Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Visco-hyperelastic material model fitting to experimental stress-strain curves using a genetic algorithm and its application to soft tissue simulants

  • Gómez-Garraza, Samuel
  • de Santos, Raúl
  • Marco, Miguel
  • Infante-García, Diego|||0000-0001-6010-2031
[EN] Ballistic impacts on human thorax without penetration can produce severe injuries or even death of the carrier. Soft tissue finite element models must capture the non-linear elasticity and strain-rate dependence to accurately estimate the dynamic human mechanical response. The objective of this work is the calibration of a visco-hyperelastic model for soft tissue simulants. Material model parameters have been calculated by fitting experimental stress-strain relations obtained from the literature using genetic algorithms. Several parametric analyses have been carried out during the definition of the optimization algorithm. In this way, we were able to study different optimization strategies to improve the convergence and accuracy of the final result. Finally, the genetic algorithm has been applied to calibrate two different soft tissue simulants: ballistic gelatin and styrene-ethylene-butylene-styrene. The algorithm is able to calculate the constants for visco-hyperelastic constitutive equations with high accuracy. Regarding synthetic stress-strain curves, a short computational time has been shown when using the semi-free strategy, leading to high precision results in stress-strain curves. The algorithm developed in this work, whose code is included as supplementary material for the reader use, can be applied to calibrate visco-hyperelastic parameters from stress-strain relations under different strain rates. The semi-free relaxation time strategy has shown to obtain more accurate results and shorter convergence times than the other strategies studied. It has been also shown that the understanding of the constitutive models and the complexity of the stress-strain objective curves is crucial for the accuracy of the method., This work was supported by the Madrid Community (Spain) (IND2020/IND-17413); Generalitat Valenciana and European Social Fund (CIAPOS/2021/271); and Universitat Politecnica de Valencia (PAID-PD-22); MCIN/AEI/https://doi.org/10.13039/501100011033 and the European Union "NextGenerationEU"/PRTR" (PID2020-118480RB-C21, PDC2021-121368-C22). The authors also acknowledge to the Ministry of Culture and Sport (Spain) and European Union-Next Generation EU, the financial support through the project "Gemelos digitales para el diseno biomecanico avanzado de protecciones de cabeza en deportes con riesgo de impacto" (EXP_75127, Universidad Carlos III de Madrid). DAS:The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Estimation of the in-plane ultimate stress of lamellar tissue as a function of bone mineral density and osteocyte lacunae porosity

  • Vercher Martínez, Ana|||0000-0003-3695-6461
  • Megías-Díaz, Raquel|||0000-0002-1698-7108
  • Belda Ricardo|||0000-0003-3913-5773
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Vargas, Pablo
[EN] Detailed finite element models based on medical images (𝜇-CT) are commonly used to analyze the mechanical behavior of bone at microscale. In order to simulate the tissue failure onset, isotropic failure criteria of lamellar tissue are often used, despite its non-isotropic and heterogeneous nature. The main goal of the present work is to estimate the in-plane ultimate stress of lamellar bone, considering the influence of mineral content and the porosity due to the osteocyte lacunae concentration. To this aim, a representative volume cell of lamellar tissue is modeled numerically, including: (1) non-isotropic elastic properties of tissue as a function of the bone mineral density and (2) explicit modeling of the osteocyte lacunae, considering the range of porosity content, size and orientation of ellipsoid-shaped lacunae. Firstly, the element size for the finite element models have been defined from a preliminary convergence analysis. Bounds on the ultimate stress of non-porous lamellar tissue are estimated for two values of bone mineral density, considering the results of tensile and compressive tests of wet osteons from the literature. Subsequently, the ultimate stress of lamellar tissue considering several values of micro-porosity is addressed. Results: Results obtained in this work show that the strength of lamellar bone decreases exponentially with the increase