Highest dominant frequency and rotor positions are robust markers of driver location during noninvasive mapping of atrial fibrillation: A computational study

  • RODRIGO BORT, MIGUEL
  • Liberos Mascarell, Alejandro
  • Fernandez-Aviles, Francisco
  • Berenfeld, Omer
  • Atienza, Felipe
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] BACKGROUND Dominant frequency (DF) and rotor mapping have been proposed as noninvasive techniques to guide localization of drivers maintaining atrial fibrillation (AF). OBJECTIVE The purpose of this study was to evaluate the robustness of both techniques in identifying atrial drivers noninvasively under the effect of electrical noise or model uncertainties. METHODS Inverse-computed DFs and phase maps were obtained from 30 different mathematical AF simulations. Epicardial highest dominant frequency (HDF) regions and rotor location were compared with the same inverse-computed measurements after addition of noise to the ECG, size variations of the atria, and linear or angular deviations in the atrial location inside the thorax. RESULTS Inverse-computed electrograms (EGMs) individually correlated poorly with the original EGMs in the absence of induced uncertainties (0.45 +/- 0.12) and were worse with 10-dB noise (0.22 +/- 0.11), 3-cm displacement (0.01 +/- 0.02), or 36 degrees rotation (0.02 +/- 0.03). However, inverse-computed HDF regions showed robustness against induced uncertainties: from 82% +/- 18% match for the best conditions, down to 73% +/- 23% for 10-dB noise, 77% +/- 21% for 5-cm displacement, and 60% +/- 22% for 36 degrees rotation. The distance from the inverse-computed rotor to the original rotor was also affected by uncertainties: 0.8 +/- 1.61 cm for the best conditions, 2.4 +/- 3.6 cm for 10-dB noise, 4.3 +/- 3.2 cm for 4-cm displacement, and 4.0 +/- 2.1 cm for 36 degrees rotation. Restriction of rotor detections to the HDF area increased rotor detection accuracy from 4.5 +/- 4.5 cm to 3.2 +/- 3.1 cm (P < .05) with 0-dB noise. CONCLUSION The combination of frequency and phase-derived measurements increases the accuracy of noninvasive localization of atrial rotors driving AF in the presence of noise and uncertainties in atrial location or size., This work was supported in part by grants from Generalitat Valenciana (ACIF/2013/021); Instituto de Salud Carlos III-FEDER (Fondo Europeo de Desarrollo Regional) and Ministerio de Ciencia e Innovacion (PI13-01882, PI13-00903, PI14/00857, PI16/01123, IJCI-2014-22178, DTS16/00160 and Red RIC RD12.0042.0001); Spanish Society of Cardiology (Clinical Research Grant 2015); and the National Heart, Lung, and Blood Institute (P01-HL039707, P01-HL087226, and Q1 R01-HL118304). Dr. Atienza served on the advisory board of Medtronic and Sorin. Dr. Berenfeld received research support from Medtronic and St. Jude Medical; and is a cofounder and Scientific Officer of Rhythm Solutions, Inc., Research and Development Director for S.A.S. Volta Medical, and consultant to Acutus Medical. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Presence and stability of rotors in atrial fibrillation: evidence and therapeutic implications

  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
  • Climent, Andreu M.
