Generalized multifrequency current controller for grid-connected converters with LCL filter

  • Pérez Estévez, Diego
  • Doval Gandoy, Jesús
  • Gómez Yepes, Alejandro
  • López Sánchez, Óscar
  • Baneira Collazo, Fernando
This paper presents a grid-side current controller for grid-tied inverters with LCL filter, including harmonic current elimination. The proposed controller only measures the grid current and voltage and it combines excellent dynamic characteristics with good robustness. Contrarily to previously proposed harmonic-current controllers, the presented solution offers a generalized method that gives a consistent (with minimal variation in the reference-tracking dynamics) and stable performance irrespectively of the number of current harmonics to be canceled and of the resonant frequency of the LCL filter (provided that it is lower than the Nyquist frequency). The response to reference commands is completely damped and fast. The response speed is set in accordance with the low-pass characteristic of the LCL filter so as to limit the control effort. Concerning the disturbance rejection, the controller offers an infinite impedance to any disturbances (such as grid voltage harmonics) at a set of arbitrarily specified frequencies. This allows the designer to eliminate all the undesired current harmonics with a simple design process. In addition, the performance of the presented controller is evaluated in terms of a fundamental tradeoff that exists between robustness to variations in the grid impedance and the number of frequency components rejected. Finally, simulation and experimental results that validate the proposal are presented., Ministerio de Ciencia e Innovación, European Commission, Agencia Estatal de Investigación | Ref. DPI2016-75832-R, Ministerio de Educación, Cultura y Deporte | Ref. FPU14/00683
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Ac-voltage harmonic control for stand-alone and weak-grid-tied converter

  • Pérez Estévez, Diego
  • Doval Gandoy, Jesús
  • Guerrero, Josep M
This article presents an ac voltage controller that can operate under a wide range of loads, thanks to its high robustness to plant-model variations. A robust voltage controller is required in a droop-controlled inverter that operates connected to a grid or in island mode with other generators. In such modes of operation, the voltage source converter can experience large load-impedance variations depending on the number of parallel generators or the grid impedance value. Concerning the controller performance, the transient response is improved by selectively minimizing the output impedance of the system at the frequencies that typically contain the largest components of the output current. Complete harmonic control is achieved due to its zero output impedance at a set of design-selected frequencies. The proposed controller only measures the output voltage, and it contains a single-loop structure that uses all available bandwidth. In addition, a fast converter-current estimator provides protection against faults and inrush output currents. The design process only requires, as input parameters, the LC filter values, the sampling frequency, and a set of harmonics where load-current circulation is expected., European Commission | Ref. DPI2016-75832, Ministerio de Educación, Cultura y Deporte | Ref. FPU14/00683
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Grid-tied inverter with AC voltage sensorless synchronization and soft start

  • Pérez Estévez, Diego
  • Doval Gandoy, Jesús
This paper presents a novel grid synchronization method with bumpless start that requires minimal computational load and can selectively track the positive sequence of the grid voltage in an unbalanced and distorted three-phase weak grid. Only 12 floating-point operations are required to obtain the in-phase and quadrature components that define a synchronous frame which tracks the positive sequence of the grid voltage. Contrary to a phase-locked loop (PLL), the presented scheme does not require to measure any ac voltages. Therefore, this sensorless method is particularly suited for weak-grid conditions, in which the voltage at the point of common coupling may contain significant noise and can experience larger deviations from the grid voltage (compared to a strong grid) due to the voltage drop in the weak grid impedance. The error in the estimated phase depends on the accuracy of the plant model. If the LCL filter parameters are known, then both the proposal and a PLL-based scheme result in the same steady-state error. Experimental results show the advantages of the proposal compared to a moving average filter PLL., Agencia Estatal de Investigación | Ref. DPI2016-75832-R, Ministerio de Educación, Cultura y Deporte | Ref. FPU14/00683