Comparison of two radiofrequency-based hemostatic devices, saline-linked bipolar vs. cooled-electrode monopolar

  • Moll, Xavier|||0000-0002-2992-9361
  • Fondevila, Dolors|||0000-0001-7443-0175
  • García Arnas, Félix|||0000-0001-6651-3173
  • Burdío, Fernando|||0000-0003-3038-0086
  • Trujillo, Macarena
  • Irastorza, Ramiro M.
  • Berjano, Enrique|||0000-0002-3247-2665
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
Purpose: To characterize the coagulation zones created by two radiofrequency (RF)-based hemostatic devices: one comprised an internally cooled monopolar electrode and the other comprised externally irrigated bipolar electrodes (saline-linked). Materials and methods: RF-induced coagulation zones were created on ex vivo and in vivo porcine models. Computer modeling was used to determine the RF power distribution in the saline-linked device. Results: Both external (irrigation) and internal cooling effectively prevented tissue sticking. Under ex vivo conditions in 'painting' application mode, coagulation depth increased with the applied power: 2.8 - 5.6 mm with the 3-mm monopolar electrode, 1.6 - 6.0 mm with the 5-mm monopolar electrode and 0.6 - 3.2 mm with the saline-linked bipolar electrodes. Under in vivo conditions and using spot applications, the 3-mm monopolar electrode created coagulation zones of similar depth to the saline-linked bipolar electrodes (around 3 mm), while the 5-mm monopolar electrode created deeper coagulations (4.5 - 6 mm) with less incidence of popping. The presence of saline around the saline-linked bipolar electrodes meant that a significant percentage of RF power (50 - 80%) was dissipated by heating in the saline layer. Coagulation zones were histologically similar for all the tested devices. Conclusions: Both external (irrigation) and internal cooling in hemostatic RF devices effectively prevent tissue sticking and create similar coagulation zones from a histological point of view. Overall, saline-linked bipolar electrodes tend to create shallower coagulations than those created with an internally cooled monopolar electrode.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

The impact of additional margin coagulation with radiofrequency in liver resections with subcentimetric margin, can we improve the oncological results? A propensity score matching study

  • Villamonte, Maria
  • Burdío, Fernando|||0000-0003-3038-0086
  • Pueyo, Eva
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Moll, Xavier|||0000-0002-2992-9361
  • Berjano, Enrique|||0000-0002-3247-2665
  • Radosevic, Aleksander
  • Grande, L.|||0000-0001-9146-9004
  • Pera, Miguel|||0000-0001-7764-6481
  • Ielpo, Benedetto|||0000-0003-3129-3208
  • Sánchez Velázquez, Patricia|||0000-0002-7902-3920
Background: Whereas the usefulness of radiofrequency (RF) energy as haemostatic method in liver surgery has become well established in the last decades, its intentional application on resection margins with the aim of reducing local recurrence is still debatable. Our goal was to compare the impact of an additional application of RF energy on the top of the resection surface, namely additional margin coagulation (AMC), on local recurrence (LR) when subjected to a subcentimeter margin. Methods: We retrospectively analyzed 185 patients out of a whole cohort of 283 patients who underwent radical hepatic resection with subcentimetric margin. After propensity score adjustment, patients were classified into two balanced groups according to whether RF was applied or not. Results: No significant differences were observed within groups in baseline characteristics after PSM adjustment. The LR rate was significantly higher in the Control than AMC Group: 12 patients (14.5%) vs. 4 patients (4.8%) (p = 0.039). The estimated 1, 3, and 5-year LR-free survival rates of patients in the Control and AMC Group were: 93.5%, 86.0%, 81.0% and 98.8%, 97.2%, 91.9%, respectively (p = 0.049). Univariate Cox analyses indicated that the use of the RF applicator was significantly associated with lower LR (HR = 0.29, 95% confidence interval 0.093-0.906, p = 0.033). The Control Group showed smaller coagulation widths than the AMC group (p < 0.001). Conclusions: An additional application of RF on the top of the resection surface is associated with less local hepatic recurrence than the use of conventional techniques.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Is occlusion of the main pancreatic duct by thermal ablation really safe? A surgical innovation assessed according to IDEAL recommendations

  • Moll, Xavier|||0000-0002-2992-9361
  • Fondevila, Dolors|||0000-0001-7443-0175
  • García Arnas, Félix|||0000-0001-6651-3173
  • Pérez, Juan J.
  • Ielpo, Benedetto|||0000-0003-3129-3208
  • Sánchez Velázquez, Patricia|||0000-0002-7902-3920
  • Grande, L.|||0000-0001-9146-9004
  • Jaume, Sofía
  • Radosevic, Aleksandar
  • Barranco, Luis E.
  • Berjano, Enrique|||0000-0002-3247-2665
  • Burdío, Fernando|||0000-0003-3038-0086
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
Introduction: Pre-clinical studies suggest that thermal ablation of the main pancreatic duct (TAMPD) is more recommendable than glue for reducing postoperative pancreatic fistula (POPF). Our aims were (1) to analyze the changes in the pancreas of patients after TAMPD and (2) to correlate the clinical findings with those obtained from a study on an animal model. Materials and methods: A retrospective early feasibility study of a marketed device for a novel clinical application was carried out on a small number of subjects (n = 8) in whom TAMPD was conducted to manage the pancreatic stump after a pancreatectoduodenectomy (PD). Morphological changes in the remaining pancreas were assessed by computed tomography for 365 days after TAMPD. Results: All the patients showed either Grade A or B POPF, which generally resolved within the first 30 days. The duct's maximum diameter significantly increased after TAMPD from 1.5 ± 0.8 mm to 8.6 ± 2.9 mm after 7 days (p = .025) and was then reduced to 2.6 ± 0.8 mm after 365 days PO (p < .0001). The animal model suggests that TAMPD induces dilation of the duct lumen by enzymatic digestion of ablated tissue after a few days and complete exocrine atrophy after a few weeks. Conclusions: TAMPD leads to long-term exocrine pancreatic atrophy by completely occluding the duct. However, the ductal dilatation that occurred soon after TAMPD could even favor POPF, which suggests that TAMPD should be conducted several weeks before PD, ideally by digestive.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Preliminary evaluation of the safety and efficacy of glucose solution infusion through the hepatic artery on irreversible electroporation focusing