of lacunae porosity concentration. Ultimate stress of non-porous tissue (𝑝 = 0%) increases with high mineral content, reaching a value of ̄ 𝑆 𝑐 𝑡𝑟𝑎𝑛𝑠 = 355.40 ± 39.80 MPa for compression in the transversal direction of the fiber bundles, being BMD = 1.246 g/cm3. The mean value for the longitudinal to transverse strength ratio evaluated for porosity 𝑝 = 0%, 1% and 5% and a mineral content BMD = 1.2 g/cm3, is 2.47:1 for tension and 1.55:1 for compression. These values are in agreement with literature. Conclusions: Osteocyte lacunae act as stress concentrators, acting as potential stimulus for the bone regeneration process. A novel micromechanical model for the in-plane ultimate stress of lamellar tissue as a function of mineral content and lacunae concentration is presented. Additional considerations about the intralamellar shear stress evolution are also given, The authors acknowledge the Ministerio de Ciencia e Innovación y Universidades and the European Regional Development Fund (FEDER) for the financial support received through the projects PID2020- 118920RB-I00 and PID2020-118480RB-C21 and C22 funded by MCIN/AEI/10.13039/501100011033 and by ERDF A way of making Europe , the Ministerio de Ciencia e Innovación y Universidades MCIN/AEI/ 10.13039/501100011033 and Europe Union NextGenerationEU/PRTR for the projects PDC2021-121368-C21 and C22, and the Generalitat Valenciana for Programa PROMETEO/2021/046
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The role of the interfaces and cross-links on the mechanical behavior of mineralized collagen fibrils. A numerical approach

  • Vercher Martínez, Ana|||0000-0003-3695-6461
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Fuenmayor Fernández, Francisco-Javier|||0000-0003-3594-9593
  • García-Aznar, J. Manuel
[EN] Mechanical properties of bone tissue are highly dependent on its hierarchical structure. The presence of microcracks and diffuse damage in lamellar bone is correlated with the failure of the collagen-mineral interface in mineralized collagen fibrils (MCF). The main goal of this work is to evaluate the mechanical behavior of the interfaces and quantify the stiffness loss of the MCF associated with different failure mechanisms, under controlled in-plane displacement. Additionally, we aim to study the role of the cross-links on the fibril mechanical response, beyond the interface failure. Inter- and intra-microfibrilar cross-links are analyzed. In order to address the first issue, a detailed representative volume of the MCF is analyzed by means of the finite element method, under the assumption of plane strain and periodic boundary conditions. In this model the interfaces between constituents are modeled with an exponential cohesive law. Enzymatic cross-links, located at the molecular terminals connecting each 4D (D = 67 nm) staggered molecules, are represented by non-linear springs. Three in-plane controlled deformations are applied. The results of this work provide the anisotropic stiffness loss of the tissue involved in the different failure mechanisms at the nano-scale length. The initiation of microcracks and the presence of damage zones are compatible with the failure mechanisms observed at interfaces. Interface failure entails a progressive stiffness loss, bringing a non-linear behavior of bone. The strength obtained for the longitudinal maximum deformation is more than 20 times the transverse strength and 3.5 times the shear strength. The quantification of the reduction percentage in the elastic moduli and the shear stiffness when the fibril is damaged, has a potential application in improving failure criteria based on degradation of elastic constants. When longitudinal elongation is applied, the mechanical contribution of the cross-links in delaying the failure initiation of the interface is shown. Likewise, results of this work confirm the scarce influence of the cross-links in the strain range analyzed. Additionally, a threedimensional numerical model of several microfibrils is defined with the aim of analyzing the mechanical relevance of inter- and intra-microfibrilar cross-links, beyond the interface failure. Results confirm that cross-links transfer the load when strain increases, being highlighted the mechanical competence of the trivalent cross-links., The authors acknowledge the Ministerio de Ciencia e Innovacion y Universidades and the European Regional Development Fund (FEDER) for the financial support received through the projects PID2020-118920RB-I00, PID2020-118480RB-C21 and C22 funded by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe", the Ministerio de Ciencia e Innovacion y Universidades MCIN/AEI/10.13039/501100011033 and Europe Union Next Generation EU/PRTR for the projects PDC2021-121368-C21 and C22, CRUE-Universitat Politecnica de Valencia and the Generalitat Valenciana for Programa PROMETEO/2021/046.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Influencia de la morfometría y las propiedades aparentes en la integridad estructural del hueso trabecular humano enfermo y sano

