Skip to main content

APROXIMACIONES ANALITICAS INNOVADORAS DE BIOSENSADO BASADAS EN MICROFLUIDICA ELECTROQUIMICA Y MICROMOTORES ARTIFICIALES PARA EL ANALISIS DE BIOMARCADORES CLINICOS.

PID2020-118154GB-I00

•
Funding agency name Agencia Estatal de Investigación
Funding agency acronym AEI
Program Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Call Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Call year 2020
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre UNIVERSIDAD DE ALCALA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 20
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

A dual colorimetric-electrochemical microfluidic paper-based analytical device for point-of-care testing of ischemic strokes

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • Pacheco Jerez, Marta|||0000-0001-9546-9108
  • Gasull Dalmau, Teresa|||0000-0002-9321-1741
  • Crevillen, Agustín G.|||0000-0002-4470-6502
  • Escarpa, Alberto|||0000-0002-7302-0948
A novel microfluidic paper-based analytical device with dual colorimetric and electrochemical detection (dual μPAD) was developed for the assessment of transferrin saturation (TSAT) in samples from ischemic stroke patients. TSAT was calculated from the ratio between transferrin-bound iron, which was colorimetrically measured, and the total iron-binding capacity, which was electrochemically measured. To this end, a μPAD was smartly designed, which integrated both colorimetric and electrochemical detection reservoirs, communicating via a microchannel acting as a chemical reactor, and with preloading/storing capabilities (reagent-free device). This approach allowed the dual and simultaneous determination of both parameters, providing an improvement in the reliability of the results due to an independent signal principle and processing. The μPADs were validated by analyzing a certified reference material, showing excellent accuracy (E ≤ 5%) and precision (RSD ≤ 2%). Then they were applied to the analysis of diagnosed serum samples from ischemic stroke patients. The results were compared to those provided by a free-interference method (urea-PAGE). Impressively, both methods exhibited a good correlation (r = 0.96, p < 0.05) and no significant differences were found between them (slope 1.0 ± 0.1 and the intercept 1 ± 4, p < 0.05), demonstrating the excellent accuracy of our approach during the analysis of complex samples from ischemic stroke patients, using just 90 μL of clinical samples and taking less than 90 min in comparison with the 18 hours required by the urea-PAGE approach. The developed fully integrated colorimetric-electrochemical μPAD is a promising ready to use reagent-free device for the point-of-care testing of TSAT, which can be used to assist physicians in the fast diagnosis and prognosis of ischemic strokes, where the decision-time is crucial for the patient's survival.
Repisalud
Publication Artículo científico (JournalArticle)

Gold Nanoparticle-Decorated Catalytic Micromotor-Based Aptassay for Rapid Electrochemical Label-Free Amyloid-β42 Oligomer Determination in Clinical Samples from Alzheimer's Patients

  • Gallo-Orive, Álvaro
  • Moreno-Guzmán, María
  • Sanchez-Paniagua, Marta
  • Montero-Calle, Ana Maria
  • Barderas Manchado, Rodrigo
  • Escarpa, Alberto
Micromotor (MM) technology offers a valuable and smart on-the-move biosensing microscale approach in clinical settings where sample availability is scarce in the case of Alzheimer's disease (AD). Soluble amyloid-β protein oligomers (AβO) (mainly AβO) that circulate in biological fluids have been recognized as a molecular biomarker and therapeutic target of AD due to their high toxicity, and they are correlated much more strongly with AD compared to the insoluble Aβ monomers. A graphene oxide (GO)-gold nanoparticles (AuNPs)/nickel (Ni)/platinum nanoparticles (PtNPs) micromotors (MM)-based electrochemical label-free aptassay is proposed for sensitive, accurate, and rapid determination of AβO in complex clinical samples such as brain tissue, cerebrospinal fluid (CSF), and plasma from AD patients. An approach that implies the in situ formation of AuNPs on the GO external layer of tubular MM in only one step during MM electrosynthesis was performed (MM). The AβO specific thiolated-aptamer (Apt) was immobilized in the MM via Au-S interaction, allowing for the selective recognition of the AβO (MM-Apt-AβO). AuNPs were smartly used not only to covalently bind a specific thiolated-aptamer for the design of a label-free electrochemical aptassay but also to improve the final MM propulsion performance due to their catalytic activity (approximately 2.0× speed). This on-the-move bioplatform provided a fast (5 min), selective, precise (RSD < 8%), and accurate quantification of AβO (recoveries 94-102%) with excellent sensitivity (LOD = 0.10 pg mL) and wide linear range (0.5-500 pg mL) in ultralow volumes of the clinical sample of AD patients (5 μL), without any dilution. Remarkably, our MM-based bioplatform demonstrated the competitiveness for the determination of AβO in the target samples against the dot blot analysis, which requires more than 14 h to provide qualitative results only. It is also important to highlight its applicability to the potential analysis of liquid biopsies as plasma and CSF samples, improving the reliability of the diagnosis given the heterogeneity and temporal complexity of neurodegenerative diseases. The excellent results obtained demonstrate the analytical potency of our approach as a future tool for clinical/POCT (Point-of-care testing) routine scenarios.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Paper-Based Analytical Devices for Accurate Assessment of Transferrin Saturation in Diagnosed Clinical Samples from Ischemic Stroke Patients

