Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 286
Encontrada(s) 3 página(s)

BULERIA. Repositorio Institucional de la Universidad de León
Publication Artículo científico (JournalArticle)

Diffeomorphic transforms for data augmentation of highly variable shape and texture objects

  • Vállez Enano, Noelia
  • Bueno García, María Gloria
  • Déniz Suárez, Óscar
  • Blanco Lanza, Saúl
[EN] Background and objective: Training a deep convolutional neural network (CNN) for automatic image classification requires a large database with images of labeled samples. However, in some applications such as biology and medicine only a few experts can correctly categorize each sample. Experts are able to identify small changes in shape and texture which go unnoticed by untrained people, as well as distinguish between objects in the same class that present drastically different shapes and textures. This means that currently available databases are too small and not suitable to train deep learning models from scratch. To deal with this problem, data augmentation techniques are commonly used to increase the dataset size. However, typical data augmentation methods introduce artifacts or apply distortions to the original image, which instead of creating new realistic samples, obtain basic spatial variations of the original ones. Methods: We propose a novel data augmentation procedure which generates new realistic samples, by combining two samples that belong to the same class. Although the idea behind the method described in this paper is to mimic the variations that diatoms experience in different stages of their life cycle, it has also been demonstrated in glomeruli and pollen identification problems. This new data augmentation procedure is based on morphing and image registration methods that perform diffeomorphic transformations. Results: The proposed technique achieves an increase in accuracy over existing techniques of 0.47%, 1.47%, and 0.23% for diatom, glomeruli and pollen problems respectively. Conclusions: For the Diatom dataset, the method is able to simulate the shape changes in different diatom life cycle stages, and thus, images generated resemble newly acquired samples with intermediate shapes. In fact, the other methods compared obtained worse results than those which were not using data augmentation. For the Glomeruli dataset, the method is able to add new samples with different shapes and degrees of sclerosis (through different textures). This is the case where our proposed DA method is more beneficial, when objects highly differ in both shape and texture. Finally, for the Pollen dataset, since there are only small variations between samples in a few classes and this dataset has other features such as noise which are likely to benefit other existing DA techniques, the method still shows an improvement of the results, SI, The authors acknowledge financial support of the Spanish Government and Junta de Comunidades de Castilla-La Mancha under projects AQUALITAS (Ref. CTM2014-51907-C2-R-MINECO), HYPERDEEP (Ref. SBPLY/19/180501/000273), and APRENDAMOS (Ref. SBPLY/17/180501/000543). They would also like to extend the acknowledgment to technicians Enrique Cepeda and Jesus Diaz for their help in running some experiments
Docta Complutense
Publication Artículo científico (JournalArticle)

The challenge of managing threatened invasive species at a continental scale

  • Baquero Noriega, Rocío Aranzazu
  • Oficialdegui, Francisco Javier
  • Ayllón Fernández, Daniel
  • Gómez Nicola, María Gracia
The European Union's (EU) environmental legislation establishes common measures to prevent the entry and spread of invasive non-native species and to minimize their impacts. However, species that are native to at least one member state but non-native and potentially invasive in others (NPIS) are in limbo because they are neither legally regulated at the EU level nor in most member states. We used the Communication and Information Resource Centre for Administrations, Businesses and Citizens (CIRCABC) raw data on NPIS (317 taxa) to analyze their distribution across the EU and identify which biogeographical regions are the main sources of invasions. We additionally evaluated the conservation challenge posed by NPIS that are threatened within their native ranges. We performed a pairwise analysis summarizing the number of species that are native to a given member state but non-native to another and vice versa. Although distribution patterns of NPIS varied across taxa groups, overall, southern and central EU countries were both donors and recipients of NPIS. Eastern countries were mainly a source, and western and northern countries mostly received NPIS. Around 27% of NPIS were threatened in some of their EU native ranges, which is a challenge for conservation and management because some of them have serious negative effects on European biodiversity, but hitherto remain outside the scope of the EU regulation of invasive non-native species. This highlights an unresolved paradox because efforts to manage species as invasive conflict with efforts to protect them as threatened within the same territory.
Docta Complutense
Publication Artículo científico (JournalArticle)

Frequent Parasitism of Apis mellifera by Trypanosomatids in Geographically Isolated Areas with Restricted Beekeeping Movements

  • Aguado López, Daniel
  • Bartolomé, Carolina
  • Lopes, Ana Rita
  • Henriques, Dora
  • Segura, Sara Kafafi
  • Maside, Xulio
  • Pinto, M. Alice
  • Higes, Mariano
  • Martín Hernández, Raquel
Trypanosomatids form a group of high prevalence protozoa that parasitise honey bees, with Lotmaria passim as the predominant species worldwide. However, the knowledge about the ecology of trypanosomatids in isolated areas is limited. The Portuguese archipelagos of Madeira and Azores provide an interesting setting to investigate these parasites because of their geographic isolation, and because they harbour honey bee populations devoid of two major enemies: Varroa destructor and Nosema ceranae. Hence, a total of 661 honey bee colonies from Madeira and the Azores were analysed using different molecular techniques, through which we found a high prevalence of trypanosomatids despite the isolation of these islands. L. passim was the predominant species and, in most colonies, was the only one found, even on islands free of V. destructor and/or N. ceranae with severe restrictions on colony movements to prevent the spread of them. However, islands with V. destructor had a significantly higher prevalence of L. passim and, conversely, islands with N. ceranae did not shown any significant correlation with the trypanosomatid. Crithidia bombi was detected in Madeira and on three islands of the Azores, almost always coincident with L. passim. By contrast, Crithidia mellificae was not detected in any sample. A high-throughput sequencing analysis distinguished two main haplotypes of L. passim, which accounted for 98% of the total sequence reads. This work suggests that L. passim and C. bombi are parasites that have been associated with honey bees predating the spread of V. destructor and N. ceranae.
RIUMA. Repositorio Institucional de la Universidad de Málaga
Publication Artículo científico (JournalArticle)

West Nile virus unmasked: from gene variability to future challenges

  • Prieto-Vega, Samuel
  • Berzal Herranz, Alfredo
  • Garrido, Juan José
  • Arias, Armando
  • Grande-Pérez, Ana
  • Fernández-Escamilla, Ana María
  • Montoya, María
El virus del Nilo Occidental (WNV) es un ortoflavivirus transmitido por mosquitos cuyo ciclo de transmisión implica aves como reservorios y artrópodos vectores. Aunque no existen cifras globales exactas, estimaciones basadas en seroprevalencia indican entre 4 y 16 millones de infecciones al año. Con una mortalidad aproximada del 6–7% en los casos notificados, el WNV representa un desafío relevante para la salud pública. Esta revisión resume la biología molecular del WNV, abarcando la organización del genoma, la maduración proteica, los mecanismos de replicación y el papel de las regiones no traducidas y de las modificaciones postraduccionales en la adaptación viral. Se destaca la variabilidad genética intrahospedador y la naturaleza de cuasiespecie como elementos clave en la evasión inmunitaria y la evolución del virus. Asimismo, se analizan los factores ecológicos y epidemiológicos que influyen en su expansión, especialmente en el contexto del cambio climático y la alteración de la distribución de vectores. La revisión aborda también las manifestaciones clínicas, la patogénesis, los métodos diagnósticos y las estrategias terapéuticas actuales. Se describen enfoques emergentes de prevención y control, como la vigilancia entomológica, el desarrollo de vacunas y nuevos candidatos antivirales, incluidos péptidos dirigidos, anticuerpos y mutagénesis letal. El trabajo subraya la necesidad de sistemas de vigilancia integrados bajo el enfoque One Health y de acelerar el desarrollo de vacunas para reducir el riesgo de futuros brotes a nivel global., West Nile virus (WNV) is a mosquito-borne orthoflavivirus whose transmission cycle involves birds as reservoirs and arthropod vectors. Although precise global figures are lacking, seroprevalence-based estimates suggest between 4 and 16 million infections annually. With an approximate mortality of 6–7% among reported cases, WNV remains a significant public health challenge. This review summarizes the molecular biology of WNV, including genome organization, protein maturation, replication mechanisms, and the roles of untranslated regions and post-translational modifications in viral adaptation. Intrahost genetic variability and the quasispecies nature of WNV are highlighted as key factors in immune evasion and viral evolution. The review also examines ecological and epidemiological drivers of WNV spread, particularly in the context of climate change and shifting vector distributions. Clinical manifestations, pathogenesis, diagnostic methods, and current therapeutic strategies are discussed. Emerging approaches for prevention and control are addressed, including entomological surveillance, vaccine development, and novel antiviral candidates such as targeted peptides, antibodies, and lethal mutagenesis. The work underscores the need for integrated One Health surveillance systems and accelerated vaccine development to mitigate the risk of future global outbreaks., NextGenerationEU (Regulation EU 2020/2094), through CSIC’s Global Health Platform (PTI+ Salud Global), Spanish Ministry of Science, Spanish Ministry of Universities, Generalitat Valenciana, Ministerio de Ciencia, Innovación y Universidades and FEDER (EU), Junta de Comunidades de Castilla-La Mancha (JCCM), University of Castilla La Mancha (UCLM), Regional Government of Andalusia (Consejerıá de Universidad, Investigación e Innovación), Spain, CSIC Open Access Publication Support Initiative (PROA) through its Unit of Information Resources for Research (URICI)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Short-Time Estimation of Fractionation in Atrial Fibrillation with Coarse-Grained Correlation Dimension for Mapping the Atrial Substrate

  • Vraka, Aikaterini
  • Hornero, Fernando
  • Bertomeu-Gonzalez, Vicente
  • Osca, Joaquin
  • Alcaraz, Raul
  • Rieta, J J|||0000-0002-3364-6380
[EN] Atrial ¿brillation (AF) is currently the most common cardiac arrhythmia, with catheter ablation (CA) of the pulmonary veins (PV) being its ¿rst line therapy. Ablation of complex fractionated atrial electrograms (CFAEs) outside the PVs has demonstrated improved long-term results, but their identi¿cation requires a reliable electrogram (EGM) fractionation estimator. This study proposes a technique aimed to assist CA procedures under real-time settings. The method has been tested on three groups of recordings: Group 1 consisted of 24 highly representative EGMs, eight of each belonging to a different AF Type. Group 2 contained the entire dataset of 119 EGMs, whereas Group 3 contained 20 pseudo-real EGMs of the special Type IV AF. Coarse-grained correlation dimension (CGCD) was computed at epochs of 1 s duration, obtaining a classi¿cation accuracy of 100% in Group 1 and 84.0¿85.7% in Group 2, using 10-fold cross-validation. The receiver operating characteristics (ROC) analysis for highly fractionated EGMs, showed 100% speci¿city and sensitivity in Group 1 and 87.5% speci¿city and 93.6% sensitivity in Group 2. In addition, 100% of the pseudo-real EGMs were correctly identi¿ed as Type IV AF. This method can consistently express the fractionation level of AF EGMs and provides better performance than previous works. Its ability to compute fractionation in short-time can agilely detect sudden changes of AF Types and could be used for mapping the atrial substrate, thus assisting CA procedures under real-time settings for atrial substrate modi¿cation., This research has been supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from JCCM and AICO/2019/036 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Atrial Fibrillation Surgical Ablation Long-term Outcome Prediction Just with One Lead of the Preoperative Surface Electrocardiogram

  • García, Manuel
  • Escribano, Pilar
  • Ródenas, Juan
  • Martínez-Iniesta, Miguel
  • Hornero, Fernando
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] To revert atrial fibrillation (AF) in patients requiring concomitant open-heart surgery, surgical ablation (SA) is one of the most effective procedures. However, this intervention is as- sociated with major side effects. Considering this limitation together with the benefits of anticipating antiarrhythmic treatment decisions, preoperative prediction of long-term outcome of SA is an interesting challenge. In the present work a novel algorithm to anticipate SA outcome after a follow-up of 12 months is introduced by just analyzing one lead from a preoperative electrocardiogram (ECG). Precisely, fibrillatory waves reflected on lead V1 are extracted using a QRST cancellation method. The obtained signal is divided into 1 s-length segments, which are decomposed into 8 time scales by making use a Wavelet transform. Finally, relative wavelet energy for each segment and scale is computed and the standard deviation of the time series for the 7th scale is obtained as a measure of organization of the fibrillatory waves. This index obtained statistically significant differences between the patients who maintained sinus rhythm and relapsed to AF during the follow-up. Moreover, it also yielded a discriminant ability about 75%, thus improving between 13 and 29% the one showed by other well-established parameters., This research has been supported by grants DPI2017-83952- C3 from MINECO/AEI/FEDER EU, SBPLY/17/ 180501/000411 from Junta de Comunidades de Castilla-la Mancha, and AICO/2019/036 from Generalitat Valenciana. Moreover, Pilar Escribano holds a graduate research scholarship from University of Castilla-La Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Microwave-assisted functionalization of carbon nanohorns with oligothiophene units with SERS activity

  • Iglesias, Daniel
  • Guerra, Javier
  • González-Cano, Rafael C.
  • Lopez Navarrete, Juan T.
  • Ruiz Delgado, M. Carmen
  • Vázquez, Ester
  • Herrero, M. Antonia
  • Lucío, María Isabel|||0000-0001-7404-352X
[EN] Carbon nanohorns have been functionalized with oligothiophene unitsviathe 1,3-dipolar cycloaddition reaction under microwave irradiation and solvent-free conditions. A dramatic Raman enhancement was found for one of the synthesized derivatives. Experimental andin silicostudies helped to understand the enhancement, attributed to the modification of electromagnetic fields upon functionalization at the tip of the nanostructures., This work was supported by the Iberdrola Foundation (CONV120313), the Spanish Ministerio de Economia y Competitividad (CTQ2017-88158-R), the Junta de Comunidades de Castilla-La Mancha (SBPLY/17/180501/000204) and FEDER-JCCM (UNCM13-1E-1663). The work at the University of Malaga was funded by the MICINN (PID2019-110305GB-I00) and Junta de Andalucia (P09FQM-4708) projects. M. I. L. acknowledges MINECO for her Juan de la Cierva-formacion grant (FJCI-2016-29593). The authors acknowledge the computer resources, technical expertise, and assistance provided by the Supercomputing and Bioinformatics centre of the University of Malaga.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Study on the Stability of CFAEs to Characterize the Atrial Substrate in Atrial Fibrillation

  • Finotti, Emanuela
  • Ciaccio, Edward J.
  • Garan, Hasan
  • Hornero, Fernando
  • Alcaraz, Raul
  • Rieta, J J|||0000-0002-3364-6380
[EN] A variety of indexes has been applied to complex fractionated atrial electrograms (CFAEs) of atrial fibrillation (AF) aimed at characterizing the atrial substrate. However, often the reported results miss the assessment of intra-recording and intra-patient stability of the analyzed data, as well as CFAEs signal quality. This work introduces a study in which Determinism (DET) of Recurrence Quantification Analysis (RQA) and Sample Entropy (SE) have been applied to assess intra-recording and intrapatient stability of 1, 2 and 4 s-length segments CFAEs recorded from patients with paroxysmal and persistent AF using the coefficient of variation (CV). Furthermore, the analyses verified changes introduced by discarding artifacted and noisy CFAE segments. The intra-recording analysis pointed out that discarding segments provoked a significant variation of CV(%) in any segment length both for DET and SE, with deeper decreases for longer segments. Intra-patient stability provided large variations in CV(%) for DET and even bigger for SE at any segment length. In this case discarding segments was useless and CV provided limited variations. Kruskal-Wallis test revealed significant differences in DET and SE values among channels, independently from the discarding process., Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2019/036 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Improved Hypertension Risk Assessment with Photoplethysmographic Recordings Combining Deep Learning and Calibration

  • Cano-Serrano, Jesús
  • Bertomeu-González, Vicente
  • Fácila, Lorenzo
  • Hornenro, Fernando
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Hypertension, a primary risk factor for various cardiovascular diseases, is a global health concern. Early identification and effective management of hypertensive individuals are vital for reducing associated health risks. This study explores the potential of deep learning (DL) techniques, specifically GoogLeNet, ResNet-18, and ResNet-50, for discriminating between normotensive (NTS) and hypertensive (HTS) individuals using photoplethysmographic (PPG) recordings. The research assesses the impact of calibration at different time intervals between measurements, considering intervals less than 1 h, 1-6 h, 6-24 h, and over 24 h. Results indicate that calibration is most effective when measurements are closely spaced, with an accuracy exceeding 90% in all the DL strategies tested. For calibration intervals below 1 h, ResNet-18 achieved the highest accuracy (93.32%), sensitivity (84.09%), specificity (97.30%), and F1-score (88.36%). As the time interval between calibration and test measurements increased, classification performance gradually declined. For intervals exceeding 6 h, accuracy dropped below 81% but with all models maintaining accuracy above 71% even for intervals above 24 h. This study provides valuable insights into the feasibility of using DL for hypertension risk assessment, particularly through PPG recordings. It demonstrates that closely spaced calibration measurements can lead to highly accurate classification, emphasizing the potential for real-time applications. These findings may pave the way for advanced, non-invasive, and continuous blood pressure monitoring methods that are both efficient and reliable., This research has received financial support from public grants PID2021-123804OB-I00, PID2021-00X128525-IV0 and TED2021-130935B-I00 of the Spanish Government, jointly with the European Regional Development Fund (EU), SBPLY/17/180501/000411 and SBPLY/21/180501/000186 from Junta de Comunidades de Castilla-La Mancha, and AICO/2021/286 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Assisting Electrophysiological Substrate Quantification in Atrial Fibrillation Ablation

  • Vraka, Aikaterini
  • Hornero, Fernando
  • Osca, Joaquín
  • Faes, Luca
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Catheter ablation (CA) is the most popular treatment of atrial fibrillation (AF) with good results in paroxysmal AF, while its efficiency is significantly reduced in persistent AF. With the equipment used for CA strongly depending on electro-gram (EGM) fractionation quantification, the use of a reliable fractionation estimator is crucial to reduce the high recurrence rates in persistent AF. This work introduces a non-linear EGM fractionation quantification technique, which is based on coarse-grained correlation dimension (CGCD) computed over epochs of 1 second. Recordings were firstly normalized, denoised and lowpass filtered. The final CGCD value was calculated by the median CGCD value of all the epochs that a recording consisted of. Results were evaluated on three groups. Groups 1 and 2 contained 24 high-quality and 119 mid-range EGMs, respectively, manually pre-classified by AF types following Wells' criteria, then classified according to their CGCD values. 20 pseudo-real Type IV EGMs formed group 3 that was also automatically classified by AF type. In Groups 1 and 2, classification accuracy was 100% and 84-85.7%, respectively, using 10-fold cross-validation. The receiver-operating characteristics (ROC) analysis for highly fractionated EGMs, showed 100% specificity and sensitivity in Group 1 and 87.5% specificity and 93.6% sensitivity in Group 2. CGCD was always consistent with the fractionation degree of EGMs. 100% of the EGMs in Group 3 were correctly identified as Type IV AF. High accuracy results indicate that the method can estimate precisely the AF Type and detect the existence of AF Type IV cases. Both things are crucial in assisting improved substrate mapping during CA procedures of persistent AF., Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2019/036 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Interrogating the Behaviour of a Styryl Dye Interacting with a Mesoscopic 2D-MOF and Its Luminescent Vapochromic Sensing

  • di Nunzio, Maria Rosaria
  • Gutiérrez, Mario
  • Moreno, José María
  • Douhal, Abderrazzak
  • Corma Canós, Avelino|||0000-0002-2232-3527
  • Díaz, Urbano|||0000-0003-1472-8724
[EN] In this contribution, we report on the solid-state-photodynamical properties and further applications of a low dimensional composite material composed by the luminescent trans-4-(dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran (DCM) dye interacting with a two-dimensional-metal organic framework (2D-MOF), Al-ITQ-HB. Three different samples with increasing concentration of DCM are synthesized and characterized. The broad UV-visible absorption spectra of the DCM/Al-ITQ-HB composites reflect the presence of different species of DCM molecules (monomers and aggregates). In contrast, the emission spectra are narrower and exhibit a bathochromic shift upon increasing the DCM concentration, in agreeance with the formation of adsorbed aggregates. Time-resolved picosecond (ps)-experiments reveal multi-exponential behaviors of the excited composites, further confirming the heterogeneous nature of the samples. Remarkably, DCM/Al-ITQ-HB fluorescence is sensitive to vapors of electron donor aromatic amine compounds like aniline, methylaniline, and benzylamine due to a H-bonding-induced electron transfer (ET) process from the analyte to the surface-adsorbed DCM. These findings bring new insights on the photobehavior of a well-known dye when interacting with a 2D-MOF and its possible application in sensing aniline derivatives., This publication is part of the I+D+I projects with references PID2020-116519RB-I00, MAT2017-86532-R, PID2020-112590GB-C21/AEI/10.13039/501100011033. This work was also supported by the JCCM and the UCLM through projects SBPLY/19/180501/000212 and 2020-GRIN-28929 (Feder), respectively. M.G. also thanks the EU for the financial support through Fondo Social Europeo Plus (FSE+).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A Novel Signal Restoration Method of Noisy Photoplethysmograms for Uninterrupted Health Monitoring

  • Vraka, Aikaterini
  • Zangróniz, Roberto
  • Quesada, Aurelio
  • Hornero, Fernando
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Health-tracking from photoplethysmography (PPG) signals is significantly hindered by motion artifacts (MAs). Although many algorithms exist to detect MAs, the corrupted signal often remains unexploited. This work introduces a novel method able to reconstruct noisy PPGs and facilitate uninterrupted health monitoring. The algorithm starts with spectral-based MA detection, followed by signal reconstruction by using the morphological and heart-rate variability information from the clean segments adjacent to noise. The algorithm was tested on (a) 30 noisy PPGs of a maximum 20 s noise duration and (b) 28 originally clean PPGs, after noise addition (2-120 s) (1) with and (2) without cancellation of the corresponding clean segment. Sampling frequency was 250 Hz after resampling. Noise detection was evaluated by means of accuracy, sensitivity, and specificity. For the evaluation of signal reconstruction, the heart-rate (HR) was compared via Pearson correlation (PC) and absolute error (a) between ECGs and reconstructed PPGs and (b) between original and reconstructed PPGs. Bland-Altman (BA) analysis for the differences in HR estimation on original and reconstructed segments of (b) was also performed. Noise detection accuracy was 90.91% for (a) and 99.38-100% for (b). For the PPG reconstruction, HR showed 99.31% correlation in (a) and >90% for all noise lengths in (b). Mean absolute error was 1.59 bpm for (a) and 1.26-1.82 bpm for (b). BA analysis indicated that, in most cases, 90% or more of the recordings fall within the confidence interval, regardless of the noise length. Optimal performance is achieved even for signals of noise up to 2 min, allowing for the utilization and further analysis of recordings that would otherwise be discarded. Thereby, the algorithm can be implemented in monitoring devices, assisting in uninterrupted health-tracking., This research has received financial support from public grants PID2021-123804OB-I00, PID2021-00X128525-IV0, and TED2021-130935B-I00 of the Spanish Government, 10.13039/501100011033 jointly with the European Regional Development Fund (EU), SBPLY/17/180501/000411 and SBPLY/21/180501/000186 from Junta de Comunidades de Castilla-La Mancha, and AICO/2021/286 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Are Coronary Sinus Features Reflecting the Effect of Catheter Ablation of Atrial Fibrillation as P-waves Do?

