Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 11
Encontrada(s) 1 página(s)

eBiltegia. Repositorio Institucional de Mondragon Unibertsitatea
Publication Contribución de congreso (ConferenceOutput)

Dimensionamiento de Sistemas Fotovoltaicos con Almacenamiento Híbrido

eBiltegia. Repositorio Institucional de Mondragon Unibertsitatea
Publication Contribución de congreso (ConferenceOutput)

Análisis Experimental del Efecto de la Temperatura y la Tensión de Carga para la Optimización Energética de Sistemas de Almacenamiento de Instalaciones Fotovoltaicas Aisladas

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

New battery model considering thermal transport and partial charge stationary effects in photovoltaic off-grid applications

  • Sanz-Gorrachategui, Iván
  • Bernal, Carlos
  • Oyarbide, Estanis
  • Garayalde, Erik
  • Aizpuru, Iosu
  • Canales, Jose María
  • Bono-Nuez, Antonio
The optimization of the battery pack in an off-grid Photovoltaic application must consider the minimum sizing that assures the availability of the system under the worst environmental conditions. Thus, it is necessary to predict the evolution of the state of charge of the battery under incomplete daily charging and discharging processes and fluctuating temperatures over day-night cycles. Much of previous development work has been carried out in order to model the short term evolution of battery variables. Many works focus on the on-line parameter estimation of available charge, using standard or advanced estimators, but they are not focused on the development of a model with predictive capabilities. Moreover, normally stable environmental conditions and standard charge-discharge patterns are considered. As the actual cycle-patterns differ from the manufacturer's tests, batteries fail to perform as expected. This paper proposes a novel methodology to model these issues, with predictive capabilities to estimate the remaining charge in a battery after several solar cycles. A new non-linear state space model is proposed as a basis, and the methodology to feed and train the model is introduced. The new methodology is validated using experimental data, providing only 5% of error at higher temperatures than the nominal one.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Partial state-of-charge mitigation in standalone photovoltaic hybrid storage systems

  • Sanz Gorrachategui, Iván
  • Bernal Ruiz, Carlos
  • Oyarbide Usabiaga, Estanis
  • Bono Nuez, Antonio
  • Artal Sevil, Sergio Jesús
  • Garayalde Pérez, Érik
  • Aizpuru Larrañaga, Iosu
  • Canales Segade, Jose María
Energy Storage in photovoltaic installations has increased in popularity in recent years due to the improvement in solar panel technology and energy storage systems. In several places where the grid is not available, in remote isolated rural locations or developing countries, isolated photovoltaic installations are one of the main options to power DC micro-grids. In these scenarios, energy storage elements are mandatory due to the natural day-night cycles and low irradiation periods. Traditionally, lead-acid batteries have been responsible for this task, due to their availability and low cost. However, the intermittent features of the solar irradiance patterns and load demand, generate multiple shallow charge–discharge cycles or high power pulses, which worsen the performance of these batteries. Some Hybrid Energy Storage Systems (HESSs) have been reported in the literature to enhance the lifetime and power capabilities of these storage elements, but they are not intended to overcome the Partial State of Charge (PSoC) issue caused by daily cycles, which has an effect on the short and mid-term performance of the system. This paper studies the impact of the already proposed HESSs on PSoC operation, establishing the optimal hybrid ratios, and implementing them in a real installation with a satisfactory outcome.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Generalized discontinuous PWM strategy applied to a grid-connected modular multilevel converter

  • Artal-Sevil, J.S.
  • Bernal-Agustin, J.L.
  • Beyza, J.
  • Ruiz, H.F.
This paper presents a new PWM strategy for the control of active and reactive power flow, applied to a three-phase power inverter connected to a microgrid. Power quality and reactive compensation are essential in the integration of renewable energy sources in small grids (stand-alone mode or connected to the utility grid). The control algorithm of the grid-connected system is applied for voltage control. This technique provides independent control of the active and reactive power flow in the utility grid while maintaining constant the DC-link voltage. As a novelty, a Generalized Discontinuous PWM technique is implemented in the control algorithm of the grid-connected converter. Losses in the converter are reduced while the efficiency of the equipment is increased. As a technological innovation, in addition to the power flow control technique, a modular multilevel converter (MMC) is introduced. The main purpose of the system is to improve voltage unbalance and harmonic compensation in stand-alone grids. Some advantages of the model developed here include the cellular concept, easy thermal design, increased system efficiency and improvement in the system expansion capacity. The simulation model has been developed and tested using MATLAB/Simulink software.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Improved graph model for interdependent gas and electricity critical infrastructures

  • Beyza, J.
  • Ruiz, H.F.
  • Artal-Sevil, J.S.
  • Yusta, J.M.
Interdependence between gas and electricity transmission networks is a subject of concern due to the expanding use of gas for electricity generation in combined-cycle power plants around the world. This paper proposes a novel and much more accurate representation of natural gas and electrical networks based on graph theory, which includes all the assets of both systems and their couplings and offers a more realistic topological model of the two coupled networks. The representation is proposed as a scale-free graph and is mathematically validated in test networks, finding that the representations maintain the same characteristics of traditional graphs, but with more topological detail of the infrastructures.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Analysis of Li-ion battery degradation using self-organizing maps