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • Gregorio-Rocasolano Barbany, Núria de|||0000-0001-5248-7525
  • Millán Torné, Mònica|||0000-0002-4692-5936
  • Gasull Dalmau, Teresa|||0000-0002-9321-1741
  • Crevillen, Agustín G.|||0000-0002-4470-6502
  • Escarpa, Alberto|||0000-0002-7302-0948
For the first time, a paper-based analytical device (PAD) was developed for the assessment of transferrin saturation (TSAT), which is defined as the ratio between iron bound to transferrin (Tf) and the total iron-binding capacity (TIBC) of Tf. Both parameters were simultaneously measured on the same PAD using ferrozine as a chromophore and a smartphone as the color reader. To this end, Tf was first isolated from serum using anti-Tf immunomagnetic beads to ensure that only the Tf-bound iron was measured, improving the selectivity and accuracy of TSAT assessment. To demonstrate the practical utility of the device, it was validated by analyzing a certified reference material, showing excellent accuracy (E < 4%) and good precision (RSD ≤ 6%). Finally, 18 diagnosed serum samples from ischemic stroke patients were analyzed by this approach, and the results were compared with those obtained by urea-PAGE, showing not only an excellent correlation (r = 0.93, p < 0.05) but that the PAD approach has become statistically identical to the free-interference urea-PAGE. In comparison with the slow, tedious, and non-miniaturized-PAGE, this PAD approach exhibited attractive characteristics such as low cost, disposability, and connectivity, showing great potential for future point-of-care testing, especially in developing countries and/or remote areas, where access to medical or clinical facilities is limited.
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

OFF-ON on-the-fly aptassay for rapid and accurate determination of procalcitonin in very low birth weight infants with sepsis suspicion

  • Gordón Pidal, José María|||0000-0001-8465-3268
  • Arruza Gómez, Luis
  • Moreno Guzmán, María
  • López Gil, Miguel Ángel|||0000-0003-3711-010X
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
A fast and reliable OFF-ON micromotors (MM)-based aptassay for rapid, sensitive, and accurate determination of procalcitonin (PCT) as one of the leading neonatal sepsis biomarkers in very low birth weight infants? serum samples is proposed. MM were composed of three specific functional layers: graphene oxide (GO) as sensing layer, Ni for magnetic guidance and platinum nanoparticles (PtNPs) as catalytic layer for self-propulsion (MMGO/ Ni/PtNPs). The OFF-ON strategy relies on the binding of the aptamer tagged with alexa-405 as fluorescent label (AptPCT, ?em=447 nm) onto the GO outer layer of the MM (GOMM) to induce its fluorescence quenching (GOMMAptPCT, OFF state); which is next recovered due to selectively binding of the aptamer to the PCT and their separation from the GOMM surface (PCT-AptPCT, ON state). The fast OFF-ON on-the-fly aptassay allowed in just 5 min a highly selective and sensitive (LOD = 0.01 ng mL? 1) PCT determination in clinical samples from very low birth weight infants with sepsis suspicion, using only 25 ?L of sample in a clinically relevant range of concentrations (0.03?1280 ng mL? 1). The high concordance between the PCT levels obtained by our MMGO/Ni/PtNPsbased aptassay and those obtained by the Hospital, demonstrated the analytical potency of our approach for the analysis of neonatal samples as well as its potential to be used as a pre-diagnostic tool for sepsis., Ministerio de Ciencia e Innovación, Comunidad de Madrid, European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Micromotors Meet Collective (Bio)sensing: The Asset Behind the Assay