  • Sarreshtehdari, Amirhossein
  • Burdío Pinilla, Fernando
  • López Alonso, Borja
  • Lucía, Óscar
  • Burdío, José M.
  • Villamonte, Maria
  • Andaluz, Anna
  • García Arnas, Félix
  • Berjano, Enrique J.
  • Moll, Xavier
Due to electrical features of the tissue, such as impedance, which have a significant impact on irreversible electroporation (IRE) function, the administration of glucose solution 5% (GS5%) through the hepatic artery would focus IRE on scattered liver tumors. By creating a differential impedance between healthy and tumor tissue. This study aimed to determine the effects of the GS5% protocol on healthy liver tissue and its safety. 21 male Athymic nude rats Hsd: RH-Foxn1mu were used in the study. Animals were split into two groups. In group 1, a continuous infusion through the gastroduodenal artery of GS5% was performed to measure the impedance with a dose of 0.008 mL/g for 16 min. In group 2, the animals were divided into two subgroups for infusions of GS5%. Group 2.1, at 0.008 mL/g for 16 min. Group 2.2 at 0.03 mL/g for 4 min. Blood samples were collected after anesthesia has been induced. The second sample, after catheterization of the artery, and the third after the GS5% infusion. All the animals were sacrificed to collect histological samples. The survival rate during the experiment was 100%. A considerable impact on the impedance of the tissue was noticed, on average up to 4.31 times more than the baseline, and no side effects were observed after GS5% infusion. In conclusion, impedance alteration by Glucose solution infusion may focus IRE on tumor tissue and decrease IRE's effects on healthy tissue., This research was supported by the Spanish government (Ministry of Economy and Competitiveness) under Grants RTI2018-094357-B-C21, RTI2018-094357-B-C22 and Carlos III Health Institute under Grant PI17/0048 and also PI21/00440 from the same institution.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Development of a catheter-based technique for endoluminal radiofrequency sealing of pancreatic duct

  • Ewertowska, Elżbieta
  • Andaluz, Anna
  • Moll, Xavier
  • Aguilar, Adrià
  • Garcia, Felix
  • Fondevila, Dolors
  • Quesada Diez, Rita
  • Trujillo Guillén, Macarena
  • Burdío Pinilla, Fernando
  • Berjano, Enrique J.
introduction: Endoluminal sealing of the pancreatic duct by glue or sutures facilitates the management of the pancreatic stump. Our objective was to develop a catheter-based alternative for endoluminal radiofrequency (RF) sealing of the pancreatic duct. Materials and methods: We devised a novel RF ablation technique based on impedance-guided catheter pullback. First, bench tests were performed on ex vivo models to tune up the technique before the in vivo study, after which endoluminal RF sealing of a ∼10 cm non-transected pancreatic duct was conducted on porcine models using a 3 Fr catheter. After 30 days, sealing effectiveness was assessed by a permeability test and a histological analysis. Results: The RF technique was feasible in all cases and delivered ∼5 W of power on an initial impedance of 308 ± 60 Ω. Electrical impedance evolution was similar in all cases and provided guidance for modulating the pullback speed to avoid tissue sticking and achieve a continuous lesion. During the follow-up the animals rate of weight gain was significantly reduced (p < 0.05). Apart from signs of exocrine atrophy, no other postoperative complications were found. At necropsy, the permeability test failed and the catheter could not be reintroduced endoluminally, confirming that sealing had been successful. The histological analysis revealed a homogeneous exocrine atrophy along the ablated segment in all the animals. Conclusions: Catheter-based RF ablation could be used effectively and safely for endoluminal sealing of the pancreatic duct. The findings suggest that a fully continuous lesion may not be required to obtain complete exocrine atrophy., This work was supported by the Spanish Ministerio de Economía, Industria y Competitividad under “Plan Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” (Grant TEC2014–52383–C3–R) and by the Spanish Ministerio de Ciencia, Innovación y Universidades under “Programa Estatal de I + D + i Orientada a los Retos de la Sociedad" (Grant: RTI2018-094357-B-C21 and –C22). Elżbieta Ewertowska has a Predoctoral Grant (BES-2015–073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain). Also funding was received from Secretaría de Estado de Investigación, Desarrollo e Innovación.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Clinical case report: endoluminal thermal ablation of main pancreatic duct for patients at high risk of postoperative pancreatic fistula after pancreaticoduodenectomy

  • Ielpo, Benedetto
  • Pueyo Périz, Eva M.
  • Radosevic, Aleksandar, 1974-
  • Andaluz, Anna
  • Berjano, Enrique J.
  • Grande Posa, Luís
  • Sánchez Velázquez, Patricia, 1985-
  • Burdío Pinilla, Fernando
Purpose: Multiple attempts have been made to manage the pancreatic stump and the pancreatic duct in order to reduce the rate of postoperative pancreatic fistula (POPF) after pancreaticoduodenectomy (PD), however radiofrequency-based technologies could help to achieve this goal. Previous encouraging clinical and experimental results support the use of endoluminal thermal ablation (ETHA) of the main pancreatic duct to reduce pancreatic exocrine secretion and hence POPF. We here describe our initial clinical experience with ETHA of the main pancreatic duct in two cases at high risk of POPF. Methods: Two cases underwent PD for malignancy with a high risk of POPF (adenocarcinoma, obese patients, surgical difficulties with heavy intraoperative blood loss, soft pancreas or walled-off pancreatitis and a tight small pancreatic main duct). In both cases, ETHA of the main pancreatic duct was conducted intraoperatively just before Blumgart-type pancreatic-jejunal anastomosis using a ClosureFast catheter (Medtronic, Mansfield, MA, USA) normally used for varicose vein treatment (therefore an off-label use). Results: Although a clear radiological POPF was detected in the second case, the clinical postoperative course in both cases was uneventful. Little pancreatic fluid collected in the abdominal drainage with low levels of amylase enzyme, confirming low exocrine pancreatic function. No other procedure-related complications were detected. Conclusion: Endoluminal thermal ablation of the main pancreatic duct may be a feasible and safe technique to reduce the adverse effects of POPF after PD., This work was supported by the Spanish Ministerio de Ciencia, Innovación y Universidades under “Programa Estatal de I + D + i Orientada a los Retos de la Sociedad”, Grants RTI2018-094357-B-C21 and RTI2018-094357-B-C22.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Is occlusion of the main pancreatic duct by thermal ablation really safe? A surgical innovation assessed according to IDEAL recommendations

