e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Thermal design guidelines of solar power towers

  • Rodríguez Sánchez, María de los Reyes
  • Soria Verdugo, Antonio
  • Almendros Ibáñez, José Antonio
  • Acosta Iborra, Antonio
  • Santana Santana, Domingo José
One of the main problems of solar power tower plants with molten salt as heat transfer fluid is the reliability of central receivers. The receiver must withstand high working temperatures, molten salt corrosion and important solar flux transients that lead to thermal stresses and fatigue. Despite these difficulties, it is necessary an estimation of the receiver thermal efficiency in order to have an accurate estimation of the investment cost of the solar plant and to assure the lifetime estimation of the receiver. A thermal, mechanical and hydrodynamic analysis of these receivers has been developing in this work, assuming constant heat flux in each axial discretized section of the tube wall but considering circumferential temperature variations in the perimeter of the tubes caused by the difference between the heat flux received by the front part of the tubes and by the rear part. The thermal analysis shows that the radiation losses are higher than in literature, and consequently the thermal efficiency is lower too. This is due to the fact that the effective tube wall temperature for radiation is higher than the mean tube wall temperature, especially if the rear temperature of the tubes is considered. Besides, it has been found that the highest temperatures and thermal stresses are sited on the eastern and western panels of the receivers. Film temperature is the most limiting parameter for the receiver design due to it is responsible for salt decomposition and tube corrosion. Therefore, once the tube material is chosen, the film temperature cannot exceed a critical value over which the corrosion ratio raises rapidly. Small tube diameters and low number of panels results in low film temperatures, although this kind of design increases the pressure drop. Therefore, a compromise between film temperature and pressure drop can lead to a receiver design that ensures its lifetime, and at the same time, optimizes the investment and operational cost of the receiver., The author would like to thank the financial support from CDTI and S2m Solutions for the project MOSARELA (Molten salt receiver lab) whose reference is IDI-20120128. The financial support of the project ENE2012-34255 is also acknowledged., Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

District cooling network connected to a solar power tower

  • Marugán Cruz, Carolina
  • Sánchez Delgado, Sergio
  • Rodríguez Sánchez, María de los Reyes
  • Venegas Bernal, María Carmen
  • Santana Santana, Domingo José
During the operation of solar power towers there are occasions, commonly in the summer season, where some of the heliostats have to stop focussing on the central receiver, located at the top of the tower, because the maximum thermal power that the receiver can withstand has been reached. The highest cooling demand takes place at these same occasions. In the present paper, the exceeding heliostats are focused to a second receiver, using the extra heat as a source of absorption chillers. The chilled water is used to cool buildings or offices, using a district cooling network, reducing greatly the electricity usage. In this work we have analysed the case of a circular field of heliostats focussing at an external receiver of 120 MW of thermal power. The thermal power of the exceeding heliostats is able to supply steam to eight absorption chillers that produce cold water for a population of more that 90000 people via a network of more than the 50 km. The economical analysis shows that the district cooling system is profitable and an advantageous option for the consumers, that can obtain up to 75% savings on their electricity bills., The authors would like to thank the financial support by the Spanish Ministry of Economy and Competitiveness under Project No. ENE2012-34255 as well as the MOSARELA (Molten salt receiver lab) project, IDI-20120128, supported by CDTI and S2m Solutions., Publicado
e-Archivo. Repositorio Institucional de la Universidad Carlos III de Madrid
Publication Artículo científico (JournalArticle)

Saving assessment using the PERS in solar power towers

  • Rodríguez Sánchez, María de los Reyes
  • Sánchez González, Alberto
  • Marugán Cruz, Carolina
  • Santana Santana, Domingo José
The improvement of the solar power tower using solar salt is one of the main goals of researchers. Any method or invention to improve the efficiency of this technology contributes to promote the renewable energies. The use of a Potential Energy Recovery System (PERS) in two different solar power tower plants of 20 and 100 MW has been analysed. The PERS is formed, at least, by one turbine, located at the hot salt pipe coming from the receiver. The turbine is engaged to the shaft of the feed pump, which raises the heat transfer fluid from the cold tank to the receiver. It reduces the parasitic power consumption of the plant, and increases its global efficiency. Different PERS configurations have been modelled. Based on an energetic and economic analysis, the optimal configuration is a geometrical similar turbine of three times the volume flow rate of one feed pump. The PERS has been proven to be a cost reductive and clean tool. For a 100 MW power plant of 30-year lifetime the investment cost is 1.26 M$ and the annual cash flow is 0.89 M$, while for a plant of 20 MW these values are 0.26 M$ and 0.19 M$, respectively., The financial support from CDTI and S2m Solutions for the MOSARELA Project (Molten salt receiver lab), whose reference is IDI-20120128. Finally, the financial support of the ENE2012-34255 Project is also acknowledged.