Skip to main content

EFECTOS DE LA ELETROPORACION Y LA ELECTROQUIMIOTERAPIA EN LA DESTRUCCION LOCALIZADA DE TUMORES HEPATICOS EN MODELO PORCINO EXPERIMENTAL

PI21/00440

•
Funding agency name Instituto de Salud Carlos III
Funding agency acronym ISCIII
Program Programa Estatal de Generación de Conocimiento y Fortalecimiento del Sistema Español de I+D+I
Subprogram Subprograma Estatal de Generación de Conocimiento
Call Proyectos de Investigación en Salud
Call year 2021
State Plan 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Beneficiary centre FUNDACION INSTITUTO DE INVESTIGACION SANITARIA ARAGON
Execution centre INSTITUTO DE INVESTIGACION SANITARIA ARAGON

Resultados relacionados

Resultados totales (Incluyendo duplicados): 19
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Liver tissue remodeling following ablation with irreversible electroporation in a porcine model

  • Monleón, E.
  • Lucía, Ó.
  • Güemes, A.
  • López-Alonso, B.
  • Arribas, D.
  • Sarnago, H.
  • Hernáez, A.
  • Burdío, J. M.
  • Junquera, C.
Irreversible electroporation (IRE) is a method of non-thermal focal tissue ablation characterized by irreversibly permeabilizing the cell membranes while preserving the extracellular matrix. This study aimed to investigate tissue remodeling after IRE in a porcine model, especially focusing on the extracellular matrix and hepatic stellate cells. IRE ablation was performed on 11 female pigs at 2,000 V/cm electric field strength using a versatile high-voltage generator and 3 cm diameter parallel-plate electrodes. The treated lobes were removed during surgery at 1, 3, 7, 14, and 21 days after IRE. Tissue remodeling and regeneration were assessed by histopathology and immunohistochemistry. Throughout the treated area, IRE led to extensive necrosis with intact collagenous structures evident until day 1. From then on, the necrosis progressively diminished while reparative tissue gradually increased. During this process, the reticulin framework and the septal fibrillar collagen remained in the necrotic foci until they were invaded by the reparative tissue. The reparative tissue was characterized by a massive proliferation of myofibroblast-like cells accompanied by a complete disorganization of the extracellular matrix with the disappearance of hepatic architecture. Hepatic stellate cell markers were associated with the proliferation of myofibroblast-like cells and the reorganization of the extracellular matrix. Between 2 and 3 weeks after IRE, the lobular architecture was almost completely regenerated. The events described in the present study show that IRE may be a valid model to study the mechanisms underlying liver regeneration after extensive acute injury.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Self-adaptive overtemperature protection materials for safety-centric domestic induction heating applications

  • Pascual, A.
  • Acero, J.
  • Llorente, S.
  • Carretero, C.
  • Burdio, J. M.
Security aspects in the household sphere have become a major concern in modern societies. In particular, regardless of the technology used, users increasingly appreciate a protection system to prevent material damage in the case of human errors or distractions during the cooking process. This paper presents a sensorless method for detecting and limiting overtemperature, unique to induction cooktops, based on their specific features, such as automatic pot detection and load power factor estimation. The protection system exploits the change in the load material properties at certain temperatures, the effect of which may be enhanced by arranging a multilayer structure comprising a low Curie temperature alloy and an aluminum layer. The proposed multilayer load exhibits two differentiated states: a normal state, where the cookware is efficiently heated, and a protection state, above the safety temperature, where the power factor abruptly decreases, limiting the overheating and making the state easily detectable by the cooktop. This method of overtemperature self-protection uses the electronics of conventional induction cooktops; therefore, no other sensors or systems are required, reducing its complexity and costs. Simulation and experimental results are provided for several cookware designs, thereby proving the feasibility of this proposal.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Printed circuit board coils of multi-track litz structure for 3.3 kW inductive power transfer system

