RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Effect of the trabecular bone microstructure on measuring its thermal conductivity: A computer modeling-based study

  • Fajardo, Jesús E.
  • Carlevaro, C. Manuel
  • Vericat, Fernando
  • Irastorza, Ramiro Miguel
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] The objective of this work is to quantify the relation between the value of the effective thermal conductivity of trabecular bone and its microstructure and marrow content. The thermal conductivity of twenty bovine trabecular bone samples was measured prior to and after defatting at 37, 47, and 57 degrees C. Computer models were built including the microstructure geometry and the gap between the tissue and measurement probe. The thermal conductivity (k) measured was 0.39 +/- 0.06 W m(-1) K-1 at 37 degrees C, with a temperature dependence of + 0.2%degrees C-1. Replacing marrow by phosphate-buffered saline (defatting) increased both the computer simulations and measurement results by 0.04 W m(-1) K-1. The computer simulations showed that k increases by 0.02-0.04 W m(-1) K-1 when the model includes a gap filled by phosphate-buffered saline between the tissue and measurement probe. In the presence of microstructure and fatty red marrow, k varies by +/- 0.01 W m(-1) K-1 compared with the case considering matrix only, which suggests that there are no significant differences between cortical and trabecular bone in terms of k. The computer results showed that the presence of a gap filled by phosphate-buffered saline around the energy applicator changes maximum temperature by < 0.7 degrees C, while including the bone microstructure involved a variation of < 0.2 mm in the isotherm location. Future experimental studies on measuring the value of k involving the insertion of a probe into the bone through a drill hole should consider the bias found in the simulations. Thermal models based on a homogeneous geometry (i.e. ignoring the microstructure) could provide sufficient accuracy., This work was supported by a grant from the "Agencia Nacional de Promocion Cientfica y Tecnologica de Argentina" (Ref. PICT-2016-2303), by the National Scientific and Technical Research Council of Argentina (Grant PIO CONICET-UNAJ 0001), and by the Spanish "Programa Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" under Grant TEC2014-52383-C3-R (TEC2014-52383-C3-1-R).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Limitations of Baseline Impedance, Impedance Drop and Current for Radiofrequency Catheter Ablation Monitoring: Insights from In Silico Modeling

  • Irastorza, Ramiro M.
  • Maher, Timothy
  • Barkagan, Michael
  • Liubasuskas, Rokas
  • D Avila, Andre
  • Pérez, Juan J|||0000-0001-8486-8699
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Background: Baseline impedance, radiofrequency current, and impedance drop during radiofrequency catheter ablation are thought to predict effective lesion formation. However, quantifying the contributions of local versus remote impedances provides insights into the limitations of indices using those parameters. Methods: An in silico model of left atrial radiofrequency catheter ablation was used based on human thoracic measurements and solved for (1) initial impedance (Z), (2) percentage of radiofrequency power delivered to the myocardium and blood (3) total radiofrequency current, (4) impedance drop during heating, and (5) lesion size after a 25 W¿30 s ablation. Remote impedance was modeled by varying the mixing ratio between skeletal muscle and fat. Local impedance was modeled by varying insertion depth of the electrode (ID). Results: Increasing the remote impedance led to increased baseline impedance, lower system current delivery, and reduced lesion size. For ID = 0.5 mm, Z ranged from 115 to 132 ¿ when fat percentage varied from 20 to 80%, resulting in a decrease in the RF current from 472 to 347 mA and a slight decrease in lesion size from 5.6 to 5.1 mm in depth, and from 9.2 to 8.0 mm in maximum width. In contrast, increasing the local impedance led to lower system current but larger lesions. For a 50% fat¿muscle mixture, Z ranged from 118 to 138 ¿ when ID varied from 0.3 to 1.9 mm, resulting in a decrease in the RF current from 463 to 443 mA and an increase in lesion size, from 5.2 up to 7.5 mm in depth, and from 8.4 up to 11.6 mm in maximum width. In cases of nearly identical Z but different contributions of local and remote impedance, markedly different lesions sizes were observed despite only small differences in RF current. Impedance drop better predicted lesion size (R2 > 0.93) than RF current (R2 < 0.1). Conclusions: Identical baseline impedances and observed RF currents can lead to markedly different lesion sizes with different relative contributions of local and remote impedances to the electrical circuit. These results provide mechanistic insights into the advantage of measuring local impedance and identifies potential limitations of indices incorporating baseline impedance or current to predict lesion quality, Spanish Ministerio de Ciencia, Innovación y Universidades / Agencia Estatal de Investigación (MCIN/AEI/10.13039/501100011033) under grant RTI2018-094357-B-C21, and Agencia Nacional de Promoción Científica y Tecnológica de Argentina, grant PICT-2016-2303. Dr. Irastorza was the recipient of a scholarship of the Programa de Becas Externas Postdoctorales para Jóvenes Investigadores del CONICET (Argentina).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Anterior vs. posterior position of dispersive patch during radiofrequency catheter ablation: Insights from in-silico modeling

