Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Transient Analysis of Fresnel Zone Plates for Ultrasound Focusing Applications

  • Pérez-López, Sergio
  • Dolmatov, Dimitry O.
  • Tarrazó-Serrano, Daniel|||0000-0001-9986-0884
  • Rubio Michavila, Constanza|||0000-0002-4395-7473
  • Candelas Valiente, Pilar|||0000-0002-9924-7673
[EN] Fresnel Zone Plates are planar lenses that can be used to focus ultrasound beams. This kind of acoustic lenses can play a key role in the resolution of ultrasonic NDT systems. In this type of pulse-echo applications, the pulse duration is an important parameter that specifies the axial resolution, and thus, shorter ultrasound pulses provide higher resolutions. However, acoustic lenses exhibit a transient response that should be considered when setting the pulse duration, as pulses shorter than the transient state duration result in degradation in the response of acoustic lenses in terms of focal intensity, focal displacement, and lateral and axial resolutions. In this work, a thorough analysis of the transient response of Fresnel Zone Plates is discussed, demonstrating that the transient state should be considered in order to achieve optimal focusing performance. Theoretical and numerical results are presented, showing very good agreement., This work has been supported by Spanish MICINN RTI2018-100792-B-I00 project, Generalitat Valenciana AICO/2020/139 and the Russian Governmental program "Science" project FSWW-2020-0014. The research is carried out within the framework of Tomsk Polytechnic University Competitiveness Enhancement Program grant VIU-MNOL NK 187/2020. S.P.-L. acknowledges financial support from Universitat Politècnica de València grant program PAID-01-18. D.T.-S. acknowledges financial support from MICINN BES-2016-07713 project.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Application of Phase-Reversal Fresnel Zone Plates for High-Resolution Robotic Ultrasonic Non-Destructive Evaluation

  • Dolmatov, Dmitry O.
  • Filippov, German A.
  • Sednev, Dmitry A.
  • Tarrazó-Serrano, Daniel|||0000-0001-9986-0884
  • Uris Martínez, Antonio|||0000-0002-2005-2305
[EN] Nowadays the development of automated inspection systems based on six degrees of freedom robotic manipulators is a highly relevant topic in ultrasonic non-destructive testing. One of the issues associated with such development is the problem of acquiring high-resolution results. In this article, the application Phase-Reversal Fresnel Zone Plates is considered for solving this problem. Such acoustic lenses can solve the task of high-resolution results acquisition by using a single unfocused transducer. Furthermore, Phase-Reversal Fresnel Zone Plates can provide the desired focusing depth with the fixed thickness of the coupling layer. It is important in the case of application of devices which provide localized coupling. In this paper a proper design of Phase-Reversal Fresnel Zone Plate was determined according to the conditions of planned experiments. Its efficiency was verified via the Finite Element Method modeling. In all performed experiments the relative error of flaws size estimation did not exceed 6% whereas the signal-to-noise ratio was not lower than 17.1 dB. Thus, experimental results demonstrate that the application of Phase-Reversal Fresnel Zone Plates allowed to obtain results with high lateral resolution and signal-to-noise ratio. These results demonstrate the reasonability of the development of devices that provide localized coupling and use Phase-Reversal Fresnel Zone Plates., This work has been supported by Spanish Ministry of Science, Innovation and Universities (grant No. RTI2018-100792-B-I00) and Generalitat Valenciana AICO/2020/139 project. The study has been performed under the financial support by the Russian Ministry of Science and Higher Education within the State Task Research (basic fundamental) project # FSWW-2020-0014.