Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Heart Rate Variability and Exceptional Longevity

  • Hernández-Vicente, A.
  • Hernando, D.
  • Santos-Lozano, A.
  • Rodríguez-Romo, G.
  • Vicente-Rodríguez, G.
  • Pueyo, E.
  • Bailón, R.
  • Garatachea, N.
Centenarians are the paradigm of human extreme longevity and healthy aging, because they have postponed, if not avoided, mayor age-related diseases. The purpose of this study was to investigate potential differences in resting heart rate variability (HRV) between young adults, octogenarians, and centenarians and assess whether HRV variables are predictors of all-cause mortality in centenarians. To this end, three groups of participants: young adults (N = 20; 20.6 ± 2.3 years), octogenarians (N = 18; 84.1 ± 2.6 years), and centenarians (N = 17; 101.9 ± 1.9 years) were monitored for 15 min at rest (seated, without moving or talking) to measure RR intervals, from which HRV was evaluated. Our results showed a clear decrease with age in the main parasympathetic HRV variables, as well as in the standard deviation (SD) of the RR series [SD of normal-to-normal interval (SDNN)] and in low frequency (LF) heart rate (HR) oscillations, although differences between octogenarians and centenarians did not reach statistical significance. In 14 centenarians followed until death, only SDNN showed significant correlation (¿ = 0.536; p = 0.048) with survival prognosis. Additionally, SDNN <19 ms was associated with early mortality (=1 year) in centenarians (Hazard Ratio = 5.72). In conclusion, HRV indices reflecting parasympathetic outflow as well as SDNN and LF all present an age-related reduction, which could be representative of a natural exhaustion of allostatic systems related to age. Moreover, low SDNN values (<19 ms) could be associated with early mortality in centenarians. HRV seems to play a role in exceptional longevity, which could be accounted for by centenarians’ exposome.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Photoplethysmogram Signal Morphology-Based Stress Assessment

  • Rinkevicius, M.
  • Kontaxis, S.
  • Gil, E.
  • Bailon, R.
  • Lázaro, J.
  • Laguna, P.
  • Marozas, V.
Stress is a healthy natural response to a perceived or actual threat. However, when stress is persistent, it may decrease work productivity, increase the risk of diseases, and affect the quality of life. Stress is reflected in physiological variables, such as heart rate, blood pressure, and pulse wave velocity among others. A photoplethys-mogram (PPG) contains information related to pulse rate and blood pressure. This study analyses parameters derived from PPG signal morphology for mental stress assessment.A low-complexity algorithm is designed using bandpass filtered higher-order derivatives of the PPG signal for estimation of six morphological parameters: the forward pulse wave amplitude A1, the systole and diastole durations T1 and Td, the time delays of reflected waves T12 and T13 from the renal and iliac sites in the central arteries, and the pulse duration Tp. The parameters were investigated on a set of 18 healthy subjects by using a modified Trier Social Stress Test.The results show that the most sensitive PPG morphology parameters to mental stress are the amplitude of forward wave A1, the duration of diastole Td, the time delay of the reflected wave T13, and the pulse-to-pulse interval Tp.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Effect of the Heart Rate Variability Representations on the Quantification of the Cardiorespiratory Interactions during Autonomic Nervous System Blockade

  • Morales, J.F.
  • Bolea, J.
  • Van Huffel, S.
  • Bailón, R.
  • Varon, C.
The Heart Rate Variability (HRV) is a noninvasive tool to evaluate the activity of the autonomic nervous system. To study the HRV, different mathematical representations can be used. The selection of a representation might have an effect on the evaluation of the mechanisms that modulate the Heart Rate (HR). One of these mechanisms is the Respiratory Sinus Arrhythmia (RSA), i.e. an increased HR during inhalation and a decreased HR during exhalation. Different methods exist to quantify the RSA. A common approach is to calculate the power in the High Frequency (HF, 0.15 - 0.4 Hz) band of the spectrum of the HRV representation. More recently proposed methods use the respiratory signals to estimate the strength of the RSA.This paper studies the effect of the HRV representations on the quantification of the RSA. To this end, an experiment is used in which the sympathetic and parasympathetic branches of the autonomic nervous system are selectively blocked. Three different HRV representations are considered. Afterwards, the strength of the RSA is estimated using three approaches, namely the spectral content in the HF band of the HRV representations, orthogonal subspace projections and a time-frequency representation.The results suggest that the selection of an HRV representation does not have a significant impact on the RSA estimates in a healthy population.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Acute stress state classification based on electrodermal activity modeling