  • Megías-Díaz, Raquel|||0000-0002-1698-7108
  • Belda Ricardo|||0000-0003-3913-5773
  • Vercher Martínez, Ana|||0000-0003-3695-6461
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
[ES] En este trabajo, se han estudiado las relaciones entre la morfometría y la respuesta mecánica de hueso trabecular humano. Las muestras analizadas proceden de cabezas femorales humanas y están divididas en tres grupos: grupo sano (GS), grupo artrósico (GA) y grupo osteoporótico (GO). Las muestras se han escaneado mediante micro-CT para disponer de la geometría y poder realizar el estudio morfométrico de la microarquitectura trabecular. Se han llevado a cabo ensayos de compresión cuasiestática en la dirección más rígida de las muestras hasta producir su fractura. La influencia entre los parámetros se ha estudiado mediante correlaciones lineales por grupos de forma independiente, ya que el comportamiento aparente es tan diferente entre las muestras que las relaciones obtenidas analizando todas las muestras en conjunto no son relevantes y presentan unos coeficientes de correlación muy bajos. El grupo sano (GS) es el que presenta relaciones relevantes (con un p-valor < 0.05) con la densidad de conectividad Conn.D, el número de trabéculas Tb.N, el área superficial de hueso BS y la dimensión fractal D. Además, también se han relacionado los parámetros aparentes obtenidos de los ensayos experimentales entre sí. Para el caso de GS, presenta correlación entre la tensión de fallo final ¿¿ y el módulo de Young aparente ¿¿¿¿. Respecto al grupo osteoporótico, tanto ¿¿ como ¿¿¿¿ presentan correlaciones con la separación trabecular Tb.Sp y el número de trabéculas Tb.N. Además, también presentan correlación ¿¿¿¿ y la deformación asociada a la que se da la tensión de fallo final ¿¿. El grupo artrósico (GA) es el que menos correlaciones presenta, únicamente entre ¿¿ y el volumen total de las muestras TV y entre ¿¿ y ¿¿¿¿. Las correlaciones lineales obtenidas indican que se podría determinar el módulo de Young aparente o la tensión máxima que soportan las muestras sin realizar los ensayos experimentales mediante la evaluación de imágenes micro-CT., Los autores desean agradecer la financiación recibidadesde la GVA por el programa PROMETEO 2021/046, y por los proyectos PID2020-118920RB-I00 y PID2020-118480RB-C21 y C22, financiado por MCIN/AEI/10.13039/5011000110 33 y por FEDER Una manera de hacer Europa y el proyecto PDC2021- 121368-C21 y C22 financiado por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Influence of material extrusion parameters on fracture mechanisms of polylactic acid under three-point bending

  • Álvarez-Blanco, Mario
  • Arias-Blanco, Adrián
  • Marco, Miguel
  • Miguélez, María Henar
  • Infante-García, Diego|||0000-0001-6010-2031
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
[EN] In this work, a thorough fracture assessment of additive manufactured specimens made by 3D printed polylactic acid (PLA) under three-point bending is presented. This polymer is widely used in additive manufacturing for numerous applications, gaining prominence in fields such as biomechanics. Prismatic fully dense specimens and lattice structure specimens with different raster orientations and densities were fabricated using the material extrusion-based additive manufacturing technique. The objective is to analyse the effect of relevant process parameters on the fracture mechanism of short beam specimens tested under three-point bending. Digital image correlation and computed tomography have been used to measure the full field displacement and internal defects, respectively. Furthermore, the theory of critical distances was applied to assess the mechanical strength of lattice structure specimens. The results have shown the strong influence of raster orientation on the mechanical strength and fracture patterns even for negative air gap values. The transition from brittle to ductile failure was