  • Vraka, Aikaterini
  • Bertomeu-González, Vicente
  • Hornenro, Fernando
  • Langley, Philip
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Atrial substrate alteration due to catheter ablation (CA) of atrial fibrillation (AF) is primarily assessed from P-waves. Nonetheless, how CA affects critical structures is ignored. The aim of the current study is to investigate if CA effect on CS, the principal CA reference, is related to that observed from P-waves analysis. Five-minute lead II and bipolar CS recordings of 29 paroxysmal AF patients were obtained before, during and after CA. Duration, amplitude, area and heart-rate (HR) variability (HRV) features were calculated for P-waves and local activation waves (LAWs). Normalization mitigated the effect of HR fluctuations. Linear correlations between each P-wave and LAW were tested with linear regression (LR) and Pearson correlation (PC) and nonlinear correlations with cross-quadratic sample entropy (CQSE). Correlation between the CA effect on P-waves and LAWs was investigated with PC. Negligent statistical correlations were found by PC and LR for amplitude and area (¿3.30%< corr < +18.36%, p < 0.0142). After normalization, correlation in duration increased from non-significant to significant and from low to moderate (up to 47.25%, p < 0.0001). CQSE values were from 0.6 to 1.2. The effect of CA on P-waves and LAWs duration showed a moderate/high concordance after normalization (from 50% to 89%, p < 0.0210) and a highly tuned HRV (> 90%, p < 0.0297). Apart from HRV, no significant correlations between CS LAWs and P-waves have been found. HR fluctuations mask any possible tuning and normalization should be applied prior to the analysis., Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2021/286 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Is Short-Term Heart Rate Variability Good Enough to Predict Vascular Events in Hypertensive Patients?

  • Tornero, Roberto
  • Fácila, Lorenzo
  • Bertomeu-González, Vicente
  • Zangróniz, Roberto
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Vascular events are the main cause of premature death and disability in the developed countries, where there is great interest in the development of computational tools for their early detection. A very relevant variable for their study is the heart rate, that can be analyzed through heart rate variability (HRV). Furthermore, high blood pressure is an important risk factor for most cardiovascular diseases. In fact, small reductions in blood pressure are known to markedly reduce cardiovascular morbidity and mortality. This study evaluates the predictive value of short-term HRV (STHRV) by developing models based on data mining algorithms to stratify the risk of vascular events from hypertensive patients. For this specific framework, the performance of various machine learning models (Random Forest, Support Vector Machines, Gaussian Naive Bayes, K-N Nearest Neighbours and Logistic regression), trained with different time lengths of 5, 30 and 60 minutes of HRV features during sleep stage was compared. The analyzed HRV parameters were associated to time, frequency and nonlinear features. A total of 139 Holter recordings from hypertensive patients of whom 17 developed a vascular event were analyzed. Results indicated that classification models developed using STHRV, with only 5 minutes length, provided similar or even better results than those developed with longer time series. Furthermore, the STHRV models provided a higher sensitivity and a slightly higher F1 score. The best one, based on Support Vector Machines, yielded 88.2% sensitivity and 75% F1 score. Thus, this research suggests the feasibility of STHRV analysis for risk stratification of hypertensive patients to anticipate serious vascular events., Research supported by grants DPI2017¿83952¿C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2021/286 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

An Optical Engine Used as a Physical Model for Studies of the Combustion Process Applying a Two-Color Pyrometry Technique

  • Corral-Gómez, Lis
  • Armas, Octavio
  • Soriano, José A.
  • Pastor, José V.|||0000-0003-4113-4681
  • García-Oliver, José M|||0000-0002-2676-9681
  • Micó, Carlos|||0000-0001-5787-6212
[EN] This work describes an experimental installation for the investigation of the combustion and injection processes. This installation is based on a two-stroke direct injection diesel engine with a total displacement of 3 L and a cylinder head equipped with three quartz windows. The windows are optical accesses that allow studying the process of injection, the atomization and evaporation of the fuel jet in an inert atmosphere (nitrogen), and the combustion process in a reactive atmosphere (ambient air). Additionally, the application of a two-color pyrometry technique to measure soot formation in this facility is presented. A methodological study is carried out regarding the influence of the dynamic range of the detectors and the wavelengths used. Maps of KL2C, flame temperature, and error probability are presented. The use of cameras with high dynamic range provides better results since the system seems to be less sensitive to measurement noise, and fewer points are obtained with a non-physical solution. Moreover, an appropriate combination of interference filters can improve the reliability of the solution. The greater the difference between the wavelengths of both interference filters, the fewer points with a non-physical solution, which improves the reliability of results., This research was funded by Castilla-La Mancha Government to the project grant number ASUAV Ref. SBPLY/19/180501/000116.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Automatic generation of as-is BEM models of buildings

  • Adan, A.
  • Vilar-Abad, Alejandro
  • Ramón-Constantí, Amanda|||0000-0001-7084-8275
  • Vivancos, José-Luis|||0000-0002-8524-5466
  • Aparicio Fernandez, Carolina Sabina|||0000-0003-0197-9452
[EN] This paper shows a method with which to create a proprietary as-is 3D semantic thermal model of a building and transform it into standard BEM formats. Geometric and relational information regarding the essential structural elements of the building (i.e., zone, ceiling, floor, wall, door, etc.) is, together with their corresponding as-is temperatures, first extracted from thermal points clouds of the scene and then adapted to the standard geometric BEM requirements. Non-geometric properties concerning definitions and properties of envelopes, windows and doors are also defined as essential information. After all this information has been collected, a BEM file is eventually generated in order to be used in energy simulation software. One of the specific features of this work is the generation of as-is BIM formats of the interior of a building that are later adapted for energy simulation applications in EnergyPlus and TRNSYS software. An ASCII file containing the temperatures of the main structural elements of the building is also created. The method has been tested on real thermal point clouds of the ground floor of a building, yielding promising results., This research was funded by the European Regional Development Fund (SBPLY/19/180501/) and the Ministry of Science and In-novation (PID2019-108271RB-C31, PROYECTO/AEI/10.13039/501100011033 and PID2019-108271RB-C33)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

An Environmentally Adaptive CRO-SL Algorithm Based on Dynamic Agents for the Channel Assignment Problem in Wireless Networks

  • Romero-Barrera, Antonio J.
  • de la Cruz-Piris, Luis
  • Marino Tejedor-Romero
  • Ivan Marsa-Maestre
  • Gimenez-Guzman, Jose Manuel|||0000-0002-1645-8476
[EN] In recent decades, metaheuristic algorithms have emerged as indispensable tools for addressing complex optimization challenges, particularly in several engineering fields, where NP-hard problems are prevalent. A common NP-hard problem in communication engineering is the Channel Assignment Problem (CAP) for wireless access points (APs), with a determined number of stations (STAs) connected to them. The performance of the complete network depends on the interference and noise among the different clusters of devices and the obstacles or elements placed in the physical transmission space. To address the CAP, a new environmentally adaptive approach is proposed for the Coral Reefs Optimization with Substrate Layers (CRO-SL) algorithm, introducing new environmental agents: algae (representing tabu positions) and ocean water acidification (lowering fitness thresholds). The Environmentally Adaptive CRO-SL (EnvAdapt-CRO-SL) implementation aims to improve solution exploration, enhancing computational efficacy in generating new candidate solutions within the coral reef population. An exhaustive comparative analysis of four configurations of the proposed EnvAdapt-CRO-SL variant assesses the impact of each environmental agent on the algorithm's performance. Additionally, external benchmarks against four different metaheuristics, along with an analysis of the influence of pseudorandom number generators on initialization and search operators, and a robust optimization case study, provide deeper insights. The results show that incorporating the new environmental agents into the EnvAdapt-CRO-SL workflow significantly boosts throughput while reducing the computational time required to obtain optimal solutions., This work was supported in part by the MCIN/AEI/10.13039/501100011033 and the European Union ''NextGenerationEU''/PRTR under Project TED2021-131387B-I00; in part by the MCIN/ AEI/10.13039/501100011033/FEDER, UE under Project PID2021-123168NB-I00. In addition, this work has been partially funded by the projects SBPLY/23/180225/000160, which is funded by the EU through FEDER and by the JCCM through INNOCAM and WiDAI (CM/JIN/2021-004) of the Community of Madrid and University of Alcala.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Obstructive Sleep Apnea Detection Methods Based on Heart Rate Variability Analysis: Opportunities for a Future Cinc Challenge

  • Padovano, Daniele
  • Martinez-Rodrigo, Arturo
  • Pastor, Jose M.
  • Alcaraz, Raul
  • Rieta, J J|||0000-0002-3364-6380
[EN] The effects of sleep-related disorders, such as obstructive sleep apnea (OSA), can be devastating either in children or adults. Misdiagnosis may lead to severe cardiovascular diseases. Besides, OSA consequences are often related to bad job performance, and road accidents. Nowadays, polysomnography (PSG) is still considered the gold standard for OSA diagnosis, but the required facilities are extremely high, thus reducing availability worldwide. For this reason, simpler and cost-effective diagnosing methods have been proposed in the late years. In this regard, the heart rate variability (HRV) has been demonstrated to strongly reflect apnea episodes during sleep. Hence, this work reviews the latest advances in the evaluation of OSA from the HRV perspective to consider its potentialities for a future revisited CinC Challenge., This research has been supported by grants DPI201783952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-la Mancha and AICO/2019/036 from Generalitat Valenciana. Moreover, Daniele Padovano has held graduate research scholarships from Escuela Polit ' ecnica de Cuenca and Instituto de Tecnolog ' ias Audiovisuales, University of CastillaLa Mancha
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Novel Entropy-Based Metrics for Long-Term Atrial Fibrillation Recurrence Prediction Following Surgical Ablation: Insights from Preoperative Electrocardiographic Analysis

  • Escribano, Pilar
  • Ródenas, Juan
  • García, Manuel
  • Hornero, Fernando
  • Gracia-Baena, Juan M.
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Atrial fibrillation (AF) is a prevalent cardiac arrhythmia often treated concomitantly with other cardiac interventions through the Cox-Maze procedure. This highly invasive intervention is still linked to a long-term recurrence rate of approximately 35% in permanent AF patients. The aim of this study is to preoperatively predict long-term AF recurrence post-surgery through the analysis of atrial activity (AA) organization from non-invasive electrocardiographic (ECG) recordings. A dataset comprising ECGs from 53 patients with permanent AF who had undergone Cox-Maze concomitant surgery was analyzed. The AA was extracted from the lead V1 of these recordings and then characterized using novel predictors, such as the mean and standard deviation of the relative wavelet energy (RWEm and RWEs) across different scales, and an entropy-based metric that computes the stationary wavelet entropy variability (SWEnV). The individual predictors exhibited limited predictive capabilities to anticipate the outcome of the procedure, with the SWEnV yielding a classification accuracy (Acc) of 68.07%. However, the assessment of the RWEs for the seventh scale (RWEs7), which encompassed frequencies associated with the AA, stood out as the most promising individual predictor, with sensitivity (Se) and specificity (Sp) values of 80.83% and 67.09%, respectively, and an Acc of almost 75%. Diverse multivariate decision tree-based models were constructed for prediction, giving priority to simplicity in the interpretation of the forecasting methodology. In fact, the combination of the SWEnV and RWEs7 consistently outperformed the individual predictors and excelled in predicting post-surgery outcomes one year after the Cox-Maze procedure, with Se, Sp, and Acc values of approximately 80%, thus surpassing the results of previous studies based on anatomical predictors associated with atrial function or clinical data. These findings emphasize the crucial role of preoperative patient-specific ECG signal analysis in tailoring post-surgical care, enhancing clinical decision making, and improving long-term clinical outcomes., This research has received financial support from public grants PID2021-123804OB-I00, PID2021- 00X128525-IV0, and TED2021-130935B-I00 of the Spanish Government, 10.13039/501100011033, in conjunction with the European Regional Development Fund (EU), SBPLY/21/180501/000186, from Junta de Comunidades de Castilla-La Mancha, and AICO/2021/286 from Generalitat Valenciana. Pilar Escribano holds the 2020-PREDUCLM-15540 scholarship co-financed by the European Social Fund (ESF) operating program 2014 2020 of Castilla-La Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A Prato Tour on Carbon Nanotubes: Raman Insights

  • Lucío, María Isabel|||0000-0001-7404-352X
  • Giacalone, Francesco
  • La Parola, Valeria
  • Gámez-Valenzuela, Sergio
  • Muñoz-Alba, Fernando
  • Ruiz Delgado, M. Carmen
  • Herrero, M. Antonia
  • Vázquez, Ester
[EN] The functionalisation of carbon nanotubes has been instrumental in broadening its application field, allowing especially its use in biological studies. Although numerous covalent and non-covalent functionalisation methods have been described, the characterisation of the final materials has always been an added challenge. Among the various techniques available, Raman spectroscopy is one of the most widely used to determine the covalent functionalisation of these species. However, Raman spectroscopy is not a quantitative technique, and no studies are reported comparing its performance when the same number of functional groups are added but using completely different reactions. In this work, we have experimentally and theoretically studied the functionalisation of carbon nanotubes using two of the most commonly used reactions: 1,3-dipolar cycloaddition of azomethylene ylides and diazonium-based radical addition. The number of groups introduced onto the tubes by these reactions has been determined by different characterisation techniques. The results of this study support the idea that data obtained by Raman spectra are only helpful for comparing functionalisations produced using the same type of reaction. However, they should be carefully analysed when comparing functionalisations produced using different reaction types., The authors acknowledge financial support from the Spanish government (project PID2020-113080RB-I00) and the Junta de Comunidades de Castilla-La Mancha (project SBPLY/21/180501/000135/1). This study forms part of the Advanced Materials program and was supported by MCIN with funding from European Union NextGenerationEU (PRTR-C17.I1) and by the Junta de Comunidades de Castilla-La Mancha. The work at the University of Malaga was funded by the MICINN (PID202-139548NB-I00) and by the Junta de Andalucia (P18-FR-4559) projects. The authors thankfully acknowledge the computer resources, technical expertise, and assistance provided by the SCBI (Supercomputing and Bioinformatics) centre of the University of Malaga. M. I. L. acknowledges her Juan de la Cierva Incorporacion grant (IJC 2018-035355-I) funded by MCIN/AEI/10.13039/501100011033. Funded with Aid for First Research Projects (PAID-06-22), Vice-rectorate for Research of the Universitat Politecnica de Valencia (UPV).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Modulating charge carrier density and mobility in doped graphene by covalent functionalization

  • Arellano, Luis M.
  • Yue, Sun
  • Gómez-Escalonilla, Maria J.
  • Ortega Higueruelo, Francisco J.
  • Fierro, José Luis G.
  • Langa, Fernando
  • Atienzar Corvillo, Pedro Enrique|||0000-0002-0356-021X
  • García Gómez, Hermenegildo|||0000-0002-9664-493X
[EN] Covalent B-functionalization of B-doped graphene has been performed for the first time. The electronic properties and Hall effect of functionalized N- and B-doped graphene can be tuned by tailoring the electron-donating/-withdrawing properties of the organic addend., The authors appreciate support from the Ministerio de Economia y Competitividad (MINECO) of Spain (projects CTQ2015-69153-CO2-1, CTQ2016-79189-R and MAT2015-69669-P) and the Junta de Comunidades de Castilla-La Mancha (project SBPLY/17/180501/000254). L. M. A. thanks MINECO (CTQ2016-79189-R) for a doctoral FPI grant.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Análisis de la variabilidad temporal de la onda P para predecir el resultado de la ablación por catéter en fibrilación auricular paroxística

  • Ruiz Moreno, A.
  • Arias Palomares, M.A.
  • Puchol Calderón, A.
  • Pachón Iglesias, M.I.
  • Alcaraz Martínez, R.
  • Rieta, J J|||0000-0002-3364-6380
[EN] El aislamiento de las venas pulmonares es el principal tratamiento de la fibrilacion auricular (FA) paroxistica. Sin embargo, presenta una alta tasa de recurrencia y el desarrollo de predictores no invasivos de esta cuestion, es esencial para permitir un tratamiento mas personalizado de cada paciente. Para tal proposito, se han analizado varias caracteristicas de la onda P a partir de registros de electrocardiografia (ECG), pero, aun no se ha estudiado su variabilidad a lo largo del tiempo. Por tanto, este trabajo explora la capacidad de la variabilidad temporal de la duracion y la amplitud de la onda P, para anticipar el fallo de la crioablacion. Paea este estudio antes de la ablacion, se registro un ECG de 5 minutos en 45 pacientes con FA paroxistica. Las ondas P en la derivacion II se delinearon con un algoritmo automatico y se calcularon la duracion y amplitud de todas ellas. A continuacion, se obtuvieron la media, la desviacion estandar y el coeficiente de variacion (CV) para ambos parametros y se correlacionaron con el resultado de la ablacion despues del seguimiento de 9 meses. El CV para ambas caracteristicas de las ondas P presento la capacidad predictiva mas alta de la recurrencia de la FA. Ademas, obtuvo mejoras de alrededor del 10 % en la clasificacion con respecto a la media, alcanzando valores del 70 %. Estos resultados sugieren que la variabilidad temporal de la onda puede proporcionar nueva informacion sobre la heterogeneidad de la conduccion auricular, lo cual podria ser util para mejorar la estrategia de seleccion de candidatos para ser sometidos a crioablacion., Esta investigacion ha sido apoyada por los fondos DPI2017-83952-C3 de MINECO/AEI /FEDER EU,SBPLY/17/180501/000411 de la Junta de Comunidades de Castilla-la Mancha y AICO/2019/036 de la Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Fuzzy and Sample Entropies as Predictors of Patient Survival Using Short Ventricular Fibrillation Recordings during out of Hospital Cardiac Arrest

  • Chicote, Beatriz
  • Irusta, Unai
  • Aramendi, Elisabete
  • Alcaraz, R.
  • Isasi, Iraia
  • Alonso, Daniel
  • Baqueriza, María del Mar
  • Ibarguren, Karlos
  • Rieta, J J|||0000-0002-3364-6380
[EN] Optimal defibrillation timing guided by ventricular fibrillation (VF) waveform analysis would contribute to improved survival of out-of-hospital cardiac arrest (OHCA) patients by minimizing myocardial damage caused by futile defibrillation shocks and minimizing interruptions to cardiopulmonary resuscitation. Recently, fuzzy entropy (FuzzyEn) tailored to jointly measure VF amplitude and regularity has been shown to be an efficient defibrillation success predictor. In this study, 734 shocks from 296 OHCA patients (50 survivors) were analyzed, and the embedding dimension (m) and matching tolerance (r) for FuzzyEn and sample entropy (SampEn) were adjusted to predict defibrillation success and patient survival. Entropies were significantly larger in successful shocks and in survivors, and when compared to the available methods, FuzzyEn presented the best prediction results, marginally outperforming SampEn. The sensitivity and specificity of FuzzyEn were 83.3% and 76.7% when predicting defibrillation success, and 83.7% and 73.5% for patient survival. Sensitivities and specificities were two points above those of the best available methods, and the prediction accuracy was kept even for VF intervals as short as 2s. These results suggest that FuzzyEn and SampEn may be promising tools for optimizing the defibrillation time and predicting patient survival in OHCA patients presenting VF., This work received financial support from Spanish Ministerio de Economia y Competitividad and jointly with the Fondo Europeo de Desarrollo Regional (FEDER), projects TEC2015-64678-R and DPI2017-83952-C3; from UPV/EHU through the grant PIF15/190 and through project GIU17/031; from the Basque Government through grant PRE-2016-1-0012; and from Junta de Comunidades de Castilla-La Mancha through SBPLY/17/180501/000411.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Nozzle rate of injection estimation from hole to hole momentum flux data with different fossil and renewable fuels

  • Payri, Raul|||0000-0001-7428-5510
  • Bracho Leon, Gabriela|||0000-0002-9198-7044
  • Soriano, J. A.
  • Fernández-Yáñez, P.
  • Armas, O.
[EN] Due to environmental problems, research on fuel economy and pollutant emissions in internal combustion engines has drawn the attention of automobile manufacturers and researchers. The diesel engine is one of the most efficient alternatives and one of the main areas of the study in these engines is spray mixing, recognized as a critical factor in combustion control and the reduction of its related contaminants. The studies about fuel sprays rely on experimental data of the rate of injection, which can only be obtained with high-cost equipment. The aim of this paper is to validate for different fuels a method for the determination of the rate of injection based on spray momentum measurements and the total injected mass. After a proper tuning of the test momentum flux device, the injection rate results were validated using the Bosch tube method. The technique was validated for four different fuels, diesel, biodiesel, GTL (Gas-to-liquid) and Farnesane, in order to identify the consequences of the fuel properties on the injection performance characteristics and the estimation method. The results of rate of injection following the procedures presented showed good accuracy when compared to experimental values. These methods can be employed to estimate this parameter when experimental facilities for this purpose are not available., Authors wish to thank the financial support provided by: i) the Spanish Ministry of Science, Innovation and Universities to the project RECUPERA, Ref. Ref.: RTI2018-095923-B-C21 and ii) the government of Castilla-La Mancha community to the project ASUAV, Ref. SBPLY/19/180501/000116. Authors also want to thank: i) the companies REPSOL, SASOL and AMYRIS by the fuels supply, ii) the technical support provided by Nissan Europe Technology Centre Spain.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Distinción Entre Electrogramas de Fibrilación Auricular Paroxística Frente a Persistente para Evaluación del Sustrato Auricular en Procedimientos de Ablación por Catéter

  • Finotti, E.
  • Bertomeu González, V.
  • Hornero Sos, F.
  • Quesada Dorador, A.
  • Alcaraz Martínez, R.
  • Rieta, J J|||0000-0002-3364-6380
[ES] Para contribuir a un abordaje optimizado de la ablacion por cateter (AC) de fibrilacion auricular (FA), durante los ultimos anos se han introducido complicados indices destinados a discriminar FA paroxistica de persistente (FApar vs. FAper) aplicados sobre electrogramas auriculares fraccionados complejos(CFAE). Sin embargo, los electrofisiologos exigen el uso de metodos de clasificacion simples y de comprension directa. Por ello, el presente trabajo explota la longitud de ciclo de FA (AFCL), la frecuencia dominante (DF), la entropia muestral (SE) y el determinismo (DET) del analisis de cuantificacion recurrente, aplicado a registros de FA con CFAEs, para crear modelos sencillos de discriminacion entre FApar y FAper. El AFCL y la DF se calcularon sobre los registros enteros, mientras que SE y DET secalcularon utilizando segmentos de 1, 2 y 4 s. La informacion redundante se elimino umbralizando sucesivamente matrices de correlacion y el algoritmo de Random Forests ordeno las variables por relevancia. A continuacion, un arbol de clasificacion combino de manera optima los indices con alto nivel clasificatorio y se probaron con validacion cruzada dejando uno fuera. Despues de analizar todas las combinaciones posibles, el mejor resultado obtuvo una Precision (Acc) del 88,2 % para discriminar FApar de FAper, mientras que DET proporciono la mejor Acc individual de 82,4 %. Como conclusion, una seleccion cuidada y reducida de caracteristicas puede facilitar un modelo de clasificacion sencillo capaz de discriminar con precision entre CFAEs de FApar y FAper para mejorar el abordaje terapeutico de la FA., El presente trabajo ha sido cofinanciado por los proyectos de investigacion competitiva DPI2017-83952-C3 de MINECO-AEI-FEDER-UE, SBPLY/17/180501/000411 de la JCCLM y AICO/2019/036 de la GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Engineering high levels of saffron apocarotenoids in tomato