  • Narvaez, Alexis
  • Carretero, Claudio
  • Lope, Ignacio
  • Acero, Jesús
This paper presents the optimization procedure of an inductive power transmission (IPT) system which utilizes large size spiral printed circuit board (PCB) coils for high- power transfer. Printed circuit boards for coil assembly provides advantages in the manufacturing process through the use of cost- effective flexible fabrication techniques. Furthermore, this kind of construction offers a low profile device, which is of great interest for applications with space constraints. PCB-based IPT system coils can achieve high energy efficiency by applying litz-structure braiding techniques, as investigated in this work, where the objective was to obtain an optimized balance between the conduc- tion losses and proximity losses associated with the number and dimensions of the traces. Considering the geometrical dimensions and manufacturing constraints, we will proceed to obtain the characteristics of the coil to achieve optimal performance. The estimation of coil losses were in part based on finite element simulations, and the results were conveniently processed with the appropriate mathematical methods. Numerical simulation and experimental results were conducted for validation on a prototype suitable to transfer up to 3.3 kW for a transmitter- receiver distance of 10 cm. In the experimental arrangement, a maximum efficiency in the coils of 93% has been measured, and the overall efficiency of 88% has been reached for the entire IPT system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Preliminary evaluation of the safety and efficacy of glucose solution infusion through the hepatic artery on irreversible electroporation focusing

  • Sarreshtehdari, Amirhossein
  • Burdio, Fernando
  • López-Alonso, Borja
  • Lucía, Óscar
  • Burdio, José Miguel
  • Villamonte, María
  • Andaluz, A.
  • García-Arnas, F.
  • Berjano, E.
  • Moll, Xavier
Due to electrical features of the tissue, such as impedance, which have a significant impact on irreversible electroporation (IRE) function, the administration of glucose solution 5% (GS5%) through the hepatic artery would focus IRE on scattered liver tumors. By creating a differential impedance between healthy and tumor tissue. This study aimed to determine the effects of the GS5% protocol on healthy liver tissue and its safety. 21 male Athymic nude rats Hsd: RH-Foxn1mu were used in the study. Animals were split into two groups. In group 1, a continuous infusion through the gastroduodenal artery of GS5% was performed to measure the impedance with a dose of 0.008 mL/g for 16 min. In group 2, the animals were divided into two subgroups for infusions of GS5%. Group 2.1, at 0.008 mL/g for 16 min. Group 2.2 at 0.03 mL/g for 4 min. Blood samples were collected after anesthesia has been induced. The second sample, after catheterization of the artery, and the third after the GS5% infusion. All the animals were sacrificed to collect histological samples. The survival rate during the experiment was 100%. A considerable impact on the impedance of the tissue was noticed, on average up to 4.31 times more than the baseline, and no side effects were observed after GS5% infusion. In conclusion, impedance alteration by Glucose solution infusion may focus IRE on tumor tissue and decrease IRE’s effects on healthy tissue.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Tumor location on electroporation therapies by means of multi-electrode structures and machine learning

  • Briz, P.
  • López-Alonso, B.
  • Sarnago, H.
  • Burdío, J.M.
  • Lucía, O.
Electroporation is a phenomenon produced in the cell membrane when it is exposed to high pulsed electric fields that increases its permeability. Among other application fields, this phenomenon can be exploited in a clinical environment for tumor ablation therapies. In this context to achieve optimum results, it is convenient to focus the treatment on the tumor tissue to minimize side effects. In this work, a pre-treatment tumor location method is developed, with the purpose of being able to precisely target the therapy. This is done by taking different impedance measurements with a multi-output electroporation generator in conjunction with a multi-electrode structure. Data are processed by means of a vector of independent artificial neural networks, trained and tested with simulation data, and validated with phantom gels. This algorithm proved to provide suitable accuracy in spite of the low electrode count compared to the number of electrodes of a standard electrical impedance tomography device.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