  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
Micromotors are microscale devices with enormous potential for analytical (bio)sensing due to autonomous motion capabilities in extremely small sample volumes or for guided detection in localized hard-to-reach areas. These unique features enable dynamic interactions with the analytes, offering considerable promise in microscale environments and opening new avenues for on-the-fly (bio)sensing strategies. By selecting and discussing the ideas and findings behind pioneering works, we offer our perspective on the current state of the art in the field of in vitro (bio)sensing approaches based on the micromotors classified according to their detection principle: motion-based, optical, and electrochemical sensing. We will also draw attention to current challenges and opportunities that have not yet been fully explored, in a landscape that is as exciting as it is changing., Agencia Estatal de Investigación, Junta de Comunidades de Castilla-La Mancha
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Integrated calibration and serum iron in situ analysis into an array microfluidic paper-based analytical device with smartphone readout

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • Crevillen, Agustín G.
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
7 p., In this work, a colorimetric microfluidic paper-based analytical device (mu PAD) combined with a smartphone readout was proposed for the determination of serum iron (Fe3+), which is linked to transferrin. Firstly, Fe3+ was selectively isolated and preconcentrated from serum by using anti-transferrin immunomagnetic beads (anti-Tf-MBs). Secondly, Fe3+ is reduced to Fe2+ by a hydroxylamine solution (pH 4.8) and then measured in the mu PAD, which contains the colorimetric reagent ferrozine. Finally, the intensity of the purple color formed in the mu PAD was measured by a smartphone. The approach exhibited an excellent linear correlation (r = 0.996) and good limit of detection (0.3 mu g mL(-1)). Moreover, a certified reference material (human serum) was analyzed by this approach, showing an excellent accuracy (Er < 4%) and inter-device reproducibility (RSD = 1%, n = 3). Interestingly, the mu PAD array-design allowed the simultaneous analysis of different samples, improving the sample throughput (up to 5 samples in 130 min, using 100 mu L each), and the integration of calibration and analysis into the same device, simplifying the analysis without losing accuracy or sensitivity, and avoiding inter -device variability, which constituted an added value to this approach. These disposable mu PADs meet several requirements of point-of-care testing (POCT) because it is cheap, portable, easy-to-use, sensitive, and specific. Therefore, it may be an interesting way for measuring patients' serum iron levels in situ with reliability, especially, in developing countries, where the prevalence of iron deficiency and iron-deficiency anemia is higher and there are lower health resources than in developed countries., Comunidad de Madrid, Ministerio de Economía y Competitividad, Ministerio de Ciencia e Innovación
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Smartphone-based Janus micromotors strategy for motion-based detection of glutathione

  • Kaisong, Yuan
  • Cuntín Abal, Carmen|||0000-0001-5713-0971
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Herein, we describe a Janus micromotor smartphone platform for the motion-based detection of glutathione. The system compromises a universal three-dimensional (3D)-printed platform to hold a commercial smartphone, which is equipped with an external magnification optical lens (20-400x) directly attached to the camera, an adjustable sample holder to accommodate a glass slide, and a light-emitting diode (LED) source. The presence of glutathione in peroxide-rich sample media results in the decrease in the speed of 20 mu m graphene-wrapped/PtNPs Janus micromotors due to poisoning of the catalytic layer by a thiol bond formation. The speed can be correlated with the concentration of glutathione, achieving a limit of detection of 0.90 mu M, with percent recoveries and excellent selectivity under the presence of interfering amino acids and proteins. Naked-eye visualization of the speed decrease allows for the design of a test strip for fast glutathione detection (30 s), avoiding previous amplification strategies or sample preparation steps. The concept can be extended to other micromotor approaches relying on fluorescence or colorimetric detection for future multiplexed schemes., Ministerio de Ciencia e Innovación, Ministerio de Economía, Industria y Competitividad, Comunidad de Madrid
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