  • Ahrazem, Oussama
  • Diretto, Gianfranco
  • Rubio-Moraga, Ángela
  • Lobato-Gómez, María
  • Frusciante, Sarah
  • Argandoña, Javier
  • Gómez-Gómez, Lourdes
  • Rambla Nebot, Jose Luis
  • Presa Castro, Silvia
  • GRANELL RICHART, ANTONIO|||0000-0003-4266-9581
[EN] Crocins and picrocrocin are high-value hydrophilic pigments produced in saffron and used commercially in the food and pharmaceutical industries. These apocarotenoids are derived from the oxidative cleavage of zeaxanthin by specific carotenoid cleavage dioxygenases. The pathway for crocins and picrocrocin biosynthesis was introduced into tomato using fruit specific and constitutive promoters and resulted in 14.48 mg/g of crocins and 2.92 mg/g of picrocrocin in the tomato DW, without compromising plant growth. The strategy involved expression of CsCCD2L to produce crocetin dialdehyde and 2,6,6-trimethyl-4-hydroxy-1-carboxaldehyde-1-cyclohexene, and of glycosyltransferases UGT709G1 and CsUGT2 for picrocrocin and crocins production, respectively. Metabolic analyses of the engineered fruits revealed picrocrocin and crocetin-(beta-D-gentiobiosyl)-(beta-D-glucosyl)-ester, as the predominant crocin molecule, as well as safranal, at the expense of the usual tomato carotenoids. The results showed the highest crocins content ever obtained by metabolic engineering in heterologous systems. In addition, the engineered tomatoes showed higher antioxidant capacity and were able to protect against neurological disorders in a Caenorhabditis elegans model of Alzheimer's disease. Therefore, these new developed tomatoes could be exploited as a new platform to produce economically competitive saffron apocarotenoids with health-promoting properties., This work was supported by grants BIO2016-77000-R from the Spanish Ministerio de Ciencia, Innovacion y Uni-versidades and SBPLY/17/180501/000234 from the Junta de Comunidades de Castilla-La Mancha (co-financed European Union FEDER funds) and HARNESSTOM, contract number 101000716 Innovation Action ECH2020-SFS-2020-1. GD and LGG are participants of the European COST action CA15136 (EUROCAROTEN). GD and AG are participants of the European COST action CA18210 (ROXY). LGG is a participant of the CARNET network (BIO2015-71703-REDT and BIO2017-90877-RED). JLR was supported by the Spanish Ministry of Economy and Competitiveness through a "Juan de la CiervaFormacion" grant (FJCI-2016-28601). The UCLM and the IBMCP researchers constitute the Associated Unit of CAROTENOID BIOTECHNOLOGY.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Detection of Dominant Reentries in Multichannel Electrograms of Atrial Fibrillation

  • Vraka, Aikaterini
  • Osorio, Diego
  • Bertomeu-González, Vicente
  • Ravelli, Flavia
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Algorithms developed so far for the detection of local activation waves (LAWs) in electrograms (EGMs) of atrial fibrillation (AF) analyze each channel of the catheter separately, while dominant reentries of AF are captured by most of the catheter channels simultaneously. This encompasses the risk of losing or oversensing activations in the case of complex fractionated atrial electrograms (CFAEs). The proposed method analyzes multichannel recordings of AF from the least to the most fractionated. Activations are manually annotated and then EGMs are denoised, band-pass filtered by an alternative Bot-teron approach and thresholded. LAW detection is performed sequentially on all the channels by ascending fractionation order. Activations in the first EGM are found by an amplitude-based search, followed by a cycle length (CL) based search. Detection algorithm in the remaining signals is based on the previously detected LAWs, applying a varying search window according to the repetition rate of each activation. A CL-based search is also applied and activation time is computed from the barycenter of each LAW. The final step contains a secondary control that deletes all the low amplitude activations showing low repetition rate, so that any bias regarding the LAW detection of the first EGM is avoided. The method was compared with the equivalent sequential single-channel analysis, with the former showing better accuracy (90.82%) and positive predictive value (96.52%) than the single-channel approach (89.65% and 92.70%, respectively). Multichannel analysis performed a more selective analysis, ignoring some obvious but not repeated LAWs. Consequently, it can localize AF triggers and propagation phenomena more robustly than single channel method., Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2019/036 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electricity consumption analysis for university buildings. Empirical approach for University of Castilla-La Mancha, campus Albacete (Spain).

  • Bastida-Molina, Paula|||0000-0003-3516-0090
  • Torres-Navarro, Juan
  • Honrubia-Escribano, Andrés
  • Gómez-Lázaro, Emilio
[EN] New global situation is boosting the necessity of analysing electricity consumption of university buildings, mainly motived by the exorbitant increase in electricity prices. In this regard, knowing such demand aims at three goals: i) to reduce their consumption, ii) to increase energy efficiency and iii) to develop solar PV installations. Very few research has previously analysed aggregated energy data for educational buildings, and none have studied detailed real electricity consumption in terms of hourly data, which results of utmost relevance, especially for the development of solar PV installations in these environments. Our research tackles this issue and provides a complete methodology to analyse electrical energy and hourly data consumption in university buildings, based on electricity indicators and patterns. The research has been applied to the University of Castilla-La Mancha, in Spain. A complete year data base (2021) of real power and electrical energy consumption of the whole campus has been collected and analysed, with an hourly scale. Results revealed that Biomedical Complex corresponds to the highest load demanding building of the campus (2770 MWh, 43% of the total campus). Outcomes also disclosed an annual high consumption base of 250 kWh for this building, together with 6 different seasonality patterns and 2 annual daily patterns., This work was supported in part by the Spanish Public Administration "Ministerio de Universidades" under the grant Margarita Salas-Universitat Politècnica de València, funded by the European Union-Next Generation EU, by the Council of Communities of Castilla-La Mancha (Junta de Comunidades de Castilla-La Mancha, JCCM) through project SBPLY/19/180501/000287 and by the European Regional Development Fund (Fondo Europeo de Desarrollo Regional, FEDER).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The Relevance of Heart Rate Fluctuation When Evaluating Atrial Substrate Electrical Features in Catheter Ablation of Paroxysmal Atrial Fibrillation

  • Vraka, Aikaterini
  • Moreno-Arribas, José
  • Gracia-Baena, Juan M.
  • Hornero, Fernando
  • Alcaraz, Raúl
  • Rieta, J J
[EN] Coronary sinus (CS) catheterization is critical during catheter ablation (CA) of atrial fibrillation (AF). However, the association of CS electrical activity with atrial substrate modification has been barely investigated and mostly limited to analyses during AF. In sinus rhythm (SR), atrial substrate modification is principally assessed at a global level through P-wave analysis. Cross-correlating CS electrograms (EGMs) and P-waves' features could potentiate the understanding of AF mechanisms. Five-minute surface lead II and bipolar CS recordings before, during, and after CA were acquired from 40 paroxysmal AF patients. Features related to duration, amplitude, and heart-rate variability of atrial activations were evaluated. Heart-rate adjustment (HRA) was applied. Correlations between each P-wave and CS local activation wave (LAW) feature were computed with cross-quadratic sample entropy (CQSE), Pearson correlation (PC), and linear regression (LR) with 10-fold cross-validation. The effect of CA between different ablation steps was compared with PC. Linear correlations: poor to mediocre before HRA for analysis at each P-wave/LAW (PC: max. +18.36%, p = 0.0017, LR: max. +5.33%, p = 0.0002) and comparison between two ablation steps (max. +54.07%, p = 0.0205). HRA significantly enhanced these relationships, especially in duration (P-wave/LAW: +43.82% to +69.91%, p < 0.0001 for PC and +18.97% to +47.25%, p < 0.0001 for LR, CA effect: +53.90% to +85.72%, p < 0.0210). CQSE reported negligent correlations (0.6-1.2). Direct analysis of CS features is unreliable to evaluate atrial substrate modification due to CA. HRA substantially solves this problem, potentiating correlation with P-wave features. Hence, its application is highly recommended., This research received partial financial support from public grants DPI2017-83952-C3, PID2021-00X128525-IV0, PID2021-123804OB-I00. and TED2021-129996B-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund (EU), SB-PLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha. and AICO/2021/286 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

A Deep Learning Solution for Automatized Interpretation of 12-Lead ECGs

  • Huerta, Alvaro
  • Martinez-Rodrigo, Arturo
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] A broad variety of algorithms for detection and classification of rhythm and morphology abnormalities in ECG recordings have been proposed in the last years. Although some of them have reported very promising results, they have been mostly validated on short and non-public datasets, thus making their comparison extremely difficult. PhysioNet/CinC Challenge 2020 provides an interesting opportunity to compare these and other algorithms on a wide set of ECG recordings. The present model was created by ¿ELBIT¿ team. The algorithm is based on deep learning, and the segmentation of all beats in the 12-lead ECG recording, generating a new signal for each one by concatenating sequentially the information found in each lead. The resulting signal is then transformed into a 2- D image through a continuous Wavelet transform and inputted to a convolutional neural network. According to the competition guidelines, classification results were evaluated in terms of a class-weighted F-score (Fß) and a generalization of the Jaccard measure (Gß). In average for all training signals, these metrics were 0.933 and 0.811, respectively. Regarding validation on the testing set from the first phase of the challenge, mean values for both performance indices were 0.654 and 0.372, respectively, This research has been supported by the grants DPI2017¿83952¿C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha, AICO/2019/036 from Generalitat Valenciana and FEDER 2018/11744
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Time Variability of P-wave Features from the Preoperative Electrocardiogram Predicts Recurrence After Catheter Cryoablation of Atrial Fibrillation

  • Ruiz, Antonio
  • Arias, Miguel A.
  • Puchol, Alberto
  • Pachón, Marta I.
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Pulmonary vein isolation is nowadays the cornerstone for the treatment of paroxysmal atrial fibrillation (AF). However, its success rate is not as high as clinically desirable, and repeated procedures are often required. In this context, the development of noninvasive, pre-ablation predictors of the procedure failure is essential to enable tailored approaches. For that purpose several P-wave features have been analyzed from short electrocardiogram (ECG) recordings, but their time variability has not been studied yet. Hence, this work explores the ability of time variability of two common P-wave parameters, such as duration and amplitude, to anticipate cryoablation failure. Before ablation, a standard 12-lead ECG was recorded continuously for 5 minutes from 45 paroxysmal AF patients. All P-waves in lead II were delineated with an automatic algorithm. Duration and amplitude of all waves were computed, and then mean, standard deviation (std), and coefficient of variation (CV) were obtained for both parameters and correlated with ablation outcome after a follow-up of 9 months. The CV for both P-waves features reported the best separation between the patients who maintained sinus rhythm and those who relapsed to AF. Moreover, improvements about 10% in diagnostic ability were obtained by the CV with regards to the mean, reaching values about 70%. These results suggest that time variability of the P-wave can provide new insights about atrial conduction heterogeneity, which could be helpful in improving the selection strategy of optimal candidates for cryoablation., This research has been supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-la Mancha and AICO/2019/036 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Catheter Ablation Outcome Prediction With Advanced Time-Frequency Features of the Fibrillatory Waves From Patients in Persistent Atrial Fibrillation

  • Escribano, Pilar
  • Ródenas, Juan
  • Arias, Miguel A.
  • Langley, Philip
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Although catheter ablation (CA) is still the first-line treatment for persistent atrial fibrillation (AF) patients, its limited long-term success rate has motivated clinical interest in preoperative prediction on the procedure¿s outcome to provide optimized patient selection, limit repeated procedures, hospitalization rates, and treatment costs. To this respect, dominant frequency (DF) and amplitude of fibrillatory waves (f-waves) reflected on the ECG have provided promising results. Hence this work explores the ability of a novel set of frequency and amplitud f-waves features, such as spectral entropy (SE), spectral flatness measure (SFM), and amplitud spectrum area (AMSA), along with DF and normalized f-wave amplitude (NFWA), to improve CA outcome prediction. Despite all single indices reported statistically significant differences between patients who relapsed to AF and those who maintained sinus rhythm after a follow-up of 9 months for 204 6 s-length ECG intervals extracted from 51 persistent AF patients, they obtained a limited discriminant ability ranging between 55 and 62%, which was overcome by 15¿23% when NFWA, SE and AMSA were combined. Consequently, this combination of frequency and amplitude features of the fwaves seems to provide new insights about the atrial substrate remodeling, which could be helpful in improving preoperative CA outcome prediction., This research has been supported by grants DPI201783952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-la Mancha and AICO/2019/036 from Generalitat Valenciana. Moreover, Pilar Escribano holds a graduate research scholarship from University of Castilla-La Mancha
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Unsupervised Learning for Lateral-Movement-Based Threat Mitigation in Active Directory Attack Graphs

  • Herranz-Oliveros, David
  • Tejedor-Romero, Marino
  • de la Cruz-Piris, Luis
  • Gimenez-Guzman, Jose Manuel|||0000-0002-1645-8476
[EN] Cybersecurity threats, particularly those involving lateral movement within networks, pose significant risks to critical infrastructures such as Microsoft Active Directory. This study addresses the need for effective defense mechanisms that minimize network disruption while preventing attackers from reaching key assets. Modeling Active Directory networks as a graph in which the nodes represent the network components and the edges represent the logical interactions between them, we use centrality metrics to derive the impact of hardening nodes in terms of constraining the progression of attacks. We propose using Unsupervised Learning techniques, specifically density-based clustering algorithms, to identify those nodes given the information provided by their metrics. Our approach includes simulating attack paths using a snowball model, enabling us to analytically evaluate the impact of hardening on delaying Domain Administration compromise. We tested our methodology on both real and synthetic Active Directory graphs, demonstrating that it can significantly slow down the propagation of threats from reaching the Domain Administration across the studied scenarios. Additionally, we explore the potential of these techniques to enable flexible selection of the number of nodes to secure. Our findings suggest that the proposed methods significantly enhance the resilience of Active Directory environments against targeted cyber-attacks., This publication is part of project TED2021-131387B-I00 funded by MCIN/AEI/10.13039/501100011033 and by the European Union "NextGenerationEU"/PRTR and of project PID2021-123168NB-I00 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE. Finally, this work is a part of the research project SBPLY/23/180225/000160, which is funded by the EU through FEDER, Spain, and by the JCCM through INNOCAM. David Herranz is also funded by both an FPU grant and a Mobility Grant for Research Staff in Training from the University of Alcala.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Democratic Wireless Channel Assignment: Fair Resource Allocation in Wi-Fi Networks

  • Marsa-Maestre, Ivan
  • Tejedor-Romero, Marino
  • de la Hoz, Enrique
  • Murukannaiah, Pradeep
  • Gimenez-Guzman, Jose Manuel|||0000-0002-1645-8476
This work was supported in part by Project PID2019-104855RB-I00/AEI/10.13039/501100011033 of the Spanish Ministry of Science and Innovation, in part by Project SBPLY/19/180501/000171 of the Junta de Comunidades de Castilla-La Mancha and FEDER, and in part by Projects UCeNet (CM/JIN/2019-031) and WiDAI (CM/JIN/2021-004) of the Comunidad de Madrid and University of Alcala. The work of M. Tejedor Romero was supported by a Ph.D. Grant from the Universidad de Alcala. The authors also would like to thank Prof. R. Aydogan for her insightful comments about the manuscript.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

An Experimental Review on Obstructive Sleep Apnea Detection Based on Heart Rate Variability and Machine Learning Techniques

  • Padovano, Daniele
  • Martinez-Rodrigo, Arturo
  • Pastor, Jose M.
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Obstructive sleep apnea (OSA) is a respiratory syndrome of high incidence in the general population and correlated with some cardiovascular diseases. Several techniques have been proposed in the last decades to find a surrogate method to polysomnography (PSG), the gold standard for the diagnosis of OSA. The present study comprises an experimental review on the state-of-the-art methods for OSA detection through the public Apnea-ECG database, which is available at PhysioNet. Precisely, traditional time-frequency domain features were extracted from the heart rate variability (HRV) signal, together with some common complexity measures. Given their ability to deal with real-world time series, two additional entropy-based measures were also tested, i.e., Rènyi and Tsallis entropies. Moreover, univariate and multivariate classifiers were applied, including diagnostic test, support vectors machine, and k-nearest neighbors. Ultimately, two sequential feature selection (SFS) algorithms were employed to reduce the computational cost of the resulting discriminant models. The major findings reported that multivariate classifiers reached similar results to those found in the literature. Moreover, univariate classification results suggested that the frequency domain features provided the best OSA detection, although a well-known entropy index also obtained a good performance., This research has been supported by grants DPI2017-83952- C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/ 000411 from Junta de Comunidades de Castilla-la Mancha and AICO/2019/036 from Generalitat Valenciana. Moreover, Daniele Padovano has held graduate research scholarships from Escuela Politecnica de Cuenca and Instituto de Tecnolog ¿ ¿¿as Audiovisuales, University of Castilla-La Mancha
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The Dissimilar Impact in Atrial Substrate Modification of Left and Right Pulmonary Veins Isolation after Catheter Ablation of Paroxysmal Atrial Fibrillation

  • Vraka, Aikaterini
  • Bertomeu-González, Vicente
  • Fácila, Lorenzo
  • Moreno-Arribas, José
  • Alcaraz, Raul
  • Rieta, J J|||0000-0002-3364-6380
[EN] Since the discovery of pulmonary veins (PVs) as foci of atrial fibrillation (AF), the commonest cardiac arrhythmia, investigation revolves around PVs catheter ablation (CA) results. Notwith-standing, CA process itself is rather neglected. We aim to decompose crucial CA steps: coronary sinus (CS) catheterization and the impact of left and right PVs isolation (LPVI, RPVI), separately. We recruited 40 paroxysmal AF patients undergoing first-time CA and obtained five-minute lead II and bipolar CS recordings during sinus rhythm (SR) before CA (B), after LPVI (L) and after RPVI (R). Among others, duration, amplitude and atrial-rate variability (ARV) were calculated for P-waves and CS local activation waves (LAWs). LAWs features were compared among CS channels for reliability analysis. P-waves and LAWs features were compared after each ablation step (B, L, R). CS channels: amplitude and area were different between distal/medial (p <= 0.0014) and distal/mid-proximal channels (p <= 0.0025). Medial and distal showed the most and least coherent values, respectively. Correlation was higher in proximal (>= 93%) than distal (<= 91%) areas. P-waves: duration was significantly shortened after LPVI (after L: p = 0.0012, -13.30%). LAWs: insignificant variations. ARV modification was more prominent in LAWs (L: >+73.12%, p <= 0.0480, R: <-33.94%, p <= 0.0642). Medial/mid-proximal channels are recommended during SR. CS LAWs are not significantly affected by CA but they describe more precisely CA-induced ARV modifications. LPVI provokes the highest impact in paroxysmal AF CA, significantly modifying P-wave duration., This research has received partial financial support from public grants DPI2017-83952-C3, PID2021-00X128525-IV0, PID2021-123804OB-I00 and TED2021-129996B-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund (EU), SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha and AICO/2021/286 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Effects of Long-Term Cryopreservation on Sperm Quality and Oxidative Stress in Manchega Rams (Ovis aries)

  • Soria-Meneses, Pedro Javier
  • Jurado-Campos, Alejandro
  • Rubio de Juan, Alejandro
  • Montoro Angulo, Vidal
  • Soler, Ana Josefa
  • Garde, José Julián
  • Ramón Fernández, Manuel
  • Fernandez-Santos, María del Rocío
[EN] Cryopreservation plays an essential role in artificial insemination protocols and in the establishment of germplasm banks. However, cryopreservation is a key factor contributing to the increase in oxidative stress, potentially leading to deterioration of sperm quality over time. This study examined whether oxidative stress levels differed in Manchega sheep sperm samples stored for up to 25 years. It was hypothesised that these differences could be due to storage time or genetic selection focused on productive traits, given the antagonism between productive and reproductive traits. Frozen sperm samples from 145 rams, all cryopreserved at the same age and processed under identical conditions to minimise variation, were analysed. Sperm viability, intracellular reactive oxygen species production, lipid peroxidation, and chromatin integrity were assessed. The impact of cryopreservation storage duration on sperm quality was evaluated, and genetic trends were estimated using pedigree and genomic data to explore potential associations with reproductive genes. Our results revealed minimal changes in sperm quality parameters across generations. A negative trend was observed in oxidative stress indicators, while sperm viability exhibited a slight positive trend, suggesting that oxidative stress may have a greater impact on older frozen samples. Genetic trend analysis revealed no significant differences, and no associations with reproductive genes were found, which indicates that the deterioration in sperm quality was primarily due to storage time rather than genetic selection. However, sperm quality is influenced by multiple genes not examined in this study, and a genetic effect cannot be completely discarded., Financial support for this work was from grants SBPLY/21/180501/000111 and SBPLY/17/180501/000369 funded by the Education and Science Council of Junta de Comunidades de Castilla-La Mancha, and grants GL2017-85603-P, PID2020-120281RB-100, and PID2020-117788RB-100 funded by MICIU/AEI/10.13039/501100011033 (Spanish Ministry of Science, Innovation and Universities) and the European Union. PJS-M was supported by a JCCM scholarship, and AJ-C was supported by a UCLM scholarship.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Novel Photoplethysmographic and Electrocardiographic Features for Enhanced Detection of Hypertensive Individuals

  • Cano, Jesús
  • Quesada, Aurelio
  • Ravelli, Flavia
  • Zangróniz, Roberto
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Hypertension is a major risk factor for many cardiovascular diseases, which are the leading cause of death worldwide. Regular monitoring is essential to provide early diagnosis since most patients with elevated blood pressure (BP) have asymptomatic hypertension. This work presents a method for BP classification using simultaneous electrocardiographic (ECG), photoplethysmographic (PPG) and BP signals. 86 recordings were used, being 35 normotensive, 26 prehypertensive and 25 hypertensive. It has been proposed 23 novel features to improve the discrimination between healthy and hypertensive individuals based on pulse arrival times (PAT) and morphological features from PPG, VPG and APG signal. Moreover, alternative classification models as Support Vector Machines (SVM), Naive Bayes or Coarse Trees were trained with the defined features to compare the classification performance. The classifier that provided the highest results comparing normotensive with prehypertensive and hypertensive subjects were Coarse Tree, providing an F1 score of 85.44% (Se of 86.27% and Sp of 77.14%). The use of new PPG and ECG features has successfully improved the discrimination between healthy and hypertensive individuals, around 7% of F1 score, so this machine learning methodology would be of high interest to detect HT introducing these techniques in wearable devices., Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2021/286 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A model-driven approach to adopt good practices for agile process configuration and certification