observed when changing density and raster orientation. Lastly, neck-shaped defects were detected in knots of specimens manufactured with a grid pattern. Defects in grid pattern specimens appear due to the prescribed path followed by the extruder during the building process. They were the main source causing a decrease in the mechanical strength and fracture trajectories. The objective of this research is to enhance the knowledge on the mechanical response of 3D printed components and to give an in-depth failure assessment., The authors gratefully acknowledge the funding support received from the Spanish Ministerio de Ciencia e Innovacion for funding the projects PID2020-112628RA-I00 and PID2020-118480RB-C21, -C22, MCIN/AEI / 10.13039/501100011033 and by "ERDF A way of making Europe"; project PDC2021-121368-C21 and C22 funded by MCIN/AEI/ 10.13039/501100011033 and by the "European Union NextGenerationEU/PRTR". The authors also thank the funding received from Madrid Community (Spain) through the project IND2020/IND-17413. The financial support of Generalitat Valenciana and European Social Fund through Programme PROMETEO 2021/046 and CIAPOS/2021/271 is also acknowledged. Lastly, the Universitat Politecnica de Valencia is acknowledged for the financial support through PAID-PD-22.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental and numerical analysis of the influence of intramedullary nail position on the cut-out phenomenon

  • Arias-Blanco, A.
  • Marco, M.
  • Larraínzar-Garijo, R.
  • Miguélez, M. H.
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
[EN] Background and objective: Proximal femur fractures, colloquially known as hip fractures, are a common pathology with increasing incidence in the last years due to the enhanced ageing population. Regarding the extracapsular fracture, the treatment for this pathology consists of a fixation of the fragments using an osteosynthesis device, mainly the intramedullary nail. This repairing method implies several complications, which may include the failure of the fixation device, frequently occurring due to the "cut-out" mechanism. The present work focuses on the study of how the position of the cephalic screw, which should be fixed during surgery, affects the cut-out risk. Through experimental tests and numerical models some variables that can be critical for the cut-out phenomenon are analysed. Methods: This study has been carried out through a numerical model based on the finite element method and experimental tests. The digital image correlation technique has been used in experimental tests to measure displacements on the femoral surface with the objective of numerical model validation. Some basic daily activities with different intramedullary nail positions have been analysed through the numerical model, considering variables that can induce the cut-out complication. Results: The results show how the intramedullary nail position clearly influences the cut-out risk, showing that displacements in the upper, anterior and posterior direction increase the cut-out risk, while displacement in the lower direction endangers the intramedullary nail itself. Thus, the centred position is the one which reduces the cut-out risk. Conclusions: This work supposes an improvement in the knowledge of the cut-out phenomenon thanks to the combination of experimental testing and validated numerical models. The effects of different intramedullary nail positions in the femoral head are studied, including a novelty variable as torque, which is critical for the structural integrity of the fixation. The main conclusion of the work is the determination of the central intramedullary nail position as the most favourable one for decreasing the cut-out risk., The authors gratefully acknowledge the funding support received from the Spanish Ministry of Science and Innovation for funding project PID2020-112628RA-I00/AEI/10.13039/501100011033, projects PID2020-118480RB-C21 and -C22 and from the Madrid Community (Spain) through the project IND2020/IND-17413. The financial support of the European Union NextGenerationEU/PRTR through grant number PDC2021-121368-C21 and -C22 and the Generalitat Valenciana through Programme PROMETEO 2021/046 is also acknowledged.& nbsp;
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Damage mechanism identification in additive manufactured extruded polymer via acoustic emission technique, experimental testing and pattern recognition models

  • Barriga-Machado, Byron|||0000-0003-4522-3833
