a mean transmittance of 42.95%. No differences in the transmittance were found between subjects with different iris color ( p = 0.154). Measurements in group B showed a good correlation (r = 0.959, p < 0.001) between the expected and the measured value for the transmittance. Conclusion: We proposed and evaluated a method to determine the transmittance of the eye in vivo using the double-pass system., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Characteristics of saccades during the near point of convergence test

  • Mestre Ferrer, Clara|||0000-0003-0053-550X
  • Bedell, Harold E.
  • Díaz Douton, Fernando|||0000-0003-3699-015X
  • Pujol Ramo, Jaume|||0000-0003-0811-9244
  • Gautier, Josselyn
The near point of convergence test is widely used to evaluate binocular vision. It assesses the ability of the eyes to converge at short distances. Although the test consists of a pure symmetrical vergence task, small involuntary saccades occur concurrently. The main goal of this study was to analyze saccadic characteristics as a function of vergence demand when testing the near point of convergence. To this purpose, the eye movements of 11 participants were registered with an eye-tracker while they performed the near point of convergence test by following a target that traveled forward and backward on a motorized bench. Saccade amplitude increased and, on average, saccade rate decreased with vergence demand. In general, the direction of the concurrent vergence movement had no significant effect on saccade characteristics. However, each individual subject showed idiosyncratic behavior. Most saccades tended to be corrective in terms of both binocular disparity and individual fixation position errors. In particular, most participants tended to correct the fixation position error of the dominant eye., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Implementation of the frequency scatter index in clinical commercially available double-pass systems

  • Sánchez, Roberto F
  • García Guerra, Carlos Enrique|||0000-0001-7013-9938
  • Martínez Roda, Juan Antonio|||0000-0003-0222-7164
  • De Paul, Aníbal
  • Issolio, Luis A.
  • Pujol Ramo, Jaume|||0000-0003-0811-9244
A previous work has reported a methodology to quantify intraocular scattering using a high sensitivity double-pass instrument with a robust index, the frequency scatter index. The purpose of our study was to evaluate an adaptation of the frequency scatter index for use in clinical double-pass systems. A prospective observational study was carried out in a group of patients with nuclear cataracts (n = 52) and in a control group (n = 11) using conventional double-pass systems. The frequency scatter index and the objective scatter index were used to assess the scattering. The Spearman coefficient was calculated to assess the correlation between both indexes, obtained from the double-pass images. Simultaneous measurements were performed with a double-pass and with a Hartmann-Shack wavefront sensor in the control group. The root-mean-square wavefront error and the full width at half maximum of the double-pass image were used to quantify the residual aberrations introduced by the variations in pupil size and retinal eccentricity. Measurement in eyes with different grades of cataracts shows a strong correlation (¿ = 0.929, p < .0001) between the frequency scatter index and the objective scatter index. A certain degree of correlation was observed between the objective scatter index and the root-mean-square and between the objective scatter index and the full width at half maximum, both for measurements with a different pupillary diameter and with a different retinal eccentricity (p < .05). No relationship was observed between the frequency scatter index and the root-mean-square or between the frequency scatter index and the full width at half maximum (p > .05). We have introduced and evaluated an adaptation of a methodology proposed recently for the measurement of intraocular scattering using the double-pass technique with a robust index, which is less affected by ocular aberrations. The frequency scatter index can be applied to conventional double-pass instruments available in clinical environments., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Experimental characterization of the speckle pattern at the output of a multimode optical fiber

  • Halpaap, Donatus
  • Tiana Alsina, Jordi|||0000-0001-8359-9378
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
  • Masoller Alonso, Cristina|||0000-0003-0768-2019
Speckle patterns produced by coherent waves interfering with each other are undesirable in many imaging applications (for example, in laser projection systems) but on the other hand, they contain useful information that can be exploited (for example, for blood flow analysis or reconstruction of the object that generates the speckle). It is therefore important to understand how speckle can be enhanced or reduced by tailoring the coherence of laser light. Using a conventional semiconductor laser and a multimode optical fiber we study experimentally how the speckle pattern depends on the laser pump current and on the image acquisition settings. By varying the pump current from below to above the lasing threshold, and simultaneously tuning the image exposure time to compensate for the change in brightness, we find conditions that allow for recorded images with similar average intensity, but with speckle contrast (the standard deviation of the intensity over the average intensity) as low as 0.16, or as high as 0.99., Peer Reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Optical technologies for the improvement of skin cancer diagnosis: a review

