Skip to main content

BATERIAS DE ESTADO SOLIDO DE ARQUITECTURA PLANA

PCIN-2017-110

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos Programación Conjunta Internacional
Call year 2017
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Preparation and Characterization of Large Area Li-NASICON Electrolyte Thick Films

  • Jiménez, Ricardo
  • Sobrados, Isabel
  • Martínez-Chaparro, Sandra
  • Campo, Ángel Adolfo del
  • Calzada, M. L.
  • Sanz Lázaro, Jesús
  • Tsai, Shu Yi
  • Lin, Ming Rui
  • Fung, Kuan Zong
  • Kazakevicius, Edvardas
  • Kežionis, Algimantas
The preparation of solid electrolyte ceramic membranes is the object of intense study for its fundamental parts in the development of all solid-state batteries and improved battery separators. In this work, the procurement of large area solid electrolyte ceramic thick film membranes of the Li-NASICON Li1.3Al0.3Ti1.7(PO4)3 (LATP) composition is attempted. Through the use of LATP powders from a sol–gel reaction, a slurry is formulated and tape casted. The green tapes are sintered using two sintering times. In both cases, ceramic thick films of a 5.5 × 5.5 cm2 area and ≈250 µm average thickness were obtained. The characterization indicated almost pure phase samples with a bi-modal microstructure composed of large and smaller grains, being larger for longer sintering time. The samples are porous and brittle, presenting very high “bulk” conductivity but lower total direct current (DC) one, as compared with the commercial Li-NASICON (OHARA) thick films with a similar area. The larger the grains, the poorer the total conductivity and the mechanical properties of the thick-films. The formation of poorly adhering grain boundaries as the grain size grows is responsible for the worsened properties. A better control of the microstructure is mandatory., This research was funded by the Spanish Ministry of Science, Innovation, and Universities, PCIN-2017-110, in the frame of the M-Era-net 2016 program, by a grant (S-M-ERA.NET-17-1) from the Research Council of Lithuania, and by the project MOST 106-2923-M-006-002-MY3. Project MAT2016-78362-C4-2R is also acknowledged., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Li conductivity in Li1+xTi2-xAlx(PO4)3 (0.3≤ x≤ 0.7) ceramics prepared from sol-gel precursors

  • Jiménez, Ricardo
  • Sobrados, Isabel
  • Martínez-Chaparro, Sandra
  • Criado Sanz, María
  • Perea, Gracia Belén
  • Sanz, Jesús
LiTiAl (PO) (LTAP) x = 0.3, 0.4, 0.5 and 0.7) compounds, prepared at 800 °C by sol-gel, have been studied by X-ray diffraction, Nuclear Magnetic Resonance, Scanning Electron Microscopy and Impedance Spectroscopy. The increment of lithium enhances Li–Li repulsions, favoring the creation of vacancies at the conduction paths intersection (M1 sites), increasing Li mobility along (… M1-M2-M1 …) channels in NASICON phases. The partial elimination of segregated AlPO, LiAlPO and LiTiPO phases increased Ti, Al solubility in NASICON, improving overall conductivity in ceramics prepared at 950 °C. The maximum of “bulk” conductivity was produced in x = 0.4 sample, as a consequence of the creation of M1 vacancies and allocation of Li in M2 cavities with optimal Li/vacancy distribution. The presence of secondary phases increased grain boundary impedance, shifting maximum of overall conductivity to x = 0.3 compound. Obtained results are compared with those reported previously in LTPA samples prepared by the ceramic route., This research was funded by Regional and National agencies for financial support: S2013/MIT-2753 project (Comunidad de Madrid), MAT2016-78362-C4-2R and PCIN-2017-110 (M-ERA-net 2016) projects (Education Ministry)
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Otros (Other)

Project: Planar architecture all solid state batteries. PLARASBAT Project ID:4023. Data Management Plan v 1.0

  • PLARASBAT Project ID:4023
  • Jiménez, Ricardo
[EN] The project “Planar architecture all solid state batteries” (PLARASBAT) has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement no 4023. The project involves the research in the properties of solid electroactive materials and interfaces. For the development of a reliable all solid state battery (ASSB), the knowledge of the properties (electrical, structural, micro-structural) of the different components (electrodes, electrolytes, interfaces electrode / electrolyte) of the battery must be known. As the way of preparing an ASSB is different to that of the conventional batteries using liquid electrolytes, there are many information about the intrinsic properties of the components in ceramic form that is not available as this components were used in powder form in the conventional batteries. Besides the formation of the electrode/electrolyte interface should be done using relative high temperatures, and so the stability of the components in order to produce a clean electrochemically active interface is challenging. During the development of the project many electrodes, electrolytes and interfaces will be characterized and most of the results will be published, but the large amount of data produced can be collected and order to be accessible to the scientific community. The project will generate data on structural (DRX), electrical, MNR and micro-structural characterization. The formats can be graphics plots, raw data files and figures. Re-using of existing data is not planned, most probably existing data will be used as hints for the properties of solid electroactive materials and interfaces. For example: https://materialsproject.org/ The data will be produced by the different groups in the consortium, that have an specific role, related to their expertise. Data are in the order of magnitude of 500 MB – 1GB. The data generated and collected during the development of the "PLARASBAT" project, can be useful for scientist working in the preparation of Li conducting solid electrolytes as well as in the preparation and characterization of anodes and cathodes for Li secondary batteries. It is important to stress that the data generated in the characterization of solid electrolyte / electrode interfaces are very interesting for the development of reliable ASSBs., PLARASBAT) has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement no 4023. Spanish National Research Agency (PCIN-2017-110), No
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication Artículo científico (JournalArticle)

