A comprehensive survey on fault tolerance in multiphase AC drives, part 1: general overview considering multiple fault types

  • Gómez Yepes, Alejandro
  • López Sánchez, Óscar
  • González Prieto, Ignacio
  • Durán, Mario J.
  • Doval Gandoy, Jesús
Multiphase drives offer enhanced fault-tolerant capabilities compared with conventional three-phase ones. Their phase redundancy makes them able to continue running in the event of faults (e.g., open/short-circuits) in certain phases. Moreover, their greater number of degrees of freedom permits improving diagnosis and performance, not only under faults affecting individual phases, but also under those affecting the machine/drive as a whole. That is the case of failures in the dc link, resolver/encoder, control unit, cooling system, etc. Accordingly, multiphase drives are becoming remarkable contenders for applications where high reliability is required, such as electric vehicles and standalone/off-shore generation. Actually, the literature on the subject has grown exponentially in recent years. Various review papers have been published, but none of them currently cover the state-of-the-art in a comprehensive and up-to-date fashion. This two-part paper presents an overview concerning fault tolerance in multiphase drives. Hundreds of citations are classified and critically discussed. Although the emphasis is put on fault tolerance, fault detection/diagnosis is also considered to some extent, because of its importance in fault-tolerant drives. The most important recent advances, emerging trends and open challenges are also identified. Part 1 provides a comprehensive survey considering numerous kinds of faults, whereas Part 2 is focused on phase/switch open-circuit failures., Xunta de Galicia | Ref. ED431F 2020/07, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Ministerio de Ciencia, Innovación y Universidades | Ref. RYC2018-024407-I, Ministerio de Ciencia, Innovación y Universidades | Ref. PID2019-105612RB-I00, Junta de Andalucía | Ref. UMA20-FEDERJA-039
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Online control strategy for tolerating resistance asymmetry with minimum copper loss in the full torque range for symmetrical six-phase AC drives

  • Gómez Yepes, Alejandro
  • Abdel-Azim, Wessam E.
  • Shawier, Abdullah
  • Abdel-Majeed, Mahmoud Said
  • Che, Hang Seng
  • Abdel-Khalik, Ayman Samy
  • Ahmed, Shehab
  • Doval Gandoy, Jesús
Multiphase drives exhibit remarkable advantages (e.g., fault tolerance) over three-phase ones. Six-phase drives are particularly attractive, given their moderate complexity and suitability for off-the-shelf three-phase converters. Regarding the stator winding arrangement, the symmetrical one offers superior postfault capabilities in most scenarios. On the other hand, resistance asymmetry in the stator phases or connections may arise due to different causes. The conventional full-range minimum-loss strategy (FRMLS) generates stator-current references under open-phase (infinite resistance) faults so that torque ripple is prevented while minimizing the losses for each torque ( d - q current) value and maximizing the torque range; however, this method is unsuitable for unequal resistances of finite value. This article proposes an FRMLS for setting the current references to reach these goals in symmetrical six-phase drives with any resistance asymmetry. The optimum references are found online depending on the resistances, without lookup tables. The phase currents are individually limited by an iterative algorithm, so that minimum stator copper loss (SCL) is achieved over the maximum admissible torque range. In this manner, unlike the conventional FRMLS, minimum SCL and maximum torque range are attained even for finite resistance imbalance. The currents in phases affected by high resistances are suitably reduced. Experimental results are provided, Xunta de Galicia | Ref. ED431F 2020/07, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00, Ministry of Higher Education, Malaysia | Ref. Scheme FP090-2020, Science, Technology and Innovation Funding Authority | Ref. 37066
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Open-phase fault-tolerant DTC technique for three-level NPC VSI-fed five-phase induction motor drives