  • Pastor-Flores, P.
  • Bernal-Ruiz, C.
  • Sanz-Gorrachategui, I.
  • Bono-Nuez, A.
  • Martin-Del-Brio, B.
  • Artal-Sevil, J.S.
  • Perez-Cebolla, F.J.
This paper proposes a new methodology to identify the different degradation processes of Li-Ion battery cells. The goal of this study is to determine if different degradation factors can be separated by waveform analysis from aged cells with similar remaining capacity. In contrast to other works, the proposed method identifies the past operating conditions in the cell, regardless of the actual State of Health. The methodology is based on a data-driven approach by using a SOM (Self-organizing map), an unsupervised neural network. To verify the hypothesis a SOM has been trained with laboratory data from whole data cycles, to classify cells concerning their degradation path and according to their discharge voltage patterns. Additionally, this new methodology based on the SOM allows discriminating groups of cells with different cycling conditions (based on depth of discharge, ambient temperature and discharge current). This research line is very promising for classification of used cells, not only depending on their current static parameters (capacity, impedance), but also the battery use in their past life. This will allow making predictions of the Remaining Useful Life (RUL) of a battery with greater precision.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Online voltage prediction using gaussian process regression for fault-tolerant photovoltaic standalone applications

  • Sanz Alcaine, José Miguel
  • Sebastián, Eduardo
  • Sanz-Gorrachategui, Iván
  • Bernal-Ruiz, Carlos
  • Bono-Nuez, Antonio
  • Pajovic, Milutin
  • Orlik, Philip V.
This paper presents a fault detection system for photovoltaic standalone applications based on Gaussian Process Regression (GPR). The installation is a communication repeater from the Confederacion Hidrografica del Ebro (CHE), public institution which manages the hydrographic system of Aragon, Spain. Therefore, fault-tolerance is a mandatory requirement, complex to fulfill since it depends on the meteorology, the state of the batteries and the power demand. To solve it, we propose an online voltage prediction solution where GPR is applied in a real and large dataset of two years to predict the behavior of the installation up to 48 hour. The dataset captures electrical and thermal measures of the lead-acid batteries which sustain the installation. In particular, the crucial aspect to avoid failures is to determine the voltage at the end of the night, so different GPR methods are studied. Firstly, the photovoltaic standalone installation is described, along with the dataset. Then, there is an overview of GPR, emphasizing in the key aspects to deal with real and large datasets. Besides, three online recursive multistep GPR model alternatives are tailored, justifying the selection of the hyperparameters: Regular GPR, Sparse GPR and Multiple Experts (ME) GPR. An exhaustive assessment is performed, validating the results with those obtained by Long Short-Term Memory (LSTM) and Nonlinear Autoregressive Exogenous Model (NARX) networks. A maximum error of 127 mV and 308 mV at the end of the night with Sparse and ME, respectively, corroborates GPR as a promising tool.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Evaluation of a Thermoelectric Generation system based on Differential-Power Processing architecture under non-uniform temperature conditions

  • Artal-Sevil, J.S.
  • Bernal-Ruiz, C.
  • Beyza, J.
  • Bravo, V.M.
This paper presents a Differential Power Processing (DPP) architecture applied to series-connected thermoelectric generators (TEG). Currently, thermoelectric technology is being considered as a promising power generation technology that can be used to recover waste heat energy. Thus, a thermoelectric generation system is studied under non-uniform temperature conditions in multiple TEG devices. The main objective is to allow each thermoelectric sub-module to reach its maximum power point more quickly. The purpose has been to improve the maximum power point tracking (MPPT) in each sub-module, thus it is possible to increase the efficiency with respect to the traditional method based on a global MPPT. Differential Power converters have been implemented in each TEG sub-module to provide an effective solution and mitigate the impact of the mismatch in the power obtained. The DPP architecture consists of a small micro-converter, at the submodular level, applied to the thermoelectric cell. The control algorithm is oriented to polarize each TEG device at its optimal point, which allows us an active balancing among the different TEG sub-modules regardless of the operating temperature. Matlab-Simulink has been the software used to develop the TEG module-Array.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Improving accuracy on wave height estimation through machine learning techniques

  • Gracia, S.
  • Olivito, J.
  • Resano, J.
  • Martin-del-Brio, B.
  • de Alfonso, M.
  • Álvarez, E.
Estimatabion of wave agitation plays a key role in predicting natural disasters, path optimization and secure harbor operation. The Spanish agency Puertos del Estado (PdE) has several oceanographic measure networks equipped with sensors for different physical variables, and manages forecast systems involving numerical models. In recent years, there is a growing interest in wave parameter estimation by using machine learning models due to the large amount of oceanographic data available for training, as well as its proven efficacy in estimating physical variables. In this study, we propose to use machine learning techniques to improve the accuracy of the current forecast system of PdE. We have focused on four physical wave variables: spectral significant height, mean spectral period, peak period and mean direction of origin. Two different machine learning models have been explored: multilayer perceptron and gradient boosting decision trees, as well as ensemble methods that combine both models. These models reduce the error of the predictions of the numerical model by 36% on average, demonstrating the potential gains of combining machine learning and numerical models.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Analysis and Implementation of different non-isolated Partial-Power Processing Architectures based on the Cuk Converter

  • Artal Sevil, Jesús Sergio
  • Anzola, Jon
  • Ballestín Bernad, Víctor
  • Bernal Agustín, José Luis
This paper presents the analysis and study of different partial-power processing architectures based on the Cuk converter. Thus, the non-isolated topologies analyzed have been considered operative as voltage source converter (VSC). Likewise, the study of the converters is based on the continuous conduction mode (CCM). The partial-power topology has some advantages, such as high power density, small size, the decreased voltage in semiconductor devices, etc., this is because the DC-DC converter only processes a fraction of the total power. The purpose has been to compare the different topologies, Full-Power, Partial-Power, and hybrid-converters, in order to observe the advantages and drawbacks in each case. Among the parameters to be studied is the voltage stress in semiconductors as well as the voltage gain in each architecture. The effectiveness of these new converter architectures has been validated by the Matlab/Simulink software simulation. In this way, different simulation results are presented and analyzed throughout the paper. The purpose of this paper has been to study and explore the usefulness of the non-isolated Cuk converter with partial-power processing architecture for industrial power applications.