Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Geometric, Biomechanic and Haemodynamic Aortic Abnormalities Assessed by 4D Flow Cardiovascular Magnetic Resonance in Patients Treated by TEVAR Following Blunt Traumatic Thoracic Aortic Injury

  • Gil-Sala, Daniel|||0000-0003-4885-5836
  • Guala, Andrea|||0000-0002-5006-8164
  • Garcia Reyes, Marvin
  • Azancot, María A.|||0000-0002-8447-1373
  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Allegue Allegue, Nicolas
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
  • Goncalves Martins, Gabriela
  • Ruiz Muñoz, Aroa|||0000-0002-1138-8528
  • Constenla Garcia, Ivan|||0000-0002-7107-2277
  • Evangelista Masip, Arturo|||0000-0001-8182-1174
  • Tello Díaz, Cristina
  • Ferreira-Gonzalez, Ignacio|||0000-0002-1208-5561
  • Rodríguez Palomares, José F.|||0000-0002-7229-9780
  • Bellmunt Montoya, Sergi|||0000-0002-2851-720X
Objective: Thoracic endovascular aortic repair (TEVAR) is widely used for the treatment of patients with blunt traumatic thoracic aortic injury (BTAI). However, aortic haemodynamic and biomechanical implications of this intervention are poorly investigated. This study aimed to assess whether patients treated by TEVAR following BTAI have thoracic aortic abnormalities in geometry, stiffness, and haemodynamics. Methods: Patients with BTAI treated by TEVAR at Vall d'Hebron Hospital between 1999 and 2019 were compared with propensity score matched healthy volunteers (HVs). All subjects underwent cardiovascular magnetic resonance (CMR) comprising a 4D flow CMR sequence. Spatially resolved aortic diameter, length, volume, and curvature were assessed. Pulse wave velocity, distensibility, and longitudinal strain (all measurements of aortic stiffness) were determined regionally. Moreover, advanced haemodynamic descriptors were quantified: systolic flow reversal ratio (SFRR), quantifying backward flow during systole, and in plane rotational flow (IRF), measuring in plane strength of helical flow. Results: Twenty-six BTAI patients treated by TEVAR were included and matched with 26 HVs. They did not differ in terms of age, sex, and body surface area. Patients with TEVAR had a larger and longer ascending aorta (AAo) and marked abnormalities in local curvature. Aortic stiffness was greater in the aortic segments proximal and distal to TEVAR compared with controls. Moreover, TEVAR patients presented strongly altered flow dynamics compared with controls: a reduced IRF from the distal AAo to the proximal descending aorta and an increased SFRR in the whole thoracic aorta. These differences persisted adjusting for cardiovascular risk factors and were independent of time elapsed since TEVAR implantation. Conclusion: At long term follow up, previously healthy patients who underwent TEVAR implantation following BTAI had increased diameter, length and volume of the ascending aorta, and increased aortic stiffness and abnormal flow patterns in the whole thoracic aorta compared with matched controls. Further studies should address whether these alterations have clinical implications.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Estimating nonlinear anisotropic properties of healthy and aneurysm ascending aortas using magnetic resonance imaging

  • Latorre Molins, Álvaro T.
  • Guala, Andrea|||0000-0002-5006-8164
  • Dux-Santoy, Lydia|||0000-0001-8736-2095
  • Teixido-Tura, Gisela|||0000-0003-4714-2420
  • Rodríguez Palomares, José Fernando|||0000-0002-8822-5532
  • Martínez Barca, Miguel Ángel
  • Peña Baquedano, Estefanía
An ascending aortic aneurysm is an often asymptomatic localized dilatation of the aorta. Aortic rupture is a life-threatening event that occurs when the stress on the aortic wall exceeds its mechanical strength. Therefore, patient-specific finite element models could play an important role in estimating the risk of rupture. This requires not only the geometry of the aorta but also the nonlinear anisotropic properties of the tissue. In this study, we presented a methodology to estimate the mechanical properties of the aorta from magnetic resonance imaging (MRI). As a theoretical framework, we used finite element models to which we added noise to simulate clinical data from real patient geometry and different properties of healthy and aneurysmal aortic tissues collected from the literature. The proposed methodology considered the nonlinear properties, the zero pressure geometry, the heart motion, and the external tissue support. In addition, we analyzed the aorta as a homogeneous material and as a heterogeneous model with different properties for the ascending and descending parts. The methodology was also applied to pre-surgical, in vivo MRI data of a patient who underwent surgery during which an aortic wall sample was obtained. The results were compared with those obtained from ex vivo biaxial test of the patient's tissue sample. The methodology showed promising results after successfully recovering the nonlinear anisotropic material properties of all analyzed cases. This study demonstrates that the variable used during the optimization process can affect the result. In particular, variables such as principal strains were found to obtain more realistic materials than the displacement field.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Comparative analysis of aortic stiffness: magnetic resonance validation against mechanical testing in ex vivo aortic specimens