  • Rey Barroso, Laura|||0000-0002-6305-0609
  • Peña Gutiérrez, Sara|||0000-0001-9378-5545
  • Yáñez Alvarado, Carlos René|||0000-0002-4216-3794
  • Burgos Fernández, Francisco Javier|||0000-0002-3749-6850
  • Vilaseca Ricart, Meritxell|||0000-0001-8166-1617
  • Royo Royo, Santiago|||0000-0003-0136-8301
The worldwide incidence of skin cancer has risen rapidly in the last decades, becoming one in three cancers nowadays. Currently, a person has a 4% chance of developing melanoma, the most aggressive form of skin cancer, which causes the greatest number of deaths. In the context of increasing incidence and mortality, skin cancer bears a heavy health and economic burden. Nevertheless, the 5-year survival rate for people with skin cancer significantly improves if the disease is detected and treated early. Accordingly, large research efforts have been devoted to achieve early detection and better understanding of the disease, with the aim of reversing the progressive trend of rising incidence and mortality, especially regarding melanoma. This paper reviews a variety of the optical modalities that have been used in the last years in order to improve non-invasive diagnosis of skin cancer, including confocal microscopy, multispectral imaging, threedimensional topography, optical coherence tomography, polarimetry, self-mixing interferometry, and machine learning algorithms. The basics of each of these technologies together with the most relevant achievements obtained are described, as well as some of the obstacles still to be resolved and milestones to be met., This research was supported by the Ministerio de Economía, Industria y Competitividad (MINECO), the Agencia Estatal de Investigación (AEI) and the European Regional Development Fund (FEDER) under the grants DPI2017-89414-R and FIS2017-89850-R. L.R-B. thanks the Spanish Government for the predoctoral FPI grant she received, grant number DPI2017-89414-R. S. P-G. thanks AGAUR for the FI grant she received, grant number 2020FI_B2 00068. C.Y. thanks CONACYT Mexico for the grant he received, grant number 472102, Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Estudio espectroscópico de glóbulos rojos mediante microscopía confocal en pacientes con talasemia: resultados preliminares

Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Experimental characterization of the speckle pattern at the output of a multimode optical fiber

  • Halpaap, Donatus
  • Tiana Alsina, Jordi
  • Vilaseca Ricart, Meritxell
  • Masoller Alonso, Cristina
Speckle patterns produced by coherent waves interfering with each other are undesirable in many imaging applications (for example, in laser projection systems) but on the other hand, they contain useful information that can be exploited (for example, for blood flow analysis or reconstruction of the object that generates the speckle). It is therefore important to understand how speckle can be enhanced or reduced by tailoring the coherence of laser light. Using a conventional semiconductor laser and a multimode optical fiber we study experimentally how the speckle pattern depends on the laser pump current and on the image acquisition settings. By varying the pump current from below to above the lasing threshold, and simultaneously tuning the image exposure time to compensate for the change in brightness, we find conditions that allow for recorded images with similar average intensity, but with speckle contrast (the standard deviation of the intensity over the average intensity) as low as 0.16, or as high as 0.99., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Colorimetric analysis of eye fundus structures with multispectral retinography

  • Burgos Fernández, Francisco Javier
  • Alterini, Tommaso
  • Díaz Douton, Fernando
  • Vilaseca Ricart, Meritxell
The analysis of the eye fundus is critical to prevent retinal and choroidal diseases since most of them cause no symptoms at early stages. Treating them when the very first signs appear is crucial to avoid vision losses. To this end, the color of eye fundus structures of healthy and diseased patients was assessed from images acquired with a novel multispectral fundus camera (400 nm – 1300 nm) with high spectral and spatial resolution. Characteristic color traits were found: in healthy eyes, large CIEDE2000 color differences were reported between arteries and veins due to different blood oxygenation; the contrast of nerve fibers/fovea was enhanced, giving rise to relevant color differences; in eyes with age related macular degeneration, lesions such as drusen could be better distinguished than with traditional color retinography; alterations of the optic disk in patients with glaucoma were also assessed, showing remarkable CIEDE2000 values when compared to healthy patients, This project has received funding from the European Union's Horizon 2020 research and innovation programme under Marie Skłodowska-Curie grant agreement No. 801342 (Tecniospring INDUSTRY) and the Government of Catalonia's Agency for Business Competitiveness (ACCIÓ). This research was also supported by the Ministerio de Economía, Industria y Competitividad (MINECO), the Agencia Estatal de Investigación (AEI) and the European Regional Development Fund (FEDER) under the grant DPI2017-89414-R., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Optical technologies for the improvement of skin cancer diagnosis: a review