GaN-based matrix resonant power converter for domestic induction heating

  • Guillen, P.
  • Sarnago, H.
  • Lucía, O.
  • Burdio, J. M.
Flexible-surface induction cooktops must operate with a variety of induction heating loads with different behavior and power setpoints to be heated simultaneously. In this context, multi-output inverter topologies aim at achieving independent power management while featuring low power-device count and high power density. However, they suffer from limitations when applying classical modulation strategies to ensure soft switching, which is required to reduce transistor losses and achieve efficient operation. In this scenario, wide band-gap devices reduce switching losses, opening a new paradigm in power conversion where soft switching is not mandatory in order to achieve high efficiency. This paper proposes an implementation of a multi-output resonant inverter based on GaN HEMTs and evaluates various modulation strategies in terms of efficiency under different switching modes. The proposed approach is designed and experimentally validated by means of a 2-coil 2000 W prototype implementation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Electroporation pulse generator for biomedical applications with improved output voltage ripple and reduced bus capacitor

  • Sarnago, H.
  • Burdio, J. M.
  • Lucia, Ó.
Electroporation is a promising cancer treatment based on applying short electric field pulses. In this context, highly versatile pulse generators are required to generate high-voltage low-ripple pulses in the µs range. In the past, several multi-level converters have been proposed to achieve this aim. Achieving constant output voltage and, consequently, electric field is essential to obtain predictable treatments and minimize the risks of tumor relapse. However, significant bus capacitance is required to achieve the required performance, leading to bulky equipment with serious safety implications due to the stored energy. In this letter, a high-performance pulse generator for electroporation is proposed that takes advantage of a multi-level structure with linear voltage regulation to achieve the desired performance with reduced bus capacitance. The proposed converter has been designed and tested experimentally during both laboratory and operation room treatments.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Coupling between cavity resonances and characteristic modes on household appliances

  • Labodía, Miguel
  • Español, Jorge
  • Tesa, Jorge
  • Mediano, Arturo
Home appliances generally comprise a mechanical envelope, or enclosure, of electrically conductive material (steel, aluminum, etc.) that houses electrical and electronic circuits. That envelope typically includes all kind of apertures, openings, holes, slots, windows, etc., to connect—physically and electromagnetically—the external space with its internal space. The performance of that envelope is a key element to comply with surface current EMI/EMC (Electro-Magnetic Interference/Electro-Magnetic Compatibility) regulations for electromagnetic interference, both emissions and immunity. Here, we present a novel theoretical proposal that consists of establishing the mathematical relationship of the coupling between the resonant modes of an internal cavity (RMs) contained in a conductive body and the characteristic modes (CMs) on the external surface of its envelope through the openings that connect those external and internal spaces, and doing so by means of equivalent virtual surface currents located in those openings. The comparative results of simulations and actual measurements of immunity in an anechoic chamber (measurements originally oriented to other purposes) are presented as above-mentioned evidence of resonating modes coupling on the frequency range 40–1000 MHz. However, this theoretical proposal is novel and remains to be developed in greater depth and detail in future works.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Comparative evaluation of different cables for magnetic couplers in inductive power transfer systems

  • Acero, Jesús
  • Lope, Ignacio
  • Carretero, Claudio
  • Sarnago, Héctor
  • Burdío, José Miguel
Copper litz wires are widely used in wireless charging stations of light-duty electric vehicles. This type of cable is specifically mentioned in the SAE J2954 standard. However, details as the number and diameter of strands, or the material of conductors are not mentioned in the standard, which makes room to address some research and innovations. In this work, several alternatives to the traditional copper-litz wires are analyzed. Specifically, aluminum litz wire, copper-clad aluminum litz wire, and copper tubes are considered as alternatives to standard litz wire for the mentioned application. Potential benefits of the considered alternatives could include weight and cost savings. However, these advantages could not be enough to justify a wiring change if the resistance of the power pads increases and, equivalently, the efficiency of the electromagnetic power transfer decreases. For this reason, a model of the parasitic resistance of windings is proposed by combining the analytical ac resistance of two-layered round strands and finite element simulations. This model is used to obtain a figure of merit related with the efficiency of the electromagnetic energy transfer which is used to compare the different cables. Apart from efficiency, thermal behavior, cost and weight are also considered for comparison purposes. As a result, some conclusions about the suitability of each cable with respect to the operating frequency range are extracted.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Dual-Output Extended-Power-Range Quasi-Resonant Inverter for Induction Heating Appliances

