Skip to main content

ESTUDIO Y DISEÑO DE NUEVOS RECEPTORES SOLARES

ENE2012-34255

•
Funding agency name Ministerio de Economía y Competitividad
Funding agency acronym MINECO
Program Programa Nacional de Proyectos de Investigación Fundamental
Subprogram Subprograma de Proyectos de Investigación Fundamental no Orientada
Call Proyectos I+D
Call year 2012
State Plan 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Management unit Secretaría de Estado de Investigación, Desarrollo e Innovación
Beneficiary centre UNIVERSIDAD CARLOS III DE MADRID

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Thermal design guidelines of solar power towers

  • Rodríguez Sánchez, María de los Reyes
  • Soria Verdugo, Antonio
  • Almendros Ibáñez, José Antonio
  • Acosta Iborra, Antonio
  • Santana Santana, Domingo José
One of the main problems of solar power tower plants with molten salt as heat transfer fluid is the reliability of central receivers. The receiver must withstand high working temperatures, molten salt corrosion and important solar flux transients that lead to thermal stresses and fatigue. Despite these difficulties, it is necessary an estimation of the receiver thermal efficiency in order to have an accurate estimation of the investment cost of the solar plant and to assure the lifetime estimation of the receiver. A thermal, mechanical and hydrodynamic analysis of these receivers has been developing in this work, assuming constant heat flux in each axial discretized section of the tube wall but considering circumferential temperature variations in the perimeter of the tubes caused by the difference between the heat flux received by the front part of the tubes and by the rear part. The thermal analysis shows that the radiation losses are higher than in literature, and consequently the thermal efficiency is lower too. This is due to the fact that the effective tube wall temperature for radiation is higher than the mean tube wall temperature, especially if the rear temperature of the tubes is considered. Besides, it has been found that the highest temperatures and thermal stresses are sited on the eastern and western panels of the receivers. Film temperature is the most limiting parameter for the receiver design due to it is responsible for salt decomposition and tube corrosion. Therefore, once the tube material is chosen, the film temperature cannot exceed a critical value over which the corrosion ratio raises rapidly. Small tube diameters and low number of panels results in low film temperatures, although this kind of design increases the pressure drop. Therefore, a compromise between film temperature and pressure drop can lead to a receiver design that ensures its lifetime, and at the same time, optimizes the investment and operational cost of the receiver., The author would like to thank the financial support from CDTI and S2m Solutions for the project MOSARELA (Molten salt receiver lab) whose reference is IDI-20120128. The financial support of the project ENE2012-34255 is also acknowledged., Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Contribución de congreso (ConferenceOutput)

Medidas experimentales en un lazo de sales fundidas bajo un flujo de calor no uniforme

  • Fernández Torrijos, María
  • Marugán Cruz, Carolina
  • Sobrino Fernández, Celia
  • Santana Santana, Domingo José
En este trabajo se describe una instalación experimental de circulación de sales solaresfundidas para estudiar el proceso de transferencia de calor en receptores de torre externos. Lainstalación experimental está compuesta de un tanque cilíndrico para fundir las sales, unabomba para hacer circular las sales por un tubo y un calentador de inducción para generar elflujo de calor, que se aplica en una pequeña región rectangular de la superficie del tubo. En lasplantas de torre central, se considera que el tubo receptor externo está sometido a radiaciónsolar concentrada unilateral, ya que sólo un lado del tubo recibe un alto flujo de calor. Laprincipal ventaja de usar un calentador de inducción es el control del calentamiento endiferentes áreas del tubo y la capacidad de generar altos flujos de calor. Para estudiar losefectos de un flujo de calor no uniforme sobre la distribución de la temperatura de la pared sehan soldado 15 termopares tipo K en diferentes posiciones azimutales y axiales de la tubería.Se han llevado a cabo diferentes experimentos variando la velocidad de la sal en el lazo paraestudiar su influencia en el proceso de transferencia de calor. Además, se han grabado vídeosde los experimentos con una cámara de infrarrojos, en los que se puede apreciar la deflexióndel tubo a consecuencia del flujo de calor no uniforme aplicado., Los autores agradecen el apoyo financiero del Ministerio de Economía y Competitividad (Proyectos ENE2012-34255 y ENE2014-54942-R) y del Ministerio de Educación, Cultura y Deporte en el marco del programa Formación del Profesorado Universitario (beca FPU/04941)
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Contribución de congreso (ConferenceOutput)

Experimental test of tubular external molten salt receivers under non-steady state conditions