Enhanced “overall” ionic conductivity in Li1+xAlxTi2−x(PO4)3 (0.3 ≤ x ≤ 0.7) ceramics prepared from sol-gel powders by spark plasma sintering

  • Martínez-Chaparro, Sandra
  • Kobylianska, Sofia D.
  • Sobrados, Isabel
  • Jiménez, Ricardo
  • Sanz, Jesús M.
The Li1+xAlxTi2−x(PO4)3 (LATPx) series displays the highest “bulk” reported conductivity, but a much lower “overall” contribution, that changes with the powder preparation and sintering conditions. In this work, the preparation of LATPx ceramics is discussed, by using the sol-gel technique for powders synthesis and mild spark plasma (SPS) for ceramics sintering at 800 °C. An “overall” conductivity ~ 2.10−3 Ω−1 cm−1 was obtained for the x = 0.4 composition, that was the result of a high “bulk” conductivity, an optimized microstructure and almost full density, in absence of micro-cracks, with a small content of secondary phases and clean grain boundaries. Fast-ion ceramics prepared by SPS are good candidates for solid electrolytes in all solid state batteries (ASSB)., This research was funded by Regional and National agencies: S2013/MIT-2753 project (Comunidad de Madrid), MAT2016-78362-C4-2R, PCIN-2017-110 (M-ERA-net 2016) and PID2019-106662RB-C42 projects (Education Ministry)., Peer reviewed
UPCommons. Portal del coneixement obert de la UPC
Publication Artículo científico (JournalArticle)

Permutation entropy analysis of EEG signals for distinguishing eyes-open and eyes-closed brain states: Comparison of different approaches

  • Gancio Vázquez, Juan|||0000-0002-0673-174X
  • Masoller Alonso, Cristina|||0000-0003-0768-2019
  • Tirabassi, Giulio|||0000-0002-8028-9005
Developing reliable methodologies to decode brain state information from electroencephalogram (EEG) signals is an open challenge, crucial to implementing EEG-based brain–computer interfaces (BCIs). For example, signal processing methods that identify brain states could allow motor-impaired patients to communicate via non-invasive, EEG-based BCIs. In this work, we focus on the problem of distinguishing between the states of eyes closed (EC) and eyes open (EO), employing quantities based on permutation entropy (PE). An advantage of PE analysis is that it uses symbols (ordinal patterns) defined by the ordering of the data points (disregarding the actual values), hence providing robustness to noise and outliers due to motion artifacts. However, we show that for the analysis of multichannel EEG recordings, the performance of PE in discriminating the EO and EC states depends on the symbols’ definition and how their probabilities are estimated. Here, we study the performance of PE-based features for EC/EO state classification in a dataset of subjects with one-minute 64-channel EEG recordings in each state. We analyze features obtained from patterns encoding temporal or spatial information, and we compare different approaches to estimate their probabilities (by averaging over time, over channels, or by “pooling”). We find that some PE-based features provide about 75% classification accuracy, comparable to the performance of features extracted with other statistical analysis techniques. Our work highlights the limitations of PE methods in distinguishing the eyes’ state, but, at the same time, it points to the possibility that subject-specific training could overcome these limitations., We acknowledge the support of ICREA ACADEMIA,AGAUR (2021 SGR 00606 and FI scholarship) and Ministerio de Ciencia e Innovación (Project No. PID2021-123994NB-C21), Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Permutation entropy analysis of EEG signals for distinguishing eyes-open and eyes-closed brain states: Comparison of different approaches

  • Gancio Vázquez, Juan
  • Masoller Alonso, Cristina
  • Tirabassi, Giulio
Developing reliable methodologies to decode brain state information from electroencephalogram (EEG) signals is an open challenge, crucial to implementing EEG-based brain–computer interfaces (BCIs). For example, signal processing methods that identify brain states could allow motor-impaired patients to communicate via non-invasive, EEG-based BCIs. In this work, we focus on the problem of distinguishing between the states of eyes closed (EC) and eyes open (EO), employing quantities based on permutation entropy (PE). An advantage of PE analysis is that it uses symbols (ordinal patterns) defined by the ordering of the data points (disregarding the actual values), hence providing robustness to noise and outliers due to motion artifacts. However, we show that for the analysis of multichannel EEG recordings, the performance of PE in discriminating the EO and EC states depends on the symbols’ definition and how their probabilities are estimated. Here, we study the performance of PE-based features for EC/EO state classification in a dataset of subjects with one-minute 64-channel EEG recordings in each state. We analyze features obtained from patterns encoding temporal or spatial information, and we compare different approaches to estimate their probabilities (by averaging over time, over channels, or by “pooling”). We find that some PE-based features provide about 75% classification accuracy, comparable to the performance of features extracted with other statistical analysis techniques. Our work highlights the limitations of PE methods in distinguishing the eyes’ state, but, at the same time, it points to the possibility that subject-specific training could overcome these limitations., We acknowledge the support of ICREA ACADEMIA,AGAUR (2021 SGR 00606 and FI scholarship) and Ministerio de Ciencia e Innovación (Project No. PID2021-123994NB-C21), Peer Reviewed, Objectius de Desenvolupament Sostenible::3 - Salut i Benestar, Postprint (published version)