  • Giachetti-Herrera, Giovanni Andrés
  • Marín, Beatriz|||0000-0001-8025-0023
  • de la Vara, José Luis
[EN] Context: The agile development paradigm has been extensively adopted in the industry. This adoption is highly dependent on the knowledge and good practices applied by most experienced practitioners in organizations. Hence, it would be valuable to count on appropriate support to preserve and systematically use this expert knowledge in configuring agile development processes aligned with organizational standards. Objective: This paper presents a model-driven approach for representing and selecting good practices to configure agile practices in development processes aligned with organizational development practices and quality standards. Method: We define a conceptual approach for configuring agile development processes that fulfills enterprise good practices and external quality standards. This approach was implemented in a tool suite and applied to an industrial development scenario related to ISO 9001 certification. Results: The approach was implemented in a model-driven tool that provides automatic support for identifying good practices when configuring agile development processes. The tool also verifies consistency with development methods and quality standards, such as ISO 9001. Conclusions: The results obtained from the industrial application indicate that practitioners can reuse expert knowledge to configure agile development processes aligned with quality certifications. Moreover, the approach also facilitates the tailoring of agile practices into concrete development processes that take advantage of organizational good practices., The work leading to this paper received funding from the iRel4.0 (H2020-ECSEL grant agreement no 876659; Spain's MICINN ref. PCI2020-112240), VALU3S (H2020-ECSEL grant agreement no 876852; Spain's MICINN ref. PCI2020-112001); Treasure (JCCM ref. SBPLY/19/180501/000270; EC's European Regional Development Fund) projects; The Ramon y Cajal Program (Spain's MICINN ref. RYC-2017-22836; EC's European Social Fund); ENACTEST project (ERASMUS+ Project Number 101055874-ENACTEST-ERASMUS-EDU-2021-PI-ALL-INNO); The Valencian Innovation Agency and Innovation through the OGMIOS project (INNEST/2021/57); The Generalitat Valenciana through the CoMoDiD project (CIPROM/2021/023); The Spanish State Research Agency through the DELFOS (PDC2021-121243-I00) and SREC (PID2021-123824OB-I00) projects; MICIN/AEI/10.13039/501 100011033; and co-financed with ERDF and the European Union Next Generation EU/PRTR; SIAM (Chile's CORFO-INNOVA ref. 16COTE-60218), and from NISUM Technologies Chile.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A Novel Nonlinear Method for Cardiovascular Data Synchronization

  • Padovano, Daniele
  • Martinez-Rodrigo, Arturo
  • Marwan, Norbert
  • Mula Muñoz, Santiago
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] This study introduces and evaluates a novel nonlinear technique for synchronizing electrocardiogram (ECG) and photoplethysmogram (PPG) signals by embracing the intrinsic relationship between heart rate variability (HRV) and pulse rate variability (PRV). The proposed method utilizes normalized mutual information (NMI) derived from cross-distance matrices (CDM) of HRV and PRV, alongside the distance matrix of a reference HRV extract. We tested the methodology on two databases containing simultaneous ECG and PPG signals, including one publicly available on Physionet, and benchmarked it against various synchronization techniques, both linear (Pearson coefficient, dynamic time warping) and nonlinear (conventional mutual information, NMI with recurrence plots, cross-recurrence plot, and determinism). Results showed that the proposed method (NMI of CDM) outperformed all others, achieving synchronization rates near 50% within a 1.2-second lag threshold. This study also comprehensively examines how signal quality and recording methodology variations affect synchronization outcomes, confirming the importance of lag threshold adjustment for real accuracy assessment. However, some limitations must be kept in mind: the proposed approach is not suited for blood pressure estimation based on HRV-PRV differences, nonlinear methods generally require higher computational resources than linear ones, and further validation is needed with additional databases from real-world scenarios similar to those used in this study., This work was supported in part by MICIU/AEI/10.13039/501100011033, Fondo Europeo de Desarrollo Regional (FEDER) European Union (EU), and NextGenerationEU/Plan de Recuperacion, Transformacion y Resiliencia (PRTR) under Grant PID2021-128525OB-I00, Grant PID2021-123804OB-I00, and Grant TED2021-130935B-I00; in part by European Regional Development Fund (EU) from Junta de Comunidades de Castilla-La Mancha under Grant SBPLY/21/180501/000186 and Grant SBPLY/21/180225/000080; and in part by the Generalitat Valenciana under Grant AICO/2021/286. The work of Daniele Padovano was supported by the Predoctoral Scholarship, which is co-financed by the Operating Program of European Social Fund (ESF) (2014-2020) of Castilla-La Mancha under Grant 2022-PRED-20642.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Fighting Child Poverty in Spain by Moving Towards European Standards: A Microsimulation-Based Case Study

  • Ayala, Luis
  • Cantó, Olga
  • Romaguera-de-la-Cruz, Marina
  • Petrov, Dmitry
[EN] Poverty in Spain is widespread among children, and its incidence has recently shown a strong upward trend. The aim of this paper is twofold: to assess the impact of the Spanish tax and benefit system on current child poverty rates and, in that context, to simulate the potential distributive consequences of implementing a variety of family transfer schemes using an EU-wide static microsimulation tool (EUROMOD). We simulate and study the effects of choosing different policies: a redesign of the current means-tested child benefit in terms of amount and age distribution, a reform of the existing income tax relief making it refundable and the addition of a taxable Universal Child Benefit (UCB) to the system. Our results indicate that several of the proposed reforms could generate substantial reductions in child poverty., Olga Cantó, Marina Romaguera-de-la-Cruz and Dmitry Petrov acknowledge financial support from Junta de Comunidades de Castilla-La Mancha Grant SBPLY/24/180225/000210 and from the Ministerio de Ciencia e Innovación Grant PID2022-137352NB-C42 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Euro
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Channel Selection in Uncoordinated IEEE 802.11 Networks Using Graph Coloring

  • Gimenez-Guzman, Jose Manuel|||0000-0002-1645-8476
  • Marsá-Maestre, Iván
  • de la Hoz, Enrique
  • Orden, David
  • Herranz-Oliveros, David
[EN] One of the big challenges in decentralized Wi-Fi networks is how to select channels for the different access points (APs) and their associated stations (STAs) in order to minimize interference and hence maximize throughput. Interestingly enough, de facto standards in terms of uncoordinated channel selection are quite simple, and in many cases result in fairly suboptimal channel allocations. Here, we explore how graph coloring can be used to evaluate and inform decisions on Wi-Fi channel selection in uncoordinated settings. Graph coloring, in its most basic form, is a classic mathematical problem where colors have to be assigned to nodes in a graph while avoiding assigning the same color to adjacent nodes. In this paper, we modeled Wi-Fi uncoordinated channel selection as a graph coloring problem and evaluated the performance of different uncoordinated channel selection techniques in a set of representative scenarios of residential buildings. The results confirm some of the widely accepted consensus regarding uncoordinated channel selection but also provide some new insights. For instance, in some settings, it would be better to delegate the decision on which channel to use to transmit the STAs, rather than having the AP make the decision on its own, which is the usual way., This publication is part of Project TED2021-131387B-I00 funded by MCIN/AEI/10.13039/501100011033 and by the European Union "NextGenerationEU"/PRTR and of Project PID2021-123168NB-I00 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE. Ivan Marsa-Maestre and David Orden are partially funded by Project SB-PLY/19/180501/000171 of the Junta de Comunidades de Castilla-La Mancha and FEDER and by Project WiDAI (CM/JIN/2021-004) of the Comunidad de Madrid and University of Alcala. Jose Manuel Gimenez-Guzman, Ivan Marsa-Maestre, and David Herranz-Oliveros are also funded by Project PID2019-104855RB-I00/AEI/10.13039/501100011033 of the Spanish Ministry of Science and Innovation. David Orden is also partially supported by Project PID2019-104129GB-I00/AEI/10.13039/501100011033 of the Spanish Ministry of Science and Innovation. The APC was funded by Project TED2021-131387B-I00 funded by MCIN/AEI/10.13039/501100011033 and by the European Union "NextGenerationEU"/PRTR.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Improved Discrimination Between Healthy and Hypertensive Individuals Combining Photoplethysmography and Electrocardiography

  • Cano, Jesús
  • Hornero, Fernando
  • Quesada, Aurelio
  • Martínez-Rodrigo, Arturo
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Cardiovascular disease is one of the leading causes of death, with hypertension (HT) being its main risk factor. Its complications can be avoided with early treatment, but since these patients do not present any symptoms, HT is often detected at very advanced stages. This work presents a model for estimating blood pressure (BP) from electrocardiographic (ECG) and photoplethysmographic (PPG) signals, which can be easily obtained by means of wearable continuous monitoring devices. ECG, PPG and BP recordings from 86 patients were analyzed.A total of 34 standard and new features based on previous works were defined, such as pulse arrival times (PAT), and morphological characteristics of PPG signal. 37 classification models, ranging from Logistic Regression, Support Vector Machines (SVM), Nearest Neighbors, Naive Bayes or Coarse Trees were trained to compare discrimination results. The classifier that provided the highest performance when comparing normotensive patients with prehypertensive and hypertensive patients were Coarse Tree, providing an F1 score of 85.44% (Se of 86.27% and Sp of 77.14%). The use of PPG and ECG features has successfully discriminated between healthy and hypertensive individuals and, thus, could be used to detect HT by embedding these techniques in wearable devices., Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2021/286 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Predicción del fracaso temprano de la cardioversión eléctrica en fibrilación auricular sobre las 12 derivaciones del ECG estándar

  • Cirugeda Roldan, E.M.
  • Calero Núñez, S.
  • Quesada Dorador, A.
  • Hidalgo Olivares, V.M.
  • Alcaraz Martínez, R.
  • Rieta, J J|||0000-0002-3364-6380
[ES] Dentro de las tecnicas existentes para el control del ritmo cardiaco en fibrilacion auricular (FA), una de las mas extendidas es la cardioversion electrica (CVE). Esta tecnica, de aplicacion sencilla y bajo coste, resulta muy efectiva en la restauracion del ritmo sinusal (RS) en pacientes con FA persistente. Aunque es capaz de restaurar el RS en la gran mayoria, un alto numero de pacientes, alrededor del 40 %, todavia revierten a FA durante las 4 primeras semanas. Asi pues, resulta de gran interes clinico la prediccion del exito de la CVE para poder tratar de la mejor forma a cada paciente. Con dicho objetivo, se han propuesto distintos indices para caracterizar las ondas fibrilatorias (f), generalmente considerando solo la derivacion V1 del ECG, dada su proximidad a la auricula derecha, y asi descartando otra informacion relevante que pudiera obtenerse desde otras derivaciones. Este trabajo extiende dicha caracterizacion de las ondas f a las 12 derivaciones del ECG estandar para evaluar la capacidad de prediccion del fracaso temprano de la CVE. Se han evaluado tres de los indices mas conocidos, es decir, la amplitud de las ondas f, la frecuencia dominante y la regularidad, y su rendimiento se ha comparado con el obtenido sobre V1. Los resultados obtenidos indican que, mediante la caracterizacion de las ondas f sobre la derivacion II, la prediccion del resultado de la CVE aumenta hasta un 12 % con respecto a V1, sugiriendo que esta derivacion es la mejor eleccion para evaluar la condicion proarritmica de un paciente tras la CVE., Este trabajo ha sido cofinanciado por los proyectos de investigacion competitiva DPI2017-83952-C3 de MINECO-AEI-FEDER-UE, SBPLY/17/180501/000411 de la JCCLM y AICO/2019/036 de la GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Fuel savings on missed approach through aircraft reinjection

  • Carmona, María
  • Casado González, Rafael
  • Bermúdez, Aurelio
  • Pérez-Francisco, Miguel
  • Boronat-Perez, Pablo
  • Tavares De Araujo Cesariny Calafate, Carlos Miguel|||0000-0001-5729-3041
[EN] PurposeIn the aerial transportation area, fuel costs are critical to the economic viability of companies, and so urgent measures should be adopted to avoid any unnecessary increase in operational costs. In particular, this paper addresses the case of missed approach manouevres, showing that it is still possible to optimize the usual procedure.Design/methodology/approachThe costs involved in a standard procedure following a missed approach are analysed through a simulation model, and they are compared with the improvements achieved with a fast reinjection scheme proposed in a prior work.FindingsExperimental results show that, for a standard A320 aircraft, fuel savings ranging from 55% to 90% can be achieved through the reinjection method.Originality/valueTo the best of the authors' knowledge, this work is the first study in the literature addressing the fuel savings benefits obtained by applying a reinjection technique for missed approach manoeuvres., This work is derived from R&D projects RTI2018-098156-B-C52 and RTI2018-096384-B-I00, funded by MCIN/AEI/10.13039/501100011033 and "ERDF A way of making Europe", by the Junta de Comunidades de Castilla-La Mancha under grant SBPLY/19/180501/000159, and by the Universidad de Castilla-La Mancha under grant 2021-GRIN-31042.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The Relevance of Calibration in Machine Learning-Based Hypertension Risk Assessment Combining Photoplethysmography and Electrocardiography

  • Cano, Jesús
  • Fácila, Lorenzo
  • Gracia-Baena, Juan M.
  • Zangróniz, Roberto
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] The detection of hypertension (HT) is of great importance for the early diagnosis of cardiovascular diseases (CVDs), as subjects with high blood pressure (BP) are asymptomatic until advanced stages of the disease. The present study proposes a classification model to discriminate between normotensive (NTS) and hypertensive (HTS) subjects employing electrocardiographic (ECG) and photoplethysmographic (PPG) recordings as an alternative to traditional cuff-based methods. A total of 913 ECG, PPG and BP recordings from 69 subjects were analyzed. Then, signal preprocessing, fiducial points extraction and feature selection were performed, providing 17 discriminatory features, such as pulse arrival and transit times, that fed machine-learning-based classifiers. The main innovation proposed in this research uncovers the relevance of previous calibration to obtain accurate HT risk assessment. This aspect has been assessed using both close and distant time test measurements with respect to calibration. The k-nearest neighbors-classifier provided the best outcomes with an accuracy for new subjects before calibration of 51.48%. The inclusion of just one calibration measurement into the model improved classification accuracy by 30%, reaching gradually more than 96% with more than six calibration measurements. Accuracy decreased with distance to calibration, but remained outstanding even days after calibration. Thus, the use of PPG and ECG recordings combined with previous subject calibration can significantly improve discrimination between NTS and HTS individuals. This strategy could be implemented in wearable devices for HT risk assessment as well as to prevent CVDs., This research received financial support from grants PID2021-00X128525-IV0, PID2021123804OB-I00 and TED2021-129996B-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund (EU), SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha and AICO/2021/286 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

An experimental methodology for the calibration of indoor building environment models using thermal point clouds and CFD simulation

  • Ramón-Constantí, Amanda|||0000-0001-7084-8275
  • Adan-Oliver, Antonio
  • Castilla-Pascual, Francisco Javier
  • Pérez-Andreu, Víctor
[EN] This paper presents an experimental methodology employing thermal point clouds (TPCs) of indoor spaces to develop and calibrate Computational Fluid Dynamics (CFD) models for simulating indoor building environments. TPCs, captured at various time intervals, provide geometry and surface temperatures of the space envelope are crucial for initial and final contrast parameters in model calibration. Segments from TPCs of interior surfaces serve as ground truth for calibrating theoretical CFD models. This involves adjusting boundary conditions to approximate real surface temperature distributions on selected walls. The innovative calibration approach incorporates automatic wall segmentation processes, enabling comparison between in-situ measured and simulated values. A case study assesses the similarity between real thermal orthoimages and CFD simulations, employing qualitative and quantitative analysis with a convergence criterion. Results validate the methodology, highlighting the need for further automation of manual processes., This work was supported by the European Regional Development Fund (project SBPLY23180225000113) and the Spanish Ministry of Science, Innovation and Universities (project PID2022-141275OB-C21/AEI/10.13039/501100011033/ FEDER, UE).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Predicción del Éxito de la Ablación por Catéter en Fibrilación Auricular Persistente Mediante Características Tiempo-Frecuencia de las Ondas Fibrilatorias

  • Escribano Cano, P.
  • Ródenas García, J.
  • Arias Palomares, M.A.
  • Langley, P.
  • Alcaraz Martínez, R.
  • Rieta, J J|||0000-0002-3364-6380
[ES] A pesar de su limitada tasa de éxito a largo plazo, la ablación por catéter (AC) es el tratamiento de primera línea de la fibrilación auricular (FA) persistente. La predicción preoperatoria del resultado de este procedimiento permitiría optimizar la selección de pacientes, entre otras ventajas clínicas y económicas. Con este fin, la frecuencia dominante (FD) y la amplitud de las ondas fibrilatorias (ondas f) normalizada (AOFn) reflejadas en el registro electrocardiográfico (ECG) ya han proporcionado resultados prometedores, pero insuficientes desde un punto de vista clínico. Este trabajo explora la capacidad de un conjunto de características frecuenciales y de amplitud de las ondas f para mejorar la predicción del resultado de la AC. Asi pues, además de los dos índices anteriormente indicados, se han analizado: la entropía espectral (EE), la medida de la planicidad espectral (MPE) y la suma ponderada de la amplitud espectral (SPAE). Los resultados obtenidos para 204 intervalos de ECG, extraídos de 51 pacientes con FA persistente, muestran para todos los índices diferencias estadísticamente significativas entre los pacientes que mantuvieron ritmo sinusal (RS) y los que recayeron a FA tras un seguimiento de 9 meses, pero una capacidad discriminante limitada, entre un 55 y un 62 %. Este resultado se mejoro en un 15-23 % cuando se combinaron mediante un análisis lineal discriminante AOFn, EE y SPAE, obteniendo un valor del 77,2 %. En consecuencia, esta combinación de características de frecuencia y amplitud parece proporcionar nueva información sobre el remodelado del sustrato auricular, la cual podría ser útil para mejorar la predicción del resultado de la AC., Trabajo financiado por los proyectos DPI2017-83952-C3 MINECO/AEI/FEDER, EU, SBPLY/17/180501000411 de la Junta de Comunidades de Castilla-La Mancha y AICO/2019/036 de la Generalitat Valenciana. Ademas, Pilar Escribano Cano tiene una beca de investigacion de posgrado y un posterior contrato predoctoral 2020-PREDUCLM15540, ambos por la Universidad de Castilla-La Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Discriminación Mejorada Entre Personas Sanas e Hipertensas Combinando Fotopletismografía y Electrocardiografía

  • Cano Serrano, J.
  • Alcaraz Martinez, R.
  • Rieta, J J|||0000-0002-3364-6380
[ES] Las enfermedades cardiovasculares son una de las principales causas de muerte, siendo la hipertensión arterial (HTA) su principal factor de riesgo. Sus complicaciones pueden evitarse con un tratamiento temprano, pero dado que estos pacientes no presentan ninguna sintomatología, a menudo la HTA se detecta en estadios muy avanzados. Este trabajo presenta un modelo de estimación de la presión arterial (PA) a partir de señales de electrocardiografía (ECG) y fotopletismografía (PPG), que pueden obtenerse del paciente con facilidad mediante dispositivos llevables de monitorización continua. Se han analizado señales de 86 pacientes con registros de ECG, PPG y PA, siendo 35 normotensos, 26 prehipertensos y 25 hipertensos. Los registros fueron limpiados de ruido para mejorar la obtención de sus puntos característicos. A partir de ellos se obtuvieron parámetros discriminatorios como los tiempos de llegada de pulso (PAT) y características morfológicas de la señal PPG como el ancho del pulso e intervalo entre picos sistólicos, con los que se entrenarán modelos de clasificación buscando mejorar los resultados de discriminación entre pacientes. Los resultados obtenidos fueron del 85,44 % de F1 score comparando a pacientes normotensos con prehipertensos e hipertensos, logrando una mejora del 7 % respecto a la utilización de parámetros predictivos y clasificadores propuestos en estudios previos. La utilización de las señales PPG y ECG ha demostrado ser capaz de discriminar entre personas sanas e hipertensas y, por tanto, podría ser usada para la prevención de la hipertensión implementando esta técnica en dispositivos llevables., El presente trabajo ha sido cofinanciado por los proyectos de investigación competitiva DPI2017-83952-C3 de MINECO-AEI-FEDER-UE, SBPLY/17/180501/000411 de la JCCLM y AICO/2019/036 de la GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Reference database and performance evaluation of methods for extraction of atrial fibrillatory waves in the ECG

  • Alcaraz, Raul
  • SORNMO, LEIF
  • Rieta, J J|||0000-0002-3364-6380
[EN] Objective: This study proposes a reference database, composed of a large number of simulated ECG signals in atrial fibrillation (AF), for investigating the performance of methods for extraction of atrial fibrillatory waves (f -waves). Approach: The simulated signals are produced using a recently published and validated model of 12-lead ECGs in AF. The database is composed of eight signal sets together accounting for a wide range of characteristics known to represent major challenges in f -wave extraction, including high heart rates, high morphological QRST variability, and the presence of ventricular premature beats. Each set contains 30 5 min signals with different f -wave amplitudes. The database is used for the purpose of investigating the statistical association between different indices, designed for use with either real or simulated signals. Main results: Using the database, available at the PhysioNet repository of physiological signals, the performance indices unnormalized ventricular residue (uVR), designed for real signals, and the root mean square error, designed for simulated signals, were found to exhibit the strongest association, leading to the recommendation that uVR should be used when characterizing performance in real signals. Significance: The proposed database facilitates comparison of the performance of different f -wave extraction methods and makes it possible to express performance in terms of the error between simulated and extracted f -wave signals., This work was supported by project DPI2017-83952-C3 of the Spanish Ministry of Economy, Industry and Competitiveness, project SBPLY/17/180501/000411 of the Junta de Comunidades de Castilla-La Mancha, Grant 'Jose Castillejo' (CAS17/00436) from the Spanish Ministry of Education, Culture and Sport, Grant No. BEST/2017/028 from the Education, Research, Culture and Sports Department of Generalitat Valenciana, European Regional Development Fund, and Grant No. 03382/2016 from the Swedish Research Council.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Optimal channel assignment on dense Wi-Fi networks using Thermodynamic Threshold Accepting

  • Tejedor-Romero, Marino
  • Cruz-Piris, Luis
  • Herranz-Oliveros, David
  • Marsa-Maestre, Iván
  • Gimenez-Guzman, Jose Manuel|||0000-0002-1645-8476
[EN] Channel assignment in Wi-Fi 6 dense networks is a challenging problem which critically impacts the performance of WLAN communications. Although there have been many proposals in the area of IEEE 802.11 channel assignment, LCCS has emerged as the de facto standard for distributed channel selection. Notwithstanding, centralized optimizers overcome the performance of distributed channel assignment algorithms, so their study is of utmost importance. One of the most successful optimization proposals in the state-of-the-art for Wi-Fi 4 is based on simulated annealing (SA). However, SA presents a significant limitation: its parameters must be adjusted manually for each scenario, otherwise yielding suboptimal solutions. In this paper, we propose a new technique for channel assignment optimization of Wi-Fi dense networks, called Thermodynamic Threshold Accepting (TTA), including modifications inspired by Threshold Accepting (TA) and Thermodynamic Simulated Annealing (TSA). With respect to SA, TTA avoids manual tuning, being able to adapt to the specific setting automatically. We evaluate TTA in a dense Wi-Fi model and, compared to SA, we show that our approach reaches optimal results without requiring any prior fine-tuning. We also show that TTA is even able to slightly overcome the performance of an accurately calibrated SA optimizer for the same number of iterations., This publication is part of project TED2021-131387B-I00 funded by MCIN/AEI/10.13039/ 501100011033 and by the European Union NextGenerationEU /PRTR and of project PID2021-123168NB-I00 funded by MCIN/AEI/10.13039/501100011033/FEDER, UE. The work has also been funded by Project SB- PLY/19/180501/000171 of the Junta de Comunidades de Castilla-La Mancha and FEDER, Spain, by Project WiDAI (CM/JIN/2021 004) of the Comunidad de Madrid and University of Alcalá, and by Projects PID2019-104855RB-I00 and PID2019-104129GB-I00/AEI / 10.13039/501100011033 of the Spanish Ministry of Science and Innovation. Finally, this work is part of the research project SBPLY/23/180225/000160, which is funded b
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Synthetic alleles to study MUTE-dependent molecular transitions in stomatal development