  • Fernández Torrijos, María
  • Marugán Cruz, Carolina
  • Sobrino Fernández, Celia
  • Santana Santana, Domingo José
Proceeding of: SolarPACES 2018: International Conference on Concentrating Solar Power and Chemical Energy Systems, 2-5 October 2018, Casablanca, Morocco, In this work, a molten salt test loop to study the heat transfer under realistic operational conditions of solar power towers is described. The experimental installation is composed of a cylindrical molten salt tank, a pump to circulate the molten salt through a pipe and an induction heater to generate the heat flux, which is applied in a small rectangular region of the outer surface of the pipe. In solar power towers, the receiver tubes are subjected to a unilateral heat flux, because only one side of the pipe receives the solar radiation. The main advantage of using an induction heater to simulate this phenomenon is that a high heat flux can be applied to a delimited region of the external surface of the tube. Experiments where conducted to study the heat transfer process in a pipe circulating nitrate molten salt and subjected to a high and non- uniform heat flux. The temperature of the external wall of the tube was measured at different axial and angular positions varying the molten salt velocity. Besides, the tube bending due to the non-homogenous heat flux was measured using the images taken with an infrared camera. For a molten salt velocity of 0.78m/s, the external wall temperature reached 700 degrees C at the front side of the pipe facing the inductor coil, while a temperature of 420 degrees C was measured at the rear side of the pipe. Additional experiments were done heating the empty tube in absence of molten salt flow, to simulate the start-up heating of the solar receiver. For this experiment, a temperature difference of approximately 340 degrees C is observed between the front and rear side of the pipe, which leads to a higher tube bending than the previous experiments where the molten salt was flowing through the pipe., The authors would like to thank the financial support from Ministry of Economy and Competitiveness (Projects ENE2012-34255 and ENE2014-54942-R) and the Ministry of Education, Culture and Sport under the program of Formación del Profesorado Universitario (FPU14/04941).
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

District cooling network connected to a solar power tower

  • Marugán Cruz, Carolina
  • Sánchez Delgado, Sergio
  • Rodríguez Sánchez, María de los Reyes
  • Venegas Bernal, María Carmen
  • Santana Santana, Domingo José
During the operation of solar power towers there are occasions, commonly in the summer season, where some of the heliostats have to stop focussing on the central receiver, located at the top of the tower, because the maximum thermal power that the receiver can withstand has been reached. The highest cooling demand takes place at these same occasions. In the present paper, the exceeding heliostats are focused to a second receiver, using the extra heat as a source of absorption chillers. The chilled water is used to cool buildings or offices, using a district cooling network, reducing greatly the electricity usage. In this work we have analysed the case of a circular field of heliostats focussing at an external receiver of 120 MW of thermal power. The thermal power of the exceeding heliostats is able to supply steam to eight absorption chillers that produce cold water for a population of more that 90000 people via a network of more than the 50 km. The economical analysis shows that the district cooling system is profitable and an advantageous option for the consumers, that can obtain up to 75% savings on their electricity bills., The authors would like to thank the financial support by the Spanish Ministry of Economy and Competitiveness under Project No. ENE2012-34255 as well as the MOSARELA (Molten salt receiver lab) project, IDI-20120128, supported by CDTI and S2m Solutions., Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Saving assessment using the PERS in solar power towers

  • Rodríguez Sánchez, María de los Reyes
  • Sánchez González, Alberto
  • Marugán Cruz, Carolina
  • Santana Santana, Domingo José
The improvement of the solar power tower using solar salt is one of the main goals of researchers. Any method or invention to improve the efficiency of this technology contributes to promote the renewable energies. The use of a Potential Energy Recovery System (PERS) in two different solar power tower plants of 20 and 100 MW has been analysed. The PERS is formed, at least, by one turbine, located at the hot salt pipe coming from the receiver. The turbine is engaged to the shaft of the feed pump, which raises the heat transfer fluid from the cold tank to the receiver. It reduces the parasitic power consumption of the plant, and increases its global efficiency. Different PERS configurations have been modelled. Based on an energetic and economic analysis, the optimal configuration is a geometrical similar turbine of three times the volume flow rate of one feed pump. The PERS has been proven to be a cost reductive and clean tool. For a 100 MW power plant of 30-year lifetime the investment cost is 1.26 M$ and the annual cash flow is 0.89 M$, while for a plant of 20 MW these values are 0.26 M$ and 0.19 M$, respectively., The financial support from CDTI and S2m Solutions for the MOSARELA Project (Molten salt receiver lab), whose reference is IDI-20120128. Finally, the financial support of the ENE2012-34255 Project is also acknowledged.