  • Chikondra, Bheemaiah
  • Gómez Yepes, Alejandro
  • Al Zaabi, Omar
  • Al Hosani, Khalifa
  • Doval Gandoy, Jesús
  • Behera, Ranjan Kumar
The demand for motor drives based on multiphase machines (MMs) is increasing due to their inherent fault-tolerant capabilities. To achieve satisfactory post-fault operation, a proper fault-tolerant controller is needed. Some direct-torque-control (DTC) techniques have been reported for five-phase induction motor (FPIM) drives under an open-phase fault (OPF). DTC offers simplicity, fast response, and less parameter sensitivity. However, the existing fault-tolerant DTC methods were designed for two-level voltage-source inverters (VSIs). A three-level neutral-point-clamped (NPC) VSI allows greater flexibility in the switching states, lower current and torque ripple, and reduced common-mode voltage (CMV). However, the increased number of switching states requires the design of new DTC methods, able to tolerate OPFs while providing satisfactory performance in various aspects. In this paper, two fault-tolerant DTC techniques are developed for three-level NPC VSI-fed FPIM drives under an OPF. The possible switching states are synthesized with suitable virtual vectors, addressing the dc-link voltage balance, dv/dt, CMV and dc-link utilization. The two methods are compared under an OPF in these terms, as well as regarding the average switching frequency. Comparative experimental results are provided to assess the viability of the developed DTC schemes at steady-state and dynamic conditions, Khalifa University | Ref. FSU-2021-006, Agencia Estatal de Investigación | Ref. RYC2018-024407-I
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Study and active enhancement by converter reconfiguration of the performance in terms of stator copper loss, derating factor and converter rating of multiphase drives under two open legs with different stator winding connections

  • Gómez Yepes, Alejandro
  • Doval Gandoy, Jesús
Multiphase machines offer inherent tolerance to faults such as open converter legs (OCLs), which are especially frequent. Because of this reason, they are particularly attractive for applications where fault tolerance is important, such as offshore wind energy or aerospace, naval and military vehicles. It has been previously shown that, under an OCL, certain stator winding configurations (SWCs) different from star yield smaller stator copper loss (SCL) and larger maximum achievable torque (MAT) than star SWC for the same torque command and machine. This advantage comes just at the expense of a moderate increase in converter rating. However, only the case of single OCL was studied in general. The SCL, MAT and required converter rating for two OCLs are currently unknown for different combinations of phase number, faulted legs and SWCs. Actually, under two OCLs (unlike for one OCL) it may be possible to actively modify the order of the faulted/healthy legs to enhance the performance in these terms, but this possibility has not been studied so far in spite of its potential. This paper addresses the postfault performance of multiphase drives with two OCLs, for various SWCs. The MAT (derating factor), SCL and necessary converter rating are assessed in numerous possible scenarios. The most convenient alternatives are established. Most importantly, in view of the conclusions of this analysis, a novel method is proposed to improve substantially the MAT and SCL by actively altering the connections between the converter and machine terminals. Experimental results with six-phase and twelve-phase setups are provided., Xunta de Galicia | Ref. ED431F 2020/07, Ministerio de Ciencia, Innovación y Universidades | Ref. RYC2018-024407-I, Agencia Estatal de Investigacion | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Overmodulation method with adaptive x-y current limitation for five-phase induction motor drives

  • Gómez Yepes, Alejandro
  • Doval Gandoy, Jesús
Five-phase induction machines are attractive due to inherent benefits such as lower current rating than three-phase ones. On the other hand, ac motor drives often need to operate in the overmodulation (OVM) region, e.g., to increase the maximum speed or to work with reduced dc-link voltage. Most of the existing OVM strategies for five-phase drives are based on injecting low-order harmonics in the no-torque x y plane while avoiding low-order α - β harmonics (at least up to a modulation index of 1.2311p.u. ), so as to prevent the torque ripple associated with the α - β components. However, in practice the x - y impedance is very small, and hence, this approach can easily lead to overcurrent. This article proposes an OVM method for five-phase induction motors that adaptively modifies the injected components so that at each moment the addition of low-order x - y harmonics is favored over α - β ones but without surpassing the maximum current rms of the drive. In case the total stator copper loss (SCL) tends to exceed its rating during OVM in a given scenario, the proposed scheme automatically reduces the x - y injection to keep the SCL at its rated value. Experimental results verify the theory, Xunta de Galicia | Ref. ED431F 2020/07, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00, Agencia Estatal de Investigación | Ref. RYC2018-024407-I
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Discrimination between eccentricity and interturn faults using current or voltage-reference signature analysis in symmetrical six-phase induction machines