  • Rodrigo Bort, Miguel
  • Fernandez-Aviles, Francisco
  • Atienza, Felipe
  • Berenfeld, Omer
[EN] Rotor-guided ablation has opened new perspectives into the therapy of atrial fibrillation (AF). Analysis of the spatio-temporal cardiac excitation patterns in the frequency and phase domains has demonstrated the importance of rotors in research models of AF, however, the dynamics and role of rotors in human AF are still controversial. In this review, the current knowledge gained through research models and patient data that support the notion that rotors are key players in AF maintenance is summarized. We report and discuss discrepancies regarding rotor prevalence and stability in various studies, which can be attributed in part to methodological differences among mapping systems. Future research for validation and improvement of current clinical electrophysiology mapping technologies will be crucial for developing mechanistic-based selection and application of the best therapeutic strategy for individual AF patient, being it, pharmaceutical, ablative, or other approach., This work was supported in part by grants from the Instituto de Salud Carlos III (Ministry of Economy and Competitiveness, Spain: PI13-01882, PI13-00903, and PI14/00857), Spanish Society of Cardiology (Clinical Research Grant 2015), Generalitat Valenciana (ACIF/2013/021), Innovation (Red RIC, PLE2009-0152), and NHLBI (P01-HL039707, P01-HL087226, and R01-HL118304).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Ventricular Tachycardia and Early Fibrillation in Patients With Brugada Syndrome and Ischemic Cardiomyopathy Show Predictable Frequency-Phase Properties on the Precordial ECG Consistent With the Respective Arrhythmogenic Substrate

  • Calvo, David
  • Atienza, Felipe
  • Martinez, Laura
  • Ávila, Pablo
  • Rubín, José
  • Herreros, Benito
  • Arenal, Ángel
  • García-Fernández,Javier
  • Sebastian, Rafael
  • Martinez-Camblor, Pablo
  • Jalife, José
  • Berenfeld, Omer
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
  • FERRER ALBERO, ANA|||0000-0001-7642-916X
[EN] Background¿ Ventricular fibrillation (VF) has been proposed to be maintained by localized high-frequency sources. We tested whether spectral-phase analysis of the precordial ECG enabled identification of periodic activation patterns generated by such sources. Methods and Results¿Precordial ECGs were recorded from 15 ischemic cardiomyopathy and 15 Brugada syndrome (type 1 ECG) patients during induced VF and analyzed in the frequency-phase domain. Despite temporal variability, induced VF episodes lasting 19.6±7.9 s displayed distinctly high power at a common frequency (shared frequency, 5.7±1.1 Hz) in all leads about half of the time. In patients with Brugada syndrome, phase analysis of shared frequency showed a V1¿V6 sequence as would be expected from patients displaying a type 1 ECG pattern (P<0.001). Hilbert-based phases confirmed that the most stable sequence over the whole VF duration was V1¿V6. Analysis of shared frequency in ischemic cardiomyopathy patients with anteroseptal (n=4), apical (n=3), and inferolateral (n=4) myocardial infarction displayed a sequence starting at V1¿V2, V3¿V4, and V5¿V6, respectively, consistent with an activation origin at the scar location (P=0.005). Sequences correlated with the Hilbert-based phase analysis (P<0.001). Posterior infarction (n=4) displayed no specific sequence. On paired comparison, phase sequences during monomorphic ventricular tachycardia correlated moderately with VF (P<0.001). Moreover, there was a dominant frequency gradient from precordial leads facing the scar region to the contralateral leads (5.8±0.8 versus 5.4±1.1 Hz; P=0.004). Conclusions¿Noninvasive analysis of ventricular tachycardia and early VF in patients with Brugada syndrome and ischemic cardiomyopathy shows a predictable sequence in the frequency-phase domain, consistent with anatomic location of the arrhythmogenic substrate., This study was supported by the National Heart, Lung and Blood Institute (P01-HL039707, P01-HL087226 R01-HL118304); the Spanish Society of Cardiology, Arrhythmia and Electrophysiology Section; the Leducq Foundation, Paris, France; Centro Nacional de Investigaciones Cientificas, Madrid, Spain; Generalitat Valenciana, Valencia, Spain (PROMETEO/2012/030); VI Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica from the Ministerio de Economia y Competitividad of Spain (TIN2012-37546-C03-01); and the European Commission (European Regional Development Funds [ERDF]-FEDER)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Far-field contributions in multi-electrodes atrial recordings blur distinction between anatomical and functional reentries and may cause imaginary phase singularities A computational study

  • Martínez-Mateu, Laura
  • Berenfeld, Omer
