Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 37
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The Event Detection System in the NEXT-White Detector

  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Simón Estévez, Ander
  • Monrabal Capilla, Francesc
  • Rodriguez-Samaniego, Javier
  • Querol-Segura, Marc
[EN] This article describes the event detection system of the NEXT-White detector, a 5 kg high pressure xenon TPC with electroluminescent amplification, located in the Laboratorio Subterráneo de Canfranc (LSC), Spain. The detector is based on a plane of photomultipliers (PMTs) for energy measurements and a silicon photomultiplier (SiPM) tracking plane for offline topological event filtering. The event detection system, based on the SRS-ATCA data acquisition system developed in the framework of the CERN RD51 collaboration, has been designed to detect multiple events based on online PMT signal energy measurements and a coincidence-detection algorithm. Implemented on FPGA, the system has been successfully running and evolving during NEXT-White operation. The event detection system brings some relevant and new functionalities in the field. A distributed double event processor has been implemented to detect simultaneously two different types of events thus allowing simultaneous calibration and physics runs. This special feature provides constant monitoring of the detector conditions, being especially relevant to the lifetime and geometrical map computations which are needed to correct high-energy physics events. Other features, like primary scintillation event rejection, or a double buffer associated with the type of event being searched, help reduce the unnecessary data throughput thus minimizing dead time and improving trigger efficiency., The NEXT collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT, the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FISNUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The electronics of the energy plane of the NEXT-White detector

  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Laing, A.
  • Rodriguez-Samaniego, Javier
  • Querol-Segura, Marc
  • Monrabal, Francesc
  • Gómez-Cadenas, J.J.
[EN] This paper describes the electronics of NEXT-White (NEW) detector PMT plane, a high pressure xenon TPC with electroluminescent amplification (HPXe-EL) currently operating at the Laboratorio Subterraneo de Canfranc (LSC) in Huesca, Spain. In NEXT-White the energy of the event is measured by a plane of photomultipliers (PMTs) located behind a transparent cathode. The PMTs are Hamamatsu R11410-10 chosen due to their low radioactivity. The electronics have been designed and implemented to fulfill strict requirements: an overall energy resolution below 1% and a radiopurity budget of 20 mBq unit(-1) in the chain of Bi-214. All the components and materials have been carefully screened to assure a low radioactivity level and at the same time meet the required front-end electronics specifications. In order to reduce low frequency noise effects and enhance detector safety a grounded cathode connection has been used for the PMTs. This implies an AC-coupled readout and baseline variations in the PMT signals. A detailed description of the electronics and a novel approach based on a digital baseline restoration to obtain a linear response and handle AC coupling effects is presented. The final PMT channel design has been characterized with linearity better than 0.4% and noise below 0.4mV., We acknowledge support from the following agencies and institutions: the European Research Council (ERC), Spain under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program, Spain SEV-2014-0398 and the Maria de Maetzu Program, Spain MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT and FEDER, Spain through the program COMPETE, projects PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and de-sc0017721 (University of Texas at Arlington); and the University of Texas at Arlington. We acknowledge partial support from the European Union Horizon 2020 research and innovation programme, Spain under the Marie Sklodowska-Curie grant agreements No. 690575 and 674896. We also warmly acknowledge the Laboratorio Nazionale di Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Mitigation of backgrounds from cosmogenic Xe-137 in xenon gas experiments using He-3 neutron capture

  • Rogers, L.
  • Jones, B. J. P.
  • Laing, A.
  • Pingulkar, S.
  • Smithers, B.
  • Woodruff, K.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I. J.
  • Azevedo, C. D. R.
  • Bailey, K.
  • Benlloch-Rodríguez, J. M.
  • Borges, F. I. G. M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Xe-136 is used as the target medium for many experiments searching for 0 nu beta beta. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of Xe-137 created by the capture of neutrons on Xe-136. This isotope decays via beta decay with a half-life of 3.8 min and a Q(beta) of similar to 4.16 MeV. This work proposes and explores the concept of adding a small percentage of He-3 to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from Xe-137 activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory., The work described was supported by the Department of Energy under Award numbers DE-SC0019054 and DE-SC0019223. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Program for Research and Innovation Horizon 2020 (2014-2020) under the Marie Skodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Demonstration of background rejection using deep convolutional neural networks in the NEXT experiment

  • Kekic, M.
  • Adams, C.
  • Woodruff, K.
  • Renner, J.
  • Church, E.
  • Del Tutto, M.
  • Hernando Morata, J. A.
  • Gomez-Cadenas, J. J.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C. D. R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Convolutional neural networks (CNNs) are widely used state-of-the-art computer vision tools that are becoming increasingly popular in high-energy physics. In this paper, we attempt to understand the potential of CNNs for event classification in the NEXT experiment, which will search for neutrinoless double-beta decay in Xe-136. To do so, we demonstrate the usage of CNNs for the identification of electron-positron pair production events, which exhibit a topology similar to that of a neutrinoless double-beta decay event. These events were produced in the NEXT-White high-pressure xenon TPC using 2.6 MeV gamma rays from a Th-228 calibration source. We train a network on Monte Carlo-simulated events and show that, by applying on-the-fly data augmentation, the network can be made robust against differences between simulation and data. The use of CNNs offers significant improvement in signal efficiency and background rejection when compared to previous non-CNN-based analyses, This study used computing resources from Artemisa, co-funded by the European Union through the 2014-2020 FEDER Operative Programme of the Comunitat Valenciana, project DIFEDER/2018/048. This research used resources of the Argonne Leadership Computing Facility, which is a DOE Office of Science User Facility supported under Contract DE-AC02-06CH11357. The NEXT collaboration acknowledges support from the following agencies and institutions: Xunta de Galicia (Centro singularde investigacion de Galicia accreditation 2019-2022), by European Union ERDF, and by the "Maria de Maeztu" Units of Excellence program MDM-2016-0692 and the Spanish Research State Agency"; the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-20140398 and CEX2018-000867-S; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015 18820. JMA acknowledges support from Fundacion Bancaria "la Caixa" (ID 100010434), grant code LCF/BQ/PI19/11690012. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Data Compression in the NEXT-100 Data Acquisition System

  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Rodríguez Ponce, Jorge
  • Simón Estévez, Ander
  • Benlloch Rodríguez, José María
[EN] NEXT collaboration detectors are based on energy measured by an array of photomultipliers (PMT) and topological event filtering based on an array of silicon photomultipliers (SiPMs). The readout of the PMT sensors for low-frequency noise effects and detector safety issues requires a grounded cathode connection that makes the readout AC-couple with variations in the signal baseline. Strict detector requirements of energy resolution better than 1% FWHM require a precise baseline reconstruction that is performed offline for data analysis and detector performance characterization. Baseline variations make it inefficient to apply traditional lossy data compression techniques, such as zero-suppression, that help to minimize data throughput and, therefore, the dead time of the system. However, for the readout of the SiPM sensors with less demanding requirements in terms of accuracy, a traditional zero-suppression is currently applied with a configuration that allows for a compression ratio of around 71%. The third stage in the NEXT detectors program, the NEXT-100 detector, is a 100 kg detector that instruments approximately five times more PMT sensors and twice the number of SiPM sensors than its predecessor, the NEXT-White detector, putting more pressure in the DAQ throughput, expected to be over 900 MB/s with the current configuration, which will worsen the dead time of the acquisition data system. This paper describes the data compression techniques applied to the sensor data in the NEXT-100 detector, which reduces data throughput and minimizes dead time while maintaining the event rate to the level of its predecessor, around 50 Hz., NEXT collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Research Council (ERC) under Grant Agreement No. 101039048-GanESS; the European Union's Framework Program for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 957202-HIDDEN; the MCIN/AEI/10.13039/501100011033 of Spain and ERDF A way of making Europe under grant RTI2018-095979, the Severo Ochoa Program grant CEX2018-000867-S and the Maria de Maeztu Program grant MDM-2016-0692; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087 and CIDEGENT/2019/049; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under grants 877040 and 877041; the US Department of Energy under contract number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401. A.S.E acknowledges support from the Kreitman School of Advanced Graduate Studies at Ben-Gurion University and from the Marie Sklodowska-Curie grant agreement No. 101026628. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

PADC nuclear track detector for ion spectroscopy in laser-plasma acceleration

  • Seimetz, Michael
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Peñas, J.
  • Llerena, J. J.
  • Benlliure, J.
  • García López, J.
  • Millán-Callado, M. A.
[EN] The transparent polymer polyallyl-diglycol-carbonate (PADC), also known as CR-39, is widely used as detector for heavy charged particles at low fluence. It allows for detection of single protons and ions via formation of microscopic tracks after etching in NaOH or KOH solutions. PADC combines a high sensitivity and high specificity with inertness towards electromagnetic noise. Present fields of application include laser-ion acceleration, inertial confinement fusion, radiobiological studies with cell cultures, and dosimetry of nuclear fragments in particle therapy. These require precise knowledge of the energy-dependent response of PADC to different ion species. We present calibration data for a new type of detector material, Radosys RS39, to protons (0.2-3 MeV) and carbon ions (0.6-12 MeV). RS39 is less sensitive to protons than other types of PADC. Its response to carbon ions, however, is similar to other materials. Our data indicate that RS39 allows for measuring carbon ion energies up to 10 MeV only from the track diameters. In addition, it can be used for discrimination between protons and carbon ions in a single etching process., Project funded by CSIC, Grant No. 2018501082, and by the Spanish Ministerio de Ciencia, Innovacion y Universidades, project MdM-2016-0692-17-2 via a predoctoral grant of type Maria de Maeztu FPI. Nuclear track detector material and readout equipment have been provided by Radosys Ldt. (Budapest). The authors acknowledge the contributions and commitment of the CNA accelerator operators. MS would like to thank L. Ballesteros and J. Ortiz for their support with precision equipment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Search for Spatial Correlations of Neutrinos with Ultra-high-energy Cosmic Rays