  • Rey Barroso, Laura
  • Peña Gutiérrez, Sara
  • Yáñez Alvarado, Carlos René
  • Burgos Fernández, Francisco Javier
  • Vilaseca Ricart, Meritxell
  • Royo Royo, Santiago
The worldwide incidence of skin cancer has risen rapidly in the last decades, becoming one in three cancers nowadays. Currently, a person has a 4% chance of developing melanoma, the most aggressive form of skin cancer, which causes the greatest number of deaths. In the context of increasing incidence and mortality, skin cancer bears a heavy health and economic burden. Nevertheless, the 5-year survival rate for people with skin cancer significantly improves if the disease is detected and treated early. Accordingly, large research efforts have been devoted to achieve early detection and better understanding of the disease, with the aim of reversing the progressive trend of rising incidence and mortality, especially regarding melanoma. This paper reviews a variety of the optical modalities that have been used in the last years in order to improve non-invasive diagnosis of skin cancer, including confocal microscopy, multispectral imaging, threedimensional topography, optical coherence tomography, polarimetry, self-mixing interferometry, and machine learning algorithms. The basics of each of these technologies together with the most relevant achievements obtained are described, as well as some of the obstacles still to be resolved and milestones to be met., This research was supported by the Ministerio de Economía, Industria y Competitividad (MINECO), the Agencia Estatal de Investigación (AEI) and the European Regional Development Fund (FEDER) under the grants DPI2017-89414-R and FIS2017-89850-R. L.R-B. thanks the Spanish Government for the predoctoral FPI grant she received, grant number DPI2017-89414-R. S. P-G. thanks AGAUR for the FI grant she received, grant number 2020FI_B2 00068. C.Y. thanks CONACYT Mexico for the grant he received, grant number 472102, Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Multispectral retinography in healthy adult population

  • Burgos Fernández, Francisco Javier
  • Alterini, Tommaso
  • Díaz Douton, Fernando
  • Bou Marín, Marina
  • Vilaseca Ricart, Meritxell
Spectral reflectance of the eye fundus was evaluated in adult healthy patients through a fast visible and near-infrared multispectral fundus camera. Spectral signatures were analyzed for different ocular structures of the retina and the choroid., This project has received funding from the European Union's Horizon 2020 research and innovation programme under Marie Skłodowska-Curie grant agreement No. 801342 (Tecniospring INDUSTRY) and the Government of Catalonia's Agency for Business Competitiveness (ACCIÓ). This research was also supported by the Ministerio de Economía, Industria y Competitividad (MINECO), the Agencia Estatal de Investigación (AEI) and the European Regional Development Fund (FEDER) under the grant DPI2017-89414-R., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Morphological study of skin cancer lesions through a 3D scanner based on fringe projection and machine learning

  • Rey Barroso, Laura
  • Burgos Fernández, Francisco Javier
  • Ares Rodríguez, Miguel
  • Royo Royo, Santiago
  • Puig, Susana
  • Malvehy Guilera, José
  • Pellacani, Giovanni
  • Espinar Martínez, Daniel
  • Sicília Armengol, Natàlia
  • Vilaseca Ricart, Meritxell
Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Implementation of the frequency scatter index in clinical commercially available double-pass systems

  • Sánchez, Roberto F
  • García Guerra, Carlos Enrique
  • Martínez Roda, Juan Antonio
  • De Paul, Aníbal
  • Issolio, Luis A.
  • Pujol Ramo, Jaume
A previous work has reported a methodology to quantify intraocular scattering using a high sensitivity double-pass instrument with a robust index, the frequency scatter index. The purpose of our study was to evaluate an adaptation of the frequency scatter index for use in clinical double-pass systems. A prospective observational study was carried out in a group of patients with nuclear cataracts (n = 52) and in a control group (n = 11) using conventional double-pass systems. The frequency scatter index and the objective scatter index were used to assess the scattering. The Spearman coefficient was calculated to assess the correlation between both indexes, obtained from the double-pass images. Simultaneous measurements were performed with a double-pass and with a Hartmann-Shack wavefront sensor in the control group. The root-mean-square wavefront error and the full width at half maximum of the double-pass image were used to quantify the residual aberrations introduced by the variations in pupil size and retinal eccentricity. Measurement in eyes with different grades of cataracts shows a strong correlation (¿ = 0.929, p < .0001) between the frequency scatter index and the objective scatter index. A certain degree of correlation was observed between the objective scatter index and the root-mean-square and between the objective scatter index and the full width at half maximum, both for measurements with a different pupillary diameter and with a different retinal eccentricity (p < .05). No relationship was observed between the frequency scatter index and the root-mean-square or between the frequency scatter index and the full width at half maximum (p > .05). We have introduced and evaluated an adaptation of a methodology proposed recently for the measurement of intraocular scattering using the double-pass technique with a robust index, which is less affected by ocular aberrations. The frequency scatter index can be applied to conventional double-pass instruments available in clinical environments., Peer Reviewed, Postprint (updated version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Transmittance measurement of the in vivo human eye with a double-pass system