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Background Atrial fibrillation (AF) is the most common cardiac arrhythmia and the most important cause of embolic stroke, requiring new technologies for its better understanding and therapies. Recent approaches to map the electrical activity during AF with multi-electrode systems aim at localizing patient-specific ablation targets of reentrant patterns. However, there is a critical need to determine the accuracy of those mapping systems. We performed computer simulations as a numerical approach of systematically evaluating the influence of far-field sources on the electrical recordings and detection of rotors. Methods We constructed 2 computer models of atrial tissue: (i) a 2D sheet model with varying non-active cells area in its center, and (ii) a whole realistic 3D atrial model. Phase maps were built based on the Hilbert transform of the unipolar electrograms recorded by virtual 2D and 3D multi-electrode systems and rotors were tracked through phase singularities detections. Results Analysis of electrograms recorded away from the 2D atrial model shows that the larger the distance between an electrode and the tissue model, the stronger the far-field sources contribution to the electrogram is. Importantly, even if an electrode is positioned in contact with the tissue, the electrogram contains significant contributions from distal sources that blur the distinction between anatomical and functional reentries. Moreover, when mapping the 3D atrial model, remote activity generated false phase singularities at locations without local reentrant excitation patterns. Conclusions Far-field contributions to electrograms during AF reduce the accuracy of detecting and interpreting reentrant activity., This work was supported in part by Programa Prometeu de la Conselleria d'Educacio, Formacio I Ocupacio de la Generalitat Valenciana, award number PROMETEU/2016/088; Plan Estatal de Investigacion Cientifica y Tecnica y de Innovacion 2013-2016 del Ministerio de Economia, Industria y Competitividad of Spain, Agencia Estatal de Investigacion and the European Commission (European Regional Development Funds - ERDF -FEDER), award number DPI2016-75799-R; The National Heart, Lung, and Blood Institute grant ROl-HL118304; the Gelman Award from the Cardiovascular Division at the University of Michigan; and the Coulter Program Award from the Dept. of Biomed Eng. at the University of Michigan.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Technical Considerations on Phase Mapping for Identification of Atrial Reentrant Activity in Direct- and Inverse-Computed Electrograms

  • RODRIGO BORT, MIGUEL
  • Liberos Mascarell, Alejandro
  • Fernández-Avilés, Francisco
  • Berenfeld, Omer
  • Atienza, Felipe
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] [Background] Phase mapping has become a broadly used technique to identify atrial reentrant circuits for ablative therapy guidance. This work studies the phase mapping process and how the signal nature and its filtering affect the reentrant pattern characterization in electrogram (EGM), body surface potential mapping, and electrocardiographic imaging signals. [Methods and Results] EGM, body surface potential mapping, and electrocardiographic imaging phase maps were obtained from 17 simulations of atrial fibrillation, atrial flutter, and focal atrial tachycardia. Reentrant activity was identified by singularity point recognition in raw signals and in signals after narrow band-pass filtering at the highest dominant frequency (HDF). Reentrant activity was dominantly present in the EGM recordings only for atrial fibrillation and some atrial flutter propagations patterns, and HDF filtering allowed increasing the reentrant activity detection from 60% to 70% of time in atrial fibrillation in unipolar recordings and from 0% to 62% in bipolar. In body surface potential mapping maps, HDF filtering increased from 10% to 90% the sensitivity, although provoked a residual false reentrant activity ¿30% of time. In electrocardiographic imaging, HDF filtering allowed to increase ¿100% the time with detected rotors, although provoked the apparition of false rotors during 100% of time. Nevertheless, raw electrocardiographic imaging phase maps presented reentrant activity just in atrial fibrillation recordings accounting for ¿80% of time. [Conclusions] Rotor identification is accurate and sensitive and does not require additional signal processing in measured or noninvasively computed unipolar EGMs. Bipolar EGMs and body surface potential mapping do require HDF filtering to detect rotors at the expense of a decreased specificity., This study was supported, in part, by Universitat Politecnica de Valencia through its research initiative program; Generalitat Valenciana Grants (ACIF/2013/021); the Instituto de Salud Carlos III (Ministry of Economy and Competitiveness, Spain: PI13-01882, PI13-00903, PI14/00857, PI16/01123, TEC2013-46067-R, DTS16/0160, and IJCI-2014-22178); Spanish Society of Cardiology (Grant for Clinical Research in Cardiology 2015); Spanish Ministry of Science and Innovation (Red RIC RD12.0042.0001); and the National Heart, Lung, and Blood Institute (P01-HL039707, P01-HL087226, and Q1 R01-HL118304) and cofounded by FEDER.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study