  • Infante-García, Diego|||0000-0001-6010-2031
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Hernández-Casamayor, Álvaro
[EN] This work presents a novel framework for identifying damage mechanisms in material extrusion-based additive manufacturing parts, combining acoustic emission (AE) analysis with unsupervised and hybrid supervised learning techniques. The main objective is to characterize failure modes in polylactic acid specimens and demonstrate the practical potential of data-driven AE analysis for early damage detection and quantification in polymeric additive manufacturing. Extending the current state of the art, the novelty of this study lies in the exploration of multiple clustering algorithms through two approaches: (i) unsupervised learning comparing k-means and density-based spatial clustering of noise-based applications (DBSCAN) combined with fast Fourier transform (FFT) for feature extraction and (ii) a hybrid supervised deep learning approach using a convolutional neural network (CNN) trained on spectrograms from the continuous wavelet transform (CWT). While these approaches have been applied in fields such as composite materials, this is the first work to transfer and validate their use in extrusion-based polymer specimens. The experimental campaign based on different stack configurations of additive extruded samples provides ground-truth fracture observations for model assessment. As a result, DBSCAN proved to be effective in the classification process, identifying two distinct clusters: one with relatively low frequencies up to 260 kHz and another with high frequencies between 270 and 390 kHz. The correlations between these groups and the failure mechanisms were established by visually inspecting the fractured specimens. On the other hand, the hybrid approach combined the labels obtained from the DBSCAN model and the time-frequency features extracted from the signal spectrograms, achieving results consistent with the unsupervised approach. Finally, after enhancing the model performance through successive revisions via experimental correlation of different data-driven analysis pipelines, the present research offers a practical, rapid, and non-destructive tool for in-situ damage detection in polymeric additive manufacturing, contributing to structural health monitoring and process optimization., This research is part of the R+D+i project PID2023-151610OB-C22, funded by MCIN/AEI, Spain/10.13039/501100011033 and by "ERDF: A way of making Europe", and grant PDC2021-121368-C22 funded by MCIN/AEI/10.13039/501100011033 and by the "European Union NextGenerationEU/PRTR". The funding of the Generalitat Valenciana, Programme PROMETEO, Spain 2021/046 is also acknowledged. The authors also acknowledge the funding received by Universitat Politecnica de Valencia, Spain and CRUE through Programa de Ayudas de Investigacion y Desarrollo (PAID-01-23) and funding for open access.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental and numerical analyses of the interaction between rigid non-penetrating projectiles, soft and hard tissue simulants and composite ballistic protection

  • Gómez-Garraza, Samuel
  • Álvarez-Blanco, Mario
  • Miguélez, Beatriz
  • Loya, José Antonio
  • Marco, Miguel
  • Infante-García, Diego|||0000-0001-6010-2031
[EN] The study of ballistic personal protections often only focuses on the mechanical response and ballistic limits of the armor considered. However, understanding the armor-carrier interaction under dynamic conditions remains underexplored. This research analyzes non-penetrating ballistic impacts on gelatin samples involving multi-ply composite ballistic protection panels, focusing on biomechanical damage. For this purpose, ballistic gelatin is presented as a reliable soft tissue simulant and thoroughly examined under non-penetrating ballistic impact conditions. The methodology includes two experimental approaches: (1) lowvelocity impact tests using rigid projectiles to isolate gelatin's mechanical behavior and (2) high-velocity impact tests with steel spherical projectiles, involving additionally ballistic protection panels and a simplified bone surrogate as a hard tissue simulant. Due to the complexity of experimentally assessing the dynamic interaction between soft and hard tissue simulants, protection, and projectiles, an explicit finite element model has been developed. These simulations incorporate different damage models in composite protection and bone