  • Sarnago, Hector
  • Burdio, Jose M.
  • Lucia, Oscar
Induction heating technology provides efficient and reliable heating processes that outperform other classical heating methods based on fossil fuels or resistive heating. Among its many industrial, domestic, and biomedical applications, domestic induction heating appliances are a popular choice due to these advantages. This technology requires high-performance and cost-effective inverters that take most of the power devices and the converter topology. Depending upon the desired performance and output-power range, different power converters are employed. However, currently, most platforms rely on the well-known series resonant half-bridge topology. Single-switch topologies offer a cost-effective implementation but are limited to the low-cost low-performance markets due to their limitations in terms of output power and power control. In this context, this paper proposes a high-performance dual-output quasi-resonant inverter for modern induction heating appliances. Unlike state-of-the-art proposals, this converter achieves a full-output-power operating range of up to 3.6 kW. Consequently, it provides a high-performance cost-effective alternative to current implementations. The proposed converter is analyzed in this paper and experimentally verified using a dual-output 3.6-kW induction heating appliance prototype.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Normalized nonlinear impedance boundary condition in anhysteretic magnetic material for eddy current problems

  • Carretero, Claudio
  • Acero, Jesús
  • Burdio, José M.
Numerical simulations of induction heating systems often assume that the properties of the induction load are linear. Thus, its electrical behavior is described by an equivalent impedance which exhibits frequency dispersion but remains independent of the excitation level. Although deriving such solutions is computationally complex, the use of the impedance boundary condition (IBC) provides high-quality results for linear media. This boundary condition replaces the effects of media with rapidly varying fields by a ratio between their tangential components at the surface. However, in typical induction loads, magnetic saturation of the material causes phenomena of dependence of the properties on the current level. The precise formulation of such an IBC can only be performed considering linear media. This paper proposes calculating a nonlinear excitation level-dependent IBC numerically, considering the saturation dependence of the magnetic properties given by a Langevin function BH-loop. A normalized form of the nonlinear IBC will be obtained from the equation governing this type of behavior, thereby reducing the computational cost of the solution. The usefulness of the proposed nonlinear IBC will be validated by comparing it with results obtained from conventional time domain simulations of a typical induction heating system.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

A versatile switched-mode large-signal gan-based low-distortion arbitrary waveform generator

  • Álvarez-Gariburo, Ignacio
  • Sarnago, Héctor
  • Burdío, José M.
  • Lucia, Oscar
In a multitude of industrial and biomedical applications, the need for arbitrary waveform generators is essential, serving the purpose of load characterization and excitation, among others. Historically, these generators have had limitations in terms of voltage, current, and frequency output, primarily related with constraints associated with the power devices and circuit topologies. However, notable advancements in semiconductor technology have introduced a new era, enabling the creation of highly versatile waveform generators capable of superior performance, and extended operational capabilities. In this article, a versatile AWG based on switched modules is proposed. In contrast to the previous ones, whose implementation was based on linear amplifiers, it enables arbitrary waveform generation, higher efficiency, and very low output impedance. In addition, it is also presented as a novelty that the voltage in each of the modules is different, following a digital to analog converter (DAC) structure, which allows us to obtain a lower total harmonic distortion (THD) in the output waveform than with conventional methods. The design will take advantage of wide band gap devices to be able to switch in the MHz range to achieve a high bandwidth. Furthermore, in addition to the design and implementation of a high-performance generator, a comparative analysis between the conventional and the proposed DAC-based modulation pattern is performed based on a comparative analysis of the THD and switching losses.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Optimizing IRE targeting using multi-electrode structure and biomedical multi-output generator