  • Moll, Xavier
  • Fondevila, Dolors
  • García Arnas, Félix
  • Pérez, Juan J.
  • Ielpo, Benedetto
  • Sánchez Velázquez, Patricia, 1985-
  • Grande Posa, Luís
  • Jaume, Sofía
  • Radosevic, Aleksandar, 1974-
  • Barranco Priego, Luis Eugenio
  • Berjano, Enrique J.
  • Burdío Pinilla, Fernando
  • Andaluz, Anna
Introduction: Pre-clinical studies suggest that thermal ablation of the main pancreatic duct (TAMPD) is more recommendable than glue for reducing postoperative pancreatic fistula (POPF). Our aims were (1) to analyze the changes in the pancreas of patients after TAMPD and (2) to correlate the clinical findings with those obtained from a study on an animal model. Materials and methods: A retrospective early feasibility study of a marketed device for a novel clinical application was carried out on a small number of subjects (n = 8) in whom TAMPD was conducted to manage the pancreatic stump after a pancreatectoduodenectomy (PD). Morphological changes in the remaining pancreas were assessed by computed tomography for 365 days after TAMPD. Results: All the patients showed either Grade A or B POPF, which generally resolved within the first 30 days. The duct's maximum diameter significantly increased after TAMPD from 1.5 ± 0.8 mm to 8.6 ± 2.9 mm after 7 days (p = .025) and was then reduced to 2.6 ± 0.8 mm after 365 days PO (p < .0001). The animal model suggests that TAMPD induces dilation of the duct lumen by enzymatic digestion of ablated tissue after a few days and complete exocrine atrophy after a few weeks. Conclusions: TAMPD leads to long-term exocrine pancreatic atrophy by completely occluding the duct. However, the ductal dilatation that occurred soon after TAMPD could even favor POPF, which suggests that TAMPD should be conducted several weeks before PD, ideally by digestive endoscopy., Spanish Ministerio de Ciencia, Innovación y Universidades/Agencia Estatal de Investigación (MCIN/AEI/10.13039/501100011033) under grants RTI2018-094357-B-C21 and RTI2018-094357-B-C22.
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

Comparison of two radiofrequency-based hemostatic devices: Saline-linked bipolar vs. cooled-electrode monopolar

  • Moll, Xavier
  • Fondevila, Dolors
  • García Arnas, Félix
  • Burdío Pinilla, Fernando
  • Trujillo Guillén, Macarena
  • Irastorza, Ramiro M.
  • Berjano, Enrique J.
  • Andaluz, Anna
Purpose: To characterize the coagulation zones created by two radiofrequency (RF)-based hemostatic devices: one comprised an internally cooled monopolar electrode and the other comprised externally irrigated bipolar electrodes (saline-linked). Materials and methods: RF-induced coagulation zones were created on ex vivo and in vivo porcine models. Computer modeling was used to determine the RF power distribution in the saline-linked device. Results: Both external (irrigation) and internal cooling effectively prevented tissue sticking. Under ex vivo conditions in 'painting' application mode, coagulation depth increased with the applied power: 2.8 - 5.6 mm with the 3-mm monopolar electrode, 1.6 - 6.0 mm with the 5-mm monopolar electrode and 0.6 - 3.2 mm with the saline-linked bipolar electrodes. Under in vivo conditions and using spot applications, the 3-mm monopolar electrode created coagulation zones of similar depth to the saline-linked bipolar electrodes (around 3 mm), while the 5-mm monopolar electrode created deeper coagulations (4.5 - 6 mm) with less incidence of popping. The presence of saline around the saline-linked bipolar electrodes meant that a significant percentage of RF power (50 - 80%) was dissipated by heating in the saline layer. Coagulation zones were histologically similar for all the tested devices. Conclusions: Both external (irrigation) and internal cooling in hemostatic RF devices effectively prevent tissue sticking and create similar coagulation zones from a histological point of view. Overall, saline-linked bipolar electrodes tend to create shallower coagulations than those created with an internally cooled monopolar electrode., Spanish Ministerio de Ciencia, Innovación y Universidades MCIN/AEI/10.13039/501100011033 [Grants RTI2018-094357-B-C21 and RTI2018-094357-B-C22], “Agencia Nacional de Promoción Científica y Tecnológica de Argentina” [PICT-2020-SERIEA-00457], Dr. Irastorza was the recipient of a scholarship from the Programa de Becas Externas Postdoctorales para Jóvenes Investigadores del CONICET (Argentina).
Repositorio Digital de la UPF
Publication Artículo científico (JournalArticle)

The impact of additional margin coagulation with radiofrequency in liver resections with subcentimetric margin: can we improve the oncological results? A propensity score matching study

  • Villamonte, Maria
  • Burdío Pinilla, Fernando
  • Pueyo Périz, Eva M.
  • Andaluz, Anna
  • Moll, Xavier
  • Berjano, Enrique J.
  • Radosevic, Aleksandar, 1974-
  • Grande Posa, Luís
  • Pera Román, Miguel
  • Ielpo, Benedetto
  • Sánchez Velázquez, Patricia, 1985-
Background: Whereas the usefulness of radiofrequency (RF) energy as haemostatic method in liver surgery has become well established in the last decades, its intentional application on resection margins with the aim of reducing local recurrence is still debatable. Our goal was to compare the impact of an additional application of RF energy on the top of the resection surface, namely additional margin coagulation (AMC), on local recurrence (LR) when subjected to a subcentimeter margin. Methods: We retrospectively analyzed 185 patients out of a whole cohort of 283 patients who underwent radical hepatic resection with subcentimetric margin. After propensity score adjustment, patients were classified into two balanced groups according to whether RF was applied or not. Results: No significant differences were observed within groups in baseline characteristics after PSM adjustment. The LR rate was significantly higher in the Control than AMC Group: 12 patients (14.5%) vs. 4 patients (4.8%) (p = 0.039). The estimated 1, 3, and 5-year LR-free survival rates of patients in the Control and AMC Group were: 93.5%, 86.0%, 81.0% and 98.8%, 97.2%, 91.9%, respectively (p = 0.049). Univariate Cox analyses indicated that the use of the RF applicator was significantly associated with lower LR (HR = 0.29, 95% confidence interval 0.093-0.906, p = 0.033). The Control Group showed smaller coagulation widths than the AMC group (p < 0.001). Conclusions: An additional application of RF on the top of the resection surface is associated with less local hepatic recurrence than the use of conventional techniques., This work was partially supported by the Spanish Ministerio de Ciencia, Innovación y Universidades under “Programa Estatal de I+D+i Orientada a los Retos de la Sociedad”, Grants Nº “ RTI2018-094357-B-C21 ” and “ RTI2018-094357-B-C22”.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Development of a catheter-based technique for endoluminal radiofrequency sealing of pancreatic duct