  • Guala, Andrea
  • Cilla, Myriam
  • Teixido-Tura, Gisela
  • Martínez, Miguel Angel
  • Dux-Santoy Hurtado, Lydia
  • Galian-Gay, Laura
  • Garrido-Oliver, Juan
  • Latorre, Alvaro
  • Servato, Maria Luz
  • Majul, Horacio
  • Hernandez-Pineda, Axel Hiram
  • Granato, Chiara
  • Ferreira-González, Ignacio
  • Evangelista, Arturo
  • Peña, Estefania
  • Rodriguez-Palomares, Jose
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Three-dimensional aortic geometry mapping via registration of non-gated contrast-enhanced or gated and respiratory-navigated MR angiographies

  • Teixido-Tura, Gisela
  • Garrido Oliver, Juan
  • Carrasco-Poves, Alejandro
  • Morales-Galán, Alberto
  • Ruiz Muñoz, Aroa
  • Casas Masnou, Guillem
  • Valente, Filipa
  • Galián Gay, Laura
  • Fernández Galera, Ruben
  • Cuellar-Calabria, Hug
  • Roque Pérez, Alberto
  • Burcet Rodríguez, Gemma
  • Ferreira González, Ignacio
  • Dux-Santoy Hurtado, Lydia
  • Rodríguez Palomares, José F
  • Barrabés, José A.
  • Guala, Andrea
  • Oliveró, Ruperto
Aortic aneurysm; Aortic dilation; Magnetic resonance angiography, Aneurisma aórtico; Dilatación aórtica; Angiografía por resonancia magnética, Aneurisma aòrtic; Dilatació aòrtica; Angiografia per ressonància magnètica, Background The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). Methods Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. Results Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). Conclusion Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases., This study has been supported by funding from the Instituto de Salud Carlos III (projects PI19/01480, PI20/01727 and PI21/00448), the Spanish Ministry of Science, Innovation and Universities (RTC2019-007280-1), the Spanish Society of Cardiology (SEC/FEC-INV-CLI 20/015), and the Biomedical Research Networking Center on Cardiovascular Diseases (CIBERCV). Guala A. has received funding from “la Caixa” Foundation (LCF/BQ/PR22/11920008). Garrido-Oliver J. has received funding from Secretaria d′Universitats i Recerca del Departament de Recerca i Universitats de la Generalitat de Catalunya i del Fons Europeu Social Plus (AGAUR-FI 2023 FI-1 00322 Joan Oró).
Scientia. Dipòsit d'Informació Digital del Departament de Salut
Publication Artículo científico (JournalArticle)

Three-dimensional aortic geometry mapping via registration of non-gated contrast-enhanced or gated and respiratory-navigated MR angiographies

  • Teixido-Tura, Gisela
  • Garrido Oliver, Juan
  • Carrasco-Poves, Alejandro
  • Morales-Galán, Alberto
  • Ruiz Muñoz, Aroa
  • Casas Masnou, Guillem
  • Valente, Filipa
  • Galián Gay, Laura
  • Fernández Galera, Ruben
  • Cuellar-Calabria, Hug
  • Roque Pérez, Alberto
  • Burcet Rodríguez, Gemma
  • Ferreira González, Ignacio
  • Dux-Santoy Hurtado, Lydia
  • Rodríguez Palomares, José F
  • Barrabés, José A.
  • Guala, Andrea
  • Oliveró, Ruperto
Aortic aneurysm; Aortic dilation; Magnetic resonance angiography, Aneurisma aórtico; Dilatación aórtica; Angiografía por resonancia magnética, Aneurisma aòrtic; Dilatació aòrtica; Angiografia per ressonància magnètica, Background The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). Methods Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. Results Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). Conclusion Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases., This study has been supported by funding from the Instituto de Salud Carlos III (projects PI19/01480, PI20/01727 and PI21/00448), the Spanish Ministry of Science, Innovation and Universities (RTC2019-007280-1), the Spanish Society of Cardiology (SEC/FEC-INV-CLI 20/015), and the Biomedical Research Networking Center on Cardiovascular Diseases (CIBERCV). Guala A. has received funding from “la Caixa” Foundation (LCF/BQ/PR22/11920008). Garrido-Oliver J. has received funding from Secretaria d′Universitats i Recerca del Departament de Recerca i Universitats de la Generalitat de Catalunya i del Fons Europeu Social Plus (AGAUR-FI 2023 FI-1 00322 Joan Oró).