  • Albert, A.
  • Alves, S.
  • Andre, M.
  • Anghinolfi, M.
  • Aubert,, J.J.
  • Aublin, J.
  • Baret, B.
  • Basa, S.
  • Belhorma, B.
  • Bendahman, M.
  • Bertin, V.
  • Biagi, S.
  • M. Bissinger
  • Martínez Mora, Juan Antonio
  • Poirè, Chiara
  • Ardid, Miguel|||0000-0002-3199-594X
  • Ardid, S.|||0000-0003-4821-6655
[EN] For several decades, the origin of ultra-high-energy cosmic rays (UHECRs) has been an unsolved question of high- energy astrophysics. One approach for solving this puzzle is to correlate UHECRs with high-energy neutrinos, since neutrinos are a direct probe of hadronic interactions of cosmic rays and are not de¿ected by magnetic ¿elds. In this paper, we present three different approaches for correlating the arrival directions of neutrinos with the arrival directions of UHECRs. The neutrino data are provided by the IceCube Neutrino Observatory and ANTARES, while the UHECR data with energies above ~50 EeV are provided by the Pierre Auger Observatory and the Telescope Array. All experiments provide increased statistics and improved reconstructions with respect to our previous results reported in 2015. The ¿rst analysis uses a high-statistics neutrino sample optimized for point- source searches to search for excesses of neutrino clustering in the vicinity of UHECR directions. The second analysis searches for an excess of UHECRs in the direction of the highest-energy neutrinos. The third analysis searches for an excess of pairs of UHECRs and highest-energy neutrinos on different angular scales. None of the analyses have found a signi¿cant excess, and previously reported over¿uctuations are reduced in signi¿cance. Based on these results, we further constrain the neutrino ¿ux spatially correlated with UHECRs., The authors of the ANTARES collaboration acknowledge the financial support of the funding agencies: Centre National de la Recherche Scientifique (CNRS), Commissariat a l'energie atomique et aux energies alternatives (CEA), Commission Europeenne (FEDER fund and Marie Curie Program), Institut Universitaire de France (IUF), LabEx UnivEarthS (ANR-10-LABX-0023 and ANR-18-IDEX-0001), Region Ile-de-France (DIM-ACAV), Region Alsace (contrat CPER), Region Provence-Alpes-Cote d'Azur, Departement du Var and Ville de La Seyne-sur-Mer, France; Bundesministerium fur Bildung und Forschung (BMBF), Germany; Istituto Nazionale di Fisica Nucleare (INFN), Italy; Nederlandse organisatie voor Wetenschappelijk Onderzoek (NWO), the Netherlands; Council of the President of the Russian Federation for young scientists and leading scientific schools supporting grants, Russia; Executive Unit for Financing Higher Education, Research, Development and Innovation (UEFISCDI), Romania; Ministerio de Ciencia, Innovacion, Investigacion y Universidades (MCIU): Programa Estatal de Generacion de Conocimiento (refs. PGC2018-096663-B-C41, -A-C42, -B-C43, -B-C44) (MCIU/FEDER), Generalitat Valenciana: Prometeo (PROMETEO/2020/019), Grisolia (refs. GRISOLIA/2018/119,/2021/192) and GenT (refs. CIDEGENT/2018/034,/2019/043,/2020/049,/2021/023) programs, Junta de Andalucia (ref. A-FQM-053-UGR18), La Caixa Foundation (ref. LCF/BQ/IN17/11620019), EU: MSC program (ref. 101025085), Spain; Ministry of Higher Education, Scientific Research and Innovation, Morocco, and the Arab Fund for Economic and Social Development, Kuwait. We also acknowledge the technical support of Ifremer, AIM and Foselev Marine for the sea operation and the CC-IN2P3 for the computing facilities. The ANTARES collaboration acknowledges the significant contributions to this manuscript from Julien Aublin.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electron drift properties in high pressure gaseous xenon

  • Simon, A.
  • Felkai, R.
  • Martinez-Lema, G.
  • Monrabal, F.
  • Gonzalez-Diaz, D.
  • Sorel, M.
  • Hernando Morata, J. A.
  • Gomez-Cadenas, J. J.
  • Adams, C.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and di¿usion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent ampli¿cation, a 1:2 scale model of the future NEXT-100detector, which will be dedicated to neutrinoless double beta decay searches. NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since December2016. The drift parameters have been measured using 83mKr for a range of reduced drift ¿elds at two di¿erent pressure regimes, namely 7.2 bar and 9.1 bar. Theresults have been compared with Magboltz simulations. Agreement at the 5% level or better has been found for drift velocity, longitudinal di¿usion and transverse di¿usion., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT and FEDER through the program COMPETE, projects PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and de-sc0017721 (University of Texas at Arlington); and the University of Texas at Arlington. We also warmly acknowledge the Laboratorio Nazionale di Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The Next White (NEW) detector

  • Monrabal, F.
  • Gomez-Cadenas, J. J.
  • Laing, A.
  • Benlloch-Rodriguez, J. M.
  • Carcel, S.
  • Carrion, J
  • Felkai, R.
  • Martinez, A.
  • Musti, M.
  • Ouero, M.
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
[EN] Conceived to host 5 kg of xenón at a pressure of 15 bar in the ¿ducial volume,the NEXTWhite (NEW)apparatus is currently the largest high pressure xenon gas TPC using electroluminescent ampli¿cation in the world. It is also a 1:2 scale model of the NEXT-100 detector scheduled to start searching for ßß0¿ decays in 136Xe in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2017 at the Canfranc Underground Laboratory (LSC), in Spain. This paper describes the detector and associated infrastructures., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT and FEDER through the program COMPETE, projects PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contract numbers DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0017721 (University of Texas at Arlington), and DE-AC02-06CH11357 (Argonne National Laboratory); and the University of Texas at Arlington. We also warmly acknowledge the Laboratorio Nazionale di Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electroluminescence TPCs at the thermal diffusion limit

  • Henriques, C. A. O.
  • Monteiro, C. M. B.
  • Gonzalez-Diaz, D.
  • Azevedo, C. D. R.
  • Freitas, E. D. C.
  • Mano, R. D. P.
  • Jorge, M. R.
  • Fernandes, A. F. M.
  • Gomez-Cadenas, J. J.
  • Fernandes, L. M. P.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the 136Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO2, CH4 and CF4) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/ sqrt(¿) for pure xenon down to 2.5 mm/sqrt(m) using additive concentrations of about 0.05%, 0.2% and 0.02% for CO2, CH4 and CF4, respectively. Our results show that CF4 admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH4 presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO2 and CH4 show potential as molecular additives in a large xenon TPC. While CO2 has some operational constraints, making it difficult to be used in a large TPC, CH4 shows the best performance and stability as molecular additive to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%, which is only slightly worse than the one obtained for pure xenon. We demonstrate the possibility to have an electroluminescence TPC operating very close to the thermal diffusion limit without jeopardizing the TPC performance, if CO2 or CH4 are chosen as additives., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-AC02-06CH11357 (Argonne National Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0017721 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air

  • Ghosh, S.
  • Haefner, J.
  • Martín-Albo, J.
  • Guenette, R.
  • Li, X.
  • Loya Villalpando, A.A.
  • Burch, C.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Benlloch-Rodríguez, J.M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm We also see that the reflectance of PIFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance in the visible without introducing a specular component in the reflectance., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the Maria de Maeztu Program MDM-2016-0692; the Generalitat Valenciana under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/04559/2020 to fund the activities of LIBPhys-UC; the U.S. Department of Energy under contracts No. DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC0207CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington (USA). DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC2015-18820. JM-A acknowledges support from Fundacion Bancaria "la Caixa" (ID 100010434), grant code LCF/BQ/PI19/11690012. Finally, we thank Brendon Bullard, Paolo Giromini and Neeraj Tata for helpful discussions and assistance with preliminary measurements.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Demonstration of the event identification capabilities of the NEXT-White detector

  • Ferrario, Paola
  • Benlloch-Rodríguez, J.M.
  • Díaz López, G.
  • Hernando Morata, J.A.
  • Kekic, M.
  • Renner, J.
  • Usón, A.
  • Gómez-Cadenas, J.J.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a 228Th calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of 71.6 ± 1.5 stat ± 0.3 sys% for a background acceptance of 20.6 ± 0.4 stat ± 0.3 sys% is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/FBD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental Setup for Irradiation of Cell Cultures at L2A2