  • Gómez Yepes, Alejandro
  • Fonseca, Davide S. B.
  • Antunes, Hugo R. P.
  • López Sánchez, Óscar
  • Marques Cardoso, Antonio J.
  • Doval Gandoy, Jesús
Two common defects in induction machines (IMs) are eccentricity and interturn faults, which should be diagnosed to prevent performance degradation and further damage. A popular fault-detection approach is the current signature analysis (CSA), because of its simplicity and nonintrusiveness. Under closed-loop control, it is combined with analogous voltage-reference (VR) signature analysis (VRSA). However, by using these methods in three-phase IMs, it is difficult to discriminate between these faults, which cause similar symptoms. Multiphase machines provide remarkable advantages such as inherent tolerance to open-phase faults. Six-phase IMs are particularly attractive since they allow adopting three-phase converters. Among them, those with symmetrical spatial arrangement of the stator phases offer superior fault tolerance. Nonetheless, the distinction between eccentricity and interturn failures in these IMs has not been addressed so far. This article studies the discrimination between eccentricity and interturn faults in symmetrical six-phase (S6) IMs by CSA or VRSA. It is shown that, conversely to three-phase IMs and most other multiphase IMs, in S6 ones, these two types of failures can be easily distinguished: interturn faults considerably alter the currents or VRs in the so-called x - y plane, whereas eccentricity leads to current/voltage symptoms only in the α1 - β1 plane. Experimental results confirm the theory., Fondo Europeo de Desarrollo Regional, Fundação para a Ciência e a Tecnologia | Ref. PTDC/EEI-EEE/29494/2017, Fundação para a Ciência e a Tecnologia | Ref. UIDB/04131/2020, Fundação para a Ciência e a Tecnologia | Ref. UIDP/04131/2020, Fundação para a Ciência e a Tecnologia | Ref. UI/BD/153572/2022, Xunta de Galicia | Ref. ED431F 2020/07, Xunta de Galicia | Ref. ED431B 2020/03, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Simple carrier-based PWM for prolonged high dc-link utilization for symmetrical and asymmetrical n-phase AC Drives

  • Gómez Yepes, Alejandro
  • Doval Gandoy, Jesús
Square voltage waveforms enable high dc-link utilization (DLU) in multiphase ac drives. Circulating-current filters were devised to attenuate the harmonics in no-torque low-impedance subspaces. Nonetheless, the square-wave harmonics that generate torque ripple are not reduced. Recently, it was proposed to combine circulating-current filters with a carrier-based pulsewidth modulation (PWM) method, which injects harmonics in no-torque subspaces (attenuated by the filter) of five-phase motors to achieve high DLU, without harmonics associated with torque ripple. The filter allows prolonged high-DLU operation without overheating. Compared with other PWM techniques capable of high-DLU operation (overmodulation), the one proposed for said filters is especially convenient because of its simplicity. However, it is unclear if this PWM method can be extended to machines of any phase number n and winding arrangement (symmetrical or asymmetrical); and if so, the resulting performance is also unknown. This article extends this simple carrier-based PWM strategy to n-phase drives, and evaluates its behavior in terms of DLU, distortion, and computational burden. Symmetrical and asymmetrical winding arrangements are considered. The improvement in DLU, compared with conventional PWM with zero-sequence injection, is considerable. Current distortion is negligible with a suitable filter. The simplicity over other high-DLU PWM techniques is remarkable. Experimental results are provided, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Improvement in dc-link utilization with reduced current and torque deterioration for five-phase drives by combination of circulating-current filters and simple carrier-based PWM based on closed-form expressions