  • Greco, A.
  • Valenza, G.
  • Lázaro, J.
  • Garzón-Rey, J. M.
  • Aguiló, J.
  • De la Cámara, C.
  • Bailón, Raquel
  • Scilingo, Enzo Pascuale
Acute stress is a physiological condition that may induce several neural dysfunctions with a significant impact on life quality. Accordingly, it would be important to monitor stress in everyday life unobtrusively and inexpensively. In this paper, we presented a new methodological pipeline to recognize acute stress conditions using electrodermal activity (EDA) exclusively. Particularly, we combined a rigorous and robust model (cvxEDA) for EDA processing and decomposition, with an algorithm based on a support vector machine to classify the stress state at a single- subject level. Indeed, our method, based on a single sensor, is robust to noise, applies a rigorous phasic decomposition, and implements an unbiased multiclass classification. To this end, we analyzed the EDA of 65 volunteers subjected to different acute stress stimuli induced by a modified version of the Trier Social Stress Test. Our results show that stress is successfully detected with an average accuracy of 94.62%. Besides, we proposed a further 4-class pattern recognition system able to distinguish between non-stress condition and three different stressful stimuli achieving an average accuracy as high as 75.00%. These results, obtained under controlled conditions, are the first step towards applications in ecological scenarios.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Validity of the polar h7 heart rate sensor for heart rate variability analysis during exercise in different age, body composition and fitness level groups

  • Hernández-Vicente, A.
  • Hernando, D.
  • Marín-Puyalto, J.
  • Vicente-Rodríguez, G.
  • Garatachea, N.
  • Pueyo, E.
  • Bailón, R.
This work aims to validate the Polar H7 heart rate (HR) sensor for heart rate variability (HRV) analysis at rest and during various exercise intensities in a cohort of male volunteers with different age, body composition and fitness level. Cluster analysis was carried out to evaluate how these phenotypic characteristics influenced HR and HRV measurements. For this purpose, sixty-seven volunteers performed a test consisting of the following consecutive segments: sitting rest, three submaximal exercise intensities in cycle-ergometer and sitting recovery. The agreement between HRV indices derived from Polar H7 and a simultaneous electrocardiogram (ECG) was assessed using concordance correlation coefficient (CCC). The percentage of subjects not reaching excellent agreement (CCC > 0.90) was higher for high-frequency power (PHF) than for low-frequency power (PLF) of HRV and increased with exercise intensity. A cluster of unfit and not young volunteers with high trunk fat percentage showed the highest error in HRV indices. This study indicates that Polar H7 and ECG were interchangeable at rest. During exercise, HR and PLF showed excellent agreement between devices. However, during the highest exercise intensity, CCC for PHF was lower than 0.90 in as many as 60% of the volunteers. During recovery, HR but not HRV measurements were accurate. As a conclusion, phenotypic differences between subjects can represent one of the causes for disagreement between HR sensors and ECG devices, which should be considered specifically when using Polar H7 and, generally, in the validation of any HR sensor for HRV analysis.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Feasibility of atrial fibrillation detection from a novel wearable armband device

