Skip to main content

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental study of a real-time and highly sensitive fiber-optic porous silicon temperature sensing probe

  • Caroselli, Raffaele
  • Martín-Sánchez, David
  • Prats-Quílez, Francisco
  • Torrijos-Morán, Luis
  • Ponce-Alcántara, Salvador|||0000-0002-7479-8129
  • García-Rupérez, Jaime|||0000-0002-2036-0084
[EN] We report the development of a temperature sensing probe created as a result of the combination of an optical fiber and a porous silicon microcavity (PSMC). After determining the physical parameters of the PSMC to achieve the required porous sensing structure, it was fabricated by electrochemically etching a silicon wafer. A 1-mm(2) PSMC piece was attached to the tip of an optical fiber so that temperature variations can be monitored in real-time exactly on that point. First, the performance of the PSMC sensor probe was characterized in a stable environment as water, obtaining a sensitivity around 110 pm/degrees C and a resolution in the 10-4 degrees C range. Afterward, the temperature transmission dynamics in air environment were studied., This work was supported by the European Commission under Project H2020-644242 SAPHELY, in part by the Spanish Government under Project TEC2013-49987-EXP BIOGATE and Project TEC2015-63838-C3-1-R OPTONANOSENS, and in part by the Generalitat Valenciana under the Doctoral Scholarship under Grant GRISOLIAP/2014/109.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Real-Time and In-Flow Sensing Using a High Sensitivity Porous Silicon Microcavity-Based Sensor

  • Caroselli, Raffaele
  • Martín-Sánchez, David
  • Prats-Quílez, Francisco
  • Torrijos-Morán, Luis
  • Ponce-Alcántara, Salvador|||0000-0002-7479-8129
  • García-Rupérez, Jaime|||0000-0002-2036-0084
[EN] Porous silicon seems to be an appropriate material platform for the development of high-sensitivity and low-cost optical sensors, as their porous nature increases the interaction with the target substances, and their fabrication process is very simple and inexpensive. In this paper, we present the experimental development of a porous silicon microcavity sensor and its use for real-time in-flow sensing application. A high-sensitivity configuration was designed and then fabricated, by electrochemically etching a silicon wafer. Refractive index sensing experiments were realized by flowing several dilutions with decreasing refractive indices, and measuring the spectral shift in real-time. The porous silicon microcavity sensor showed a very linear response over a wide refractive index range, with a sensitivity around 1000 nm/refractive index unit (RIU), which allowed us to directly detect refractive index variations in the 10(-7) RIU range., Funding from Spanish government through grants TEC2015-63838-C3-1-R (MINECO/FEDER, UE) and TEC2013-49987-EXP BIOGATE, from the European Commission through the project H2020-644242 SAPHELY is acknowledged. Raffaele Caroselli also acknowledges the Generalitat Valenciana for funding his grant through the Doctoral Scholarship GRISOLIAP/2014/109.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental study of the sensitivity of a porous silicon ring resonator sensor using continuous in-flow measurements

  • Caroselli, Raffaele
  • Prats-Quílez, Francisco
  • Martín-Sánchez, David
  • Torrijos-Morán, Luis
  • Bandarenka, Hanna
  • Girel, Kseniya
  • Bondarenko, Vitaly
  • Ponce-Alcántara, Salvador|||0000-0002-7479-8129
  • Griol Barres, Amadeu
  • Bellieres, Laurent Christophe
  • García-Rupérez, Jaime|||0000-0002-2036-0084
[EN] A highly sensitive photonic sensor based on a porous silicon ring resonator was developed and experimentally characterized. The photonic sensing structure was fabricated by exploiting a porous silicon double layer, where the top layer of a low porosity was used to form photonic elements by e-beam lithography and the bottom layer of a high porosity was used to confine light in the vertical direction. The sensing performance of the ring resonator sensor based on porous silicon was compared for the different resonances within the analyzed wavelength range both for transverse-electric and transverse-magnetic polarizations. We determined that a sensitivity up to 439 nm/RIU for low refractive index changes can be achieved depending on the optical field distribution given by each resonance/polarization. (C) 2017 Optical Society of America under the terms of the OSA Open Access Publishing Agreement, European Commission through the project H2020-644242 SAPHELY; Spanish government through the projects TEC2013-49987-EXP BIOGATE and TEC2015-63838-C3-1-R-OPTONANOSENS; Generalitat Valenciana through the Doctoral Scholarship GRISOLIAP/2014/109.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publication Artículo científico (JournalArticle)

Experimental Study of the Oriented Immobilization of Antibodies on Photonic Sensing Structures by Using Protein A as an Intermediate Layer

  • Caroselli, Raffaele
  • Garcia Castello, Javier
  • Escorihuela Fuentes, Jorge
  • Bañuls Polo, María-José|||0000-0002-2422-7731
  • Maquieira, Angel|||0000-0003-4641-4957
  • García-Rupérez, Jaime|||0000-0002-2036-0084
[EN] A proper antibody immobilization on a biosensor is a crucial step in order to obtain a high sensitivity to be able to detect low target analyte concentrations. In this paper, we present an experimental study of the immobilization process of antibodies as bioreceptors on a photonic ring resonator sensor. A protein A intermediate layer was created on the sensor surface in order to obtain an oriented immobilization of the antibodies, which enhances the interaction with the target antigens to be detected. The anti-bovine serum albumin (antiBSA)-bovine serum albumin (BSA) pair was used as a model for our study. An opto-fluidic setup was developed in order to flow the different reagents and, simultaneously, to monitor in real-time the spectral response of the photonic sensing structure. The antiBSA immobilization and the BSA detection, their repeatability, and specificity were studied in different conditions of the sensor surface. Finally, an experimental limit of detection for BSA recognition of only 1 ng/mL was obtained, Funding from Spanish government through grants TEC2015-63838-C3-1-R (MINECO/FEDER, UE), TEC2013-49987-EXP BIOGATE, and CTQ/2016/75749-R, and from the European Commission through project H2020-644242-SAPHELY is acknowledged. Raffaele Caroselli also acknowledges the Generalitat Valenciana for funding his grant through the doctoral scholarship GRISOLIAP/2014/109.