  • Gómez Yepes, Alejandro
  • Doval Gandoy, Jesús
  • Toliyat, Hamid A.
Multiphase drives offer important advantages over three-phase ones. With pulsewidth modulation (PWM), zero-sequence and x-y signals can be injected to enhance dc-link utilization (DLU). For example, in five-phase drives, for given dc-link voltage, the fundamental is raised by 23.1%. For sinusoidally distributed windings, although x-y currents increase losses, torque is unaffected. However, no simple carrier-based PWM methods based on closed-form expressions have been presented for this purpose so far. Most importantly, x-y currents may be unacceptably large, due to the small x-y impedance. This is particularly troublesome when high fundamental voltage is needed continuously. Applying square waveform instead of PWM raises the fundamental from 23.1 to 27.3%. Given the square-voltage distortion, filters with large x-y impedance were devised for this approach. However, some square-waveform harmonics map into the torque-producing plane without attenuation, generating torque ripple. This article proposes to use a simple carrier-based PWM method in five-phase drives combined with a circulating-current filter. The x-y voltages, which see large filter impedance, are exploited to achieve a high DLU similar to previous solutions, but without torque ripple or excessive x-y currents. Guidelines are given for designing the filter when used with the presented PWM strategy. Experimental results verify the proposal, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. DPI2016-75832-R
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

A carrier-based overmodulation strategy with minimum voltage distortion for symmetrical n-phase induction motor drives

  • Medina Sánchez, Martín
  • Gómez Yepes, Alejandro
  • López Sánchez, Óscar
  • Abdel-Khalik, Ayman Samy
  • Doval Gandoy, Jesús
Multiphase machines have significant benefits over their three-phase counterparts. One of them is the possibility of further exploiting the dc-link voltage by injecting non-torquerelated voltage harmonics in the xy planes. This allows reaching higher modulation indices in the overmodulation (OVM) region of pulsewidth modulation (PWM) while avoiding torque ripple in motors with negligible space harmonic effects. The most prominent OVM techniques are those based on the instantaneous minimization of the xy voltage. These methods were devised just for five-phase drives and have the drawback that they lack generality. This article overcomes this limitation by proposing an OVM strategy for symmetrical induction motor drives with any odd phase number n. The proposal achieves the minimum voltage distortion, and consequently, it greatly mitigates the xy current distortion. Indeed, it attains the lowest current distortion compared with the existing techniques. It relies on carrier-based PWM in its design and implementation stages, and accordingly, it is much simpler than previous methods. Furthermore, the inverter switching frequency (loss) is substantially reduced. Theoretical assessments are given for drives with odd n between 5 and 11. The experiments are performed with a symmetrical nine-phase induction motor with a single neutral point, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. PID2022-136908OB-I00, Xunta de Galicia | Ref. ED431F 2020/07, Xunta de Galicia | Ref. GPC-ED431B 2020/03
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

General online current-harmonic generation for increased torque capability with minimum stator copper loss in fault-tolerant multiphase induction motor drives

  • Gómez Yepes, Alejandro
  • Shawier, Abdullah
  • Abdel-Azim, Wessam E.
  • Abdel-Khalik, Ayman Samy
  • Ahmed, Shehab
  • Doval Gandoy, Jesús
This article proposes a current-reference generation method, including current harmonic injection (CHI) for enhancing the torque capability of multiphase induction machines (IMs) with negligible space-harmonic effects, which is useful, e.g., during transient overload in electric vehicles. The admissible torque is increased because the harmonics reduce the phase-current peaks so that the instantaneous peak-current constraint of the drive, usually associated with the converter ratings, is respected. The harmonics are injected in the so-called x−y subspaces of the IM, which do not produce torque, so that no torque ripple is introduced. The optimum harmonics are found online for each load, making it possible to minimize the stator copper loss (SCL) per torque in the entire torque range, ensuring full-range minimum loss (FRML). The method is suitable for healthy operation or open-phase faults and for multiphase machines of any phase number and with either symmetrical or asymmetrical windings. Compared with FRML methods without CHI, higher torque is achieved. Although some techniques were available for increasing the torque capability by CHI, FRML was not attained, laborious off-line optimization was needed, or they were only suitable for specific drives or healthy conditions, unlike the proposal. Experimental results with a symmetrical six-phase IM are provided, Xunta de Galicia | Ref. ED431F 2020/07, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Information Technology Industry Development Agency | Ref. ARP2020.R29.7, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00, Agencia Estatal de Investigación | Ref. RYC2018-024407-I
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