The rise of metal–organic framework based micromotors

  • Bujalance Fenández, Javier|||0000-0002-4582-296X
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Micromotors (MMs) are micro and nanoscale devices capable of converting energy into autonomous motion. Metal-organic frameworks (MOFs) are crystalline materials that display exceptional properties such as high porosity, internal surface areas, and high biocompatibility. As such, MOFs have been used as active materials or building blocks for MMs. In this highlight, we describe the evolution of MOF-based MMs, focusing on the last 3 years. First, we covered the main propulsion mechanisms and designs, from catalytic to fuel-free MOF-based MMs. Secondly, we discuss recent applications of new fuel-free MOFs MM to give a critical overview of the current challenges of this blooming research field. The advantages and challenges discussed provide a useful guide for the design of the next generation MOF MMs toward real-world applications., Ministerio de Ciencia e Innovación, Comunidad de Madrid
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

On-board smartphone micromotor-based fluorescence assays

  • Kaisong, Yuan
  • Asunción Nadal, Víctor de la
  • Cuntín Abal, Carmen|||0000-0001-5713-0971
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Herein, we describe the design of a portable device integrated with micromotors for real-time fluorescence sensing of (bio)markers. The system comprises a universal 3D printed platform to hold a commercial smartphone, which is equipped with an external magnification optical lens (20-400x) and tailor-made emission filters directly attached to the camera, an adjustable sample holder to accommodate a glass slide and laser excitation sources. On a first approach, we illustrate the suitability of the platform using magnetic Janus micromotors modified with fluorescent ZnS@CdxSe1-x quantum dots for real-time ON-OFF mercury detection. On a second approach, graphdiyne tubular catalytic micromotors modified with a rhodamine labelled affinity peptide are used for the OFF-ON detection of cholera toxin B. The micromotor-based smartphone for fluorescence sensing approach was compared to a high-performance optical microscope, and similar analytical features were obtained. This versatility allows for easy integration of micromotor fluorescence sensing strategies based on different propulsion mechanisms, allowing for its future use with a myriad of biomarkers and even multiplexed schemes., Comunidad de Madrid, Ministerio de Economía, Industria y Competitividad, European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Electroanalytical paper-based device for reliable detection and quantification of sugars in milk

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • Crevillen, Agustín G.
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
  • Cinti, Stefano
7 p., Knowing the level of sugars in food and beverages is essential because they are related to diseases such as diabetes, and obesity, among others. In this regard, an approach has been designed, characterized, and applied to develop the first all-in-one paper-based microfluidic analytical device for the quantification of sugars in milk samples. In particular, the powerful combination of the paper-based platform, the facile manufacturing, and the on-demand customization, allowed to obtain a stand-alone platform that was capable to store all the reagents necessary for the assay, to treating the sample by removing major interferences due to lipids and proteins, and to visualize the results in minutes. A wax-patterned chromatographic paper was finely designed to provide a reagent-free platform for the use of non-specialists applied towards the analysis of sugars? content (lactose as the main sugar). Sugars were electrochemically quantified down to 0.16 g L-1 with a repeatability of 5%. To strengthen the efficacy of the novel platform, the electrochemical paper-based analytical device has been applied to commercial milk, including skimmed, semi-skimmed, whole, and lactose-free, confirming satisfactory performance with analytical reliability. This paper-based architecture opens novel avenues for portable (bio)sensing of other relevant species, not only in the agri-food field., Comunidad de Madrid, Ministerio de Economía y Competitividad, Universidad de Nápoles Federico II
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Building HKUST-1 metal organic frameworks on a board of Cu tubular micromotors with adaptive propulsive capabilities