surrogate to accurately replicate the experimental tests. In addition, a proposed visco-hyperelastic constitutive model for ballistic gelatin is validated, generating a powerful predictive tool for evaluating ballistic protection and biomechanical damage. This work provides a comprehensive study of the behind armor blunt trauma and introduces an experimental methodology to quantify the mechanical response of ballistic gelatin and hard tissue simulants under nonpenetrating ballistic impacts. It addresses a key gap in modeling soft tissue simulants under high-energy conditions and validates the corresponding visco-hyperelastic constitutive model. Findings highlight the importance of considering hard tissue effects when evaluating composite protection performance, which has not been previously addressed in literature. This work proposes an alternative evaluation framework to the assessment of advanced armor and biomechanical phenomena estimation. We further provide a deeper biomechanical insight in comparison with existing standards, bridging the gap between multi-layered composite protection and the human biomechanical response., This work was supported by the Madrid Community, Spain [IND2020/IND-17413]; the Spanish Ministry of Culture and Sport and "European Union NextGenerationEU/PRTR" ["Gemelos digitales para el diseno biomecanico avanzado de protecciones de cabeza en deportes con riesgo de impacto" EXP_75127, Universidad Carlos III de Madrid]; the projects PID2023-151610OB-C22 and PID2020-118946RB-I00 funded by Spanish Ministry of Science, Innovation and Universities (MICIU/AEI/https://doi.org/10.13039/501100011033)and FEDER, UE and the "European Union NextGenerationEU/PRTR" [PID2020-118480RB-C21, PDC2021-121368-C22].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Aplicación de termografía infrarroja en la estimación de la vida a fatiga en laminados de CFRP taladrados.

  • Calvo, Jose Vicente|||0000-0001-8488-1762
  • Feito-Sánchez, Norberto|||0000-0001-7330-6404
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Miguélez, María Henar
[ES] La aplicación de técnicas no destructivas para evaluar materiales compuestos sometidos a fatiga es un área de creciente interés entre la comunidad científica. Entre las técnicas disponibles, destaca el uso de la termografía infrarroja debido a su asequibilidad, simplicidad y resultados prometedores en investigaciones previas. En este estudio, se aplica la termografía infrarroja con el objetivo de obtener modelos predictivos capaces de estimar el límite de fatiga de laminados gruesos de CFRP (polímero reforzado con fibra de carbono) sometidos a cargas de tracción. Los ensayos experimentales conllevan la monitorización de la temperatura en laminados con características típicas de la industria aeroespacial, a través de una cámara termográfica. La campaña experimental implica la variación de los niveles de daño por taladrado y las cargas cíclicas de tracción. Con los datos obtenidos de la evolución de la temperatura durante la fase inicial de los ensayos de fatiga se obtienen modelos analíticos predictivos del límite de fatiga. Los resultados indican que el modelo propuesto es capaz de predecir de manera eficiente el límite de fatiga con una alta fiabilidad, mostrando una sólida correlación entre las predicciones y los resultados experimentales, por lo que este estudio subraya la utilidad de las técnicas termográficas para evaluar el daño y predecir el límite de fatiga de laminados CFRP en diversas condiciones de carga, Los autores agradecen la financiación a través de los siguientes proyectos: PID2020-118480RB-C21 y C22, financiado por MCIN/AEI/ 10.13039/501100011033 y por FEDER Una manera de hacer Europa ; proyecto PDC2021-121368-C21 y C22 financiado por MCIN/AEI/ 10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR ; ayuda PRE2018-086277 financiada por MCIN/AEI/10.13039 /501100011033 y por FSE Invierte en tu futuro . También agradecen la financiación de la Generalitat Valenciana, programa PROMETEO 2021/046 y el proyecto GV/2021/060.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Estudio de la fractura a compresión de hueso trabecular sano, osteoporótico y artrósico procedente de cabezas femorales humanas

  • Megías-Díaz, Raquel|||0000-0002-1698-7108
  • Belda Ricardo|||0000-0003-3913-5773
  • Vercher Martínez, Ana|||0000-0003-3695-6461
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