A comprehensive survey on fault tolerance in multiphase AC drives, part 2: phase and switch open-circuit faults

  • Gómez Yepes, Alejandro
  • González Prieto, Ignacio
  • López Sánchez, Óscar
  • Durán, Mario J.
  • Doval Gandoy, Jesús
Multiphase machines are very convenient for applications that require high reliability. In this two-part survey, the state of the art about fault tolerance in multiphase drives is reviewed. In Part 1, an overview including numerous fault types was presented, along with fundamental notions about multiphase drives. Here, in Part 2, the focus is placed on phase/switch open-circuit (OC) faults in particular, which have received the most attention in the literature. Phase OC failures involve OCs in stator phases or in converter-machine connections, and switch/diode OCs are frequently dealt with similarly or identically. Thanks to the phase redundancy of multiphase drives, their operation can be satisfactorily continued under a certain number of OCs. Nonetheless, the procedure to follow for this purpose is far from unique. For given OC fault conditions, numerous fault-tolerant possibilities can be found in the literature, each of them with different advantages and disadvantages. Moreover, a great variety of methods have also been devised to detect and diagnose phase/switch OC failures so that, as soon as possible, the most appropriate fault-tolerance measures are applied. Thus, given the broad literature about tolerance to phase/switch OC faults in multiphase drives, the survey presented here is expected to be of great interest for the research community and industry., Xunta de Galicia | Ref. ED431F 2020/07, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Ministerio de Ciencia, Innovación y Universidades | Ref. RYC2018-024407-I, Agencia Estatal de Investigación (AEI) | Ref. PID2019-105612RB-I00, Junta de Andalucía | Ref. UMA20-FEDERJA-039
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

DC-signal injection for stator-resistance estimation in symmetrical six-phase induction motors under open-phase fault

  • Gómez Yepes, Alejandro
  • Abdel-Majeed, Mahmoud Said
  • Che, Hang Seng
  • Abdel-Khalik, Ayman Samy
  • Ahmed, Shehab
  • Doval Gandoy, Jesús
Multiphase machines are often chosen due to their enhanced fault tolerance. Six-phase ones are especially convenient because they may be fed by off-the-shelf three-phase converters. In particular, those with symmetrical windings offer superior postfault capabilities. On the other hand, estimation of the stator resistance is important for purposes such as thermal monitoring and preserving control performance. Resistance estimation by dcsignal injection provides low sensitivity to parameter deviations compared with other techniques. It has previously been shown that the dc signal can be added in the non-torque-producing (xy) plane of a six-phase machine to avoid the torque disturbances that typically arise in three-phase machines. However, extending this method to the case of an open-phase fault (OPF) is not straightforward, because of the associated current restrictions. This paper addresses dc-signal injection in a symmetrical sixphase induction motor with an OPF. It is shown that, in contrast to healthy operation, the postfault dc injection should be carefully performed so that minimum copper loss, peak phase current and zero-sequence braking torque are achieved. A solution that attains optimum performance in all these aspects simultaneously is proposed. Adapted controller and resistance estimation are also presented. Experimental results confirm the theory, Ministry of Higher Education, Malaysia | Ref. Scheme FP090-2020, Science, Technology and Innovation Funding Authority | Ref. 37066, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Xunta de Galicia | Ref. ED431F 2020/07, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

On the advantages of symmetrical over asymmetrical multiphase AC drives with even phase number using direct controllers