  • Solano Rodríguez, Enrique
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
9 p., Herein we present one step simplified synthesis of tubular Cu micromotors based on Hong Kong University of Science and Technology (HKUST-1) metal organic frameworks (MOFs). Tubular Cu/Pt, Cu/Ni and Cu/Ni/Pt micromotors prepared via template electrodeposition are smartly used as nucleation spots for the synthesis of HKUST-1 MOFs by incubating with the specific ligand, benzene-1,3,5-tricarboxylic acid, without any harsh conditions. The inner engines impart the micromotors with adaptive propulsion mechanisms for future applications: magnetic, catalytic, and hybrid magnetic and catalytic modes, reaching speeds of up to 275 mu m s-1. Furthermore, stability studies reveal a delayed degradation of the HKUST-1 MOFs in the micromotors as compared with the free MOFs. The synthesis rationale and delayed stability of the HKUST-1 MOFs in water has been exploited for compound encapsulation and controlled release, as illustrated using fluorescein as the model molecule. This approach has unlocked a new range of possibilities for future applications, offering a promising platform for the development of functional micromotors with improved capabilities., Ministerio de Ciencia, Innovación y Universidades, Fondos Europeos de Desarrollo Regional, Unión Europea, Comunidad de Madrid, Junta de Comunidades de Castilla-La Mancha, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Photoactive Au@MoS2 Micromotors for Dynamic Surface-Enhanced Raman Spectroscopy Sensing

  • Asunción Nadal, Víctor de la
  • Perales Rondon, Juan V.
  • Colina, Álvaro
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Photophoretic Au@MoS2 micromotors are used as smart mobile substrates for dynamic surface-enhanced Raman spectroscopy (SERS) sensing. The photophoretic capabilities and swarming-like propulsion of the micromotors allow for their schooling and accumulation in the measuring spot, increasing the density of SERS-active gold nanoparticles for Raman mapping and, simultaneously, the preconcentration of the target analyte. The generation of "hot-microflake spots" directly in the Raman irradiation point results in a 15-18-fold enhancement in the detection of crystal violet without the requirement for additional external sources for propulsion. Moreover, the reproducible collective micromotor motion does not depend on the exact position of the laser spot concerning individual micromotors, which greatly simplifies the experimental setup, avoiding the requirements of sophisticated equipment. The strategy was further applied for the detection of malachite green and paraquat with a good signal enhancement. The new on-the-move-based SERS strategy holds great promise for on-site detection with portable instrumentation in a myriad of environmental monitoring and clinical applications., Ministerio de Ciencia e Innovación, European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

A dual colorimetric-electrochemical microfluidic paper-based analytical device for point-of-care testing of ischemic strokes

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • Pacheco Jerez, Marta
  • Gasull, Teresa
  • Crevillen, Agustín G.
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
11 p., A novel microfluidic paper-based analytical device with dual colorimetric and electrochemical detection (dual mu PAD) was developed for the assessment of transferrin saturation (TSAT) in samples from ischemic stroke patients. TSAT was calculated from the ratio between transferrin-bound iron, which was colorimetrically measured, and the total iron-binding capacity, which was electrochemically measured. To this end, a mu PAD was smartly designed, which integrated both colorimetric and electrochemical detection reservoirs, communicating via a microchannel acting as a chemical reactor, and with preloading/storing capabilities (reagent-free device). This approach allowed the dual and simultaneous determination of both parameters, providing an improvement in the reliability of the results due to an independent signal principle and processing. The mu PADs were validated by analyzing a certified reference material, showing excellent accuracy (E-r <= 5%) and precision (RSD <= 2%). Then they were applied to the analysis of diagnosed serum samples from ischemic stroke patients. The results were compared to those provided by a free-interference method (urea-PAGE). Impressively, both methods exhibited a good correlation (r = 0.96, p < 0.05) and no significant differences were found between them (slope 1.0 +/- 0.1 and the intercept 1 +/- 4, p < 0.05), demonstrating the excellent accuracy of our approach during the analysis of complex samples from ischemic stroke patients, using just 90 mu L of clinical samples and taking less than 90 min in comparison with the 18 hours required by the urea-PAGE approach. The developed fully integrated colorimetric-electrochemical mu PAD is a promising ready to use reagent-free device for the point-of-care testing of TSAT, which can be used to assist physicians in the fast diagnosis and prognosis of ischemic strokes, where the decision-time is crucial for the patient's survival., Comunidad de Madrid, Ministerio de Economía y Competitividad, Agencia de Gestión de Ayudas Universitarias y de Investigación de Cataluña, Unión Europea
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Biotemplated Photocatalytic Micromotors for Effective Inhibition of Bacterial Growth