  • Torralba, Alberto
  • Palenciano-Castro, Lidia
  • Reija, Alicia
  • Rigla, Juan Pablo
  • Peñas, Juan
  • Llerena, Juan José
  • Contreras-Martinez, Ramiro
  • Benlliure, José
  • Vega, Ana
  • Aguado-Barrera, Miguel Elías
  • Ruiz, Camilo
  • Seimetz, Michael
[EN] Laser-plasma proton sources and their applications to preclinical research has become a very active field of research in recent years. In addition to their small dimensions as compared to classical ion accelerators, they offer the possibility to study the biological effects of ultra-short particle bunches and the correspondingly high dose rates. We report on the design of an experimental setup for the irradiation of cell cultures at the L2A2 laboratory at the University of Santiago de Compostela, making use of a 1.2 J Ti: Sapphire laser with a 10 Hz repetition rate. Our setup comprises a proton energy separator consisting of two antiparallel magnetic fields realized by a set of permanent magnets. It allows for selecting a narrow energy window around an adaptable design value of 5 MeV out of the initially broad spectrum typical for Target Normal Sheath Acceleration (TNSA). At the same time, unwanted electrons and X-rays are segregated from the protons. This part of the setup is located inside the target vessel of the L2A2 laser. A subsequent vacuum flange sealed with a thin kapton window allows for particle passage to external sample irradiation. A combination of passive detector materials and real-time monitors is applied for measurement of the deposited radiation dose. A critical point of this interdisciplinary project is the manipulation of biological samples under well-controlled, sterile conditions. Cell cultures are prepared in sealed flasks with an ultra-thin entrance window and analysed at the nearby Fundacion Publica Galega Medicina Xenomica and IDIS. The first trials will be centred at the quantification of DNA double-strand breaks as a function of radiation dose., Projects RTI2018-101578-B-C21 and RTI2018-101578-B-C22 are funded by MCIN/AEI /10.13039/501100011033 and by FEDER "Una manera de hacer Europa". Project AICO/2020/207 is funded by Generalitat Valenciana. Supports PEJ2018-002035-A and PEJ2018-002037-A are financed by AEI and "El FSE invierte en tu futuro". Additional funding is by FPI predoctoral grant BES-2017-08917 and Unidad de Excelencia Maria de Maeztu, MdM-2016-0692-17-2. Action is co-financed by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER) of the Comunitat Valenciana 2014-2020 (IDIFEDER/2018/022 and IDIFEDER/2021/004). FPGMX-IDIS research is partially supported by the Spanish Instituto de Salud Carlos III (ISCIII) funding, which is an initiative of the Spanish Ministry of Economy and Innovation partially supported by European Regional Development FEDER Funds (INT20/00071, PI19/01424, AC18/00117) and through the Autonomous Government of Galicia (Consolidation and structuring program: IN607B) given to A. Vega.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Sensitivity of the NEXT experiment to 124-Xe double electron capture

  • Martinez-Lema, G.
  • Martinez-Vara, M.
  • Sorel, M.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C. D. R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Borges, F. I. G. M.
  • Byrnes, N.
  • Carcel, S.
  • Carrión, J. V.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite di erent, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture has been predicted for a number of isotopes, but only observed in 78Kr, 130Ba and, recently, 124Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process. Here we report on the current sensitivity of the NEXT-White detector to 124Xe 2 ECEC and on the extrapolation to NEXT-100. Using simulated data for the 2 ECEC signal and real data from NEXT-White operated with 124Xe-depleted gas as background, we de ne an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124Xe and for a 5-year run, a sensitivity to the two-neutroni double electron capture half-life of 6x10exp22 years (at 90% con dence level) or better can be reached., The NEXT collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the Maria de Maeztu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

  • Fernandes, A.F.M.
  • Henriques, C.A.O.
  • Mano, R.D.P.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Silva, P.A.O.C.
  • Gómez-Cadenas, J.J.
  • Freitas, E.D.C.
  • Fernandes, L.M.P.
  • Monteiro, C.M.B.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Bailey, K.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the EL region, the EL yield is lowered by similar to 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economa y Competitividad of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Mara de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015; the U.S. Department of Energy under contracts number DEAC02-06CH11357 (Argonne National Laboratory), DE-AC0207CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A& M) and DE-SC0019223/DESC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Sensitivity of a tonne-scale NEXT detector for neutrinoless double-beta decay searches

  • Adams, C.
  • Alvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Borges, F. I. G. M.
  • Byrnes, N.
  • Carcel, S.
  • Carrión, J.V.
  • Cebrian, S.
  • Church, E.
  • Conde, C. A. N.
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta (0 nu beta beta) decay of Xe-136 using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of 0 nu beta beta decay better than 10(27) years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the inverted ordering of neutrino masses, and beyond., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the Maria de Maeztu Program MDM2016-0692; the Generalitat Valenciana of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under grants 877040 and 877041; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC0207CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges support from the Ramon y Cajal program (Spain) under contract number RYC-2015-18820. JM-A acknowledges support from Fundacion Bancaria la Caixa (ID 100010434), grant code LCF/BQ/PI19/11690012, and from the Plan GenT program of the Generalitat Valenciana, grant code CIDEGENT/2019/049. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Neutral Bremsstrahlung Emission in Xenon Unveiled

  • Henriques, C.A.O.
  • Amedo, P.
  • Teixeira, J. M. R.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Para, A.
  • Martín-Albo,J.
  • Saa Hernandez, A.
  • Gómez-Cadenas, J. J.
  • Nygren, D. R.
  • Monteiro, C.M.B.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Lopez-March, N.
  • Rodríguez, J.
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] We present evidence of non-excimer-based secondary scintillation in gaseous xenon, obtained using both the NEXT-White time projection chamber (TPC) and a dedicated setup. Detailed comparison with first-principle calculations allows us to assign this scintillation mechanism to neutral bremsstrahlung (NBrS), a process that is postulated to exist in xenon that has been largely overlooked., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Advanced Grant No. 339787-NEXT; the European Unions Framework Program for Research and Innovation Horizon 2020 (20142020) under Grant Agreements No. 674896, No. 690575, and No. 740055; the Ministerio de Economa y Competitividad and the Ministerio de Ciencia, Innovacin y Universidades of Spain under Grants No. FIS2014-53371-C04 and No. RTI2018-095979, the Severo Ochoa Program Grants No. SEV-2014-0398 and No. CEX2018-000867-S, and the Mara de Maeztu Program MDM-2016-0692; the Generalitat Valenciana under Grants No. PROMETEO/2016/120 and No. SEJI/2017/011; the Portuguese FCT under Project No. PTDC/FIS-NUC/3933/2021 and under Project No. UIDP/04559/2020 to fund the activities of LIBPhys-UC; the U.S. Department of Energy under Contracts No. DE-AC02-06CH11357 (Argonne National Laboratory), No. DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), No. DE-FG02-13ER42020 (Texas A&M), and No. DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington (USA). D. G.-D. acknowledges Ramon y Cajal program (Spain) under Contract No. RYC- 2015-18820. J. M.-A. acknowledges support from Fundacin Bancaria la Caixa (ID 100010434), Grant No. LCF/BQ/PI19/11690012. We would like to thank Lorenzo Muniz for insightful discussions on the subtleties of electron transport in gases.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Radiogenic backgrounds in the NEXT double beta decay experiment

  • Novella, P.
  • Palmeiro, B.
  • Sorel, M.
  • Usón, A.
  • Ferrario, P.
  • Gómez-Cadenas, J. J.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Benlloch-Rodríguez, J. M.
  • Borges, F. I. G. M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity- induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterraneo de Canfranc with xenon depleted in Xe-136 are analyzed to derive a total background rate of (0.84 +/- 0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEXT collaboration. A spectral fit to this model yields the specific contributions of Co-60, K-40, Bi-214 and Tl-208 to the total background rate, as well as their location in the detector volumes. The results are used to evaluate the impact of the radiogenic backgrounds in the double beta decay analyses, after the application of topological cuts that reduce the total rate to (0.25 +/- 0.01) mHz. Based on the best-fit background model, the NEXT-White median sensitivity to the two-neutrino double beta decay is found to be 3.5 sigma after 1 year of data taking. The background measurement in a Q(beta beta)+/- 100 keV energy window validates the best-fit background model also for the neutrinoless double beta decay search with NEXT-100. Only one event is found, while the model expectation is (0.75 +/- 0.12) events., The NEXT collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Measurement of the Xe 136 two-neutrino double -decay half-life via direct background subtraction in NEXT