  • Illescas-Miranda, Jonatan
  • Saiz-Pérez, Josue
  • de Marcos, Alberto
  • Fenoll, Carmen
  • Mena, Montaña
[EN] Stomatal abundance sets plants' potential for gas exchange, impacting photosynthesis and transpiration and, thus, plant survival and growth. Stomata originate from cell lineages initiated by asymmetric divisions of protodermal cells, producing meristemoids that develop into guard cell pairs. The transcription factors SPEECHLESS, MUTE, and FAMA are essential for stomatal lineage development, sequentially driving cell division and differentiation events. Their absence produces stomataless epidermis, hindering analysis of their roles during lineage development. MUTE drives the transition from proliferating meristemoids to guard mother cells, committed to stomatal fate. We aim to explore the molecular mechanisms underlying MUTE activity, using partial loss-of-function alleles predicted to impair DNA-binding and to potentially alter MUTE transcriptional activity. We engineered mutant allele coding sequences, generated Arabidopsis lines carrying them and analyzed their epidermal and transcriptional phenotypes using microscopy and RNA-seq. Synthetic alleles driven by the MUTE promoter rescued the stomata less phenotype of the seedling-lethal mute-3 mutant, enabling stomata differentiation and resulting in viable, fertile plants. Further examination of the developmental consequences of MUTE partial loss-of-function revealed arrested lineages, reduced stomatal abundance and altered stomatal spacing. Transcriptomic analysis of very young cotyledons from complemented lines indicated that only some MUTE targets require an intact MUTE bHLH domain. Comparison with existing lineage cell-specific transcriptional profiles showed that lineage development in the mutant lines was delayed compared to the wild-type but followed similar gene networks. These synthetic alleles provide new insight into MUTE ability to accurately and timely specify stomata formation., MCIN /AEI /10.13039/501100011033,Grant/Award Number: PID2019-105362RB-I00; MICIU/AEI /10.13039/501100011033and EU FEDER, Grant/Award Number:PID2022-137606NB-I00; Junta de Comunidades de Castilla-La Mancha and EUFEDER, Grant/Award Number: SBPLY/21/180225/000058; UCLM Plan Propio, Grant/Award Number: 2022-GRIN-34125
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Refined Multiscale Entropy Predicts Early Failure in Electrical Cardioversion of Atrial Fibrillation

  • Cirugeda, Eva M.
  • Calero, Sofia
  • Hidalgo, Victor M.
  • Enero, Jose
  • Alcaraz, Raul
  • Rieta, J J|||0000-0002-3364-6380
[EN] Electrical cardioversion (ECV) is a well-established strategy for atrial fibrillation (AF) management. Despite its high initial effectiveness, a high relapsing rate is also found. Hence, identification of patients at high risk of early AF recurrence is crucial for a rationale therapeutic strategy. For that purpose, a set of indices characterizing fibrillatory (f-) waves have been proposed, but they have not considered nonlinear dynamics present at different timescales within the cardiovascular system. This work thus explores whether a multiscale entropy (MSE) analysis of the f-waves can improve preoperative predictions of ECV outcome. Thus, two MSE approaches were considered, i.e., traditional MSE and a refined version (RMSE). Both algorithms were applied to the main f-waves component extracted from lead V1 and entropy values were computed for the first 20 time-scales. As a reference, dominant frequency (DF) and f-wave amplitude (FWA) were also computed. A total of 70 patients were analyzed, and all parameters but FWA showed statistically significant differences between those relapsing to AF and maintaining sinus rhythm during a follow-up of 4 weeks. RMSE reported the best results for the scale 19, improving predictive ability up to an 8% with respect to DAF and FWA. Consequently, investigation of nonlinear dynamics at large time-scales can provide useful insights able to improve predictions of ECV failure, This research was funded by the projects DPI2017-83952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from "Junta de Castilla La Mancha" and AICO/2019/036 from "Generalitat Valenciana".
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

IEEE 802.11 graph models

  • Gimenez-Guzman, Jose Manuel|||0000-0002-1645-8476
  • Marsa-Maestre, Ivan
  • Cruz-Piris, Luis
  • Orden, David
  • Tejedor-Romero, Marino
[EN] There are several recent research lines addressing Wi-Fi network planning and optimiza-tion, both in terms of channel assignment and access point deployment. The problem with these works is that evaluation is usually performed with specific and closed models regarding signal prop-agation, throughput computation, and utility definition. Also, many of the models in the literature make assumptions about the role of wireless stations, or the co-channel interference, which-while being valid in the context of a single research work-makes very difficult to compare different approaches, to re-use concepts from previous mechanisms to create new ones, or to generalize mechanisms to other scenarios. This makes the different research lines in Wi-Fi network planning and optimization progress in an isolated manner.This paper aims to address such a recurring problem by proposing a graph-based generic model for Wi-Fi utility computation in network planning scenarios, as well as providing a collection of scenario graphs which may be used to benchmark different planning and optimization approaches. Experiments are conducted to show the validity of the model and the significance of its features, along with its extensibility to other scenarios., This work has been partially funded by Projects PID2019-10 4855RB-I00/AEI/10.13039/501100011033 and PID2019-10412 9GB-I00/AEI/10.13039/501100011033, by Project SBPLY/19/180501/000171 of the Junta de Comunidades de Castilla-La Mancha and FEDER, by Projects UCeNet (CM/JIN/2019-031) and WiDAI (CM/JIN/2021-004) of the Comunidad de Madrid and University of Alcala, and by H2020-MSCA-RISE project 734922 - CONNECT. The publication is also part of project TED2021-131387B-I00 funded by MCIN/AEI/10.13039/501100011033 and by the European Union "NextGenerationEU"/PRTR and of project PID2021-123168NB-I00 funded by MCIN/AEI/10.13039/50110001103 3/FEDER, UE.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A Newcomer&apos, s Guide to EICS, the Engineering Interactive Computing Systems Community

  • López-Jaquero, Victor Manuel
  • Vatavu, Radu-Daniel
  • Panach, Jose Ignacio
  • Vanderdonckt, Jean
  • Pastor López, Oscar|||0000-0002-1320-8471
[EN] Welcome to EICS, the Engineering Interactive Computing Systems community, PACMHCI/EICS journal, and annual conference! In this short article, we introduce newcomers to the field and to our community with an overview of what EICS is and how it positions with respect to other venues in Human-Computer Interaction, such as CHI, UIST, and IUI, highlighting its legacy and paying homage to past scientific events from which EICS emerged. We also take this opportunity to enumerate and exemplify scientific contributions to the field of Engineering Interactive Computing Systems, which we hope to guide researchers and practitioners towards making their future PACMHCI/EICS submissions successful and impactful in the EICS community., We acknowledge the support of MetaDev2 as the main sponsor of EICS 2019. We would like to thank the Chairs of all the tracks of the EICS 2019 conference, the members of the local organization team, and the web master of the EICS 2019 web site. EICS 2019 could not have been possible without the commitment of the Programme Committee members and external reviewers. This work was partially supported by the Spanish Ministry of Economy, Industry and Competitiveness, State Research Agency / European Regional Development Fund under Vi-SMARt (TIN2016-79100-R), the Junta de Comunidades de Castilla-La Mancha European Regional Development Fund under NeUX (SBPLY/17/180501/000192) projects, the Generalitat Valenciana through project GISPRO (PROMETEO/2018/176), and the Spanish Ministry of Science and Innovation through project DataME (TIN2016-80811-P).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Predicción a Largo Plazo del Resultado de la Ablación Quirúrgica en Fibrilación Auricular Mediante el Uso de una Única Derivación del Electrocardiograma Preoperatorio

  • Martínez Iniesta, M.
  • Escribano Cano, P.
  • García Teruel, M.
  • Ródenas García, J.
  • Hornero Sos, F.
  • Alcaraz Martínez, R.
  • Rieta, J J|||0000-0002-3364-6380
[ES] La ablación quirúrgica (AQ), realizada concomitantemente en pacientes que requieren cirugía a corazón abierto, es el procedimiento más eficaz para controlar la fibrilación auricular (FA). Considerando los importantes efectos secundarios de esta técnica, junto a los beneficios de anticipar una decisión sobre el tratamiento antiarrítmico, la predicción preoperatoria de su resultado a largo plazo supone un interesante reto clínico. Este trabajo introduce un novedoso algoritmo de predicción del resultado de la AQ, transcurrido un año de seguimiento, basado en el análisis de la derivación V1 del electrocardiograma (ECG) preoperatorio. El método extrae de éste las ondas fibrilatorias, segmenta la señal resultante en tramos de 1 s y calcula la desviación estándar de la energía wavelet relativa para la séptima escala (EWR7_DE) contenida en cada uno de ellos. Este índice consiguió una capacidad discriminatoria del 75% entre los pacientes que mantuvieron un ritmo sinusal y aquellos que recayeron a FA durante el seguimiento, superando así en casi un 20% la habilidad de otros parámetros clásicos y convirtiéndose en un prometedor predictor de recurrencia de la FA tras la AQ., Trabajo financiado por los proyectos DPI2017-83952-C3 MINECO/AEI/FEDER, UE, SBPLY/17/180501/000411 de la Junta de Comunidades de Castilla-La Mancha y AICO/2019/036 de la Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Quality Assessment of Very Long-Term ECG Recordings Using a Convolutional Neural Network

  • Huerta, A.
  • Martínez-Rodrigo, A.
  • Bertomeu González, V.
  • Quesada, A.
  • Alcaraz, R.
  • Rieta, J J|||0000-0002-3364-6380
[EN] The electrocardiogram (ECG) is a physiological signal highly sensitive to disturbances during its acquisition. To palliate this issue, many works have described preprocessing algorithms operating in 12-lead, short-term ECG recordings. However, only a few methods have been introduced to detect noisy segments in single-lead, long-term ECG signals, this being a pending challenge to be resolved. Hence, this work proposes a novel technique to automatically detect low-quality segments in single-lead, long-term ECG recordings. The method is based on the high learning capability of a convolutional neural network (CNN), which has been trained with 2D images obtained when turning ECG recordings into scalograms using a continuous Wavelet transform (CWT). To validate the method, a publicly available dataset containing single-lead, long-term ECG intervals from patients with different cardiac rhythms has been used. These signals have been annotated by experts, who identified noisy intervals and those with sufficient quality to be clinically interpreted. The results have shown that the proposed method discriminates correctly between low and high-quality ECG segments with an accuracy greater than 90%, and with sensitivity slightly larger than specificity., This work has been funded by projects DPI2007-83952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501000411 from Junta de Castilla la Mancha, AICO/2019/036 from Generalitat Valenciana, and grand 2018/11744 from European Regional Development Fund (FEDER, UE).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Novel Time-Frequency Features of the Fibrillatory Waves Improve Catheter Ablation Outcome Prediction of Persistent Atrial Fibrillation

  • Escribano, Pilar
  • Ródenas, Juan
  • Arias, Miguel A.
  • Langley, Philip
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Despite its limited long-term success rate, catheter ablation (CA) is still the first-line treatment for patients suffering from persistent atrial fibrillation (AF). Preoperative prediction on the procedure¿s outcome is gaining clinical interest to provide optimized patient selection, limit repeated procedures, hospitalization rates, and treatment costs. To this respect, dominant frequency (DF) and amplitude of fibrillatory waves (f-waves) reflected on the electrocardiogram (ECG) recording have provided promising results. Hence, this work explores the ability of a novel set of frequency and amplitude features of the f-waves to improve CA outcome prediction. More precisely, in addition to DF and normalized f-wave amplitude (NFWA), three indices such as spectral entropy (SE), spectral flatness measure (SFM), and amplitude spectrum area (AMSA) were also analyzed. The results obtained for 204 6 s-length ECG intervals extracted from 51 persistent AF patients showed that all indices found statistically significant differences between the patients who maintained sinus rhythm and those who relapsed to AF after a follow-up of 9 months. However, they only obtained limited a discriminant ability ranging between 55 and 62%, which was overcome by 15¿23% when NFWA, SE and AMSA were combined. Consequently, this combination of frequency and amplitude features of the f-waves seems to provide new insights about the atrial substrate remodeling, which could be helpful in improving preoperative CA outcome prediction. Nonetheless, further studies are required in the future, This research has been supported by grants DPI2007-83952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501000411 from Junta de Comunidades de Castilla-la Mancha and AICO/2019/036 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Deep Learning and Recurrence Information Analysis for the Automatic Detection of Obstructive Sleep Apnea

  • Padovano, Daniele
  • Martinez-Rodrigo, Arturo
  • Pastor, José Manuel
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Obstructive sleep apnea (OSA) represents a significant health concern. While polysomnography (PSG) remains the gold standard, its resource-intensive nature has encouraged the exploration of further alternative approaches. Most of these were based on the heart rate variability (HRV) analysis, but only a few of them have presented a recurrence-based approach. The present paper addresses this gap by integrating convolutional neural networks (CNNs) with HRV recurrence analysis. Employing three different and publicly available databases from PhysioNet's official repository (Apnea-ECG, MIT-BIH, and UCD-DB), the presented method was able to expose concealed patterns within the distance matrix of HRV's phase space, which is discernible at an appropriate level of abstraction through CNNs. Under the challenging context of external validation (MIT-BIH and UCD for training, and Apnea-ECG for testing), the results obtained were comparable to those presented in the state of the art, achieving a peak accuracy of 75%, while maintaining balanced sensitivity and specificity at 74% and 75%, respectively. Moreover, these results obtained by the proposed CNN-based recurrence analysis of HRV also outperformed traditional time-frequency models, which have yielded values of accuracy lower than 65%. Hence, this paper highlights the importance of the proposed method in gaining new insights into OSA's HRV dynamics, offering a contribution that adds to the existing analytical approaches in the state of the art., This research has received financial support from public grants PID2021-128525OB-I00 and PID2021-123804OB-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund (EU), SBPLY/21/180501/000186 from Junta de Comunidades de Castilla-La Mancha, TED2021-130935B-I00, funded by the Spanish Government in conjunction with the European Regional Development Fund (EU), and AICO/2021/286 from Generalitat Valenciana. Moreover, Daniele Padovano holds a predoctoral scholarship 2022-PRED-20642, which is co-financed by the operating program of European Social Fund (ESF) 2014-2020 of Castilla-La Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Model-driven gap analysis for the fulfillment of quality standards in software development processes

  • Giachetti-Herrera, Giovanni Andrés
  • Marín, Beatriz|||0000-0001-8025-0023
  • de la Vara, José Luis
[EN] Society today is moving towards rapid digitalization of almost every aspect of our lives. From healthcare and transport to work or entertainment, we depend on software products that need to function properly. The adequate construction of these software products can be evaluated and certified by means of quality standards. However, adopting quality standards is a complex and time-consuming task that requires experienced practitioners with advanced knowledge about standards and development practices. This presents a dichotomy for development companies that are transitioning to more agile schemes, where the necessary quality knowledge is scarce and poorly documented, and is slowly learnt and applied by novel practitioners. To overcome these issues, this paper presents a model-driven approach to automate the analysis of software development processes that must be aligned to quality standards. The approach has been implemented in an open-source tool and applied to a case study to automatically generate a gap analysis by reusing expert knowledge related to the ISO 9001 standard. The application has demonstrated it is possible to reduce the effort required from expert practitioners to perform the analysis and improve development processes to ensure the fulfillment of specific quality standards., The work leading to this paper received funding from the VALU3S (H2020-ECSEL grant agreement no 876852; Music360 Project (Horizon Europe research and innovation programme) grant agreement No 101094872; MCIN/AEI/10.13039/501100011033 ref. PCI2020-112001; European Union NextGenerationEU/PRTR), REBECCA (HORIZON-KDT agreement no 101097224; MCIN/AEI/10.13039/501100011033 ref. PCI2022-135043-2; European Union NextGenerationEU/PRTR), iRel4.0 (H2020-ECSEL grant agreement no 876659; MCIN/AEI/10.13039/501100011033 ref. PCI2020-112240; European Union NextGenerationEU/PRTR), ETHEREAL (MCIN/AEI/10.13039/501100011033 ref. PID2020-115220RB-C21; ERDF A way of making Europe), and Treasure (JCCM ref. SBPLY/19/180501/000270; EC's ERDF A way of making Europe) projects; the Ramon y Cajal Program (MCIN/AEI/10.13039/501100011033 ref. RYC-2017-22836; ESF Investing in your future); The Valencian Innovation Agency and Innovation through the OGMIOS project (INNEST/2021/57); The Generalitat Valenciana through the CoMoDiD project (CIPROM/2021/023); The Spanish State Research Agency through the DELFOS (PDC2021-121243-I00) and SREC (PID2021-123824OB-I00) projects; MICIN/AEI/10.13039/501100011033; and co-financed with ERDF and the European Union Next Generation EU/PRTR; and SIAM (Chile's CORFO-INNOVA ref.16COTE-60218), and NISUM Technologies in Chile.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Distributed Remote E-Voting System Based on Shamir&apos, s Secret Sharing Scheme

  • Tejedor-Romero, Marino
  • Orden, David
  • Marsa-Maestre, Ivan
  • Junquera-Sanchez, Javier
  • Gimenez-Guzman, Jose Manuel|||0000-0002-1645-8476
[EN] A number of e-voting systems have been proposed in the last decades, attracting the interest of the research community. The challenge is far from being fully addressed, especially for remote systems. In this work, we propose DiverSEC, a distributed, remote e-voting system based on Shamir secret sharing, operations in Galois field and mixnets, which enables end-to-end vote verification. Parties participate as nodes in the network, protecting their interests and ensuring process integrity due to the conflicting interests. The threat model is very conservative, not letting even the most privileged actors to compromise votes privacy or integrity. Security in depth is implemented, overlapping different mechanisms to offer guarantees even in the most adverse operating conditions. The main contributions of the resulting system are our proposal for secret-sharing among the political parties, which guarantees that no party can compromise the integrity of the ballot without being detected and identified in real time, and the computational and architectural scalability of the proposal, which make it easy to implement., M.T.-R. is funded by a predoctoral grant from the University of Alcala. M.T.-R., I.M.-M. and J.M.G.-G. are partially funded by Project PID2019-104855RB-I00/AEI/10.13039/501100011033 of the Spanish Ministry of Science and Innovation, by Project SBPLY/19/180501/000171 of the Junta de Comunidades de Castilla-La Mancha and FEDER and by Project UCeNet (CM/JIN/2019-031) of the Comunidad de Madrid and University of Alcala. D.O. is partially supported by Project PID2019-104129GB-I00/AEI/10.13039/501100011033 of the Spanish Ministry of Science and Innovation, and by H2020-MSCA-RISE project 734922-CONNECT.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Comparative Study of Convolutional Neural Networks for ECG Quality Assessment

  • Huerta, Alvaro
  • Martinez-Rodrigo, Arturo
  • Puchol, Alberto
  • Pachon, Marta, I
  • Alcaraz, Raul
  • Rieta, J J|||0000-0002-3364-6380
[EN] In the last years, convolutional neural networks (CNNs) have become popular in ECG analysis, since they do not require pre-processing stages, nor specific pre-training. However, their ability for ECG quality assessment has still not been thoroughly assessed. Hence, this work introduces a comparison about the ability of several CNN algorithms to classify between high and low-quality ECGs. Taking advantage of the concept of transfer learning, five common pre-trained CNNs were analyzed, such as AlexNet, GoogLeNet, VGG16, ResNet18 and InceptionV3. They were fed with 2-D images obtained by turning 5 second-length ECG segments into scalograms through a continuous Wavelet transform. To train and validate the algorithms, 1,168 noisy ECG intervals, along with other 1,200 ECG excerpts with sufficient quality for their further interpretation, were extracted from a public database. The obtained results showed that all CNNs provided mean values of accuracy between 89 and 91%, but notable difference in terms of computational load were noticed. Thus, AlexNet was the fastest algorithm, requiring notably less CPU usage and memory than the remaining methods. Consequently, this CNN exhibited the best trade-off between high-quality ECG identification accuracy and computational load, and it could be considered as the most convenient algorithm for ECG quality assessment., This research has been supported by the grants DPI2017-83952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha and AICO/2019/036 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A novel wavelet-based filtering strategy to remove powerline interference from electrocardiograms with atrial fibrillation

  • García, M.
  • Martínez, Miguel
  • Ródenas, Juan
  • Alcaraz, R.
  • Rieta, J J|||0000-0002-3364-6380
[EN] Objective: The electrocardiogram (ECG) is currently the most widely used recording to diagnose cardiac disorders, including the most common supraventricular arrhythmia, such as atrial fibrillation (AF). However, different types of electrical disturbances, in which power-line interference (PLI) is a major problem, can mask and distort the original ECG morphology. This is a significant issue in the context of AF, because accurate characterization of fibrillatory waves (f-waves) is unavoidably required to improve current knowledge about its mechanisms. This work introduces a new algorithm able to reduce high levels of PLI and preserve, simultaneously, the original ECG morphology. Approach: The method is based on stationary wavelet transform shrinking and makes use of a new thresholding function designed to work successfully in a wide variety of scenarios. In fact, it has been validated in a general context with 48 ECG recordings obtained from pathological and non-pathological conditions, as well as in the particular context of AF, where 380 synthesized and 20 long-term real ECG recordings were analyzed. Main results: In both situations, the algorithm has reported a notably better performance than common methods designed for the same purpose. Moreover, its effectiveness has proven to be optimal for dealing with ECG recordings affected by AF, sincef-waves remained almost intact after removing very high levels of noise. Significance: The proposed algorithm may facilitate a reliable characterization of thef-waves, preventing them from not being masked by the PLI nor distorted by an unsuitable filtering applied to ECG recordings with AF., Research supported by grants DPI2017-83952-C3 MINECO/AEI/FEDER, UE and SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Towards green game software engineering: A comparative analysis of energy consumption between the widespread unity and unreal video game engines

  • Perez, Carlos
  • Veron, Javier
  • Pérez, Francisca
  • Moraga, Ma Angeles
  • Calero, Coral
  • Cetina Englada, Carlos
[EN] Context: The total energy cost of computing activities is steadily increasing, and projections indicate that it will be one of the dominant global energy consumers in the coming decades. However, the video game sector has not yet developed the same level of environmental awareness as other computing technologies despite the estimated three billion regular video game players in the world. Objective: This work evaluates the energy consumption of the most widely used industry-scale video game engines: Unity and Unreal Engine. Method: Specifically, our work uses three scenarios representing relevant aspects of video games (Physics, Static Meshes, and Dynamic Meshes) to compare the energy consumption of the engines. The aim is to determine the influence of using each engine on energy consumption. Results: Our research has confirmed notable differences in energy consumption: 351% in Physics in favor of Unity, 17% in Static Meshes in favor of Unity, and 26% in Dynamic Meshes in favor of Unreal Engine. Conclusion: Considering the estimated three billion regular video game players worldwide and the high computational requirements of the sector, the magnitude of potential savings is a relevant issue for the research community. This might encourage a new branch of research on energy efficient video game engines., This work was supported in part by the following projects: Project VARIATIVA (Ministry of Economy and Competitiveness (MINECO) through the Spanish National R+D+i Plan and ERDF funds under Grant PID2021-128695OB-I00) ; Research Group ST61_23R. Gobierno de Aragon (Spain) ; Project PHYLOVAR (Ministry of Science, Innovation and Universities (MICIU) through the Spanish National R+D+i Plan and ERDF funds un-der Grants PID2024-162114OB-C21, PID2024-162114OA-C22) , funds from (MICIU/AEI/10.13039/501100011033/) ; OASSIS (PID2021-122554OBC31/AEI/10.13039/501100011033/FEDER, UE) ; EMMA (Project SBPLY/21/180501/000115, funded by CECD (JCCM) and FEDER funds) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Stock control analytics: a data-driven approach to compute the fill rate considering undershoots

  • Babiloni, Eugenia|||0000-0002-7949-3703
  • Guijarro, Ester|||0000-0003-1988-0397
  • Trapero, Juan R.
[EN] One of the most frequently used inventory policies is the order-point, order-up-to-level (s, S) system. In this system, the inventory is continuously reviewed and a replenishment request is placed whenever the inventory position drops to or below the order point, s. The variable replenishment order quantity and the variable replenishment cycle characterize the system by the use of complex mathematical computations. Different methodological approaches diminish the mathematical complexity by neglecting the undershoots, i.e., the quantity that the inventory position is below the order point when it is reached. In this paper, we conceptually and empirically analyse the bias that neglecting the undershoots introduces into the estimation of the fill rate. After that, we suggest a new methodology developed under a data-driven perspective that uses a state-dependent parameter algorithm to correct such a bias. As a result, we propose two new methods, one parametric and the other nonparametric, to enhance the fill rate estimate. Both methods, named analytics fill rate methods, remove the bias that neglecting the undershoots introduces and are used to illustrate the practical implications of this hypothesis on the performance and design of the (s, S) system. This research is developed in a lost sales context with simulated stochastic and i.i.d. discrete demands as well as actual sales data., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This work was supported by the European Regional Development Fund and Junta de Comunidades de Castilla-La Mancha (JCCM/FEDER, UE) under the project with reference SBPLY/19/180501/000151 and by the Vicerrectorado de Investigacion y Politica Cientifica from UCLM through the research group fund program (PREDILAB; [2021-GRIN-31210]). Funding for open access charge: CRUE-Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Fortification and bioaccessibility of saffron apocarotenoids in potato tubers.