  • Cuntín Abal, Carmen|||0000-0001-5713-0971
  • Chávez Peraza, Miriam|||0000-0002-5512-7485
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Bacterial infections represent a major threat that can cause millions of deaths worldwide, where bacterial species can colonize and grow into highly resistant biofilms. Autonomous micromotor propulsion can improve the overall efficiency of bacterial growth inhibition versus other static processes, leading to novel methods for bacterial treatment. Here, biotemplated magnetic and photocatalytic micromotors are synthesized using E. coli and S. aureus as bacterial templates with different morphological features, such as shape and size, to obtain reproducible micromotors, followed by decoration with Fe3O4 nanoparticles for magnetic guidance into biofilms. Then, photoactive BiOCl crystals are grown on the micromotor surface for in situ photocatalytic generation of reactive oxygen species (ROS) for efficient bacterial growth inhibition. Thanks to their high photostability, E. coli@Fe3O4@BiOCl micromotors enabled controlled and efficient ROS production under sterilization conditions by using 375 nm light to trigger an oxygen vacancy generation mechanism within a biocompatible, tailored 3D-printed electrochemical cell. The (photo)electrochemical ROS generation correlated well with highly efficient bacterial growth inhibition, demonstrating the potential application of the collective dynamics of these multifunctional biotemplate-based micromotors. The concepts described here are promising for the development of future strategies against resistant bacteria by understanding the underlying processes behind them., Ministerio de Ciencia, Innovación y Universidades, Comunidad de Madrid, Junta de Comunidades de Castilla la Mancha, Universidad de Alcalá, European Union
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Prussian Blue/Chitosan Micromotors with Intrinsic Enzyme-like Activity for (bio)-Sensing Assays

  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
  • Molinero Fernández, Águeda
  • María Hormigos, Roberto|||0000-0001-8002-3998
  • López Gil, Miguel Ángel|||0000-0003-3711-010X
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
Prussian Blue (PB)/chitosan enzyme mimetic tubular micromotors are used here for on-the-fly (bio)-sensing assays. The micromotors are easily prepared by direct deposition of chitosan into the pores of a membrane template and in situ PB synthesis during hydrogel deposition. Under judicious pH control, PB micromotors display enzyme mimetic capabilities with three key functions on board: the autonomous oxygen bubble propulsion (with PB acting as a catalase mimic for hydrogen peroxide decomposition), 3,3',5,5'-tetramethylbenzidine (TMB) oxidation (with PB acting as a peroxidase mimic for analyte detection), and as a magnetic material (to simplify the (bio)-sensing steps). In connection with chitosan capabilities, these unique enzyme mimetic micromotors are further functionalized with acetylthiocholinesterase enzyme (ATChE) to be explored in fast inhibition assays (20 min) for the colorimetric determination of the nerve agent neostigmine, with excellent analytical performance in terms of quantification limit (0.30 mu M) and concentration linear range (up to 500 mu M), without compromising efficient micromotor propulsion. The new concept illustrated holds considerable potential for a myriad of (bio)-sensing applications, including forensics, where this conceptual approach remains to be explored. Micromotor-based tests to be used in crime scenes are also envisioned due to the reliable neostigmine determination in unpretreated samples., Ministerio de Economía, Industria y Competitividad, Comunidad de Madrid, European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Paper-based analytical devices for accurate assessment of transferrin saturation in diagnosed clinical samples from ischemic stroke patients