  • Novella, P.
  • Sorel, M.
  • Usón, A.
  • Adams, C.
  • Almazán, H.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I.J.
  • Ayet, S.
  • Azevedo, D.C.R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Lopez-March, N.
  • Rodríguez, J.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] We report a measurement of the half-life of the 136Xe two-neutrino double-ß decay performed with a novel direct-background-subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with 136Xe-enriched and 136Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of 2.34+0.80(stat)+0.30(sys)×1021 yr is derived from ¿0.46 ¿0.17 the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double-ß-decay searches., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant No. 951281-BOLD; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant No. 957202-HIDDEN; the MCIN/AEI/10.13039/501100011033 of Spain and ERDF "A way of making Europe" under Grant No. RTI2018-095979, the Severo Ochoa Program Grant No. CEX2018-000867-S, and the Maria de Maeztu Program Grant No. MDM-2016-0692; the Generalitat Valenciana of Spain under Grants No. PROMETEO/2021/087 and No. CIDEGENT/2019/049; the Portuguese FCT under Project No. UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under Grants No. 877040 and No. 877041; the U.S. Department of Energy under Contracts No. DE-AC02-06CH11357 (Argonne National Laboratory), No. DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), No. DE-FG02-13ER42020 (Texas A&M), No. DE-SC0019054 (Texas Arlington), and No. DE-SC0019223 (Arlington, TX); the U.S. National Science Foundation under Grant No. CHE 2004111; and the Robert A. Welch Foundation under Grant No. Y-203120200401. D.G.D. acknowledges support from the Ramon y Cajal program (Spain) under Contract No. RYC-2015-18820. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Production of carbon-11 for PET preclinical imaging using a high-repetition rate laser-driven proton source

  • Peñas, Juan
  • Alejo, Aaron
  • Bembibre, Adrian
  • Apiñaniz, Jon Imanol
  • García-García, Enrique
  • Guerrero, Carlos
  • Henares, José Luis
  • Hernández-Palmero, Irene
  • Méndez, Cruz
  • Millán-Callado, María Ángeles
  • Puyuelo-Valdés, Pilar
  • Benlliure, José
  • Seimetz, Michael
[EN] Most advanced medical imaging techniques, such as positron-emission tomography (PET), require tracers that are produced in conventional particle accelerators. This paper focuses on the evaluation of a potential alternative technology based on laser-driven ion acceleration for the production of radioisotopes for PET imaging. We report for the frst time the use of a high-repetition rate, ultraintense laser system for the production of carbon-11 in multi-shot operation. Proton bunches with energies up to 10¿14 MeV were systematically accelerated in long series at pulse rates between 0.1 and 1 Hz using a PW-class laser. These protons were used to activate a boron target via the 11B(p,n)11C nuclear reaction. A peak activity of 234 kBq was obtained in multi-shot operation with laser pulses with an energy of 25 J. Signifcant carbon-11 production was also achieved for lower pulse energies. The experimental carbon-11 activities measured in this work are comparable to the levels required for preclinical PET, which would be feasible by operating at the repetition rate of current state-of-theart technology (10 Hz). The scalability of next-generation laser-driven accelerators in terms of this parameter for sustained operation over time could increase these overall levels into the clinical PET range., This work has received financial support by the Maria de Maetzu Units of Excellence program MDM-2016-0692-17-2, and by the Spanish Ministerio de Ciencia, Innovacion y Universidades under RTI2018-098117-B-C21, RTI2018-101578-B-C21, RTI2018-101578-B-C22, and FPI predoctoral BES-2017-08917 grants, and the Xunta de Galicia grants GRC ED431C 2017/54 and ED431F2023/21. It also was supported by Generalitat Valenciana, grant AICO/2020/207. Action co-financied by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER). This work was supported by 'la Caixa' Foundation (ID 100010434) [fellowship code LCF/BQ/PI20/11760027], and grant RYC2021-032654-I funded by MCIN, AEI and by 'European Union NextGenerationEU'.
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

On the determination of the interaction time of GeV neutrinos in large argon gas TPCs

  • Saá Hernández, A.
  • González Díaz, D.
  • Martín Albo, J.
  • Tuzi, M.
  • Amedo, P.
  • González Baldonedo, Jacobo
  • Benítez, C.
  • Bounasser, S.
  • Casarejos Ruiz, Enrique
  • Collazo Rodriguez, Joaquin Baltasar
  • Fernández Prieto, A.
  • Fernández Posada, D.J.
  • Hafeji, R.
  • Leardini, S.
  • Rodas Rodríguez, D.
  • Saborido, A. L.
  • Segade Robleda, Abraham
  • Slater, A.
Next-generation megawatt-scale neutrino beams open the way to studying neutrino-nucleus scattering using gaseous targets for the first time. This represents an opportunity to improve the knowledge of neutrino cross sections in the energy region between hundreds of MeV and a few GeV, of interest for the upcoming generation of long-baseline neutrino oscillation experiments. The challenge is to accurately track and (especially) time the particles produced in neutrino interactions in large and seamless volumes down to few-MeV energies. We propose to accomplish this through an optically-read time projection chamber (TPC) filled with high-pressure argon and equipped with both tracking and timing functions. In this work, we present a detailed study of the time-tagging capabilities of such a device, based on end-to-end optical simulations that include the effect of photon propagation, photosensor response, dark count rate and pulse reconstruction. We show that the neutrino interaction time can be reconstructed from the primary scintillation signal with a precision in the range of 1–2.5 ns $$(\sigma )$$(σ) for point-like deposits with energies down to 5 MeV. A similar response is observed for minimum-ionizing particle tracks extending over lengths of a few meters. A discussion on previous limitations towards such a detection technology, and how they can be realistically overcome in the near future thanks to recent developments in the field, is presented. The performance demonstrated in our analysis seems to be well within reach of next-generation neutrino-oscillation experiments, through the instrumentation of the proposed TPC with conventional reflective materials and a silicon photomultiplier array behind a transparent cathode., Xunta de Galicia, Generalitat Valenciana | Ref. CIDEGENT/2019/049, Ministerio de Economía y Competitividad | Ref. RYC-2015-18820, Agencia Estatal de Investigación | Ref. RYC2021-033265-I, Ministerio de Economía, Industria y Competitividad | Ref. MDM-2016-0692, Agencia Estatal de Investigación | Ref. PID2021-125028OB-C21
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Tl concentration and its variation in a CsI(Tl) crystal for the CALIFA detector

  • Knyazev, A.
  • Park, J.
  • Golubev, P.
  • Pallon, J.
  • Cederkall, J.
  • Álvarez-Pol, H.
  • Benlliure, J.
  • Briz, José Antonio
  • Cabanelas, P.
  • Casarejos, E.
  • Cortina-Gil, D.
  • Fernández, P.D.
  • Feijoo, M.
  • Galaviz, D.
  • Galiana, E.
  • García Borge, María José
  • Gernhäuser, R.
  • Gonzalez, D.
  • Gutierrez-Neira, C.
  • Hartig, A.L.
  • Heinz, A.
  • Heiss, B.
  • Johansson, H.
  • Klenze, P.
  • Kröll, T.
  • Nilsson, T.
  • Perea, Ángel
  • Ponnath, L.
  • Rhee, H.B.
  • Tengblad, Olof
  • Teubig, P.
9 pags., 6 figs., One of the factors that can contribute to the resolution of long, doped inorganic scintillators used for nuclear spectroscopy is the variation of the dopant concentration over the length the detector crystal. In this work an investigation of such potential variations in one of the CsI(Tl) scintillators used in the calorimeter, CALIFA, of the RB experiment at FAIR, has been performed using particle induced X-ray emission. No statistically significant gradient in doping level was found along the long axis of the investigated sample crystal and the mean value of the Tl concentration was measured to be 0.0839(38)% by weight. This corresponds to a light output of 97.3 % relative to the maximum attainable light output according to previously published work. By taking the ±1σ bounds, the 3% statistical spread in the relative light output provides a good reference value of the minimum light-output non-uniformity observed for the CALIFA crystals. If the relative light output is estimated pointwise from a set of Tl concentration measurements a light-output non-uniformity of 4.6(2.4)% results. For a γ-ray energy of 662 keV the deduced variation in Tl concentration contributes with 0.48(6)% to the typical resolution of 7.74(6)% measured with a collimated source along the crystal main axis. The result is of interest for the characterization of the detector system performance and for realistic simulations of the light collection process in detector systems that are used for nuclear spectroscopy and calorimetry., This work was supported by the Swedish research council (VR) grants 2017-03986, 2014-06644, 2013-04178, 2012-04550, BMBF contracts 05P15WOFNA, 05P19WOFN1, 05P15RDFN1, 05P19RDFN1, the TU Darmstadt – GSI cooperation contract HIC for FAIR, by the Spanish National Research Council, Spain grants FPA02015-64969-P (MINDECO/FEDER/EU), FPA2015-69640-C2-1-P, PGC2018-099746-B-C21, MDM-2016.0692 (MINECO/FEDER/EU) and by GRC, Germany ED431C 2017/54 (Xunta de Galicia/FEDER/EU).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Sensitivity of a tonne-scale NEXT detector for neutrinoless double-beta decay searches