  • López-Alonso, Borja
  • Briz, Pablo
  • Sarnago, Hector
  • Burdio, José M.
  • Lucia, Oscar
Purpose This paper aims to study the feasibility of proposed method to focus the electroporation ablation by mean of multi-output multi-electrode system. Design/methodology/approach The proposed method has been developed based on a previously designed electroporation system, which has the capabilities to modify the electric field distribution in real time, and to estimate the impedance distribution. Taking into consideration the features of the system and biological tissues, the problem has been addressed in three phases: modeling, control system design and simulation testing. In the first phase, a finite element analysis model has been proposed to reproduce the electric field distribution within the hepatic tissue, based on the characteristics of the electroporation system. Then, a control strategy has been proposed with the goal of ensuring complete ablation while minimizing the affected volume of healthy tissue. Finally, to check the feasibility of the proposal, several representative cases have been simulated, and the results have been compared with those obtained by a traditional system. Findings The proposed method achieves the proposed goal, as part of a complex electroporation system designed to improve the targeting, effectiveness and control of electroporation treatments and serve to demonstrate the feasibility of developing new electroporation systems capable of adapting to changes in the preplanning of the treatment in real-time. Originality/value The work presents a thorough study of control method to multi-output multi-electrode electroporation system by mean of a rigorous numerical simulation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Histopathological analysis of growth of implanted VX2 liver tumor

  • Monleón, E.
  • Junquera, C.
  • Baselga, M.
  • López-Alonso, B.
  • Briz, P.
  • Arribas, M.D.
  • Sarnago, H.
  • Burdío, J.M.
  • Lucía, O.
  • Güemes, A.
  • Aramayona, J.
P04 X International Congress of Histology and Tissue Engineering - XXII Congress of the Spanish Society of Histology and Tissue Engineering - X Iberoamerican Congress of Histology. 10-13 September, 2024, Alilcante, Spain. Poster presentations – Session 3 – Tissue Engineering
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Ultrastructural study of rabbit VX2 liver tumor: metastasis and necrosis

  • Junquera, C.
  • Aramayona, J.C.
  • Borja, P.
  • Güemes, A.
  • Baselga, M.
  • Arribas, D.
  • Briz, P.
  • Lucía, O.
  • Burdio, J.M.
  • Monleón, E.
P01 X International Congress of Histology and Tissue Engineering - XXII Congress of the Spanish Society of Histology and Tissue Engineering - X Iberoamerican Congress of Histology. 10-13 September, 2024, Alilcante, Spain. Poster presentations – Session 3 – Tissue Engineering
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Study on effect of electroporation combining high- and low-frequency harmonics

  • López-Alonso, Borja
  • Polajžer, Tamara
  • Reberšek, Matej
  • Sarnago, Héctor
  • Lucía, Óscar
  • Miklavcic, Damijan
The effects of electroporation are highly influenced by the shape of the applied waveform. This waveform shape can modify the transmitted energy and current flow patterns, impacting the electric field distribution, temperature rise among others. These interactions, along with their synergies with electroporation, are being explored across various industrial and research domains. For instance, in the biomedical field, high-frequency waveforms such as nanosecond pulses offer distinct advantages, while in the food industry, controlled temperature increases combined with electroporation are beneficial. However, in the medical field, the effects of combining high-frequency waveforms (in the MHz range) with low-frequency waveforms (in the kHz range commonly used in clinical electroporation) have not been thoroughly studied, though hypotheses have been proposed regarding their potential effects. In this paper, proof of concept of the effect of the combination of two harmonics is presented using three different strategies to investigate new electroporation protocols. To support this study, a specialized electrical and thermal test bench was developed to control and evaluate the feasibility and potential of possible synergy between high- and low-frequency waveforms to electroporation using an in vitro model.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Contribución de congreso (ConferenceOutput)