  • Ewertowska, Elzbieta
  • Andaluz, Anna
  • Moll, Xavier
  • Adrià Aguilar
  • Garcia, Felix
  • Fondevila, Dolors
  • Quesada, Rita
  • Burdio, Fernando
  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Introduction: Endoluminal sealing of the pancreatic duct by glue or sutures facilitates the management of the pancreatic stump. Our objective was to develop a catheter-based alternative for endoluminal radiofrequency (RF) sealing of the pancreatic duct. Materials and methods: We devised a novel RF ablation technique based on impedance-guided catheter pullback. First, bench tests were performed on ex vivo models to tune up the technique before the in vivo study, after which endoluminal RF sealing of a similar to 10 cm non-transected pancreatic duct was conducted on porcine models using a 3 Fr catheter. After 30 days, sealing effectiveness was assessed by a permeability test and a histological analysis. Results: The RF technique was feasible in all cases and delivered similar to 5 W of power on an initial impedance of 308 +/- 60 ohm. Electrical impedance evolution was similar in all cases and provided guidance for modulating the pullback speed to avoid tissue sticking and achieve a continuous lesion. During the follow-up the animals rate of weight gain was significantly reduced (p < 0.05). Apart from signs of exocrine atrophy, no other postoperative complications were found. At necropsy, the permeability test failed and the catheter could not be reintroduced endoluminally, confirming that sealing had been successful. The histological analysis revealed a homogeneous exocrine atrophy along the ablated segment in all the animals. Conclusions: Catheter-based RF ablation could be used effectively and safely for endoluminal sealing of the pancreatic duct. The findings suggest that a fully continuous lesion may not be required to obtain complete exocrine atrophy., This work was supported by the Spanish Ministerio de Economia, Industria y Competitividad under "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad" (Grant TEC2014-52383-C3-R) and by the Spanish Ministerio de Ciencia, Innovacion y Universidades under "Programa Estatal de I+D+i Orientada a los Retos de la Sociedad" (Grant: RTI2018-094357-B-C21 and -C22). Elzbieta Ewertowska has a Predoctoral Grant (BES-2015-073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain). Also funding was received from Secretaria de Estado de Investigacion, Desarrollo e Innovacion.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Clinical case report: endoluminal thermal ablation of main pancreatic duct for patients at high risk of postoperative pancreatic fistula after pancreaticoduodenectomy

  • Ielpo, Benedetto
  • Pueyo-Périz, Eva M.
  • Radosevic, Aleksandar
  • Andaluz, Anna
  • Grande, Luis
  • Sánchez-Velázquez, Patricia
  • Burdío, Fernando
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Purpose Multiple attempts have been made to manage the pancreatic stump and the pancreatic duct in order to reduce the rate of postoperative pancreatic fistula (POPF) after pancreaticoduodenectomy (PD), however radiofrequency-based technologies could help to achieve this goal. Previous encouraging clinical and experimental results support the use of endoluminal thermal ablation (ETHA) of the main pancreatic duct to reduce pancreatic exocrine secretion and hence POPF. We here describe our initial clinical experience with ETHA of the main pancreatic duct in two cases at high risk of POPF. Methods Two cases underwent PD for malignancy with a high risk of POPF (adenocarcinoma, obese patients, surgical difficulties with heavy intraoperative blood loss, soft pancreas or walled-off pancreatitis and a tight small pancreatic main duct). In both cases, ETHA of the main pancreatic duct was conducted intraoperatively just before Blumgart-type pancreatic-jejunal anastomosis using a ClosureFast catheter (Medtronic, Mansfield, MA, USA) normally used for varicose vein treatment (therefore an off-label use). Results Although a clear radiological POPF was detected in the second case, the clinical postoperative course in both cases was uneventful. Little pancreatic fluid collected in the abdominal drainage with low levels of amylase enzyme, confirming low exocrine pancreatic function. No other procedure-related complications were detected. Conclusion Endoluminal thermal ablation of the main pancreatic duct may be a feasible and safe technique to reduce the adverse effects of POPF after PD., This work was supported by the Spanish Ministerio de Ciencia, Innovacion y Universidades under "Programa Estatal de IthornDthorni Orientada a los Retos de la Sociedad", Grants RTI2018-094357-B-C21 and RTI2018-094357-B-C22.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Pancreatic duct ligation reduces premalignant pancreatic lesions in a Kras model of pancreatic adenocarcinoma in mice

  • Cáceres, Marta
  • Quesada, Rita
  • Iglesias, Mar
  • Real, Francisco X.
  • Villamonte, Maria
  • Martinez de Villarreal, Jaime
  • Pérez, Mónica
  • Andaluz, Ana
  • Moll, Xavier
  • Dorcaratto, Dimitri
  • Sánchez Velazquez, Patricia
  • Grande, Luis
  • Burdío, Fernando
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Pancreatic duct ligation (PDL) in the murine model has been described as an exocrine pancreatic atrophy-inducing procedure. However, its influence has scarcely been described on premalignant lesions. This study describes the histological changes of premalignant lesions and the gene expression in a well-defined model of pancreatic ductal adenocarcinoma by PDL. Selective ligation of the splenic lobe of the pancreas was performed in Ptf1a-Cre((+/ki)); K-ras LSLG12Vgeo((+/ki)) mice (PDL-Kras mice). Three experimental groups were evaluated: PDL group, controls and shams. The presence and number of premalignant lesions (PanIN 1-3 and Atypical Flat Lesions-AFL) in proximal (PP) and distal (DP) pancreas were studied for each group over time. Microarray analysis was performed to find differentially expressed genes (DEG) between PP and PD. Clinical human specimens after pancreaticoduodenectomy with ductal occlusion were also evaluated. PDL-Kras mice showed an intense pattern of atrophy in DP which was shrunk to a minimal portion of tissue. Mice in control and sham groups had a 7 and 10-time increase respectively of risk of high-grade PanIN 2 and 3 and AFL in their DP than PDL-Kras mice. Furthermore, PDL-Kras mice had significantly less PanIN 1 and 2 and AFL lesions in DP compared to PP. We identified 38 DEGs comparing PP and PD. Among them, several mapped to protein secretion and digestion while others such as Nupr1 have been previously associated with PanIN and PDAC. PDL in Ptf1a-Cre((+/ki)); K-ras LSLG12Vgeo((+/ki)) mice induces a decrease in the presence of premalignant lesions in the ligated DP. This could be a potential line of research of interest in some cancerous risk patients., This work was supported by the Spanish Ministerio de Economia, Industria y Competitividad under "Plan Estatal de Investigacion, Desarrollo e Innovacion Orientada a los Retos de la Sociedad", Grant No "RTI2018-094357-B-C22".
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

The impact of additional margin coagulation with radiofrequency in liver resections with subcentimetric margin: can we improve the oncological results? A propensity score matching study