  • Weiss-Babai, R.
  • Rogero, Celia
  • Cárcel, Sara
  • Carrión, J. V.
  • Díaz, J.
  • Felkai, R.
  • López-March, Neus
  • Martín-Albo, Justo
  • Martínez, Alejandro
  • Martínez-Vara, M.
  • Muñoz Vidal, J.
  • Novella, Pau
  • Palmeiro, Brais
  • Romo-Luque, Carmen
  • Sorel, Michel
  • Usón, A.
  • Yahlali, Nadia
  • Álvarez Puerta, Vicente
  • Ballester, F.
  • Esteve, Raúl
  • Herrero Bosch, Vicente
  • Mora, Francisco José
  • Rodríguez, J.
  • Toledo, J. F.
The NEXT collaboration: et al., The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta (0νββ) decay of 136Xe using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of 0νββ decay better than 1027 years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the inverted ordering of neutrino masses, and beyond., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union’s Framework Programme for Research and Innovation Horizon 2020 (2014–2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economía y Competitividad and the Ministerio de Ciencia, Innovación y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the María de Maeztu Program MDM2016-0692; the Generalitat Valenciana of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under grants 877040 and 877041; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223 / DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges support from the Ramón y Cajal program (Spain) under contract number RYC-2015-18820. JM-A acknowledges support from Fundación Bancaria la Caixa (ID 100010434), grant code LCF/BQ/PI19/11690012, and from the Plan GenT program of the Generalitat Valenciana, grant code CIDEGENT/2019/049., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Measurement of the 136Xe two-neutrino double- β -decay half-life via direct background subtraction in NEXT

  • Novella, Pau
  • Sorel, Michel
  • Usón, A.
  • Álvarez Puerta, Vicente
  • Ballester, F.
  • Cárcel, Sara
  • Carrión, J. V.
  • Díaz, J.
  • Esteve, Raúl
  • Herrero-Gómez, P.
  • Herrero Bosch, Vicente
  • López-March, Neus
  • Martínez, Alejandro
  • Martínez-Vara, M.
  • Mora, Francisco José
  • Muñoz Vidal, J.
  • Palmeiro, Brais
  • Querol, Marc
  • Rodríguez, J.
  • Rogero, Celia
  • Romo-Luque, Carmen
  • Toledo, J. F.
  • Yahlali, Nadia
NEXT Collaboration: et al., We report a measurement of the half-life of the 136Xe two-neutrino double-β decay performed with a novel direct-background-subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with 136Xe-enriched and 136Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of 2.34+0.80−0.46(stat)+0.30−0.17(sys)×1021yr is derived from the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double-β-decay searches., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant No.951281-BOLD; the European Union’s Framework Programme for Research and Innovation Horizon 2020 (2014–2020) under Grant No. 957202-HIDDEN; the MCIN/AEI/10.13039/501100011033 of Spain and ERDF “Away of making Europe” under Grant No.RTI2018-095979, the Severo Ochoa Program Grant No.CEX2018-000867-S, and the María de Maeztu Program Grant No.MDM-2016-0692; the Generalitat Valenciana of Spain under Grants No. PROMETEO/2021/087 and No. CIDEGENT/2019/049; the Portuguese FCT under Project No. UID/FIS/04559/2020 to fund the activities of LIB Phys-UC; the Pazy Foundation (Israel) under Grants No.877040 and No.877041; the U.S. Department of Energy under Contracts No.DE-AC02-06CH11357(Argonne National Laboratory),No. DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), No. DE-FG02-13ER42020 (TexasA&M),No.DE-SC0019054 (Texas Arlington), and No.DE-SC0019223 (Arlington,TX); the U.S. National Science Foundation under Grant No. CHE2004111;and the Robert A. Welch Foundation under Grant No.Y-203120200401. D.G.D. acknowledges support from the Ramón y Cajal program (Spain) under Contract No. RYC-2015-18820., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

The dynamics of ions on phased radio-frequency carpets in high pressure gases and application for barium tagging in xenon gas time projection chambers

  • Jones, B.J.P.
  • Álvarez Puerta, Vicente
  • Ballester, F.
  • Cárcel, Sara
  • Carrión, J. V.
  • Díaz, J.
  • Esteve, Raúl
  • Herrero-Gómez, P.
  • Herrero Bosch, Vicente
  • López-March, Neus
  • Martín-Albo, Justo
  • Martínez, Alejandro
  • Martínez-Vara, M.
  • Mora, Francisco José
  • Muñoz Vidal, J.
  • Novella, Pau
  • Palmeiro, Brais
  • Querol, Marc
  • Rodríguez, J.
  • Rogero, Celia
  • Romo-Luque, Carmen
  • Sorel, Michel
  • Toledo, J. F.
  • Usón, A.
  • Yahlali, Nadia
NEXT Collaboration: et al., Radio-frequency (RF) carpets with ultra-fine pitches are examined for ion transport in gases at atmospheric pressures and above. We develop new analytic and computational methods for modeling RF ion transport at densities where dynamics are strongly influenced by buffer gas collisions. An analytic description of levitating and sweeping forces from phased arrays is obtained, then thermodynamic and kinetic principles are used to calculate ion loss rates in the presence of collisions. This methodology is validated against detailed microscopic SIMION simulations. We then explore a parameter space of special interest for neutrinoless double beta decay experiments: transport of barium ions in xenon at pressures from 1 to 10 bar. Our computations account for molecular ion formation and pressure dependent mobility as well as finite temperature effects. We discuss the challenges associated with achieving suitable operating conditions, which lie beyond the capabilities of existing devices, using presently available or near-future manufacturing techniques., The University of Texas at Arlington NEXT group is supported by the Department of Energy, USA under Early Career Award number DE-SC0019054 (BJPJ), by Department of Energy, USA Award DE-SC0019223 (DRN), the National Science Foundation, USA under award number NSF CHE 2004111 (FWF), and the Robert A Welch Foundation, Y-2031-20200401 (FWF). The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union’s Framework Programme for Research and Innovation Horizon 2020 (2014–2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economía Competitividad and the Ministerio de Ciencia, Innovación Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the María de Maeztu Program MDM-2016-0692; from Fundacion Bancaria la Caixa (ID 100010434), grant code LCF/BQ/PI19/11690012; the Generalitat Valenciana of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under grants 877040 and 877041; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory, USA), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M). DGD acknowledges support from the Ramón y Cajal program (Spain) under contract number RYC-2015-18820. JM-A acknowledges support from Fundación Bancaria la Caixa (ID 100010434), grant code LCF/BQ/PI19/11690012, and from the Plan GenT program of the Generalitat Valenciana , grant code CIDEGENT/2019/049., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Quantum gravity phenomenology at the dawn of the multi-messenger era—A review