  • Dortez Herranz, Silvia|||0000-0002-1999-5605
  • DeGregorio Rocasolano, Núria
  • Millán, Mònica
  • Gasull, Teresa
  • Crevillen, Agustín G.
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
7 p., For the first time, a paper-based analytical device (PAD) was developed for the assessment of transferrin saturation (TSAT), which is defined as the ratio between iron bound to transferrin (Tf) and the total iron-binding capacity (TIBC) of Tf. Both parameters were simultaneously measured on the same PAD using ferrozine as a chromophore and a smartphone as the color reader. To this end, Tf was first isolated from serum using anti-Tf immunomagnetic beads to ensure that only the Tf-bound iron was measured, improving the selectivity and accuracy of TSAT assessment. To demonstrate the practical utility of the device, it was validated by analyzing a certified reference material, showing excellent accuracy (Er < 4%) and good precision (RSD ? 6%). Finally, 18 diagnosed serum samples from ischemic stroke patients were analyzed by this approach, and the results were compared with those obtained by urea-PAGE, showing not only an excellent correlation (r = 0.93, p < 0.05) but that the PAD approach has become statistically identical to the free-interference urea-PAGE. In comparison with the slow, tedious, and non-miniaturized-PAGE, this PAD approach exhibited attractive characteristics such as low cost, disposability, and connectivity, showing great potential for future point-of-care testing, especially in developing countries and/or remote areas, where access to medical or clinical facilities is limited., Comunidad de Madrid, Ministerio de Economía y Competitividad, Ministerio de Ciencia e Innovación, Agencia de Gestión de Ayudas Universitarias y de Investigación de Cataluña, Unión Europea
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

On the Move-Sensitive Fluorescent Aptassay on Board Catalytic Micromotors for the Determination of Interleukin-6 in Ultra-Low Serum Volumes for Neonatal Sepsis Diagnostics

  • Gordón Pidal, José María|||0000-0001-8465-3268
  • Arruza Gómez, Luis
  • Ibáñez, María Dolores
  • Moreno Guzmán, María
  • López Gil, Miguel Ángel|||0000-0003-3711-010X
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
A graphene oxide/nickel/platinum nanoparticle micromotor (MM)-based fluorescent aptassay is proposed to determine interleukin-6 (IL-6) in serum samples from low-birth-weight infants (gestational age of less than 32 weeks and birthweight below 1000 g) with sepsis suspicion. In this kind of patients, IL-6 has demonstrated good sensitivity and specificity for the diagnosis of sepsis, both for early and late onset sepsis. The approach was based on the adsorption of the aptamer for IL-6 tagged with 6-FAM as a fluorescent label (AptIL?6, ?em = 520 nm) on the graphene oxide external layer (MMGO?AptIL?6) inducing fluorescence quenching (OFF state) and a subsequent on-the-move affinity recognition of IL-6 from AptIL?6 (IL-6?AptIL?6 complex) recovering the fluorescence (ON state). An aptamer against IL-6 was selected and developed by the systematic evolution of ligands by exponential enrichment technology. This approach displayed a suitable linear range of 0.07?1000 pg mL?1 (r = 0.995) covering the cut-off and clinical practice levels, allowing direct determination without any dilution and simplifying the analysis as well as exhibiting an excellent sensitivity (LOD = 0.02 pg mL?1) in ultralow volumes of diagnostic clinical samples (2 ?L). A high agreement between IL-6 levels obtained from our MM-based approach and the method used by the Hospital was obtained (relative error < 3%). The MM-based aptassay is competitive in comparison with that of the Hospital, in terms of a significant reduction of the sample volume (15 times less) and enhanced sensitivity, employing similar analysis times. These results position MM technology with enough potential to achieve high sensitivities in low sample volumes, opening new avenues in diagnosis based on low sample volumes., Ministerio de Ciencia e Innovación, Comunidad de Madrid, European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Transition metal dichalcogenide micromotors with programmable photophoretic swarming motion