  • Villamonte, Maria
  • Burdio, Fernando
  • Pueyo, Eva
  • Andaluz, Ana
  • Moll, Xavier
  • Radosevic, Aleksander
  • Grande, Luis
  • Pera, Miguel
  • Ielpo, Benedetto
  • Sánchez-Velázquez, Patricia
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Background Whereas the usefulness of radiofrequency (RF) energy as haemostatic method in liver surgery has become well established in the last decades, its intentional application on resection margins with the aim of reducing local recurrence is still debatable. Our goal was to compare the impact of an additional application of RF energy on the top of the resection surface, namely additional margin coagulation (AMC), on local recurrence (LR) when subjected to a subcentimeter margin. Methods We retrospectively analyzed 185 patients out of a whole cohort of 283 patients who underwent radical hepatic resection with subcentimetric margin. After propensity score adjustment, patients were classified into two balanced groups according to whether RF was applied or not. Results No significant differences were observed within groups in baseline characteristics after PSM adjustment. The LR rate was significantly higher in the Control than AMC Group: 12 patients (14.5%) vs. 4 patients (4.8%) (p = 0.039). The estimated 1, 3, and 5-year LR-free survival rates of patients in the Control and AMC Group were: 93.5%, 86.0%, 81.0% and 98.8%, 97.2%, 91.9%, respectively (p = 0.049). Univariate Cox analyses indicated that the use of the RF applicator was significantly associated with lower LR (HR = 0.29, 95% confidence interval 0.093¿0.906, p = 0.033). The Control Group showed smaller coagulation widths than the AMC group (p < 0.001). Conclusions An additional application of RF on the top of the resection surface is associated with less local hepatic recurrence than the use of conventional techniques., This work was partially supported by the Spanish Ministerio de Ciencia, Innovación y Universidades under "Programa Estatal de I+D+i Orientada a los Retos de la Sociedad", Grants Nº "RTI2018-094357-B-C21" and "RTI2018-094357-B-C22"
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Comparison of two radiofrequency-based hemostatic devices: saline-linked bipolar vs. cooled-electrode monopolar

  • Moll, Xavier
  • Fondevila, Dolors
  • García-Arnás, Félix
  • Burdio, Fernando
  • Irastorza, Ramiro M.
  • Andaluz, Anna
  • Trujillo Guillen, Macarena|||0000-0003-4145-2188
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Purpose To characterize the coagulation zones created by two radiofrequency (RF)-based hemostatic devices: one comprised an internally cooled monopolar electrode and the other comprised externally irrigated bipolar electrodes (saline-linked). Materials and methods RF-induced coagulation zones were created on ex vivo and in vivo porcine models. Computer modeling was used to determine the RF power distribution in the saline-linked device. Results Both external (irrigation) and internal cooling effectively prevented tissue sticking. Under ex vivo conditions in 'painting' application mode, coagulation depth increased with the applied power: 2.8 - 5.6 mm with the 3-mm monopolar electrode, 1.6 - 6.0 mm with the 5-mm monopolar electrode and 0.6 - 3.2 mm with the saline-linked bipolar electrodes. Under in vivo conditions and using spot applications, the 3-mm monopolar electrode created coagulation zones of similar depth to the saline-linked bipolar electrodes (around 3 mm), while the 5-mm monopolar electrode created deeper coagulations (4.5 - 6 mm) with less incidence of popping. The presence of saline around the saline-linked bipolar electrodes meant that a significant percentage of RF power (50 - 80%) was dissipated by heating in the saline layer. Coagulation zones were histologically similar for all the tested devices. Conclusions Both external (irrigation) and internal cooling in hemostatic RF devices effectively prevent tissue sticking and create similar coagulation zones from a histological point of view. Overall, saline-linked bipolar electrodes tend to create shallower coagulations than those created with an internally cooled monopolar electrode., Spanish Ministerio de Ciencia, Innovacion y Universidades MCIN/AEI/10.13039/501100011033 [Grants RTI2018-094357-B-C21 and RTI2018094357-B-C22], "Agencia Nacional de Promocion Cientifica y Tecnologica de Argentina" [PICT-2020-SERIEA-00457], Dr. Irastorza was the recipient of a scholarship from the Programa de Becas Externas Postdoctorales para Jovenes Investigadores del CONICET (Argentina).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Is occlusion of the main pancreatic duct by thermal ablation really safe? A surgical innovation assessed according to IDEAL recommendations

  • Moll, Xavier
  • Fondevila, Dolors
  • García Arnás, Felix
  • Ielpo, Benedetto
  • Sánchez-Velázquez, Patricia
  • Grande, Luis
  • Jaume, Sofia
  • Radosevic, Aleksandar
  • Barranco, Luis
  • Burdio, Fernando
  • Andaluz, Anna
  • Pérez, Juan J|||0000-0001-8486-8699
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Introduction Pre-clinical studies suggest that thermal ablation of the main pancreatic duct (TAMPD) is more recommendable than glue for reducing postoperative pancreatic fistula (POPF). Our aims were (1) to analyze the changes in the pancreas of patients after TAMPD and (2) to correlate the clinical findings with those obtained from a study on an animal model. Materials and methods A retrospective early feasibility study of a marketed device for a novel clinical application was carried out on a small number of subjects (n = 8) in whom TAMPD was conducted to manage the pancreatic stump after a pancreatectoduodenectomy (PD). Morphological changes in the remaining pancreas were assessed by computed tomography for 365 days after TAMPD. Results All the patients showed either Grade A or B POPF, which generally resolved within the first 30 days. The duct's maximum diameter significantly increased after TAMPD from 1.5 +/- 0.8 mm to 8.6 +/- 2.9 mm after 7 days (p = .025) and was then reduced to 2.6 +/- 0.8 mm after 365 days PO (p < .0001). The animal model suggests that TAMPD induces dilation of the duct lumen by enzymatic digestion of ablated tissue after a few days and complete exocrine atrophy after a few weeks. Conclusions TAMPD leads to long-term exocrine pancreatic atrophy by completely occluding the duct. However, the ductal dilatation that occurred soon after TAMPD could even favor POPF, which suggests that TAMPD should be conducted several weeks before PD, ideally by digestive endoscopy., Spanish Ministerio de Ciencia, Innovación y Universidades/AgenciaEstatal de Investigación (MCIN/AEI/10.13039/501100011033) under grants RTI2018-094357-B-C21 and RTI2018-094357-B-C22.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Preliminary evaluation of the safety and efficacy of glucose solution infusion through the hepatic artery on irreversible electroporation focusing.