  • Addazi, A.
  • Alvarez-Muñiz, Jaime
  • Alves Batista, R.
  • Calcagni, Gianluca
  • Carmona, José Manuel
  • Palomares Ruiz, Sergio
  • Sopuerta, Carlos F.
  • Martínez-Miravé, Pablo
  • Tórtola, Mariam
  • Zornoza, J. D.
A. Addazi, J. Alvarez-Muniz, R.A. Batista et al., The exploration of the universe has recently entered a new era thanks to the multi-messenger paradigm, characterized by a continuous increase in the quantity and quality of experimental data that is obtained by the detection of the various cosmic messengers (photons, neutrinos, cosmic rays and gravitational waves) from numerous origins. They give us information about their sources in the universe and the properties of the intergalactic medium. Moreover, multi-messenger astronomy opens up the possibility to search for phenomenological signatures of quantum gravity. On the one hand, the most energetic events allow us to test our physical theories at energy regimes which are not directly accessible in accelerators; on the other hand, tiny effects in the propagation of very high energy particles could be amplified by cosmological distances. After decades of merely theoretical investigations, the possibility of obtaining phenomenological indications of Planck-scale effects is a revolutionary step in the quest for a quantum theory of gravity, but it requires cooperation between different communities of physicists (both theoretical and experimental). This review, prepared within the COST Action CA18108 “Quantum gravity phenomenology in the multi-messenger approach”, is aimed at promoting this cooperation by giving a state-of-the art account of the interdisciplinary expertise that is needed in the effective search of quantum gravity footprints in the production, propagation and detection of cosmic messengers., Talent Scientific Research Program of College of Physics, Sichuan University, Grant No. 1082204112427; the Fostering Program in Disciplines Possessing Novel Features for Natural Science of Sichuan University, Grant No. 2020SCUNL209; 1000 Talent program of Sichuan province 2021; Xunta de Galicia (Centro singular de investigación de Galicia accreditation 2019–2022); European Union ERDF, “María de Maeztu” Units of Excellence program (MDM-2016-0692); Red Temática Nacional de Astropartículas (RED2018-102661-T); “la Caixa” Foundation (ID 100010434); European Union’s Horizon 2020 research and innovation program under the Marie Skłodowska-Curie grant agreement No. 847648, fellowship code LCF/BQ/PI21/11830030, and grant agreement No. 754510; Serbian Ministry of Education, Science and Technological Development Contract No. (451-03-9/2021-14/200124); FSR Incoming Postdoctoral Fellowship Ministry of Education, Science and Technological Development, Serbia (451-03-9/2021-14/200124); University of Rijeka grant (uniri-prirod-18-48); Croatian Science Foundation (HRZZ) project number IP-2016-06-9782; Villum Fonden (29405); DGA-FSE [2020-E21-17R]; European Regional Development Fund through the Center of Excellence (TK133) “The Dark Side of the Universe”; European Regional Development Fund (ESIF/ERDF) and the Czech Ministry of Education, Youth and Sports (MŠMT) [Project CoGraDS-CZ.02.1.01/0.0/0.0/15 003/0000437]; Blavatnik & Rothchild grants; Basque Government grant (IT-979-16); Basque Foundation for Science (IKERBASQUE); ESA Prodex grants C4000120711, 4000132310; FNRS (Belgian Fund for Research); DGAPA-PAPIIT-UNAM [TA100122]; UNLP (X909); DICYT 042131GR (J.G.); Hungarian National Research Development and Innovation Office NKFIH (Grant No. 123996); FQXi; Swiss National Science Foundation (181461, 199307); Nederlandse Organisatie voor Wetenschappelijk Onderzoek - NWO (grant numbers 680-91-119, 15MV71, and sectorplan); Japan Society for the Promotion of Science KAKENHI Grant (20H01899, 20H05853 and JP21F21789); Estonian Research Council grants (PRG356) “Gauge Gravity”, and MOBTT5; Julian Schwinger Foundation; Generalitat Valenciana Excellence Grant [PROMETEO-II/2017/033] and [PROMETEO/2018/165]; Istituto Nazionale di Fisica Nucleare (INFN) Iniziativa Specifica TEONGRAV, Iniziativa Specifica QGSKY, Iniziativa Specifica QUAGRAP and Iniziativa Specifica GeoSymQFT; European ITN project HIDDeN (H2020-MSCA-ITN-2019//860881-HIDDeN); Swedish Research Council (2016-05996); European Research Council (668679); Advanced ERC grant TReX; Research grant “The Dark Universe: A Synergic Multimessenger Approach”, No. [2017X7X85K] under the program PRIN 2017 funded by the Ministero dell’Istruzione, Universit‘a e della Ricerca (MIUR); MIUR through the “Dipartimenti di eccellenza” project Science of the Universe; Research Council of University of Guilan; I.I.S.N. project 4.4501.18; Romanian Ministry of Research Innovation and Digitalization through the projects No. PN19-030102-INCDFM and CNCS - UEFISCDI No. PN-III-P4-ID-PCE-2020-2374; U.S. Department of Energy (DE-SC0020262, Task C); State project “Science” by the Ministry of Science and Higher Education of the Russian Federation (075-15-2020-778); German Academic Scholarship Foundation; Deutsche Forschungsgemeinschaft - DFG - through grant numbers (408049454, 420243324, 425333893, 445990517) and under Germany’s Excellence Strategy (EXC 2121 “Quantum Universe” – 390833306, EXC 2123 “QuantumFrontiers” - 390837967); Bundesministerium für Bildung und Forschung - BMBF (grants 05 A20GU2 and 05 A20PX1); Centro de Excelencia “Severo Ochoa” (SEV-2016-0588); CERCA program of the Generalitat de Catalunya; AGAUR, Generalitat de Catalunya (2017-SGR-1469, 2017-SGR-929); ICCUB (CEX2019-000918-M); National Science Centre (2019/33/B/ST2/00050) and (2017/27/B/ST2/01902); National Council for Scientific and Technological Development - CNPq [306414/2020-1]; Dicyt-USACH (041931MF); Bulgarian NSF grant KP-06-N 38/11; RCN ROMFORSK grant project. no. 302640; Comunidad de Madrid, Spain, “Atracción de Talento Investigador” programme, grants No. 2018-T1/TIC-10431 and 2019-T1/TIC-13177; Comunidad de Madrid, Spain (S2018/NMT-4291 “TEC2SPACECM“, “Desarrollo y explotación de nuevas tecnologías para instrumentación espacial en la Comunidad de Madrid”); Science and Technology Facilities Council (STFC) UK, grants ST/T000759/1, ST/P000258/1, ST/T000732/1, ST/V005596/1; Fundação para a Ciência e a Tecnologia, Portugal, projects UIDB/00618/2020, UIDB/00777/2020, UIDP/00777/2020, CERN/FIS-PAR/0004/2019, PTDC/FIS-PAR/29436/2017, PTDC/FIS-PAR/31938/2017, PTDC/FIS-OUT/29048/2017, and grant SFRH/BD/137127/2018; UID/MAT/00212/2020; FPU18/04571; Centre National de la Recherche Scientifique (CNRS), LabEx UnivEarthS (ANR-10-LABX-0023 and ANR18-IDEX-0001); Junta de Andalucía [ref. A-FQM-053-UGR18], Spain; NSERC (RGPIN-2021-03644); National Science Centre Poland Sonata Bis Grant No. DEC-2017/26/E/ST2/00763 and Project No. 2019/33/B/ST2/00050; Natural Sciences and Engineering Research Council; DGIID-DGA (2015-E24/2); Spanish Research State Agency and Ministerio de Ciencia e Innovación MCIN/AEI/10.13039/501100011033: PID2019-104114RB-C32, PID2019-105544GB-I00, PID2019-105614GB-C21, PID2019-106515GB-I00, PID2019-106802GB-I00, PID2019-107394GB-I00, PID2019-107844GB-C21, PID2019-107847RB-C41, PID2019-108485GB-I00, PID2020-113334GB-I00, PID2020-113701GB-I00, PID2020-113775GB-I00, PID2020-115845GB-I00, PID2020-118159GB-C41, PID2020-118159GA-C42, PRE2019-089024; MCIN/AEI/10.13039/501100011033/FEDER: PGC2018-095328-B-I00, PGC2018-094856-B-I00, PGC2018-096663-B-C41, PGC2018-096663-B-C44, PGC2018-094626-B-C21, PGC2018-101858-B-I00, FPA2017-84543-P, FPA2016-76005-C2-1-P; Ayuda Beatriz Galindo Senior’ from the Spanish ‘Ministerio de Universidades’, grant BG20/00228, and the Spanish Ministry of Science and Innovation PID2020-115845GB-I00/AEI/10.13039/501100011033. IFAE is partially funded by the CERCA program of the Generalitat de Catalunya; Comunidad de Madrid S2018/NMT-4291 TEC2SPACE-CM; Ministerio de Economía, Industria y Competitividad, Spain (PID2019-105544GB-I00)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Production of carbon‑11 for PET preclinical imaging using a high‑repetition rate laser‑driven proton source

  • Peñas, Juan
  • Alejo, Aarón
  • Bembibre, Adrián
  • Apiñaniz, Jon Imanol
  • García-García, Enrique
  • Guerrero, C.
  • Henares, José Luis
  • Hernández-Palmero, Irene
  • Méndez, Cruz
  • Millán Callado, María de los Ángeles
  • Puyuelo-Valdés, Pilar
  • Seimetz, Michael
  • Benlliure, José
Most advanced medical imaging techniques, such as positron-emission tomography (PET), require tracers that are produced in conventional particle accelerators. This paper focuses on the evaluation of a potential alternative technology based on laser-driven ion acceleration for the production of radioisotopes for PET imaging. We report for the first time the use of a high-repetition rate, ultra-intense laser system for the production of carbon-11 in multi-shot operation. Proton bunches with energies up to 10-14 MeV were systematically accelerated in long series at pulse rates between 0.1 and 1 Hz using a PW-class laser. These protons were used to activate a boron target via the 11 B(p,n) 11 C nuclear reaction. A peak activity of 234 kBq was obtained in multi-shot operation with laser pulses with an energy of 25 J. Significant carbon-11 production was also achieved for lower pulse energies. The experimental carbon-11 activities measured in this work are comparable to the levels required for preclinical PET, which would be feasible by operating at the repetition rate of current state-of-the-art technology (10 Hz). The scalability of next-generation laser-driven accelerators in terms of this parameter for sustained operation over time could increase these overall levels into the clinical PET range., This work has received financial support by the María de Maetzu Units of Excellence program MDM-2016-0692-17-2, and by the Spanish Ministerio de Ciencia, Innovación y Universidades under RTI2018-098117-B-C21, RTI2018-101578-B-C21, RTI2018-101578-B-C22, and FPI predoctoral BES-2017-08917 grants, and the Xunta de Galicia grants GRC ED431C 2017/54 and ED431F2023/21. It also was supported by Generalitat Valenciana, grant AICO/2020/207. Action co-financied by the European Union through the Programa Operativo del Fondo Europeo de Desarrollo Regional (FEDER). This work was supported by ‘la Caixa’ Foundation (ID 100010434) [fellowship code LCF/BQ/PI20/11760027], and grant RYC2021-032654-I funded by MCIN, AEI and by ‘European Union NextGenerationEU., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

The NEXT White (NEW) detector

  • Monrabal, F.
  • Gomez-Cadenas, J.J.
  • Toledo, J.F.
  • Laing, A.
  • Alvarez, V.
  • Benlloch-Rodriguez, J.M.
  • Carcel, S.
  • Carrion, J.
  • Esteve, R.
  • Felkai, R.
  • Herrero, V.
  • Martinez, A.
  • Musti, M.
  • Ouero, M.
  • Rodriguez, J.
  • Simon, A.
  • Sofka, C.
  • Torrent, J.
  • Webb, R.
  • White, J.T.
  • Adams, C.
  • Arazi, L.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cebrian, S.
  • Conde, C.A.N.
  • Diaz, J.
  • Diesburg, M.
  • Escada, J.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferrario, I.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Goldschmidt, A.
  • Gonzalez-Daaz, D.
  • Guenette, R.
  • Gutierrez, R.M.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernandez, A.I.
  • Morata, J.A.H.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Lebrun, P.
  • Lopez-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martin-Albo, J.
  • Martinez-Lema, G.
  • McDonald, A.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Vidal, J.M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Perez, J.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rogers, L.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Sorel, M.
  • Stiegler, T.
  • Veloso, J.F.C.A.
  • Yahlali, N.
Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT-White apparatus is currently the largest high pressure xenon gas TPC using electroluminescent amplification in the world. It is also a 1:2 scale model of the NEXT-100 detector for Xe-136 beta beta 0 nu decay searches, scheduled to start operations in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2016 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. This paper describes the detector and associated infrastructures, as well as the main aspects of its initial operation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Electroluminescence TPCs at the thermal diffusion limit

