DIGITAL.CSIC. Repositorio Institucional del CSIC
Publication
Artículo científico (JournalArticle)
Tetrahedral DNA nanostructures, graphene and carbon nanodots-based electrochemiluminescent biosensor for BRCA1 gene mutation detection
In this study, we present a novel electrochemiluminescent DNA biosensor designed for detecting breast cancer type 1 (BRCA1) gene mutations. The biosensor integrates graphene nanosheets (Graph-NS), tetrahedral DNA nanostructures (TDNs), and carbon nanodots (CNDs) to enhance sensitivity and specificity. Graph-NS are employed to structure the transducer and serve as a platform for DNA immobilization. TDNs are engineered with a BRCA1 gene-specific capture probe located at the apex (TDN-BRCA1), facilitating efficient biorecognition. Additionally, the basal vertices of TDNs are functionalized with amino groups, enabling their attachment to the CSPE/Graph-NS surface via amino-graphene interaction. This platform effectively identifies single-base mutations in the BRCA1 gene utilizing synthesized CNDs as a coreactant and [Ru(bpy)3]2+ as the luminophore through the coreactant pathway. The developed biosensor demonstrates exceptional sensitivity and can detect a single mutation in the BRCA1 gene. Furthermore, it has been successfully validated in real samples obtained from breast cancer patients, showcasing a remarkable detection limit of 1.41 aM., The Spanish Ministry of Economy and Competitiveness has financially supported this work (PID2020-116728RB-I00, PID2023-150844OB-I00, RED2022-134120-T and TED2021-129738B–I00). Spanish Ministry of Universities supported Laura Gutiérrez-Gálvez with a FPU (FPU19/06309). European Union, through Autonomous Community of Madrid supported Daniel García-Fernández with a Programa Investigo grant in from the Plan de Recuperación, Transformación y Resiliencia– NextGenerationEU (09-PIN1-00013.4/2022-Puesto 83). The authors acknowledge the support of the EU and Horizon 2020 through Instruct Proposal PID: 21859, and the CRIOMECORR project (ESFRI-2019-01-CSIC-16) to the cryoEM CNB-CSIC facility. The authors also appreciate the service from the MiNa Laboratory at IMN, and funding from EU (FEDER, FSE), MINECO (project CSIC13-4E-1794) and CM (project S2018/NMT-4291 TEC2SPACE)., Peer reviewed
Project:
AEI / Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020 PID2020-116728RB-I00
,
AEI / Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023 PID2023-150844OB-I00
,
AEI TED2021-129738B–I00
,
AEI RED2022-134120-T
,
MINECO CSIC13-4E-1794
DOI: http://hdl.handle.net/10261/381568, https://api.elsevier.com/content/abstract/scopus_id/85209367321
HANDLE: http://hdl.handle.net/10261/381568, https://api.elsevier.com/content/abstract/scopus_id/85209367321