  • Sarreshtehdari, Amirhossein
  • Burdio, Fernando
  • López-Alonso, Borja
  • Lucia, Oscar
  • Burdio, José Miguel
  • Villamonte, Maria
  • Andaluz, A.
  • García-Arnás, F.
  • Moll, Xavier
  • Berjano, Enrique|||0000-0002-3247-2665
[EN] Due to electrical features of the tissue, such as impedance, which have a significant impact on irreversible electroporation (IRE) function, the administration of glucose solution 5% (GS5%) through the hepatic artery would focus IRE on scattered liver tumors. By creating a differential impedance between healthy and tumor tissue. This study aimed to determine the effects of the GS5% protocol on healthy liver tissue and its safety. 21 male Athymic nude rats Hsd: RH-Foxn1mu were used in the study. Animals were split into two groups. In group 1, a continuous infusion through the gastroduodenal artery of GS5% was performed to measure the impedance with a dose of 0.008 mL/g for 16 min. In group 2, the animals were divided into two subgroups for infusions of GS5%. Group 2.1, at 0.008 mL/g for 16 min. Group 2.2 at 0.03 mL/g for 4 min. Blood samples were collected after anesthesia has been induced. The second sample, after catheterization of the artery, and the third after the GS5% infusion. All the animals were sacrificed to collect histological samples. The survival rate during the experiment was 100%. A considerable impact on the impedance of the tissue was noticed, on average up to 4.31 times more than the baseline, and no side effects were observed after GS5% infusion. In conclusion, impedance alteration by Glucose solution infusion may focus IRE on tumor tissue and decrease IRE¿s effects on healthy tissue., This research was supported by the Spanish government (Ministry of Economy and Competitiveness) under Grants RTI2018-094357-B-C21, RTI2018-094357-B-C22 and Carlos III Health Institute under Grant PI17/0048 and also PI21/00440 from the same institution.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Preliminary evaluation of the safety and efficacy of glucose solution infusion through the hepatic artery on irreversible electroporation focusing

  • Sarreshtehdari, Amirhossein
  • Burdio, Fernando
  • López-Alonso, Borja
  • Lucía, Óscar
  • Burdio, José Miguel
  • Villamonte, María
  • Andaluz, A.
  • García-Arnas, F.
  • Berjano, E.
  • Moll, Xavier
Due to electrical features of the tissue, such as impedance, which have a significant impact on irreversible electroporation (IRE) function, the administration of glucose solution 5% (GS5%) through the hepatic artery would focus IRE on scattered liver tumors. By creating a differential impedance between healthy and tumor tissue. This study aimed to determine the effects of the GS5% protocol on healthy liver tissue and its safety. 21 male Athymic nude rats Hsd: RH-Foxn1mu were used in the study. Animals were split into two groups. In group 1, a continuous infusion through the gastroduodenal artery of GS5% was performed to measure the impedance with a dose of 0.008 mL/g for 16 min. In group 2, the animals were divided into two subgroups for infusions of GS5%. Group 2.1, at 0.008 mL/g for 16 min. Group 2.2 at 0.03 mL/g for 4 min. Blood samples were collected after anesthesia has been induced. The second sample, after catheterization of the artery, and the third after the GS5% infusion. All the animals were sacrificed to collect histological samples. The survival rate during the experiment was 100%. A considerable impact on the impedance of the tissue was noticed, on average up to 4.31 times more than the baseline, and no side effects were observed after GS5% infusion. In conclusion, impedance alteration by Glucose solution infusion may focus IRE on tumor tissue and decrease IRE’s effects on healthy tissue.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Comparison of two radiofrequency-based hemostatic devices: Saline-linked bipolar vs. cooled-electrode monopolar

  • Moll, Xavier
  • Fondevila, Dolors
  • García Arnas, Félix
  • Burdío Pinilla, Fernando
  • Trujillo Guillén, Macarena
  • Irastorza, Ramiro M.
  • Berjano, Enrique J.
  • Andaluz, Anna
Purpose: To characterize the coagulation zones created by two radiofrequency (RF)-based hemostatic devices: one comprised an internally cooled monopolar electrode and the other comprised externally irrigated bipolar electrodes (saline-linked). Materials and methods: RF-induced coagulation zones were created on ex vivo and in vivo porcine models. Computer modeling was used to determine the RF power distribution in the saline-linked device. Results: Both external (irrigation) and internal cooling effectively prevented tissue sticking. Under ex vivo conditions in 'painting' application mode, coagulation depth increased with the applied power: 2.8 - 5.6 mm with the 3-mm monopolar electrode, 1.6 - 6.0 mm with the 5-mm monopolar electrode and 0.6 - 3.2 mm with the saline-linked bipolar electrodes. Under in vivo conditions and using spot applications, the 3-mm monopolar electrode created coagulation zones of similar depth to the saline-linked bipolar electrodes (around 3 mm), while the 5-mm monopolar electrode created deeper coagulations (4.5 - 6 mm) with less incidence of popping. The presence of saline around the saline-linked bipolar electrodes meant that a significant percentage of RF power (50 - 80%) was dissipated by heating in the saline layer. Coagulation zones were histologically similar for all the tested devices. Conclusions: Both external (irrigation) and internal cooling in hemostatic RF devices effectively prevent tissue sticking and create similar coagulation zones from a histological point of view. Overall, saline-linked bipolar electrodes tend to create shallower coagulations than those created with an internally cooled monopolar electrode., Spanish Ministerio de Ciencia, Innovación y Universidades MCIN/AEI/10.13039/501100011033 [Grants RTI2018-094357-B-C21 and RTI2018-094357-B-C22], “Agencia Nacional de Promoción Científica y Tecnológica de Argentina” [PICT-2020-SERIEA-00457], Dr. Irastorza was the recipient of a scholarship from the Programa de Becas Externas Postdoctorales para Jóvenes Investigadores del CONICET (Argentina).
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

The impact of additional margin coagulation with radiofrequency in liver resections with subcentimetric margin: can we improve the oncological results? A propensity score matching study

  • Villamonte, Maria
  • Burdío Pinilla, Fernando
  • Pueyo Périz, Eva M.
  • Andaluz, Anna
  • Moll, Xavier
  • Berjano, Enrique J.
  • Radosevic, Aleksandar, 1974-
  • Grande Posa, Luís
  • Pera Román, Miguel
  • Ielpo, Benedetto
  • Sánchez Velázquez, Patricia, 1985-
Background: Whereas the usefulness of radiofrequency (RF) energy as haemostatic method in liver surgery has become well established in the last decades, its intentional application on resection margins with the aim of reducing local recurrence is still debatable. Our goal was to compare the impact of an additional application of RF energy on the top of the resection surface, namely additional margin coagulation (AMC), on local recurrence (LR) when subjected to a subcentimeter margin. Methods: We retrospectively analyzed 185 patients out of a whole cohort of 283 patients who underwent radical hepatic resection with subcentimetric margin. After propensity score adjustment, patients were classified into two balanced groups according to whether RF was applied or not. Results: No significant differences were observed within groups in baseline characteristics after PSM adjustment. The LR rate was significantly higher in the Control than AMC Group: 12 patients (14.5%) vs. 4 patients (4.8%) (p = 0.039). The estimated 1, 3, and 5-year LR-free survival rates of patients in the Control and AMC Group were: 93.5%, 86.0%, 81.0% and 98.8%, 97.2%, 91.9%, respectively (p = 0.049). Univariate Cox analyses indicated that the use of the RF applicator was significantly associated with lower LR (HR = 0.29, 95% confidence interval 0.093-0.906, p = 0.033). The Control Group showed smaller coagulation widths than the AMC group (p < 0.001). Conclusions: An additional application of RF on the top of the resection surface is associated with less local hepatic recurrence than the use of conventional techniques., This work was partially supported by the Spanish Ministerio de Ciencia, Innovación y Universidades under “Programa Estatal de I+D+i Orientada a los Retos de la Sociedad”, Grants Nº “ RTI2018-094357-B-C21 ” and “ RTI2018-094357-B-C22”.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Clinical case report: endoluminal thermal ablation of main pancreatic duct for patients at high risk of postoperative pancreatic fistula after pancreaticoduodenectomy