  • Martínez-Mateu, Laura
  • Sebastián Aguilar, Rafael
  • Rodriguez Matas, José Félix
  • Jalife, José
  • Berenfeld, Omer
  • Romero Pérez, Lucia|||0000-0003-4605-8630
  • FERRER ALBERO, ANA|||0000-0001-7642-916X
  • Saiz Rodríguez, Francisco Javier|||0000-0002-9850-0825
[EN] Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions within the atrial cavity. Unipolar electrograms were calculated on the entire endocardial surface and at each of the electrodes. Rotors were tracked on the interpolated basket phase maps and compared with the respective atrial voltage and endocardial phase maps, which served as references. Rotor detection by the basket maps varied between 35¿94% of the simulation time, depending on the basket¿s position and the electrode-to-endocardial wall distance. However, two different types of phantom rotors appeared also on the basket maps. The first type was due to the far-field sources and the second type was due to interpolation between the electrodes; increasing electrode density decreased the incidence of the second but not the first type of phantom rotors. In the simulations study, basket catheter-based phase mapping detected rotors even when the basket was not in full contact with the endocardial wall, but always generated a number of phantom rotors in the presence of only a single real rotor, which would be the desired ablation target. Phantom rotors may mislead and contribute to failure in AF ablation procedures., This work was partially supported by: Programa Prometeu de la Conselleria d'Educacio Formacio I Ocupacio, Generalitat Valenciana (www.edu.gva.es/fio/index_es.asp). Award Number: PROMETEU/2016/088 to JS;"Plan Estatal de Investigacion Cientifica y Tecnica y de Innovacion 2013-2016" from the Ministerio de Economia, Industria y Competitividad of Spain, Agencia Estatal de Investigacion (www.mineco.gob.es) and the European Commission (European Regional Development Funds - ERDF -FEDER) (ec.europa.eu/regional_policy/es/funding/erdf/) Award Number: DPI2016-75799-R to JS; "Programa Estatal de Investigacion, Desarrollo e Innovacion Orientado a los Retos de la Sociedad" from the Ministerio de Economia y Competitividad of Spain, Agencia Estatal de Investigacion (www.mineco.gob.es) and the European Commission (European Regional Development Funds - ERDF -FEDER) (ec.europa.eu/regional_policy/es/funding/erdf/) Award Number: TIN2014-59932-JIN to RS; National Institutes of Health (https://www.nih.gov/grants-funding). Award Numbers: R01-HL122352, P01-HL039707, P01-HL087236 and R01-HL118304 to OB; and research grant from Medtronic, Inc. (http://www.medtronic.com/us-en/about/foundation.html) to OB and JJ. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Electrocardiographic Imaging for Atrial Fibrillation: A Perspective From Computer Models and Animal Experiments to Clinical Value

  • Salinet, Joao
  • Molero-Alabau, Rubén
  • Schlindwein, Fernando S.
  • Karel, Joël
  • Rodrigo, Miguel
  • Rojo-Álvarez, José Luis
  • Berenfeld, Omer
  • Zenger, Brian
  • Vanheusden, Frederique
  • Siles Paredes, Jimena Gabriela
  • MacLeod, Rob
  • Atienza, Felipe
  • Cluitmans, Matthijs
  • Bonizzi, Pietro
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Electrocardiographic imaging (ECGI) is a technique to reconstruct non-invasively the electrical activity on the heart surface from body-surface potential recordings and geometric information of the torso and the heart. ECGI has shown scientific and clinical value when used to characterize and treat both atrial and ventricular arrhythmias. Regarding atrial fibrillation (AF), the characterization of the electrical propagation and the underlying substrate favoring AF is inherently more challenging than for ventricular arrhythmias, due to the progressive and heterogeneous nature of the disease and its manifestation, the small volume and wall thickness of the atria, and the relatively large role of microstructural abnormalities in AF. At the same time, ECGI has the advantage over other mapping technologies of allowing a global characterization of atrial electrical activity at every atrial beat and non-invasively. However, since ECGI is time-consuming and costly and the use of electrical mapping to guide AF ablation is still not fully established, the clinical value of ECGI for AF is still under assessment. Nonetheless, AF is known to be the manifestation of a complex interaction between electrical and structural abnormalities and therefore, true electro-anatomical-structural imaging may elucidate important key factors of AF development, progression, and treatment. Therefore, it is paramount to identify which clinical questions could be successfully addressed by ECGI when it comes to AF characterization and treatment, and which questions may be beyond its technical limitations. In this manuscript we review the questions that researchers have tried to address on the use of ECGI for AF