  • Sánchez, Roberto
  • De Paul, Aníbal
  • Burgos Fernández, Francisco Javier
  • Vilaseca Ricart, Meritxell
  • Pujol Ramo, Jaume
  • Issolio, Luis A.
Purpose: To develop a methodology based on a double-pass system to obtain information about the transmittance of ocular media. Methods: The procedure consists of recording double-pass images at different powers of a laser diode of 780 nm and determining the scattering in an area between 25–35 arcmin of each image. The scattering showed linear behavior in respect to the irradiance of the laser, and the slope of the linear fit was proportional to the transmittance squared of the media evaluated. An artificial eye with different filters was tested first. Then, fifteen subjects with clear ocular media were divided into two groups: ten subjects classified by the iris color were recruited for the measurements of an ocular transmittance index and the estimation of the transmittance (group A), and another five subjects were selected for measurements with neutral filters (group B). Results: The measurements performed in group A presented a mean transmittance of 42.95%. No differences in the transmittance were found between subjects with different iris color ( p = 0.154). Measurements in group B showed a good correlation (r = 0.959, p < 0.001) between the expected and the measured value for the transmittance. Conclusion: We proposed and evaluated a method to determine the transmittance of the eye in vivo using the double-pass system., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Contribución de congreso (ConferenceOutput)

Multispectral retinography in healthy adult population

  • Burgos Fernández, Francisco Javier
  • Alterini, Tommaso
  • Díaz Douton, Fernando
  • Bou Marín, Marina
  • Vilaseca Ricart, Meritxell
Spectral reflectance of the eye fundus was evaluated in adult healthy patients through a fast visible and near-infrared multispectral fundus camera. Spectral signatures were analyzed for different ocular structures of the retina and the choroid., This project has received funding from the European Union's Horizon 2020 research and innovation programme under Marie Skłodowska-Curie grant agreement No. 801342 (Tecniospring INDUSTRY) and the Government of Catalonia's Agency for Business Competitiveness (ACCIÓ). This research was also supported by the Ministerio de Economía, Industria y Competitividad (MINECO), the Agencia Estatal de Investigación (AEI) and the European Regional Development Fund (FEDER) under the grant DPI2017-89414-R., Peer Reviewed, Postprint (author's final draft)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Membrane protein detection and morphological analysis of red blood cells in hereditary spherocytosis by confocal laser scanning microscopy

  • Rey Barroso, Laura
  • Roldán Molina, Mónica
  • Burgos Fernández, Francisco Javier
  • Isola, Ignacio Mario
  • Ruiz Llobet, Anna
  • Gassiot Riu, Susanna
  • Sarrate Garcia, Edurne
  • Vilaseca Ricart, Meritxell
In hereditary spherocytosis (HS), genetic mutations in the cell membrane and cytoskeleton proteins cause structural defects in red blood cells (RBCs). As a result, cells are rigid and misshapen, usually with a characteristic spherical form (spherocytes), too stiff to circulate through microcirculation regions, so they are prone to undergo hemolysis and phagocytosis by splenic macrophages. Mild to severe anemia arises in HS, and other derived symptoms like splenomegaly, jaundice, and cholelithiasis. Although abnormally shaped RBCs can be identified under conventional light microscopy, HS diagnosis relies on several clinical factors and sometimes on the results of complex molecular testing. It is specially challenging when other causes of anemia coexist or after recent blood transfusions. We propose two different approaches to characterize RBCs in HS: (i) an immunofluorescence assay targeting protein band 3, which is affected in most HS cases and (ii) a three-dimensional morphology assay, with living cells, staining the membrane with fluorescent dyes. Confocal laser scanning microscopy (CLSM) was used to carry out both assays, and in order to complement the latter, a software was developed for the automated detection of spherocytes in blood samples. CLSM allowed the precise and unambiguous assessment of cell shape and protein expression., This publication is part of the project PID2020-112527RBI00, funded by CIN/AEI/10.13039/501100011033. Laura Rey-Barroso thanks the Ministry of Science, Innovation and Universities for the PhD (FPI) grant she has received (DPI2017-89414-R). The current study has been funded by the Spanish National Agency of Investigation (AEI)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Spectroscopic evaluation of red blood cells of thalassemia patients with confocal microscopy: a pilot study