[ES] En este trabajo se ha estudiado el comportamiento mecánico del hueso trabecular mediante ensayos experimentales de compresión y el desarrollo de modelos numéricos de elementos finitos. Las muestras proceden de cabezas femorales humanas y se agruparon en tres cohortes: grupo sano (GS), grupo osteoporótico (GO) y grupo artrósico (GA). Los especímenes se ensayaron en la dirección estimada de máxima rigidez y se sometieron a cargas de compresión cuasiestática hasta la fractura. La respuesta experimental permitió calibrar los modelos numéricos, estimando el módulo de Young del tejido óseo y las propiedades de fallo de las muestras. Los resultados muestran que el hueso sano soporta un 52% más de carga que el hueso osteoporótico, y que la deformación correspondiente a la tensión máxima es un 33% mayor en el GS que en el GO. Las muestras artrósicas presentan un comportamiento intermedio, más próximo al grupo osteoporótico que al sano, lo que indica que las patologías analizadas se asocian a menores niveles de carga y deformación frente al hueso sano. La calibración de los modelos numéricos proporciona valores similares de deformación de inicio de fallo y de fallo completo para las muestras patológicas, mientras que en las muestras sanas estos valores difieren. En consecuencia, la simulación de la fractura en hueso osteoporótico requiere considerar propiedades de fallo específicas, coherentes con un comportamiento más frágil que el del hueso sano. Finalmente, este trabajo permite cuantificar dichos parámetros e identifica como principal origen de las diferencias las características morfométricas propias de la microestructura del hueso trabecular no sano., Los autores desean agradecer la financiación recibida desde la GVA por el Plan FDEGENT 2018 GVA y por el programa PROMETEO 2021/046, y por los proyectos PID2020-118920RB-I00 y PID2020-118480RB-C21 y C22, financiado por MCIN/AEI/10.13039/501100011033 y por FEDER Una manera de hacer Europa y el proyecto PDC2021-121368-C21 y C22 financiado por MCIN/AEI/10.13039/501100011033 y por la Unión Europea NextGenerationEU/PRTR .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Numerical analysis of the influence of triply periodic minimal surface structures morphometry on the mechanical response

  • Belda Ricardo|||0000-0003-3913-5773
  • Megías-Díaz, Raquel|||0000-0002-1698-7108
  • Vercher Martínez, Ana|||0000-0003-3695-6461
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Marco, Miguel
[EN] Background and Objective: Design of bone scaffolds requires a combination of material and geometry to fulfil requirements of mechanical properties, porosity and pore size. Triply Periodic Minimal Surface (TPMS) structures have gained attention due to their similarities to cancellous bone. In this work, we aim at exploring relationships between morphometry and mechanical properties for TPMS configurations.Methods: Eight TPMS structures are defined considering six porosity levels and their morphometry is characterized. The stiffness matrix of each structure is assessed and related to morphometry through a statistical analysis.Results: An orthotropic mechanical behavior has been derived from the numerical homogenization. Prop-erties decay exponentially for decreasing volume fraction. Through volume fraction variation, TPMS me-chanical properties can be selected to match bone properties in a range of 0.2% to 70% of the bulk mate-rial properties.Conclusions: The comparison between cancellous bone and TPMS morphometry, considering a unit cell size of 1.5 mm, reveals that the configurations analyzed in this work match the requirements of volume fraction, mean thickness and pore size. However, the TPMS studied in this work differ from cancellous bone anisotropy. The results in this paper provide a framework to select the proper TPMS configuration and its geometry for patient-specific applications., This work was supported by the Spanish Ministerio de Ciencia e Innovacion MCIN/AEI/10.13039/501100011033 through grant numbers PID2020-118480RB-C21, PID2020-118920RB-I0 0 and PID2020-112628RA-I0 0, the European Union NextGenerationEU/PRTR through grant number PDC2021-121368-C22 and the Generalitat Valenciana (Programme PROMETEO 2021/046 and Plan FDGENT 2018 GVA).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Influence of distributed out-of-plane waviness defects on the mechanical behavior of CFRP laminates

  • Calvo, Jose Vicente|||0000-0001-8488-1762
  • Quiñonero-Moya, Antonio Ramón|||0000-0002-2370-7960
  • Feito-Sánchez, Norberto|||0000-0001-7330-6404
  • Giner Maravilla, Eugenio|||0000-0003-1903-6495