  • Ielpo, Benedetto
  • Pueyo Périz, Eva M.
  • Radosevic, Aleksandar, 1974-
  • Andaluz, Anna
  • Berjano, Enrique J.
  • Grande Posa, Luís
  • Sánchez Velázquez, Patricia, 1985-
  • Burdío Pinilla, Fernando
Purpose: Multiple attempts have been made to manage the pancreatic stump and the pancreatic duct in order to reduce the rate of postoperative pancreatic fistula (POPF) after pancreaticoduodenectomy (PD), however radiofrequency-based technologies could help to achieve this goal. Previous encouraging clinical and experimental results support the use of endoluminal thermal ablation (ETHA) of the main pancreatic duct to reduce pancreatic exocrine secretion and hence POPF. We here describe our initial clinical experience with ETHA of the main pancreatic duct in two cases at high risk of POPF. Methods: Two cases underwent PD for malignancy with a high risk of POPF (adenocarcinoma, obese patients, surgical difficulties with heavy intraoperative blood loss, soft pancreas or walled-off pancreatitis and a tight small pancreatic main duct). In both cases, ETHA of the main pancreatic duct was conducted intraoperatively just before Blumgart-type pancreatic-jejunal anastomosis using a ClosureFast catheter (Medtronic, Mansfield, MA, USA) normally used for varicose vein treatment (therefore an off-label use). Results: Although a clear radiological POPF was detected in the second case, the clinical postoperative course in both cases was uneventful. Little pancreatic fluid collected in the abdominal drainage with low levels of amylase enzyme, confirming low exocrine pancreatic function. No other procedure-related complications were detected. Conclusion: Endoluminal thermal ablation of the main pancreatic duct may be a feasible and safe technique to reduce the adverse effects of POPF after PD., This work was supported by the Spanish Ministerio de Ciencia, Innovación y Universidades under “Programa Estatal de I + D + i Orientada a los Retos de la Sociedad”, Grants RTI2018-094357-B-C21 and RTI2018-094357-B-C22.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Is occlusion of the main pancreatic duct by thermal ablation really safe? A surgical innovation assessed according to IDEAL recommendations

  • Moll, Xavier
  • Fondevila, Dolors
  • García Arnas, Félix
  • Pérez, Juan J.
  • Ielpo, Benedetto
  • Sánchez Velázquez, Patricia, 1985-
  • Grande Posa, Luís
  • Jaume, Sofía
  • Radosevic, Aleksandar, 1974-
  • Barranco Priego, Luis Eugenio
  • Berjano, Enrique J.
  • Burdío Pinilla, Fernando
  • Andaluz, Anna
Introduction: Pre-clinical studies suggest that thermal ablation of the main pancreatic duct (TAMPD) is more recommendable than glue for reducing postoperative pancreatic fistula (POPF). Our aims were (1) to analyze the changes in the pancreas of patients after TAMPD and (2) to correlate the clinical findings with those obtained from a study on an animal model. Materials and methods: A retrospective early feasibility study of a marketed device for a novel clinical application was carried out on a small number of subjects (n = 8) in whom TAMPD was conducted to manage the pancreatic stump after a pancreatectoduodenectomy (PD). Morphological changes in the remaining pancreas were assessed by computed tomography for 365 days after TAMPD. Results: All the patients showed either Grade A or B POPF, which generally resolved within the first 30 days. The duct's maximum diameter significantly increased after TAMPD from 1.5 ± 0.8 mm to 8.6 ± 2.9 mm after 7 days (p = .025) and was then reduced to 2.6 ± 0.8 mm after 365 days PO (p < .0001). The animal model suggests that TAMPD induces dilation of the duct lumen by enzymatic digestion of ablated tissue after a few days and complete exocrine atrophy after a few weeks. Conclusions: TAMPD leads to long-term exocrine pancreatic atrophy by completely occluding the duct. However, the ductal dilatation that occurred soon after TAMPD could even favor POPF, which suggests that TAMPD should be conducted several weeks before PD, ideally by digestive endoscopy., Spanish Ministerio de Ciencia, Innovación y Universidades/Agencia Estatal de Investigación (MCIN/AEI/10.13039/501100011033) under grants RTI2018-094357-B-C21 and RTI2018-094357-B-C22.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Preliminary evaluation of the safety and efficacy of glucose solution infusion through the hepatic artery on irreversible electroporation focusing

  • Sarreshtehdari, Amirhossein
  • Burdío Pinilla, Fernando
  • López Alonso, Borja
  • Lucía, Óscar
  • Burdío, José M.
  • Villamonte, Maria
  • Andaluz, Anna
  • García Arnas, Félix
  • Berjano, Enrique J.
  • Moll, Xavier
Due to electrical features of the tissue, such as impedance, which have a significant impact on irreversible electroporation (IRE) function, the administration of glucose solution 5% (GS5%) through the hepatic artery would focus IRE on scattered liver tumors. By creating a differential impedance between healthy and tumor tissue. This study aimed to determine the effects of the GS5% protocol on healthy liver tissue and its safety. 21 male Athymic nude rats Hsd: RH-Foxn1mu were used in the study. Animals were split into two groups. In group 1, a continuous infusion through the gastroduodenal artery of GS5% was performed to measure the impedance with a dose of 0.008 mL/g for 16 min. In group 2, the animals were divided into two subgroups for infusions of GS5%. Group 2.1, at 0.008 mL/g for 16 min. Group 2.2 at 0.03 mL/g for 4 min. Blood samples were collected after anesthesia has been induced. The second sample, after catheterization of the artery, and the third after the GS5% infusion. All the animals were sacrificed to collect histological samples. The survival rate during the experiment was 100%. A considerable impact on the impedance of the tissue was noticed, on average up to 4.31 times more than the baseline, and no side effects were observed after GS5% infusion. In conclusion, impedance alteration by Glucose solution infusion may focus IRE on tumor tissue and decrease IRE's effects on healthy tissue., This research was supported by the Spanish government (Ministry of Economy and Competitiveness) under Grants RTI2018-094357-B-C21, RTI2018-094357-B-C22 and Carlos III Health Institute under Grant PI17/0048 and also PI21/00440 from the same institution.
Recercat. Dipósit de la Recerca de Catalunya
Publication Artículo científico (JournalArticle)