  • Bashar, Syed Khairul
  • Hossain, Md-Billal
  • Lázaro Plaza, Jesús
  • Ding, Eric Y.
  • Noh, Yeonsik
  • Cho, Chae Ho
  • McManus, David D.
  • Fitzgibbons, Timothy P.
  • Chon, Ki H.
Background Atrial fibrillation (AF) is the world’s most common heart rhythm disorder and even several minutes of AF episodes can contribute to risk for complications, including stroke. However, AF often goes undiagnosed owing to the fact that it can be paroxysmal, brief, and asymptomatic. Objective To facilitate better AF monitoring, we studied the feasibility of AF detection using a continuous electrocardiogram (ECG) signal recorded from a novel wearable armband device. Methods In our 2-step algorithm, we first calculate the R-R interval variability–based features to capture randomness that can indicate a segment of data possibly containing AF, and subsequently discriminate normal sinus rhythm from the possible AF episodes. Next, we use density Poincaré plot-derived image domain features along with a support vector machine to separate premature atrial/ventricular contraction episodes from any AF episodes. We trained and validated our model using the ECG data obtained from a subset of the MIMIC-III (Medical Information Mart for Intensive Care III) database containing 30 subjects. Results When we tested our model using the novel wearable armband ECG dataset containing 12 subjects, the proposed method achieved sensitivity, specificity, accuracy, and F1 score of 99.89%, 99.99%, 99.98%, and 0.9989, respectively. Moreover, when compared with several existing methods with the armband data, our proposed method outperformed the others, which shows its efficacy. Conclusion Our study suggests that the novel wearable armband device and our algorithm can be used as a potential tool for continuous AF monitoring with high accuracy.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Insertion of unsaturated C-C bonds into the O-H bond of an iridium(III)-hydroxo complex: Formation of phosphorescent emitters with an asymmetrical ß-diketonate ligand

  • Boudreault, P.L.T.
  • Esteruelas, M.A.
  • Lopez, A.M.
  • Oñate, E.
  • Raga, E.
  • Tsai, J.Y.
A synthetic methodology to prepare iridium(III) emitters of the class [3b+3b+3b'] with two ortho-metalated 1-phenylisoquinolines and an asymmetrical ß-diketonate has been discovered. The abstraction of the chloride ligands of the dimer [Ir(µ-Cl){¿2-C, N-(C6H4-isoqui)}2]2 (1, C6H5-isoqui = 1-phenyl-isoquinoline) with AgBF4 in acetone and the subsequent addition of water to the resulting solution affords the water solvate mononuclear complex [Ir{¿2-C, N-(C6H4-isoqui)}2(H2O)2]BF4 (2), which reacts with KOH to give the dihydroxo-bridged dimer [Ir(µ-OH){¿2-C, N(C6H4-isoqui)}2]2 (3). Treatment of the latter with dimethyl acetylenedicarboxylate leads to Ir{¿2-C, N-(C6H4-isoqui)}2{¿2-O, O[OC(CO2CH3)CHC(OCH3)O]} (4), as a result of the anti-addition of the O-H bond of a mononuclear [Ir(OH){¿2-C, N(C6H4-isoqui)}2] fragment to the C-C triple bond of the alkyne and the coordination of one of the carboxylate substituents to the metal center. Complex 3 also reacts with a, ß-unsaturated ketones. The reaction with 3-(4-methylphenyl)-1-phenylprop-2-en-1-one affords Ir{¿2-C, N-(C6H4-isoqui)}2{¿2-O, O-[OC(C6H5)CHC(p-C6H4Me)O]} (5), whereas methyl vinyl ketone gives a mixture of Ir{¿2-C, N-(C6H4-isoqui)}2{¿2-O, O-[OC(CH3)CHCHO]} (6) and Ir{¿2-C, N-(C6H4-isoqui)}2{¿2-O, O-[OC(CH3)CHC(CH= CH2)O]} (7). Complexes 5 and 6 are the result of the addition of the O-H bond of the mononuclear [Ir(OH){¿2-C, N-(C6H4isoqui)}2] fragment to the C-C double bond of the a, ß-unsaturated ketones and the coordination of the carbonyl group to the iridium center, to generate O, O-chelates which lose molecular hydrogen to aromatize into the asymmetrical ß-diketonate ligands. Complexes 4-7 are phosphorescent emitters in the red spectral region (599-672 nm) in doped poly(methyl methacrylate) (PMMA) film at 5 wt % at room temperature and 2-methyltetrahydrofuran at room temperature and 77 K. They display short lifetimes (0.8-2.5 µs) and quantum yields in both doped PMMA films and in 2-methyltetrahydrofuran at room temperature depending on the substituents of the ß-diketonate: about 0.6-0.5 for 4 and 6 and ca. 0.35 for 5 and 7.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Estimation of the second ventilatory threshold through ventricular repolarization profile analysis