  • Asunción Nadal, Víctor de la
  • Rojas Tizón, José Daniel|||0000-0002-4404-4668
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Herein we report the light-triggered photophoretic motion of WS2 micromotors. The micromotors are prepared by liquid-phase exfoliation of pristine WS2 in water, resulting in a layered material with high photoconversion capability. Under electromagnetic irradiation in the UV or VIS range, the micromotors exhibit a positive photophoretic motion and swarming-like schooling behavior. The light-induced heating of the prepared micromotors is studied and computational fluid dynamics simulations are considered to characterize the photophoretic propulsion mechanism. The novel micromotors described here are capable of performing a collective motion without the need for surfactants, fuels, or other reagents, reaching velocities of up to 6000 mu m s(-1). To date, this represents the fastest light-driven micromotor platform, paving the way for novel cutting-edge applications., Ministerio de Economía, Industria y Competitividad, Ministerio de Ciencia e Innovación, Comunidad de Madrid, European Commission
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Affinity peptide-based magnetic micromotors for rapid, selective, ultra-sensitive, and reliable quantification of SARS-CoV-2 spike protein in microliter-scale nasopharyngeal and plasma samples from infected patients

  • Rodríguez Castillo, Alberto
  • Postigo, Tamara
  • Pérez García, Felipe|||0000-0002-4885-4334
  • Bermejo, Jesús
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Monitoring respiratory viruses is paramount to reducing the spread of the virus and associated costs, especially during the winter months. Here, we present magnetically propelled MoS2/Ni micromotors modified with a rhodamine B-labelled peptide that binds to the receptor-binding domain (RBD) on the S1 subunit of the spike protein (S). The approach uses an "on-the-fly" OFF-ON fluorescence method to detect the SARS-CoV-2 virus in two types of samples: nasopharyngeal and plasma samples, both types previously tested by molecular methods, and plasma samples additionally analyzed by serological assays. The micromotors move through the sample, inducing enhanced fluid mixing and increasing the number of peptide-spike protein biorecognition events, yielding an efficient operation using just 1 ?L of sample. The adsorbed peptide on MoS2 (OFF state) desorbs from the micromotors, due to interaction rhodamine B-labelled peptide-spike protein resulting in an increase in targetdependent fluorescence intensity in the solution measured using fluorescence microscopy (ON state). The approach takes just 1 min, displaying a linear range of 0.006?50 ng/mL with an excellent limit of detection of 1.8 pg/mL. The good agreement between the main infection indicators from nasopharyngeal and plasma samples, as measured by molecular and serological tests in the hospital, and the protein S concentration, as measured by our micromotor approach, demonstrates the applicability of the method for the rapid diagnosis of respiratory infections, opening new avenues for the diagnosis of respiratory infections. While the potency of the micromotor approach is demonstrated here, novel integration approaches are also envisioned in the near future., Ministerio de Ciencia, Innovación y Universidades, Junta de Comunidades de Castilla-La Mancha, Universidad de Alcalá
e_Buah Biblioteca Digital Universidad de Alcalá
Publication Artículo científico (JournalArticle)

Cyclo-Octasulfur Crystals as Light-Controlled Molecular Muscles

  • Solano Rodríguez, Enrique
  • Sun, Qi
  • Bredás, Jean-Luc
  • Coropceanu, Veaceslav
  • Jurado Sánchez, Beatriz|||0000-0002-6584-1949
  • Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Here, we describe the synthesis and photo-responsive properties of 2D cyclo-octasulfur microcrystals (alpha-S8 MCs), produced using a quick, simple, cost-effective, and environmentally friendly hydrothermal method. Controlled 385-nm irradiation of these crystals induces an immediate, reversible, and sustained bending effect. The time required for the crystals to return to their initial shape is significantly reduced when exposed to 475-nm light, completing the entire excitation-relaxation cycle in less than 2 s. Moreover, this process can be repeated up to 50 times as long as the crystals remain in water. The dependence of recovery time on light wavelength is rationalized qualitatively via highly correlated quantum-chemical calculations of the absorption spectra of S8 chains. The underlying mechanism involves a combination of ring-to-chain and chain-to-ring transformations: the breaking of alpha-S8 rings by 385-nm radiation induces bending in the alpha-S8 MCs, while the excitation of the chains with 475-nm light facilitates an accelerated recovery process, allowing the S8 molecules to swiftly regain their ring shape. Thus, our study demonstrates that alpha-S8 MCs represent intelligent actuators as light-controlled molecular muscles with the simplest inorganic composition reported to date., Ministerio de Ciencia, Innovación y Universidades, European Commision