Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Tl concentration and its variation in a CsI(Tl) crystal for the CALIFA detector

  • Knyazev, A.
  • Park, J.
  • Golubev, P.
  • Pallon, J.
  • Cederkall, J.
  • Álvarez-Pol, H.
  • Benlliure, J.
  • Briz, José Antonio
  • Cabanelas, P.
  • Casarejos, E.
  • Cortina-Gil, D.
  • Fernández, P.D.
  • Feijoo, M.
  • Galaviz, D.
  • Galiana, E.
  • García Borge, María José
  • Gernhäuser, R.
  • Gonzalez, D.
  • Gutierrez-Neira, C.
  • Hartig, A.L.
  • Heinz, A.
  • Heiss, B.
  • Johansson, H.
  • Klenze, P.
  • Kröll, T.
  • Nilsson, T.
  • Perea, Ángel
  • Ponnath, L.
  • Rhee, H.B.
  • Tengblad, Olof
  • Teubig, P.
9 pags., 6 figs., One of the factors that can contribute to the resolution of long, doped inorganic scintillators used for nuclear spectroscopy is the variation of the dopant concentration over the length the detector crystal. In this work an investigation of such potential variations in one of the CsI(Tl) scintillators used in the calorimeter, CALIFA, of the RB experiment at FAIR, has been performed using particle induced X-ray emission. No statistically significant gradient in doping level was found along the long axis of the investigated sample crystal and the mean value of the Tl concentration was measured to be 0.0839(38)% by weight. This corresponds to a light output of 97.3 % relative to the maximum attainable light output according to previously published work. By taking the ±1σ bounds, the 3% statistical spread in the relative light output provides a good reference value of the minimum light-output non-uniformity observed for the CALIFA crystals. If the relative light output is estimated pointwise from a set of Tl concentration measurements a light-output non-uniformity of 4.6(2.4)% results. For a γ-ray energy of 662 keV the deduced variation in Tl concentration contributes with 0.48(6)% to the typical resolution of 7.74(6)% measured with a collimated source along the crystal main axis. The result is of interest for the characterization of the detector system performance and for realistic simulations of the light collection process in detector systems that are used for nuclear spectroscopy and calorimetry., This work was supported by the Swedish research council (VR) grants 2017-03986, 2014-06644, 2013-04178, 2012-04550, BMBF contracts 05P15WOFNA, 05P19WOFN1, 05P15RDFN1, 05P19RDFN1, the TU Darmstadt – GSI cooperation contract HIC for FAIR, by the Spanish National Research Council, Spain grants FPA02015-64969-P (MINDECO/FEDER/EU), FPA2015-69640-C2-1-P, PGC2018-099746-B-C21, MDM-2016.0692 (MINECO/FEDER/EU) and by GRC, Germany ED431C 2017/54 (Xunta de Galicia/FEDER/EU).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Simulations of light collection in long tapered CsI(Tl) scintillators using real crystal surface data and comparisons to measurement

  • Knyazev, A.
  • Park, J.
  • Golubev, P.
  • Cederkäll, J.
  • Álvarez-Pol, H.
  • Benlliure, J.
  • Cabanelas, P.
  • Casarejos, E.
  • Causeret, L.
  • Cortina-Gil, D.
  • Díaz Fernández, P.
  • Feijoo, M.
  • Galaviz, D.
  • Galiana, E.
  • Gernhäuser, R.
  • González, D.
  • Hartig, A.L.
  • Heinz, A.
  • Heiss, B.
  • Johansson, H.T.
  • Klenze, P.
  • Kröll, T.
  • Perea, Ángel
  • Ponnath, L.
  • Ren, Z.
  • Rhee, H.B.
  • Rodríguez-Sánchez, J.L.
  • Rondeau, G.
  • Tengblad, Olof
  • Scheblykin, I.G.
  • Teubig, P.
  • Timm, R.
10 pags., 9 figs., 2 tabs., Simulation results for light transport in long tapered CsI(Tl) crystals using look-up tables (LUTs) are presented. The LUTs were derived from the topography of a polished and a lapped surface of a CsI(Tl) crystal measured with atomic force microscopy. Simulations with different combinations of polished and lapped surfaces were performed, to extract the non-uniformity of light collection depending on the interaction point, and compared to experimental results. The simulations reproduce the general trend given by the measurements, and show that more homogeneous light collection is attained when all lateral sides of the crystal are lapped. For the lapped crystal the simulation model is most sensitive to the reflectivity of the enhanced specular reflector (ESR) foil surrounding the crystal, which is one of several properties influencing the light transport examined in this study. The sensitivity of the light-output non-uniformity to variations in the absorption length observed in a batch of CsI(Tl) crystals in a previous study is also discussed. Residual differences between the simulation and the measurements can potentially be attributed to the scattering of scintillation photons inside the materials used. Additional measurements to further advance the construction of the simulation model are suggested., This work was supported by the Swedish research council (VR) grants 2017-03986, 2014-06644, 2013-04178, 2012-04550, BMBF contracts 05P15WOFNA, 05P19WOFN1, 05P15RDFN1, 05P19RDFN1, the TU Darmstadt – GSI cooperation contract HIC for FAIR, by the Spanish research council grants FPA02015-64969-P (MINDECO/FEDER/EU), FPA2015-69640-C2-1-P, PGC2018-099746-B-C21, MDM-2016.0692 (MINECO/FEDER/EU) and by ED431C-2017/54 and EDB481-2017/002 (Xunta de Galicia/FEDER/EU)., Peer reviewed