  • Gonzalez Prieto, Angel
  • González Prieto, Ignacio
  • Gómez Yepes, Alejandro
  • Durán, Mario J.
  • Doval Gandoy, Jesús
Multiphase electric drives offer attractive advantages over conventional three-phase systems. Some of the benefits are shared by all multiphase configurations, but the performance can be highly affected by the specific location of the stator windings. While the asymmetrical configuration has been traditionally a popular choice, the symmetrical disposition in even-phase machines has a main advantage: it is possible to generate α – β voltages without any contribution in different x – y subspaces. This article explains and demonstrates this feature for the general case of distributed-winding symmetrical n -phase machines, with n being an even number. Fortunately, direct controllers can benefit from this characteristic by exclusively selecting voltage states with only α – β voltage production. To illustrate this capability, a finite-control-set model predictive control (FCS-MPC) using these special voltage states is also suggested in this work for symmetrical six-phase electric drives. This approach provides a greater simplicity and much less current distortion than in standard FCS-MPC for the asymmetrical configuration. Comparative experimental results confirm the minimal x – y injection of symmetrical configurations thanks to the proposed control actions (i.e., voltage states), Agencia Estatal de Investigación | Ref. RTI2018-096151-B-I00, Xunta de Galicia | Ref. ED431F 2020/07, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Strategy with smooth transitions and improved torque–speed region and stator copper loss for two-level asymmetrical six-phase induction motor drives under switch faults

  • Gómez Yepes, Alejandro
  • Doval Gandoy, Jesús
  • Toliyat, Hamid A.
Asymmetrical six-phase drives are very attractive to obtain fault tolerance. Most faults arise in the power electronics. Two conventional methods to handle switch/diode faults in two-level converters are keeping the corresponding phases open (in two-level multiphase drives) or connecting them to the dc-link midpoint (in two-level three-phase drives) through a bidirectional switch (e.g., triac/relay). However, the former yields larger stator copper loss (SCL) for given torque and smaller maximum torque, because of current constraints; on the other hand, the latter reduces the maximum speed, due to voltage constraints, and has not been considered for two-level multiphase drives. This article presents several proposals to improve fault-tolerant behavior in two-level asymmetrical six-phase induction motor drives. First, to adequately combine and alternate said two approaches in these particular drives, depending on the speed, neutral-point configuration, and faulty legs. In this manner, the SCL-per-torque decreases and the total torque-speed region of the drive is extended, i.e., the maximum torque and maximum speed rise compared with each of the aforementioned conventional strategies. Second, to also turn on/off a switch between stator neutral points for further improvement in this regard. Third, a pulsewidth modulation procedure to ensure smooth transitions between drive configurations. Experimental results confirm the theory., Agencia Estatal de Investigación | Ref. RYC2018-024407-I
Investigo. Repositorio Institucional de la Universidade de Vigo
Publication Artículo científico (JournalArticle)

Effective current limitation for multifrequency current control with distortion-free voltage saturation and antiwindup

  • Gómez Yepes, Alejandro
  • Doval Gandoy, Jesús
In three-phase converters, it is frequently important to control current components other than the positive-sequence fundamental. Adequate voltage saturation and antiwindup (VSA) should also be included to prevent malfunction under output-voltage saturation due to, e.g., large voltage disturbances or dc-link-voltage reduction. A multifrequency VSA technique was recently proposed, based on modifying the current references so that the control output voltage is brought back to within the hexagonal boundary. Thus, it avoids the additional distortion that would arise if the control output surpassed (even partially) the hexagon. However, no current limitation was considered. If the current references demanded by the VSA are saturated, windup of the integrator contained in said VSA scheme may occur. Furthermore, current saturation also causes steady-state overmodulation; then, the actual current differs from that fed back to the control (due to the internal-model-control structure included in the VSA), and hence it is not effectively limited. This article adds current-saturation functionality to the multifrequency VSA by several relevant modifications. Windup of the integrator of the VSA when current saturation occurs is prevented. The actual current is effectively limited to the desired value also when there is steady-state overmodulation. Experimental results with a three-phase permanent-magnet machine are provided, European Regional Development Fund | Ref. DPI2016-75832, Agencia Estatal de Investigación | Ref. RYC2018-024407-I