  • Milagro, J.
  • Hernández-Vicente, A.
  • Hernando, D.
  • Casajús, J.A.
  • Garatachea, N.
  • Bailón, R.
  • Pueyo, E.
Under the hypothesis that sympathetic control of ventricular repolarization may change once the second ventilatory threshold (VT2) has been reached, a novel methodology for non-invasive VT2 estimation based on the analysis of the T wave from the electrocardiogram (ECG) is proposed, and potential underlying physiological mechanisms are suggested. 25 volunteers (33.4 ± 5.2 years) underwent an incremental power cycle ergometer test (25 W/minute). During the test, respiratory gas exchange and multi-lead ECG were acquired. The former was employed to determine VT2, used here as a reference, whereas the latter was used to compute the temporal profiles of an index of ventricular repolarization instability (dT) and its low-frequency (LF) oscillations (LFdT). The sudden increases observed in dT and LFdT profiles above an established heart rate threshold were employed to derive VT2 estimates, referred to as VT2dT and VT2LFdT, respectively. Estimation errors of -4.7 ± 25.2 W were obtained when considering VT2dT. Errors were lower than the one-minute power increment of 25 W in 68% of the subjects and lower than 50 W in 89.5% of them. When using VT2LFdT, estimation error was of 15.3 ± 32.4 W. Most of the subjects shared common characteristic dT and LFdT profiles, which could be reflecting changes in the autonomic control of ventricular repolarization before and after reaching VT2. The analysis of ventricular repolarization dynamics during exercise allows non-invasive ECG-based estimation of VT2, possibly in relation to changes in the autonomic control of ventricular electrical activity when VT2 is reached.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Blunted autonomic reactivity to mental stress in depression quantified by nonlinear cardiorespiratory coupling indices

  • Kontaxis, Spyridon
  • Laguna, Pablo
  • García Pages, Esther
  • Posadas-de Miguel, Mar
  • Siddi, Sara
  • Luisa Bernal, Maria
  • Maria Haro, Josep
  • Aguiló, Jordi
  • de la Camara, Concepción
  • Bailón, Raquel
  • Gil, Eduardo
In this study, differences in autonomic reactivity to mental stress between Major Depressive Disorder (MDD) patients and healthy control (HC) subjects are assessed by nonlinear cardiorespiratory coupling indices derived from the Real Wavelet Biphase. The degree and strength of Quadratic Phase Coupling (QPC) between interacting oscillations of Heart Rate Variability (HRV) and respiration are quantified before, during and after the execution of acognitive task. Results show that the QPC strength and QPC degree between the respiration and the respiratory sinus arrhythmia component of HRV were lower in HC compared to MDD during stress, suggesting that the parasympathetic branch was less inhibited in MDD patients. During recovery, only in HC group, this degree of QPC increased, while the respiratory rate was reduced, compared to the basal stage. The degree of QPC between the respiration and components of HRV in the low frequency band ([0.04, 0.15] Hz) increased in HC during stress, compared to the basal stage, while remained unchanged in MDD patients. These results imply that depression is associated with blunted autonomic reactivity to mental stress