Treatment of rabbit VX2 liver cancer by irreversible electroporation

  • Monleón, E.
  • López-Alonso, B.
  • Briz, P.
  • Arribas, M.D.
  • Junquera, C.
  • Baselga, M.
  • Sarnago, H.
  • Burdío, J.M.
  • Güemes, A.
  • Aramayona, J.
  • Lucía, O.
P55 X International Congress of Histology and Tissue Engineering - XXII Congress of the Spanish Society of Histology and Tissue Engineering - X Iberoamerican Congress of Histology. 10-13 September, 2024, Alilcante, Spain. Poster presentations – Session 3 – Tissue Engineering
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publication Artículo científico (JournalArticle)

Radiation Pattern Recovery from Tilted Orbital Sampling Measurements via Sparse Spherical Harmonic Expansion

  • Labodía, Miguel
  • Mediano, Arturo
This paper proposes a reconstruction framework for estimating the far-field (FF) radiation patterns of large, heavy, or non-rotatable wireless-enabled systems. The method combines a tilted orbital sampling (ToS) strategy with sparse spherical harmonic (SH) expansion, compressed sensing (CS), and convex optimization (CO), thereby linking a mechanically constrained acquisition scheme with a mathematically efficient recovery process. The purpose of this integration is not only to reduce the number of measurements but also to retrieve the radiation information most relevant to Internet of Things (IoT) devices and bulky equipment that cannot be easily rotated within anechoic chambers. The framework is validated on two representative cases: a canonical half-wave dipole and a commercial Wi-Fi-enabled device. In the latter and more challenging case, accurate reconstruction is achieved with fewer than 30 SH coefficients and using less than 20% of the measurements required by a conventional full-sphere scan, with the normalized root-mean-square error remaining below 5%. Although inaccessible angular regions may be partially uncharacterized, such directions are of minor relevance for the intended operational coverage. The resulting SH-based representation can be seamlessly integrated into ray-tracing propagation simulators and electromagnetic optimization workflows, enabling efficient and application-oriented OTA characterization under realistic chamber constraints.
Dipòsit Digital de Documents de la UAB
Publication Artículo científico (JournalArticle)

Preliminary evaluation of the safety and efficacy of glucose solution infusion through the hepatic artery on irreversible electroporation focusing

  • Sarreshtehdari, Amirhossein
  • Burdío, Fernando|||0000-0003-3038-0086
  • López-Alonso, Borja
  • Lucía, Óscar
  • Burdio, José Miguel
  • Villamonte, Maria
  • Andaluz Martínez, Anna|||0000-0001-8097-8110
  • García Arnas, Félix|||0000-0001-6651-3173
  • Berjano, Enrique|||0000-0002-3247-2665
  • Moll, Xavier|||0000-0002-2992-9361
Due to electrical features of the tissue, such as impedance, which have a significant impact on irreversible electroporation (IRE) function, the administration of glucose solution 5% (GS5%) through the hepatic artery would focus IRE on scattered liver tumors. By creating a differential impedance between healthy and tumor tissue. This study aimed to determine the effects of the GS5% protocol on healthy liver tissue and its safety. 21 male Athymic nude rats Hsd: RH-Foxn1 mu were used in the study. Animals were split into two groups. In group 1, a continuous infusion through the gastroduodenal artery of GS5% was performed to measure the impedance with a dose of 0.008 mL/g for 16 min. In group 2, the animals were divided into two subgroups for infusions of GS5%. Group 2.1, at 0.008 mL/g for 16 min. Group 2.2 at 0.03 mL/g for 4 min. Blood samples were collected after anesthesia has been induced. The second sample, after catheterization of the artery, and the third after the GS5% infusion. All the animals were sacrificed to collect histological samples. The survival rate during the experiment was 100%. A considerable impact on the impedance of the tissue was noticed, on average up to 4.31 times more than the baseline, and no side effects were observed after GS5% infusion. In conclusion, impedance alteration by Glucose solution infusion may focus IRE on tumor tissue and decrease IRE's effects on healthy tissue.