  • Irastorza, Ramiro M.
  • Maher, Timothy
  • Barkagan, Michael
  • Liubasuskas, Rokas
  • D Avila, Andre
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Aims: To test the hypothesis that the dispersive patch (DP) location does not significantly affect the current distribution around the catheter tip during radiofrequency catheter ablation (RFCA) but may affect lesions size through differences in impedance due to factors far from the catheter tip. Methods: An in silico model of RFCA in the posterior left atrium and anterior right ventricle was created using anatomic measurements from patient thoracic computed tomography scans and tested the effect of anterior vs. posterior DP locations on baseline impedance, myocardial power delivery, radiofrequency current path, and predicted lesion size. Results: For posterior left atrium ablation, the baseline impedance, total current delivered, current distribution, and proportion of power delivered to the myocardium were all similar with both anterior and posterior DP locations, resulting in similar RFCA lesion sizes (< 0.2 mm difference). For anterior right ventricular (RV) ablation, an anterior DP location resulted in slightly higher proportion of power delivered to the myocardium and lower baseline impedance leading to slightly larger RFCA lesions (0.6 mm deeper and 0.8 mm wider). Conclusions: An anterior vs. posterior DP location will not meaningfully affect RFCA for posterior left atrial ablation, and the slightly larger lesions predicted with anterior DP location for anterior RV ablation are of unclear clinical significance., This study was supported by Spanish MCIN/AEI/10.13039/501100011033 (E.B.; Grant RTI2018-094357-B-C21), Agencia Nacional de Promoción Científica y Tecnológica de Argentina (R.I.; PICT-2016-2303), and Programa de Becas Externas Postdoctorales para Jóvenes Investigadores del CONICET (R.I.).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Effect of the relative position of electrode and stellate ganglion during thermal radiofrequency ablation: a simulation study

  • Irastorza, Ramiro M.
  • Bovaira, Maite
  • García-Vitoria, Carles
  • Muñoz, Víctor
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Purpose Stellate ganglion (SG) block by thermal radiofrequency ablation (RFA) is frequently conducted as a therapeutic intervention for sympathetic-maintained and neuropathic pain syndromes. RFA's partial lack of effectiveness could be partly due to the ablation zone (AZ) not completely covering the SG section and therefore preventing the 'cutting' of the afferent pathways. Our objective was to build a theoretical model to conduct computer simulations to assess the effect of the electrode position relative to the SG. Methods A three-dimensional model was built including the SG and adjacent tissues (vertebrae C7-T1-T2, trachea, carotid artery and vertebral artery). RFA (90-s, 80 degrees C) was simulated considering a 22 G-5 mm electrode. The AZ was computed using the 50 degrees C isotherm. Results An electrode displacement of 2 mm in any direction from the optimal position (centered on the SG) meant that the AZ did not fully cover the SG section. Likewise, SG size considerably affected the RFA effectiveness since the AZ fully covered the section of small but not large SGs. Conclusions The findings suggest that the currently used SG RFA settings (i.e., 22 G-5 mm electrode, 90-s, 80 degrees C) may not be appropriate due to their inability to achieve an AZ that fully covers the SG cross section under certain circumstances, such as a large SG and non-optimal positioning of the RF electrode with respect to the SG center., This work was supported by the Spanish Ministerio de Ciencia, Innovacion y Universidades under the 'Programa Estatal de I+D+i orientada a los retos de la Sociedad', Grant No 'RTI2018-094357-B-C21', the Universidad Nacional Arturo Jauretche - Argentina 'UNAJ Investiga' [80020170100019UJ], and by the 'Agencia Nacional de Promocion Cientifica y Tecnologica de Argentina' [PICT-2016-2303].
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Differences in applied electrical power between full thorax models and limited domain models for RF cardiac ablation

  • Irastorza, Ramiro M.
  • González-Suárez, Ana|||0000-0002-1813-4176
  • Pérez, Juan J|||0000-0001-8486-8699
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Purpose:Most modeling studies on radiofrequency cardiac ablation (RFCA) are based on limited-domain models, which means the computational domain is restricted to a few centimeters of myocardium and blood around the active electrode. When mimicking constant power RFCA procedures (e.g., atrial fibrillation ablation) it is important to know how much power is absorbed around the active electrode and how much in the rest of the tissues before reaching the dispersive electrode. Methods:3D thorax full models were built by progressively incorporating different organs and tissues with simplified geometries (cardiac chamber, cardiac wall, subcutaneous tissue and skin, spine, lungs and aorta). Other 2D limited-domain models were also built based on fragments of myocardium and blood. The electrical problem was solved for each model to estimate the spatial power distribution around the active electrode. Results:From 79 to 82% of the power was absorbed in a 4 cm-radius sphere around the active electrode in the full thorax model at active electrode insertion depths of between 0.5 and 2.5 mm, while the impedance values ranged from 104 to 118 omega, which were consistent with those found (from 83 to 103 omega) in a 4 cm radius cylindrical limited domain model. Conclusion:The applied power in limited-domain RFCA models is approximately 80% of that applied in full thorax models, which is equivalent to the power programed in a clinical setting., This work was supported by the Spanish Ministerio de Economia, Industria y Competitividad under `Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad', Grant No [RTI2018094357-B-C21], by the Universidad Nacional Arturo Jauretche Argentina 'UNAJ Investiga' [80020170100019UJ], and by `Agencia Nacional de Promocion Cientifica y Tecnologica de Argentina' [PICT2016-2303].