  • Rey Barroso, Laura
  • Roldan, Monica
  • Burgos Fernández, Francisco Javier
  • Gassiot Riu, Susanna
  • Ruiz Llobet, Anna
  • Isola, Ignacio
  • Vilaseca Ricart, Meritxell
Hemoglobinopathies represent the most common single-gene defects in the world and pose a major public health problem, particularly in tropical countries, where they occur with high frequency. Diagnosing hemoglobinopathies can sometimes be difficult due to the coexistence of different causes of anemia, such as thalassemia and iron deficiency, and blood transfusions, among other factors, and requires expensive and complex molecular tests. This work explores the possibility of using spectral confocal microscopy as a diagnostic tool for thalassemia in pediatric patients, a disease caused by mutations in the globin genes that result in changes of the globin chains that form hemoglobin—in pediatric patients. Red blood cells (RBCs) from patients with different syndromes of alpha-thalassemia and iron deficiency (including anemia) as well as healthy (control) subjects were analyzed under a Leica TCS SP8 confocal microscope following different image acquisition protocols. We found that diseased RBCs exhibited autofluorescence when excited at 405 nm and their emission was collected in the spectral range from 425 nm to 790 nm. Three experimental descriptors calculated from the mean emission intensities at 502 nm, 579 nm, 628 nm, and 649 nm allowed us to discriminate between diseased and healthy cells. According to the results obtained, spectral confocal microscopy could serve as a tool in the diagnosis of thalassemia., This research was funded by Spanish Ministry of Economy and Competitiveness, grant number DPI2017-89414-R. L.R.-B. thanks the Ministry of Science, Innovation and Universities for the PhD (FPI) grant she has received., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication

Visible and extended near-infrared multispectral imaging for skin cancer diagnosis

  • Rey Barroso, Laura
  • Burgos Fernández, Francisco Javier
  • Delpueyo, Xana
  • Ares Rodríguez, Miguel
  • Royo Royo, Santiago
  • Malvehy Guilera, Josep
  • Puig, Susana
  • Vilaseca Ricart, Meritxell
With the goal of diagnosing skin cancer in an early and noninvasive way, an extended near infrared multispectral imaging system based on an InGaAs sensor with sensitivity from 995 nm to 1613 nm was built to evaluate deeper skin layers thanks to the higher penetration of photons at these wavelengths. The outcomes of this device were combined with those of a previously developed multispectral system that works in the visible and near infrared range (414 nm–995 nm). Both provide spectral and spatial information from skin lesions. A classification method to discriminate between melanomas and nevi was developed based on the analysis of first-order statistics descriptors, principal component analysis, and support vector machine tools. The system provided a sensitivity of 78.6% and a specificity of 84.6%, the latter one being improved with respect to that offered by silicon sensors., This research was supported by the Spanish Ministry of Economy and Competitiveness under the grant DPI2014-56850-R, DPI2017-89414-R, and by the European Union through the project DIAGNOPTICS ‘diagnosis of skin cancer using optics’ (ICT PSP seventh call for proposals 2013)., Peer Reviewed, Postprint (published version)
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Characteristics of saccades during the near point of convergence test

  • Mestre Ferrer, Clara
  • Bedell, Harold E.
  • Díaz Douton, Fernando
  • Pujol Ramo, Jaume
  • Gautier, Josselyn
The near point of convergence test is widely used to evaluate binocular vision. It assesses the ability of the eyes to converge at short distances. Although the test consists of a pure symmetrical vergence task, small involuntary saccades occur concurrently. The main goal of this study was to analyze saccadic characteristics as a function of vergence demand when testing the near point of convergence. To this purpose, the eye movements of 11 participants were registered with an eye-tracker while they performed the near point of convergence test by following a target that traveled forward and backward on a motorized bench. Saccade amplitude increased and, on average, saccade rate decreased with vergence demand. In general, the direction of the concurrent vergence movement had no significant effect on saccade characteristics. However, each individual subject showed idiosyncratic behavior. Most saccades tended to be corrective in terms of both binocular disparity and individual fixation position errors. In particular, most participants tended to correct the fixation position error of the dominant eye., Peer Reviewed, Postprint (published version)