  • Gómez Gómez, Lourdes
  • Morote, Lucía
  • Frusciante, Sarah
  • Diretto, Gianfranco
  • Niza, Enrique
  • López-Jiménez, Alberto José
  • Mondejar, María
  • Rubio-Moraga, Ángela
  • Ardangoña, Javier
  • Martin-Belmonte, Alejandro
  • Luján, Rafael
  • Ahrazem, Oussama
  • Rambla Nebot, Jose Luis
  • Presa Castro, Silvia
  • GRANELL RICHART, ANTONIO|||0000-0003-4266-9581
[EN] Carotenoids are C40 isoprenoids with well-established roles in photosynthesis, pollination, photoprotection, and hormone biosynthesis. The enzymatic or ROS-induced cleavage of carotenoids generates a group of compounds named apocarotenoids, with an increasing interest by virtue of their metabolic, physiological, and ecological activities. Both classes are used industrially in a variety of fields as colorants, supplements, and bio-actives. Crocins and picrocrocin, two saffron apocarotenoids, are examples of high-value pigments utilized in the food, feed, and pharmaceutical industries. In this study, a unique construct was achieved, namely O6, which contains CsCCD2L, UGT74AD1, and UGT709G1 genes responsible for the biosynthesis of saffron apocarotenoids driven by a patatin promoter for the generation of potato tubers producing crocins and picrocrocin. Different tuber potatoes accumulated crocins and picrocrocin ranging from 19.41-360 to 105-800 mu g/g DW, respectively, with crocetin, crocin 1 [(crocetin-(beta-D-glucosyl)-ester)] and crocin 2 [(crocetin)-(beta-D-glucosyl)-(beta-D-glucosyl)-ester)] being the main compounds detected. The pattern of carotenoids and apocarotenoids were distinct between wild type and transgenic tubers and were related to changes in the expression of the pathway genes, especially from PSY2, CCD1, and CCD4. In addition, the engineered tubers showed higher antioxidant capacity, up to almost 4-fold more than the wild type, which is a promising sign for the potential health advantages of these lines. In order to better investigate these aspects, different cooking methods were applied, and each process displayed a significant impact on the retention of apocarotenoids. More in detail, the in vitro bioaccessibility of these metabolites was found to be higher in boiled potatoes (97.23%) compared to raw, baked, and fried ones (80.97, 78.96, and 76.18%, respectively). Overall, this work shows that potatoes can be engineered to accumulate saffron apocarotenoids that, when consumed, can potentially offer better health benefits. Moreover, the high bioaccessibility of these compounds revealed that potato is an excellent way to deliver crocins and picrocrocin, while also helping to improve its nutritional value., This work was supported by grants BIO2016-77000-R and PIB2020-114761RB-I00 from Ministerio de Ciencia e Innovacion (MCIN), SBPLY/17/180501/000234 and SBPLY/21/180501/000012 from the Junta de Comunidades de Castilla-La Mancha (co-financed European Union FEDER funds) to LG and OA, and SBPLY/17/180501/000229 and SBPLY/21/180501/000064 from the Junta de Comunidades de Castilla-La Mancha (co-financed European Union FEDER funds) to RL and Margarita Salas fellowship from Ministerio de Universidades and Universidad de Castilla-La Mancha to AM-B. JR was supported by the Spanish Ministry of Science and Innovation through a "Juan de la Cierva-Incorporacion" grant (IJC2020-045612-I).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

A Straightforward Methodology to Distinguish Complex Fractionated Atrial Electrograms of Paroxysmal from Persistent Atrial Fibrillation

  • Finotti, Emanuela
  • Ciaccio, Edward J.
  • Garan, Hasan
  • Bertomeu-González, Vicente
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Many indices aimed at discriminating between paroxysmal and persistent atrial fibrillation (ParAF vs. PerAF) have been previously studied and assessed via statistical tests in order to suggest optimized approaches to catheter ablation (CA) of AF. However, clinicians demand the use of simple classification methods of straightforward comprehension. The present work exploits AF cycle length (AFCL), dominant frequency (DF), sample entropy (SE) and determinism (DET) of recurrent quantification analysis, applied to AF recordings of complex fractionated atrial electrograms (CFAEs), aimed at creating straightforward models to discriminate between ParAF and PerAF. AFCL and DF were calculated on the full AF recordings, whereas SE and DET were computed on segments of 1, 2 and 4s. First, correlation matrix filters removed redundant information and Random Forests made a ranking of variables by relevance. Next, coarse tree classificators were created, combining optimally high-ranked indexes which were tested with leave-one-out cross-validation. After analyzing all the possible combinations of highly ranked features, the best classification performance provided an Accuracy (Acc) of 88.2% to discriminate ParAF from PerAF, while DET provided the highest single Acc of 82.4%. As conclusion, the careful selection of limited sets of indices feeding straightforward classificators are able to discriminate accurately between CFAEs of ParAF and PerAF., Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2019/036 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Confiabilidad de las Ondas de Activación Local para Evaluar el Sustrato Auricular de Pacientes con Fibrilación Auricular Paroxística

  • Vraka, A.
  • Hornero Sos, F.
  • Bertomeu-González, V.
  • Osca Asensi, J.
  • Alcaraz Martínez, R.
  • Rieta, J J|||0000-0002-3364-6380
[ES] El análisis de electrogramas (EGMs) del seno coronario (SC) durante la ablación por catérer (AC) de fibrilación auricular (FA) es clave para la evaluación del sustrato auricular. No obstante, los canales del catéter de registro suelen verse afectados por mal contacto y por el movimiento cardíaco. Este trabajo estudia los canales más fiables para preservar las dinámicas de la FA durante el ritmo sinusal (RS). Se han empleado 44 registros bipolares multicanal del SC de 60-300 segundos de 28 pacientes con FA paroxística sometidos a AC. Cada registro contenía cinco canales: distal, medio-distal, medio, medio-proximal, proximal. En cada canal se calcularon características de las ondas de activación local (OALs): duración, área y correlación entre morfologías dominantes. Se han utilizado los tests de KruskalWallis, Mann-Whitney y Mann-Whitney con corrección de Bonferroni para la comparación multicanal, por pares y uno frente a los demás, respectivamente. El canal distal presentó resultados menos fiables, con OALs de duración larga (p = 0,047), amplitud baja (pmax < 0,003) y menos área (pmax < 0,020) y con correlación entre sus OALs y las OALs del canal proximal relativamente baja (85,57 %). Las OALs entre los canales medio y medio-próximal fueron más consistentes, con correlación entre sus OALs muy altas (95,02 %), presentando además duración más corta (p = 0,084) y amplitud (pmax < 0,050) y áreas mayores (pmax < 0,070). En consecuencia, los canales medios y medio-proximales son más robustos, preservando al máximo las dinámicas de la FA, por ello se aconseja su empleo para evaluar el sustrato auricular de pacientes con FA durante el RS., Trabajo cofinanciado por los proyectos de investigación competitiva DPI2017-83952-C3 de MINECO-AEIFEDER-UE, SBPLY/17/180501/000411 de la JCCLM y AICO/2019/036 de la GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Preoperative Prediction of Catheter Ablation Outcome in Persistent Atrial Fibrillation Patients through Spectral Organization Analysis of the Surface Fibrillatory Waves

  • Escribano Cano, Pilar
  • Ródenas, Juan
  • García, Manuel
  • Arias, Miguel A.
  • Hidalgo, Víctor M.
  • Calero, Sofía
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Catheter ablation (CA) is a commonly used treatment for persistent atrial fibrillation (AF). Since its medium/long-term success rate remains limited, preoperative prediction of its outcome is gaining clinical interest to optimally select candidates for the procedure. Among predictors based on the surface electrocardiogram, the dominant frequency (DF) and harmonic exponential decay (gamma) of the fibrillatory waves (f-waves) have reported promising but clinically insufficient results. Hence, the main goal of this work was to conduct a broader analysis of the f-wave harmonic spectral structure to improve CA outcome prediction through several entropy-based measures computed on different frequency bands. On a database of 151 persistent AF patients under radio-frequency CA and a follow-up of 9 months, the newly introduced parameters discriminated between patients who relapsed to AF and those who maintained SR at about 70%, which was statistically superior to the DF and approximately similar to gamma. They also provided complementary information to gamma through different combinations in multivariate models based on lineal discriminant analysis and report classification performance improvement of about 5%. These results suggest that the presence of larger harmonics and a proportionally smaller DF peak is associated with a decreased probability of AF recurrence after CA., This research received financial support from public grants PID2021-00X128525-IV0, PID2021-123804OB-I00, and TED2021-130935B-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund (EU), SBPLY/17/180501/000411 and SBPLY/21/180501/000186 from Junta de Comunidades de Castilla-La Mancha, and AICO/2021/286 from Generalitat Valenciana. Moreover, Pilar Escribano holds a predoctoral scholarship 2020PREDUCLM-15540, which is co-financed by the operating program of the European Social Fund (ESF) 2014-2020 of Castilla-La Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Hypertension Risk Assessment from Photoplethysmographic Recordings Using Deep Learning Classifiers

  • Cano, Jesús
  • Bertomeu-González, Vicente
  • Fácila, Lorenzo
  • Zangróniz, Roberto
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Regular monitoring of blood pressure (BP) is essential for early detection of cardiovascular diseases caused by hypertension, a potentially deadly condition without symptoms in its first stages. This study investigates whether deep learning techniques can assess risk levels of BP using only photoplethysmographic (PPG) recordings without the need of electrocardiographic (ECG) recordings, as in many previous studies. 15.240 segments from 50 different patients containing simultaneous PPG and arterial blood pressure (ABP) signals were analysed. GoogleNet and ResNet pretrained convolutional neural networks (CNN) with the scalogram of PPG signals obtained by continuous wavelet transform (CWT) used as input images were employed for the classification. The highest F1 score was achieved by discriminating normotensive (NT) patients from prehypertensive (PH) and hypertensive (HT), being 92.10% for GoogleNet and 93.91% for ResNet, respectively. In addition, intra-patient classification using different data segments for training and validation provided an F1 score of 90.28% with GoogleNet and 89.04% with ResNet. Time frequency transformation of PPG recordings to feed deep learning classifiers has been able to provide outstanding results in hypertension risk assessment without requiring either ECG recordings or feature extraction., Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2021/286 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Application of Deep Neural Network Models for Blood Pressure Classification based on Photoplethysmograpic Recordings

  • Cano, Jesús
  • Fácila, Lorenzo
  • Langley, Philip
  • Zangróniz, Roberto
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] The measurement of blood pressure (BP) in an uninterrupted and comfortable way for the subject is essential for early diagnosis and monitoring of cardiovascular diseases (CVD). In fact, hypertension is the main risk factor for CVD because, being a hidden health problem with no symptoms until late stages of the disease are reached. This work investigates whether deep neural network models are able to discriminate between healthy and hypertensive subjects based on photoplethysmographic (PPG) recordings, without the need of electrocardiographic (ECG) recordings as well as avoiding manual morphological feature extraction, as has been popularly used in many previous studies. Recordings analyzed consisted of 635 simultaneous PPG and arterial blood pressure (ABP) signals from 50 different patients. The classification was performed with GoogLeNet, ResNet-18 and ResNet-50 pretrained convolutional neural networks (CNN) using as input images the scalogram of PPG segments obtained by continuous wavelet transformation (CWT). Additionally, Adam and SGDM training solvers were used to compare classification performance. After applying early stopping to avoid overfitting, training was performed with more than half of the epochs using Adam optimizer. ResNet-18 CNN provided the highest classification performance with sensitivity of 95.68%, specificity of 93.65%, F1-score of 95.61% an Area under the Roc area of 98.77%. Hence, the application of deep neural network classification models using time frequency transformation of PPG recordings has been able to provide outstanding results in blood pressure classification without requiring neither morphological feature extraction nor ECG features., Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2021/286 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Thorough Assessment of a P-wave Delineation Algorithm Through the Use of Diverse Electrocardiographic Databases

  • Ruiz, Antonio
  • Arias, Miguel A.
  • Pachón, María Inmaculada
  • Langley, Philip
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Detailed analysis of the electrocardiogram (ECG) recording allows to obtain relevant information about the heart state and its behavior. Indeed, the P-wave study has proven to be helpful in diagnosing many atrial electrical conduction disorders. However, manual delineation of this wave is a very time-consuming task, and a wide variety of automatic algorithms have been proposed for that purpose. The performance of these methods has been mostly validated on the QT database, since it contains manual annotations from clinical experts and is freely available at PhysioNet. Unfortunately, in the last years several authors have shown some major limitations of this database and this work hence presents a more robust validation of a previously published P-wave delineator. Thus, two novel databases which have been very recently made available to the scienti¿c community have been analyzed. The results show that the methods ability to detect P-waves is close to 100% in stable sinus rhythm episodes, but it decreases to 94% when the heart rhythm is irregular or consecutive P-waves exhibit notable morphological variations. Regarding the error between the annotations obtained automatically and those available as a reference, no relevant differences have been observed in terms of standard deviation, thus suggesting that the algorithm achieves a consistent delineation of the P-waves. Contrarily, a notable error has been noticed in average values, thus highlighting the need of a more extensive training for the P-wave delineator than that offered by the QT database., Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2019/036 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Limb Versus Precordial ECG Leads as Improved Predictors of Electrical Cardioversion Outcome in Persistent Atrial Fibrillation

  • Cirugeda, Eva M.
  • Calero, Sofia
  • Quesada, Aurelio
  • Hidalgo, Victor M.
  • Alcaraz, Raul
  • Rieta, J J|||0000-0002-3364-6380
[EN] Electrical cardioversion (ECV) is an effective and low-cost rhythm control strategy for persistent atrial fibrillation (AF). Because of its limited mid- and long-term success rates, prediction of early failure could avoid patients with reduced chance to maintain sinus rhythm (SR). To this end and due to its proximity to the right atrium, several indices characterizing atrial activity have been proposed based on lead V1. However, information from other leads has been discarded to date. Hence, this work studies how effective some common indices computed over the whole set of 12 standard ECG leads are in predicting ECV outcome. Precisely, amplitude, dominant frequency, and sample entropy were computed from the fibrillatory (f-) waves extracted for each one of 12 standard leads acquired before ECV from 58 patients in persistent AF. The classification between the patients who relapsed to AF and maintained sinus rhythm after a follow-up of 4 weeks achieved by these parameters was better from limb lead II than from V1, thus reporting improvements about 6 and 12%. As a consequence, characterization of f-waves from the more accessible limb lead II has proven to be the best choice to improve AF ECV outcome prediction from the ECG., This research was funded by the projects DPI2017-83952C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from "Junta de Castilla La Mancha" and AICO/2019/036 from "Generalitat Valenciana".
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Efecto de la Ablación por Catéter Sobre Ciertas Estructuras Auriculares de Pacientes con Fibrilación Auricular Paroxística: El Caso del Seno Coronario

  • Vraka, A.
  • Bertomeu-González, V.
  • Hornero Sos, F.
  • Quesada Dorador, A.
  • Alcaraz Martínez, R.
  • Rieta, J J|||0000-0002-3364-6380
[ES] Numerosos estudios previos han reportado alteraciones significativas de varias características de la onda P en el electrocardiograma (ECG) de superficie tras un procedimiento de ablacion por cateter (AC) de fibrilación auricular paroxística (FAP). Sin embargo, no se ha reportado resultado alguno sobre una de las estructuras auriculares mas empleada como referencia en el registro de señales invasivas durante procedimientos de AC, como es el seno coronario (SC). Para indagar en este asunto, este estudio utiliza registros bipolares del SC de 26 pacientes sometidos a AC de FAP. Los registros fueron grabados en ritmo sinusal (RS) y duraron 5 minutos. El trabajo incluye la deteccion y el analisis de las siguiente características de ondas de activacion local (OALs): duracion, amplitud, ¿ area positiva y negativa, variabilidad morfologica (VM), dispersión y el número de tramos crecientes y decrecientes (NTCD). Las características mencionadas se compararon antes y despues de la AC usando el test U de Mann-Whitney, calculando tambien sus valores medianos. Duracion, amplitud y áreas positivas y negativas marcaron un moderado decrecimiento (de ¿1,42 % a ¿14,28 %). La VM y la dispersion se incrementaron (de +1,20 % a +64,81 %). No se encontro ninguna alteracion en el NTCD. En consecuencia, los resultados obtenidos coincidieron en su mayor parte con hallazgos similares reportados sobre la onda P del ECG en trabajos previos. No obstante, las características de las OALs en registros bipolares del SC no sufrieron una alteracion significativa por causa de la AC (p > 0,05). En consecuencia, las mayores alteraciones observadas en estudios sobre la onda P del ECG deben provenir, posiblemente, de otras areas auriculares alejadas del SC o son ¿ una superposicion de alteraciones de menor nivel que tienen lugar en multiples zonas auriculares., El presente trabajo ha sido cofinanciado por los proyectos de investigacion competitiva DPI2017-83952-C3 de MINECO-AEI-FEDER-UE, SBPLY/17/180501/000411 de la JCCLM y AICO/2019/036 de la GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Comparative Study of Methods for Cycle Length Estimation in Fractionated Electrograms of Atrial Fibrillation

  • Osorio, Diego
  • Vraka, Aikaterini
  • Moreno-Arribas, José
  • Bertomeu-González, Vicente
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Atrial cycle length (CL) is an important feature for the analysis of electrogram (EGM) characteristics acquired during catheter ablation (CA) of atrial fibrillation (AF), the commonest cardiac arrhythmia. Nevertheless, a robust ACL estimator requires the precise detection of local activation waves (LAWs), which still remains a challenge. This work aims to compare the performance in (CL) estimation, especially under fractionated EGMs, of three different LAW detection methods relying on different operation strategies. The methods are based on the hyperbolic tangent (HT) function, an adaptive amplitude threshold (AAT) and a (CL) iteration (ACLI), respectively. For each method, LAW detection has been assessed with respect to manual annotations made by two experts and performance has been estimated by confusion matrix and mean and individual (CL) error calculation by EGM types of fractionation. The influence of EGM length on the individual (CL) error has been additionally considered. For the HT method, accuracy, sensitivity and precision were 92.77-100%, while for the AAT and ACLI methods they were 78.89-99.91% for all EGM types. The CL error on the HT method was lower than AAT and ACLI methods (up to 12 ms versus up to 20 ms), with the difference being more prominent in complex EGMs. The HT method also showed the lowest dependency on EGM length, presenting the lowest and least variable error values. Therefore, the HT method achieves higher performance in (CL) estimation in comparison with previous LAW detection techniques. The high robustness and precision demonstrated by this method suggest its implementation on CA mapping devices for a more successful location of ablation targets and improved results during CA procedures., This research has received financial support from public grants PID2021-123804OB-I00 and PID2021-00X128525-IV0 of the Spanish Government with DOI 10.13039/501100011033 jointly with the European Regional Development Fund (EU), and regional grants SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha and AICO/2021/286 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Valorization of transgenic Tomaffron-based products enriched in saffron apocarotenoids

  • Lobato-Gómez, Maria
  • Zacarías-García, Jaime
  • Noguera-Artiaga, Luis
  • Pérez-Beser, Jose
  • Gómez-Gómez, Lourdes
  • Rambla Nebot, Jose Luis
  • Orzáez Calatayud, Diego Vicente
  • GRANELL RICHART, ANTONIO|||0000-0003-4266-9581
[EN] Saffron spice (Crocus sativus L.) is highly valued for its bioactive apocarotenoids, including crocins, picrocrocin, and safranal, but its commercial production is limited due to labor-intensive cultivation. In this study, Tomaffron, a transgenic tomato-based platform enriched with saffron apocarotenoids, has been processed into different tomato products to assess their suitability as carriers of these valuable apocarotenoids. Their composition, antioxidant capacity, and sensory attributes were analyzed, with particular attention paid to saffron apocarotenoid stability during processing and storage. Tomaffron-processed products retained or increased the levels of saffron apocarotenoids, with crocin accumulation remaining stable during storage. Picrocrocin and safranal levels remained stable or increased, and sensory tests confirmed that these products replicated the saffron-like flavor. This work highlights the potential of Tomaffron for delivering saffron apocarotenoids in stable, readyto-consume food matrices. These findings support the feasibility of developing functional food prototypes enriched in valuable plant secondary metabolites using metabolic engineering., We thank Silvia Presa, Ana Espinosa, and Teresa Caballero for their technical support. This work was supported by HARNESSTOM, contract number 101000716 Innovation Action EC-H2020-SFS-2020-1, the Ministerio de Ciencia e Innovacion (Spain) through Agencia Estatal de Investigacion (PID2022-141438OB-I00) , and the Junta de Comunidades de Castilla-La Mancha (Spain) , co-financed with the European Union FEDER funds (SBPLY/21/180501/000064) . M.L.G. and A.G. are par-ticipants of the European COST action CA18210 (ROXY) . The UCLM and the IBMCP researchers constitute the Associated Unit TOMAFRAN. M.L. G acknowledges the ACIF-2021 fellowship (GVA, Generalitat <STRONG>Valenciana, Spain) . JL.R. acknowledges funding from the Spanish Ministry of Science and Innovation through a Juan de la Cierva incor-poration grant (IJC2020-045612-I).</STRONG>
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Bayesian multilevel random-effects model for estimating noise in image sensors