  • Henriques, C.A.O.
  • Monteiro, C.M.B.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Freitas, E.D.C.
  • Mano, R.D.P.
  • Jorge, M.R.
  • Fernandes, A.F.M.
  • Gómez-Cadenas, J.J.
  • Fernandes, L.M.P.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Ferrario, P.
  • Ferreira, A.L.
  • Generowicz, J.
  • Goldschmidt, A.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Hafidi, K.
  • Hauptman, J.
  • Hernandez, A.I.
  • Hernando Morata, J.A.
  • Herrero, V.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • McDonald, A.
  • Monrabal, F.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Musti, M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Psihas, F.
  • Querol, M.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez, J.
  • Rogers, L.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the 136Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO2, CH4 and CF4) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/m for pure xenon down to 2.5 mm/m using additive concentrations of about 0.05%, 0.2% and 0.02% for CO2, CH4 and CF4, respectively. Our results show that CF4 admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH4 presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO2 and CH4 show potential as molecular additives in a large xenon TPC. While CO2 has some operational constraints, making it difficult to be used in a large TPC, CH4 shows the best performance and stability as molecular additive to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%, which is only slightly worse than the one obtained for pure xenon. We demonstrate the possibility to have an electroluminescence TPC operating very close to the thermal diffusion limit without jeopardizing the TPC performance, if CO2 or CH4 are chosen as additives.[Figure not available: see fulltext.]
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Radiogenic backgrounds in the NEXT double beta decay experiment

  • Novella P.
  • Palmeiro B.
  • Sorel M.
  • Usón A.
  • Ferrario P.
  • Gómez-Cadenas J.J.
  • Adams C.
  • Álvarez V.
  • Arazi L.
  • Arnquist I.J.
  • Azevedo C.D.R.
  • Bailey K.
  • Ballester F.
  • Benlloch-Rodríguez J.M.
  • Borges F.I.G.M.
  • Byrnes N.
  • Cárcel S.
  • Carrión J.V.
  • Cebrían S.
  • Church E.
  • Conde C.A.N.
  • Contreras T.
  • Díaz G.
  • Díaz J.
  • Diesburg M.
  • Escada J.
  • Esteve R.
  • Felkai R.
  • Fernandes A.F.M.
  • Fernandes L.M.P.
  • Ferreira A.L.
  • Freitas E.D.C.
  • Generowicz J.
  • Ghosh S.
  • Goldschmidt A.
  • Gonzalez-Díaz D.
  • Guenette R.
  • Gutiérrez R.M.
  • Haefner J.
  • Hafidi K.
  • Hauptman J.
  • Henriques C.A.O.
  • Hernando Morata J.A.
  • Herrero P.
  • Herrero V.
  • Ifergan Y.
  • Johnston S.
  • Jones B.J.P.
  • Kekic M.
  • Labarga L.
  • Laing A.
  • Lebrun P.
  • López-March N.
  • Losada M.
  • Mano R.D.P.
  • Martín-Albo J.
  • Martínez A.
  • Martínez-Lema G.
  • McDonald A.D.
  • Monrabal F.
  • Monteiro C.M.B.
  • Mora F.J.
  • Muñoz Vidal J.
  • Nygren D.R.
  • Para A.
  • Pérez J.
  • Psihas F.
  • Querol M.
  • Renner J.
  • Repond J.
  • Riordan S.
  • Ripoll L.
  • Rodríguez García Y.
  • Rodríguez J.
  • Rogers L.
  • Romeo B.
  • Romo-Luque C.
  • Santos F.P.
  • dos Santos J.M.F.
  • Simón A.
  • Sofka C.
  • Stiegler T.
  • Toledo J.F.
  • Torrent J.
  • Veloso J.F.C.A.
  • Webb R.
  • Weiss-Babai R.
  • White J.T.
  • Woodruff K.
  • Yahlali N.
  • The NEXT collaboration
Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity- induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterráneo de Canfranc with xenon depleted in 136Xe are analyzed to derive a total background rate of (0.84±0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEXT collaboration. A spectral fit to this model yields the specific contributions of 60Co, 40K, 214Bi and 208Tl to the total background rate, as well as their location in the detector volumes. The results are used to evaluate the impact of the radiogenic backgrounds in the double beta decay analyses, after the application of topological cuts that reduce the total rate to (0.25±0.01) mHz. Based on the best-fit background model, the NEXT-White median sensitivity to the two-neutrino double beta decay is found to be 3.5s after 1 year of data taking. The background measurement in a Qßß±100 keV energy window validates the best-fit background model also for the neutrinoless double beta decay search with NEXT-100. Only one event is found, while the model expectation is (0.75±0.12) events.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Energy calibration of the NEXT-White detector with 1% resolution near Qßß of 136Xe

  • Renner, J.
  • Díaz López, G.
  • Ferrario, P.
  • Hernando Morata, J.A.
  • Kekic, M.
  • Martínez-Lema, G.
  • Monrabal, F.
  • Gómez-Cadenas, J.J.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Ghosh, S.
  • Goldschmidt, A.
  • González-Díaz, D.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Haefner, J.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Johnston, S.
  • Jones, B.J.P.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martín-Albo, J.
  • Martínez, A.
  • McDonald, A.D.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Psihas, F.
  • Querol, M.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez García, Y.
  • Rodríguez, J.
  • Rogers, L.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Woodruff, K.
  • Yahlali, N.
  • The NEXT collaboration
Excellent energy resolution is one of the primary advantages of electroluminescent high-pressure xenon TPCs. These detectors are promising tools in searching for rare physics events, such as neutrinoless double-beta decay (ßß0¿), which require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1% FWHM can be achieved at 2.6 MeV, establishing the present technology as the one with the best energy resolution of all xenon detectors for ßß0¿ searches. [Figure not available: see fulltext.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Demonstration of the event identification capabilities of the NEXT-White detector

  • Ferrario P.
  • Benlloch-Rodríguez J.M.
  • Díaz López G.
  • Hernando Morata J.A.
  • Kekic M.
  • Renner J.
  • Usón A.
  • Gómez-Cadenas J.J.
  • Adams C.
  • Álvarez V.
  • Arazi L.
  • Arnquist I.J.
  • Azevedo C.D.R.
  • Bailey K.
  • Ballester F.
  • Borges F.I.G.M.
  • Byrnes N.
  • Cárcel S.
  • Carrión J.V.
  • Cebrían S.
  • Church E.
  • Conde C.A.N.
  • Contreras T.
  • Díaz J.
  • Diesburg M.
  • Escada J.
  • Esteve R.
  • Felkai R.
  • Fernandes A.F.M.
  • Fernandes L.M.P.
  • Ferreira A.L.
  • Freitas E.D.C.
  • Generowicz J.
  • Ghosh S.
  • Goldschmidt A.
  • González-Díaz D.
  • Guenette R.
  • Gutíerrez R.M.
  • Haefner J.
  • Hafidi K.
  • Hauptman J.
  • Henriques C.A.O.
  • Herrero P.
  • Herrero V.
  • Ifergan Y.
  • Johnston S.
  • Jones B.J.P.
  • Labarga L.
  • Laing A.
  • Lebrun P.
  • López-March N.
  • Losada M.
  • Mano R.D.P.
  • Martín-Albo J.
  • Martínez A.
  • Martínez-Lema G.
  • McDonald A.D.
  • Monrabal F.
  • Monteiro C.M.B.
  • Mora F.J.
  • Muñoz Vidal J.
  • Novella P.
  • Nygren D.R.
  • Palmeiro B.
  • Para A.
  • Pérez J.
  • Psihas F.
  • Querol M.
  • Repond J.
  • Riordan S.
  • Ripoll L.
  • Rodríguez García Y.
  • Rodríguez J.
  • Rogers L.
  • Romeo B.
  • Romo-Luque C.
  • Santos F.P.
  • dos Santos J.M.F.
  • Simón A.
  • Sofka C.
  • Sorel M.
  • Stiegler T.
  • Toledo J.F.
  • Torrent J.
  • Veloso J.F.C.A.
  • Webb R.
  • Weiss-Babai R.
  • White J.T.
  • Woodruff K.
  • Yahlali N.
  • The NEXT collaboration
In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a 228Th calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of 71.6 ± 1.5 stat± 0.3 sys% for a background acceptance of 20.6 ± 0.4 stat± 0.3 sys% is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies. [Figure not available: see fulltext.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