characterization and treatment guidance (for example, localization of AF triggers and sustaining mechanisms), and we discuss the technological requirements and validation. We address experimental and clinical results, limitations, and future challenges for fruitful application of ECGI for AF understanding and management. We pay attention to existing techniques and clinical application, to computer models and (animal or human) experiments, to challenges of methodological and clinical validation. The overall objective of the study is to provide a consensus on valuable directions that ECGI research may take to provide future improvements in AF characterization and treatment guidance., JS was supported by Grants #2020/12841-3, #2020/13017-2, and #2018/25606-2, Sao Paulo Research Foundation (FAPESP). FS was supported by research grants from the Medical Research Council UK (MR/S037306/1), and from the British Heart Foundation (BHF Project Grant No. PG/18/33/33780). JR-A was supported by the projects (PID2019-106623RBC41) and meHeart (PID2019-104356RB-C42 and PID2019104356RB-C43) from the Spanish Government. JP was funded by Program of Alliances for Education and Training (Scholarship Brazil-PAEC OEA-GCUB-2017). RM, AC, and MG were supported by the Instituto de Salud Carlos III, and Ministerio de Ciencia, Innovacion y Universidades (supported by the FEDER Fondo Europeo de Desarrollo Regional PI17/01106 and RYC2018-024346B-750), EIT Health (Activity code 19600, EIT Health was supported by the EIT, a body of the European Union), received funding from the European Union's Horizon research and Innovation programme under the Marie Sklodowska-Curie grant agreement no. 860974 and the Generalitat Valenciana Grants (ACIF/2020/265). BZ and RM were supported by the NIH NHLBI Grant No. 1F30HL149327; NIH NIGMS Center for Integrative Biomedical Computing (www.sci.utah.edu/cibc), NIH NIGMS Grants P41GM103545 and R24 GM136986; and the Nora Eccles Treadwell Foundation for Cardiovascular Research. OB was supported in part by research grants from the National Institutes of Health (R01-HL118304 and R21-HL153694), Abbott, Medtronic, and CoreMap. MC was supported by a Veni Grant from the Netherlands Organization for Scientific Research (TTW 16772). FA was supported by the Instituto de Salud Carlos III (PI17/010559 and PI20/01618) and the Consorcio de Investigacion Biomedica en Red de Enfermedades Cardiovasculares (CIBERCV), the Ministerio de Ciencia e Innovacion (cofound by FEDER: Fondo Europeo de Desarrollo Regional), EIT Health (AFFINE 19600, EIT Health was supported by EIT, a body of the European Union).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Minimal configuration of body surface potential mapping for discrimination of left versus right dominant frequencies during atrial fibrillation

  • RODRIGO BORT, MIGUEL
  • Liberos Mascarell, Alejandro
  • Fernández-Avilés, Francisco
  • Atienza, Felipe
  • Berenfeld, Omer
  • Andreu M. Climent|||0000-0002-7260-8811
  • Guillem Sánchez, María Salud|||0000-0001-5660-3693
[EN] Background: Ablation of drivers maintaining atrial fibrillation (AF) has been demonstrated as an effective therapy. Drivers in the form of rapidly activated atrial regions can be noninvasively localized to either left or right atria (LA, RA) with body surface potential mapping (BSPM) systems. This study quantifies the accuracy of dominant frequency (DF) measurements from reduced-leads BSPM systems and assesses the minimal configuration required for ablation guidance. Methods: Nine uniformly distributed lead sets of eight to 66 electrodes were evaluated. BSPM signals were registered simultaneously with intracardiac electrocardiograms (EGMs) in 16 AF patients. DF activity was analyzed on the surface potentials for the nine leads configurations, and the noninvasive measures were compared with the EGM recordings. Results: Surface DF measurements presented similar values than panoramic invasive EGM recordings, showing the highest DF regions in corresponding locations. The noninvasive DFs measures had a high correlation with the invasive discrete recordings; they presented a deviation of <0.5 Hz for the highest DF and a correlation coefficient of >0.8 for leads configurations with 12 or more electrodes. Conclusions: Reduced-leads BSPM systems enable noninvasive discrimination between LA versus RA DFs with similar results as higher-resolution 66-leads system. Our findings demonstrate the possible incorporation of simplified BSPM systems into clinical planning procedures for AF ablation., This work was supported in part by Generalitat-Valenciana Grants [ACIF/2013/021]; Instituto de SaludCarlos III, Ministerio de Ciencia e Innovacion [PI13/00903, PI13-01882, PI14/00857, PI16/01123, TEC2013-46067-R, DTS16/0160 and IJCI-2014-22178] cofound by FEDER.; Spanish Society of Cardiology [Clinical research Grants 2015]; Ministerio de Ciencia e Innovacion [Red RICRD12.0042.0001]; and the National Heart, Lung, and Blood Institute [P01-HL039707, P01-HL087226 and R01-HL118304].