Development of a catheter-based technique for endoluminal radiofrequency sealing of pancreatic duct

  • Ewertowska, Elżbieta
  • Andaluz, Anna
  • Moll, Xavier
  • Aguilar, Adrià
  • Garcia, Felix
  • Fondevila, Dolors
  • Quesada Diez, Rita
  • Trujillo Guillén, Macarena
  • Burdío Pinilla, Fernando
  • Berjano, Enrique J.
introduction: Endoluminal sealing of the pancreatic duct by glue or sutures facilitates the management of the pancreatic stump. Our objective was to develop a catheter-based alternative for endoluminal radiofrequency (RF) sealing of the pancreatic duct. Materials and methods: We devised a novel RF ablation technique based on impedance-guided catheter pullback. First, bench tests were performed on ex vivo models to tune up the technique before the in vivo study, after which endoluminal RF sealing of a ∼10 cm non-transected pancreatic duct was conducted on porcine models using a 3 Fr catheter. After 30 days, sealing effectiveness was assessed by a permeability test and a histological analysis. Results: The RF technique was feasible in all cases and delivered ∼5 W of power on an initial impedance of 308 ± 60 Ω. Electrical impedance evolution was similar in all cases and provided guidance for modulating the pullback speed to avoid tissue sticking and achieve a continuous lesion. During the follow-up the animals rate of weight gain was significantly reduced (p < 0.05). Apart from signs of exocrine atrophy, no other postoperative complications were found. At necropsy, the permeability test failed and the catheter could not be reintroduced endoluminally, confirming that sealing had been successful. The histological analysis revealed a homogeneous exocrine atrophy along the ablated segment in all the animals. Conclusions: Catheter-based RF ablation could be used effectively and safely for endoluminal sealing of the pancreatic duct. The findings suggest that a fully continuous lesion may not be required to obtain complete exocrine atrophy., This work was supported by the Spanish Ministerio de Economía, Industria y Competitividad under “Plan Estatal de Investigación, Desarrollo e Innovación Orientada a los Retos de la Sociedad” (Grant TEC2014–52383–C3–R) and by the Spanish Ministerio de Ciencia, Innovación y Universidades under “Programa Estatal de I + D + i Orientada a los Retos de la Sociedad" (Grant: RTI2018-094357-B-C21 and –C22). Elżbieta Ewertowska has a Predoctoral Grant (BES-2015–073285) from the Ministry of Economy, Industry and Competitiveness (Government of Spain). Also funding was received from Secretaría de Estado de Investigación, Desarrollo e Innovación.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Pancreatic duct ligation reduces premalignant pancreatic lesions in a Kras model of pancreatic adenocarcinoma in mice

  • Cáceres, Marta|||0000-0002-4100-2542
  • Quesada, R.|||0000-0002-8264-0356
  • Iglesias, Mar|||0000-0002-2274-4671
  • Real, Francisco X.|||0000-0001-9501-498X
  • Villamonte, Maria
  • de Villarreal, Jaime Martinez
  • Pérez, Mónica
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • Moll, Xavier|||0000-0002-2992-9361
  • Berjano, Enrique|||0000-0002-3247-2665
  • Dorcaratto, Dimitri
  • Sánchez Velázquez, Patricia|||0000-0002-7902-3920
  • Grande, L.|||0000-0001-9146-9004
  • Burdío, Fernando|||0000-0003-3038-0086
Pancreatic duct ligation (PDL) in the murine model has been described as an exocrine pancreatic atrophy-inducing procedure. However, its influence has scarcely been described on premalignant lesions. This study describes the histological changes of premalignant lesions and the gene expression in a well-defined model of pancreatic ductal adenocarcinoma by PDL. Selective ligation of the splenic lobe of the pancreas was performed in Ptf1a-Cre (+/ki) ; K-ras LSLG12Vgeo (+/ki) mice (PDL-Kras mice). Three experimental groups were evaluated: PDL group, controls and shams. The presence and number of premalignant lesions (PanIN 1-3 and Atypical Flat Lesions-AFL) in proximal (PP) and distal (DP) pancreas were studied for each group over time. Microarray analysis was performed to find differentially expressed genes (DEG) between PP and PD. Clinical human specimens after pancreaticoduodenectomy with ductal occlusion were also evaluated. PDL-Kras mice showed an intense pattern of atrophy in DP which was shrunk to a minimal portion of tissue. Mice in control and sham groups had a 7 and 10-time increase respectively of risk of high-grade PanIN 2 and 3 and AFL in their DP than PDL-Kras mice. Furthermore, PDL-Kras mice had significantly less PanIN 1 and 2 and AFL lesions in DP compared to PP. We identified 38 DEGs comparing PP and PD. Among them, several mapped to protein secretion and digestion while others such as Nupr1 have been previously associated with PanIN and PDAC. PDL in Ptf1a-Cre (+/ki) ; K-ras LSLG12Vgeo (+/ki) mice induces a decrease in the presence of premalignant lesions in the ligated DP. This could be a potential line of research of interest in some cancerous risk patients.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Preliminary evaluation of the safety and efficacy of glucose solution infusion through the hepatic artery on irreversible electroporation focusing

  • Sarreshtehdari, Amirhossein
  • Burdío, Fernando|||0000-0003-3038-0086
  • López-Alonso, Borja
  • Lucía, Óscar
  • Burdio, José Miguel
  • Villamonte, Maria
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • García Arnas, Félix|||0000-0001-6651-3173
  • Berjano, Enrique|||0000-0002-3247-2665
  • Moll, Xavier|||0000-0002-2992-9361
Due to electrical features of the tissue, such as impedance, which have a significant impact on irreversible electroporation (IRE) function, the administration of glucose solution 5% (GS5%) through the hepatic artery would focus IRE on scattered liver tumors. By creating a differential impedance between healthy and tumor tissue. This study aimed to determine the effects of the GS5% protocol on healthy liver tissue and its safety. 21 male Athymic nude rats Hsd: RH-Foxn1 mu were used in the study. Animals were split into two groups. In group 1, a continuous infusion through the gastroduodenal artery of GS5% was performed to measure the impedance with a dose of 0.008 mL/g for 16 min. In group 2, the animals were divided into two subgroups for infusions of GS5%. Group 2.1, at 0.008 mL/g for 16 min. Group 2.2 at 0.03 mL/g for 4 min. Blood samples were collected after anesthesia has been induced. The second sample, after catheterization of the artery, and the third after the GS5% infusion. All the animals were sacrificed to collect histological samples. The survival rate during the experiment was 100%. A considerable impact on the impedance of the tissue was noticed, on average up to 4.31 times more than the baseline, and no side effects were observed after GS5% infusion. In conclusion, impedance alteration by Glucose solution infusion may focus IRE on tumor tissue and decrease IRE's effects on healthy tissue.