  • Riutort-Mayol, Gabriel
  • Gómez-Rubio, Virgilio
  • López-Quílez, Antonio
  • Marqués-Mateu, Ángel|||0000-0003-1343-103X
  • Lerma, José Luis|||0000-0001-9443-9214
[EN] Sensor noise sources cause differences in the signal recorded across pixels in a single image and across multiple images. This study presents a Bayesian approach to decomposing and characterising the sensor noise sources involved in imaging with digital cameras. A Bayesian probabilistic model based on the (theoretical) model for noise sources in image sensing is fitted to a set of a time-series of images with different reflectance and wavelengths under controlled lighting conditions. The image sensing model is a complex model, with several interacting components dependent on reflectance and wavelength. The properties of the Bayesian approach of defining conditional dependencies among parameters in a fully probabilistic model, propagating all sources of uncertainty in inference, makes the Bayesian modelling framework more attractive and powerful than classical methods for approaching the image sensing model. A feasible correspondence of noise parameters to their expected theoretical behaviours and well-calibrated posterior predictive distributions with a small root mean square error for model predictions have been achieved in this study, thus showing that the proposed model accurately approximates the image sensing model. The Bayesian approach could be extended to formulate further components aimed at identifying even more specific parameters of the imaging process., The authors gratefully acknowledge the support from the Instituto de Salud Carlos III and FEDER, project PI18/00881, as well as grants PPIC-2014-001 and SBPLY/17/180501/000491/1 funded by Consejería de Educación, Cultura y Deportes (JCCM) and FEDER.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Combination of frequency- and time-domain characteristics of the fibrillatory waves for enhanced prediction of persistent atrial fibrillation recurrence after catheter ablation

  • Escribano, Pilar
  • Ródenas, Juan
  • García, Manuel
  • Arias, Miguel A.
  • Hidalgo, Víctor M.
  • Calero, Sofía
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Catheter ablation (CA) remains the cornerstone alternative to cardioversion for sinus rhythm (SR) restoration in patients with atrial fibrillation (AF). Unfortunately, despite the last methodological and technological advances, this procedure is not consistently effective in treating persistent AF. Beyond introducing new indices to characterize the fibrillatory waves (f -waves) recorded through the preoperative electrocardiogram (ECG), the aim of this study is to combine frequency- and time -domain features to improve CA outcome prediction and optimize patient selection for the procedure, given the absence of any study that jointly analyzes information from both domains. Precisely, the f -waves of 151 persistent AF patients undergoing their first CA procedure were extracted from standard V1 lead. Novel spectral and amplitude features were derived from these waves and combined through a machine learning algorithm to anticipate the intervention midterm outcome. The power rate index (phi), which estimates the power of the harmonic content regarding the dominant frequency (DF), yielded the maximum individual discriminant ability of 64% to discern between individuals who experienced a recurrence of AF and those who sustained SR after a 9 -month follow-up period. The predictive accuracy was improved up to 78.5% when this parameter phi was merged with the amplitude spectrum area in the DF bandwidth (AMSALF) and the normalized amplitude of the f -waves into a prediction model based on an ensemble classifier, built by random undersampling boosting of decision trees. This outcome suggests that the synthesis of both spectral and temporal features of the f -waves before CA might enrich the prognostic knowledge of this therapy for persistent AF patients., This research was financially supported from public grants PID2021-00X128525-IV0, PID2021-123804OB-I00, and TED2021-130935B-I00 of the Spanish Government 10.13 039/501100011033 jointly with the European Regional Development Fund (EU) , SBPLY/21/180501/000186 from Junta de Comunidades de Castilla-La Mancha, and AICO/2021/286 from Generalitat Valenciana. Furthermore, Pilar Escribano holds a 2020-PREDUCLM-15540 predoctoral scholarship, co-financed by the operating program of the European Social Fund (ESF) 2014-2020 of Castilla-La Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

On the Generalization of Sleep Apnea Detection Methods Based on Heart Rate Variability and Machine Learning

  • Padovano, Daniele
  • Martínez-Rodrigo, Arturo
  • Pastor, José M.
  • Alcaraz, Raul
  • Rieta, J J|||0000-0002-3364-6380
[EN] Obstructive sleep apnea (OSA) is a respiratory disorder highly correlated with severe cardiovascular diseases that has unleashed the interest of hundreds of experts aiming to overcome the elevated requirements of polysomnography, the gold standard for its detection. In this regard, a variety of algorithms based on heart rate variability (HRV) features and machine learning (ML) classifiers have been recently proposed for epoch-wise OSA detection from the surface electrocardiogram signal. Many researchers have employed freely available databases to assess their methods in a reproducible way, but most were purely tested with cross-validation approaches and even some using solely a single database for training and testing procedures. Hence, although promising values of diagnostic accuracy have been reported by some of these methods, they are suspected to be overestimated and the present work aims to analyze the actual generalization ability of several epoch-wise OSA detectors obtained through a common ML pipeline and typical HRV features. Precisely, the performance of the generated OSA detectors has been compared on two validation approaches, i.e., the widely used epoch-wise, k-fold cross-validation and the highly recommended external validation, both considering different combinations of well-known public databases. Regardless of the used ML classifiers and the selected HRV-based features, the external validation results have been 20 to 40% lower than those obtained with cross-validation in terms of accuracy, sensitivity, and specificity. Consequently, these results suggest that ML-based OSA detectors trained with public databases are still not sufficiently general to be employed in clinical practice, as well as that larger, more representative public datasets and the use of external validation are mandatory to improve the generalization ability and to obtain reliable assessment of the true predictive power of these algorithms, respectively., This research has received financial support from public grants PID2021-00X128525-IV0 and PID2021-123804OB-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund, SBPLY/17/180501/000411 and SBPLY/21/180501/000186 from Junta de Comunidades de Castilla-La Mancha, and AICO/2021/286 from Generalitat Valenciana. Moreover, Daniele Padovano holds a predoctoral scholarship 2022-PRED-20642, which is cofinanced by the operating program of European Social Fund (ESF) 2014-2020 of Castilla-La Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Geometry of the modelled freshwater/salt-water interface under variable-density-driven flow (Petrola Lake, SE Spain)

  • Sanz, D.
  • Valiente, N.
  • Dountcheva, I.
  • Muñoz-Martín, A.
  • Gómez-Alday, J. J.
  • Cassiraga, Eduardo|||0000-0001-7567-6986
[EN] Petrola Lake in southeast Spain is one of the most representative examples of hypersaline wetlands in southern Europe. The rich ecosystem and environmental importance of this lake are closely associated with the hydrogeological behaviour of the system. The wetland is fed by the underlying aquifer with relatively fresh groundwater-1 g L-1 of total dissolved solids (TDS)-with a centripetal direction towards the wetland. In addition, the high evaporation rates of the region promote an increase in the concentration of salts in the lake water, occasionally higher than 80 g L-1 TDS. The density difference between the superficial lake water and the regional groundwater can reach up to 0.25 g cm(-3), causing gravitational instability and density-driven flow (DDF) under the lake bottom. The objective of this study was to gain an understanding of the geometry of the freshwater-saltwater interface by means of two-dimensional mathematical modelling and geophysical-resistivity-profile surveys. The magnitude and direction of mixed convective flows, generated by DDF, support the hypothesis that the autochthonous reactive organic matter produced in the lake by biomass can be transported effectively towards the freshwater-saltwater interface areas (e.g. springs in the lake edge), where previous research described biogeochemical processes of natural attenuation of nitrate pollution., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This study was financially supported by a PhD grant to Nicolas Valiente Parra (BES-2012-052256) from the Spanish government, the PEIC-2014-004-P project from the Castilla-La Mancha regional government, and projects CICYT CGL-2008-06373-C03-01 and CICYT CGL2011-29975-C04-02 research projects CGL2017-87216-C4-2-R from the National Research Program I+D+i (FEDER/Ministerio de Ciencia, Investigacion y Universidades), SBPLY/17/180501/000296 from the National Research Program I+D+i of the Junta de Comunidades de Castilla-La Mancha, and by the Regional Government of Madrid through the CARESOIL project (S2018/EMT-4317).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Practical Considerations for the Application of Nonlinear Indices Characterizing the Atrial Substrate in Atrial Fibrillation

  • Finotti, Emanuela
  • Quesada, Aurelio
  • Ciaccio, Edward J.
  • Garan, Hasan
  • Hornero, Fernando
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Atrial fibrillation (AF) is the most common cardiac arrhythmia, and in response to increasing clinical demand, a variety of signals and indices have been utilized for its analysis, which include complex fractionated atrial electrograms (CFAEs). New methodologies have been developed to characterize the atrial substrate, along with straightforward classification models to discriminate between paroxysmal and persistent AF (ParAF vs. PerAF). Yet, most previous works have missed the mark for the assessment of CFAE signal quality, as well as for studying their stability over time and between different recording locations. As a consequence, an atrial substrate assessment may be unreliable or inaccurate. The objectives of this work are, on the one hand, to make use of a reduced set of nonlinear indices that have been applied to CFAEs recorded from ParAF and PerAF patients to assess intra-recording and intra-patient stability and, on the other hand, to generate a simple classification model to discriminate between them. The dominant frequency (DF), AF cycle length, sample entropy (SE), and determinism (DET) of the Recurrence Quantification Analysis are the analyzed indices, along with the coefficient of variation (CV) which is utilized to indicate the corresponding alterations. The analysis of the intra-recording stability revealed that discarding noisy or artifacted CFAE segments provoked a significant variation in the CV(%) in any segment length for the DET and SE, with deeper decreases for longer segments. The intra-patient stability provided large variations in the CV(%) for the DET and even larger for the SE at any segment length. To discern ParAF versus PerAF, correlation matrix filters and Random Forests were employed, respectively, to remove redundant information and to rank the variables by relevance, while coarse tree models were built, optimally combining high-ranked indices, and tested with leave-one-out cross-validation. The best classification performance combined the SE and DF, with an accuracy (Acc) of 88.3%, to discriminate ParAF versus PerAF, while the highest single Acc was provided by the DET, reaching 82.2%. This work has demonstrated that due to the high variability of CFAEs data averaging from one recording place or among different recording places, as is traditionally made, it may lead to an unfair oversimplification of the CFAE-based atrial substrate characterization. Furthermore, a careful selection of reduced sets of features input to simple classification models is helpful to accurately discern the CFAEs of ParAF versus PerAF., This research has received partial financial support from public national grants DPI2017-83952-C3, PID2021-00X128525-IV0, and PID2021-123804OB-I00 of the Spanish Government with DOI 10.13039/501100011033 jointly with the European Regional Development Fund (EU), and regional grants SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha and AICO/2021/286 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Surgical immunization strategies against lateral movement in Active Directory environments

  • Herranz-Oliveros, David
  • Marsa-Maestre, Ivan
  • Tejedor-Romero, Marino
  • de la Hoz, Enrique
  • Gimenez-Guzman, Jose Manuel|||0000-0002-1645-8476
[EN] Lateral movement, in which a cyber attacker progresses through an enterprise network in order to compromise its most valuable assets, is a key stage of any intrusion nowadays. Therefore, being able to mitigate lateral movement, be it by slowing down attacker progress or by limiting its reach, is a top priority for enterprise cyber-defence. Due to the inherent complexity of enterprise networks, it is also a paramount challenge. This challenge becomes even more prominent if we take into account the high impact of deploying security countermeasures on the performance or functionality of the network. In this paper we model lateral movement as an infection process and propose a methodology to prioritize which network elements to protect for a more effective and efficient mitigation. To do this we rely on a graph model and graph theoretic metrics taken from epidemiology research, and apply them to the trust relationships in Microsoft Active Directory infrastructures. We propose selective immunization techniques which act as ``surgical¿¿ countermeasures, by impacting a very reduced ratio of the nodes in the network. Experiments show that the selective immunization strategies we propose effectively mitigate infection spread in these settings while keeping the amount of immunized nodes at a minimum., This work has been partially funded by the project PID2019-104855RB-I00/AEI/10.13039/501100011033 from the Ministry of Science and Innovation of Spain, the project SBPLY/19/180501/000171 from the Government of Castilla-La Mancha (Spain), and the projects UCeNet (CM/JIN/2019-031) and WiDAI (CM/JIN/2021-004) from the Community of Madrid and the University of Alcalá. David Herranz is also funded by an FPU grant from the University of Alcalá. This publication is also part of the TED2021-131387B-I00 project funded by MCIN/AEI/10.13039/501100011033 and the European Union NextGenerationEU /PRTR, and the project PID2021-123168NB-I00 funded by MCIN/AEI/10.13039/501100011033/FEDER, EU.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electrical Cardioversion Outcome Prognosis: A Multivariate Multiscale Entropy Characterization of Atrial Activity in Persistent Atrial Fibrillation

  • Cirugeda Roldan, Eva Maria
  • Plancha, Eva
  • Hidalgo, Victor M.
  • Calero, Sofía
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Background: Atrial fibrillation (AF) remains a significant cause of stroke, heart failure, and cardiovascular morbidity worldwide. Despite advancements in AF management, electrical cardioversion (ECV) remains the most commonly used technique for sinus rhythm (SR) restoration although presenting a limited success rate in the mid-term along with a high number of side-effects which can lead to an increase in patients health deterioration and, consequently, in healthcare costs. Hence, predicting ECV outcome in the mid-term remains a challenging task. Here, a new framework based on multivariate multiscale entropy (MMSE) characterization of atrial activity is proposed to improve ECV outcome prediction in the mid-term. Methods: 58 patients with persistent AF scheduled for ECV were considered. A 12-Lead standard ECG segment of 1.5 min duration prior to the first electrical shock was analyzed. The atrial activity (AA) is estimated from the 12-lead surface ECG using a QT segment removal algorithm based on QRS complex estimation and pattern recognition techniques. AA is characterized by means of multivariate extensions of traditional indices such as the amplitude of the fibrillatory waves and dominant frequency along with multivariate extensions of complexity measures as multivariate Sample Entropy and finally Multivariate Multiscale Entropy (MMSE). These indices were estimated over 12-lead ECG records from 58 ECV derived patients who were classified based on SR maintenance after 30-day follow up (mid-term evaluation). ECV prognosis was evaluated using ROC curves and Youden's Criteria for optimal threshold establishment. Performance was compared to that of unidimensional indices. Results: Patients who maintained SR post-ECV exhibited distinct complexity patterns compared to those who relapsed into AF. Specifically, MMSE provided higher discriminant accuracy than traditional unidimensional indices. When considering only the limb leads in the analysis, the best performance was achieved, over 83% accurate classification of SR restoration in the mid-term (Se = 0.74, Sp = 0.85, p <= 0.001). Additionally, the accumulated entropy and slope of the MMSE curves, offered robust predictors of ECV outcomes providing better balanced sensitivity and specificity ROC curves. Conclusions: This work highlights the importance of multivariate approaches in AF characterization and provides a comprehensive framework for improving ECV outcome prediction, providing an increase in almost a 30% of correct predictions in the mid-term. Future research should explore the integration of these methods into clinical practice to optimize treatment strategies for AF patients and reduced healthcare costs. (c) 2025 AGBM. Published by Elsevier Masson SAS. This is an open access article under the CC BY-NC license (http://creativecommons.org/licenses/by-nc/4.0/)., This work has been supported by: projects: 1) PID2021-128525OB-I00, PID2021-123804OB-I00 and TED2021-130935B-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund 2) SBPLY/21/180501/000186 from Junta de Comunidades de Castilla-La Mancha 3) CIAICO/2023/200 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Análisis multidimensional de las 12 derivaciones del ECG estándar para predecir el éxito de la cardioversión eléctrica en fibrilación auricular persistente

  • Cirugeda Roldan, E.M.
  • Calero Núñez, S.
  • Plancha Burguera, E.
  • Enero Navajo, J.
  • Alcaraz Martínez, R.
  • Rieta, J J|||0000-0002-3364-6380
[ES] La Sociedad Europea de Cardiologia recomienda la cardioversion electrica (CVE) para el control del ritmo cardiaco en situaciones de fibrilacion auricular (FA) persistente. Aunque es capaz de restaurar inicialmente el ritmo sinusal (RS) en la mayoria de los pacientes, su tasa de exito a medio plazo es limitada, presentando la arritmia una alta probabilidad de recurrencia. En este contexto, es de gran interes poder prever el resultado de la CVE, ya que de esta forma se podria tratar individualizadamente a los pacientes. Con este objetivo, durante los ultimos a nos se han propuesto distintos indices que caracterizan la actividad auricular (AA) sobre el electrocardiograma (ECG), tales como la amplitud de las ondas fibrilatorias (f), su frecuencia dominante, o su regularidad. Aunque estos indices han presentado resultados prometedores, solo se han empleado para caracterizar las ondas f en una unica derivacion, generalmente V1, descartando asi la informacion espacial que, registrada en otras derivaciones, puede resultar de gran interes. Asi pues, este trabajo evalua si una extension multidimensional de dichos indices es capaz de incrementar la capacidad de prediccion del resultado de la CVE. En los resultados se observa que las extensiones multidimensionales de los indices propuestos incrementan la prediccion de la CVE hasta casi un 6 %, lo que sugiere que las correlaciones espaciales en la AA de las distintas derivaciones del ECG obtienen informacion predictiva relevante sobre la recurrencia de la FA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Refined Electrical Cardioversion Outcome Prediction with Bipolar Surface Standard Leads for Patients in Persistent Atrial Fibrillation

  • Cirugeda, Eva M.
  • Calero, Sofía
  • Quesada, Aurelio
  • Hidalgo, Víctor M.
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] For persistent atrial fibrillation (AF), a low-cost, simple and effective rhythm control strategy is electrical cardioversion (ECV). This procedure presents high mid- and long-term AF recurrence rates, so anticipation of its outcome could avoid patients with high likelihood of relapsing to AF. To this end and considering the proximity of lead V1 to the right atrium, different parameters assessing fibrillatory (f-) waves reflected on this lead have been recently proposed. However, information from other leads have been mostly discarded. This study hence evaluates the effectiveness of several common parameters computed over the whole set of 12 standard ECG leads to predict ECV outcome with respect to just V1. The results for the amplitude of the f-waves, their dominant frequency and their regularity have shown better predictive abilities from limb lead II than from V1, thus providing improvements between 5 and 12% in the classification rates between patients who relapsed to AF and maintained SR during a follow-up of 4 weeks. Consequently, accessible limb lead II seems to be the best choice to anticipate ECV outcome from the ECG., This research was funded by projects: DPI2017-83952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from "Junta de Castilla la Mancha" and AICO/2019/036 from "Generalitat Valenciana".
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Single-lead electrocardiogram quality assessment in the context of paroxysmal atrial fibrillation through phase space plots

  • Huerta, Alvaro
  • Martínez-Rodrigo, Arturo
  • Bertomeu-González, Vicente
  • Ayo-Martin, Oscar
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Current wearable electrocardiogram (ECG) recording systems have great potential to revolutionize early diagnosis of paroxysmal atrial fibrillation (AF). They are able to continuously acquire an ECG signal for long weeks and then increase the probability of detecting first brief, intermittent signs of the arrhythmia. However, the recorded signal is often broadly corrupted by noise and artifacts, and accurate assessment of its quality to avoid automated misdiagnosis and false alarms of AF is still an unsolved challenge. In this context, the present work is pioneer in exploring the usefulness of transforming the single-lead ECG signal into two common phase space (PS) representations, such as the Poincare plot and the first order difference graph, for evaluation of its quality. Several machine and deep learning models fed with features and images derived from these PS portraits reported a better performance than well-known previous methods, even when they were trained and validated on two separate databases. Indeed, in binary classification of high- and low-quality ECG excerpts, the generated PS-based algorithms reported a discriminant power greater than 85%, misclassifying less than 20% of high-quality AF episodes and non -normal rhythms as noisy excerpts. Moreover, because both PS reconstructions do not require any mathematical transformation, these algorithms also spent much less time in classifying each ECG excerpt in validation and testing stages than previous methods. As a consequence, ECG transformation to both PS portraits enables novel, simple, effective, and computational low-cost techniques, based both on machine and deep learning classifiers, for ECG quality assessment., This research has received financial support from Daiichi Sankyo SLU and from public grants PID2021-00X128525-IV0, PID2021-12380 4OB-I00, and TED2021-130935B-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund (EU) , SBPLY/21/180501/000186 from Junta de Comunidades de Castilla-La Mancha, Spain, and AICO/2021/286 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Deep Learning Detection of Corrupted Segments in Recordings from Wearable Devices to Improve Atrial Fibrillation Screening

  • Huerta, Álvaro
  • Martínez-Rodrigo, Arturo
  • Arias, Miguel A.
  • Langley, Phillip
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in clinical practice. It is associated with an increased risk of cardiovascular events, but its early detection is an unresolved challenge. For that purpose, long-term wearable electrocardiogram (ECG) recording systems are being widely used in the last years, because the arrhythmia often starts with asymptomatic and very short episodes. However, these equipments work in highly dynamics and ever-changing environments, thus providing ECG signals strongly corrupted with different kinds of noises. In this context, ECG quality assessment results essential for a precise and robust AF detection. Hence, this work introduces a deep learning-based algorithm to discern between high- and low-quality segments in single-lead ECG recordings obtained from patients with intermittent AF. The method is based on the high learning capability of a convolutional neural network, which has been trained with 2-D images obtained when turning ECG signals into wavelet scalograms. The obtained results have reported a great ability to discern between high- and low-quality ECG excerpts about 95%, only misclassifying around 6% of clean AF intervals as noisy segments. These outcomes have improved by more than 20% performances of most previous ECG quality assessment algorithms also dealing with AF signals., This research has been supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha, AICO/2019/036 from Generalitat Valenciana and FEDER 2018/11744
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Deciphering the photobehaviour of ensemble and single crystals of Zr-based ITQ MOF composites

  • Caballero-Mancebo, Elena
  • Moreno Rodríguez, José María
  • Cohen, Boiko
  • Douhal, Abderrazzak
  • Corma Canós, Avelino|||0000-0002-2232-3527
  • Díaz, Urbano|||0000-0003-1472-8724
[EN] Understanding the interactions that govern the photophysical behaviour of Metal-organic frameworks (MOFs) and their composites is paramount for their photochemical and photonic applications. In this work, we report on the photobehaviour of Nile Red (NR) adsorbed on the surface of 2D Zr-ITQ-HB (NR@Zr-ITQ-HB) MOF using ultrafast (fs-ns) and single-molecule fluorescence techniques. The results show the occurrence of energy transfer processes happening in 0.34 ns between neighbouring NR molecules, intramolecular charge transfer reaction (similar to 0.6 ps) and a vibrational cooling (10 ps) of the adsorbed dye. Time-resolved single-composite fluorescence microscopy experiments on different NR-loaded composites allowed to resolve the emission from adsorbed aggregates (0.9 ns) and from the charge separated state (2.5 ns) of excited NR. The different photobehaviour of NR adsorbed on ZrO2 nanoparticles indicates the relevance of the Zr-ITQ-HB MOFs surface to the observed photo induced reactions in the composites. We discuss how the nature of both, the organic linkers and metal clusters in this kind of MOFs, affects the photodynamics of the composites. These results may help in designing MOFs "on demand" for their application in photons-based science and technology, like photocatalysis and lighting., This work was supported by MINECO through projects MAT201786532-R, and MAT2017-82288-C2-1-P, and by the JCCM through project SBPLY/19/180501/000212. J.M.M. thanks the predoctoral fellowship from the Severo Ochoa program for support (SEV-20160683), and E.C.-M thanks the MINECO for the FPI fellowship (BES2015-071495).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Metabolic engineering of crocins and picrocrocin apocarotenoids in potato group phureja