  • Miguélez, María Henar
[EN] One of the most common defects induced during manufacturing of laminates is out-of-plane fibre waviness. This defect significantly affects the mechanical behavior of the laminate and reduces fatigue life and the load capacity of the material. Therefore, it is important to understand the impact of fibre waviness on the performance of composite laminates. In this work, multiple out-of-plane waves have been introduced throughout a Carbon Fibre Reinforced Polymer (CFRP) laminate at different thickness positions. The specimens were tested under tensile loading and an analysis of the surface of the laminate has been carried out by means of Digital Image Correlation (DIC). The results obtained by DIC were able to predict the apparent strain of the laminate quite accurately, as well as locate up to seven undulations at different depths. It was proved that a laminate with multiple wrinkles has 16% less tensile load strength. The results were used to validate different Finite Element (FE) models of the laminate showing a good agreement. These simple models were able to predict the initiation and propagation of failure in both the matrix and the fibre., This research is part of the R + D + i project PID2020-118480RB-C21 and C22, funded by MCIN/AEI/10.13039/501100011033 and by "ERDF A way of making Europe". Grant PDC2021-121368-C21 and C22 funded by MCIN/AEI/10.13039/501100011033 and by the "European Union NextGenerationEU/PRTR". Grant PRE2018-086277 and PRE2021-097626 funded by MCIN/AEI/10.13039/501100011033 and by "ESF Investing in your future". The funding of the Generalitat Valenciana, Programme PROMETEO 2021/046 and project GV/2021/060, is also acknowledged.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

The role of the interfaces and cross-links on the mechanical behavior of mineralized collagen fibrils. A numerical approach

  • Vercher-Martínez, Ana
  • Giner, Eugenio
  • Fuenmayor, F. Javier
  • García-Aznar, J. Manuel
Mechanical properties of bone tissue are highly dependent on its hierarchical structure. The presence of microcracks and diffuse damage in lamellar bone is correlated with the failure of the collagen-mineral interface in mineralized collagen fibrils (MCF). The main goal of this work is to evaluate the mechanical behavior of the interfaces and quantify the stiffness loss of the MCF associated with different failure mechanisms, under controlled in-plane displacement. Additionally, we aim to study the role of the cross-links on the fibril mechanical response, beyond the interface failure. Inter- and intra-microfibrilar cross-links are analyzed. In order to address the first issue, a detailed representative volume of the MCF is analyzed by means of the finite element method, under the assumption of plane strain and periodic boundary conditions. In this model the interfaces between constituents are modeled with an exponential cohesive law. Enzymatic cross-links, located at the molecular terminals connecting each 4D ( ) staggered molecules, are represented by non-linear springs. Three in-plane controlled deformations are applied. The results of this work provide the anisotropic stiffness loss of the tissue involved in the different failure mechanisms at the nano-scale length. The initiation of microcracks and the presence of damage zones are compatible with the failure mechanisms observed at interfaces. Interface failure entails a progressive stiffness loss, bringing a non-linear behavior of bone. The strength obtained for the longitudinal maximum deformation is more than 20 times the transverse strength and 3.5 times the shear strength. The quantification of the reduction percentage in the elastic moduli and the shear stiffness when the fibril is damaged, has a potential application in improving failure criteria based on degradation of elastic constants. When longitudinal elongation is applied, the mechanical contribution of the cross-links in delaying the failure initiation of the interface is shown. Likewise, results of this work confirm the scarce influence of the cross-links in the strain range analyzed. Additionally, a three-dimensional numerical model of several microfibrils is defined with the aim of analyzing the mechanical relevance of inter- and intra-microfibrilar cross-links, beyond the interface failure. Results confirm that cross-links transfer the load when strain increases, being highlighted the mechanical competence of the trivalent cross-links.