  • Fernandes, A.F.M.
  • Henriques, C.A.O.
  • Mano, R.D.P.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Silva, P.A.O.C.
  • Gómez-Cadenas, J.J.
  • Freitas, E.D.C.
  • Fernandes, L.M.P.
  • Monteiro, C.M.B.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, G.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Ferrario, P.
  • Ferreira, A.L.
  • Generowicz, J.
  • Ghosh, S.
  • Goldschmidt, A.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Haefner, J.
  • Hafidi, K.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • McDonald, A.D.
  • Monrabal, F.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Psihas, F.
  • Querol, M.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez García, Y.
  • Rodríguez, J.
  • Rogers, L.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Woodruff, K.
  • Yahlali, N.
  • The NEXT collaboration
High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe–He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the EL region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air

  • Ghosh, S.
  • Haefner, J.
  • Martín-Albo, J.
  • Guenette, R.
  • Li, X.
  • Loya Villalpando, A.A.
  • Burch, C.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, G.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernando Morata, J.A.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martínez, A.
  • Martínez-Vara, M.
  • Martínez-Lema, G.
  • McDonald, A.D.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Redwine, A.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez García, Y.
  • Rodríguez, J.
  • Rogers, L.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Woodruff, K.
  • Yahlali, N.
  • The, NEXT, collaboration
Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm. We also see that the reflectance of PTFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance in the visible without introducing a specular component in the reflectance.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Mitigation of backgrounds from cosmogenic 137Xe in xenon gas experiments using 3He neutron capture

  • Rogers, L.
  • Jones, B.J.P.
  • Laing, A.
  • Pingulkar, S.
  • Smithers, B.
  • Woodruff, K.
  • Adams, C.
  • Lvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, G.
  • Díaz, J.
  • Diesburg, M.
  • Dingler, R.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Ghosh, S.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Haefner, J.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Morata, J.A.H.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Johnston, S.
  • Kekic, M.
  • Labarga, L.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • McDonald, A.D.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Vidal, J.M.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Redwine, A.B.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • García, Y.R.
  • Rodríguez, J.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • Dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Yahlali, N.
136Xe is used as the target medium for many experiments searching for 0¿ßß. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of 137Xe created by the capture of neutrons on 136Xe. This isotope decays via beta decay with a half-life of 3.8 min and a Q ß of ~4.16 MeV. This work proposes and explores the concept of adding a small percentage of 3He to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from 137Xe activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Sensitivity of the NEXT experiment to Xe-124 double electron capture

  • Martínez-Lema, G.
  • Martínez-Vara, M.
  • Sorel, M.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, G.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Ghosh, S.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Haefner, J.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernando Morata, J.A.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martín-Albo, J.
  • Martínez, A.
  • McDonald, A.D.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Redwine, A.B.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez García, Y.
  • Rodríguez, J.
  • Rogers, L.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Woodruff, K.
  • Yahlali, N.
  • The, NEXT, collaboration
Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture (2¿EC EC) has been predicted for a number of isotopes, but only observed in 78Kr, 130Ba and, recently, 124Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, 0¿EC EC. Here we report on the current sensitivity of the NEXT-White detector to 124Xe 2¿EC EC and on the extrapolation to NEXT-100. Using simulated data for the 2¿EC EC signal and real data from NEXT-White operated with 124Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124Xe and for a 5-year run, a sensitivity to the 2¿EC EC half-life of 6 × 1022 y (at 90% confidence level) or better can be reached. [Figure not available: see fulltext.]
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Reseña (Review)

Quantum gravity phenomenology at the dawn of the multi-messenger era—A review

  • Addazi, A.
  • Alvarez-Muniz, J.
  • Alves Batista, R.
  • Amelino-Camelia, G.
  • Antonelli, V.
  • Arzano, M.
  • Asorey, M.
  • Atteia, J.L.
  • Bahamonde, S.
  • Bajardi, F.
  • Ballesteros, A.
  • Baret, B.
  • Barreiros, D. M.
  • Basilakos, S.
  • Benisty, D.
  • Birnholtz, O.
  • Blanco-Pillado, J.
  • Blas, D.
  • Bolmont, J.
  • Boncioli, D.
  • Bosso, P.
  • Calcagni, G.
  • Capozziello, S.
  • Carmona, J. M.
  • Cerci, S.
  • Chernyakova, M.
  • Clesse, S.
  • Coelho, J. A. B.
  • Colak, S. M.
  • Cortes, J. L.
  • Das, S.
  • D''Esposito, V.
  • Demirci, M.
  • Di Luca, M. G.
  • di Matteo, A.
  • Dimitrijevic, D.
  • Djordjevic, G.
  • Prester, D. D.
  • Eichhorn, A.
  • Ellis, J.
  • Escamilla-Rivera, C.
  • Fabiano, G.
  • Franchino-Viñas, S. A.
  • Frassino, A. M.
  • Frattulillo, D.
  • Funk, S.
  • Fuster, A.
  • Gamboa, J.
  • Gent, A.
  • Gergely, L. Á.
  • Giammarchi, M.
  • Giesel, K.
  • Glicenstein, J.F.
  • Gracia-Bondía, J.
  • Gracia-Ruiz, R.
  • Gubitosi, G.
  • Guendelman, E. I.
  • Gutierrez-Sagredo, I. Haegel, L.
  • Heefer, S.
  • Held, A.
  • Herranz, F. J.
  • Hinderer, T.
  • Illana, J. I.
  • Ioannisian, A.
  • Jetzer, P.
  • Joaquim, F. R.
  • Kampert, K.H.
  • Uysal, A. K.
  • Katori, T.
  • Kazarian, N.
  • Kerszberg, D.
  • Kowalski-Glikman, J.
  • Kuroyanagi, S.
  • Lämmerzahl, C.
  • Said, J. L.
  • Liberati, S.
  • Lim, E.
  • Lobo, I. P.
  • López-Moya, M.
  • Luciano, G. G.
  • Manganaro, M.
  • Marcianò, A.
  • Martín-Moruno, P.
  • Martinez, M.
  • Martinez, M.
  • Martínez-Huerta, H.
  • Martínez-Miravé, P.
  • Masip, M.
  • Mattingly, D.
  • Mavromatos, N.
  • Mazumdar, A.
  • Méndez, F.
  • Mercati, F.
  • Micanovic, S.
  • Mielczarek, J.
  • Miller, A. L.
  • Milosevic, M.
  • Minic, D.
  • Miramonti, L.
  • Mitsou, V. A.
  • Moniz, P.
  • Mukherjee, S.
  • Nardini, G.
  • Navas, S.
  • Niechciol, M.
  • Nielsen, A. B.
  • Obers, N. A.
  • Oikonomou, F.
  • Oriti, D.
  • Paganini, C. F.
  • Palomares-Ruiz, S.
  • Pasechnik, R.
  • Pasic, V.
  • Pérez de los Heros, C.
  • Pfeifer, C.
  • Pieroni, M.
  • Piran, T.
  • Platania, A.
  • Rastgoo, S.
  • Relancio, J. J.
  • Reyes, M. A.
  • Ricciardone, A.
  • Risse, M.
  • Frias, M. D. R.
  • Rosati, G.
  • Rubiera-Garcia, D.
  • Sahlmann, H.
  • Sakellariadou, M.
  • Salamida, F.
  • Saridakis, E. N.
  • Satunin, P.
  • Schiffer, M.
  • Schüssler, F.
  • Sigl, G.
  • Sitarek, J.
  • Peracaula, J. S.
  • Sopuerta, C. F.
  • Sotiriou, T. P.
  • Spurio, M.
  • Staicova, D.
  • Stergioulas, N.
  • Stoica, S.
  • Striškovic, J.
  • Stuttard, T.
  • Cerci, D. S.
  • Tavakoli, Y.
  • Ternes, C. A.
  • Terzic, T.
  • Thiemann, T.
  • Tinyakov, P.
  • Torri, M. D. C.
  • Tórtola, M.
  • Trimarelli, C.
  • Trzesniewski, T.
  • Tureanu, A.
  • Urban, F. R.
  • Vagenas, E. C.
  • Vernieri, D.
  • Vitagliano, V.
  • Wallet, J.C.
  • Zornoza, J. D.
The exploration of the universe has recently entered a new era thanks to the multi-messenger paradigm, characterized by a continuous increase in the quantity and quality of experimental data that is obtained by the detection of the various cosmic messengers (photons, neutrinos, cosmic rays and gravitational waves) from numerous origins. They give us information about their sources in the universe and the properties of the intergalactic medium. Moreover, multi-messenger astronomy opens up the possibility to search for phenomenological signatures of quantum gravity. On the one hand, the most energetic events allow us to test our physical theories at energy regimes which are not directly accessible in accelerators; on the other hand, tiny effects in the propagation of very high energy particles could be amplified by cosmological distances. After decades of merely theoretical investigations, the possibility of obtaining phenomenological indications of Planck-scale effects is a revolutionary step in the quest for a quantum theory of gravity, but it requires cooperation between different communities of physicists (both theoretical and experimental). This review, prepared within the COST Action CA18108 “Quantum gravity phenomenology in the multi-messenger approach”, is aimed at promoting this cooperation by giving a state-of-the art account of the interdisciplinary expertise that is needed in the effective search of quantum gravity footprints in the production, propagation and detection of cosmic messengers. © 2022 The Authors