  • Gómez-Gómez, Lourdes
  • López-Jimenez, Alberto Jose
  • Fajardo, Cristian Martinez
  • Morote, Lucia
  • Frusciante, Sarah
  • Diretto, Gianfranco
  • Rubio-Moraga, Angela
  • Mondejar-López, Maria
  • Niza, Enrique
  • Argandoña, Javier
  • Granell, Antonio
  • Ahrazem, Oussama
  • Rambla Nebot, Jose Luis
  • Presa Castro, Silvia
[EN] The stigmas of Crocus sativus accumulate the exclusive apocarotenoids crocin and picrocrocin, which are dried and desiccated to make commercial saffron. In addition to providing characteristic organoleptic qualities, saffron apocarotenoids are valuable compounds in the pharmaceutical and health industries. Previously, we developed Desir & eacute;e potato tubers enriched with these apocarotenoids which also showed increased potential benefits for human health. In the current study, Solanum tuberosum (S. tuberosum) Group Phureja 01H15 which accumulates high levels of zeaxanthin, was engineered to produce saffron apocarotenoids to increase the levels of these metabolites in potato tubers using a construct namely O6, which contains the CsCCD2L, UGT74AD1, and UGT709G1 genes necessary for the biosynthesis of crocin and picrocrocin under the control of the patatin promoter. Here, we obtained transgenic S. tuberosum Group Phureja 01H15 lines with high concentrations of crocins and picrocrocin (up to 3.648 mg/g DW, 2.345 mg/g DW, respectively), which were up to 10 and 3 times higher than those obtained in the Desir & eacute;e background, respectively. Furthermore, we performed transcriptome analyses of tubers from Desir & eacute;e and 01H15 wild type and carrying O6 construct. Differentially expressed gene analysis revealed transcript changes not only on tuber carotenoid and apocarotenoid genes but also in other related pathways, suggesting a possible role in isoprenoid metabolism remodeling. Thus, this heterologous system serves as a robust platform for the production of these valuable metabolites.; Transgenic line of Potato Group Phureja exhibiting accumulation of saffron-specific apocarotenoids. image, Ministerio de Ciencia e Innovacion, Grant/Award Numbers: BIO2016-77000-R, PIB2020-114761RB-I00; Junta de Comunidades de Castilla-La Mancha, Grant/Award Numbers: SBPLY/17/180501/000234, SBPLY/21/180501/000012
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Reliable Paroxysmal Atrial Fibrillation Substrate Assessment During Sinus Rhythm Through Optimal Estimation of Local Activation Waves Dynamics

  • Vraka, Aikaterini
  • Hornero, Fernando
  • Quesada, Aurelio
  • Faes, Luca
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] The analysis of coronary sinus (CS) electrograms (EGMs) during catheter ablation (CA) of atrial fibrillation (AF) is highly important for AF substrate evaluation. However, channels of the CS catheter may be affected by vigorous cardiac movement and bad contact. This work investigates the most reliable channels in preserving the AF dynamics during sinus rhythm (SR). Local activation waves (LAWs) were detected in 44 bipolar CS recordings of 60-300 seconds duration in 28 paroxysmal AF patients undergoing CA. Recordings consisted of five channels: distal, mid-distal, medial, mid-proximal and proximal. LAW duration, amplitude, area and correlation between dominant morphologies of each channel were calculated. Multichannel comparison and analysis in pairs of channels were performed using KruskalWallis and Mann-Whitney U-test, respectively. The latter, with Bonferroni correction, was also used for comparison between one and the remaining channels. Median values were calculated. Distal channel presented the longest duration (p = 0.047) and the lowest amplitude LAWs (pmax <; 0.002), with the smallest area (pmax <; 0.020). LAWs in medial were the shortest (p = 0.084) and with the highest amplitude (pmax <; 0.003), followed by LAWs in mid-proximal channel (pmax <; 0.050). The latter, showed the highest area (pmax <; 0.070). LAWs in mid-proximal channel showed the highest correlation with proximal (96.02%) and medial (95.02%) channels, while distal channel contained the least correlated LAWs with medial (85.82%) and proximal (85.57%) channels. Recordings of medial and mid-proximal channels seem to preserve at most the AF dynamics and their analysis is encouraged for studies assessing the AF substrate during SR., Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2019/036 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Parallel Study on Surface and Invasive Recordings Across Catheter Ablation Steps of Paroxysmal Atrial Fibrillation

  • Vraka, Aikaterini
  • Hornero, Fernando
  • Quesada, Aurelio
  • Ravelli, Flavia
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Catheter ablation (CA) is the star treatment of atrial fibrillation (AF). However, important issues regarding its procedure have only been superficially explored. While universal CA effect is assessed, the role of right (RPVI) and left pulmonary vein isolation (LPVI) is ignored. Although coronary sinus (CS) is the prevailing CA reference, how CS itself is modified by CA is unknown. This work evaluates the effect of each ablation step on the atrial substrate and CS funtion. Five-minute lead II and bipolar CS recordings of 29 patients undergoing paroxysmal AF CA were acquired before CA, after LPVI and after RPVI (end of CA). Separate lead II and CS analysis was performed. Duration, amplitude, area and slope rate were calculated for each surface and invasive activation, then signal-averaged. Dispersion, morphology variability (MV) and time-domain heart-rate variability (HRV) features were also calculated. Non-parametric tests were recruited to compare each feature among all and in pairs of different ablation steps with Bonferroni correction. Variation of each feature was calculated in percentages. In surface recordings, duration was significantly shortened after LPVI (¿= -13%, p=0.001) and HRV showed a trend for attenuation (¿< -25%, p< 0.069) after RPVI. In CS recordings, HRV showed an increasing trend after LPVI (¿>+73%, p<0.04S), tending to decrease after RPVI (¿< -33%, p<0.064). Higher dispersion in variations was observed in CS than surface recordings. LPVI causes major alterations in atrial substrate, more prominently observed from lead II analysis. Notwithstanding, HRV variations are better illustrated in CS recordings. A combined analysis of both is recommended., Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2021/286 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Comparative Study on the Generalization Ability of Machine Learning and Deep Learning Algorithms for Quality Assessment of Wearable PPG Recordings

  • Mula Muñoz, Santiago
  • Zangróniz, Roberto
  • Ayo-Martin, Oscar
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] One of the major challenges in using photoplethysmography (PPG) sensors for heart rate monitoring in real-world settings is ensuring signal quality. This work evaluates and compares quality assessment methods using generic machine learning (ML) and deep learning (DL) pipelines, on a unique and comprehensive framework that includes different sensors, wavelengths, measurement locations, and recording environments. The PPG signals from one proprietary and five publicly available datasets were labeled in terms of quality by comparing the PPG-derived heart rate to a reference heart rate estimated from simultaneous electrocardiograms. Diverse techniques based on common ML classifiers and one- and two-dimensional convolutional neural networks (CNN) were trained on a dataset and tested on the remaining ones. The results showed that several generated models performed comparably to previous studies when they were tested on datasets with similar measurement positions and sensors to the training database. Specifically, reductions in sensitivity, specificity, and F1-score of less than 3% from training to testing were observed on some methods. Contrarily, they reported a notably poorer performance when tested on datasets presenting conditions different from the training. Even the best-performing model, based on the well-known, pre-trained CNN AlexNet, experienced a performance drop of over 20% in that situation. These findings show that the analyzed ML and DL methods lack the ability to generalize across PPG signals captured from diverse environments, sensors, wavelengths, and measurement locations. This suggests that developing case-specific methods might be the shortest path towards reliable PPG quality assessment., This work has received financial support from Daiichi Sankyo Company, Limited and from public grants PID2021-128525OB-I00, PID2021-123804OB-I00, and TED2021-130935B-I00 of the Spanish Government 10.13039/501100011033 jointly with the European Regional Development Fund (EU), SB-PLY/21/180501/000186 from Junta de Comunidades de Castilla-La Mancha, and CIAICO/2023/200 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Multi-scale Entropy Evaluates the Proarrhythmic Condition of Persistent Atrial Fibrillation Patients Predicting Early Failure of Electrical Cardioversion

  • Cirugeda Roldan, Eva María
  • Calero, Sofía
  • Hidalgo, Víctor Manuel
  • Enero, José
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] Atrial fibrillation (AF) is nowadays the most common cardiac arrhythmia, being associated with an increase in cardiovascular mortality and morbidity. When AF lasts for more than seven days, it is classified as persistent AF and external interventions are required for its termination. A well-established alternative for that purpose is electrical cardioversion (ECV). While ECV is able to initially restore sinus rhythm (SR) in more than 90% of patients, rates of AF recurrence as high as 20-30% have been found after only a few weeks of follow-up. Hence, new methods for evaluating the proarrhythmic condition of a patient before the intervention can serve as efficient predictors about the high risk of early failure of ECV, thus facilitating optimal management of AF patients. Among the wide variety of predictors that have been proposed to date, those based on estimating organization of the fibrillatory (f-) waves from the surface electrocardiogram (ECG) have reported very promising results. However, the existing methods are based on traditional entropy measures, which only assess a single time scale and often are unable to fully characterize the dynamics generated by highly complex systems, such as the heart during AF. The present work then explores whether a multi-scale entropy (MSE) analysis of thef-waves may provide early prediction of AF recurrence after ECV. In addition to the common MSE, two improved versions have also been analyzed, composite MSE (CMSE) and refined MSE (RMSE). When analyzing 70 patients under ECV, of which 31 maintained SR and 39 relapsed to AF after a four week follow-up, the three methods provided similar performance. However, RMSE reported a slightly better discriminant ability of 86%, thus improving the other multi-scale-based outcomes by 3-9% and other previously proposed predictors of ECV by 15-30%. This outcome suggests that investigation of dynamics at large time scales yields novel insights about the underlying complex processes generatingf-waves, which could provide individual proarrhythmic condition estimation, thus improving preoperative predictions of ECV early failure., This research has been supported by grants DPI2007-83952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501000411 from Junta de Comunidades de Castilla la Mancha and AICO/2019/036 from Generalitat Valenciana.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Application of Deep Learning for Quality Assessment of Atrial Fibrillation ECG Recordings

  • Huerta, Alvaro
  • Martinez-Rodrigo, Arturo
  • Arias, Miguel A.
  • Langley, Philip
  • Alcaraz, Raul
  • Rieta, J J|||0000-0002-3364-6380
[EN] In the last years, atrial fibrillation (AF) has become one of the most remarkable health problems in the developed world. This arrhythmia is associated with an increased risk of cardiovascular events, being its early detection an unresolved challenge. To palliate this issue, long-term wearable electrocardiogram (ECG) recording systems are used, because most of AF episodes are asymptomatic and very short in their initial stages. Unfortunately, portable equipments are very susceptible to be contaminated with different kind of noises, since they work in highly dynamics and ever-changing environments. Within this scenario, the correct identification of free-noise ECG segments results critical for an accurate and robust AF detection. Hence, this work presents a deep learning-based algorithm to identify high-quality intervals in single-lead ECG recordings obtained from patients with paroxysmal AF. The obtained results have provided a remarkable ability to classify between high- and low-quality ECG segments about 92%, only misclassifying around 7% of clean AF intervals as noisy segments. These outcomes have overcome most previous ECG quality assessment algorithms also dealing with AF signals by more than 20%., This research has been supported by the grants DPI2017-83952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from Junta de Comunidades de Castilla-La Mancha, AICO/2019/036 from Generalitat Valenciana and FEDER 2018/11744.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Assessing 1D hydrodynamic modeling of Júcar River behavior in Mancha Oriental Aquifer domain (SE Spain)

  • Dountcheva, Iordanka
  • Sanz, David
  • Penchev, Philip
  • Galabov, Vassil
  • Gómez-Alday, Juan José
  • Cassiraga, Eduardo|||0000-0001-7567-6986
[EN] In times of population growth, climate change, and increasing water scarcity around the world, it is important to take an objective look at water, a fundamental resource for life. Hydrodynamic modeling makes possible the research of different aspects of the water cycle and the evaluation of different hydrological and hydrogeological forecasting scenarios in the short and medium terms. The present research offers a more detailed scope at the hydrodynamic processes and their space-time distributions on a UE pilot in the Jucar River Basin, providing a calibrated and validated hydrodynamic model of 121 km river reach for 45 years period (1974-2019) on a daily scale. The obtained information is about discharge and water depths along the Jucar River reach within the hydrogeological boundaries of the Mancha Oriental Aquifer (MOA). The river-aquifer interactions have been represented as dynamic boundary conditions expressed as a difference between observed discharges measured in 3 gauging stations. The obtained calibration error performance evaluations of observed and simulated values cover two periods, according to observed data availability from gauging station 08036 with resulting R-2 for both discharges and water depths over 0.96. The model validation results were obtained for a different gauge 08132 and the determination coefficients R-2 also perform very well with value of 0.90. The model developed might be useful for decision making in water resources management and can be used to generate simulated time series of water depths, levels, discharges, and velocities in reaches where gauging measurements are not available with a desired space-time resolution (from meter/second to kilometer/month). Estimation of critical discharge value (1.973 m(3)s(-1)) for system equilibrium, based on the balance between losing and gaining sub-reaches of the river, is also made with a statistical significance at 95% for hydrologic years 2007-2010, period influenced by restrictions in groundwater withdrawals. The results of the present research are important for the proper and objective management of the scarce water resources on a watershed scale in Jucar River Basin, a complex case study representing semiarid climate, growing anthropogenic pressures, and complex river-aquifer interactions. The used approach of dynamic representation of the river-aquifer interactions as distributed source boundary condition in the one-dimensional hydrodynamic model might be applied in another study case on similar scale., This work was funded by the following research projects CGL 2017 87216 C 4 2 R Programa Nacional de Investigación I+D+i (FEDER/Ministerio de Ciencia, Investigación y Universidades) SBPLY/17 180501 000296 Programa Nacional de Investigación I+D+i de la Junta de Comunidades de Castilla La Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Reliability of Local Activation Waves Features to Characterize Paroxysmal Atrial Fibrillation Substrate During Sinus Rhythm

  • Vraka, Aikaterini
  • Hornero, Fernando
  • Quesada, Aurelio
  • Faes, Luca
  • Alcaraz, Raul
  • Rieta, J J|||0000-0002-3364-6380
[EN] Analysis of coronary sinus (CS) electrograms (EGMs) is vastly used for the assessment of the atrial fibrillation (AF) substrate. As a catheter consists of five dipoles (distal, mid-distal, medial, mid-proximal, proximal), results may vary upon the employed channel: myocardial contraction and bad contact are unavoidable factors affecting the recording. This work aims to specify the most reliable channels in catching AF dynamics, using 44 multichannel bipolar CS recordings in sinus rhythm (SR) of paroxysmal AF with 1-5 minutes duration. Local activation waves (LAWs) were detected and main features obtained: duration, amplitude, area and correlation between dominant morphologies of each channel. Analysis was performed with Kruskal-Wallis test for multichannel comparison and Mann-Whitney U-test for pairs of channels and comparison between one and the remaining channels, using Bonferroni correction. Median values were calculated. Distal channel presented the highest alteration in LAWs features, being the least correlated channel (82.84 - 88.31%) with the lowest amplitude and area (p(max) < 0.01). Contrastly, medial and mid-proximal channels showed the most robust LAW characteristics, with very high correlation (94.53%) and high area and amplitude values (p(max) < 0.02 and p(max) < 0.07, respectively) and their analysis is recommended for AF substrate characterization during SR, Research supported by grants DPI2017-83952-C3 from MINECO/AEI/FEDER UE, SBPLY/17/180501/000411 from JCCLM and AICO/2019/036 from GVA.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Multidimensional Fibrillatory Waves Analysis for Improved Electrical Cardioversion Outcome Prediction in Persistent Atrial Fibrillation

  • Cirugeda, Eva M.
  • Calero, Sofía
  • Plancha, Eva
  • Enero, José
  • Alcaraz, Raúl
  • Rieta, J J|||0000-0002-3364-6380
[EN] The European Society of Cardiology guidelines recommend electrical cardioversion (ECV) as a rhythm control strategy in persistent atrial fibrillation (AF). Although being able to initially restore sinus rhythm in most patients, mid- and long-term AF recurrence rates are high. In this context, anticipation of ECV outcome is interesting to rationalize the management of AF patients. To this end, several parameters have been recently proposed for atrial activity (AA) characterization, such as fibrillatory wave amplitude (FWA), dominant frequency (DF) and sample entropy (SEn). These indices have revealed promising results, but have been mainly computed from lead V1, thus discarding spatial information from the remaining leads. Hence, this work explores whether a multidimensional extension of these parameters can improve ECV outcome prediction. Results showed that multidimensional parameters provided more balanced values of sensitivity and specificity than unidimensional ones. While FWA and DF showed similar discriminant ability among both approaches, multivariate SEn improved the discriminant ability of its univariate version by 5%, thus predicting 80% of the ECV procedures correctly. Consequently, whereas multivariate extension of linear parameters did not reveal new predictive information, multidimensional entropy analysis was able to quantify novel AA dynamics, which have been helpful in improving ECV outcome prediction., This research was funded by projects DPI2017-83952-C3 from MINECO/AEI/FEDER EU, SBPLY/17/180501/000411 from "Junta de Castilla la Mancha" and AICO/2019/036 from "Generalitat Valenciana".
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Contribución de congreso (ConferenceOutput)

Comparación de Redes Neuronales Preentrenadas para la Evaluación de la Calidad en Registros Electrocardiográficos

  • Huerta Herraiz, A.
  • Martínez Rodrigo, A.
  • Puchol Calderón, A.
  • Pachón Iglesias, M.I.
  • Alcaraz Martínez, R.
  • Rieta, J J|||0000-0002-3364-6380
[ES] Actualmente, es habitual el uso de las redes neuronales convolucionales para el analisis del registro electrocardiografico (ECG). Sin embargo, su capacidad para evaluar la calidad con la que se registra esta senal fisiologica todavia no se ha examinado a fondo. Esta dificil tarea, cuyo objetivo es identificar los intervalos de ECG de baja calidad, podria ayudar a un diagnostico mas preciso de enfermedades cardiacas, especialmente si el ECG se ha registrado con un sistema de monitorizacion a largo plazo portatil o vestible. Asi pues, en este trabajo se introduce un estudio comparativo en el que se analizan varios modelos de redes neuronales en la tarea de discernir entre intervalos de ECG de alta y de baja calidad. Al no existir bases de datos suficientemente extensas, anotadas, y con acceso publico, se comparan tres redes neuronales preentrenadas, las cuales son AlexNet, GoogLeNet y VGGNet. Para ello, se han utilizado 2.000 segmentos de ECG de 5 segundos de duracion, y clasificados en dos grupos de 1.000 segmentos cada uno. Se ha obtenido una validacion robusta de los algoritmos realizando cinco procesos de entrenamiento y dividiendo el conjunto de datos de manera aleatoria, con un 80 % para entrenamiento y un 20 % para test. Los resultados muestran una exactitud generalizada en todos los modelos en torno a un 90 %. Sin embargo, en cuanto al tiempo de calculo y memoria utilizada se han observado importantes diferencias. AlexNet ha mostrado ser el metodo mas rapido para clasificar los segmentos de ECG, mientras que GoogLeNet ha requerido menos memoria. Por lo tanto, ambos algoritmos han demostrado un buen equilibrio entre la identificacion de intervalos de ECG y carga computacional., Este trabajo ha sido cofinanciado por los proyectos de investigacion competitiva DPI2017-83952-C3 de MINECO-AEI-FEDER-UE, SBPLY/17/180501/000411 de la JCCLM, AICO/2019/036 de la GVA y FEDER 2018/11744.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

A random mathematical model to describe the antibiotic resistance depending on the antibiotic consumption: the Acinetobacter baumannii colistin-resistant case in Valencia, Spain

  • Aledo, Juan A.
  • Orengo, Juan C.
  • Andreu-Vilarroig, C.|||0000-0001-5083-4837
  • Cortés, J.-C.|||0000-0002-6528-2155
  • Villanueva Micó, Rafael Jacinto|||0000-0002-0131-0532
[EN] The increase in antibiotic resistance in recent years, mainly due to the non-rational use of antibiotics, is one of the most important global public health threats. In this paper, we propose a mathematical dynamic random model describing the antibiotic resistance evolution of a bacteria and where antibiotic consumption is included is the main driving force in the resistance increase. The random model is solved using the Random Variable Transformation technique and is applied to study the case of Acinetobacter baumannii bacterium resistant to the antibiotic colistin in Valencia, Spain. Using the Multi-Objective Particle Swarm Optimization algorithm, the model has been calibrated with the A. baumannii colistin-resistance and colistin consumption data series. With the optimal model, four possible 7-year future scenarios with different antibiotic consumption trends have been simulated. The model results show how reducing antibiotic consumption does not easily stop the increase in resistance., This work has been funded by the project SBPLY/21/180225/000062 funded by the Government of Castilla-La Mancha and ERDF A way of making Europe. It is also partially funded by MCIN/AEI/10.13039/501100011033 and "ESF Investing your future" through the projects PID2019-106758GB-C33 and PID2020-115270GB-I00. Additionally, it has been funded by the Universitat Politecnica de Valencia PAID-01-22 program under grant 20230185.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Capítulo o parte de un libro (BookPart)

Hydraulic State Estimation: pilot implementation in a water distribution system

  • Ruiz Gómez, Emilio
  • Díaz García, Sarai
  • González Pérez, Javier
[EN] Hydraulic State Estimation (HSE) is an effective tool for water supply systems monitoring. This technique provides the most likely hydraulic state of the network by making use of the available measurements through the system and the associated hydraulic model, enabling to track uncertainty through the process. HSE has been applied to water transport networks before, but extending its application to distribution systems currently constitutes a challenge. The deployment of smart meters offers a unique opportunity to gain distributed information within the distribution level, but it also poses questions regarding the temporal resolution that is available/achievable and how to combine different sources of information. This work presents a real HSE implementation in a Spanish water distribution pilot area (approximately 1,000 inhabitants). Implementation is possible thanks to the systematic measurement of water consumption at each dwelling (with 1 minute and 1 L resolution) and flow and pressure at the inlet to the pilot area. This application is conceived to provide a better understanding of the challenges and opportunities for HSE implementation in water distribution systems., Grant DIN2019-010896 funded by MCIN/AEI /10.13039/ 501100011033. Grant PID2019-111506RBI00 funded by MCIN/AEI /10.13039/ 501100011033. Grant SBPLY/19/180501/000162 funded by Junta de Comunidades de Castilla-La Mancha and ERDF A way of making Europe.